Report (56)
w3Lkv,2 • 2A OFFICE COPY RECEIVED APR - J 2019 CITY OF IRIARD BUILDING DIVISION Power On PERLO CONSTRUCTION JAGUAR LAND ROVER DEALER FIRE ALARM SYSTEM SUBMITTAL General: Perlo Construction 16101 SW 72nd Avenue, Suite 200 Portland, OR 97224 Architect: Mildren Design Group, PC 7650 SW Beveland Street, Suite 120 Portland, OR 97223 Owner: Jaguar Land Rover 10125 SW Washington Square Tigard, OR 97223 Submitted by: On Electric Group 1709 SE 3rd Ave Portland, OR 97214 CCB #ONELEGI851Q3 Job # 180416 C0-1111 et 0 Si 1 1 ri r'-'r."1 4"".ow ;"fri-r n TECH S • ES Making a Daily Difference Product Data Submittal Booklet Jaguar Land Rover Fire Alarm System Project #: 302-FN-H0441 Submittal Date: September 13, 2018 Project Manager: Gene Durnin Electronic Security Project Engineer: Bryan Duffel Fire Alarm & Life Safety Building Automation 503-228-8522 I www.convereint.com EQUIPMENT LIST Head End Equipment Item Part# Manufacturer Description 1 BPS10A Edwards 10 Amp Booster Power Supply 2 1064G Edwards FACP, Grey, 64-Point Loop 3 SA-232 Edwards 10 System RS-232 Interface Card 4 RLCD Edwards Remote Annunciator 5 SSU00625 Space Age Rolled Drawing Storage Box 6 TG-7FS TelGuard Cellular Communicator Field Devices Item Part# Manufacturer Description 7 SIGA-270 Edwards Intelligent Manual Pull Station, Single Action 8 SIGA-CC1S Edwards Intelligent Signal Control Module with Sync 9 SIGA-CRH Edwards Intelligent Control Relay, High Current 10 SIGA-CT1 /-CT2 Edwards Intelligent Single/Dual Input Modules 11 SIGA-HRD Edwards Intelligent Heat Detector, Fixed Temp/Rate of Rise 12 SIGA-PD Edwards Intelligent Photoelectric Smoke Detector 13 SIGA-SB Edwards SIGA-Series Standard Detector Base 14 SIGA-SD Edwards Intelligent Duct Detector Notification Devices Item Part# Manufacturer Description 15 G1 F-HDVM Edwards Horn/Strobe, White, Fire, Wall Mount 16 GIF-VM Edwards Strobe, White, Fire, Wall Mount Battery information is subject to availability at time of installation and not presented here. Sampling tube lengths for duct detectors to be coordinated with mechanical vendor. F z w 2 a_ 5 c( Lu 0 z w 0 Q w E-_)VVA _r;3(',,131,,q l� Power Supplies and Accessories qt. „. DS , , ,.... ,_ ,,„ „, viikt, Ziac Remote Booster %I 1 ''ii`t3 iiiii,,,, iiiiiiSliIiiiii 1111,; ,, , ''w. Power Suppliesal, ..-31- BPS6A, BPS1OA MEA 476-91-E 1111-10 :t. Vol.13 t10!.i{il1 "illillll! � 1/ L lllll� // iNsN sMa IwT 7300-1657: 0229 Overview Standard Features The Booster Power Supply(BPS)is a UL 864,9th Edition listed • Allows for reliable filtered and regulated power to be installed power supply. It is a 24 Vdc filtered-regulated,and supervised where needed unit that can easily be configured to provide additional notification • Cost effective system expansion appliance circuits(NACs)or auxiliary power for Mass Notification/ • Provides for Genesis and Enhanced Integrity notification ap Emergency Communication(MNEC),as well as life safety,security, pliance synchronization and access control applications. • Supports coded output operation The BPS contains the circuitry to monitor and charge internal • or external batteries. Its steel enclosure has room for up to two or restoring overcurrent protection 10 ampere-hour batteries. For access control-only applications, • Multiple signal rates the BPS can support batteries totaling up to 65 ampere-hours in • Can be cascaded or controlled independently an external enclosure.The BPS has four Class B(convertible to • Easy field configuration two Class A)NACs.These can be activated in one or two groups from the BPS's unique dual input circuits. • On-board diagnostic LEDs identify wiring or internal faults • Standard EDWARDS keyed lockable steel cabinet with re- The BPS is available in 6.5 or 10 ampere models. Each output movable door circuit has a capacity of three amperes;total current draw cannot exceed the unit's rating. • 110 and 230 Vac models available • Accommodates 18 to 12 AWG wire sizes The BPS meets current UL requirements and is listed under the following standards: • Optional tamper switch Standard rell. 16.004010.-- ____... Aseesiii —• Dual battery charging rates ,,,, UL864 9th edition(UO)0X)Fre Alarm Systems • Optional earthquake hardening:OSHPD seismic pre approval UL636(ANET,UEHX7) Holdup Alarm Units and Systems UL609(AOUC,AOTX7) Local Burglar Alarm Units and Systems for component Importance Factor 1.5 UL294(ALVY,UEHX7) Access Control Systems UL365(APAW,APAW7) Police Station Connected Burglar Alarm Units and Systems UL1076(APOU,APOU7) Proprietary Burglar Alarm System Units UL1610(AMCX) Central Station Alarm Unit ULC-s527(UOXXC) Control Units,Fire Alarm(Canada) ULC-5303(AOTX7) Local Burglar Alarm Units and Systems(Canada) C22.2 No.205 Signaling Equipment(Canada) Page 1 of 4 is A E A Ili -} E85005-0125 Plot to be used for installation purposes. Issue 1 Application Dimensions The BPS provides additional power and circuits for notification ap- pliances and other 24 Vdc loads. It is listed for indoor dry locations and can easily be installed where needed. D5 O 0 0 Top View Fault conditions are indicated on the on-board diagnostic LEDs, opening the BPS input sense circuit and the trouble relay(if D2 1 D3 11 programmed).While this provides indication to the host system, ... I the BPS can still be activated upon command.A separate AC Fail contact is available on the BPS circuit board,which can be 04—D4—*0 o . °_—.A- programmed for trouble or AC Fail.There are seven on-board diagnostic LEDs:one for each NAC fault, one for battery fault,one ani • Front View O for ground fault,and one for AC power. m • The unique dual-input activation circuits of the BPS can be acti- vated by any voltage from 6 to 45 VDC(filtered-regulated)or 11 O to 33 Vdc(full-wave rectified, unfiltered).The first input circuit can D1 D6 be configured to activate 1-4 of the four possible outputs.The a second input circuit can be configured to control circuits 3 and 4. All knockouts m When outputs are configured for auxiliary operation,these circuits for 3/4 in conduit can be configured to stay on or automatically deactivate 30 sec- o (1.9 cm) o E. onds after AC power is lost.This feature makes these circuits ideal 0 0V for door holder applications.The BPS also has a separate 200 mA 24 Vdc output that can be used to power internal activation V ......- I , J L modules. BPS NACs can be configured for a 3-3-3 temporal or continuous Di D2 D3 D4 05 D¢ output.California temporal rate outputs are also available on cer- 17.0 in 3.5 in 13.0 in 6.5 in 3.375 in 12.0 in tain models.This makes the BPS ideal for applications requiring (43.2 cm) (8.9 cm) (33.0 cm) (16.5 cm) (8.6 cm) (30.4 cm) signaling rates that are not available from the main system. In addition to the internally generated signal rates,the BPS can also be configured to follow the coded signal rate of the main Wire routing Power-limited system NACs.This allows for the seamless expansion of existing wiring area NACs. The BPS enclosure has mounting brackets for up to three Signa- "\\V u 1 ture modules to the right of the circuit board. =\\'`a`\%ri'*k,.':\\\ + ,...\\\\\\\�� 4 ,r \\\ _ Engineering Specification = [ G,. Supply,where needed, EDWARDS BPS Series Booster Power Supplies(BPS)that are interconnected to and supervised by the _ , o ! _ _ main system.The BPS shall function as a stand-alone auxiliary : 0 power supply with its own fully-supervised battery compliment. • — [3]��\V�\y 71 The BPS battery compliment shall be sized to match the require- Route AC supply ' 41041 �.• 19. i\�\«�44 ments of the main system.The BPS shall be capable of supervis- through these • - 1 I:II .v �' w ing and charging batteries having the capacity of 24 ampere-hours knockouts only 4 J for Mass Notification/Emergency Communication(MNEC),life (Nonpower-limited .0.1if 11 I n safety and security applications,and the capacity of 65 ampere- and supervised) Battery wiring (nonpower- hours for access control applications. o limited and supervised) o «The BPS shall be capable of installation for a seismic com- Battery Battery e -- ponent Importance Factor of 1.5.»The BPS shall provide a minimum of four independent,fully supervised Class B circuits F _I that can be field configurable for notification appliance circuits or auxiliary 24 Vdc power circuits. BPS NACs shall be convertible to a minimum of two Class A NACs. Each BPS output circuit shall be Notes rated at 3 amperes at 24 Vdc. Each output circuit shall be pro- 1. Maintain 1/4-inch(6 mm)spacing between power-limited and nonpower-limited vided with automatically restoring overcurrent protection.The BPS winng or use type FPL,FPLR,or FPLP cable per NEC. [2] Power-limited and supervised when not configured as auxiliary power.Non- shall be operable from the main system NAC and/or EDWARDS supervised when configured as auxiliary power. Signature Series control modules. BPS NACs shall be configurable [3] Source must be power-limited.Source determines supervision. for continuous,3-3-3 temporal or optionally, California rate. Fault 4. When using larger batteries,make sure to position the battery terminals towards conditions on the BPS shall not impede operation of main sys- the door. tern NAC.The BPS shall be provided with ground fault detection circuitry and a separate AC fail relay. Page 2 of 4 DATA SHEET E85005-0125 Not to he u sera for installation purposes. Issue 1 Typical Wiring NAC Circuit >To next signaling Single or cascaded booster device,booster,or NAC Circuit ` / ` f >EOL resistor anywhere on a notification appliance circuit V v ExistingNAC end-of-line resistors are not required to be > > >NAC output#1 q Fire Alarm N n >NAC output#2 installed at the booster's terminals.This allows multiple Control Panel 2 >NAC output#3 ry boosters to be driven from a single NAC circuit without the F a >NAC output#4 need for special configurations. Booster Power Supply Configuring the Booster for Multiple CC1(S) modules using the AC Power Fail delay operation* BPS's sense inputs TB10 Notification appliance circuit(NAC) TB1 Notification appliance circuit(NAC) AUNAC1/+ IM E listed NAX1 + g MZ EUlisted AUX1 - CO 0i D� EOL 15 k4 AUX1 - � DMZ EOL 15 KW NAC2/ + a NAC2/ + a AUX2 - © Notification appliance circuit(NAC) AUX2 - QJ Notification appliance circuit(NAC) NAC3/ + © UL listed NAC3/ 5d �J ©� AUX3 - ©� EOL OL 15 kit AUX3 - a ©� ©� EOL 15 KW NAC4/ + ©J NAC4/ + QJ AUX4 - © AUX4 - 200 mAAUX 0 © + 200 mAAUX 0 �J Continuous IT ® - Continuous m IN7© + INI* + Sense 1 COM I©1 Sense 1 COM I EOL 47 K OUTI© - + OUTI© INI® 7 Il-lmB' INI© + Sense 2 COM I® EOL 47 kit 10 9 Sense 2 COM I EOL 47 K - OUT aCC1(S)module[1][3] OUT © + + NC �'t �F�Z Z rx NO n 0 o NO © Trouble COM © 8 7 6 5 4 3 2 1 Trouble COM © 7 in t 11 l01�,,,L„ lave '�11 NC © 10 9 10 9 I [ TB2 I"'trl♦I +- +-+- TB2 CC1(S)module CC1(S)module B 7 • Data in from Data out to 8765 0403 321 8765 421 CT1 previous device — next deviceo o•- Iq o•t��o o 'I module[4] �I �-[1] [__, [1 0 0 or Signature +-+- +-+- r controller Data in from previous Data out to *The Booster supports AC Power fail delay —►[3] device or Signature r of three hours via its trouble contact when controller› —3 next device dip switch SW2-6 is on.All other troubles are reported to supervising module or panel without delay via Sense inputs. Security and access BPS TB1 24V 12V NAC1/ +TB1 Security Security EOL ���� 24DC12 ��� monitoring AUX1 -ISI device device device NAC2/+I ] AUX2 -[t I NAC3/+[ 7 AUX3 -I I NAC4/+i i AUX4 -I 7 Control panel BPS[1] Card reader Card reader Card reader controller controller — controller + - + - + - - A- 1- To next device [1] Disable the BPS's ground fault jumper(JP3) or end Page 3 of 4 DATA S II E E t E85005-0125 Not to be used for instailaBon €_,;,, Issue 1 Specifications E DWAR DS Model 6.5 amp Booster vaamp Booster. AC Line Voltage 120VAC or 220-240VAC 50/60Hz 120VAC or 220-240VAC 50/60Hz 390 watts 580 watts r it r .Ai err,,,, qu(.if;1 N M/.r..:c,LMEN'I" Notification Appliance 3.0A max.per circuit©24Vdc 3.0A max.per circuit 0 24Vdc Circuit Ratings nominal 6.5A max total all NACs nominal 10A max total all NACs Contact us... Trouble Relay 2 Amps 0 30Vdc Email: edwards.fire@fs.utc.com Auxiliary Outputs Four configurable outputs replace NACs 1,2,3 or 4. as auxiliary Web: Edwards-fire.com outputs and 200 mA dedicated auxiliary.(See note 2.) Input Current 3mA 0 12Vdc,6mA 0 24Vdc EDWARDS is a UTC brand. (from an existing NAC) 1016 Corporate Park Drive Booster Internal 70mA+35 mA for each circuit set to AUX Mebane,NC 27302 Supervisory Current ©2016 United Technologies Corporation. Booster Internal Alarm 270mA All rights reserved. Current Signature Mounting Accomodates three two-gang modules. Space Maximum Battery Size 10 Amp Hours(2 of 12V10A)in cabinet up to 24 Amp hours with ex- ternal battery cabinet for fire and security applications;up to 65 Amp hours for access control applications in external battery box. Terminal Wire Gauge 18-12 AWG Relative Humidity 0 to 93%non condensing 0 32°C Temperature Rating 32°to 120°F(0°to 49°C) NAC Wiring Styles Class A or Class B Output Signal Rates Continuous,California rate,3-3-3 temporal, or follow installed panel's NAC.(See note 1.) Ground Fault Detection Enable or Disable via jumper Agency Listings UL,ULC,CSFM 1. Model BPS*CAA provides selection for California rate,in place of temporal. 2. Maximum of 8 Amps can be used for auxiliary output. Ordering Information Catalog Description Shipping Number Wt.lb(kg) BPS6A 6.5 Amp Booster Power Supply 13(5.9) BPS6AC 6.5 Amp Booster Power Supply(ULC) 13(5.9) BPS6A/230 6.5 Amp Booster Power Supply(220V) 13(5.9) BPS6CAA 6.5 Amp Booster Power Supply with California rate 13(5.9) BPS1OA 10 Amp Booster Power Supply 13(5.9) BPS1OAC 10 Amp Booster Power Supply(ULC) 13(5.9) BPS10A/230 10 Amp Booster Power Supply(220V)- -- 13(5.9) BPS10CAA 10 Amp Booster Power Supply with California rate 13 5.9) 1. Requires installation of sepa- rate battery cabinet. Related Equipment 2. BPS supports batteries greater 12V6A5 7.2 Amp Hour Battery,two required 3.4(1.6) - than 24 Amp hours for access control applications only. 3. For earthquake anchorage, 12V10A 10 Amp Hour Battery,two required 3 TAMP Tamper switch including detailed mounting BC 1 EQ Seismic Kit for BC 1. Order BC-1 separately.See note 3. weights and center of gravity detail,refer to Seismic Applica- tion Guide 3101676. Approval BPSEQ Seismic kit for BPS6A or BPS10 Booster Power Supplies.See note 3 of panel anchorage to site WBC 1 Battery Cabinet(up to 2-40 Amp Hour Batteries) 58(26.4) structure may require local BC 2 Battery Cabinet(up to 2 17 Amp Hour Batteries) 19(8.6) AHJ,structural or civil engineer 12V17A 18 Amp Hour Battery,two required(see note 1) 13(5.9) review. 12V24A 24 Amp Hour Battery,two required(see note 1) 20(9.07) 12V40A 40 Amp Hour Battery,two required(see notes 1,2) 32(14.5) 12V50A 50 Amp Hour Battery,two required(see notes 1,2) 40(18.14) 12V65A 65 AmpHour Battery,two required(see notes 1,2) 49 22.2 Q ( ) 4 Page 4 of 4 C, SHEET E85005-0125 Not to be € for installation purposes. Issue 1 , .;a 0. Small Building Fire alarm Solutions bWARDB United Technologies Intelligent Fire ,,,.. .„ .,: oar 1 .:,...._ Alarm Systems .v.. .„ :u„. ... ,_ „, 1064 IO1000 FDEnNY ..w ons C0A6227 i IWAROa T<, iiiimi 7165-1657: ... ., i 0244 -, `cawAao„s € S3000 Overview Features EDWARDS brand intelligent life safety systems offer the power • Auto-programming speeds installation time of high-end intelligent processing in configurations that deliver • Supports Signature Series intelligent modules and detectors uncomplicated solutions for small to mid-sized applications.With intelligent detection,electronic addressing,automatic device • Combines the Signature intelligent releasing module with mapping,optional Ethernet°connectivity,and a full line of easily- Signature multisensor detectors for reliable fire suppression configured option cards and modules,these flexible systems offer • Form C contacts for alarm and trouble, Form A for supervisory versatility that benefits building owners and contractors alike. • Electronic addressing with automatic device mapping The 1064 provides one Class A or Class B intelligent device loop • Optional Ethernet port for diagnostics, programming and a that supports up to 64 device addresses,and two Class B Notifi- variety of system reports cation Appliance Circuits(NACs).Optional Class A device wiring is available with the use of a module. • Two programmable switches with LEDs and custom labeling The 101000 provides one Class A or Class B intelligent device • Supports Genesis horn silence over two wires,and UL loop that supports up to 250 device addresses. Loop controller 1971 compliant strobe synchronization modules may be added in combination to expand total system • Class B or Class A wiring capacity in 250-point increments to up to 1,000 device addresses. • Ground fault detection by module The iO1000 panel includes four NACs that may be wired for either Class A or Class B operation. • Supports up to eight serial annunciators,(LCD, LED-only,and graphic interface) The RZ116-2 module adds even more capacity to iO installations • Can use existing wiring for most retrofit applications by adding up to 16 conventional device circuits and two additional notification appliance circuits.This makes them an ideal retrofit • Upload/download remotely or locally solution that can accommodate new intelligent detectors,as well • Two-level maintenance alert reporting as existing conventional devices. • Pre-alarm and alarm verification by point iO Series supports a wide range of high-end features, including: • Adjustable detector sensitivity • Signature Series intelligent modules,detectors,and bases • 4 x 20 character backlit LCD display • R Series remote annunciators • Optional earthquake hardening:seismic Importance Factor 1.5 • SIGA-REL Releasing Modules • Standalone operation • Fully integrated CO detection using Signature Series detec • Transmission test frequency by hour tors with or without audible signaling Page 1 of 8 E85001-0135 Issue 1.1 Application EDWARDS iO Series life safety systems are powerful intelligent solu- Flexibility built right in tions for small to mid-sized buildings.Advanced intelligent technol- Two fully-programmable front panel switch/LED combinations pro- ogy delivers the benefits of flexible system installation,while clean vide an added measure of flexibility.Their slide-in labels take the and easy-to-operate user interfaces make panel operation and mystery out of custom applications,and present a clean finished system maintenance quick and intuitive. appearance. The smart choice Perfect for retrofits Signature Series electronic addressing eliminates the tedium of EDWARDS i0 Series control panels are particularly well-suited to setting dipswitches,and automatic device mapping ensures that retrofit applications.All connections are made over standard wiring each device resides on the system at its correct location. Mean- -no shielded cable required.This means that in most situations while, innovative programming allows the designer to customize existing wiring can be used to upgrade a legacy control panel to the system to precisely suit the needs of the building owner. iO technology without the expense or disruption of rewiring the en- tire building.i0 control panels also support the ingenious RZI16-2 Reliability you can count on Zone Module,which adds up to 16 conventional circuits and two The inherent fault-tolerant characteristics of Analog/Addressable NACs.This combination easily accommodates new intelligent Technology boosts the reliability of EDWARDS fire alarm systems. detection alongside existing conventional circuits,making it an When combined with i0 Series smoke and heat detectors,these superior solution in the retrofit market. systems deliver a level of dependability not previously available for small to mid-sized applications.All EDWARDS systems are built to Signals with a difference exacting reliability benchmarks and meet international standards iO system NACs are configurable to fully support the advanced for quality, in addition to agency listings for dependability. signaling technology of EDWARDS Genesis and Enhanced Integ- rity notification appliances.These devices offer precision synchro- Clear-cut remote annunciation nization of strobes to UL 1971 standards. For Genesis devices, Remote annunciation is a strong suit of the i0 Series fire alarm enabling this feature allows horns to be silenced while strobes on systems. Up to eight annunciators can be installed on a single the same two-wire circuit continue to flash until the panel is reset. system.Compatible annunciators include a range of LED and LCD models that provide zone or point annunciation,as well as com- A complete line of accessories mon control capabilities. iO control panels also supports graphic iO Series life safety systems are supported by a complete line of annunciation with optional RA Graphic Annunciator interface mod- analog/addressable detectors,modules and related equipment. ules. Each interface provides common control and 32 LEDs. Consult the Ordering Information section for details. Programming and remote diagnostics Dimensions EDWARDS iO Series life safety systems are simple to set up,yet 0) ��� 97 (21 t31 e) offer advanced programming features that put these small building __. or-.1 panels into a class of their own.The auto programming feature 0 0 0 ` 0 '0 T -__. quickly gets the panel operational using factory default settings. I" ,' I O j .,d 0 Basic zone and point settings can be programmed through the 0 0 front panel interface,so the system is up and running in no time. I I O D'' 0 0 For more advanced system configuration and correlation groups o, ( 'oas programming, i0 Series systems interface to a PC running com- 'e _o ' O O patible iO-CU software.This option offers full system configuration in the familiar Windows®operating environment.Connection is ° 1 , made to a laptop through the panel's optional RS-232 communi- i cations port,which can also be used to connect a system printer. - -06n JAmong the many innovative features of iO Series control panels is the optional network card.This module provides a standard (1)Surface Mounting Holes (3)Backbox with Door Attached 10/100 Base T Ethernet®network connection that permits access (2)Semi-flush mounting Holes (4)Backbox with door and trim kit attached. to the control panel from any remote location with the correct communications protocols.The connection can be used to Panel dimensions„in(cm) download to the panel from the iO-CU,or upload and view system Model D1* D2 03 D4 D5' De 07 D8 D9 reports using the i0-CU. 101000 28.0 3.85 9.0 22.0 15.75 TO.25 4.4 28.2 2.7 (71.1) (9.8) (22.8) (55.8) (40.0) (26.0) (11.1) (71.6) (6.8) Available system reports include: 1064 21.5 3.85 7.5 15.5 14.25 10.25 4.5 21.7 2.7 (54.6) (9.8) (19.0) (39.4) (36.2) (26.0) (11.4) (55.1) (6.8) • Correlation groups • Device details 'Add 1-1/2 in.(3.81 cm)to D1 and D5 dimensions for trim kit.The trim kit • Device maintenance • History provides 0.75 inches(1.9 cm)of trim to the top,bottom,and sides of the backbox. • Internal status • System configuration • System status • Walk test • Dialer • CO runtime Page 2 of 8 E85001-0135 pc Issue 1.1 System Layout 101000 Any combination of two single-or dual Signature loop modules .. I j I: Standard Loop:250 points(one expansion slot) I0-SDC2 Expander,Loop 1 of 2:250 points Up■■■■••to 125 sensors and 125 modules perr loop (one expansion slot) t ‘,„Iiii rM " , Mt 10-SDC1 Expander 250 points(one expansion slot) 10-SDC2 Expander, 2 of 2:250 points Up to 20,000 feet of wiring per loop , s , , FIRE FIRE FIRE FIRE '•yT �lip . ' „�„ FIRE' FIRE FIRE FIRE FIRE 7 � Four Class B or two optional Class A NACs �. .7~ ' - Four Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster �Yr OiC �- „ ..oLR Ethernet(SA-ETH) i - DACT/Dialer(SA-DACT) - - Up to eight remote annunciators RS-232(SA-232) ) Sixteen Conventional IDCs, Relays:Two Form C,one Form A , two additional NACs with RZI16-2 module Each iO1000 panel has room for up to two Signature loop control- ler modules in any combination of single or dual 250-device loops. iO1000 loops support 125 detectors and 125 modules. Panel Layout X0880 s 3 °°41�r 'air 1064 2 x.)4iLa.: p s ' '«m°:*g "11 B ozJr ® 9 a Loop supports up to 64 intelligent devices of any type. : : _� ISI [ 10 Up to 20,000 feet of wiring. •-- '7.... ..7.x. 011 d,.,: 1 12 FIRE FIRE FIRE FIRE` T"-' L7, r to d=1. 13 Two Class B or two optional Class A NACs Optional 10 A or 6.5 A Booster Power Supply .1-i- ° i -- a , 1 Transformer Up to eight remote annuncuato i ` 2 Main AC wiring block&fuse holder 3 RS-232 card connector(J3) Ethernet(SA-ETH) - x. 4 Dialer card connection(J8) DACT/Dialer(SA-DACT) ] t 5 Ethernet card connector(J1) 6 Main circuit board RS-232(SA-232) — ° °°°°w. � 7 Panel backbox enclosure Relays:Two Form C,one Form A 8 Operator interface 9 SLC card connector(J7) 10 Class A card connector(J2) Each i064 panel ships with one Signature loop controller that sup- 11 Tie wrap mounts 13 LED expander connector(J6) ports 64 devices of any type.This panel's device capacity cannot 13 Standby batteries be expanded. Page 3 of 8 E85001-0135 Issue 1.1 Wiring & Configuration Signature device loop Auxiliary&smoke power outputs(TB3) The system provides one Signature device loop circuit with a total The control panel provides two auxiliary power TB3 capacity of 125 detectors and 125 module addresses.The loop outputs that can be used for powering ancillary 0"1 circuit is supervised for opens, shorts,and grounds. equipment such as remote annunciators and two (1) ® NO wire smoke detectors. Aux 2 can be software NC Circuit i01000 i064 selected to operate continuously.The circuit is 0 specifications — supervised for shorts and grounds. Device loops One Class B or A One Class B or A loop, (2) 0--J....NO loop,supporting 125 supporting 64 devices of Circuit specifications 0--� detectors and 125 any kind. Circuit voltage 21.9 to 28.3 V modules.Expandable to range 0 NC four loops. Resettable circuit 24 VDC nominal at 500 mA (3) e Communication Maximum 20 V peak-to-peak (Aux power 2) NO line voltage (2) Circuit current 0.5 A max Continuous circuit 24 VDC nominal at 500 mA. (Aux power 1) Use this circuit for powering 0 Circuit 660 total,0.5 pF,max two-wire smoke detectors. impedance (4) 0 Isolators 64 maximum Note:My current above 0.5 amp connected to both Aux 1 and 2 will reduce the total available NAC power by that 0 Signal Supported on a system-wide basis(all device loops) amount. Synchronization when using a SIGA-CC1 S or SIGA-MCC1 S module (1)Trouble and Genesis or Enhanced Integrity notification ap- pliances. Alarm,trouble,and supervisory relay(TB3) (2)Supervisory The trouble relay is normally-open, held closed, (3)Alarm Clone wiring Class Awiring and opens on any trouble event or when the panel is de-energized.The supervisory relay is (4)Smoke/Aux SLC A ,® Data Lee SLC A ;0 normally-open,and closes on any supervisory T. event.The alarm relay changes over on any SLC B • 11�� SLC B (si ���® - J— alarm event. Loop Loop Loop Loop Loop card device device L"I"Ord Dole Line tlaWce tleNca Relay specifications Alarm i Trouble Supervisory Type Form C Form A Notification appliance circuits(TB2) Voltage 24 VDC at 1 A resistive 24 VDC at 1 A resistive 101000 control panels come equipped with four notification ap- Relay circuits can only be connected to power-limited sources. pliance circuits.064 control panels come with two NACs. Each circuit can be individually configured for continuous,temporal, synchronized,and coded output. Annunciator loop(TB4) Specifications 101000 1064 The control panel provides a connection for up to eight serially Circuit Type 4 Class B or 2 Class A 2 Class B or 2 Class A driven and supervised remote annunciators. with SA-CLA module Voltage 24 VFWR Circuit specifications Current 6.0 A total,2.5 A max. 3.75 A total,2.5 A max. Device loops Class B(Style Y)or Class A(Style Z) per circuit at 120/230 per circuit at 120/230 Circuit voltage 2.55 V VAC 60 Hz. VAC 60 Hz. Circuit current 30 mA max 5.0 A total,2.5 A max. 3.0 A total,2.5 A max. Circuit Up to 8 annunciators or 4000 feet per circuit at 230 VAC per circuit at 230 VAC impedance 50 Hz. 50 Hz. Impedance 26 O total,0.3b pF Max Class B Class A EOLR 15K0,1/2W Channel 1 Channel 2 Channel 1 Channel 2 Synchronization Supported system-wide + — + — + — + — iis) QQTB4 ® iso ® T84 Class a wiring Class A wiring Annunciator Annunciator NAC1- '61131111311DNAC7- ®CH1(+)IN ®CH1(+)IN NAC1+ 61131111311DNi + <1_ -+ a ®CH1(-)IN CH1(-)IN NAC2- EOLR NAC2- ,} NAc2+ ®��H NA , _Q +_Q CH2(+)IN ®CH2(+)IN Tse Tee _ NAS- ®CH2(-)IN t CH2(-)IN °, 4111:■®•1M 0 14.11 EOLR TBC TR Marking indicates output signal polarity when the circuit is active.Polarity reverses when the circuit is not active.Wire notification appliances accordingly.Notification appliance polarity shown in active state. Page 4 of s E85001-0135 t'1,lt TO hP iiseei for Issue 1.1 Option Cards EDWARDS iO Series panels are supported by a complete line RZI16-2 Remote Zone Interface Module of modules and related equipment that enhance performance — -w and extend system capabilities.Option cards plug directly into ° C71 471 isr the control panel main circuit board or are connected to it with affis-a.i ribbon cable.After installation,terminals remain accessible.The -va 4 cabinet provides ample room for wire routing, keeping wiring neat -CI _ENS - at all times. ie— I Single and Dual Loop Controller Cards The RZI16-2 Addressable Remote Zone Interface Module is an The iO-SDC1 is a single loop controller card that can be used with addressable device that provides connections for sixteen Class B the i064 as a replacement for the standard 64-point loop,or with Initiating Device Circuits and two Class B Supervised Output the iO1000 as a 250-point expansion module. Circuits.The inputs and outputs can be configured individually for The iO-SDC2 is a 500-point dual loop controller card for the several device types. iO1000 that provides two SLC circuits,each with 125 detector It requires 18 consecutive addresses on the Signaling Line Circuit addresses and 125 module addresses. (SLC).Addresses are assigned electronically.There are no address switches to set. Specifications i0-SDC1 iO-SDC2 Device Addresses ' i01000:one loop,250 i01000:two loops, The RZI16-2 incorporates two 8-segment DIP switches that are device addresses 500 device addresses used to select the Alarm or Supervisory default device type for i064:64 addresses each of the 16 IDC circuits.The module also includes one 4-seg- Wiring Class B or Class A ment DIP switch used to select the default Relay or NAC output Operating Voltage 24 VDC device type. Device types other than the default are accomplished Operating Current Standby:55 mA Standby:45 mA through programming. (fully loaded loop) Alarm:80 mA Alarm:70 mA Note:These ratings do not include the use of two-wire smoke modules. 132116-2 Specifications Communication Line Max.20.6 V peak-to-peak Voltage Voltage 24V/Aux nominal: 24 VDC Terminal Rating 12 to 18 AWG(0.75 to 2.5 mm2) Supervisory current: 250 mA at 24 VDC nominal Alarm Current 1000 mA Circuit Current 0.5 A max. 24V/Aux minimum: 18.4 VDC Max total loop __ 66 0 24V/Aux maximum: 26.4 VDC resistance _ _ NAC1,NAC2 nominal: 24 VDC Max total loop 0.5 NF Current capacitance _ Standby current Isolators 64 isolators maximum per loop(total both for 4.7 k EOL(U.S.) 4.8 mA/circuit isolator bases and modules)_ Standby current for Ground Fault 0 to 5 kO 3.9 k EOL(Canada) 5.7 mA/circuit Impedance Alarm current Operating 32 to 120°F(0 to 49°C) at nominal voltage 31.1 mA/circuit Environment 0 to 93%noncondensing at 90°F(32°C) Relay outputs Quantity 2 Type Rating(pilot duty) Programmable 24 VDC at 2.5 A Input circuit wiring 25 0 per wire SA-ETH Ethernet Interface Card resistance SA-ETH wiring The SA-ETH card provides a Initiating device circuits To network r.....9�„n , standard 10/100 Base T Ether- Quantity 16 Network cable . EOL resistor 4.7kO(U.S.);3.9 kO Canada �I I. net network connection for IWconnecting to an intranet,a local Zone voltage 22.78 V for 4.7 kO(U.S.) 22.08 V for 3.9 kG(Canada) 1 network,or the Internet.The Alarm current 31.1 mA/channel at nominal voltage l card can be used to download ® Alarm impedance range <680 0 g0 configuration programming from Trouble impedance .i0-CU panel. __ — _._ ® � p Supervised output circuits l`T�7 The Ethernet card is installed on EOL resistor 15 kO ® - the plastic assembly and con- Quantity 2 ®_ Short circuit detection <2.6 kO nects to the main circuit board Open circuit detection >61.9 kG Ethernet card via a ribbon cable. Contact ratings 24 VDC at 2.5 A(5 A for two NACs) SA-ETH specifications Compatible cabinets MFC(A),iO1000,APS - Ethernet 10/100 Base T Operating environment Temperature 32 to 120°F(0 to 49°C) Humidity 0 to 93%RH,noncondensing at 90°F (32°C) Page 5 of 8 E85001-0135 Issue 1.1 SA-DACT Dialer SA-232 RS-232 interface The SA-DACT provides communications between the control The SA-232 card provides an RS-232 in- sA-232 wiring panel and the central station over a telephone line system. It terface with iO panels. It can be used for GND(black wire) ----^TXD(white wire) transmits system status changes(events)to a compatible digital connecting a printer to the control panel —RXD(red wire) alarm communicator receiver over the public switched telephone to print system events.The card also network.The dialer is capable of single, dual,or split reporting can be used for connecting a computer erOSSSei r"-- of events to two different account and telephone numbers.The to download a configuration program ❑ 'Li 0 .B „1 modem feature of the SA-DACT can also be used for uploading from the 0-CU to the control panel. and downloading panel configuration, history,and current status The RS 232 card is installed on the pias to a PC running the iO-CU. tic assembly and connects to the main circuit board via a ribbon SA-DACT Phone line 2 cable. wiring Phone line I To wall phone jack SA-232 specifications Phone cables .. , Operating voltage Standard EIA-232 (supplied) 11 RJ31 jacks -- 1111 n_� Terminal rating 12 tel AWG(0.75 to 2.5 sq mm) 'a' The dialer phone lines connect to Operating environment connectors on theedialer's main Temperature 32 to 120°F(0 to 49°C) i.. a circuit board.Phone line 1 connects Humidity 0 to 93%RH,noncondensing at 90°F(32°C) >•ale 1°01 to connector J4 and phone line 2 �❑ o connects to connector J1. .o SA-CLA Class A Module(i084 only) ❑❑ °�° _o The SA-CLA card provides Class A capability for NAC wiring. nu❑❑JLJ:1 o °� Its terminal block provides the wiring connection for NAC return L1 i5 wiring.The card is required for annunciator Class A wiring even s& though this wiring does not return to the SA-CLA card.The SA- The SA-DACT queues mes- CLA is compatible with 1064 control panels only. iO1000 panels sages and transmits them based on priority(alarm,supervisory, are Class A Ready.The SA-CLA is installed directly to the control trouble,and monitor).Activations are transmitted before restora- panel circuit board using its plastic standoffs and plug connection. tions. SA-CLA specifications The SA-DACT is installed on the plastic assembly and connects to Operating voltage 24 VFWR the main circuit board via a ribbon cable. Operating current 3.75 A FWR total at 120/230 VAC 60 Hz SA-DACT specifications 3.0 A FWR total at 230 VAC 50 Hz 2.5 A max per circuit Phone line type One or two loop-start lines on a public, Circuit impedance 26 ohms,0.35uF switched network Terminal rating 12 to18 AWG(0.75 to 2.5 sq mm) Phone line connector RJ-31/38X(C31/38X) Operating environment Communication formats Contact ID(SIA DC-05) Temperature 32 to 120°F(0 to 49°C) Operating environment Humidity 0 to 93%RH,noncondensing at 90°F Temperature 32 to 120°F(0 to 49°C) (32°C) Humidity 0 to 93%RH,noncondensing at 90°F - (32°C) Compatible DACRs D16L-10 LED Display Expander(iO1000 only) Receiver Models Formats The D16L-i0 LED Display Expanders provide LED annunciation for Ademco 685 Contact ID up to 16 zones. It provides two LEDs for each zone.Two D16L-i0 FBII CP220 Contact ID LED display expanders can be installed in each iO1000 panel. Osborne-Hoffman OH 2000 Contact ID Pasch D6600 _ _ Contact ID (3) (4) Silent Knight 9800 Contact ID (2(1) 4�11Fr'f1 (Z) Zone 17 (1)LED 1 Sur-Gard SG-MLR1,MLR2 Contact ID (2)LED 2 ,:1 1111111111 ':1 :1 (3)LED Expander 1 {1 ion.= (4)LED Expander 2 14011.10 .11111.11. (5)Alarm/non-alarm 1- .111111111•111 and trouble zone LEDs MINN 11111 MO :1111111111 1111111/1 AMN MINN ;:1x11111 ismil 17 ilt ::immil 5111 ,:Min _A Zone 32 Page sof8 L_/,i?, .rr,- l E85001-0135 N,, - 're used for mstallarIssue 1.1 Specifications 1064 101000 Device loops 1 loop Class B or Class A(Styles 4,6,7)supporting up to 1 loop,expandable to 4,Class A or B(Styles 4,6,7), 64 device addresses(any combination of detectors and each loop supporting up to 250 device addresses(125 modules) detectors and 125 modules max.).Addresses 1 to 125 are Maximum T-taps:63 for detectors and addresses 126 to 250 are for modules (each device can be on its own branch) Maximum T-taps/loop: 124 Notification appliance 2 Class B(Style Y),Class A(Style Z)optional 4 Class B(Style Y)or 2 Class A(Style Z) circuits 3.75 A FWR total at 120/230 VAC 60 Hz 6.0 A FWR total at 120/230 VAC 60 Hz 3.0 A FWR total at 230 VAC 50 Hz 5.0 A FWR total at 230 VAC 50 Hz 2.5 A FWR each max.per circuit 2.5 A FWR each max.per circuit Primary power 120 VAC,60 Hz, 1.3 A max. 120 VAC,60 Hz,2.0 A max. 230 VAC,50-60 Hz,0.62 A max. 230 VAC,50-60 Hz,0.97 A max. Base panel current standby 155 mA 172 mA Base panel current alarm 204 mA 267 mA Input zones 16 max. 32 max. Remote annunciator 8 drops max.,RS-485 Class B,Class A is optional 8 drops max.,RS-485 Class A or B Data line length:4,000 ft.(1,219 m) Data line length:4,000 ft.(1,219 m) Operating voltage 24 VDC panel Auxiliary power output Aux power 1:500 mA,24 VDC circuit Aux power 2:500 mA,24 VDC(1 A possible if you reduce total available NAC power by 500 mA) Output:28.3 to 21.9 VDC,special application Note:For a list of compatible devices,see the i064 and iO1000 Series Compatibility List(P/N 3102353-EN) Loop circuit Maximum loop resistance:66 0 Maximum loop capacitance:0.5 pF Communication line voltage:Maximum 20.6 V peak-to-peak Operating current(fully loaded loop)Stand by:55 mA/45 mA Alarm:125 mA/115 mA(not including two-wire smoke modules) Circuit current:0.5 A max.Style 4,6,and 7 wiring Max.resistance between isolators:Limited only by overall wire run lengths 64 isolators maximum per loop(total both isolator bases and modules) Batteries Type:Sealed lead acid Voltage:24 VDC Charging current:2.47 A max.Amp hour capacity:26 Ah Standby operation:24 hour or 60 hour Placement:Up to two 10 Ah batteries will fit in the iO64 control panel cabinet and two 18 Ah batteries will fit in the iO1000 control panel cabinet.If larger batteries are required,use an EDWARDS battery cabinet. SA-DACT dialer Phone line type:One or two loop-start lines on a public,switched network Phone line connector:RJ-31/38X(C31/38X) Communication formats:Contact ID(SIA DC-05) Operating current Standby/Alarm:41 mA Max.:100 mA FCC registration number:GESALO1 BSADACT Industry Canada Registration number:3944A-SADACT Ringer equivalence number:0.1B Ground fault impedance 0 to 5 kO Alarm contact Form C N.O.24 VDC at 1 A(resistive load) Trouble contact Form C 24 VDC at 1 A(resistive load) Supervisory contact Form A N.O.24 VDC at 1 A(resistive load) Environmental Temperature:0 to 49°C(32 to 120°F)Relative humidity:0 to 93%noncondensing Terminal rating All terminals rated for 12 to 18 AWG(0.75 to 2.5 mm2) Page 7 of 8 u::r f; :: ,4 E85001-0135 ^tot to be utioa for!..stallat Issue 1.1 Ordering Information cdDVVA►R. OS Part Description iO1000Fire Alarm Systems 101000G Four loop system with one 250-point loop installed. 110v,gray door. �r m i rA[.,41 101000G-2 Four loop system with one 250-point loop installed.230v,gray door. 101000G-2-PG Four loop system with one 250-point loop installed.230v,gray door,Portuguese. Contact us... 101000G-2-SP Four loop system with one 250-point loop installed.230v,gray door,Spanish. Email: edwards.fire©fs.utc.com 101000G-CA Four loop system,one 250-point loop installed.110v,gray door,LED strips,Canada. Web: Edwards-fire.com IO1000GD Four loop system,one 250-point loop installed.110v,gray door,with dialer. I01000G-F Four loop system,one 250-point loop. 110v,gray door,LED strips,French Canada. EDWARDS is a UTC brand. 101000G-PG Four loop system with one 250-point loop installed.110v,gray door,Portuguese. 1016 Corporate Park Drive 101000G-SP Four loop system with one 250-point loop installed. 110v,gray door,Spanish. Mebane,NC 27302 101000R Four loop system with one 250-point loop installed. 110v,red door. 101000R-2 Four loop system with one 250-point loop installed.230v,red door. ©2016 United Technologies Corporation. 101000RD Four loop system,one 250-point loop installed. 110v,red door,with dialer. All rights reserved. SA-TRIM2 iO1000 Flush mount trim,black. i064 Fire Alarm Systems 1064G One loop system with one 64-point loop installed. 110v,gray door. 1064G-2 One loop system with one 64-point loop installed.230v,gray door. 1064G-2-PG One loop system with one 64-point loop installed.230v,gray door,Portuguese. 1064G-2-SP One loop system with one 64-point loop installed.230v,gray door,Spanish. 1064GD One loop system,one 64-point loop installed. 110v,gray door,with dialer. IO64GL One loop system,one 64-point loop installed. 110v,gray door,English Canada. 10640L-F One loop system,one 64-point loop installed. 110v,gray door, French Canada. IO64G-PG One loop system with one 64-point loop installed.110v,gray door,Portuguese. 1064G-SP One loop system with one 64-point loop installed.110v,gray door,Spanish. 1064R One loop system with one 64-point loop installed.110v,red door. I064R-2 One loop system with one 64-point loop installed.230v,red door. 1064RD One loop system,one 64-point loop installed.110v,red door,with dialer. SA-TRIM1 i064 Flush mount trim,black Option Cards iO-SDC1 Expansion module,one 250-device loop. iO-SDC2 Expansion module,two 250-device loops,500 devices total.For 01000 only. RZI16-2 Remote Zone Interface Module.16 Class B IDCs,2 Class B Output.Includes bracket. SA-DACT Dual Line Dialer/Modem,supports Contact ID,mounts in cabinet on base plate. SA-232 RS-232 Serial Port for connection to printers&computers,mounts in cabinet. SA-ETH Ethernet Port,Slave,mounts in cabinet on base plate. SA-CLA Class A adapter module.Provides Class A capacity on NACs.Mounts in cabinet on main board.iO64 systems only. D16L-iO-2 LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to right of LCD display for zones 17-32.For iO1000 only. D16L-i0-1 LED Annunciator module, 16 X 2-LED zones(4 programmable for sup). Mounts in cabinet to left of LCD display for zones 1-16.For iO1000 only. D8RY-iO-2 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only, 8 supervisory only,4 alarm or supervisory).Mounts in cabinet.For 101000 only. D8RY-iO-1 Canada only:LED Annunciator module,two LEDs per zone, 16 zones(4 alarm only, 8.supervisory only,4 alarm or supervisory).Mounts in cabinet.For iO1000 only. Accessories CTM City Tie Module,2-gang.Connection to 6AeffifIPRIEMy fire alarm box. MFC-A Multifunction Fire Cabinet,8"x 14"x 3.5"-red. SIGA-REL Releasing Module PT-1S System Printer BC-1 Battery Cabinet. 14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1R Battery Cabinet-Red.14.0"x 18.25"x 7.25".Holds two 12V24A batteries. BC-1 EQ Seismic hardening Kit for iO series panels.Includes battery hardening for BC-1 enclosure and components to harden panel internal components. Programming Tools 0-CU 10 Serie_s configuration and diagnostics utility. 260097 RS232 cable,4 conductor,DB9 PC interface Page 8 of 8 E85001-0135 to 110 ,1SPri tnr,nStalia*+- Issue 1.1 Annunciation EST Life Safety & Communications R-Series Remote „ \,„\\\\ 1/4\ Annunciators m RLCD, RLCD-C, RLED, RLED-C, \‘' "\I �� RLED24, GCI A \ (0) FDNY I..I LC ® COA 6020 7120-1657: COA 6087 0254 S3424 Overview Features Edwards R-Series Annunciators are high-performance remote • LCD models feature large 4 x 20 character backlit LCD display annunciators that provide status indication and common controls • LED models provide 16 pairs of LEDs for zone annunciation for compatible fire alarm control panels,including 0-Series small analog fire alarm systems.This family of annunciators offers LCD • Available expander extends capability with 24 pairs of LEDs or LED annunciation. Models are available with and without com- • Up to two expanders may be wired to each annunciator mon controls. • Status LEDs and internal buzzer standard on all models There are three R-Series annunciator models,plus an LED-based expander. Up to two expanders can be connected to any annun- • Common controls available for LED and LCD display models ciator.The expander includes 24 pairs of LEDs that extend the • Available keyswitch for disabling common controls capabilities of any of the annunciators. • Standard 4-inch square electrical box mounting All annunciator models include status LEDs and an internal buzzer. • Class B or Class A RS485 wiring standard Two models have an LCD text display,and one has 16 pairs of LEDs for zone annunciation. LCD models feature a large back-lit, • One-,two-,and three-position enclosures available four by twenty character per line, super-twist liquid crystal display. • Graphic Annunciator interface, includes common control, indi- R-Series annunciators and expanders are mounted on a standard cators and 32 LEDS 4-inch square electrical box, using the included mounting ring. • No programing required,set the address and unit recieves all They can also be surface mounted in locking steel enclosures. information from panel Three different enclosures are available. A keyswitch and graphic annunciator interface is available for R-Series annunciator applications.The keyswitch enables or dis- ables common controls.The graphic annunicator interface cards supports 32 LEDs and 16 switches on the graphic panel display. Page 1 of 4 85005-0128 to bo ,Ott ft"!"," ,+' Issue 2 Application Annunciator Wiring R-Series annunciators communicate with the FACP on the RS-485 Annunciator,Class A data riser.This can be configured for Class A or Class B commu- nication.Annunciators do not provide ground fault isolation. FACP A^^°^°/afar Annunciate RS-485 —0 CH1(+)IN —0 CH1(+)IN These annunciators are stand-alone units that can be powered by CH1. 0--I0 CH1(-)IN 0 CH1 H IN the FACP or by an approved power supply. CH1- 0 I y CH1(+)OUT 0 CH1(+)OUT CH2+ 0 0 CH1(-)OUT 0 CH1(-)OUT CH2- 0 CH2(-)IN 0 CH2(+)IN 0 C112(-)IN 0 CH2(-)IN • 1ig�,..• gf g ) ••.• LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT o w^..74 p SUPPLY J loa r t Sq I° iiri4zrw... �CN2000T 0CH2(-I OUT i �p ..w� S IgL--.i era 24VDC+0. —024V(+)IN 024V(+)IN P ��® ®„,,,, q tlla) 24VDC-0- -024V(-)IN 024V(-)IN 'C;:J..o^+4••+ g C 7 ox.... y24µ)Our °24V(+)OUT ®a• 8 1 q I • csf r++r>tj o o 7 24V(-)OUT 0 24V(-)OUT --_ \ GROUND GROUND RLCD-C RLED-C / Annunciator,Class B I IlIi-� ' il I gq ,gq -� ome FACP Annunciator Annunciator II RS-485 —0 CH1(+)IN —0 CH1(+)IN CD ED 0 S S S CH1+ 0 CH1(-)IN 0 CH1(-)IN I o111111111111111o IIIIIIIIIIIINI_o� CH1- 0 ?CHI(0)OUT 0 CH1(+) UT O MiP°" ///� �: paig—p °— y CH1(-)OUT 0 CM(-)OUT �\ Yl P `X \ I 0 CH2(+)IN 0 CH2µ)IN �. Y� 0CH2(-)IN °CH2(-)IN RLCD RLED24 LISTED 24 VDC 0 CH2(+)OUT 0 CH2(+)OUT Features by RLCD RLCD-C RLED-C RLED24 SUPPLY 0CH2(-)our 0CH2(-)OUT model 24 VDC+0- —0 24V(0)IN —0 24V(0)IN --- 24VDC-0 024V(-)IN 024V(-)IN Reset _ ✓ ✓ ✓ y 24V(+)OUT 0 24V(+)OUT ACWSilence ✓ ✓ ✓ - 9 24V(-)OUT 0 24V(-)OUT Fire Alarm ✓ ✓ ✓ 0 GROUND 0 GROUND Supervisory ✓ ✓ ✓ - 3141, Ground Fault ✓ ✓ ✓ - Trouble ✓ ✓ ✓ - Controls Enabled ✓ ✓ ✓ - Expander AcWSilence ✓ ✓ ✓ - Reset ✓ / Annunciator First Expander Second Expander -✓ Signal Silence ,i OUT IN OUT IN OUT V(-)0 0v(-i v(-)0 -0vl-) v(-)0 Drill ✓ ✓ - V(+)0 0 v(+) v(+)0 -0 vol v(+)e Lamp Test ✓ ✓ ✓ - F0 OF F0 OF F0 LCD Display ✓ ✓ - - E0 08 E0 -0E E0 Zone Active LEDs - - 16 0 24 00 D 0 0 D D 0- -0 0 0 0 Zone Trouble LEDs - 16 24 c° °c CO- °c CO zones 13-16 may be selected as Supervisory on 1064 B° 0 e e a---------- - e B B° xc zones 13-16 and 29-32 may be selected as Supervisory on/0500 n° °A A 0 n a° Graphic Annunicator Interface The GCI Graphic Annunciator Driver is an interface card that connects the fire alarm control panel to the display panel of an Remote Keyswitch LED-based graphic annunciator. Annunciator LSRA-RK The annunciator card supports 32 LEDs and 16 switches on the J KEYSWITCH(-)0 0 TB1.1 graphic panel display. It includes status LEDs and an internal O KEYSWITCH(+)° ere+-z 4r buzzer. - -- The graphic interface is supplied with snap track mounting. It is Keyswitch Specifications :tnIG attached to a plastic mounting rail that requires two EIA panels. Maximum 5 Vdc ' voltage The annunciator communicates with the FACP on the RS-485 Maximum 200 mA data riser.This can be configured for Class A or Class B commu- current nication.The annunciator does not provide ground fault isolation. Mounting 2-1/2 in(64 mm) It is a stand-alone unit that can be powered by the FACP or by an deep 1-gang box11.111!...\ Wapproved power supply. Termination Screw terminals "'V Maximum 12 AWG Graphic Annunciator Interface Specifications wire size (2.5 m_msq)Alarm current 146 mA at 24 Vdc(with 36 LEDs ON) Contact Normally open �,� ,., ,i'', Standby current 36 mA at 24 Vdc(with no LEDs ON) configuration ',t Maximum current 10 mA per LED Page 2 of 4 85005-0128 Issue 2 Annunciator Connections Annunciator Mounting Annunciator ANNUNCIATOR RS-485 RISER / Mounting slot- /7----'--0 • DIP switch • ) 7::;,;: Il :' Remote keyswitch RS-485 ser terminals -� _____ 0 terminals Expander cable Power terminals '',,1. Iterminals �--"' ° Communication '- . 0 LEDs o ® o Expander 0 Mounting slot � `... Bi '.....{ ® QC .h - EXPANDER CABLE l FL Expander cable l � I l f Expander cable ) terminals w} i }" terminals J » a O %, ... _ j ° DIP switch settings _���N 0 .... _ Switch Description and values 0 Si 0 to S5 The annunciator network address(in binary). \� Network The factory setting is for address 2. address Examples:10000=1 01000=2 11000=3 00100=4 (I)-1 S6 Network OFF=9600 baud(factory default setting) A________ C 1 1 L3 baud rate _ON=38,400 baud S7 to S8 Not used MOUNTING RING EXPANDER ELECTRICAL BOX Annunciator Enclosures The RA Remote Annunciator Enclosures provide secure,surface mounted protection for annunciators and extenders. Each con- sists of a back plate, hinged cover,and key lock. The enclosures are 16-gauge welded steel with a white, painted 6.0 in finish. Each enclosure includes a security lock and two keys.The . 15.2 cm two-and three-position enclosures have wiring channels for cor- H rect routing of interconnections. The enclosures attach to a standard electrical box,and provide a 1 D lift 0 mounting lip that takes the place of the integral mounting ring sup- 1 plied with the annunciators and expanders. L0.9 in 2.3 c • 0819 R4-ENC 1 ) H9.5 in .1 24.1 cm . 2.0 in 9.8 in 5.1 cm 24.9 cm 66996 ) Dimensions(H x W x D) RA-ENC1 6.3 x 9.8 x 2.0 in(16.0 x 24.9 x 5.1 cm) RA-ENC2 12.0 x 9.8 x 2.0 in(30.5 x 24.9 x 5.1 cm) RA-ENC3 17.7 x 9.8 x 2.0 in(45.0 x 24.9 x 5.1 cm) RA-ENC3 Note:Allow approximately 2 inches(50 cm)clearance on both sides of the enclosure,to permit inserting and removing the key,and opening the door RA-ENC2 through 90 degrees. Page 3 of 4 85005-0128 Issue 2 Specifications � Qler r ` RLCD-C mop RLED-C RLED24 y*11•41Todn,, „ Operating voltage 24 VDC,continuous. Standby current 99 mA 98 mA 28 mA 6 mA Contact us... Alarm current 115 mA 113 mA 62 mA 34 mA Email: edwaest-fire@fs.utc.com Web: w.est- wwfire.com RS-485 communications Class A or Class B,9600 baud EST is an EDWARDS brand. Data wiring 18 to 14 AWG(1.0 to 2.5 sq mm)twisted pair(6 twists per foot minimum).Maximum wire run is 4,000 ft.(1,219 m) 1016 Corporate Park Drive Remote key switch circuit 5 VDC at 1 mA,power-limited,unsupervised Mebane,NC 27302 Ground fault impedance 0 In Canada,contact Chubb Edwards... Email: inquiries@chubbedwards.com Power wiring 18 to 14 AWG(1.0 to 2.5 sq.mm) Web: www.chubbedwards.com Display area 4 lines of 20 characters each ©2013 UTC Fire&Security Americas Dimensions(H x W x D) 5-5/8 x 8-1/2 x 1-1/2 in.(14.3 x 21.4 x 3.8 cm) Corporation,Inc.All rights reserved. Specifications subject to change Mounting North American 4-inch square electrical box or listed enclosure without notice.Edwards is part of UTC Agency Listing UL,ULC Climate,Controls&Security,a unit of United Technologies Corporation. Operating environment Temperature:32 to 120°F(0 to 49°C)Humidity:0 to 93%RH, noncondensing at 90°F(32°C) Ordering Information Part Description Remote Annunciators RLCD LCD text annunciator without common controls.English. RLCD-R LCD text annunciator without common controls.English.Red. RLCDF LCD text annunciator without common controls. French. RLCD-C LCD text annunciator with common controls. English. RLCD-CR LCD text annunciator with common controls.English.Red. RLCD-CF LCD text annunciator with common controls.French. RLED-C 16-pair LED zone annunciator with common controls.English. RLED-CR 16-pair LED zone annunciator with common controls.English.Red. RLED-CF 16-pair LED zone annunciator with common controls.French. Remote Expanders RLED24 24-pair LED zone expander with expander cable and zone card insert. RLED24R 24-pair LED zone expander with expander cable and zone card insert.Red. Enclosures RA-ENC1 One-position enclosure for Remote Annunciator. RA-ENC2 Two-position enclosure for Remote Annunciator and one Remote Expander, including one interconnection cable. RA-ENC3 Three-position enclosure for Remote Annunciator and two Remote Expanders, including two interconnection cables. LSRA-SB Surface Mount Box-for single R Series annunciator. Graphic Annunciator Drivers GCI Graphic Annunciator Driver,provides outputs for common indicators and 32 alarm/ supv zones as well as inputs for common switches.Provided with a snap track for mounting in custom graphic enclosures. Accessories RKEY Remote key switch on plate for enabling or disabling common controls(Lock/ Unlock). 27193-16 Electrical box,surface mount,white,single-gang,for RKEY. O 85005-0128 Page4of4 r;ATA :- f�;=: Nr,. be uscd for,,,.,ta14u Issue 2 k"‘. * SIGNALING ' V U` LISTED ACE-12 F F DRAWING STORAGE BOX I I The DSB (Drawing Storage Box) is an ideal solution R R to safely secure your critical building emergency E E plans such as evacuation and building layout drawings. In the event of an emergency, you are A A assured that responders will have immediate L L access to the proper drawings and information A A required. A critical and responsible component to �-Rsiness card anyEOP (Emergency Operation Plan R R `, �": slots ( 9 Y p ). M M -Velcro strap The DSB (Drawing Storage Box) is engineered using 18 gauge cold rolled steel and coated with a 0 durable RED epoxy powder coat finish. A full length E-Tab for hanging stainless steel hinge provides a long lasting durable C C j keys or USB construction. One inch tall lettering silk-screened U U drives with permanent white indelible ink on 2 sides M M provides a full 180 degrees of viewing for immediate E E identification to emergency responders. N N T T The DSB (Drawing Storage Box) securely holds up S S to a 4" diameter 36" tall Architectural roll of drawings. With an industry standard key lock, the cabinet provides secure storage from improper Standard Features: access or removal of critical documentation. An additional retainer inside the box holds drawings • Dimensions: 37" tall x 5 1/2 x 4 %4 deep securely upon opening the door. This cabinet also • Durable 18 gauge steel construction allows space to store other critical disks, USB • Continuous stainless steel hinge drives, keys and contact information for the system. • Color red, powder coat texture finish • 1" white indelible lettering • Standard key lock to secure documents • Hold a 4" dia 36" long roll of drawings • Storage locations for digital media, keys and contacts BOX 1'4 -%Wool- ISO 9001 Space Age Electronics, IncLW . FIRE REGISTERED www.8sae.com NFPIC COMPANY 800.486.1723 Toll Free MEMBER Made In U.S.A. 508.485.0966 Local 508.485.4740 Fax Space Age Electronics, Inc. 2013 ED0572 LT10597 Rev.B 1/2 No Excuses, Just Solutions! 71- SPACE AGE ELECTRONICS, INC. 1 , . F Specifications: fi The Drawing Storage Box (DSB) shall be UL listed, constructed of 18 gauge cold rolled steel (CRS), it shall be painted with a durable red powder coat paint. Over all [ E dimensions 37" tall 5 1/2 wide and 4 '/4" deep. The access door shall be lettered on 2 angled sides of the cabinet providing 180 degrees of viewing. "FIRE ALARM Q G� DOCUMENTS" in White indelible letters minimum of 1" in height. The door shall have a stainless steel continuous piano hinge. The door of the DSB shall be locked with a �, Q keyed lock %" barrel. Inside the cabinet shall have a IR R strap to secure drawing in cabinet that is adjustable for size of rolled drawings. Location to hold keys and secure emergency contact information safely inside cabinet for ) UJ easy access. O O C� C� V Ordering Information : Part # Description . S S SSU00625 Drawing Storage Box (DSB) BOX Space Age Electronics, Inc. www.lsae.com . 5 1/2" -4'' 4 Free 86.172 3 Toll o 508.485.0966 Local 508.485.4740 Fax This document is subject to change without notice,see doc#ED0479 for legal disclaimer No Excuses, Just Solutions! ED0572 LT10597 Rev.B 2/2 —nu,rz"r1NNkVN x i r'i6 \a�!d pi t\ i f Ili i�01 1:11,#„.rr,„.614.1,,4 \,,, iNV164§0!6°16U4 :�Ati V \v \� 0 �, ipip �� a �r is � �A tip., ��11 n 4�,!\ A I 6. `;�` "�\Y��� � � �� ," � , �„� � �, � Q e�� � H� ilige lej paauenpy •% aainaas aelnlla� paen6lal eu!luo paen6lal •elap aa1e1 e ie ''ed alas o� pepea6dn pue y�ed dn�laeq e se pailelsu1 eq osle uea SQL Jl aul •apoua uo!s!naadns a�nu!ua �C x!s Mau ay4041 �o esneaeq SQL Jl al6uls e ao� paddeMs eq uea seu!Ipuel Ile `suol}elle�su! 6uilsixe a0 J 'SUOIleIIelSUi aal lelaaaUaLUOa ao� ied egos eLl} se peIIe su! eq uea SQL Si ay} `e6e�no ue �o sa�nulua �C�xls u!y�!M uo!�e�s lea uaa aye o� saanl!e3 leu6!s 01 alge 6ulaq A8 •saseaaaap meg suo!lealunwwOD cluluow auk `SQL Jl e y�!M paaeldaa au!lpuel yaee and eu!lpuel pa�ealpap e uey� ssal �l}uea!�!u6ls aesn pua aye S SOa 6u!a0}!uoua aelnllaa 'a6eaane g up Alun loa�uoa ae seua aye o� peleD!pap �Cl�uaaana seullpuel.ay1 4o Ile saaeldaa 11 weis�Cs waele aa!� aye ao� qied suo! ealunuauaoa alos aye se an uea SQL Jl aU� 'ZL VddN 3O uO!�!pg £1OZ a4�4�1M �uellduao� Q , UOI�eiS 6UI IOlIUOU1 peieu6!sap aye o� >IaOMleu aeln!{aa le}l6lp aye aano hued aa!j aye UJOa; sleu6!s uaaele s luasuea SQL Jl aul suaa4s�Cs aal leiaait._ ewwoa aoj uo!�nlos suo!;ealun�uuaoa uaaele aelnlla� leap! auk s! SQL Jl paen6lal eq algel!ene ;,us! 1l OM au J�/J� e 4! CWS9) JZ O1 >iaeq SII e� _.ifi s3L-0.1. . . .. 11, s�sa�-blas ao sq., ed en 6u! !Woad �C suaae a es a saz!ua!u! 1,1 dI p p q I I d W •aelnllaa •aano UOl�eal�la2A aa10n /CeM-OMS `u!-ua�s!i s�aoddnS s>IaOMlou £W/O� uo saieaado fey} �c6olougDe 6u!6eaanel icq uo!}aaload 2�W2i sap!noad •suo!�eaiunuauaoa Bled dn�laeq ao �Caeua!ad `alos ao sluauaaa!nbaa egg lf1 s}aaW .� Sg2inl`d3� lDna0ad 3dI.d �VIDd WW0D p s�dc�n�l3� tr/ � god �os��[�1 �N/d d 2i d fl J 131 kid do `di y dV1nh133 ,,,,,.,!\\\,,v4,,s,",,, grallOZLt paniased s4g6la Ird•uolpeJodJoJ Aerial ZL0011.16iJAdoo.woa•pJen6 apsAm n.S uo!1d0'9Z£Z-6ZZ-008 vsn •6££0£V9`e1ue11y•00£al!nS•pnl8 puelaagwn�SZZ£•nl JalueD puepagwnj.uoileJodJo3 Jena'Jo uois!nia e'pJen6lal Pm pp 1VMNOILVN1131N1 a3J.V'1 �\,\\\\ %�C�\\\\ \�P\N\, ,,auued 3!aaees angnOaz3 1114/ .ddJN 3�wapp ..NOIltlIOOSStl i�� °:. sh,wv ,, ,,, OINO211O313 ���— MI �:1 15 "kt\\,„\*",: ‘' \4'',..\ n\Orin"Otiq*k\I woo pJen6layrnnnnn aisin s6ups111n pue suoiaeoiJpads pnpoid 4uanno sow eya.10j S81JAJas Ic11JnDas aUll ' 'S1!Un w.Jele Jeleunq uo!lels leJ1uej • 0191 swals�Cs 0 :�AvAv \V\\,•;, pue s1!un wJele swals�Cs uaJele � r \�`� swalsAs 6U!UIS n Jel6Jnq palaauuoa aJil JoJ saIaossaDDe n. aJlJ plogasnoH • S86 uopelS aallod • 99£ S!un lo.quoD • 1798 \\ lePuap!saa AJe16Jn8 le!aJawwo3 aJ!d lepJawwoD SSUgS11 in ne;aQ eolsAll euue1ue euJe X ova"e ovoovv v,vp�vp I � 3 :0-aX3 � �\� •euue ue leuol1DeJlp u!e6 g6!H :0-a9H • .ejgeD eJuewJoped LL6!q `ssol Mol 40 4aaj OOL/OS/S£/Zl :00L aDd `05 GDV `52 aDd 'EL a0v ‘,11111(' )aq‘14,00190041etlgelltlYSA se!.lossaaay .pajs11 in pue lealulouoDe `Ile}sul of Asea ale s1anpoad pien610l .uone.gaued 6ulpllnq-u! JoLAedns JOJ Jerrod 6U! ji asueJ} L.UnWlxeW pue slle;ap leu6ls 4ulod-o4-1ulod pallwllun J04 6ul4Jodaa elep lin; snnolle ,C6olouyae: pJen613l tss ,\PNI% ,,‘‘AV ‘v,0"",\,"0,„,,,,,o '''t"wAm(IeuolidO) au!IPue1 a.la uoliel5 le]uaJ ' _ W aivaW sleonlaN uo lei un wok ^Ilan 9, 01 will 1 1 Pienelal ow./9Z 10 0 q) s>Id0M13N 17/92 d t�OS JOL9i N/d ad 's/ 110131 d 01 D f N 0 J SJL-Oi \1 kidviv dV1fh -13 D N l�. V) LU U LU 0 0 LU U- I Intelligent Initiating EST Life Safety & Communications . ., it: ''''::, i� a' Manual Pull PULL_ �� IN CASE StationsE FIR , SIGA-270, SIGA-270P, a PULL FOR SIGA-278 � � ° �' t t> _ SIGA 2 O SE,°.ES Patented MIR 0 Q. , MEA ® 7150-1657: O 0129 S2318 Overview • Break glass operation The SIGA-270 and SIGA-278 series Manual Pull Stations are An up-front visible glass rod on the SIGA-270 discourages tampering. part of EST's Signature Series system.The SIGA-270 Fire Alarm Manual Pull Stations feature our very familiar teardrop shape.They • Intelligent device with integral microprocessor are made from die-cast zinc and finished with red epoxy powder- All decisions are made at the station allowing lower corn- coat paint complemented by aluminum colored stripes and mark- munication speed while substantially improving control panel ings. With positive pull-lever operation,one pull on the station response time. Less sensitive to line noise and loop wiring handle breaks the glass rod and turns in a positive alarm,ensuring properties;twisted or shielded wire is not required. protection plus fool-proof operation. Presignal models(SIGA-270P) . ADA Compliant are equipped with a general alarm(GA)keyswitch for applications Meets ADA requirements for manual pull stations. where two stage operation is required.The up-front highly visible glass rod discourages tampering, but is not required for proper • Electronic Addressing with Non-volatile memory operation. Permanently stores programmable address,serial number, type of device,and job number.Automatically updates historic EST's double action single stage SIGA-278 station is a contempo- information including hours of operation, last maintenance rary style manual station made from durable red colored lexan. To date, number of alarms and troubles,and time and date of last initiate an alarm,first lift the upper door marked"LIFT THEN PULL alarm. HANDLE",then pull the alarm handle. • Automatic device mapping Each station transmits wiring information to the loop control- Standard Features ler regarding its location with respect to other devices on the Note:Some features described here may not be supported by all control sys- circuit. tems.Check your control panel's Installation and Operation Guide for details. • Stand-alone operation • Traditional familiar appearance The station inputs an alarm even if the loop controller's polling SIGA-270 models feature our familiar teardrop design with interrogation stops. simple positive pull action and sturdy die-cast metal body. • Diagnostic LEDs • One stage(GA),two stage(pre-signal),and double action Status LEDs;flashing GREEN shows normal polling;flashing models RED shows alarm state. SIGA-270 models are available for one or two stage alarm • Designed for high ambient temperature operation systems.The single stage double action SIGA-278 features a Install in ambient temperatures up to 120°F(49°C). rugged Lexan housing with keyed reset mechanism. Page 1 of 4 85001-0279 Issue 8 Application Typical Wiring The operating characteristics of the fire alarm stations are deter- The fire alarm station's terminal block accepts#18 AWG(0.75mm2) mined by their sub-type code or"Personality Code". NORMALLY- to#12 AWG(2.5mm2)wire sizes.See Signature Loop Controller OPEN ALARM-LATCHING(Pesonality Code 1)is assigned by the catalog sheet for detailed wiring requirement specifications. factory;no user configuration is required.The device is configured for Class B IDC operation.An ALARM signal is sent to the loop Wiring Notes controller when the station's pull lever is operated.The alarm con A Refer to Signature Loop Controller manual for maximum dition is latched at the station. wire distance. 2. All wiring is power limited and supervised. Compatibility REARVIEW of 278 Signature Series manual stations are compatible only with EST's e Signature Loop Controller. p 0 0 r� 4 lain Warnings & Cautions a2 i 3 ". This device will not operate without electrical power.As fires fre- quently cause power interruption,we suggest you discuss further Red LED 4 Green LED (Alarm/Active) I ® © (Normal) safeguards with your local fire protection specialist. _" ' 2 ' O TBl'l_pl ll—I_I�i. 0 Ha Testing & Maintenance -11=■1■1111111111_ To test(or reset)the station simply open the station and operate DATA IN(+) ml 1 DATA OUT(+) the exposed switch.The SIGA-270 series are opened with a tool; {DATA IN(-) I DATA OUT 1-) the SIGA-278 requires the key which is supplied with that station. From Signature Controller To Next Device or Previous Device 0 The station's automatic self-diagnosis identifies when it is defec- tive and causes a trouble message.The user-friendly maintenance Figure 4. Single Stage Systems program shows the current state of each Signature series device and other pertinent messages. Single devices may be deactivated temporarily,from the control panel.Availability of maintenance REAR VIEW features is dependent on the fire alarm system used. of Scheduled maintenance(Regular or Selected)for proper system 270P,270PB ® 1=00 operation should be planned to meet the requirements of the - .er o Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and r=te ULC CAN/ULC 536 standards. TB2 110 4. (n "lN 8 7 6 5 • • • Red LED Green LED (Alarm/Active) 9 4 3®7 0 (Normal) TB) ' U II I .8.' 0 .1 i 0 O i '!FI h {(DATA IN(+) I IIDATA OUT(+) l DATA IN(-) , DATA OUT(-)f -- - - - - - -- - - - -_ — - __"`— From signature Controller To Next Device or Previous Device A Figure 5. Two Stage Systems Page 2 of 4 85001-0279 Issue 8 Installation Single-stage Signature Series fire alarm manual pull stations mount to North American 21/2 inch(64 mm)deep 1-gang boxes. Two stage presignal(270P)models require 11 inch(38 mm)deep 4-inch square boxes with 1-gang,'/2-inch raised covers.Openings must be angular.Rounded openings are not acceptable. Recommended box:Steel City Model 52-C-13;in Canada,use Iberville Model Cl- 52-C-49-1/2. All models include terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Edwards recommends that these fire alarm stations be installed according to latest recognized edition of national and local fire alarm codes. Electronic Addressing: The loop controller electronically addresses each manual station,saving valuable time during system com- missioning.Setting complicated switches or dials is not required. Each station has its own unique serial number stored in its on-board memory.The loop controller identifies each device on the loop and assigns a"soft"address to each serial number. If desired,the stations can be addressed using the SIGA-PRO Signature Program/Service Tool. 40, Key-Latch III Voit,Compatible Electrical Box �w Cover Release Compatible Electrical Box 0 0 Cover A, ,7,,.;, ' Release `0"1"' \0 ► Screw ''°' II WI co Oa ° v oeuetavak/ 00Q L* 1 a E \,'II Back \ FIR i \/ 0 �`. Pate E �-, 1 0 0‘`, Back FIR �� o Plate i /# \ ° Toggle ``�• Toggle ° O ORM-t>> r o Switch 'f, 1 s. lit.. /V/ \ o a \ C � Glass Rod ^ ,�vVv" �������� V v�\ v . �1 Glass Rod �� Release Lever li OPEN \ \11.11111\, 00 0 \7000,,z,,,,‘ Figure 1. SIGA-278 installation Figure 2. SIGA-270,SIGC-270F,SIGC-270B installation Cover Release qOV Scr Compatible A\v\ v iv�V�J ��^^^� Electrical Box ei) ; withiza v vA l \,u ,„, , , raised covers \ pa5. ow i \\ / ! '. 51 0 \\\�°;o \\ ti m" Q ° V���v\ \� 0Back A ,m o ° Plate A\ W�11rr"4 Toggle I ��R ° Switch , NORMpL L o O 1< , S Glass Rod _._.__ ` Release Lever Donot use bo �`+ boxes with V roundedklk\IIIIIP..\, openings. \fit Figure 3. SIGA-270P,SIGC-270PB installation Page 3 of 4 85001-0279 Issue 8 Specifications C DV�. DS SIGA-270,SIGC- SIGA-270P, ,� t Catalog Number 270F,SIGC-270B SIGC-270PB SIGA-278 Description Single Action Single Action-Two Double Action Contact us... -One Stage Stage(Presignal) -One Stage Email: edwards.fire@fs.utc.com Addressing Uses 1 Module Uses 2 Module Uses 1 Module Web: www.est-fire.com Requirements Address Addresses Address EST is an EDWARDS brand. Operating Current Standby=250pA Standby=396pA Standby=250pA Activated=400lA Activated=680lA Activated=400lA 1016 Corporate Park Drive Mebane,NC 27302 Construction&Finish Diecast Zinc-Red Epoxy Lexan-Red with with aluminum markings white markings In Canada,contact Chubb Edwards... Type Code Factory Set Email: inquiries@chubbedwards.com Web: www.chubbedwards.com Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Operating Temperature:32°F to 120°F(0°C to 49°C) ©2013 UTC Fire&Security Americas Storage and Operating Storage Temperature:-4°F to 140°F(-20°C to 60°C)Humidity:0 to 93% Corporation,Inc.All rights reserved. Environment Specifications subject to change RH without notice.Edwards is part of UTC On-board Green LED-Flashes when polled Climate,Controls&Security,a unit of LED Operation On-board Red LED-Flashes w hen in alarm United Technologies Corporation. Both LEDs-Glow steady when in alarm(stand-alone) .���,,WM... Compatibility Use With:Signature Loop Controller Agency Listings UL,ULC(note 1),MEA,CSFM Note:SIGC-270F,SIGC-270B and SIGC-270PB are ULC listed only.Suffix'F"indicates French markings. Suffix"B"indicates English/French biting ual markings. Ordering Information Ship Catalog Wt.lbs Number Description (kg) 1 SIGA-270 One Stage Fire Alarm Station, English Markings-UL/ULC Listed SIGC-270F One Stage Fire Alarm Station, French Markings-ULC Listed SIGC-2708 One Stage Fire Alarm Station,French/English Markings-ULC Listed SIGA-270P Two Stage(Presignal)Fire Alarm Station, English Markings-UL/ULC Listed 1 (0.5) SIGC- Two Stage(Presignal)Fire Alarm Station, French/English Markings 270PB -ULC Listed SIGA-278 Double Action(One Stage)Fire Alarm Station,English Markings -UL/ULC Listed Accessories 32997 GA Key w/Tag-for pre-signal station(CANADA ONLY) 276-K2 GA Key-for pre-signal station (USA ONLY) 276-K1 Station Reset Key, Supplied with all Key Reset Stations 0.1 (.05) 27165 12 Glass Rods-for SIGA-270 series(CANADA ONLY) 270-GLR 20 Glass Rods-forSIGA-270 series (USA ONLY) 276-GLR 20 Glass Rods-for SIGA-278 series 276B-RSB Surface Mount Box,Red-for SIGA pull stations 1 (0.6) O 7' N Page 4 of 4 85001-0279ai Issue 8 Intelligent Input-Output tt EST - Life Safety & Communications Synchronization = - Output Module SIGH—CCI S, MCC1 S `,4 Y -` o % Agi r iii _ • : ._. 1 ,I a .._ Patented „.. , . , 0 (0 0i", F.re.2 MEA 73000-2657: S3424 Overview Standard Features SIGA-CC1 S and MCC1 S Synchronization Output Modules are • Provides UL 1971-compliant auto-sync output for visual intelligent analog addressable devices that form part of EST's signals Signature line of products.The actual operation of the SIGA-CC1 S Use for connecting a supervised output circuit to a supervised and MCC1 S is determined by the"personality code"selected by 24 Vdc riser input and synchronizing multiple notification appli- the installer,which is downloaded to the module from the Signa- ance circuits. ture loop controller during system configuration. • Functions as an audible signal riser selector Depending on their assigned personality,Synchronization Output Use as a synch module or for connecting supervised 24 Vdc Modules may be used as a signal power riser selector to provide AudibleNisible signal circuits,or 25 and 70 VRMS Audio synchronization of fire alarm signals across multiple zones,or for Evacuation and Telephone circuits to their power inputs. connecting,upon command from the loop controller,supervised • Built-in ring-tone generator Class B signal or telephone circuits to their respective power When configured for telephone circuits,the SIGA-CC1 S gener- inputs.The power inputs may be polarized 24 Vdc to operate au- ates its own ring-tone signal,eliminating the need for a sepa- dible and visible signal appliances or 25 and 70 VRMS to operate rate ring-tone circuit. audio evacuation speakers and firefighter's telephones. • Automatic device mapping Signature modules transmit information to the loop controller regarding their circuit locations with respect to other Signature devices on the wire loop. • Electronic addressing --- - _ — Programmable addresses are downloaded from the loop con- troller,a PC,or the SIGA-PRO Signature Program/Service Tool; there are no switches or dials to set. • Intelligent device with microprocessor All decisions are made at the module to allow lower com- munication speed with substantially improved control panel response time and less sensitivity to line noise and loop wiring properties;twisted or shielded wire is not required. Page 1 of 4 85001-0543 Issue 3.1 Application Installation The SIGA-CC1S mounts to a standard North American two-gang The SIGA-CC1S:mounts to North American 2-1/2 inch(64 mm) electrical box,making it ideal for locations where only one module deep 2-gang boxes and 1-1/2 inch(38 mm)deep 4 inch square is required.Separate I/O and data loop connections are made to boxes with 2-gang covers and SIGA-MP mounting plates.The each module. terminals are suited for#12 to#18 AWG(2.5 mm2 to 0.75 mm2) The SIGA-MCC1S is part of the UIO family of plug-in Signature wire size. Series modules. It functions identically to the SIGA-CC1 S, but takes advantage of the modular flexibility and easy installation that characterize all UIO modules.Two-and six-module UIO mother- • boards are available.These can accommodate individual risers for each on-board module,or risers that are shared by any combina- tion ombina tion of its UIO modules.All wiring connections are made to termi Q' j nal blocks on the motherboard. UIO assemblies may be mounted �' -��f in Edwards enclosures. Q',.A Personality Codes / The operation of the SIGA-CC1 S is determined by their sub-type code or"Personality Code".The code is selected by the installer SIGA-MCC1S:mount the UIOxR motherboard inside a suitable depending upon the desired application and is downloaded from Edwards enclosure with screws and washers provided. Plug the the loop controller. module into any available position on the motherboard and secure Personality Code 5:Signal Power or Audio Evacuation(sin- the module to the motherboard with the captive screws.Wiring gle riser).Configures the module for use as a Class B Audible/ connections are made to the terminals on the motherboard(see Visible Signal power(24 Vdc polarized)or Audio Evacuation(25 wiring diagram). UIOxR motherboard terminals are suited for#12 or 70 VRMS)power selector.The ring-tone generator is disabled. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. The output circuit is monitored for open or shorted wiring. If a U10 Motherboard short exists,the control panel inhibits the activation of the audible/ s-32 visible signal circuit to prevent connection to the power circuit. self-tapping screws Personality Code 6:Telephone with ring-tone(single riser). Configures the module for use as a Telephone power selector. --' 1--4 4 When a telephone handset is plugged into its jack or lifted from its (Ul0)` Captive hook,the module generates its own Ring-Tone signal.A separate Module screws ring-tone circuit is not needed.The module sends this signal to "`� fl--1* the control panel to indicate that an off-hook condition is present. — , When the system operator responds to the call,the ring-tone #6 Flat washers signal is disabled. 4—Cabinet or electrical enclosure Personality Code 25:Visual Signal Synchronization.This — personality code configures the module to provide synchronization of fire alarm signals across multiple zones. It functions as a signal power(24 Vdc)riser selector.The output wiring is monitored for Electronic Addressing open circuits and short circuits.A short circuit will cause the fire The loop controller electronically addresses each module saving alarm control panel to inhibit the activation of the audible/visual valuable time during system commissioning. Setting complicated signal circuit so the riser is not connected to the wiring fault. switches or dials is not required. Each module has its own unique serial number stored in its"on-board memory".The loop control- ler identifies each device on the loop and assigns a"soft"address Warnings & Cautions to each serial number. If desired,the modules can be addressed This module will not operate without electrical power.As fires fre using the SIGA-PRO Signature Program/Service Tool. quently cause power interruption,we suggest you discuss further safeguards with your fire protection specialist. Testing & Maintenance Edwards recommends that these modules be installed according The module's automatic self-diagnosis identifies when it is defec- to latest recognized edition of national and local fire alarm codes. tive and causes a trouble message.The user-friendly maintenance program shows the current state of each module and other perti- nent messages.Single modules may be turned off(de-activated) Compatibility temporarily,from the control panel. The Synchronization Output Module is compatible with EST's Sig- Scheduled maintenance(Regular or Selected)for proper system nature Loop Controller operating under EST3 version 2.0 or higher, operation should be planned to meet the requirements of the and QuickStart Signature Loop Intelligent Controller. Authority Having Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ULC 536 standards. Page 2 of 4 85001-0543 Issue 3.1 Typical Wiring SIGA-CC1S(Standard Mount) SIGA-MCC1S(UIO Mount) Personality Typical Speaker Circuit Personality Typical Speaker Circuit Code 5 Code5 :14 N4 .3 47KW EOLted NSI RI ._ 47KW EDLted Personality Typical Telephone Circuit Personality Typical Telephone Circuit Code6 Code 6 —�� C C C =CEO—reded C C C 47KW EOLted Personality Enhanced Integrity and Genesis Devices Personality Enhanced Integrity and Genesis Devices Code 25 Code 25 O r UL/ULC Listed 47KW EOL ©4 47KWOL E ted 1234 F '`:'{ La WOW)series motherboard 10 9 Data Int� -`E —.+Riser 1 Out • IX. z—(- CC1S siganoa�re� i 0 000 sio rte+ Riserlm Circuit B 7 (J 5 4 3 2 1 + Data Oat 0N14\0 _.I Ilk 6661 Tel 01, WV Green LED(Normal) „, .Riseroutl+) Red LED lActivel d4ktk4N Teis To next device "iii' .Riser out 1-) 1 2 3 4 Riser in 1+1 t From control panel .Data out 1+I Riser 1 In-1-1 I I L' Riser 1 Out To next device or EOL resistor. �+ Riser in I-1 ) Data out I-I Data in 1+) ) From signature Controller Data in 1-) or Previous Device Multiple CC1(S)modules using the BPS's sense inputs T61 Notification appliance circuit(NAIC) 1/ + a Dia EOL AU aE AUX1 - OLLUL 15 KW NAC2/ AUX2 - a Notification appliance circuit(NAC) NAAU 3/ + a DMZ E listed AU aE AUX3 - OL 15 KW NAC4/ + © AUX4 - a 200 mAAUX Lo a Continuous m at INI©-+ Sense 1 COM I� EOL 47 K OUT IlJ INI® + Sense 2 COM I QJ,^ • OUT @ - EOL 47 K��y� NO ® j pul® 1 1 Li Trouble COM J 109 109 NC ©J TB20 CC1(S)module CC1(S)module 0 0 0 0 'I8765 4321 8765 4321 amt 410[110 I 11 ul[ III[1]1111 _. --►[3] Page 3 of 4 85001-0543 Issue 3.1 .. << Specifications '' EDWARD9 Catalog Number SIGA-CC1S SIGA-MCC1S O,iralto aTIN wWWI . North American 21/2 inch(64 mm) deep two-gang boxes and 11/2 Plugs into UIO2R,UIO6R or U106 Contact us... Mounting inch(38 mm)deep 4 inch square Motherboards Email: edwards.fire@fs.utc.com boxes with 2-gang covers and Web: www.est-fire.com SIGA-MP mounting plates EST is an EDWARDS brand. Description Synchronization Output Module 1016 Corporate Park Drive Type Code 50(factory set) Mebane,NC 27302 Address Requirements Uses one module address In Canada,contact Chubb Edwards... Wiring Terminations Suitable for#12 to#18 AWG(2.5 mm2 to 0.75mm2) Email: inquiries@chubbedwards.com OperatingCurrent Standby=223pA Web: www.chubbedwards.com Activated=1 00pA ©2013 UTC Fire&Security Americas Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Corporation,Inc.All rights reserved. 24 Vdc=2 amps Specifications subject to change Output Rating 25 V Audio=50 watts without notice.Edwards is part of UTC 70 V Audio=35 watts Climate,Controls&Security,a unit of _ United Technologies Corporation. Construction High Impact Engineering Polymer Storage and Operating Operating:32°F to 120°F(0°C to 49°C) Environment Storage:-4°F to 140°F(-20°C to 60°C) Humidity:0 to 93%RH LED Operation Green LED-Flashes when polled Red LED-Flashes when in alarm/ active Compatibility Use with:Signature Loop Controller under EST3 version 2.0 or higher Agency Listings UL,ULC,CSFM,MEA Ordering Information Catalog Description Shipping Wt. Number lbs(kg) SIGA-CC1S Synchronization Output Module(Standard Mount)-UL/ULC Listed 0.5(0.23) SIGA Synchronization Output Module(UIO Mount)-UL/ULC Listed 0.18(0.08) MCC1S Related Equipment 27193-21 Surface Mount Box-Red,2-gang 2(1.2) 27193-26 Surface Mount Box-White,2-gang 2(1.2) SIGA U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) -Two Module Positions SIGA U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) -Six Module Positions SIGA-U106- Universal Input-Output Module Board-Six Module rositioi 0.56(0.25) 235196P Bi-polar Transient Protector 0.01 (0.05) MFC-A Multifunction Fire Cabinet-Red, 7.0(3.1) supports Signature Module Mounting Plates SIGA-MP1 Signature Module Mounting Plate, 1 footprint 1.5(0.70) SIGA-MP2 Signature ModuAfounting Plate, 1/2 011911111 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) O Page 4 of 4 85001-0543 Issue 3.1 Intelligent Input/Output EST Life Safety & Communications High ii ni Control Relay • „„, • . , ary = • Module g SIGA-CRH Description Standard Features The SIGA-CRH High Power Control Relay Module is an address- • High Power Rating able device designed for interface applications that require a high 120/240 VAC or 24 VDC rated contact can be used to control voltage, high current relay.Two identical sets of relay terminals are external appliances such as door closers,fans,dampers etc. provided. Both sets of relay contacts transfer when the module • Provides one relay with two Form C contacts is activated or restored.The state of the output terminals is not Relay accepts 12 to 18 AWG(1.0 to 4.0 mm2)wiring from two supervised. sources The module requires one address on the signaling line circuit • Automatic device mapping (SLC).The address is assigned electronically.There are no ad- Signature modules transmit information to the loop controller dress switches to set. regarding their circuit locations with respect to other Signature devices on the wire loop. • Removable terminal blocks Easy wiring and module replacement. • Electronic addressing Programmable addresses are downloaded from the loop con- troller or PC;there are no switches or dials to set. • Intelligent device Distributed intelligence allows lower communication speed with substantially improved control panel response time and less • aerrainAly to iim-nelm enma Imp wiring prolzor lid twiolud or shielded wire is not required. Page 1 of 4 n A T A S 85001-0644 Not u..od fo. :c. Issue 1 Application Installation Personality code Compatible electrical box Use Personality Code 8 to configure the SIGA-CRH module: / Personality code 8:Signal-dry contact output.Configures ��� SIGH CRH the module as a dry relay contact to control external appli- ances(door closers,fan controllers,dampers)or equipment Shutdown. (� Al Wall plate o / Indication �> I� , The status LED shows the state of the module through the cover `t l ® rd"* plate: o 0 • Normal:Green LED flashes [$' ° o • Alarm/active: Red LED flashes .., Compatibility The SIGA-CRH is part of the Signature Series intelligent process- ing and control platform. It is compatible with EST3, EST3X,and Consult the SIGA-CRH High Power Control Relay Module Installa- i0 Series control panels. tion Sheet for details. Warnings&Cautions The SIGA-CRH will not operate without electrical power.As fires Wiring frequently cause power interruption,we suggest you discuss further safeguards with your local fire protection specialist. Oo O 1 � _J\ EDWARDS recommends that this module be installed according - . to latest recognized edition of national and local fire alarm codes. ° ' 1111 __ I�•�I ��� (3) 71271_ (4) - 5 _ 7 Testing&Maintenance bili Noz �� (6) —( ) SIGA-CRH automatic self-diagnosis identifies when it is defective 'Mil ' Nc; : I1;1 (4) and causes a trouble message.The user-friendly maintenance Olaf = i� (5) -(8) program shows the current state of each module and other per- LI p tinent messages. Single modules may be turned off(deactivated) i'�III'ILI "o 11 (6) - temporarily,from the control panel.Availability of maintenance - o • features is dependent on the fire alarm system used. Scheduled (2) maintenance(Regular or Selected)for proper system operation ( 0 o O should be planned to meet the requirements of the Authority Hav- ing Jurisdiction(AHJ). Refer to current NFPA 72 and ULC CAN/ (1) Signaling line circuit(SLC)from previous device ULC 536 standards. (2) Signaling line circuit(SLC)to next device (3) Power-limited and supervised Electronic Addressing (4) Normally closed contact(NC) The loop controller electronically addresses the SIGA-CRH, saving (5) Common contact(C) valuable time during system commissioning. Setting complicated (6) Normally open contact(NO) switches or dials is not required.The module has its own unique (7) Relay terminal set 2. serial number stored in its on-board memory. Not supervised.Power-limited unless connected to a nonpowerlimited source.If the source is nonpower-limited,eliminate the power-limited mark and maintain a minimum of 0.25 in.(6.4 mm)space from power-limited wiring. For other mounting methods,see enclosure and —— bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring.The wire size must be capable of handling fault current from a nonpower-limited source. —or— Use type FPL,FPLR,FPLP,or permitted substitute cables,provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in.(6.4 mm)space or by a nonconductive sleeve or nonconductive barrier from all other conductors.Refer to the NFPA 70 National Electrical Code for more details. (8) Relay terminal set 1.Identical to(7). Page 2 of 4 85001-0644 Issue 1 Specifications Ordering Information SLC operating voltage 15.20 to 19.95 VDC Catalog Description Ship Weight SLC current Number lbs(kg) Standby 75 pA max. y SIGA-CRH High Power Control Relay Module 0.4(0.15) Activated 75 pA max. Contact ratings[1][2] 240 V 50/60 Hz 7 A(PF 0.75), 1.5 A(PF 0.35) 120 V 50/60 Hz 7 A(PF 0.75),3.0 A(PF 0.35) - -- 24 VDC 6 A resistive Audio switching 0 to 20 kHz[3] Relay type 2 Form C,programmable Relay ready delay 30 s max.(includes initial state set) From power up 5 s max.(one activation) From previous activation 8 s max.(two activations, 1 s apart) Circuit designation Signaling line circuits Class A,Style 6 or Class B,Style 4. Refer to the control panel technical publications for SLC wiring details. Relay circuits Class E Number of SIGA-CRH per SLC 60 max. Wire size 12 to 18 AWG(1.0 to 4.0 mm2) North American double-gang x 2-1/8 Compatible electrical boxes in.(54 mm)deep box North American standard 4 in.square x 2-1/8 in.(54 mm)deep box Agency Listings CAN/ULC-S527,UL 864 Operating environment Temperature 32 to 120°F(0 to 49°C) Relative humidity 0 to 93%,noncondensing Storage temperature_ -4 to 140°F(-20 to 60°C) [1] Provide external fusing and back-EMF mitigation as required by your application.Do not use the SIGA-CRH in a mixed application, where one set of relay terminals has high-power requirements and the other set carries a low-power signal,as this may result in physical contamination of the low-power signal contacts. [2] The minimum load required in order to avoid long-term contact oxidation is 100 mA and 12 V. [3] Power must not exceed the contact ratings shown for a given PF (power factor). Page 3 of 4 85001-0644 Issue 1 Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb EDWARDS... Email: inquiries@chubbedwards.com Web: wwwchubbedwards.com ©2015 United Technologies Corpora- tion.All rights reserved.Specifications subject to change without notice. EDWARDS is part of UTC Building& Industrial Systems,a unit of United Technologies Corporation. A Page 4 of 4 85001-0644 N0 Issue 1 Intelligent Input-Output EST Life Safety & Communications Input Modules _ ., ,L, ,, „, r SIGA-CT1 , SIGA-CT1 HT, SIGA-CT2, SIGA-MCT2 < .3 it 1 ..; SIGA-CT1/2 �/ 0SIGA-MCT2 ® MEA (E0O ii ® Application Notes 7300-1657: Available 0121 S3424 Overview Standard Features The SIGA-CT1 Single Input Module, SIGA-CT1 HT High Tern- • Multiple applications perature Single Input Module and SIGA-CT2/SIGA-MCT2 Dual Including Alarm,Alarm with delayed latching(retard)for water- Input Modules are intelligent analog addressable devices used to flow applications,Supervisory,and Monitor.The installer selects connect one or two Class B normally-open Alarm,Supervisory,or one of four"personality codes"to be downloaded to the mod- Monitor type dry contact Initiating Device Circuits(IDC). ule through the loop controller. The actual function of these modules is determined by the"personal- • SIGA-CT1 HT rated for high temperature environments ity code"selected by the installer.This code is downloaded to the Suitable for attic installation and monitoring high temperature module from the Signature loop controller during system configura- heat detectors. tion. • Plug-in(UIO)or standard 1-gang mount TheUIO versions allow quick installation where multiple modules are input modules gather analog information from the initiating required.The 1-gang mount version is ideal for remote loca- devices connected to them and convert it into digital signals. tions that require a single module. The module's on-board microprocessor analyzes the signal and decides whether or not to input an alarm. • Automatic device mapping Signature modules transmit information to the loop controller The SIGA-CT1,SIGA-CT1 HT and SIGA-CT2 mount to standard regarding their circuit locations with respect to other Signature North American 1-gang electrical boxes; making them ideal for lo- devices on the wire loop. cations where only one module is required.Separate I/O and data • Electronic addressing loop connections are made to each module. Programmable addresses are downloaded from the loop con- The SIGA-CT1 HT module operates at an expanded temperature troller,a PC,or the SIGA-PRO Signature Program/Service Tool. range of 32°F to 158°F(0°C to 70°C)for those applications There are no switches or dials to set. - requiring more extreme environmental temperature variation. • Stand-alone operation The SIGA-MCT2 is part of the UIO family of plug-in Signature The module makes decisions and inputs an alarm from initiat Series modules. It functions identically to the SIGA-CT2,but ing devices connected to it even if the loop controller's polling takes advantage of the modular flexibility and easy installation that interrogation stops.(Function availability dependent upon control characterizes all UIO modules.Two-and six-module UIO mother- panel.) boards are available.All wiring connections are made to terminal • Ground fault detection by address blocks on the motherboard. UIO assemblies may be mounted in Detects ground faults right down to the device level. Edwards enclosures. Page 1 of 4 85001-0241 Issue 8 Signature Series Overview U10 Motherboard 1 6-32 Signature Series intelligent analog-addressable system from Self- tapping Edwards Security is an entire family of multi-sensor detectors and screws mounting bases, multiple-function input and output modules, -- 1---c1---cnetwork and non-network control panels, and user-friendly main- -f_-.0 tenance and service tools.Analoginformation from equipment Plug-in(Ulo) Captive Module screws connected to Signature devices is gathered and converted into - fl--„q digital signals.An onboard microprocessor in each Signature de- ca--1----. - - -1 vice measures and analyzes the signal and decides whether or not fi #6 Flat washers to input an alarm.The microprocessor in each Signature device provides four additional benefits-Self-diagnostics and History _—Cabinet or electrical enclosure Log,Automatic Device Mapping,Stand-alone Operation and Fast, Stable Communication. Electronic Addressing-The loop controller electronically ad- Self-diagnostics and History Log-Each Signature Series dresses each module,saving valuable time during system com- device constantly runs self-checks to provide important mainte- missioning. Setting complicated switches or dials is not required. nance information.The results of the self-check are automatically Each module has its own unique serial number stored in its updated and permanently stored in its non-volatile memory.This on-board memory.The loop controller identifies each device on information is accessible for review any time at the control panel, the loop and assigns a"soft"address to each serial number. If PC,or using the SIGA-PRO Signature Program/Service Tool. desired,the modules can be addressed using the SIGA-PRO Automatic Device Mapping-The Signature Data Control- Signature Program/Service Tool. ler(SDC)learns where each device's serial number address is Edwards recommends that this module be installed according to installed relative to other devices on the circuit.The SDC keeps a latest recognized edition of national and local fire alarm codes. map of all Signature Series devices connected to it.The Signature Series Data Entry Program also uses the mapping feature.With interactive menus and graphic support,the wired circuits be- Application tween each device can be examined. Layout or"as-built"drawing information showing branch wiring(T-taps),device types and their The duty performed by the SIGA-CT1 and SIGA-CT2/MCT2 is de- address are stored on disk for printing hard copy. termined by their sub-type code or"Personality Code".The code is selected by the installer depending upon the desired application Installation and is downloaded from the loop controller. SIGA-CT1,SIGA-CT1HT and SIGA-CT2:modules mount to One personality code can be assigned to the SIGA-CT1.Two per- North American 2t/2 inch(64 mm)deep 1-gang boxes and 11/2 inch sonality codes can be assigned to the SIGA-CT2/MCT2. Codes (38 mm)deep 4 inch square boxes with 1-gang covers and SIGA- 1, 2,3 and 4 can be mixed on SIGA-CT2/MCT2 modules only. For MP mounting plates.The terminals are suited for#12 to#18 AWG example, personality code 1 can be assigned to the first address (2.5 mm2 to 0.75 mm2)wire size. (circuit A)and code 4 can be assigned to the second address (circuit B). NORMALLY-OPEN ALARM-LATCHING(Personality Code 1) 11163X � compatible electrical box -Assign to one or both circuits. Configures either circuit A or B or li both for Class B normally open dry contact initiating devices such as Pull Stations, Heat Detectors,etc.An ALARM signal is sent to CIO the loop controller when the input contact is closed.The alarm � `, condition is latched at the module. Wall plate,white 11111\ 111,-4\ (1-gang) NORMALLY-OPEN ALARM -DELAYED LATCHING(Person- ality Code 2)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact initiat- ing devices such as Waterflow Alarm Switches.An ALARM signal is sent to the loop controller when the input contact is closed for 1/11.\'''^,`�',, C7 approximately 16 seconds.The alarm condition is latched at the , . module. -----__ -_ __. ----- - -.. Status LEDs . �,�`. NORMALLY-OPEN ACTIVE-NON-LATCHING (Personality LED viewing ports • ,0 Code 3)-Assign to one or both circuits. Configures either circuit A or B or both for Class B normally-open dry contact monitoring L.......e....* \ input such as from Fans, Dampers, Doors,etc.An ACTIVE signal p ,� is sent to the loop controller when the input contact is closed.The active condition is not latched at the module. SIGA-MCT2:mount the UlO motherboard inside a suitable NORMALLY-OPEN ACTIVE-LATCHING(Personality Code Edwards enclosure with screws and washers provided. Plug the 4)-Assign to one or both circuits. Configures either circuit A or SIGA-MCT2 into any available position on the motherboard and B or both for Class B normally open dry contact monitoring input secure the module to the motherboard with the captive screws. such as from Supervisory and Tamper Switches.An ACTIVE signal Wiring connections are made to the terminals on the motherboard is sent to the loop controller when the input contact is closed.The (see wiring diagram). UlO motherboard terminals are suited for#12 active condition is latched at the module. to#18 AWG(2.5 mm2 to 0.75 mm2)wire size. Page2of4 DATA sttcc 85001-0241 tvnt t,, na 05n'3 tcr' " ,: Issue 8 Typical Wiring Modules will accept#18 AWG(0.75mm2), #16(1.0mm2),and#14AWG(1.50mm2), and#12 AWG(2.50mm2)wire sizes. Note:Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation.See Signature Loop Controller catalog sheet for detailed wiring requirement specifications. Initiating(Slave)Device Circuit Wire Specifications Maximum Allowable Wire Resistance 50 ohms(25 ohms per wire)per Circuit Maximum Allowable Wire Capacitance i 0.1 pF per Circuit For Design Reference: Wire Size Maximum Distance to EOLR #18 AWG(0.75 mm2) #16 AWG(1.00 mm2) #14 AWG(1.50 mm2) { 4,000 ft(1,219 m) #12 AWG(1.50 mm2) I Typical N.O.Initiating Device Typical N.O.Inflating Device it INPUT 1 INPUT 2 1 cc guin HH Ruin AAAStyle B(Class B) /—PO 1 .■.■, 162 Ili :1 �. I _ ■�■ �� ) TB2 Iain i►►ir (� 8 7 UL/ULC Listed Style B(Class B) • • • 471(1 EOL UL/ULC Listed 8 7 6 5 UL/ULC Listed 471(1 EOL AAA A • • • 471(II EOL Red LED Green LED (Alarm/Active) if (Normal) Red LED +.. Green LED 4 3°2„„_1()_„,,,,,,,„„ (Alarm/Active) �! 4 3 2 t (Normal) TBI IQI11111 1Il■ TBI NMI. ' { DATA IN(+) AsIIDATA OUT(+) ((DATA IN(+) Ajil ' DATA OUT(+)l DATA IN(-) , DATA OUT (-)} l DATA IN(-) • DATA OUT()li To Next Device From Signature Controller To Next Device From Signature Controller or Previous Device A or Previous Device Q SIGA-CT1,SIGA-CT1 HT SIGA-CT2 +I 1 ♦ ♦ Typical NO Initiating Device ♦ +I 1 I NOTES uuulCu:ted 1 uuulcusted 47KW EOL eh Input HCH 47KW EOL AMaximum 25 Ohm resistance per wire. A Maximum#12 AWG(2.5 mm2)wire;Minimum#18 AWG(0.75 mm2). AAA, ARefer to Signature controller installation sheet for wiring specifications. /`'\Maximum 10 Vdc @ 350 pA MCT2 The SIGA-UIO6R and the SIGH-UIO2R do not come with TBT 4. A Mani series motherboard 6 All wiring is supervised and power-limited. + ► Data In_ t Q 7 These modules will not support 2-wire smoke detectors. 1 : 5 Signature 1 1 It T814 No connections required for Data , Circuit I T07 MCR --- -- - - - Other modulese require - Data Out+ = connections. Warnings & Cautions - " , Imo VV 1 Green LED(Normal) il�`Ri This module will not operate without electrical power.As fires fre- Red LED(achvel csa T815 quently cause power interruption,we suggest you discuss further Nconnections jumper aa"'ngasafeguards with your local fireprotectionspecialist. requiredfor CT2. Compatibility SIGA-MCT2 The Signature Series modules are compatible only with EST's Signature Loop Controller. Page 3 of 4 85001-0241 Issue 8 . . ......, Specifications E0DWARDS Catalog Number SIGA-CT1HT 1 SIGA CT1 1 $ SIGA-MCT2 ualu . .. Description Single Input Module Dual Input Module Type Code 48(factory set)Four sub-types 49(factory set)Four sub-types Contact us... (personality codes)are available (personality codes)are available Email: edwards.fire@fs.utc.com Address Requirements Uses One Module Address Uses Two Module Addresses Web: www.est-fire.com Operating Current Standby=250pA; Standby=396pA; EST is an EDWARDS brand. Activated=400IA Activated=680pA 1016 Corporate Park Drive Operating Voltage 15.2 to 19.95 Vdc(19 Vdc nominal) Mebane,NC 27302 _ Construction High Impact Engineering Polymer In Canada,contact Chubb Edwards... Mounting North American 21/2 inch(64 mm)deep one-gang box- UIO2R/6R/6 Email: inquiries@chubbedwards.com es and 1'/2 inch (38 mm)deep 4 inch square boxes Motherboard Web: www.chubbedwards.com with one-gang covers and SIGA-MP mounting plates ©2013 UTC Fire&Security Americas Operating Environment 32°F to 158°F 32°F to 120°F(0°C to 49°C) Corporation,Inc.All rights reserved. (0°C to 70°C) Specifications subject to change Storage Environment -4°F to 140°F(-20°C to 60°C);Humidity:0 to 93%RH without notice.Edwards is part of UTC _ Climate,Controls&Security,a unit of LED Operation On-board Green LED-Flashes when polled;On-board Red LED- United Technologies Corporation. Flashes when in alarm/active. Both LEDs-Glow steady when in alarm(stand-alone) Compatibility Use with Signature Loop Controller Agency Listings UL,ULC,MEA,CSFM Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-CT1 Single Input Module— UL/ULC Listed 0.4(0.15) SIGA-CT1 HT Single Input Module High Temperature Operation UL/ULC Listed 0.4(0.15) SIGA-CT2 Dual Input Module— UL/ULC Listed 0.4(0.15) SIGA-MCT2 Dual Input Plug-in(UIO)Module —UL,ULC Listed 0.1 (0.05) Related Equipment 27193-11 Surface Mount Box-Red, 1-gang 1.0(0.6) 27193-16 Surface Mount Box-White, 1-gang 1.0(0.6) SIGA U102R Universal Input-Output Module Board w/Riser Inputs 0.32(0.15) —Two Module Positions SIGA U106R Universal Input-Output Module Board w/Riser Inputs 0.62(0.28) —Six Module Positions SIGA-U106 Universal Input-Output Module Board —Six Module Positions 0.56(0.25) MFC-A Multifunction Fire Cabinet— Red,supports Signature Module 7.0(3.1) Mounting Plates Transponder Mounting Bracket(allows for mounting SIGA-MB4 0.4(0.15) two 1-gang modules in a 2-gang box) SIGA-MP1 Signature Module Mounting Plate,1 footprint 1.5(0.70) SIGA-MP2 Signature Module Mounting Plate,1/2 footprint 0.5(0.23) SIGA-MP2L Signature Module Mounting Plate, 1/2 extended footprint 1.02(0.46) O S" Page 4 of 4 85001-0241 Issue 8 ). Intelligent Initiating Devices Intelligent Heat Detector ... SIGA-HRD 60' =• ,' '' f • S853 lam Overview Standard Features The SIGA-HRD is an intelligent fixed temperature/rate-of-rise fire Note:Some features described here may not be supported by detector. It monitors the temperature of the surrounding air and all control systems. Check your control panel's Installation and analyzes the data from the sensor to determine whether to initiate Operation Guide for details. an alarm.The rate-of-rise heat function quickly detects a fast, • Next Generation Heat Sensing Technology flaming fire.The fixed-temperature heat function detects fire when the air temperature near the detector exceeds the alarm point. • 15°F(9°C)per minute rate-of-rise alarm point The SIGA-HRD brings advanced sensing technology to a practi- • 135°F(57°C)fixed temperature alarm point cal design that increases efficiency,saves installation time,cuts • Uses existing wiring costs,and extends property protection capabilities.Continuous self-diagnostics ensures reliability over the long-haul,while the lat- • Automatic device mapping est thermister technology makes these detectors ideal whereever • Sensor Markings Provide Easy Testing Identification dependable heat detection is required. • Up To 250 Total Signature Devices Per Loop • Non-volatile memory • Electronic addressing • Bicolor(green/red)status LED • Standard, relay,fault isolator,and audible mounting bases • 50 foot(15.2 meter)spacing _ Page 1 of 4 E E85001-0647 Not to be useo for installation purposes.. Issue 1 Application Accessories The SIGA-HRD combination fixed temperature/rate-of-rise heat Detector mounting bases have wiring terminals that are acces- detector provides a 15°F(9°C)per minute rate-of-rise heat sible from the"room-side"after mounting the base to the electrical sensor for the detection of fast developing fires,as well as a box.The bases mount to North American 1-gang boxes and to 3/z inch or 4 inch octagon boxes, 11/2 inches(38 mm)deep.They 135°F(57°C)fixed temperature sensor for slow building-fires.The also mount to European BESA and 1-gang boxes with 60.3 mm heat sensor monitors the temperature of the air and determines fixing centers.The SIGA-SB4,SIGA-RB4,and SIGA-IB4 mount to whether an alarm should be initiated. North American 4 inch sq.electrical boxes in addition to the above boxes.They include the SIGA-TS4 Trim Skirt,which is used to cover the"mounting ears"on the base.The SIGA-AB4G mounts Compatibility to a 4 inch square box only. The SIGH-HRD detector is compatible only with the Signature Loop Controller. freal ` N. "_ 7Zio fit - atF SIGA-AB4G/T/LF SIGA-SB SIGA-IB SIGA-RB SIGA-LED Installation Audible Base Standard Base Isolator Base Relay Base Remote LED Signature Series detectors mount Remote LED SIGA-LED-The remote LED connects to the to North American 1-gang boxes, s. `+r 1* -''� SIGA-SB or SIGA-SB4 Standard Base only. It features a North 3-1/2 inch or 4 inch octagon ` American size 1-gang plastic faceplate with a white finish and red boxes,and to 4 inch square elec- Sett-locking tab alarm LED. trical boxes 1-1/2 inches(38 mm) 11 SIGA-TS4 Trim Skirt-Supplied with 4 inch bases,it can also deep.They mount to European be ordered separately to use with the other bases to help hide BESA and 1-gang boxes with 60.3voar surface imperfections not covered by the smaller bases. mm fixing centers.See mounting LED Indicator base installation and wiring for . Sounder Bases-Signature Series sounder bases are designed for use where localized or group alarm signaling is required. more information. • SIGA-AB4G bases provide sounder capability to Signature Series to heat and smoke detectors.They are not intended for use with combination carbon monoxide detectors in Fire- Sensing and reporting technology plus-CO mode. The microprocessor in each detector provides additional benefits- • SIGA-AB4GT bases provide sounder capability to Signature Self-diagnostics and History Log,Automatic Device Mapping,and Series smoke and heat detectors,as well as carbon monox- Fast, Stable Communication. ide detectors when used with a SIGA-TCDR Temporal Pattern Generator. Self-diagnostics and History Log- Each Signature Series • SIGA-AB4G-LF bases provide 520 Hz low frequency detector constantly runs self-checks to provide important mainte- sounder capability to Signature Series smoke and heat detec- nance information.The results of the self-check are automatically tors,as well as carbon monoxide detectors when used with a updated and permanently stored in the detector's non-volatile SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF memory. is suitable for applications requiring low frequency audible Automatic Device Mapping-The loop controller learns where tones. each device's serial number address is installed relative to other devices on the circuit.The mapping feature provides supervision of each device's installed location to prevent a detector from being Warnings & Cautions reinstalled(after cleaning etc.)in a different location from where it • This detector does not operate without electrical power.As was originally. fires frequently cause power interruption,discuss further safe- Fast Stable Communication-On-board intelligence means less guards with the local fire protection specialist. information needs to be sent between the detector and the loop • This detector does not sense fires in areas where heat cannot controller.Other than regular supervisory polling response,the reach the detector. Heat from fires in walls, roofs,or on the detector only needs to communicate with the loop controller when opposite side of closed doors may not reach the detector. it has something new to report. • This heat detector by itself does not provide life safety protec- tion Use this detector with ionization and/or photoelectric smoke detectors. • This detector does not detect oxygen levels,smoke,toxic gases,or flames. Use this device as part of a broad-based life safety program which includes a variety of information sources pertaining to heat and smoke levels,extinguishment systems,visual and audible devices,and other safety mea- sures. • Independent studies indicate that heat detectors should only be used when property protection alone is involved. Never rely on heat detectors as the sole means of fire protection. Page 2 of 4 DATA SHEET E85001-0647 est to be used for 3nsta!!atlon purpose _ Issue 1 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2),#16 Relay Detector Base,SIGA-RB,SIGA-RB4 Normally-Normally- (1.0mm2), #14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. This base includes a relay. Nor- Common aosed Open Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred mally Open or Normally Closed for ease of installation. operation is selected during in- stallation.The dry contact is rated Standard Detector Base,SIGA-SB,SIGA-SB4 for 1 amp(pilot duty) 30 Vdc. c n The relay's position is supervised This is the basic mounting base Remote LED to avoid accidentally jarring it out1111P ',Q�'i� for EDWARDS Signature Series 1 Max resistance of position.The SIGA-RB can be DATA'"`) zl� DATAOUrc-> detectors.The SIGA-LED Re- .n. per wire operated as a control relay if pro- _ must not exceed DATA OUT O.) mote LED is supported by this 10 Ohms grammed to do so at the control DATA INC.) To NextDevice From Signature Controller Base. 4,,,,,-1 \ panel.The relay base does not or Previous DeviceTerm Desch hon Tenn Description _ su ort the SIGA-LED Remote p1 Not Used t'' (' pp 1 Normally Open 2 DATA IN/OUT(+) ^-:,,^ LED. CONTACT RATING 2 DATA IN/OUT(+) � 3 Not Used •8 1.0 Amp @ 30 VDC 3 Common 4 DATA IN(-) \ %27. (Pilot Duty) 4 DATA IN(-) 4 Remote LED(-) DATA INN Zi / DATA OUT(-) 5 Not Used 5 Remote LED(+) 6 Normally-Closed 6 Not Used 7 DATA OUT(-) 7 DATA OUT(-) DATA IN 1+1 DATA OUT 1+) From Signature Controller To Next Device or Previous Device Audible Sounder Bases,Fire Mode Isolator Detector Base,SIGA-IB,SIGA-164 AB4GT,AB4G,AB4G-LF sounder bases This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. SIGA-AB4GT, o o SIGH-AB4G-LF: The isolator operates as follows: SIGH-AB4G, ®Jumper cuts® Output Mode SIGA-AB4G-LF: Default=Fire •-a short on the line causes all iso- O 6 Volume SettingDefault=HCut/remove jumper for T lators to open within 23 msec !' oe 0 CuUremoveigh Fire plus CO -at 10 msec intervals, Po�a . t!J jumper for SIGA-AB4G: low dB ® ® Tone Setting beginning on one side A ` Default=Temporal of the Class A DATA IN(-) \ ( 1z1 DATA-DATA-DATA. I DATA OUT(-) SIG. SIG- OUT w IN/OUT Cut/remove jumper for circuit nearest the loop 111 @ 1 U 111 Steady controller,the isolators +--+- +--y--+ o SIGA-AB4GT: DATA OUT(+) 1..11. 111 close to provide the DATA IN(+) 11 11 11 Not Used From Signature Controller To Next Device I C+4I na I gig le I 4I0 next isolator down the 111111 lor Previous Device line with power Term Description 1 Not Used 24 Vdc in -when the isolator next 2 DATA IN/OUT(+) From power supply + 4 Not Used ■-M' - 24 Vdc out + To next base or EOL rela to the short closes,it reopens within 10 3 DATA IN(-) or previous base .,Iy msec. 5 Not Used - 6 DATA OUT(-) Data in _ Data out The process repeats beginning on the 7 Not Used From Signature Controller to next Signature device other side of the loop controller. or previous device + + Page 3 of 4 DATA SHEET E85001-0647 Not to be used for Installation purposes. Issue 1 Dimensions 14)44.. q ,FF S/FFT' S iNC.4DEN 7 MANAC;EMF".T Contact us... d toM oo I � Email: edwards.fire@fs.utc.com Web: Edwards-fire.com / 5 ��..;.�.+� "+r✓ MS EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane,NC 27302 2` ' ©2016 United Technologies Corporation. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 32 pA Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Rate-of-rise rating 15°F/min(8°C/min) Fixed temperature rating 135°F(57.2°C).Actual alarm point 129 to 141°F(53.9 to 60.6°C). Maximum spacing 50 ft.(15.2 m)centers Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 100°F(0 to 38°C),0 to 93%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Agency Listings CAN/ULC-S530,UL 521 Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-HRD Intelligent fixed temperature/Rate-of-rise heat detector 0.4(0.16) Compatible Bases SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2(.09) S1GA 1B __ Detector Mounting Rase_w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) SIGA-AB4G Audible(Sounder)Base for Fire Detectors 0.3(0.15) SIGA-AB4G-LF Low Frequency Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool 0 Page 4 of 4 E85001-0647 r m"."_s,r;nurpn.;. Issue 1 0- Intelligent Initiating Devices WARDS United Technologies Intelligentm S oke Detector wow oillt SIGA-PD t - -�.. 4 l -.r• S853 65) Overview Standard Features The Signature Series SIGA-PD optical smoke detector brings ad- Note:Some features described here may not be supported by vanced sensing technology to a practical design that increases ef- all control systems. Check your control panel's Installation and ficiency,saves installation time,cuts costs,and extends life safety Operation Guide for details. and property protection capabilities. Continuous self-diagnostics • Next Generation Optical Smoke Sensing Technology ensure reliability over the long-haul,while environmental compen- sation helps reduce maintenance costs. • Wide 0.53 to 3.94%/ft.(1.7 to 12.35%/m)smoke obscuration Like all Signature Series detectors,the SIGA-PD is an intelligent • Uses Existing Wiring device that gathers analog information from its optical sensor, • Automatic Device Mapping converting this data into digital signals.To make an alarm decision, the detector's on-board microprocessor measures and analyzes • Up To 250 Total Signature Addresses Per Loop sensor readings and compares this information to historical data. • Two Levels of Environmental Compensation Digital filters remove signal patterns that are not typical of fires, thus virtually eliminating unwanted alarms. • Two Levels of Dirty Detector Warning • Twenty Pre-Alarm Settings • Five Sensitivity Settings • Non-Volatile Memory • Electronic Addressing • Identification of Dirty or Defective Detectors • Automatic Day/Night Sensitivity Adjustment • Bicolor(Green/Red)Status Led • Standard, Relay, Fault Isolator,and Audible Mounting Bases • Sensor Markings Provide Easy Testing Identification Page 1 of 4 E85001-0646 Issue 1 Application Testing & Maintenance The SIGA-PD detects extremely small particles of combustion and Each detector automatically identifies when it is dirty or defective triggers an alarm at the first sign of smoke.Thanks to its high- and causes a"dirty detector"message.The detector's sensitiv- performance forward-scattering reflective response technology, ity measurement can also be transmitted to the loop controller.A the photoelectric smoke sensor responds quickly and reliably to sensitivity report may be printed to satisfy NFPA sensitivity mea- a wide range of fire types,especially slow burning fires fuelled by surements,which must be conducted at the end of the first year combustibles typically found in modern multi-use buildings. and every two years thereafter. The user-friendly maintenance program shows the current state Compatibility of each detector and other pertinent messages.Single detectors may be turned off temporarily from the control panel.Availability of The SIGA-PD detector is compatible only with the Signature Loop maintenance features is dependent on the fire alarm system used. Controller. Accessories InstallationDetector mounting bases have wiring terminals that are acces- sible from the"room-side"after mounting the base to the electrical Signature Series detectors mount to North American 1-gang boxes, " " > box.The bases mount to North American 1-gang boxes and to 3-1/2 inch or 4 inch octagon , ` 3' inch or 4 inch octagon boxes, 11 inches(38 mm)deep.They Self-locking tab also mount to European BESA and 1-gang boxes with 60.3 mm boxes,and to 4 inch square elec- fixing centers.The SIGA-SB4,SIGA-RB4,and SIGA-IB4 mount to trical boxes 1-1/2 inches(38 mm) r.r,w " North American 4 inch sq.electrical boxes in addition to the above deep.They mount to European boxes.They include the SIGA-TS4 Trim Skirt,which is used to BESA and 1-gang boxes with 60.3 cover the"mounting ears"on the base.The SIGA-AB4G mounts mm fixing centers.See mounting - LED indicator to a 4 inch square box only. base installation and wiring for more information. " *4'4) Sensing and reporting technology SIGH-AB4G/T/LF SIGH-SB SIGH-IB SIGH-RB SIGH-LED The microprocessor in each detector provides additional benefits Audible Base Standard Base Isolator Base Relay Base Remote LED Self-diagnostics and History Log,Automatic Device Mapping,and Remote LED SIGA-LED-The remote LED connects to the Fast, Stable Communication. SIGA-SB or SIGA-SB4 Standard Base only. It features a North Self-diagnostics and History Log Each Signature Series American size 1-gang plastic faceplate with a white finish and red alarm LED. detector constantly runs self-checks to provide important mainte- nance information.The results of the self-check are automatically SIGA-TS4 Trim Skirt Supplied with 4 inch bases, it can also updated and permanently stored in the detector's non-volatile be ordered separately to use with the other bases to help hide memory surface imperfections not covered by the smaller bases. Sounder Bases-Signature Series sounder bases are designed Automatic Device Mapping-The loop controller learns where for use where localized or group alarm signaling is required. each device's serial number address is installed relative to other • SIGA-AB4G bases provide sounder capability to Signature devices on the circuit.The mapping feature provides supervision Series to heat and smoke detectors.They are not intended of each device's installed location to prevent a detector from being for use with combination carbon monoxide detectors in Fire- reinstalled(after cleaning etc.)in a different location from where it plus-CO mode. was originally. • SIGA-AB4GT bases provide sounder capability to Signature Fast Stable Communication-On-board intelligence means less Series smoke and heat detectors,as well as carbon monox- information needs to be sent between the detector and the loop ide detectors when used with a SIGA-TCDR Temporal Pattern controller.Other than regular supervisory polling response,the Generator. detector only needs to communicate with the loop controller when • SIGA-AB4G-LF bases provide 520 Hz low frequency it has something new to report. sounder capability to Signature Series smoke and heat detec- tors,as well as carbon monoxide detectors when used with a v_ SIGA-TCDR Temporal Pattern Generator.The SIGA-AB4G-LF is suitable for applications requiring low frequency audible tones. Page 2 of 4 E85001-0646 .,rnv Sia. issue 1 Typical Wiring The detector mounting bases accept#18 AWG(0.75mm2), #16 Audible Sounder Bases, Fire Mode (1.0mm2), #14 AWG(1.5mm2),and#12 AWG(2.5mm2)wire sizes. AB4GT,AB4G,AB4G-LF sounder bases Sizes#16 AWG(1.0mm2)and#18 AWG(0.75mm2)are preferred for ease of installation. Standard Detector Base,SIGA-SB,SIGA-SB4 SIGA-AB4GT, O O SIGA-AB4G-LF: SIGA-AB4G, ®jumper cuts® Output Mode SIGA-AB4G-LF: Default=Fire This is the basic mounting base Remote LED Volume Setting Cut/remove jumper for for EDWARDS Signature Series I Max resistance Default=High Fire plus CO detectors.The SIGA-LED Re- 4•• per wire Cut/remove mote LED is supported by this + mu 1t 0 Ohms lnot exceedoow dB for ® ® Tone Sett ng Base. DATA-DATA-DATA+ Default=Temporal SIG. SIO- our IN IN/OUT Cut/remove jumper for Term Description it'll....,\, _ _ _ 1 P 1 Not Used T T Steady 2 DATA IN/OUT(+) "II" �II^�II^!1�^�T�^�j� 0 3 Not Used ,lb<,` t .1,1,,...,1,---,i 1r SIGA-AB4GT: 4 DATA IN(-) G +� +� 1I\I�-T�I�+0I Not Used 4 Remote LED(-) DATA IN(-1 1 , DATA OUT 1-1 I 5 Remote LED(+) - 111111 6 Not Used 7 DATA OUT(-) DATA IN(+1 DATA OUT 1+) 24 Vdc in From Signature Controller To Next Device From power supply ■-■' - 24 Vdc out or Previous Device or previous base + .,I + To next base or EOL relay Data in . Data out Isolator Detector Base,SIGA-IB,SIGA-1B4 From Signature Controller to next Signature device or previous device + + This base includes a built-in line fault isolator for use on Class A circuits.A detector must be installed for it to operate.The isolator base does not support the SIGA-LED Remote LED. Warnings & Cautions The isolator operates as follows: -a short on the line causes all iso- °; • This detector does not operate without electrical power.As .., r� o' 0 fires frequently cause power interruption, discuss further lators to open within 23 msec o,, o/ 11- safeguards with the local fire protection specialist. -at 10 msec intervals, beginning on one side • This detector does not sense fires in areas where smoke of the Class A DATA IN(-) \ (j'_a i I DATA OUT(-) cannot reach the detector. Smoke from fires in walls, roofs, circuit nearest the loop controller,the isolators or on the opposite side of closed doors may not reach the close to provide the DATA IN(+) DATA OUT(+) detector. next isolator down the From Signature Controller To Next Device or Previous Device • Photoelectric detectors have a wide range of fire sensing line with power Term Description capabilities and are best suited for detecting slow,smolder- 1 Not Used -when the isolator next 2 DATA IN/OUT(+) ing fires. to the short closes,it reopens within 10 3 DATA IN(-) 4 Not Used • In Canada, install according to CAN/ULC-S524 Standard for msec. 5 Not Used DATA OUT(-) the Installation of Fire Alarm Systems, CSA C22.1 Canadian The process repeats beginning on the 7 Not Used Electrical Code,and the local authority having jurisdiction. other side of the loop controller. Relay Detector Base,SIGA-RB,SIGA-RB4 Normally-Nomay- This base includes a relay. Nor- Common Closed Open mally Open or Normally Closed operation is selected during in- stallation.The dry contact is rated for 1 amp(pilot duty)@ 30 Vdc. ,, iii The relay's position is supervised to avoid accidentally jarring it out •� __ _ _, _ of position.The SIGA-RB can be DATA IN6.) \ u / DATAW(-> operated as a control relay if pro- grammed to do so at the control DATA 1.4(+) DATA OUT(4) To Next Device Slonalurer panel.The relay base does not Fr aPrevious D °I� support the SIGA-LED Remote Term Description 1 Normally Open LED. CONTACT RATING 2 DATA IN/OUT(+) 1.0 Amp @ 30 VDC 3 Common (Pilot Duty) 4 DATA IN(-) 5 Not Used 6 Normally-Closed 7 DATA OUT(-) Page 3 of 4 E85001-0646 3501 F4: 110.,l 0U 11r ,r 1,{;2: C } 1)10001,0 Issue 1 Dimensions actwARDs LIFE SAFETY&INCIDENT MANAGEMENT i ` � 7L ' Contact us... b� } dlonoa � ( ' Email: edwards.fire@fs.utc.comtittJJI� A / Web: Edwards-fire.com , EDWARDS is a UTC brand. 1016 Corporate Park Drive Mebane,NC 27302 ©2016 United Technologies Corporation. All rights reserved. Specifications Operating voltage 15.20 to 19.95 VDC Normal operating current 32 pA Alarm current 32 pA Smoke Sensitivity Range UL/ULC:0.53 to 3.94%/ft.(1.7 to 12.35%/m)obscuration Vibration level 10 to 35 Hz,with an amplitude of 0.01 in. Air velocity 0 to 4,000 ft./min(0 to 20 m/s) Wall mounting 12 in.(305 mm)max.from ceiling Compatible bases See Ordering Information Compatible detector testers Testifire 1000,Testifire 2000 Operating environment 32 to 120°F(0 to 49°C),0 to 93%RH,noncondensing Construction High Impact Engineering Polymer,White Storage temperature -4 to 140°F(-20 to 60°C) Environmental compensation Automatic Agency Listings CAN/ULC-S529,UL 268,UL 268A Ordering Information Catalog Description Ship Wt. Number lbs(kg) SIGA-PD Intelligent Optical Smoke Detector 0.4(0.16) Accessories SIGA-SB Detector Mounting Base-Standard SIGA-SB4 4-inch Detector Mounting Base c/w Trim Skirt SIGA-RB Detector Mounting Base w/Relay SIGA-RB4 4-inch Detector Mounting Base w/Relay, c/w Trim Skirt 0.2(.09) SIGA-IB Detector Mounting Base w/Fault Isolator SIGA-IB4 4-inch Detector Mounting Base w/Fault Isolator,c/w Trim Skirt SIGA-LED Remote Alarm LED(not for EN54 applications) Audible(Sounder)Base for Fire Detectors 0.3(0.15) SIGA-AB4G-LF Low Frequency Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-AB4GT Audible(Sounder)Base for CO and Fire Detectors 0.3(0.15) SIGA-TS4 Trim Skirt(supplied with 4-inch bases) 0.1 (0.04) SIGA-TS Trim Skirt-(optional for non 4-inch bases) 0.1 (0.04) SIGA-DMP Detector Mounting Plate 3.0(1.4) SIGA-RTA Detector Removal Tool SIGA-VA Detector Cleaning Tool Page 4 of 4 E85001-0646 Net to �e : . Issue 1 Intelligent Initiating EST Life Safety & Communications Intelligent Duct Smoke Detector - ., SIGH—SD ..e: .x ® O MEA 324022357 5853 Overview Standard Features The Edwards SuperDuct Signature Series smoke detector is the • Less than 2"deep for easy installation and applications where most advanced and most reliable device in its class. Designed for space is tight easy installation and superb reliability,SuperDuct represents the -4°F to 158°F(20°C to 70°C) operating range with 100 ft/min. perfect balance of practical design and advanced technology. to 4,000 ft/min air velocity rating assures reliability under harsh SuperDuct detectors feature a unique design that speeds instal- environmental conditions lation and simplifies maintenance. Removable dust filters,confor- • Status LEDs remain visible through clear assembly cover mally coated circuit boards,and optional water-resistant gaskets keep contaminants away from components,ensuring years of • Cover monitor switch for added security trouble-free service.When cleaning is required,the assemblies • Standard sampling tube spacing for easy drop-in migration come apart easily and snap back together in seconds. from other detectors A Signature Series photoelectric sensor is incorporated into • Sampling tube can be installed with or without the cover in the design of each SIGA-SD duct smoke detector.This sensor place and can be rotated in 45-degree increments to ensure inherits the power and benefits of this exceptional line of intelligent proper alignment with duct airflow devices. • 15.2 to 19.95 Vdc operation Signature Series sensors gather analog information from their • smoke sensing elements and convert it into digital signals.The Magnet activated test switch sensor measures and analyses these signals and compares the • One Form C auxiliary alarm relay for controlling ancillary equip- information to historical readings and time patterns to make an ment(e.g., HVAC controls) alarm decision. Digital filters remove signal patterns that are not y typical of fires,which virtually eliminates unwanted alarms. • No special tools required for easy access to field connections • Signature Series intelligence WARNING: Duct detectors have specific limitations. Duct detectors are not a • Environmental compensation with differential sensing for reli- substitute for an open area smoke detector.Duct detectors are not a substitute able,stable,and drift-free sensitivity for early warning detection or a replacement for a building's regular fire detection system.Smoke detectors are not designed to detect toxic gases which can build up • Wide 0.79%to 2.46%obscuration/ft.smoke sensitivity to hazardous levels in some fires.These devices will not operate without electrical power.As fires frequently cause power interruptions,Edwards suggests you discuss • Identification of dirty or defective detectors further safeguards with your local fire protection specialist. Page 1 of 4 85001-0584 Issue 6 Application The sampling tube may be installed from either the duct side of SuperDuct detectors are ideally suited to duct smoke detection the assembly or from inside the sensor compartment,as preferred by the installer.(The exhaust tube must be installed from the duct applications where early indication of combustion is required within side.)Sampling tubes may be rotated in 45-degree increments so the confined space of ventilation ductwork. Its primary purpose that air-holes can be aligned to allow the unit to be mounted at is to provide early warning of an impending fire and to prevent virtually any angle relative to the air flow. smoke from circulating throughout the building. It is typically used to detect smoke in the supply side of the HVAC system but can In installations where the duct smoke detector's controls and indica- provide supervision of the return side as well. tors are hidden from view,a remote test station or an LED indicator can be connected to the detector to provide these functions. Protected premises Remote Remote Test Stations Alarm relay test output Station Labor-saving Remote Test/Reset stations provide 1 alarm testing from the convenience of a remote location.Tests can be performed quickly and safely Duct smoke < Returni. —without having to climb to the roof. Magnetically- - detector air wow.. , operated and key-operated one-gang models are HVAC 1 unit _ I ' available.Signature SuperDuct detectors are also � _Duct smoke_ supply compatible with SIGA-LED remote alarm LED. — I detector air T Air velocity in the duct as low as 100 ft/min.maintains adequate Alarm relay air flow into the sensor smoke chamber through air holes in the air output Remote sampling tube and discharges through the exhaust tube.Su- test FACP station perDuct air sampling tubes must be installed with the inlet holes facing the airstream. Sampling tubes may be rotated in 45-degree increments so that air-holes can be aligned to allow the unit to be SuperDuct detectors continually sample air flow in the HVAC duct mounted in virtually any angle relative to the airflow. and initiate an alarm condition whenever smoke is detected. An SuperDuct sensors are engineered to operate optimally under the alarm is activated when the quantity(percent obscuration)of harsh environmental conditions frequently found in HVAC duc- combustion products in that air sample exceeds the detector's twork. Nonetheless, before installing the detector,test the duct sensitivity setting. air velocity,temperature,and humidity to verify that it is within the operating range of the SuperDuct detector. Consult the SuperDuct Signature Series Intelligence installation sheet for details. Like all Signature detectors,the SIGA-SD features electronic addressing and issues a dirty sensor warning when it reaches its Dimensions preset limit.The dirty sensor warning indicates the sensor is op- erating within its specified limits but is in need of servicing.When 8.70 in(22.1 cm) . 8.15 in(20.7 cm) the detector's ability to compensate for environmental changes 7.75 in(19.7 cm) has reached its limit,the duct smoke detector signals a trouble 3.08 in(7.82 cm) 4.56:1)-.' condition. The SIGA-SD also uses differential sensing to prevent gradualr, r, �� environmental changes from triggering unwanted alarms.A rapid change in environmental conditions,such as smoke from a fire, causes the detector to signal an alarm state, but dust and debris accumulated over time does not change alarm sensitivity. i i .. _ 1 i Each Signature Series SuperDuct detector contains a microproc- 1 essor that performs comprehensive self-diagnostics and stores i the results in nonvolatile memory.Stored results include details 2.28 In such as hours of operation, last maintenance date,and number (5.78 cm) of alarms and troubles.This information can be retrieved and �' reviewed when desired. -- �)j Detector Configuration ; ; 5.45i^ The detector assembly cover provides easy access to the smoke <4-1 "3.84 n , sensor,its wiring connections,sample and exhaust tubes,and the ; smoke chamber itself. 47.0. 0000 0 0 0 Air enters the detector's sensing chamber through a sampling ; - - ' i1 r. , tube(ordered separately)that extends into the duct and is directed { back into the ventilation system through an exhaust tube(in- ; I1.90 in , (4.83 cm) cluded).The difference in air pressure between the two tubes pulls i �r1 I the sampled air through the sensing chamber.When a sufficient , 4 ' i l amount of smoke is detected in the sensing chamber,the detector ; ; initiates an alarm. i i i1.38 in i 5.40 in (3.51 crn) - (13.72 cm) Page 2 of 4 DATA 85001-0584 Not to be used ter Issue 6 Assembly High-humidity environments Sampling tube Detector socket �� Use the SD-PH Protective Housing when installing SuperDuct Exhaust tube ,t,:"-----"\--- _\� detectors in high-humidity environments.The SD-PH is a weather- socket �,• ized housing that prevents condensation on the device by insulat- ing the detectors and providing circulated air from the monitored rt 111HVAC duct.The SD-PH also adds a layer of protection against h sical dama a to the unit. , G p Y 9 Exhaust tube Thin x gasket ,� c 4 Thick / gasket (I�� Coupling `k 01 0 1f SD-PH '�� Duct Detector Sampling tube Protective (ordered separately) Housing 1k14; - ' ''. Plug 1,� ll Mounting l; '� Rear View 4. 111111 -•-• HVAC duct Airflow ' 1) /1 6L Hinged U( N Detector Cover `� ® Housing `� ` ` ` � ,� air tube \ � �,, \irf,-.\ Housing Detector N j `�' `/ ) air tube conduit holes Sampling Ir � - tube Oil* [i/,I The SD-PH is easy to install and service.The hinged and transpar- " ., ent cover provides ready access to the detector,while keeping its status indicators visible at all times. #10 sheet metal screw(2X) Note: The SD-PH Protective Housing is weatherized against out- door air, but it is not intended for direct outdoor exposure. Wiring Auxiliary equipment SIGA-LED[1] MMIIM [1] No more than one remote test station O 1 ®®® or LED indicator can be connected to °` f 1 -- -- �� the detector at the same time.Wiring 01 17 16 15 is unsupervised.Maximum wire Alarm resistance is 10 ohms per wire. ® SD-TRK `1 FJ Test or SD-TRM[1] 0 cr-i____ irr.a.. -- I [ Data Out(-) Data Out(+) Data In(+) Data In(-)__I �I®®®®®®®® Iri r7 r, r, r7 1-7 ri c, 0 0 o oo 14 13 12 11 10 9 8 7 1 Power indicator Alarm indicator Page 3 of 4 85001-0584 Issue 6 Specifications, detector Specifications, test stations El:" 1 ■�\ '!."� Remote Test/Reset Stations provide alarm test,trouble is a Dimensions 8.70 x 5.45 x 1.90 inches (221 x 138 x 48 mm) indication,and reset capability from a remote loca- 0 unHaAteep��gbs -- tion.They include a one-gang plate,momentary SPST Wire size 14 to 22 AWG switch,red alarm LED,and terminal block.Magnetically- Contact us... I< Detection Photoelectric operated models(TRM)or key-operated models(TRK) method (light scattering principle) Email: edwards.fire@fs.utc.com -� Compatible North American 1 gang box 100 to 4,000 ft/min andStandard 4 in square box, Web: www.est-fire.com Air velocity electrical ratingmeets the required minimum 1-1/2 inches deep,with EST is an EDWARDS brand. air pressure differential boxes 1-gang cover 1016 Corporate Park Drive Air pressure 0.005 to 1.00 inches of _LED indicators Alarm(red) Mebane,NC 27302 differential water LED type Clear lens In Canada,contact Chubb Edwards... 0.79 to 2.46%/ft Sensitivity Wire size 14 to 22 AWG Email: inquiries@chubbedwards.com obscuration Resistance per Web: www.chubbedwards.com Alarm test 10 Ohms,max. response time 5 seconds wire ©2013 UTC Fire&Security Americas -- Current Corporation,Inc.All rights reserved. LED indicators Alarm(red),Power(green) requirements See controller specifications Specifications subject to change Unsupervised and power- LED circuit Voltage:3 Vdc,max. without notice.Edwards is part of UTC limited Climate,Controls&Security,a unit of ratings Current:30 mA,max. United Technologies Corporation. Common Quantity:1 Switch ratings Voltage:125 Vdc,max. alarm relay Type:Form C Ratings:2.0 A at 30 Vdc (SD TRK) Current:4 A,max. (resistive) Switch ratings Voltage:200 Vdc,max. Operating (SD-TRM) Current:0.5 A,max. 15.2 to 19.95 Vdc SuperDuct conventional voltage Compatible two-wire and Signature duct Operating Standby:45 pA Alarm:45 detectors smoke detectors current pA Inrush: 1 mA Standalone -4°F to 158°F(-20°C to alarm: 18 mA Operating ° Temperature(UL):-4 to 158 environment 70°C)Humidity:930/0 RH, °F(-29 to 70°C). _ noncondensing Operating Temperature(ULC):-4 to Storage -4 to 140°F(-20 to 60°C) environment 120°F(-29 to 49°C) temperature Relative humidity: 10 to Agency listings UL,ULC,MEA,CSFM 93%,noncondensing Agency UL,ULC,CSFM,FM,MEA listings Ordering Information Catalog Number Description Ship Wt.,lb.(kg) SIGA-SD Intelligent SuperDuct Detector 2.4(1.1) Accessories SD-T8 8-inch sampling tube 0.5(0.2) SD-T18 18-inch sampling tube 1.5(0.7) - - - SD-T24 244nch sampling tube 2.7(1.2) SD-T36 36-inch sampling tube 3.0(1.4) SD-T42 42-inch sampling tube 3.5(1.6) SD-T60 60-inch sampling tube 5.8(2.6) SD-T78 78-inch sampling tube 7.5(3.4) SD-T120 120-inch sampling tube 11.5(5.2) SD-PH Protective housing for high humidity environments 5.5(2.5) SIGA-LED Remote alarm LED 1.0(0.5) SD-TRM Remote test station,magnetic 1.0(0.5) SD-TRK Remote test station,keyed 1.0(0.5) SD-VTK Air velocity test kit(stoppers only,etc) 1.0(0.5) SD-GSK Cover gasket kit 0.5(0.2) SD-MAG Test magnet kit _ 0.5(0.2) SIGA-SDPCB Replacement PCB/Signature sensor kit 1.0(0.5) 0 Page 4 of 4 85001-0584 w Issue 6 V) LU U_ LU 0 z 0 F- Q U LI I- 0 z Strobes, Horns, Bells,Chimes EST Life Safety & Communications (74 ®(....iii, ?". 7125-1657: C �� `! FCl sz18, "••�;�.�� S5369, ,, ....-...... .. -..- Field Configurable .---y-...=.. �E 52970 ` MEA Zzx • FM Horns and iti: ,,,,-,..„, 0, , „ „.„01 0- , Strobes 75 , , r Genesis Series ECS/MNS appliances available £` � '. S with clear or amber lenses. =; - , A' A ', �� E E �, %;_ ,\ ALERT T r - Overview Standard Features The Genesis line of fire alarm and mass notification/emergency • Unique low-profile design communications(ECS/MNS)signals are among the smallest, - The most compact UL-1971/ULC-S526 listed strobe available most compact audible-visible life safety signaling devices in the - Ultra-slim-protrudes less than one inch world.About the size of a deck of playing cards,these devices are - Attractive appearance designed to blend with any decor. - No visible mounting screws Thanks to patented breakthrough technology, Edwards Gen- • Four field-configurable options in one device esis strobes do not require bulky specular reflectors and lenses. - Select 15,30, 75,or 110 cd strobe output Instead,an exclusive cavity design conditions light to produce - Select high(default)or low dB horn output a highly controlled distribution pattern. Significant development - Select temporal(default)or steady horn output efforts employing this new technology have given rise to a new - Select public mode flash rate(default)or private mode benchmark in strobe performance-FullLight technology. temporal flash FullLight strobe technology produces a smooth light distribution • Fixed 15/75 cd model available pattern without the spikes and voids characteristic of specular re- • ECS/MNS models available flectors.This ensures the entire coverage area receives consistent illumination from the strobe flash.As a result,Genesis strobes with • Easy to install FullLight technology go well beyond the UL-1971 and ULC-S526 - Fits standard 1-gang electrical boxes -no trim plate needed light distribution requirements. - Optional trim plate accommodates oversized openings - Pre-assembled with captive hardware Genesis strobes and horn-strobes offer selectable candela output - #12 AWG terminals-ideal for long runs or existing wiring --- by means of a conveniently-located switch on the side of the device. Models are also available that offer fixed 15/75 cd output. Unparalleled performance • The candela output setting remains clearly visible even after final - Industry's most even light distribution installation,yet it stays locked in place to prevent unauthorized - Meets tough synchronizing standards for strobes tampering. - Single microprocessor controls both horn and strobe - Independent horn control over a single pair of wires Genesis ECS/MNS appliances offer emergency signaling with - Highly regulated in-rush current clear or amber lenses and with optional ALERT housing labels. - Multiple frequency tone improves sound penetration They are ideal for applications that require differentiation between - Field-programmable temporal strobe output option fire alarm and mass notification alerts. Page 1 of 6 85001-0573 Issue 11.1 Application Installation Genesis strobes are UL 1971-listed for use indoors as wall-mount- Genesis horns and strobes mount to any standard one-gang sur- ed public-mode notification appliances for the hearing impaired. face or flush electrical box. Matching optional trim plates are used Prevailing codes require strobes to be used where ambient noise to cover oversized openings and can accommodate one-gang, conditions exceed 105 dBA(87dBA in Canada),where occupants two-gang,four-inch square,or octagonal boxes,and European use hearing protection,and in areas of public accommodation 100 mm square. as defined in the Americans with Disabilities Act(see application All Genesis signals come pre assembled notes—USA). fi with captive mounting screws for easy in- Combination horn-strobe signals must be installed in accordance �' F stallation.Two tabs at the top of the signal with guidelines established for strobe devices.Consult with your I } I unlock the cover to reveal the mounting Authority Having Jurisdiction for details. R R hardware.The shallow depth of Genesis All Genesis strobes exceed UL synchronization requirements E E devices leaves ample room behind the signal for extra wiring.Once installed with (within 10 milliseconds over a two-hour period)when used with a ...,,. the cover in place, no mounting screws synchronization source. Synchronization is important in order to - -- ill are visible. avoid epileptic sensitivity. WARNING:These devices wit not operate without electrical power.As fires frequently cause power interruptions, further safeguards such asGenesis Horn/Strobe Field Configuration backup power supplies may be required. with optional trim plate Temporal horn and horn-strobe models are factory set to sound in a three-pulse temporal pattern. Units may be con- figured for use with coded systems by cutting a jumper on the Horns circuit board.This results in a steady output that can be turned Genesis horn output reaches as high as 99 dB and features a on and off(coded)as the system applies and removes power to unique multiple frequency tone that results in excellent sound the signal circuit.A Genesis Signal Master is required when horn- penetration and an unmistakable warning of danger. Horns may be strobe models are configured for coded systems.Non-temporal, configured for either coded or non-coded signal circuits.They can horn-only models sound a steady tone. also be set for low dB output with a jumper cut that reduces horn Genesis clear strobes and horn-strobes are shipped from the fac- output by about 5 dB.Horn-only models may be ceiling-mounted tory ready for use as UL 1971 compliant signals for public mode or wall-mounted. operation.These signals may be configured for temporal flash by The suggested sound pressure level for each signaling zone used with cutting a jumper on the circuit board.This battery-saving feature is alarm signals is at least 15 dB above the average ambient sound level, intended for private mode signaling only. or 5 dB above the maximum sound level having a duration of at least Genesis clear strobes and horn-strobes may be set for 15,30,75, 60 seconds,whichever is greater,measured 5 feet(1.5 m)above the or 110 candela output.The output setting is changed by simply floor.The average ambient sound level is,A-weighted sound pressure opening the device and sliding the switch to the desired setting. measured over a 24-hour period. The device does not have to be removed to change the output Doubling the distance from the signal to the ear will theoretically result setting.The setting remains visible through a small window on the in a 6 dB reduction of the received sound pressure level.The actual side of the device after the cover is closed. effect depends on the acoustic properties of materials in the space. Horns and horn-strobes are factory set for high dB output. A 3 dBA difference represents a barely noticeable change in volume. Low dB output may be selected by cutting a jumper on the circuit board.This reduces the output by about 5 dB. ECS/MNS Applications Genesis ECS/MNS strobe appliances bring the same high- performance fire alarm features and unobtrusive design to mass notification applications.Available with amber lenses and optional Wiring ALERT housing labels,they are ideal for applications that require Field wiring terminals accommodate#18 to#12 AWG(0.75 mm2 differentiation between fire alarm and mass notification alerts. to 2.5 mm2)wiring. Horns,strobes,and combination horn-strobes are interconnected with a single pair of wires as shown below. 0 To next appliance, Polarity shown in �� end of-line alarm condition ___________________________p©' or rreturn to cont411.6, JJ equipment ONote:Strobes must have continuous voltage. Page 2 of 6 85001-0573 Issue 11.1 Current Draw Strobes, Horn-Strobes Horns Multi-cd Wall Strobes(G1-VM) Wall or Ceiling Mounted UL 15 cd* 30 cd* 15/75 cd** 75 cd* 110 cd* Temporal Horns(G1-HD) _._.. ..__--------------- Rating RMS RMS RMS RMS RMS UL High dB Low dB 16 Vdc 103 141 152 255 311 Rating (RMS) (RMS) _ — 16 Vfwr 125 179 224 346 392 16 Vdc 26 19 "G1-VM multi-cd;**G1 F-V1575 fixed 15/75 cd 24 Vdc 36 27 33 Vdc 41 33 Typical 15 cd 30 cd 15/75 75 cd 110 cd 16 Vfwr ® 37 Current RMS RMS RMS RMS RMS 24 Vfwr 69 52 16 Vdc 85 127 150 245 285 33 Vfwr 76 70 20 Vdc 71 98 123 188 240 _ 24 Vdc 59 82 104 152 191 Typical High dB Low dB 33 Vdc 46 64 84 112 137 Current_ _ RMS RMS 16 Vfwr 119 169 223 332 376 16 Vdc 22 17 20 Vfwr 103 143 189 253 331 20 Vdc 24 19 24 Vfwr 94 129 169 218 _ 262 —24 Vdc 27 22 33 Vfwr 87 112 148 179 205 33 Vdc 32 26 -rn - 16 Vfwr 34 30 Wall Temporal Horn-strobes—High dB Setting 20 Vfwr 40 34 15 30 15/75 75 110 *G1-HDVM multi-cd 24 Vfwr 45 38 UL cd* cd* cd** cd* cd* **G1 F-HDV1575 fixed 15/75 cd 33 Vfwr 52 47 Rating RMS RMS RMS RMS RMS 16 Vdc 129 167 172 281 337 Wall or Ceiling Mounted Horns(G1-P) 16 Vfwr 176 230 269 397 443 Max.Current, UL Designation Voltage Range RMS Typical 15 cd ____ 30 cd 15/75 75 cd 110 cd Regulated 24 16 33 Vdc 13 mA Current RMS RMS RMS RMS RMS Vdc 16 Vdc 102 135 160 246 309 24 fwr 16-33 Vfwr 11 mA 20 Vdc 88 109 137 193 248 24 Vdc 81 94 122 161 203 Typical Current RMS .. . 33 Vdc 74 72 106 124 154 24 Vdc 10 ...... 16 Vfwr 144 182 247 352 .39 393....._* 24 Vdc 11 20 Vfwr 141162 — 220 274 362 31 Vdc 12 24 Vfwr 136 152 203 235 282 20 Vfwr 9 33 Vfwr 125 144 196 201 232 24 Vfwr 10 Wall Temporal Horn-strobes-Low dB Setting Current values are shown in mA. L 15 30 15/75 75 110 U Uting cd* cd* cd** cd* cd* RMS RMS RMS RMS RMS 16 Vdc 122 160 146 274 330 *G1-HDVM multi-cd 16 Vfwr 162 216 231 383 429 **G1 F-HDV1575 fixed 15/75 cd Typical 15 cd 30 cd 15/75 75 cd 110 cd Current RMS RMS RMSRMS RMS • 16 Vdc 96 130 158 243 302 20 Vdc 79 104 133 189 241 24 Vdc 68 88 119 156 197 33 Vdc 56 71 100 118 146 017..: 128 180 241 344 389 20 Vfwr 118 157 213 266 343 24 Vfwr 113 144 195 230 279 33 Vfwr 112 137 182 197 226 Page 3 of 6 85001-0573 ;t Issue 11.1 dBA output Average Sound Output (dBA) Temporal Horns,Horn-strobes(G1-HD,G1-HDVM series) (High dB setting,anechoic,24V, measured at 10ft) High UL464 Average Peak da o„o,�m � ," � � " � zo ,o oe " � <" o � m 100 110 120 d6 Temporal/ Temporal/ -8°° Temporal Steady Setting Steady Steady 16 Vdc 81.4 85.5 91.4 94.2 24 Vdc 84.4 88.6 94.5 97.6 33 Vdc _ 86.3 90.4 96.9 99.5 �0° sOe Low dB UL464 Average Peak LS"., 45° TemporaU Temporal! Setting Temporal Steady , Steady Steady 16 Vdc 76.0 80.1 86.3 89.2 15" 0° 15° 24 Vdc 79.4 83.5 89.8 92.5 33 Vdc 82.1 86.5 92.5 95.3 Light output - (effective cd) Steady Tone Horns(G1-P series) Percent of UL rating versus angle UL464 Average Peak 16 Vdc 77_dBA,min 85 dBA 91 dBA 120„a 100 so ao ,o s” 50 40 30 20 o o 10 p 30 .o �m „ ,o o" o 120 90. 16 Vfwr 77 dBA,min 85 dBA 91 dBA / Notes -75'x\ 75" 1. All values shown are dBA measured at 10 feet(3.01 m). 2. UL464 values measured in reverberant room. fi0 60 3. Average and Peak values are measured in anechoic chamber. 45 45' 30^...... 30° Specifications Housing Red or white textured UV stabilized,color impregnated engineered plastic.Exceeds 94VT0 UL flammability rating. Lens Optical grade polycarbonate(clear) Strobes and horn-strobes are for wall-mount installation only.Horn-only models may be ceiling-or wall-mounted. Mounting Flush mount:21/2 inch(64 mm)deep one-gang box (indoor only) Surface mount: Model 27193 surface mount box,wiremold box,or equivalent surface-mount box With optional trim plate:One-gang,two-gang,four-inch square,octagonal,or European single-gang box Wire connections Screw terminals:single input for both horn and strobe.#18 to#12 AWG(0.75 mm2 to 2.5 mm2)wire size Operating environment Indoor only:32-120°F(0-49°C)ambient temperature.93%relative humidity _ Agency listings/approvals UL 1971 (S218),UL 1638(S218),UL 464(S218),ULC S525,ULC S526,CSFM,CE, FCC,MEA. (All models comply with ADA Code of Federal Regulation Chapter 28 Part 36 Final Rule.) Dimensions(HxWxD) Signal:4-1/2"x 2-3/4"x 13/16"(113 mm x 68 mm x 21 mm) Trimplate: 5"(127 mm);Height—5-7/8"(149 mm);Depth—1/2"(13 mm) G1-HD series temporal-tone horns:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR(or coded when horn set to steady tone) Operating voltage G1-HDVM series temporal-tone horn-strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR (or coded (audible NAC only)when used with optional G1 M Genesis Signal Master) G1-VM series strobes:non-coded,filtered 16-33 Vdc or unfiltered 16-33 Vdc FWR G1-P series steady-tone horns:coded or non-coded,filtered 20-31 Vdc or unfiltered 20-27 Vfwr UL 1971,UL 1638,ULC S526:selectable 15 cd,30 cd,75 cd,or 110 cd output Strobe output rating UL 1971: 15 cd(fixed 15/75 cd models) UL 1638,ULCS526:75 cd(fixed 15/75 cd models) G1-VM strobes and G1-HDVM series temporal-tone horn-strobes:one flash per second synchronized with optional Strobe flash rate G1 M Genesis Signal Master indefinitely within 10 milliseconds.Temporal setting(private mode only):synchronized to temporal output of horns on same circuit SIGA-CC1S,SIGA-MCC15,SIGA-CC2A,SIGA-MCC2A,G1M-RM Synchronization Sources BPS6A,BPS10A,APS6A,APS10A,i064,i0500,Fireshield Plus 3,5 and 10 zone. Add G1 M for G1-CVM&G1-HDVM devices only. Horn pulse rate G1-HD temporal-tone horns and G1-HDVM series temporal-tone horn-strobes:temporal rate synchronized with optional G1 M Genesis Signal Master indefinitely within 10 milliseconds.G1-P steady-tone horns:continuous,steady tone only Temporal audible pattern 1/2 sec ON,1/2 sec OFF,1/2 sec ON,1/2 sec OFF,1h sec ON, 11/2 sec OFF,then repeat cycle Page 4 of 6 85001-0573 Not to I,. ii..->cc. .v, Issue 11.1 Candela Output Fire appliances available with white or red housings. Lens Switch Switch Switch Switch SA v tk t F s.1 Rating Position Position Position Color Position A B C D e=� FIRE E Amber UL 1638 110 cd 75 cd 30 cd 15 cd \ �����\ e '� Amber UL 1971* 88 cd 60 cd 24 cd 12 cd � Clear UL 1971 110 cd 75 Cd 30 Cd 15 cd ECS/MNS appliances available with clear or amber lenses. *Equivalent Rating A A LI L \ E I� E ALERT T T. fr ALERT =ma - Ordering Information Model I Housing I Marking I Lens I Strobe I Horn I Ship Wt.lbs(kg) Fire Alarm Appliances(clw running man icon screen printed on housing) G1-VM White None Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) G1 F-HD White FIRE Clear Horn only Selectable high/low dB 0.25 (0.11) G1 F-HDV1575 White FIRE Clear 15/75 cd' Temporal hi/lo dB-24V 0.25 (0.11) G1 F-HDVM White FIRE Clear Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) _G1 F-P White FIRE Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) - _G1 F-V1575 White FIRE Clear 15/75 cd1 Strobe only 0.25 (0.11) `G1FVM White FIRE Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) G1-HD White None Clear Horn only Selectable high/low dB 0.25 (0.11) 01-HDVM White None Clear Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) G1-P White None Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) G1RF-HD Red FIRE Clear Horn only Selectable high/low dB 0.25 (0.11) G1 RF-HDV1575 Red FIRE Clear 15/75 cd1 _ Temporal hi/lo dB-24V 025 (0.11) G1 RF-HDVM Red FIRE Clear Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) G1 RF-P Red FIRE Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) G1 RF-V1575 Red FIRE Clear 15/75 cd1 Strobe only 0.25 (0.11) G1 RF-VM Red FIRE Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) G1R-HD Red None Clear Horn only Selectable high/low dB 0.25 (0.11) G1R-HDVM Red None Clear Selectable 15,30,75,or 110 cd Selectable high/low dB 0.25 (0.11) G1 R-P Red None Clear Steady Horn(not compatible with Genesis Signal Master) 0.25 (0.11) G1 R-VM Red None Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) ECS/MNS Appliances(no running man icon on housing) _ G1 WA-VMA White ALERT Amber Selectable A,B,C or D Strobe only 0.25 (0.11) G1 WA-VMC White ALERT Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) G1 WN-VMA White None Amber Selectable A,B,C or D Strobe only 0.25 (0.11) G1 WN-VMC White None Clear Selectable 15,30,75,or 110 cd Strobe only 0.25 (0.11) Trim Plates G1T White None Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) G1 RT Red None Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) G1T-FIRE White RRE Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) G1 RT-FIRE Red FIRE Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) G1 WT-ALERT White ALERT Genesis Trim Plate(for two-gang or 4"square boxes) 0.15(0.7) Surface Boxes • 27193-16 4,1111b 1 i(A 'e,is-yai iy aui law I I 1uu1 n uun r .tet 27193-11 Red N/A One-gang surface mount box 1 (0.4) 1 These 15/75 cd models provide fixed output and are not multi-candela devices.The 15 cd output component complies with UL1971,while the 75 cd output component complies with UL 1638. Page 5 of 6 85001-0573 Issue 11.1 c_EDWAR DS Contact us... Email: edwards.fire@fs.utc.com Web: www.est-fire.com EST is an EDWARDS brand. 1016 Corporate Park Drive Mebane,NC 27302 In Canada,contact Chubb Edwards... Email: inquiries@chubbedwards.com Web: www.chubbedwards.corn ©2013 UTC Fire&Security Americas Corporation,Inc.All rights reserved. Specifications subject to change without notice.Edwards is part of UTC Climate,Controls&Security,a unit of United Technologies Corporation. 0 rn Page 6 of 6 85001-0573 Issue 11.1