Loading...
Report (80) OFFICE COPY .k\c\ �v\Q- (DG-kgii • \ SLS ITYMULT MODE LFY-P12 nniT s ArikELE Job Name:Tigard Westside Cancer Center System Reference: FCU-4,5,6,7 Date:4/30/2019 r j; .ø!I! fy i s BUILDii 4 LJ vioiON GENERAL FEATURES • Square edge,sleek design • 3D i-see SensorTM available as an option • Improved installation features1 • Occupancy detections • Energy saving features1 • Improved occupant comfort • Four fan speed settings including auto-fan • Individual vane settings • 2'x 2'size matches size of many ceiling tiles • Corner-pocket design for simplified installation • Built-in condensate lift mechanism designed to provide up to 33"of lift • Ventilation air intake supported Turner Smile by: Eric Mishler Date: 05/21/2019 Reviewed by Turner for General compliance with the contract documents only,This review does not relieve the subcontractor of the responsibility for making the work confrom to the requirements of the contract.The subcontractor is responsible for all dimensions,correct fabrication and accurate fit with the work of other trades. Submittal Number: 238126-03 1Requires a PAR-33MAA-J controller Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC o i Axa- LFY 1 \ Nominal Capacity1 Cooling Btu/h 12,000 Heating Btu/h 13,500 Electrical Electrical Power Requirements 1-phase 208-230V 60Hz Minimum Circuit Ampacity(MCA) A 0.29 Recommended Fuse Size A 15 External Dimensions(H x W x D) Unit in.(mm) 8-3/16 x 22-7/16 x 22/7-16(208 x 570 x 570) Grill(SLP-18FAU) in.(mm) 13/32 x 24-19/32 x 24-19/32(10 x 625 x 625) Net Weight Unit lbs(kg) 31.3(14.2) Grill(SLP-18FAU) ! lbs(kg) 5.3(2.4) External Finish Unit Galvanized steel sheet Grill(SLP-18FAU) Munsell 1.0Y 9.2/0.2 Coil Type Cross fin(Aluminum fin and copper tube) Fan Type x Quantity Turbo fan x 1 Airflow rate I CFM 245-280-335 Motor Type DC motor Motor Output [ kW 0.05 Motor F.L.A. A 0.23 Air Filter PP honeycomb fabric(long life type) Refrigerant Piping Diameter Liquid(High Pressure) in.(mm) 1/4(6.35)Flare Gas(Low Pressure) in.(mm) 1/2(12.7)Flare Field Drain Pipe Size in.(mm) O.D.1-1/4(32) Sound Pressure Level(Low-Mid-High) dB(A) 26-30-34 1 Cooling/Heating capacity indicated at the maximum value at operation under the following conditions: Cooling Indoor:81°F(27°C)DB/66°F(19°C)WB;Outdoor 95°F(35°C)DB Heating I Indoor:68°F(20°C)DB;Outdoor 45°F(7°C)DB/43°F(6°C)WB Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC • ACCESSORIES: PLFY-PI2NFMU-E Grille(required) ❑SLP-18FAU Grille with 3D i-see SensorTM ❑SLP-18FAEU Corner Panel with 3D i-see SensorT — ❑PAC SF1 ME-E "" Signal Receiver Corner Panel ❑PAR-SF9FA-E Wireless Remote Controller ❑PAR-FL32MA-E Wireless Remote Controller ❑PAR-SL100A-E Wireless Remote Receiver ❑PAR-FA32MA-E Wired MA Controller I PAR-33MAA-J Simple MA Controller ❑PAC-YT53CRAU Smart ME Remote Controller ❑PAR-U01 MEDU-K Wired Remote Sensor ❑PAC-SE41 TS-E Thermostat Interface ❑PAC-US444CN-1 Wireless Interface ❑PAC-WHS01 WF-E Connector cable for remote display ❑PAC-SA88HA-EP Connector for CN32(remote on/off) o PAC-SE55RA-E Remote Operation Adapter(with wire terminals for remote ON/OFF and operation status/error) ❑PAC-SF40RM-E1 External Fan/Heater Control Relay Adapter ❑CN24RELAY-KIT-CM3 Drain Pan Level Sensor(Control for indoor unit shut off to prevent drain pan overflow) ❑DPLS2 1 Unable to use with wireless remote controller ©2018 Mitsubishi Electric Trane HVAC US LLC Specifications are subject to change without notice. DIMENSIONS:Pt P1NFM y, � Unit: inch(mm) CRAIN PIPE REFREERENT PIPE IGA9.1.121r12.71 1/416 7-23/3211961 7-23/3211961 VP-b E. ET. IIIIIIIIIIII c FLARED CphECTpN�V2F II SUSPENSION BOLT —I a ' �� FLARED EDI PIPE ILIDUEN.V2P.14LI1• I' MIO OR W3/B HI i, 6 / FLAREDCONNECTEN.VLF Ivo1 ••♦ — L_' EL m ����II __J__._ eill, m-'Iln� " �, �'1'>J� ,._� _J1 Vial nn• oA1TAne en+n-nnasom(ENrrE PERIPFIERYI I• r •lei! I = 17 23 H501 !! �,I ,� r I /16)5723/32 5-29/32 22-7/761570r -- ,- _ _ 20-21/321525) N FOR REIb BL CONTRDLLER POWER SUPPLY - c 11/1 -7/1 SUSPENSION BOLT PITCH 3 -lit N TERNNAL BLOC TERMNAL BLOC. -7l1• 7-7/16 = _n NDOOR/WTDDER UNT n rvN 11 N CONN24-19 T216251 BLOCK GRELE WpKT ENTRY om '^m ry 24-19/32(625) N _m�u 144/ 1361 12-7/32(310) RECEIVER CORNER PAnEL ry u1 of 7 nl1D 1-../3 1-13/32 AIR INTAKE HOLE Z / NDTHNG N THE CASE DF• •• 6,- C mX ilir, n 111 �Q, STA14lARp PAIEL - a �,I _ __ _ '- new. 1,1 QZl,IHI GRN.LE __. �" GRAN YKl y laC li_ .�_. �f� iII of WS I`I— a h 1 11 o _m [141 . v FSEE SENSOR CORFER T P05( / I �� STANIMRD ATTATIIlIFNT P06RION VANE BTW ___ ________________ 16-1/1614081 r .NOTHING N TIE CASE OF AUTO RAKE 1 DETAILS OF RECEIVING ns-2As1 (73.E2645, STANDARD PAIR -- j 9/32 TO 3V32 22-11/16 TO 24-V32(576-6101 CEILING HOLE 9/32 TO 3V32,i ,, ,11111111111111111=11 i RE ' i _ 2fEa811: m -T- /f Itiii 1 m N m Oai► I PR60ST/STAN)BT n r1 _ I I �•� - 12-7/8(17..4)A T.T HOLE EMERGENCY OPERATON EIERCt?d:Y OPERATOIK FRESH AIR NTAKE L-_--SWITCIMIEATNO _.._-.SWR[MICOOLNG)-..J AfftW. MITSUBISHI ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll Free:800-433-4822 www.mehvac.com ceus FORM#PLFY-P12NFMU-E-201806 Intertek Specifications are subject to change without notice. ©2018 Mitsubishi Electric Trane HVAC US LLC • ITYM CCTe PAR- -� MA REMOTE CONTROLLER MW ELECTRIC Job Name: Tigard Westside Cancer Center System Reference: FCU-4,5,6,7 Date: 4/30/2019 A.t 14:38 Fn 14:38 Yams eoon,28.s '9 °, C4Q1sett£e 41 d + FI I t:73 /41mb. 0 , 40, Full View Basic View CAPABILITIES • Basic Operations • Outdoor Unit silent mode — On/Off — Schedulable:Mon,Tue,Wed,Thu,Fri,Sat,Sun — Operation Mode:Cool,Dry,Fan,Heat,Auto(Dual or Single set — Start/Stop times in 5-minute increments point) — Silent Levels:Normal,Middle,Quiet — Set Temperature • Energy saving features: — Fan Speed — Automatic return to preset temperature setpoint if set point is — Daylight Savings Time(DST) changed from the remote controller after a preset time range • Vane setting:Auto,Step 1-5,Swing Cool preset temp:Cool,Dry,Auto-Cool • Louver:Off,Swing On Heat preset temp:Heat,Auto-Heat • Vent.(Lossnay):Off,Low,High Range of 30 to 120 minutes in 10-minute increments — Manual vane angle:No Setting,Step 1-5,Draft reduction,All outlet — Energy-saving Operation Schedule Draft reduction mode keeps the vane angle more horizontal than 0 Operation schedule the angle of Step 1 Four daily patterns with time periods in 5-minute increments and • Restriction energy-saving rate 0%to 90% — Set Temperature range limit o 7 day programming — Operation lock:On/Off,Mode,Set Temp,Vane • Night setback • High power — Starts Heat/Cool operation when room temperature exceeds — Operate at higher-than-normal capacity to bring room to set preset temperature range temperature quickly for up to 30 minutes —Adjustable time range in 5-minute increments • No Occupancy Auto-OFF • Main display — 3D i-See sensor required — Full:Shows all icons and values • On/Off timer — Basic:Limited to Mode,Set Temp.,Fan,Time&Day — Set On Time in 5-minute increments • Backlight Display — Set Off Time in 5-minute increments • Adjustable Contrast Level — Repeat daily — Language:English,French,Spanish,Italian,Portuguese,Greek, — Home screen display icon Turkish,Swedish • Auto-Off timer • CITYMULTI®Function setting —Automatically turns unit off after preset time • Filter maintenance notification —Time range of 30 to 240 minutes in 10-minute increments • Error code notification — Home screen display icon • Weekly timer — Set each day Monday through Sunday — 1 to 4 time periods per day in 5-minute increments — Set Mode:On/Off/Auto(Dual set point) — On/Off/Auto — Set Temperature *(All Capabilities are dependent on the model connected) Specifications are subject to change without notice. Copyright©2017 Mitsubishi Electric US, Inc. P AA-J SPECIFICATIONS AND DimENsoNs SPECIFICATIONS DIMENSIONS Product size In.(mm) I 4 3/4 x 4 3/4 x 3/4 120[4-3/4] 1913/4] (WxHxD) I(120x120x19) Net weight Lbs. (kg) 9/16(0.25) Rated power supply voltage 112 VDC (supplied from indoor units) Power W 10.3 consumption 4 Usage environment Temperature:0 to 40°C Huto104OOO O Humidity:30 to 90%RH (with no condensation) g I Panel PMMA (Front Material view) (Side view) Main body PC+ABS Sound Pressure dB(A) I<70[A-weighted sound Level pressure lever .1 Per Machinery Directive 2006/42/EC Notes: _ MITSI�BiSHI�. ELECTRIC COOLING & HEATING 1340 Satellite Boulevard,Suwanee,GA 30024 Toll a Free:800-433-4822 www.mehvac.com FORM#PAR-33MAA-J MA Remote Controller for CITYMULTI®- us 201706 Intertek Specifications are subject to change without notice. Copyright c,2017 Mitsubishi Electric US, Inc.