Loading...
Report atMITSUBISHI L 2 ".. ELECTRIC P-SERIES COOLING & HEATING SUBMITTAL DATA: PKA-A18HA4 & PUY-A18NHA4 (-BS) 18.000 BTUM WALL-MOUNTED AIR-CONDITIONING SYSTEM Job Name: Location: Date: • Purchaser: Engineer: Submitted to: For DReference DApproval DConstruction System Designation: Schedule No.: •tw1 )Ety Indoor Unit:PKA-A18HA4 f (1 E ' j 0 Outdoor Unit PUY-A18NHA4(-BS) GENERAL FEATURES •Wall-mounted indoor unit for residential and commercial applications •Shiny-white–exterior plastic;compact design •Quiet operation—both indoor and outdoor units •Self-check function—integrated diagnostics •Limited warranty:five years parts and seven years compressors UNIT OPTION o Standard Model PUY-A18NHA4 o Sea Coast (BS) Model PUY-A18NHA4-BS OPTIONAL ACCESSORIES Indoor Unit o Mini Condensate Pump(SI3100-230,230V) o L-Connector Pipe(PAC-SC84PI;for left side unit piping installation) Outdoor Unit o Drain Pan(PAC-SG63DP) o Drain Socket(PAC-SG61 DS) o Three-pole Disconnect Switch(TAZ-MS303) o Wind Baffle(WB-PA1) ❑Air Outlet Guide(PAC-SG58SG) o Mounting Base(DSD-400N) o Mounting Pad(ULTRILITE1) o Wall-mounting Brackets(CWMB1) Controller Options o Wireless Wall-mounted Remote Controller Kit(MHK1)' ❑ Portable Controller(MCCH1)* o Outdoor Air Sensor(MOS1)* 'See Submittal for information on each option. ❑ Wired Wall-mounted Controller(PAR-21MAAU) o M-NET Adapter(PAC-SF81 MA) Fen (WC-7�i�AD) _.. o MST ST fortultdtIpie-temoteControMerAdapterdes4 ❑ CN32 Connector for Remote On/Off(PAC-715AD) ❑ Remote Temperature Sensor(PAC-SE41TS) ❑ Remote Operation Adapter-Display and On/Off(PAC-SF40RM) o Remote Operation Adapter-Display and On/Off(PAC-SF40RM) o Hand-held Wreless Remote Controller(PAR-FL32MA;req.PAR-FA32MA-E) o Wreless Signal Receiver Module(PAR-FA32MA-E) o Lockdown Bracket for Hand-held Controller(RCMKP1CB) IOU R I o Control/Service Tool(PAC-SK52ST) K SEACOAST PROTECTION • Extemal Outer Panel:Phosphate coating+Acrylic-Enamel coating • Fan Motor Support:Epoxy resin coating(at edge face) • Separator Assembly;Valve Bed:Epoxy resin coating(at edge face) • Screws(used outer side):Zinc nickel coating 5pm+ Polyvinylidene chloride coating "Blue Fin"treatment is an anticorrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.. Specifications are subject to change without notice. ®2013 Mitsubishi Electric US,Inc. SPECIFICATIONS: PKA-A18HA4 & PUY-A18NHA4 (-BS) Cooling* Indoor Unit Rated Capacity 18,000 Btu/h MCA 1 A Minimum Capacity 8 000 Btu/h Blower Motor(ECM) 0 33 F.L.A. SEER 15.3 Btu/hM/ Blower Motor Output 30 W EER 8 0 Btu/h/W Airflow(Lo-Mid-Hi) 320-370-425 Dry CFM Total Input 2 240 W 290-335-380 Wet CFM Air Filter Polypropylene Honeycomb . Sound Pressure Level(Lo-Mid-H) 36-40-43 dB(A) SH*Rating Conditions per Standard 0 68 9 pe Moisture Removal 5.2 pt./h Cooling I Indoor.80°F(27°C)DB/67°F(19°C)WB Cooling I Outdoor.95°F(35°C)DB/75°F(24°C)WB DIMENSIONS UNIT INCHES/MM W 35-3/8/898 Electrical Requirements D 9-13/16/249 Power Supply 208/230V, 1-Phase,60 Hz H 11-5/8/295 Recommended Fuse/Breaker Size .15 A Weight 29 lbs./13 kg Voltage External Finish Munsell No.1.0Y 9.2/0.2 Indoor-Outdoor S1-S2 AC 208/230V Field Drainpipe Size O.D. 5/8"/16 mm Indoor-Outdoor S2-S3 DC±24V OPERATING RANGE Outdoor Unit Compressor DC Inverter-driven Twin Rotary Indoor Intake Air Outdoor Intake Air MCA . 13 A Temp. Temp. MOCP 20 A Maximum 95°F(35°C)DB 115°F(46°C)DB Fan Motor(ECM) 0 35 F.L.A. Coolin 71°F(22°C)WB Sound Pressure Level g Minimum 67°F(19°C)DB 0°F**(-18°C)DB Cooling 48 dB(A) 57°F(14 C)WB **With optional wind baffle accessory installed.If not installed, DIMENSIONS INCHES/MM the minimum temperature will be 23°F(-5°C)DB. W 31-1/2/800 D 11-13/16+7/8/300+23 H 23-5/8/600 Weight 89 lbs./40 kg External Finish Munsell No.3Y 7.8/1.1 Refrigerant Type R410A Refrigerant Pipe Size O.D. Gas Side 1/2"/12.7 mm Liquid Side 1/4"/6.35 mm Max.Refrigerant Pipe Length 100'/30 m Max.Refrigerant Pipe Height Difference 100'/30 m Connection Method Flared Notes: Specifications are subject to change without notice. S 2013 Mitsubishi Electric US,Inc. ' DIMENSIONS: PKA-A18HA4 (-BS) 15-3/16 387 7-112 192 - Topside Unit: inch(mm) III i en-iiiii�iiiiii�-I i INN it 1 MI Mr �.nMI--MU iiiil-;iiiii NMI.'II -- '-- —•. .—— Mount board 23-9/16(599) Front side7 Right Ode 1� 'mil 1,„.„, 1,. A D.'ride -1/6 27-1/16(688) 6-1/16(155) k9-13/16(249) �I 3/16(5) (55) 35-3/8(898) Knock out hole left piping w for right Piping Front side(Gree open) Sleeve (Odds:wed locally) Through hole /�, .. s= 1.4 d 1(d me)/8 ez 485-080) -13 I?1 — - ,_,..±__I — Terminal dock for ledoorbuldcor eonnedig line - , M'-'llTen.i.6odifornmersorelYN tion)IlimlIllIllIlIll e -1 ., Terminal block for lM MA-remota controller �k•fBe r , (ony PKA-A-NA models) 17-15116(4/17)Gas Pipe 65/8(10 Emergency operation switch 21-3/16(539)Liquid pipe 6-3/18(156) (coolingmealing) 24(810)Drain hose 7-3116(184) Vine auto Under side e•ration le • DEFROST/STAND BY lam• 24-1/18(812) Fs TIMEMBI wit •i Retl'gerant Liquid pipe 1/4F($6.35) Piping Gas pipe 1/2F(012.7) 111- ___ '_l =-= i;i�lil Knockouthale ^ -� .�N� Drain hose ¢518(�16)0.D 1n ck out Pinp r., manual , Knock out hole Receiver - C for loser piping B Center measurement hole¢3/32(62.5) 4-/65/16(9) F m Bolt hole Mount board .,: -"r 8 im E El 88 E N Indoor unit outline P¢3/16(48.1) ^�N. ..A 33- F. 22 3a'� 15 it m^ Tapping g'ss R- g ,, n .f3` .,�ss , ff,s g screw hole d Fd �r S 2 30� '= n<bdsd= 6:5".1.a i__ 7 a .,-._ `2 _ 13/16(21.8) 516(16 :u= 1 4165 4-9/16(116) _ _ 5(128.5) 617(1881 ��� I 6(1Nig53.5) 7((1E41) I 20.5) 41/e(2e�s3) I\ 9-1/16(231.5) s1sn6(zs3s) �_R.U11 I �`S Wall hol - �^ o -' 10.3/4(273.2) left rear ^ : n-2 Knod000l hole to o —•n frog EON Y 34r gPng m 3 hrwPMg ,� C 3��- -3M•12.3/7&70.91g1 pit�3 3 Knockout hole for piping —'1\ Required space(Indoor unit) 121•111111 a (mm) $ 7n61z5) lir56)1! ' ' a_ : ■ armler m -• 1 C 8 ) l0 /� a 7.-, $I i,Min.1.31(32(50) Air outlet 1! ciali 111O11 J ifirdill $- Mi(.6'/8 NI in.5-7/8(150) /4 f I 8 220 A v 1-11/16(43) III II MI B • Specifications are subject to change without notice. ®2013 Mitsubishi Electric US,Inc. r • DIMENSIONS: PUY-A18NHA4 (-BS) A 400<15-25/32> N el Unit:mm(inch) N .347.5<13-11/16 33<1-5/16>drain hole V Air intake CO v Ali el .,_ _ 1iir __I A co I 7 1 Air intake b 0 M 45.4<1-25/32> I A el Air discharge °f - ••' 40<1-9/16> V (V 18<23/32> M 23<29/32> Service panel 22<7/8> Service panel for charge plug f 2••22.2<7/8> - // Handle/ IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 1/2 conduit hole Connection for liquid pipe III IIII I I IIII II III 111111111 I I IIII II N \ FLARE X6.35<va> A IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIco N A IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII th r- C.I CD II111111111111111I11111111111111111 A V g A IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII Q ,— 8 111111111111111111111111111111111111 ;i iii1-, v 1111111111111111111111111111111111110 N =-- -- o — —Connection for gas pipe 144<5-21/32> FLARE yS12.7<1/2> 150<5-29/32> Service port 183<7-7/32> 287.5<11-11/32> Installation bolt pitch 500<19-11/16> 69<2-23/32> • y 800<31-1/2> FOUNDATION BOLTS Clearance space around the outdoor unit 1,,\Min.100mm<3-15/16>as long as Please secure the unit firmly Tac no obstacle is placed on the with 4 foundation M10<W3/8>bolts. & rear and light-and-left sides (Bolts,washers and nut must `—' N:\27of the unit be purchased locally.) �/ KFoundation bolt height ME C> .( ). yin nn 1. 1: Min.350mm<13-25/32> M gr FOUNDATION./ _ /////// N V B •1 -- x B �: ro ` * g� Min.500mm<19-11/16> I Min.100mm<3-15/16> PIPING-WIRING DIRECTION Piping and wiring connection can 2 sides should be open in the right,left and rear side. be made from the rear direction only. Minimum installation space for outdoor unit •1 In the place where short cycle tends to occur,cooling and heating capacity and power consumption might get lowered 10%. Air outlet guide(optional)will help them improve. •2 If air discharges to the wall,the surface might get stained. ItMITSUBISHI ELECTRIC rfillu�: CERTIFIED., COOLING & HEATING .,._:thria,,,,,.,,TAf3 Nc. s. Live Better NHSsUrall Ona240 US 3400 Lawrenceville Suwanee Rd cu,go Suwanee,GA 30024 Tele:678-376-2900•Fax:800-889-9904 Intertek Toll Free:800-433-4822 www.mehvac.com FORM#PKA-A18HA4-PUY-A18NHA4(-BS)-201302 Specifications are subject to change without notice. q 2013 Mitsubishi Electric US,Inc.