Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (14)
v\c-ivC ii i LSC.';, (A. .:) G ,-4.L•,�i ..,\ V - 5®Sim IEx RECEIVED LifeAlarm Fire Alarm Contro s *Igo UL, ULC, CSFM Listed;FM Approved;JUL 2 3 2019 4009 ZDNet NAC Extender for Control with MEA (NYC)Acceptance* CITv nF TIGARD IDNet Communications or Conventional NACs Features BUILDING DIVISION Provides additional notification appliance circuit C I (NAC) capacity with flexible operation modes and ""° II. power-limited design Up to 8 NACs\ • Four, Class B NACs are standard: • Rated 2 A each for conventional reverse polarity 4009 ZDNet 24 VDC notification appliances and providing NAC Extender - ` - multiple operation modes =_ • Can be selected to provide synchronization for Simplex®visible notification strobe flashes o` • Capable of controlling TrueAlert non-addressableIME _ Optional IDNet notification appliances operating with SmartSync _ Channel Repeater .7. 6 two-wire control mode** == I. Input control options: s ' • IDNet addressable communications from a Simplex 2-Wire ZDNet model 4007ES,4010,4010ES,4100ES,or 4100U Fire Communications rss s Alarm Control Panel** Fiber Optic IDNet ,`, • Or from one or two conventional 24 VDC NACs with I Communications Q_r``', multiple output control options ° NAC Control ZDNet communications control benefits: - • Provides status monitoring and individual NAC control �' IDNet Fiber ' ` using a single address per 4009 IDNet NAC Extender Optic Transmitter • Supports IDNet"Device Level"earth fault location WALKTEST operation is available with either 4007ES,4010(shown), input choice 4010ES,4100ES,or 4100U immmigemo Internal 8 A power supply/battery charger: Fire Alarm Control Panel • Charges internal batteries up to 12.7 Ah or up to 18 Ah Fire Alarm Control Panel with Conventional NACs batteries in external cabinet • Provides status monitoring of battery,input power,and 4009 IDNet NAC Extender Connection Reference Drawing earth faults Introduction • Rated 8 A for"Special Application"appliances; including Simplex 4901,4903,4904,and 4906 Series ADA Compliance. Complying with the notification horns,strobes,horn/strobes,and speaker/strobes requirements of ADA(Americans with Disabilities Act) • Rated 6 A for"Regulated 24 DC"appliance power may require more notification appliance power than is Optional 4009 IDNet NAC Extender modules: available within the fire alarm control panel.When IDNet Communications Repeater provides Class B or additional power is required,a Simplex 4009 IDNet NAC • Class A output Extender can provide up to 8 A of NAC power with up to eight,supervised reverse polarity NACs. • IDNet Communications Fiber Optic Receiver/Repeater, available as Class B or Class X Location Flexibility.The 4009 IDNet NAC Extender __---- - can be mounted close to a compatible dedicated host ---- • Four additional Class B NACs,rated 1.5 A for Special panel or can be located remotely for convenient power Application appliances; 1 A for Regulated 24 DC distribution.Multiple operation modes and multiple appliance power connection options further increase location flexibility. • Class A,Two Circuit Adapter Module Additional Information.For additional operation detail UL Listed to Standard 864 and application information,refer to Installation External Accessories Instructions 574-181 and field wiring diagram 842-068. ZDNet communication fiber optic transmitters: * ULC listed model is 4009-9202CA.This product has been approved by the California • Fora applications requiringthe data integrity available State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and pp g y Safety Code.See CSFM Listing 7300-0026:214 for allowable values and/or conditions with fiber optic communications concerning material presented in this document.Accepted for use—City of New York • Available as Class B or Class X Department of Buildings—MEA35-93E.Additional listings may be applicable;contact your local Simplex product supplier for the latest status.Listings and approvals under • Mounts in standard six-gang electrical box Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. External battery cabinet for 18 Ah batteries •;4100U requires revision 11 software or higher for compatibility.4010 requires revision 2 software or higher for compatibility. S4009-0002-14 9/2015 Application and Operation Information IDNet Addressable Communications Compatible. Hardwire Control Applications.For applications Up to ten(10),4009 IDNet NAC Extenders can be where an existing(or new)conventional NAC needs controlled per 4007ES, 4010ES, 4100ES,or 4100U additional power,the 4009 IDNet NAC Extender can be IDNet communications channel;up to five(5)can be controlled directly from the NAC.Either one or two controlled on the 4010 IDNet communications channel. NACs,from either the same,or from different host fire Each output NAC can be individually controlled for alarm control panels,can be connected to control the 4009 general alarm or selective area notification requiring only IDNet NAC Extender output NACs.Multiple control one point address per Extender.Individual Extender selections provide flexible operation. (Refer to page 4 for NACs can also be manually controlled from the host more detail.)Alarms from the host panel will activate the panel.IDNet controlled extenders will inform the host four,4009 IDNet NAC Extender NACs(or optionally, panel of troubles via IDNet communications.4007ES, eight NACs)to extend the alarm. 4010ES,4100ES,and 4100U control panels control using The 4009 IDNet Extender monitors itself and each of its multi-point rules,refer to data sheet S4090-0011 for details. output NACs for trouble conditions,including earth faults. Extenders wired to conventional NACs will Optional IDNet Repeaters.IDNet communications can indicate a trouble by opening the path to the NAC's be repeated with the optional IDNet Repeater Module or end-of-line resistor,but retaining the ability to respond to with the optional Fiber Optic Receiver Module.Up to 100 alarms.Individual troubles are also annunciated by LEDs of the IDNet channel points can be repeated once(refer to located on the 4009 IDNet NAC Extender main circuit pages 3 and 5 for details). Repeated IDNet communications board. (Refer to page 7 for more diagnostic information.) also support the"device level"earth fault location utility of the host panel. Product Selection Standard Models Model Description 4009-9201** 4009 9202CA" 120 VAC input 4009 IDNet NAC Extender with 4,Class B NACs and 8 A power supply 4009-9301 240 VAC input *ULC listed model ""4009-9201 has been seismic tested and is certified to IBC and CBC standards as well as to ASCE 7 categories A through F, requires battery brackets as detailed on data sheet S2081-0019 Optional Modules (for on-site installation) Model Description Additional four point NAC module, rated 1.5 A Special Comments 4009-9807 Application appliances; 1 A for Regulated 24 DC appliance One maximum power, Class B 4009-9808 Dual Class A adapter(for two NAC outputs) Select as required(4 maximum) 4009-9809 IDNet Repeater,output is Class A or Class B 4009-9810 Select either an IDNet Repeater or a Fiber Fiber Optic Receiver I Class B Optic Receiver as required;one transmitter 4009-9811 Class A(ZDNet),Class X(fiber) can connect to one receiver 4009-9805 Red Applique for door Select if required 2975-9801 Beige trim 2975-9802 Semi-Flush Trim Kit 1-7/16"wide(78 mm), use if required for Red trim semi-flush installations Battery Selection (select battery size per system requirements) Model Description Comments —* 2081=9272 6.2 Ah Battery, 12 VDC Two batteries are required,24 VDC 2081-9274 10 Ah Battery, 12 VDC 2081-9288 12.7 Ah Battery, 12 VDC operation Requires external battery cabinet,two 2081-9275 18 Ah Battery, 12 VDC batteries are required,24 VDC operation External Accessories (select per system requirements) Model Description 4090-9105 Comments ZDNet Fiber Optic Class B operation Mounts in six-gang electrical box, refer to 4090-9107 Transmitter Class X operation page 4 for mounting details 4009-9801 External battery cabinet for up to 18 Ah batteries, beige 16-1/4"W x 13-1/2"H x 5-3/4"D (413 mm x 343 mm x 146 mm) 4081 Series End-of-Line Resistor Harnesses;see data sheet S4081-0003 for details 2 S4009-0002-14 9/2015 T •ical IDNet Connection Example Typical IDNet compatible devices (Refer to individual devices for actual wiring requirements,some wiring is not shown.) rT ( ) C IDNet addressable communications channel, .4_,/shown Class B(Style 4) Output NACs,four standard, Conventional NAC operation(horns) — eight with expansion option 0 "R-A----Select conventional ""` or SmartSync 4007ES,4010,4010ES, = operation per NAC 4100ES(shown),or 41000 _ _ y Fire Alarm Control Panel — o C-3f A N IANe NAG FKTEN]ER.s ,. SmartSync operation(horns and strobes) 4009 IDNet NAC Extender with s V =°°-tr-7_ optional internal IDNet Repeater Conventional NAC ,f,73_, operation(strobes) J i 7I / o. Repeated ZDNet Channel: 11111111111111up to 100 devices maximum on repeater output, iL: 250 devices total on IDNet Channel "—" IDNet devices and additional 4009 ZDNet NAC Extender(s) NOTE: Up to ten(10)4009 IDNet NAC Extenders may be connected per 4007ES,4010ES,4100ES, or 4100U ZDNet channel, up to five(5)on the 4010 IDNet channel. IDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Typical Fiber Optic System Connections Two fiber cables,3000 ft Output NACs 4090-9105,Class B (914 m)maximum distance '' (Style 4)Output Fiber meze IIIIIIVIIIINII IIIlI11IIIIIIN / —► Optic Transmitter S e .a-a; lll 7 i i IDNet addressable communications .4"--- channel Class B(Style 4)or Class A (Style 6),Class Bshown ;,,„_-, •i- ._g.-. .I on repeater output,250 devices total on IDNet Channel 4007ES,4010(shown), Four fiber cables,3000 ft 4010ES,4100ES,or 41000 (914 m)maximum distance Fire Alarm Control Panel _—_c- i i �► 24 VDC power for 11111111411 fiber optic transmitters 4090-9107,Class A(Style 7) I N. Output Fiber Optic Transmitter 4009 ZDNet NAC Extenders with optional internal IDNet Fiber Receivers Output NACs NOTE: Up to ten(10)4009 ZDNet NAC Extenders may be connected per 4007ES,4010ES,4100ES, or 41000 IDNet channel, up to five(5)on the 4010 ZDNet channel. ZDNet communications can be repeated only once(can pass through only one series connected repeater or one fiber optic receiver). Fiber optic transmitters connect to only one receiver in a 4009 IDNet NAC Extender. 3 S4009-0002-14 9/2015 Hardwire Control Connection Information SmartSync Notification Appliance Control NAC Input Selections. The 4009 IDNet NAC The TrueAlert Notification Appliance product line Extender can be selected to: includes addressable and non-addressable operation. • Track input NAC operation or to provide a locally Non addressable models are available with 2-wire SmartSync operation or conventional 4-wire operation. generated code,selectable per NAC input • If selected for local coding,NAC outputs can be either The following details apply to use with the 4009 IDNet Temporal Coded or 60 Beats/min March Time Coded, NAC Extender one code selection per extender(input NACs must be on • TrueAlert non-addressable models with SmartSync continuous with Alarm) operation allow audible notification to be separately • Additionally,NAC outputs can be selected to provide controlled over the same wire pair that controls visible the Simplex strobe synchronization signal.This signal notification will synchronize the flashes of synchronized strobes but • 4009 IDNet NAC Extenders can be selected to provide will be ignored by free-run strobes and audible devices. SmartSync operation whether controlled by IDNet (Strobes are for operation by noncoded NACs.) communications or conventional NACs NAC input to NAC output control can be selected for • IDNet control allows output NACs to be individually standard and optional NACs per the following table: selected for conventional or SmartSync operation Conventional NAC Output Operation Options • With NAC input control,all output NACs are selected Input A B C for either conventional or SmartSync operation NAG 1 NACs 1 &2,5&6 NACs 1-4 NACs 1-8 • Refer to data sheet S4009-0003 for TrueAlert NAC 2 NACs 3&4, 7&8 NACs 5-8 None Addressable operation details,contact your local SmartSync NAC Output Operation Simplex product supplier for further information on Input NAC Control Function specific TrueAlert notification appliances NAC 1 Strobe Control NAC 2 Horn Control All NAC outputs(1-8) Hardwire Control NAC Connection One-Line Reference Diagram Up to eight(8)output NACs total;hardwire control can be selected to map NAC inputs to different combinations of NAC outputs depending on system requirements NAC 1 input (see Note 1) L " \ \ AlConventional NACs 6 ► r--) (---1 With hardwire control, e-i NAC outputs are all ► Output ca iov nnc exrenxa - o p conventional or all ___ ---iiii NACs SmartSync operation mimiim 4009 ZDNet NAC _ J1 Extender l ® 1 Fire Alarm Control Panel with Conventional NACs SmartSync operation i i Class A operation,either mode,requires NAC 2 input 4009-9808 Dual Class A Adapter (optional,see Note 1) To additional 4009 ZDNet NAC Extenders(up to four(4), ` 4009 IDNet NAC Extenders per NAC);see Note 2 Notes: 1.For separate audible and visible output NAC control,or SmartSync NAC output operation,two(2)input NACs are required. NAC 1 is"on-until-reset"and NAC 2 is"on-until-silenced." 2.To synchronize strobe flash outputs for up to four(4)4009 IDNet NAC Extenders,use the synchronized strobe output from a Synchronized Flash Module(4905-9914 for Class B operation,4905-9922 for Class A operation)or, if available,from a NAC selected to provide synchronized strobe flash output. NOTE:DO NOT USE a NAC selected for SmartSync operation for this function. Refer to Installation Instructions 574-181 for additional information and application guidance 4 S4009-0002-14 9/2015 4009 IDNet NAC Extender S•ecifications 120 VAC Input(4009-9201) 3A @ 102-132 VAC,60 Hz Input 240 VAC Input(4009-9301) 1.5A @ 204-264 VAC,50/60 Hz Ratings Hardwire Control from External Conventional reverse polarity operation NACs, Input Requirements 5 mA maximum; 16 to 33 VDC Total Rating 8 A,Special Application appliances 6 A, Regulated 24 DC appliance power Standard NACs 2 A each,Special Application or Regulated 24 DC appliance power Optional NACs 1.5 A each,Special Application appliances (requires 4009-9807) 1 A each,Regulated 24 DC appliance power Special Application Simplex non-addressable horns,strobes,and combination horn/strobes and Output Ratings pp speaker/strobes(contact your Simplex product representative for compatible Appliances appliances) p p Regulated 24 DC Power for other UL listed appliances; use associated external synchronization Appliances modules where required Strobe Operation Up to 33 strobes per NAC can be synchronized;output NACs configured for Si Smplex synchronized strobe operation are synchronized to each other Auxiliary Output 500 mA @ 24 VDC nominal Optional Modules Ratings Input Power 70 mA @ 24 VDC,system supplied IDNet Input, One Address Maximum distance from ZDNet source is 2500 ft(762 m) IDNet Repeater Repeated IDNet output for up to 100 devices(total IDNet devices not to exceed Module 250 per channel) (4009-9809) IDNet Output Specifications Maximum distance to farthest device is 2500 ft(762 m) Total distance including"T-taps"is 10,000 ft(3048 m) Class A loop maximum distance is 2500 ft(762 m), no"T"taps Fiber Optic Receiver Modules Input Current 4009-9810,Class B,65 mA @ 24 VDC,system supplied 4009-9811,Class X,80 mA @ 24 VDC,system supplied IDNet Output Specifications Same as those for Repeater Module(see above) Fiber Optic Transmission Distance 3000 ft(914 m)maximum General (LED status indicators are listed on page 7,dimensions and mounting details are on page 6) Operating Temperature 32°to 120°F(0°to 49°C) Operating Humidity Range 10%to 90%RH from 32° F to 104°F(0°C to 40°C) Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Fiber O•tic Transmitter S•ecifications Input Voltage 18.9-32 VDC from compatible listed fire alarm supply Input Current 4090-9105,Class B,30 mA @ 24 VDC 4090-9107,Class X,35 mA @ 24 VDC Multimode,graded index,50/125pm,62.5/125 pm, 100/40 pm,or 200 pm Fiber Optic Gonneetfons emit-aft Tyre ST connectors requirements 4090-9105,Class B operation,two fiber cables required 4090-9107,Class X operation,four fiber cables required Module Size(with mounting bracket) 6-13/16"W x 3-3/4"H x 1-1/8"D(173 mm x 95 mm x 29 mm) Green LED flashing=transmit On-board Status Indicators Red LED flashing=receive Separate red LED on 4090-9107=Class X receive Communications Simplex IDNet Fiber Optic Transmission Distance 3000 ft(914 m)maximum Wiring Connections* Terminal blocks for 18 AWG(stranded)to 12 AWG(solid) Operating Humidity 10%to 90%RH from 32°to 104°F(0°to 40°C) Operating Temperature 32°F to 120°F(0°to 49°C) *Metric wire equivalents: 18 AWG=0.82 mm2; 12 AWG=3.31 mm2 5 S4009-0002-14 9/2015 4009 IDNet NAC Extender Mounting and Module Placement Information 16-1/4"(413 mm) •ICabinet depth r4-1/4"(108 mm)-I a10-29/32"(277 mm) O ' Door,5/8" • 8 0 ®i I o o i_ (16 mm)thick , [ I''-1 I_I I _r_I " ®® o 1-71-17171 f=1=1 _I® 8 0 05K534 Offillaail Optional Class A adapter modules 4009-9807 Additional Four 13-1/2" apt point module(shown with 0 Class A adapters) A © Exposed cabinet (343 mm) \. I I dimension for--so rr�l C System Module / 0 ®l fl fl semi-flush mount rI \\\ 1"(25.4 mm), (Fiber ew IDNet repeater or J 1-3/8"(35 mm)with or nail mounting for schol or nail holes 8 ® � optic receiver I semi-flush trim ��r 8 _®ill ® ®luu 0 L 1 I 1 6 04 1 I' 12"(305 mm) 0.1I I "1 I _ Battery location,no conduit entry or wiring in I I this area(12.7 Ah battery outline shown) I 1 ' 1 O I i P, 1 OI , 2 - I 1 Semi-flush trim option Non-power limited wiring area(AC input) 1-3/16"wide(30 mm), ----1" 3/8"(9.5 mm)thick 77.4 Wall surface reference for semi-flush mount, NOTE: Recommended conduit entrance varies with module selection. Refer to general installation instructions 574-181,specific module installation instructions, and to field wiring diagrams 842-068 before locating conduit entrance. 4009 IDNet NAC Extender Cabinet with Door Detail -- - - _ OPttonat red applique - — (4009-9805) y 0s ;, 4009 IDNet" NAC EXTENDER Simplex 6 S4009-0002-14 9/2015 4090-9105/9107 IDNet Fiber Optic Transmitter Mounting Information Surface mount box: --.4, Simplex model 2975-9217 (ordered separately) • • • • • • Flush mount masonry box: c= =. c c - c use 6-gang box, RACO#960,2-1/2"deep I (64 mm),or RACO#965,3-1/2"(89 mm) LI - • • -• • - • • deep,or equal(supplied by others) I to til O u "illitlai Flush mount ganged oxes) .O ' use 6-gang box, 1-1/2"(38 mm Jr.; ] IP minimum depth;six, RACO#400 "or equal, (supplied by others) � � � = ® O O " ;OSS rariani 1114:_%, gr . Jd / o ° ° ° 0 0 IDNet fiber optic transmitter: 4090-9107,Shown,Class A(Style 7)output 4090-9105,Not shown,Class B(Style 4)output INSTALLATION NOTE: Fiber optic cable bend radius should be 2"(51 mm) R minimum,or per Manufacturer's specification. o o o o o o Six-gang blank cover plate Mulberry Metal Products 97156 or equal(by others) Service Dia•nostic Features LED Status Indicators are provided for the following: • Each NAC(standard and optional)has a dedicated Power-up Self-Diagnostics.Upon power up,the 4009 IDNet NAC Extender tests each module and yellow LED that: performs earth fault diagnostics. Trouble conditions are — During supervision provides a slow flash to indicate communicated to the host control panel and are also a short circuit condition and a fast flash to indicate displayed on diagnostic status LEDs in the 4009 IDNet an open circuit NAC Extender.When connected via IDNet — During an alarm,the LED follows the NAC output communications,detailed status information is available at the host. When controlled with conventional NAC (on steady or flashing with coded output) inputs,common troubles are signaled by providing a • Four, general status yellow LEDs provide nine polarized open circuit that disconnects the NAC wiring separate indications listed in priority of urgency.As a from its end-of-line resistor but still allows a reversed trouble is eliminated,any remaining trouble(s)will polarity alarm to be received. then be indicated until the 4009 IDNet NAC Extender Door Mounted Reference Label.The 4009 IDNet is returned to normal operation. NAC Extender has a detailed programming and • AC power status is indicated by a green LED that is diagnostic label inside the front door that provides a quick on when AC is normal.During low AC(brownout) reference for both installation and checkout. conditions or with no AC,the LED is off.Additional power and battery status is indicated by the general status LEDs. 7 S4009-0002-14 9/2015 4009 IDNet NAC Extender Current Calculation Chart Step 1. Calculate Basic Extender Battery Requirements(minus NAC loads) Panel, NAC Options,and Auxiliary Power(underlined model numbers are optional modules) Model Descript ion Supervisory Actual Alarm Current Actual Alarm Current Supervisory 4009-9201 120 VAC input Basic Panel 85 mA 85 mA 185 mA 185 mA 4009-9301 240 VAC input 4009-9807 Additional Four Point NAC 40 mA + 40 mA + 4009-9808 Dual Class A Adapter(no additional current) — — — Auxiliary Power Output (500 mA + (500 mA maximum) maximum) +[Al] Basic Panel Supervisory Current =[SI] Basic Panel Alarm Current =[A2] Step 2. Calculate IDNet Output Module and Device Current(if used) 4009-9809 IDNet Repeater 70 mA 70 mA 4009-9810* Fiber Optic Receiver,Class B Select one per 65 mA + Extender 65 mA + 4009-9811* Fiber Optic Receiver,Class X 80 mA 80 mA IDNet Devices(connected to Repeater or Receiver above), Total devices 0.7 mA each,maximum of 100 + Total devices 0.7 mA each x 0.7 mA each +— x *Note: IDNet Fiber Optic Transmitter IDNet Module Supervisory Current [S2] = current is supplied from the host fire alarm control panel IDNet Module Alarm Current =[A3] Maximum Available Current =8 A* Step 2. Calculate Available NAC Current Subtract Auxiliary Power Output -[Al] Subtract ZDNet Module Current -[A3] *8 A for Special Application Appliances;6 A for Regulated 24 DC Appliances Available NAC Current =[A4] Step 3. Calculate Actual NAC Loading (Limited to Available NAC Current per Step 2.) NAC Type NAC Circuit# NAC Alarm Current Circuit 1 + Standard Panel NACS,2 A maximum per NAC Circuit 2 + Circuit 3 + Circuit 4 + Circuit 5 + Optional Four Point NAC Module, 1.5 A maximum Special Application rating, Circuit 6 + 1 A maximum Regulated 24 DC rating,per NAC Circuit 7 + Circuit 8 + Total Actual NA - tp 4.CaTcuTate Total Supervisory Current Total Supervisory Current=Basic Panel Current[SI]+ZDNet Module Current[S2]_ Step 5. Calculate Total Alarm Current Total Alarm Current=Basic Panel Current[A2]+ IDNet Module Current[A3]+Actual NAC Current[A5]=I TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited. 13;®S i m p 1 Ex Tyco Fire Protection Products• Westminster,MA•01441-0001•USA S4009-0002-14 9/2015 www.simplex-fire.com ©2015 Tyco Fire Protection Products.All rights reserved All specifications and other information shone were current as of document revision date and are subject to change without notice. ®Simplex TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation AudibleNisible Notification MEA (NYC)Acceptance* with Horn and Synchronized Flash, Non-Addressable Features Audible/visible (AN) notification appliances with -.. —f efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements(refer • to important installation information on page 3) 'e • Rugged,high impact,flame retardant thermoplastic housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to provide: • Horns that are controlled separately from strobes on the 17. ��" same two-wire circuitkr4„.„ . , • "On-until-silenced"and"on-until-reset"operation on the same two-wire pair • SmartSync horn activation of Temporal pattern,March Time pattern(at 60 BPM),or on continuously • Strobe appliances on the same circuit operating at a synchronized 1 Hz flash rate • Class B operation requires connection to a compatible nc NAC or to SmartSync Control Module Y Smarts - - (SCM)4905-9938 Wall and Ceiling Mount A/Vs • Class A operation when connected to the 4905-9938 Descri•tion SCM or with 4100U series fire alarm control panel NACs Multi-Candela TrueAlert A/Vs with horn and Wall mount A/Vs features: synchronized strobe provide convenient installation • Wiring terminals are accessible from the front of the to standard electrical boxes. The enclosure designs are both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection. Since each model can be inspection,and testing selected for strobe intensity output,on-site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA(stairwells,small Wall mount AN are a one-piece assembly rooms,highly reverberant areas,etc.) (including lens)that mounts to a single or double gang,or Optional adapters and wire guards: 4"square standard electrical box. The cover can be • Wall mount A/V adapters are available to cover surface quickly removed(a tool is required)and covers are mounted electrical boxes and to adapt to Simplex® available separately for color conversion. 2975-9145 boxes • UL listed red wire guards are available for wall or Ceiling mount A/Vs install using standard 4"electrical ceiling mount A/Vs boxes. Color choice is determined by model number. Visible notification appliance(strobe): Strobe Intensit Selection • 24 VDC xenon strobe;intensity is selectable as 15,30, During installation,a selection plug at the back of the 75,or 110 candela with visible selection jumper secured housing determines the desired strobe intensity.An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Audible notification appliance Section 13144.1 of the California Health and Safety Code.See CSFM Listing ppance (horn): 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current,24 VDC electronic horn with harmonicallydocument.Accepted for use—City of New York Department of Buildings—MEA35-93E. Refer to page 2 for listing status of wire guards.Additional listings may be applicable; rich sound output suitable for either steady or coded contact your local Simplex product supplier for the latest status.Listings and approvals operation(Temporal or 60 BPM March Time pattern) under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. • UL listed to Standard 464 S4906-0002-6 11/2014 Strobe Application Selection SmartSync Two-Wire Control Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code:BOCA, while the strobe remains flashing. The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, reflections can be seen from one location,synchronized and 4100U Fire Alarm Control Panels(refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of • 4009 IDNet NAC Extender(refer to data sheet random flashing. The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE"Lettering Description 4906-9127 Red White Wall 4906-9129 White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 4906-9128 White 15, 30, 75,or 110 candela;operates with SmartSync two-wire Red control 4906-9130 Ceiling White Red Wall Mount A/V Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D 4905-9940 White surface mounted boxes (136 mm x 133 mm x 41 mm) depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4'°D (200 mm x 130 mm x 70 mm) Optional Sound Damper;package of 20;field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA NOTE:After Sound Damper installation, measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description SmartSync Control Module with Class B or Class A output; mounts in 4" Dimensions 4905-9938 (102 mm)square box;refer to data sheet S4905-0003 for (102 details 4"x 1/0"x x 3 D mmx105 mm 32mm) Replacement Covers for Wall Mount A/Vs 4905-9994 Red cover with white"FIRE"lettering Dimensions 4905-9995 White cover with red"FIRE"lettering 3 H x 2"W x D (1300 m mm x 127 mm x x 3 388 mm) Wire Guards and Ceiling Mount A/V Adapter Model Description 4905-9961 mensions Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"HDx 6-1/16"W x 3-1/8"D * or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927" Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate,required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) *UL listed by Space Age Electronics Inc. 2 S4906-0002-6 11/2014 A/V S•ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC;see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C);10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC50 mA --- 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA at other voltages —--- 284 mA 24 VDC 57 rnA88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference Surface or Semi-Flush Mountin• cfm C_T Mounting is compatible with single gang,double gang,and o 0 4"(102 mm)square boxes, ( 1 o r 1 r . ` 1-1/2"(38 mm)deep,by others _ 1 IMPORTANT!WALL MOUNT Cpl: �'�p� i ��7 INSTALLATION HEIGHT REFERENCE Optional 4905-9838 • —— Sound Damper,field attached to attenuate sound 5 to 6 dBA Bottom of lens h is either even U with,or slightly Electrical Wiring access hole .� 1 u. ` O above bottom box outline r. '/ _ of compatible �� i�iM•=a� ., 1• - �d in Es Smar sync operation g .,'' /1 I O K7 w ' i Mounting Holes: m�,a°a /ti ..I 4"square(4) NFPA 72 requires 80"(2.03 m) ell■ Single gang(2) that the entire lens minimum 1,______W „am.-- IP Transparent housing �I v Double gang(3) be not less than ■ I 80"and not greater than 96"above the finished floor and lens assembly Intensity selection plug,accessible only from rear of housing; Iis I F [1 A 1E factory setting is 15 cd JJllll • Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-6 11/2014 Ceiling Mount AN and Guard Installation Reference Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 01-1/2"(38 mm)minimum depth required for surface mounted electrical box Four mounting clamps included,two each side ctil „p Fe Ceiling reference, f, LC ® flush mounted box, ' �,® A:II War5KiArt Ili Optional 4905-9915/-9916 Adapter, ,� . ..m, recommended for surface mounted box Wiring terminals are Optional 4905-9927 • j located behind the housing Red Wire Guard r I F Alt LE 0 End View IStrobe intensity viewing slot - „ — St ` -, r Intensity selection plug, accessible only from rear of lens housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference c /7-2975-9145 Box. with Optional Adapter Skirt �®� / and Optional Wire Guard (� Surface mount conduit and " O box shown for reference L ° 4"(102 mm)square /III _-F r t .. - O - box profile, 1-1/2" ® (} (38 mm)deep OO Optional f� c-7----__ 4905-9961 --jj Wire Guard I t2AN -2---- - it-Rsi-- It._#t V�--- ME / 4905-9931 Adapter Plate r Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; 4905-9931 Adapter Plate (shown here for reference only, 4905-9940,White(conduit knockouts can be used on other mounting options) are provided on all four sides) • TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). ELSi m p 1 Ex Tyco Fire Protection Products• Westminster, MA•01441-0001•USA S4906-0002-6 11/2014 www.sim Alex-fire.corn ©2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. 5SimplEx TrueA/ert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; Visible Notification Appliances with Synchronized Flash; MEA (NYC)Acceptance* Non-Addressable, SmartSync Operation Compatible Features 0lx Visible only(V/O)24 VDC notification appliances _; 9 � � � 4 with high output xenon strobe, available for wall or ceiling mount: �.. • Intensity is selectable as 15,30,75,or 110 candela with visible selection jumper secured behind strobe housing • Operation is compatible with ADA requirements(refer , " to important installation information on page 3) 4E FIRE *14 • �' Polarized input allows connection to compatible reverse polarity, supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output Wall Mount Strobes and provides controlled inrush current • Rugged,high impact,flame retardant thermoplastic , � , I RE housings are available in red or white with clear lens • Listed to UL 1971 and ULC S526 ' �T k. ' j' { ``'�, Strobes provide synchronized flash for use with: } • Simplex®fire alarm control panels with NACs selected to provide strobe synchronization or SmartSync Ceiling Mount Strobes two-wire control Descri•tion • 4009 IDNet NAC Extenders Multi-Candela TrueAlert synchronized strobes • Separate strobe Synchronization Modules that are provide convenient installation to standard electrical available for Class B or Class A operation boxes. The enclosure designs are both impact and vandal • Separate SmartSync Control Modules(SCMs)that resistant and provide a convenient strobe intensity selection. Since each model can be selected for intensity provide Class B or Class A output from conventional NAC inputs output,on-site model inventory is minimized and changes Strobe housings provides flexible, eas and encountered during construction can be easily convenient semi-flush or surface wall mounting: accommodated. • Rear of housing does not extend into box Wall mount strobe housings are a one-piece assembly (including lens)that mounts to a single or double gang,or • Wall mount strobes easily mount to single gang,double 4"square standard electrical box. The cover can be gang,or 4-inch square outlet box quickly removed(a tool is required)and covers are • Ceiling mount strobes mount to single gang boxes available separately for color conversion. Wall mount strobe features: Ceiling mount strobes install using standard single gang • Wiring terminals are accessible from the front of the electrical boxes. Color choice is determined by model number. housing providing easy access for installation, inspection,and testing Strobe Intensit Selection • Covers are available separately to convert housing color --- �a�� seketioiz plug atthe back oft�ie housing determines the desired strobe intensity. An Optional adapters and wire guards: • Wall mount strobe adapters are available to cover attached flag with black letters on a highly visible yellow bacsurface mounted electrical boxes and to adapt to side of the strobe alllens.the selected intensity to be seen at the p side of the lens. Simplex 2975-9145 boxes • UL listed red wire guards are available for wall or Strobe Application Reference ceiling mount strobes* Proper selection of visible notification is dependent on occupancy,location,local codes,and proper applications * Refer to page 2 for guard listing.This product has been approved by the Califomia State of:the National Fire Alarm Code(NFPA 72),ANSI 1 17.1;the appropriate model building code:BOCA, Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing 7125-0026:316 for allowable values and/or conditions concerning ICBO,or SBCCI;and the application guidelines of the material presented in this document.Refer to page 2 for listing status of wire guards. Additional listings may be applicable;contact your local Simplex product supplier for the Americans with Disabilities Act(ADA). latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S4906-0001-5 11/2014 Synchronized Strobes SmartSync Control Sources Multiple Strobes. When multiple strobes and their SmartSync two-wire control is available from: reflections can be seen from one location,synchronized • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible distraction of and 4100U Fire Alarm Control Panels(refer to individual product data sheets for more information) random flashing.These multi-candela strobes are synchronized over a two-wire circuit when connected to • 4009 IDNet NAC Extenders(refer to data sheet compatible NACs,to compatible Synchronized Flash S4009-0002) Modules,or to SmartSync Control Modules. • SmartSync Control Module(SCM)Model 4905-9938 (refer to data sheet S4905-0003) SmartSync Two-Wire Control Additional SmartSync compatible notification Some applications desire the audible notification appliances include separate horns and combination appliances to be capable of being silenced before the horn/strobe notification appliances. alarm condition is reset(on-until-silenced)while the visible notification appliances are kept activated until the alarm condition is reset(on-until-reset). SmartSync operation mode provides this function using a single circuit(two-wire operation). Product Selection Multi-Candela Visible Notification Appliances (Strobes) Model Mounting Housing Color "FIRE"Lettering Description —l► 4906-9101 Red White Wall 4906-9103 White Red Multi-candela strobe with intensity selectable as: 4906-9102 Red White 15,30,75,or 110 candela;synchronized flash rate; SmartSync two wire control compatible 4906-9104 Ceiling White Red Wall Mount Strobe Adapters Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm) 5-3/8"H x 5-1/4"W x 1-5/8"D 4905-9940 White deep surface mounted boxes (136 mm x 133 mm x 41 mm) Total depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Ceiling Mount Strobe Adapter Model Description Dimensions 4905-9910 Surface Mount Adapter Plate;zinc plated; required for mounting to 4-7/8"x 3-1/8"x 0.060"D handy box;not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Synchronization Modules(refer to data sheet S4905-0003 for additional information) Model Description Dimensions 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with in/out 18 AWG(0.82 mm2)wire leads,rated for 2AN4C,a 1-3/8"x 2-7/16"x 13/16" 4905-6022-- Pr 5mAIorPower (35mmx62mmx20mm) 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4"x 4-1/8"x 1-1/4"D 4"(102 mm)square box (102 mm x 105 mm x 32 mm) Replacement Covers and Guards Model Description Dimensions 4905-9992 Red cover with white"FIRE"lettering I 4905-9993 White cover with red"FIRE"lettering For Wall mount strobes 5-1/8"H x 5"W x 1-1/2"D (130mmx127mmx38mm) 4905-9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with (154 mm x 154 mm x 79 mm) semi-flush or surface mounted boxes 6 1/8"x 4-3/8"x 2-7/8"deep 4905-9926* Ceiling mount (156mmx111 mmx73mm) *UL listed by Space Age Electronics Inc. 2 S4906-0001-5 11/2014 Strobe S•ecifications Wall Mount or Ceiling Mount, Common Specifications Rated Voltage Range Regulated 24 VDC;see Note 1 below Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%, non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Reference RMS Currents 18 VDC 53 mA 84 mA 165 mA 224 mA at other voltages ' 24 VDC 40 mA 63 mA 124 mA 168 mA HuDimensions (with lens) 4-3/4"15 d x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Housing Ceiling Rating per30 cd 75 cd 110 cd Mount Strobe Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Reference RMS Currents 18 VDC 67 mA 111 mA 207 mA 281 mA at other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA NOTES: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971, Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage. (RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference, Surface or Semi-Flush Wall Mounting /c____Th c_im c____Th o 0 / l Mounting is compatible with \ o ( \ (i single gang,double gang,and ( 4"(102 mm)square boxes, ° a� 1-1/2"(38 mm)deep,by others o A �•� 7, 0 IMPORTANT!WALL MOUNT INSTALLATION HEIGHT REFERENCE // 1 Bottom of lens A,\/A1 MB END is either even O O Q 0P %^`�, O with,or slightly Electrical Wiring access hole �O` 1• J = above bottom box outline —410 CI © ' `1 /c_— / of compatible Wiring terminals ��0 bit 01 o )° boxes r, Mounting Holes: mw�� 4"square(4) (2.03m) ® NFPA 72 requires 80" ,1�-n.l - Single gang(2) that the entire lens minimum NISI Double gang(3) be not less than 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection '' plug,accessible only from rear of housing; (15_ 1 % A nfactory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0001-5 11/2014 Ceiling Mount Strobe Installation Reference / Handy box, 1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others /' Also can be attached to boxes A /./ mounted to drop ceiling T-bar with 0 0 clips(ERICO No.512 or equal) 0 4905-9910 Adapter Plate,required for /surface mount with handy box unless 0 1'/ using the 4905-9926 wire guard / i____ I I / "" "" r"'„,�' - � ,., Ceiling mount strobe I I'I ��� j� La i I I Optional 4905-9926 wire guard it ;l with mounting plate �lk'` Strobe intensity li 'kk..; oi 94�� viewing slot i- I Intensity selection plug, m accessible only from rear of lens 1 housing;factory setting is 15 cd 1 — Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 0 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard moon Surface mount conduit and -,- 0 box shown for reference 'gra ==mo4"(102mm)square il- l�I i�lie." m"�` ' box profile, 1-1/2” t 7".. ...yri___ II�'LI�LI�I�II S II (38 mm)deep 1 l., 1 IialI_ I��h I o I Optional O 4905-9961 IPAL---_____1111111111. Wire Guard `_- _ I Strobe 41 _ FIRF ll� 1 —•� , 4905-9931 Adapter Plate I I Optional Surface Mount Adapter dapter Skirt, 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling Code are registered trademarks of the National Fire Protection Association(NFPA). ®S i m p I Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0001-5 11/2014 www.simplex-fire.com ©2014 Tyco Fire Protection Products.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice. 5Simplex System Accessories UL Listed* 4081 Series End-of-Line Resistor Harnesses Features For use as Class B end-of-line resistor: • Connect these resistor harnesses where end-of-line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end-of-line resistor requirements UL Listed to Standard 864 Product Selection 9-1/2" (241 mm) Model Reference Number Description** 4081-9001 733-892 2.2 kc2, 1/2 W 4081-9002 733-893 3.3 kS2, 1 W 4081-9003 733-896 4.7 kS2, 1/2 W 4081-9004 733-886 6.8 kS2, 1/2 W 4081-9005 733-984 1.8 k12, 1/2 W 4081-9006 733-890 560 S2, 1 W 4081-9007 733-891 1.2 kat, 1 Wir ctaw(13 733-894 101(12, 1/2 W 4081-9009 733-912 20 S2, 1 W • 4081-9010 733-973 1 kS2, 1 W 4081-9011 733-974 100 52, 1/2 W 4081-9012 733-985 22 kS2, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081-9013 734-086 4.99 kS2, 1/2 W, ± 1% (full size except for lead length) 4081-9014 734-092 2.4 k52, 1/2 W 4081-9015 734-093 1.5 kc2, 1/2 W 4081-9016 734-1.49 150 k.(1, 1/2 W 4081-9017 734-171 3.9 ks2, 1 W 4081-9018 734-168 10 kS2, 1 W Overall Length Approximately 9-1/2"(241 mm) **±5%tolerance except as noted. Wire Length 7"(178 mm)± 1"(25 mm) Wire Size 18 AWG (0.82 mm2) Insulation 600 V, black Leads Stripped 0.5"(13 mm);tinned Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing *This product was not approved by ULC,FM,MEA(NYC),or CSFM as of document revision date.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4081-0003 7/2004 Tyco,Simplex,and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries. Simplex Tyco Safety Products Westminster• Westminster,MA•01441-0001•USA S4081-0003 7/2004 www.tycosafetyproducts-usa-wm.com 2004 Tyco Safety Products Westminster.All rights reserved.All specifications and other information shown were current as of document revision date and are subject to change without notice.