Loading...
Plans (88) REGFIVED JUL 3 2019 CITY CF ICA:RD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987Pgmail.com Contractor: Jon Erickson, 503-730-9220 ion.eveniobsPgmail.com CCB 162397 )PEKE COPY Scope of Work— Repair Decks CITY OF TIGARD • Replace perimeter joists with PT REVIE D FOR CODE COMPLIANCE • Repair joist and soffit dry rot Approved: ] • :tipb.vb� ti ,; OTC: [ ] • Replace 42" guardrail and infill to comply withq IBC multi-family code Permit#: ( pat,)9--O0 Lc J Address: 1&"c ,s‘,,, 1 )9 Suite#: By; 41 Date: -7^ ) _ File Location: Fountains Deck Permit Plans REVISED.pptx VALIDITY OF PERM F THE ISSUANCE OF A PERMIT BASED ON CONSTRUCTION DOCUMENTS AND OTHER DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM 7/3/19 Fountains at Summer-field - Deck Building Plans REQUIRING THE CORRECTION 1 OF ERRORS. OSSC 105.4 Typical Deck Construction and Size — 102 SF < Brick Col. 114.5" > 15 x 11.5 'F-- Imbedded 6x6 PT ri 4.---- 4x4 PT Posts A LE < 2 x 8 PT blocking between joists attached with 1 Three 16D 3-1/2"n HDG < ><----->< ) Ref: 2014 Oregon Structural 43" 15" 56.5" Specialty Code-Table 2304.9.1-29 Blocking supports Simpson Rim joist attached to 2"x8" Joists 16" OC J 1 Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG --"—> posts in this position. See 1 Beam^' 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty ^ Tension Ties- page 337 Code-Table I N 2304.9.1-29 1 ,-i House-Brick exterior < 43" Scale- 12"/increment 7/3/19 Fountains at Summerfield - Deck Building Plans 2 • Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" Resurfacing material 3/4" exterior plywood decking U, 'o E CE 00 x N Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing '/" plywood soffit Scale—1" increment .tea.. 7/3/19 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT Simpson DDT2Z \ Attach lateral joist with 8 SDS 1.5 screws � 1 %" x 6" Machine Bolt DTT2Z supports 1800 lb. HDG with nuts and '' ' tension load. Meets IBC washers Code for multi-family deck co 'o guardrails. x, E Refer to attached Simpson °C catalog - Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment 7/3/19 Fountains at Summerfield - Deck Building Plans 4 . . . Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive A _...1 Wide Screw SDWS 4", * ---2"-----TT Railing 2 x 4 TKC three in mid span 7' 1111 2 3/8"TL. Two per betel./ end, I Cap Rail —Trex attached to Railing with L Ili" exterior adhesive. Railing Support 4,7., cri 2 x 4 TKC . o o_ o Attached to I— _ o 0_ r.i Railing and sr Installation of •cr x Posts with ‘zr balasters and rails adhesive and per mfg installation Simpson , instructions. Strong Drive Wide Screw SDWS 4", 1 2 3/8"TL. Railing 2 x 4 TKC Railing Infill - DecKorator aluminum ____. V 2.75" space balaster 3/4" x 32". 0 0. Spacing 3.75" DecKorator Scale 1" increments • 0 CodeCompliance — Research Report Iliiiiiiiiiii CCRR-0161 7/3/19 Fountains at Summerfield -Deck Building Plans 5 of 5