Loading...
Plans (31) Approved plans 47uOFFICE COPY PROJECT INFORMATION t`tart be on o#� s!!.'"-? ) � � OWNER JON SMALL RESIDENCE CONTRACTOR ELEMENTAL_ENERGY CITY OF TIGARD M1 x,_, 7470 SW CHERRY DR, TIGARD ,OR 97223 1339 SE 8TH AVE. PORTLAND,OR 97214 REVIEWED POR ODE COMPLIANCE JUN 2 5 ;9 CONTACT: LAUREL HAMILTON PHONE:(541)316-5785 Approved: ( CITY OF i':0117:10 BUILDING SINGLE FAMILY OTC: j � CHERRY DRIVE BUtLDo�:�w �:;+,r -�'1 DATA RESIDENTIAL _ SITE DETAILS COMPOSITION SHINGLE 2X4 PRESCRIPTIVE Permit#: APPLICABLE 2017 OESC&2014 OSSC TRUSSES @ 24"O.C., DOUGLAS FIR#2(TRUE IV t a019 L b Z-S B , CODES DIMENSION) Address: t ,.La'- IIIc I'&— 1 (E) RESIDENCE TILT: 17° SYSTEM HYUNDAI HIS-S290RG(BK) SOLAR MODULES AZIMUTH: 180° Suite #: (34)X290W=9.86 RG( @STC AREA OF ROOF(PLAN VIEW)=2,351 SF B - Bate. ,; -1 1 (34)M215 60 2LL S25 IG MICRO INVERTERS AREA OF NEW ARRAY=573 SF=24%OF ROOF - - - - AREA(ARRAY<25%OF ROOF AREA) rit" • - - - - MODULE HYUNDAI HIS-S29ORG(BK) •` 1.:A (E) METER CLIMATE DATA SOURCE: • " (EXTERIOR WALL) .44,7- SPECS SPECS (L)64.57"X(W)39.29"X(H) 1.38" !► 0"` r, WEIGHT=41.2 LBS PORTLAND/HILLSBORO,OR, USA, 45.53N, g!}.*s! ` , +! •a •Q (N)AC DISCONNECT/RSID 122.95 W • ., COMBINED WEIGHT OF ASHRAE EXTREME LOW: 6°C �' !+ ;• (EXTERIOR WALL) ",i',. MODULES AND RACKING:2.93 PSF<_4.5 PSF ASHRAE 48o HIGH:36°C • ,.• .4.•s• •' I WIND SPEED: 110 MPH(ASCE7.10) clAtg.4 (E) PANEL I 0 NUMBER OF ARRAYS PROPOSED: 2 RISK CATEGORY: II (INTERIOR WALL) WIND EXPOSURE CATEGORY: B pp :' ARRAY#1 DETAILS #OF MODULES: 18 TILT: 17° AZIMUTH: 180° I I 6��r GROUND SNOW LOAD:20 PSF ! ARRAY#2 DETAILS #OF MODULES: 16 TILT: 17° AZIMUTH: 180° I r I •� I • PROJECT NOTES I ^ ^ 1. PV SYSTEMS AND SUPPORTING STRUCTURE SHALL COMPLY WHERE THE SOLAR ARRAY EXCEEDS 25%AS MEASURED IN PLAN WITH REQUIREMENTS OF 2017 OESC&2014 OSSC. VIEW OF TOTAL ROOF AREA OF THE STRUCTURE,A MINIMUM OF 7/i, /./..,,ii/M' ///,/ ai ,-ri,7'i/iiiiri /a// ONE 36" UNOBSTRUCTED PATHWAY SHALL BE PROVIDED IN II I E 2. 3111.3.2-PV RACKING AND ATTACHMENTS SHALL BE UL 1703 ADDITION TO A MINIMUM 12" UNOBSTRUCTED ALONG EA. SIDE CERTIFIED. OF ANY HORIZONTAL RIDGE. t°17`1" 11111 II 111111 II 3. 3111.3.4 PV SYSTEM SHALL HAVE A FIRE CLASSIFICATION THAT 6. ROOF STRUCTURE IS CONVENTIONAL LIGHT FRAMED WOOD 0 ..r sk«• ❑ ea IS EQUAL TO OR GREATER THAN THE ROOF ASSEMBLY CONSTRUCTION WITH 2X4 PRESCRIPTIVE TRUSSES @ 24"O.C. • s 'IF • I REQUIRED BY OSSC SECTION 1505.1. REFER TO ALLOWABLE SPAN REQUIREMENTS IN TABLE 305.4.1. asv . /'� +q« •o !� •:• (N)ARRAY#1 `1 �� ,v": 4. 3111.4.3-3111.4.7-PV LAYOUT SHALL NOT RESTRICT EGRESS, 7. 3111.4.8.5.1 -DISCONNECTS,J-BOXES,COMBINER BOXES OR ♦ c.• a�•-+� • +�+♦vi'• ,i,..„, LIGHT VENTILATION,OR ROOF DRAINAGE REQUIREMENTS. GUTTERS SHALL NOT BE PLACED IN ANY REQUIRED PATHWAY `%'! :•VIM, (N)ARRAY#2 ,4 0`• OR CUTOUT. ��` �`+� M215 60 2LL S25 IG 0!},• Se So 11. 5. 3111.4.8.1 -GENERAL PATHWAY REQUIREMENTS: MICRO INVERTER ••. ... (UNDER MODULE) "•t•' .1. 4 •• 8. 3111.5.3.1 TOTAL SYSTEM WEIGHT SHALL NOT EXCEED 4.5 PSF. *$* • w• e.. I •! ♦. V.. 36"WIDE PATHWAY SHALL NOT BE REQUIRED ON STRUCTURES PV MODULES AND RACKING SHALL BE DIRECTLY ATTACHED TO I SAIV.. WITH A PV ARRAY AREA OF 1,000 SF OR LESS INSTALLED ON A ROOF FRAMING AS SHOWN IN PV-2.ATTACHMENT SPACING WILL N DRAWING LIST ROOF WITH A SLOPE THAT EXCEEDS 2:12 AND WITH AN BE 48"O.C.MAX, AND WHEN ATTACHMENT LOCATED WITHIN 3' INTERSECTING ADJACENT ROOF AND WHERE NO SECTION IS OF ROOF EDGE, HIP, EAVE, RIDGE SHALL ME24"O.C. MAX. � SITE PLAN PVI:SITE PLAN LARGER THAN 150 FEET MEASURED IN LENGTH OR WIDTH. W '� E PV-2: FRAMING PLAN- 9. 3111.5.4-MAX MODULE HEIGHT< 18"OFF ROOF SURFACE. I SCALE: 1/16"=1'-0" WHERE PV ARRAY DOES NOT EXCEED 25%AS MEASURED IN ' PV-3: ROOF PLAN PLAN VIEW OF TOTAL ROOF AREA OF A STRUCTURE,A MINIMUM s PV-4:THREE LINE DIAGRAM OF 12" UNOBSTRUCTED PATHWAY SHALL BE MAINTAINED ALONG PV-5: LABELS EACH SIDE OF ANY HORIZONTAL RIDGE. NOTE: `CHECK WITH CITY/COUNTY OR LAND SURVEYOR FOR ACCURATE PROPERTY LOCATE. APPENDIX: DATA SHEETS CONTRACTOR VALIDITY OF PERMIT JON SMALL RESIDENCE SITE PLAN ELEMENTAL ENERGY ►. THE tSSUANCE OF A PERMIT 1339 SE 8TH AVE. ELEMENTAL Residential Grid Interactive Solar Installation BASED ON CONSTRUCTION System AC Size @STC: 7.31 kW System DC Size @STC:8.86 kW Page: : 4,0h (34)HYUNDAI HIS-S290RG(BK) SOLAR MODULES PORTLAND,6GR8967214 NEPG ' 7470 SW CHERRY DR, TIGARD , OR 97223 DOCUMENTS AND OTHER (34)M215-60-2LL-525-IG MICRO INVERTERS PV-1 1 �tL�l� DATA SHALL NOT PREVENT Contractor#OR CCB#: 195141 THE CODE OFFICIAL FROM Drawn by: Project rmit S t39 Dao/2 DA Rev:Permit Set 6/20/2019 REQUIRING THE CORHI:C I ION OF ERRORS.ORSC 105.4 NOTES: ( PV MODULE i B 13'-4" PV-2 0 SUNMODO EZR MOUNT,TYP. ( O i j \, 2X4 PRESCRIPTIVE TRUSSES @ 24"0.C. .#/#,-. -' lam illigi Q C3 IRONRIDGE XR10 RAIL Atil'A‘ . _---_, ; e ... „:4,.,,,,,,, ,..,-- COMPOSITION r K4> RIDGE SHINGLE —1\ 6'-9" 0 EAVE PV MODULE CEILING JOISTS (6) 1'-0" SET BACK, TYP. 5J16"x4.5" LAG SCREW WITH 2 2.5 MIN. EMBEDMENT L __/ \_ \_ J B MOUNTING DETAIL Scale:NTS _ A A SECTION DETAIL PV-2 1/_ scale:3/16"= 1'-0" LINE OF FUTURE 17° ADDITION 29'-11" , n L. 29' 8., C/ T rrr�rrrr��rrrrrrrrrrrrr")fisi rrrrrrrrrr�rrr/rrrorrr/rrrrrrrr/rrrrrrr/�rrrrrO !!itarmo n :r msou "�'m orpai u" ! Marto nenn *7l/;w777/////////f/////4,„777/7/72,-.77/77/7/74777z7/ 7/727,7z77/7/777777/777 L.,.. L. 4 L_.1 m 1 {{ Oil °PO la� 0.J CJI if 'V. V ILA LP IJ Ill.. Cl U l.co 170 _ r-4T --. - --- -ter'- .-L J LL 4Q1 44— ---Eil- "�" • ° / / / / e w FRAMING PLAN I 29.-5" 26'-11" SCALE: 1/8"=1-0" (") CONTRACTOR JON SMALL RESIDENCE FRAMING PLAN ELEMENTAL ENERGY 1339 SE 8TH AVE. ELEMENTAL tvrEN ISystem AC Size @STC: 7.31 kW System DC Size @STC:9.86 kW Page: TAL Residential Grid Interactive Solar Installation PORTLAND, OR 97214 .u, E7470 SW CHERRY DR, TIGARD , OR 97223 (34)HYUNDAI HIS-S29ORG(BK) SOLAR MODULES Ph: (541)316-5786 ` ° ° Ph: (34)M215-60-2LL-S25-IG MICRO INVERTERS PV-2 Contractor#OR CCB#: 195141 Drawn by: Project#:19-1139 Date: DA Rev:Permit Set 6/20/2019 K)---C---1 KEYED NOTES: p v GENERAL NOTES: P 811 So: 1. CONDUIT IS DIAGRAMMATIC.FINAL 1011 O �O t� I INSTALLER. WS BE DETERMINED BY �� KD 1 (N) AC DISCONNECT o;,� . ��,�� D �/Q� O ��` ��i 2. SUNEYE SHOT S1 WAS COLLECTED IN THE r /} U 2 (N) M215-2LL-S25-IG MICRO INVERTER '••: ;.tom SPECIFIED LOCATIONS AND %1A1 F l.'s, , 9 • CORRESPONDS SHADE REPORTTOD JON SMALL RESIDENCE F ♦� +'�G/O� O (N) PV MODULE I 14114. ' ��+`�• /� (N) SOLADECK ON ROOF:36 `Z 111,11 •e�i� Ill Klilkilip 4:1111.4 \-1 illik ® (E) METER • K) • rA(E) SERVICE PANELz(5) �� �/ I I tst080 U 60 ticog ' %t'r 1.'rLorp O %6 "'mo frit 1111 "WA III 3/4" EMT OR BRANCH #2 (9 MODS) 0 ROMEX IN ATTIC I I ////r////////./07//////f�//(e// /��r/ /r/ „/„/„://r /� // J IL Jm m ILTJ '`/ r//////rr///rl//// /r/rr/r/ ////// //r//////// ri//rr�/r//r iirli --LI M -^I 1- -- f I I HYUNDAI HIS_S290RG(BK) _.___ ____ __., MODULE E 4, M M M M M M M .7 7 I H. MM MO . vaak In Sakai ao ♦ rI � il� 5i 0IIII O S,`*� ^�� , ri 8,1°8$ IQI O C illi�r a BRANCH# 1 (16 MODS) r 11�al a♦ Ide00 BRANCH#3 (9 MODS) 4 "lei o �� %(%l« I . 400ik ♦� IR:��.17"i C). 091. W ---"k".-- E ?ROOF PLAN ♦a Qz970 CALE: 1/8"=1°-0" S %r-C--Fe-1 r I , r tt` CONTRACTOR JON SMALL RESIDENCE ROOF PLAN ELEMENTAL ENERGY 4� ,-- -� t 1339 SE 8TH AVE ,F� System AC Size @ STC: 7.31 kW System DC Size @ STC:9.86 kW Page: ` w � Residential Grid Interactive Solar Installation _'. (34)HYUNDAI HIS-S29ORG(BK) SOLAR MODULES PORTLAND, OR 97214 , I. 1 7470 SW CHERRY DR, TIGARD , OR 97223 Ph: (541) 316-5786 Ph: (34)M215-60-2LL-S25-IG MICRO INVERTERS PV-3 Contractor#OR CCB#: 195141 Drawn by: Project*19-1139 Date: DA Rev:Permit Set 6/20/2019 , GENERAL NOTES: METER 1. CONTRACTOR RESPONSIBLE FOR COMPLYING WITH ENPHASE ENVOY O I I ALL LOCAL OR NATIONAL CODE REQUIREMENTS AND EXISTING 120V EQUIPMENT INSTALLATION INSTRUCTIONS. A OUTLET FREE AIR ENPHASE ET-10 CABLE(TYP.) BLACK-L1 2. SEE PV-5 FOR LABELING REQUIREMENTS 0 IC I RED-L2 WHITE-N PATCH CABLE TO GREEN-GND NETWORK ROUTER BRANCH CIRCUIT#1 oO e o • • • ____________ (16)HYUNDAI HIS-S29ORG(BK) .))1MODULES (16)MICRO-INVERTERS ! I I I I I III@ 240V VAC SOLADECK, "__ '"__ NEMA-3R, LAY IN LUG 111111 --- 3 120/240V,1� \ -- - r R UTILITY NON-FUSED AC RAIL DISCONNECT20A II ENPHASE M215-60-2LL-S25-IG 60A,240V,2-POLE ,—d 3 4 i=1 A F-7 ) = II 20A -_ _... _...40A --. BRANCH CIRCUIT#2 :::1 EL 1 , < -INVERT < <©OOUND ..—....= _ EXISTING AC DISTRIBUTION PANEL — LAY IN LUG 120/240V,1P,3W I I 200A PANEL \--3/4"EMT OR EQUIVALENT: 200A MAIN BREAKER RAIL (3)#8 AWG THWN-2 CONDUCTORS II (1)#10 AWG THWN-2 GROUND ENPHASE M215-60-2LL-S25-IG I t. �- ; 11 '�`\ m,.,5.. — .� _ __.. � _ _ 3/4"EMT/ROMEX THWN-2 --_. (2)#12 AWG THWN-2 CONDUCTORS BRANCH TERMINATOR MODULE SPECS (1)#12 AWG THWN-2 NEUTRAL E-TERM-10(TYP.) — INVERTER SPECS (1)#12 AWG THWN-2 GROUND MODULE MAKE HYUNDAI ENPHASE MODEL M215-60-2LL-S25-IG / BRANCH CIRCUIT#3 1 MODULE MODEL MIS-S29ORG(BK) ' (9)HYUNDAI HIS-S29ORG(BK) MAX.POWER Pmax 215 WNM • • • MODULES MAX,POWER Pmax 290 W MAX.INPUT VOLTAGE 48 V (9)MICRO-INVERTERS OPEN CIRCUIT VOLTAGE Voc 38.8 VII. '` @ 240V VAC HIS-S29ORG(BK)Voc @ 39.8 V ■ I♦ II MAX.POWER POINT Vmp 32 A 16,88°C -- — SHORT CIRCUIT CURRENT[so 9.7 A 39.8V<48V YES LAY IN LUG MAX.POWER POINT Imp 9.1 A OUTPUT CURRENT 0.9 A ! RAIL Voc TEMP.COEFF. -0.30%/°C OUTPUT VOLTAGE 240 V, 1.4) —. II ENPHASE M215-60-2LL-S25-IG Pmax TEMP.COEFF. -0.44%/°C DC/AC RATIO 1.35 II VOLTAGE DROP CALCULATIONS JUNCTION BOX(TYP,) #6 BARE CU(TYP.) WIRE RUN #OF MODS V(VOLTS) I(AMPS) L(FT) VD" VD(%) WIRE SIZE RACEWAY 3/4"EMT/ROMEX THWN-2 BRANCH#1 TO SOLADECK 16 - 240V 14A 70 1.83V 0.77% (2)#12 AWG THWN-2 CONDUCTORS 12 AWG FREE AIR (1)#12 AWG THWN-2 NEUTRAL BRANCH#2 TO J-BOX 9 240V 8A 50 0.57V 0.24% 12 AWG FREE AIR (1)#12 AWG THWN-2 GROUND BRANCH#3 TO J-BOX 9 240V 8A 14 0.45V 0.19% 12 AWG 3/4"EMT/ROMEX BRANCH#2 J-BOX TO SOLADECK 9 240V 8A 12 0.38V 0.16% 12 AWG 3/4"EMT/ROMEX BRANCH#3 J-BOX TO SOLADECK 9 240V 8A 14 0.45V" 0.19% 12 AWG '3/4"EMT/ROMEX SOLADECK TO PV BREAKER 34 240V 31 A 40 1.90V 0.79% 8 AWG 3/4"EMT CALCULATIONS NOTES: MAX VOLTAGE DROP:1.56% 'WIRE SIZES INCLUDE DE-RATING FACTORS SUCH AS AMBIENT TEMPERATURE AND MORE THAN 3 CURRENT CARRYING CONDUCTORS IN CONDUIT. "BRANCH CABLE VOLTAGE DROP AND LENGTH DATA FROM MICRO INVERTER MANUFACTURER.LENGTH FROM BRANCH TO SOLADECK INCLUDED. —*WHERE AC UNGROUNDED CONDUCTORS ARE INCREASED IN SIZE,EGC SHALL BE INCREASED IN SIZE PROPORTIONATELY ACCORDING TO THE _CIRCULAR MIL AREA OF THE UNGROUNDED CONDUCTORS. CONTRACTOR JON SMALL RESIDENCE THREE LINE DIAGRAM ELEMENTAL ENERGY 1339 SE 8TH AVE, ELEMENTAL Residential Grid Interactive Solar Installation System AC Size @STC: 7.31 kW System DC Size @STC:9.86 kW Page: °' 7470 SW CHERRY DR, TIGARD , OR 97223 (34)HYUNDAI HIS S290RG(BK) SOLAR MODULES PORTLAND, OR 97214 ENERG a (34)M215-60-2LL-S25-IG MICRO INVERTERS PV-4 �, a� Ph: Ph: (541)316-5786 Drawn by: Project#:19-1139 Date: Contractor#OR CCB#: 195141 DA Rev:Permit Set 6/20/2019