Loading...
Permit (49) CITY OF TIGARD ELECTRICAL PERMIT fpq ''' COMMUNITY DEVELOPMENT Permit#: ELC2018 00264 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 07/16/2019 Parcel: 251010001600 Jurisdiction: Tigard Site address: 7790 SW HUNZIKER RD Project: The Fields Apartments-Building 3-Clubhouse Subdivision: FIELDS APARTMENTS Lot: None Project Description: Building 3-Electrical for new 1-story clubhouse. Contractor: ERIC OLSON ELECTRIC COMPANY Owner: FIELDS, FRED W REVOCABLE LIVING 10013 NE HAZEL DELL AVE PMB 432 111 SW 5TH AVE#3675 VANCOUVER,WA 98685 PORTLAND, OR 97204 PHONE: 360-609-4901 PHONE: FAX: 360-693-2980 FEES Quantity Description Date Amount 1 ea Services or Feeders-200 07/16/2019 $100.70 Specifics: amps or less 40 crt Branch Circuits w/Purchase 07/16/2019 $296.80 Type of Use: COM Service or Feeder Class of Work: NEW 1 ea Plan Review Electricial 07/16/2019 $99.38 Type of Const: 1 ea 12%State Surcharge- 07/16/2019 $47.70 Occupancy Grp: Electrical 4 ea Info Process/Archiving-Lg 07/16/2019 $8.00 $2.00(over 11x17) Total $552.58 Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: r ✓ Permittee Signature: l OWNER INSTALLATION ONLY The installation is being made on property I own which is not intended for sale,lease or rent. OWNER'S SIGNATURE Date: CONTRACTOR INSTALLATION ONLY SIGNATURE OF SUPR.ELEC' Date: LICENSE NO. Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Electrical Permit ApplicatiC (j 1 t l I OR 01 I I( I 1 'l. OSI , City of Tigard Received • : Permit#: 1. _ N.- 71I 4 13125 SW Hall Blvd,Tigard,OR 97223I� 1 G Plan Review g Phone: 503.718.2439 Fax 503.598.1960U Date/B : 0=111111111111111111 llCiAInspection Line 503.639 4175 r%«+ liiirii..�F ReadybatuBy; B Set Page 2 for ll.l EMI Internet www ttgard-or gov : /IC ,1,,, Notified/Method: Supplemental Information . . _ . l ke) 3x 0 New construction 0 Addition/alteration/replacement Please cheek all that apply(submitl sets of plans wJtems checked): ��Service or feeder 400 amps or more - Building over three stories. ❑Demolition 'M 0 Other: where the available fault current 0 Marinas and boatyards. . +.,, ., '� a) ,:or. 01�,. ,,,a `„, `, -'• "'.',4,,,,....41 exceeds 10,000am at 150voltsor hair .. y amps ❑Floating buildings. El1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ®Multi-family 0 Master builder 0 Other: 0 Fire pump 0 Installation of 150 KVA or 4, , '' > Emergency Y larger separately derived �:��'°. �s� �. .,„.} �)t'� _t :Is 5 ., �-, DGmar en system. lob 4: Job site address:7790 SW Hunziker Rd 0 Addition of new motor load of system. �� I OOHP or more. ❑"A”"E "l-2" "1.3' City/State/ZIP:Tigard,OR 97223 , Six or more residential units. occupancy. ❑Health-care facilities. 0 Recreational vehicle parks. Suite/bldg,/apt.#:3 l Project name:The Fields Apartments 0 Hazardous locations. 0 Supply voltage for more than ®Sen ice or feeder 600 amps or more. 600 volts nominal Cross street/directions to job site:SW Hunziker RD&SW Wall St „_= ,, PEE 1. 5l 1 X ,g,:..,41,-,V Desrription r�Qty. Earn I TotaI • New residential single-or multi-family dwelling unit, Subdivision: J Lot 4: Includes attached garage. 1,000 sqft.or less 168,54 4 Tax map/parcel# 2S1010001600 Ea.add',500 sq.ft.or portion 33.92 I .01`;'.:,:.(2,,_ a"� 's'p s a° 2,177,:707,5 Limited energy,residential 75.00 2 I STORY WOOD FRAMED CLUBHOUSE WITH LEASING OFFICE AND (with above sq.ft) Limited energy,multi-family 75.00 2 AMMENITY SPACES residential(with above sq.ft.) Renewable Energy 0 See Page 2 ' ii `PROP it3 Y I I `" '_ °' M' ' , � ..r°, r:a',-, :' Services or feeders installation,alteration,and/or relocation Name:Fred W,Fields Revocable Living Trust 200 amps or less 1 100.70 100.70 2 Address: 111 SW 5111 Ave,#3400 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/Z1P:Portland,OR 97204 601 amps to 1,000 amps 301.04 2 Phone:(503)205-2332 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 I I intended for sale,lease,rent,or exchange.according to ORS 447,449,670,and 701. 201 amps to 400 amps 125,08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 '',.:.(:','n” Branch circuits-c ew,alteration,or extension, er panel ►:+ APPLICAI!(I • y,:,V :,4 CONTA • '' '' A.Fee for branch circuits with Business name:Otak Architects,Inc above service or feeder fee, 40 742 296.8 2 each branch circuit Contact name:Matt Neish,RA,AIA B.Fee for branch circuits without service or feeder fee,first Address:808 SW 314 Ave,Ste 300 branch circuit 56.18 2 City/State/ZIP:Portland,OR 97204 Each add'1 branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(503)415-2393 Fax: :( ) Each manufactured or modular 6784 Email:matt.neishfa..otak.com dwelling,service and/or feeder f''_,'` , N.-,• wa FRAG'1' R t".., , . Reconnect only 67.84 2 ,., � � - - � � Pump or irrigation circle 67,84 2 Business name:Eric Olson Electric Inc Sign or outline lighting 67.84 2 Address: 10013 NE Hazel Dell Ave PMB 432 Signal circuit(s)or limited energy ❑ See Pagee 2 2 panel,alteration,or extension City/State/ZIP:Vancouver,WA 98685 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(360)258-1849 Fax:( ) Investigation(1 hr min) 90.00/hr Email:jeff@ericolsonelectricinc.com Industrial plant(1 hr min) 7R.181 hr Inspections for which no fee is 90.{)p hr CCB Lie': 179408 Electrical Lie.: 37-10530 Suprv.Lie.: 4910S specifically listed(' hr min) 141/1, EL>F.PTRIC:AL PERMIT. PEI , , r. ,,x, Suprv.Electrician signature,required:0 f u,.�---.., Subtotal Print name: ' -i�i /JG� Date: CO3 Iz_O/?" Ei Plan Review Required(25%of permit fee):_ State surcharge(12%of permit fee). _ Authorized signature: eyra�� TOTAL PERMIT FEE This permit application expires if a permit is not obtained within IRO Print name: Matt Neish Date: 6/13/2019 days after it has been accepted as complete. ' Number of inspections allowed per permit. I:' wldinaPareata'.Et.C;PonnaApp_ELR_ERE.doc Rev no:17'2015 d40.1615T(11/05/COM/wEa Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: FEE SCUP WORK ONLY: 3: Deacription (Qty. l Each I Total • Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5 01 to 15 kva 133 56 2 • Audio and Stereo Systems* 15 01 to 25 Irsa 200 34 2 Wind generation systems in excess of 25 km Ej Burglar Alarm 25.0!to 50 kva 301.04 2 50 01 to 100 kva 552 26 2 E Garage Door Opener* >100 kva(fee in accordance 552 26 2 with OAR 918-309-0040) El Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 742 3 E Vacuum Systems* -5100 kva—no additional charge 00 3 Each additional inspection over allowable in anxof the above: C Each additional inspection IS 66.25)hr 1 Other: charged at an hourly(I hr min) Inspections for which no fee is 90 00/hr specifically listed tt-1 hr nun) • A.: I r 4'• O • NLY: Subtotal(Enteron Page I) Fee for each commercial system: $75.00 Number of inspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: LI Audio and Stereo Systems O Boiler Controls O Clock Systems O Data Telecommunication Installation O Fire Alarm Installation LI HVAC D Instrumentation O Intercom and Paging Systems D Landscape Irrigation Control* O Medical O Nurse Calls LI Outdoor Landscape Lighting* LI P• rotective Signaling 11 O• ther: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations ,tikblcItnaRermaTt _Pen.$IAppUJFREik Re v OS 17 201'5 - 1 Electrical Permit Application 'l t1- t 1 V FOR OFFICE USE ONLY • - ' City of Tigard ADP 9 c3 20 Date/Bea �/ ti� ?., ✓y'' — 13125 SW Hall Blvd.,Tigard,OR 97223 //14-, ''.*1' ll 1 +i Phone: 503.718.2439 Fax: 503.598.1960 (" Plan Review 1.© � �, Date/B `�,J Related Permit#: Inspection Line: 503.639.4175 % `' TIGARD 1 `�e afar, :-.1--t'; ReadyDate/By: , t �I ® See Pagel for Internet: www'.tigard-or.gov '' > Notified/Method:,4,r '///,..;-'• Supplemental Information TYPE OF WORK ': 4' rt4,-- PLAN REVIEW ®New construction 0 Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): 0 Demolition ❑Other: ®Service or feeder 400 amps or more ®Building over three stories. where the available fault current • ❑Marinas and boatyards. CATEGORY OF CONSTRUCTION exceeds 10,000 amps at 150 volts or 0 Floating buildings. 0 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Conm,erciat-use agricultural amps for all other installations. buildings. ®Multi-family 0 Master builder 0 Other: ❑Fire pump. El Installation of 150 KVA or JOB SITE INFORMATIONAND LOCATION El Emergency system. larger separately derived ❑Addition of new motor load of system. Job 4: Job site address:7790 SW Hunziker Rd IOOHP or more. ❑"A° °`E","1-2",°`1-3' City/State/ZIP:Tigard,OR 97223 ®Six or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.4:3 Project name:The Fields Apartments ❑Hazardous locations. ❑Supply voltage for more than ®Service or feeder 600 amps or more. 600 volts nominal Cross street/directions to job site:SW Hunziker RD&SW Wall St FEE SCHEDULE Description 1 Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot 4: Includes attached garage. Tax map/parcel 4:2S1010001600 1,000 sq.ft.or less 168.54 4 Ea.add'l 500 sq.ft or portion 33.92 1 " DESCRIPTION OF WORK Limited energy,residential 1 STORY WOOD FRAMED CLUBHOUSE WITH LEASING OFFICE AND (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 AMMENITY SPACES residential(with above sq.ft.) PROPERTY OWNER 0 TENANT RenewESeP2 Services able or feedersnergy installation,alteratio❑ en,aagend/or relocation Name:Fred W.Fields Revocable Living Trust c/o Miller Nash Graham&Dunn LLP 200 amps or less 1 100.70 100.70 2 Address: 111 SW 5th Ave,#3400 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Portland,OR 97204 601 amps to 1,000 amps 301.04 2 Phone:(503)205-2332 Fax:( ) Over 1,000 amps or volts 552.26 2 Email: Temporary services or feeders installation,alteration,and/or relocation Owner installation: This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 El APPLICANT @ CONTACT PERSON Branch circuits—new,alteration,or extension,per panel A.Fee for branch circuits with Business name:Otak Architects,Inc above service or feeder fee, 40 7 42 296.8 2 each branch circuit Contact name:Matt Neish,RA,AIA B.Fce for branch circuits without Address:808 SW 3'I Ave,Ste 300 service or feeder fee,first 56.18 2 branch circuit City/State/ZIP:Portland,OR 97204 Each add'I branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(503)415-2393 Fax: :( ) Each manufactured or modular Email:matt.neish@otak.com dwelling,service and or feeder 67.84 2 Reconnect only 67.84 2 \ ir s' 10CO1 to T -, ; . .1L4.,. .;: . ;.<, Pump or irrigation circle 67.84 2 =--Business name:DBG Properties LLC Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address:2164 SW Park Place panel,alteration,or extension. ❑ See Page 2 2 City/State/ZIP:Portland,OR 97205 Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(503)816-4084 Fax:( ) Investigation(1 hr min) 90.00/hr Email: Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is CCB Lic.: 201911 Electrical Lic.: Suprv.Lic.: specifically listed(/hr min) 90.00/hr ELECTRICAL'PERMIT FEES Suprv.Electrician signature,required: Subtotal: Print name: Date: ®Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: 4111 ::::) TOTAL PERMIT FEE: 14.4s) This permit application expires if a permit is not obtained within.180 Print name: Matt Neish Date: 4/23/2018 days after it has been accepted as complete. * Number of inspections allowed per permit. I:\.Building\Permits\ELC_PerrnitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: RESIDENTIAL WORK ONLY: FEE SCHEDULE Description I Qty I Each I Total I * Fee for all residential systems combined: $75.00 Renewable electrical energy systems: 5 kva or less 100.70 2 Check Type of Work Involved: 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kvafee in accordance kva(fee 2 with OAR 918-309-0040) ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7 42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed('/hr min) ELECTRICAL PERMIT COMMERCIAL WORK ONLY, FEESe Subtotal(Enter on Page I)):: Fee for each commercial system:+ $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I\Building\Permits'ELC PermitApp ELR ERE.doe Rev 06/17/2015 IICOMcheck Software Version 4.0.7.0 Interior Lighting Compliance CertificateRECEIVED Section 1: Project Information RSR 2 3 2018 CITY OF i iGARO Energy Code:2014 Oregon Energy Efficiency Specialty Code 3tJIL nING niviSlCJ Project Title: The Fields Apartments Bldg 3 Project Type: New Construction Construction Site: Owner/Agent: Designer/Contractor: 7840 SW Hunziker Rd Otak Architects MFIA, Inc Tigard,OR 97223 808 SW 3rd Ave,Suite 300 2007 SE Ash St Portland,OR 97204 Portland,OR 97214 Section 2: Interior Lighting and Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts/ft2 (B x C) Clubhouse(Common Space Types:Office-Enclosed)(Ceiling Height 10 ft.) 3358 0.99 3324 Total Allowed Watts= 3324 (a) Allowed watts per sq.ft.adjusted for ceiling height. Section 3: Interior Lighting Fixture Schedule A B C D E Fixture ID:Description/Lamp/Wattage Per Lamp/Ballast Lamps/ #of Fixture (C X D) Fixture Fixtures Watt. Clubhouse(Common Space Types:Office-Enclosed 3358 sq.ft.) LED 1:B2/B2E:downlight:LED Panel 33W: 1 32 35 1120 LED 2:B3:wallwash:LED Panel 33W: 1 5 35 175 LED 3:Al:Strip: LED Linear 22W: 1 9 25 225 LED 4:D/DE:pendant: LED Linear 22W: 1 7 25 175 LED 5:X:Exit:LED A Lamp 2.5W: 1 7 5 35 Total Proposed Watts= 1730 Section 4: Requirements Checklist In the following requirements, blank checkboxes identify requirements that the applicant has not acknowledged as being met. Checkmarks identify requirements that the applicant acknowledges are met or excepted from compliance. 'Plans reference page/section'identifies where in the plans/specs the requirement can be verified as being satisfied. Lighting Wattage: • 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Wattage:3324 Proposed Wattage: 1730 Complies:YES - Mandatory Requirements: ✓ 2. Exit signs.Internally illuminated exit signs shall not exceed 5 watts per side. Plans reference page/section: ✓ 3. Daylight zone control.All daylight zones are provided with individual controls that control the lights independent of general area lighting in the non-daylight zone.In all individual daylight zones larger than 350 sq.ft.,automatic daylight controls is provided.Automatic daylight sensing controls reduce the light output of the controlled luminaires at least 50 percent,and provide an automatic OFF control, while maintaining a uniform level of illumination.Contiguous daylight zones adjacent to vertical fenestration may be controlled by a single controlling device provided that they do not include zones facing more than two adjacent cardinal orientations(i.e.,north,east, south,west).Daylight zones under skylights shall be controlled separately from daylight zones adjacent to vertical fenestration. Plans reference page/section: Project Title: The Fields Apartments Bldg 3 Report date: 04/18/18 Data filename: G:\Otak\9547_Fields Apartments\Energy Forms\9547 Fields Apt Clubhouse.cck Page 1 of 3 ✓ 4. Interior lighting controls.At least one local shutoff lighting control has been provided for every 2,000 square feet of lit floor area and each area enclosed by walls or floor-to-ceiling partitions.The required controls are located within the area served by the controls or-are a remote switch that identifies the lights served and indicates their status. Plans reference page/section: ✓ 5. Sleeping unit controls.Master switch at entry to hotel/motel guest room. Plans reference page/section: ✓ 6. Egress lighting.Egress illumination is controlled by a combination of listed emergency relay and occupancy sensors to shut off during periods that the building space served by the means of egress is unoccupied. Plans reference page/section: ✓ 7. Additional controls.Each area that is required to have a manual control shall have additional controls that meet the requirements of Sections 505.2.2.1 and 505.2.2.2. Plans reference page/section: ✓ 8. Light reduction controls.Each space required to have a manual control also allows for reducing the connected lighting load by at least 50 percent by either 1)controlling(dimming or multi-level switching)all luminaires;or 2)dual switching of alternate rows of luminaires,alternate luminaires,or alternate lamps;or 3)switching the middle lamp luminaires independently of other lamps;or 4)switching each luminaire or each lamp. Plans reference page/section: ✓ 9. Buildings larger than 2,000 square feet are equipped with an automatic control device to shut off lighting in those areas.This automatic control device shall function on either: 1)a scheduled basis,using time-of-day,with an independent program schedule that controls the interior lighting in areas that do not exceed 10,000 square feet and are not more than one floor;or 2)an occupant sensor that shall turn lighting off within 30 minutes of an occupant leaving a space;or 3)a signal from another control or alarm system that indicates the area is unoccupied. Plans reference page/section: ✓ 10.Occupancy sensors in rooms that include daylight zones are required to have Manual ON activation. Plans reference page/section: ✓ 11 An occupant sensor control device is installed that automatically turns lighting off within 30 minutes of all occupants leaving a space. Plans reference page/section: ✓ 12Additional controls.An occupant sensor control device that automatically turns lighting off within 30 minutes of all occupants leaving a space or a locally activated switch that automatically turns lighting off within 30 minutes of being activated is installed in all storage and supply rooms up to 1000 square feet. Plans reference page/section: ✓ 13.Occupant override.Automatic lighting shutoff operating on a time-of-day scheduled basis incorporates an override switching device that: 1)is readily accessible,2)is located so that a person using the device can see the lights or the area controlled by that switch,or so that the area being lit is annunciated,3)is manually operated,4)allows the lighting to remain on for no more than 2 hours when an override is initiated,and 5)controls an area not exceeding 2,000 square feet. Plans reference page/section: ✓ 14.Holiday scheduling.Automatic lighting shutoff operating on a time-of-day scheduled basis has an automatic holiday scheduling feature that turns off all loads for at least 24 hours,then resumes the normally scheduled operation. Plans reference page/section: ✓ 15.Exterior lighting controls.Lighting not designated for dusk-to-dawn operation shall be controlled by either a combination of a photosensor and a time switch,or an astronomical time switch. Lighting designated for dusk-to-dawn operation shall be controlled by an astronomical time switch or photosensor. Plans reference page/section: ✓ 16.Tandem wiring.The following luminaires located within the same area shall be tandem wired: 1.Fluorescent luminaires equipped with one,three or odd-numbered lamp configurations,that are recess-mounted within 10 feet center-to-center of each other. 2. Fluorescent luminaires equipped with one,three or any odd-numbered lamp configuration,that are pendant-or surface-mounted within 1 foot edge-to-edge of each other. Plans reference page/section: ✓ 17.Medical task lighting or art/history display lighting claimed to be exempt from compliance has a control device independent of the control of the nonexempt lighting. Project Title: The Fields Apartments Bldg 3 Report date: 04/18/18 Data filename: G:\Otak\9547_Fields Apartments\Energy Forms\9547 Fields Apt Clubhouse.cck Page 2 of 3 Plans reference page/section: ✓ 18.Each dwelling unit in a building is metered separately. Plans reference page/section: Interior Lighting PASSES:Design 8%better than code, Section 5: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans,specifications and other calculations submitted with this permit application.The proposed lighting system has been designed to meet the 2014 Oregon Energy Efficiency Specialty Code requirements in COMcheck Version 4.0.7.0 and to comply with the mandatory requirements in the Requirements Checklist. Ron Mart-MFIA Ronald E Mart 04.18.2018 Name-Title Signature Date Project Title: The Fields Apartments Bldg 3 Report date: 04/18/18 Data filename: G:\Otak\9547_Fields Apartments\Energy Forms\9547 Fields Apt Clubhouse.cck Page 3 of 3