Permit CITY OF TIGARD MASTER PERMIT
E . '> COMMUNITY DEVELOPMENT Permit#: MST2019-00309
TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 08/01/2019
Parcel: 2S 103CC 12900
Jurisdiction: Tigard
Site address: 12070 SW WHISTLER'S LOOP
Subdivision: WHISTLER'S WALK NO.2 Lot: 76
Project: Williams
Project Description: Installation and hook up of roof mount 7.13 kW solar system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $21,960.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: 0
Catch Basins: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Bckflw Prevntr: 0
Drywell-Trench Drain: 0 Other Fixtures: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof Top Solar System 7.13kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet:
ALT SF VB R-3 0
Owner: Contractor:
WILLIAMS,VANCE&WENDY GREEN RIDGE SOLAR Required Items and Reports(Conditions)
1 1 1 ec-
TIGARD,OR 97223 TUALATIN,OR 97062
PHONE: PHONE: 503-395-1943
FAX:
Total Fees: $357.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility N titin " enter. Those •=s are set forth in OAR
952-001-0010 through OAR 52-001-0090. You may obtain a copy of the rules or direct questions to OUNC in. . .23 -187 or 1.8.:. 32.2344.
Issued By: _ '\‘.....A......) . Permittee Signa re: . �-% ���.
Call 503.639.4175 by 7:00 a.m.for the next avai ble inspection dat
This permit card shall be kept in a conspicuous place on the job site until comp!,ion of the • oject.
Approved plans are required on the job site at the time of each inspe .•.
•
' Building Permit Application
Residential FOR OFFICE USE ONLY
!IIICl of Tigard Received -,,v---
�,) ,t
g �"°
Date/By: �f- /f .+/ Permit N S/ /� L/ V
w 13125 SW Hall Blvd.,Tigard,OR 972 L V E I VE L) Plan Review /
• Phone: 503.718.2439 Fax: 503.598.1960
Date/By: 7/?' /R Other Permit:
1 i cif,RI) Inspection Line: 503.639.4175 JUL 5 2019 Date Ready/By: 111 / Juris: ® See Page 2 for
Internet: www.tigard-or.gov 2 N. ied/Metho : �j" ' Supplemental Information
• .7.-,A,;,....---- 'df.-4.. ..,,,,,,,,-,, �L 'dif
a} 'I YI' i 7: 1 4 IGD ! I N ll EQ .i,,,D DATA H -'AND 2 FAIT Y WE LING:
ci 0 New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
0 Addition/alteration/replacement ®Other:Solar equipment,materials,labor,overhead,and the profit for the
°; CATEGORY OF ONSTRL 'ION work indicated on this application.
❑ 1-and 2-family dwelling ❑Commercial/industrial Valuation: $21,960
❑Accessory building 0 Multi-family Number of bedrooms:
❑Master builder ®Other:solar Number of bathrooms:
'11111100001101011
JOB1 ITE INFO MATIO AND LOc TICIIY ani u
Total number of floors:
Job site address:12070 SW Whistlers Loop New dwelling area: square feet
City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet
Suite/bldg./apt.no.: Project name: Covered porch area: square feet
Cross street/directions to job site: Deck area: square feet
Other structure area: square feet
RE .T1R;I7111 CO TA:' 1ME -UCS ('KLIS
Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for theSCRIPTION O WORK. t` work indicated on this application.
aur ,i N
Installation and hook up of roof mount 7.13 kW solar system. Valuation: $
Existing building area: square feet
New building area: square feet
illignilligig6 1r.2,,OPERTY O�NNI R ❑ '.PN xNT Number of stories:
_ bpsi . 0 i
Name:Vance Williams Type of construction:
Address:12070 SW Whistlers Loop Occupancy groups:
City/State/ZIP:Tigard,OR 97223 Existing:
Phone:(503)347-3308 Fax:( ) New:
111111111i4P LIC NT '1 CONTACiT PERSOillN^ BUILDING PERMIT `,Ii•••:ES* u
Business name:Green Ridge Solar " Jea*rr MItii e ttlr drdoi
Structural plan review fee(or deposit):
Contact name:Hilary Conway
FLS plan review fee(if applicable):
Address: 19450 SW Mohave Ct.
Total fees due upon application:
City/State/ZIP:Tualatin,OR 97062
Phone:(503)395-1943
E-mail:operationsagreenrtdgepower.com Fax::( )
Amount received:
PTOVOL AIC SPANEL
\STEM FSS*
..
.
CO TRA TOR ,2 ,,,,,� ,
Commercial and residential prescriptive installation of'� rr roof-top mounted Photovoltaic Solar Panel System.
Business name:Green Ridge Solar Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:19450 SW Mohave Ct. Solar Installation Specialty Code checklist.
City/State/ZIP:Tualatin,OR 97062 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(503)395-1943 Fax:( ) State surcharge(12%of permit fee): $21.60
CCB lie.:210450
Total fee due upon application: $201.60
Authorized signature: 4 /ik This permit application expires if a permit is not obtained
within 180 days after it has been accepted as complete.
Print name:Brian Butterfield Date:7/24/19 *Fee methodology set by Tri-County Building Industry
Service Board.
I:Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
A
Electrical Permit Application FOR OFFICE USE ONLY"
rReceived
City of Tigard DateB : Permit#/' 7 ,9—0030 G�
IN r 13125 SW Hall Blvd.,Tigard,OR 97223 r �� / 'Man Review v
= Phone: 503.718.2439 Fax: 503.598.196 E �/ 11`DateB : Related Permit#:
T I G A R D Inspection Line: 503.639.4175 Ready Date/By: Juris: ® See Page 2 for
Internet: www.tigard-or.gov JUL 2 5 2019 Notified/Method: Supplemental Information
'FY&OF OOx fi J D Ra VIEW
0 New construction ❑Addition/alterati0gi
t Please check all that apply(submit 2 sets of plans w/items checked):
' DIVISION
❑Service or feeder 400 amps or more ❑Burldmg over three stones.
❑Demolition ®Other:solar where the available fault current ❑Marinas and boatyards.
CA GOR'y O1001Nsig-Ht IQi[ exceeds 10,000 amps at 150 volts or 0 Floating buildings.
0 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑commercial-use agricultural
amps for all other installations. buildings.
0 Multi-family ❑Master builder ®Other:solar 0
� � Fire pump. 0 Installation of 150 KVA or
s1COB SITE_ 't'lFOliMATION ANO„.I OC,,.'ITJO1! , 0 Emergency system. larger separately derived
❑Addition of new motor load of system.
Job 4: Job site address: 12070 SW Whistlers Loop 100HP or more. ❑°`A”,°`E",°°1-2",°°l-s",
City/State/ZIP:Tigard,OR 97223 ❑Six or more residential units. occupancy.
❑Health-care facilities. ❑Recreational vehicle parks.
Suite/bldg./apt.#: Project name: ❑Hazardous locations. 0 Supply voltage for more than
❑Service or feeder 600 amps or more. 600 volts nominal
Cross street/directions to job site: .
jl, n CIItDULE
Description I Qty. I Each I Total I,r*
New residential single-or multi-family dwelling unit.
Subdivision: Lot 4: Includes attached garage.
Tax map/parcel#:
1,000 sq.ft.or less 168.54 4
i,� „ �� Ea.add'l 500 sq.ft.or portion 33.92 1
; ES„ 'IO$ OF WORT{ , Vis" = Limited energy,residential
Installation and hook up of roof mount 7.13 kW solar system.
(with above sq.ft.) 75.00 2
Limited energy,multi-family 75.00 2
residential(with above sq.ft.)
Renewable E ❑ SePg2
..ROPE 'I`.V O 'N >` Itidlx t1 RNti FT Services or feedersnergy installation,alteratioen,aaned/or relocation
Name:Vance Williams 200 amps or less 100.70 2
Address: 12070 SW Whistlers Loop 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,OR 97223 601 amps to 1,000 amps 301.04 2
Phone:(503)347-3308 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/orEmal: el,Ar e kyk MtoAP_T ,C-00 ,
relocation
Owner installation:This installation is being made on properthat I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
Eft PPL 1CANTl" CONTACT PR Ol Branch circuits—new,alteration,or extension,per panel
A.Fee for branch circuits with
Business name:Green Ridge Solar above service or feeder fee, 7 42 2
each branch circuit
Contact name:Hilary Conway B.Fee for branch circuits without
Address: 19450 SW Mohave Ct. service or feeder fee,first 56.18 2
branch circuit
City/State/ZIP:Tualatin,OR'97062 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(503)395-1943 Fax: :( ) Each manufactured or modular
Email:operations@greenridgepower.com
dwelling,service and/or feeder 67.84 2
Reconnect only 67.84 2
.1,-,,..„__ -i''' - CO T' - TQ 41! li Pump or irrigation circle 67.84 2
-Business name:green Ridge&alar
Address: 19450 SW Mohave Ct.
City/State/ZIP:Tualatin,OR 97062
Phone:(503)395-1943 Fax:( ) to///t Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy
panel,alteration,or extension.
0 See Page 2 2
Each additional inspection over allowable in any of the above
Additional inspection(1 hr min) 66.25/hr
Investigation(1 hr min) 90.00/hr
Email:operations@greenridgepower.comIndustrial plant(1 hr min) 78.18/hr
7(//440
//s O 2( 72,_T. Inspections for which no fee is
CCB Lic.: 210450 Electrical Lic.: CLR-36 rv.Lic.: 267875 spcifi
ecally li %sted hr min) 90.00/hr
LI+~C`TRI4L PRMIT )C'RES, tib
Suprv.Electrician signature,required: Subtotal:
Print name: Brian Butterfield Date: 7/24/19 0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: cr: -/i: TOTAL PERMIT FEE:
/ This permit application expires if a permit is not obtained within 180
�
Print name: 'et4l ate: 1 t-I days after it has been accepted as complete.
* Number of inspections allowed per permit.
I:�Building�Permits�ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/0/COM/WEB
•
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
•
Limited Energy Permit Fees: Renewable Energy Permit Fees:
:W41:0 z: :41 FEE , n ui 6, `u r
Description I Qty Each Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: 5 kva or less 100.70 2
5.01 to 15 kva 1 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva—no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr
charged at an hourly(I hr min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr min)
VM 1&ERCIA, i.,WORK O$LY: ELE CAt FERilhI1,G'{FEES
1v
Fee for each commercial system: $75.00 Subtotal(Enter on Page 1):* Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELCPermitApp_ELR_ERE.doe Rev 06/17/2015
City of Tigard
Building Division
!PI
�■ 13125 SW Hall Blvd,Tigard, OR 97223 RECEIVED
Phone: 503.718.2439 Fax: 503.598.1960 J U L 25 2019
TIGARD Inspection Line: 503.639.4175
www.tigard-or.gov CITY OF TIGARD
3lUILDING DIVISION
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 12 O 7 0 SvJ \N V -1 S e`' Lv o
City: -1--t G�.(. Zip: "J' z 2 3
Owner's Name: V0,4 G 61M.s Date: 7/Z ILO 5
Contractor's Name: E? j AT_ jl a q/ CCB #: j l --5O
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation ❑ Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? CZ No OSSC or ORSC for
design requirements.
Is the wind exposure .� Yes If"Yes", qualifies for
Wind Exposure "C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- �,! If"Yes", qualifies for
C path
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
If"Yes", qualifies for
structures other than
❑ Yes the prescriptive path.
above
❑ No
1
I:Building/Forms/Photovoltaic-Checklist02-01-11.docx
Is the construction
material wood and does Yes
Type of If"Yes", qualifies for
the construction qualify
Constructionas "conventional light ❑ No the prescriptive path.
frame"construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. /1 Yes If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. ❑ If"Yes", qualifies for
Yes the prescriptive path.
❑ No
Is the combined weight tgfYes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance xi Yes
with Section 305.4(3) of If"Yes", qualifies for
111the 2010 Oregon Solar No the prescriptive path.
Code?
n Metal
Single layer If roofing material is
Roofing Check the type of LI of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
of composition
shingle.
Is the roof mounted X Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes", qualifies for
❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:Building/Forms/Photovoltaic-Checklisto2-01-11.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less?
❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directly to inches Maximum 60 inches inches, qualifies for the
standing seam prescriptive path.
metalanels If the width of the panel
p Width of roofing is less than 18 inches,
panels? 18 inches or less
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? ❑ Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 1/2"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
err: fs-
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof Yes the prescriptive path.
surface. ❑ No
3
I:Building/Forms/PhotoVoltaic-Checklist02-01-11.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: M.`c���Z7 n �I
Model Number:
Listing Agency: l�
4
I:Building/Forms/Photovoltaic-Checklist02-01-11.docx
City of Tigard
Tel: 503.718.2439
Location: Inspection Date:
12070 SW WHISTLER'S LOOP, TIGARD, August 14, 2019 at
OR, 97223 11 :17:35 AM
Record Type: Record ID:
Residential - Master Permit MST2019-00309
Inspection Type: Inspector:
299 Final inspection Aaron Cillo-Gobel
Result:
PASS - NoCofO
Comments:
Violation Summary:
Inspector Contractor