Report TRANE Submittal Prepared For: Date:May 30, 2019 JUN - 3 2019 Oregon Heating Sold To: Job Name: Fanno Creek-Goodlife TI Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 1 Variable Air Volume Single Duct Terminal Units The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed between submittal generation and equipment release,the product Kyle Wolf-Trane U.S. Inc. performance and submittal data will need to be verified. It is the customer's responsibility to obtain such verification. 7257 SW Kable Lane Portland, OR 97224-7181 Phone: (503)620-8031 Cell: (503)828-6788 Fax: (503)639-1454 J:IJOBSI124177439131Fanno Creek-Goodlife TI-submittal 02.doc Fanno Creek-Goodlife TI May 30,2019 Tag Data-Variable Air Volume Single Duct Terminal Units(Qty: 1) Item Tag(s) Qty Description Model Number Al VAV-1 1 Variable Air Volume Single Duct Terminal VCEF08 Product Data-Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s):VAV-1 Single duct with electric heat 8"inlet size,900 cfm (203mm inlet, 425 Vs) Matte faced insulation - 1/2"(13 mm) DDC with on/off electric heat control (Verify Controls Communication) Standard actuator 277/24 volt transformer Disconnect switch Power Fuse 277 volt, 1 phase Electric heater kW-3.0 Stage-1 24vac magnetic contactors 1 DDC sensor only(Fld) FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 2 of 10 Others Fanno Creek-Goodlife TI May 30,2019 Mechanical Specifications-Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s): VAV-1 General Unit Information The unit casing is comprised of 22 gauge galvanized steel. Outlet connection is slip and drive. Agency Listing-The unit is UL and Canadian UL listed as a room air terminal unit. UL Control#9N65. All Trane terminal units are AHRI 880-98 certified. General Unit Clearance Allow adequate clearance on control box side of unit to meet NEC. A minimum of one and one half duct diameters of straight duct work,upstream of the air inlet connection,must be present for optimum airflow measurement performance. Upstream duct work should be the same diameter as the primary inlet connection.Allow access to the bottom of unit if Optional Bottom Access Door is selected. 1/2" Matte-Faced Insulation The interior surface of the unit casing is acoustically and thermally lined with 1/2" 1.50 lb.cu.ft. [24.00 kg./cu. m.] composite density glass fiber with 4.0 lb.cu.ft. [64 kg./cu. m.]high density facing. The insulation is UL listed and meets NFPA-90A and UL 181 standards. The insulation R-value is 1.9.All cut edges of insulation are completely encapsulated in metal to prevent erosion. Air Valve Size-08 Air Valve is 900.0 cfm 8"inlet. Air Valve Round The air inlet connection is an 18 gauge galvanized steel cylinder sized to fit standard round duct.A multiple point, averaging flow sensing ring is provided with balancing taps for measuring within +/-5%of unit cataloged airflow. An airflow versus pressure differential calibration chart is provided. The damper blade is constructed of a closed cell foam seal mechanically locked between two 22 gauge galvanized steel disks. The damper blade assembly is connected through a cast zinc stub axle and shaft supported by self lubricating bearings. The shaft is cast with a damper position indicator. The valve assembly includes a mechanical stop to prevent over stroking.At 4.0"w.g. air valve leakage does not exceed 1%of cataloged airflow. Power Disconnect Switch (for VCEF) A factory provided interlocking door disconnect switch located on the electric heater control panel. Line Fuse-VCEF For VCEF units,fuses provided on all energized lines of incoming power to interrupt circuit in overcurrent conditions. Slip& Drive Connection A slip and drive connection has two straight flanges on the top and bottom, and two drive connections on the left and right sides. This is a standard option on all VAV single duct terminal units. Electric Heat Coil Factory provided and mounted resistance open-coil type heater with airflow switch, a disc-type automatic pilot duty thermal primary cutoff, and manually resettable pilot-duty thermal secondary cutoff with associated backup contactor. Heater element material is type C nickel-chromium alloy. The heater terminal box is provided with 7/8"knockouts for customer power supply. Terminal connections are plated steel with ceramic insulators. Unit is Flippable for both Left and Right hand control access, except with mercury contactor option. [— Magnetic-Contactor An electric heater 24 volt contact for use with Direct Digital Control(D.D.C.)or Analog Electronic VAV Controls. Electric Heat Transformer A 50VA or 75VA class 2 transformer will be an integral component of the heater control panel dependent on unit load requirements to provide 24 VAC for controls. System Communications The controller is designed to send and receive data from a Tracer Summit or other Trane Controllers, or a VariTrac Central Control Panel. Current unit status conditions and set points may be monitored and/or edited via this data communication feature. The network type is a twisted wire pair serial communication. Override Commands The following override commands may be received by the Unit Control Module(U.C.M.)from the Tracer System. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 3 of 10 Others Fanno Creek-Goodlife TI May 30,2019 Control Mode,Action,Offset&Commands * Control Mode-Occupied or Unoccupied * Control Action -Heating or Cooling * Control Offset-Enabling Control Offset will increase the cooling temperature setpoint and decrease the heating temperature setpoint by a control offset value. * Drive damper fully open. * Drive damper fully closed. * Drive damper to maximum airflow setpoint. * Drive damper to minimum airflow setpoint. * Disable unit heat. * Reset-Enabling the reset function forces the controller and the flow sensor to recalibrate. Editable Set points and Functions Occupied and unoccupied cooling temperature set point 30.0 F-100.0 F. Occupied and unoccupied heating temperature set point 30.0 F-100.0 F. Maximum flow set point(10-100%of unit equivalent cataloged airflow) Minimum heating and cooling flow set point(0, 10-100%of unit equivalent cataloged airflow) Cooling set point low and high limit Low 30.0 F-100.0 F. High 30.0 F-102.0 F. Heating set point high and low limit 30.0 F-100.0 F. Hot water valve drive time Air valve drive time Direct Digital Controller The microprocessor based terminal unit controller provides accurate,pressure independent control through the use of a proportional integral control algorithm and direct digital control technology. The controller monitors zone temperature set points,zone temperature and its rate of change,and valve airflow using a differential pressure signal. Optionally,the controller can monitor either supply duct air temperature or CO2 concentration via appropriate sensors.The controller is provided in an enclosure with 7/8"knockouts for remote control wiring. A Trane zone sensor is required. D.D.C. Floating Point Actuator Trane 3 wire,(open,close,common)26GA when 6-pos amp connector is used for Tracer UC210,W550,or VAV UCM, otherwise 18GA wires are used. 3.4 VA, 1.7W, 24 VAC, 50/60 Hz. Quarter turn control actuator with linkage release button.Actuator has a constant drive rate independent of load, a rated torque of 35 in-Ib, a 90-second drive time and is non-spring return. Travel is terminated by end stops at fully opened and closed positions.An integral magnetic clutch eliminates motor stall. An integral 3 screw terminal block is provided for field wiring. Operating temperature 32.0 F to 125.0 F. DDC Controls Option DD04, DD14, DD44& DD74 Basic Operation: On/Off Staged Electric Heat(Normally Open Outputs)(DDC/UCM) A voltage signal from the zone sensor indicates the zone temperature is used by the unit controller to determine an error from the set point. This error, as well as primary flow differential pressure, is used to determine damper position within minimum and maximum cooling airflow set points. As the zone temperature drops to the heating set point, primary airflow is controlled to minimum heating flow set point. Staged electric heat is energized. Fan Control Offset-determines at what point a parallel fan is energized. This can be a function of temperature(degrees above heating set point)or primary airflow Series Fan Configuration-allows series fan powered to shut off fan and close air valve when unit is unoccupied. Fan will operate in unoccupied mode if reheat is active. Local heating flow set point enable/disable and set point Analog input mode-auxiliary temperature sensor or CO2 detector Binary input mode-generic or occupancy detector Zone temperature, auxiliarytemperature, and zone set point calibration corrections(± 10 ° F)[± -12°C] Flow measurement calibration correction (60-150%) Additional Status Information Available FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 4 of 10 Others , Fanno Creek-Goodlife TI May 30,2019 Active cooling set point Active heating set point Current unit primary airflow Current zone temperature Reheat status(on/off) Fan status(on/off) Calibration status(calibrating/not calibrating) DDC Sequence of Operation The unit controller continuously monitors the zone temperature against its set point and varies the primary airflow as required to meet zone set points. Airflow is limited by minimum and maximum airflow set points. DDC Zone Sensor Only This electronic device utilizes a thermistor to vary the voltage output in response to changes in the zone temperature. Wiring to the U.C.M.controls must be 18 to 22 awg.shielded twisted pair wiring. The set point adjustment range is 50.0 F -88.0 F. This is a sensor only with a 2 wire connection. An optional communications jack is available which snaps into the enclosure backplate. Auxiliary air temperature(if unit has auxiliary temperature sensor) Not available if CO2 sensor used. CO2 concentration(if unit has CO2 sensor) Not available if auxiliary temperature sensor used. Ventilation ratio BIP state Failure indicators • Temperature sensor failures • Flow Sensor failure • Local zone sensor set point failure FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 5 of 10 Others Fanno Creek-Goodlife TI May 30,2019 Unit Dimensions-Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s): VAV-1 2v4"— c 8" > 4" " n AIR VALVE AIR FLOW 1\[/' n — jL! HEATER VII°421/2" 31" Customer Notes 1.Air Inlet is centered in unit front panel. y 2.Slip&Drive discharge outlet standard. A I I 3.Minimum of 1.5 times duct diameter of straight duct 1" J at inlet for proper flow reading. 4.For electric heater access,side TOP VIEWF 181/2" SLIP&DRIVE hinged door must have minimum distance CONNECTION Per NEC Or local Coda. 5.Allow 48"of straight duct downstream of unit before first runout&inside of the duct should be equal discharge size.(A&B) 6.Left-hand orientation shown.(Facing discharge) Unit can be flipped to right-hand orientation n 10" 11 1/2" Approximate V y Dry Weight 38.0 Ib 11 Weights reflected may vary BACK VIEW F— 6" 121/2 ±5.0 lb based upon options selected. FLD=Furnished by Trane U S.Inc./Installed by Equipment Submittal Page 6 of 10 Others Fanno Creek-Goodlife TI May 30,2019 Accessory-Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s):VAV-1 aim• . I nm• Customer Notes: 1. Zone Sensor only. 2. Optional communications jack available. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 7 of 10 Others • • Fanno Creek-Goodlife TI May 30,2019 Field Wiring -Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s):VAV-1 HEATER STAGE 24VAC 60HZ CONTACTOR(S) OPTIONAL NEC CLASS-2 I I CONTROL CIRCUIT r 1 TRANSFORMER TB1-1 T62A TB3J TB3-1 I l I I LOAD=12VA ®® I I I I (WITHOUT HEAT) TBI-2 TB2-5 TB3-2 -___ __ • 0000000 11 10 7 S 3 2 1 DIGITAL DISPLAY ZONE SENSOR m r } W/COMM.JACK REMOTE MTD. re > o S r QQ _ ✓ -I PING HOT OPTIONAL FIELD INSTALLED L DIGITAL DISPLAY ZONE SENSOR J PIN 4 OPEN SPRING PIN 3 CLOSE gCTUATOR RETURN r TB2-6 T831 TB7 2 GND TB2-5 TB3-2 TB33-3 L SPRING RETURN ACTUATOR J 0 011CJ 0 0 2(.)1(-)J 3 2 1 ✓ -I ZONE SENSOR PIN B HOT 1rn,1III r J1 0 0 0 0 op 1 y W/COMM.JACK �J QL ACT _�_ REMOTE MTD. U (PIN 4 OPEN STANDARD 1.J BIP ONE 24V Q Q 3 CLOSE ACTUATOR C ADDRESS D.D.C.W.C.M. OPTIONAL FIELD •I LL INSTALLED ZONE SENSOR SWITCH CONTROL BOARD o r , STANDARD ACTUATOR IIDIDII -. L J i o 24V (TBI-1)24V CO2 (TB36)GND pi pi pp f� TEL GRN m m ci pi �N SENSOR GND 0 ��m- ���— ❑ ❑ H�H� �� OUT V (TB3-5)A/CO2 ZONE GND SET NCO2 GND OPTIONAL FIELD INSTALLED L CO2 SENSOR J r TB3-5 1 r TB36 0 0 II SHIELDEDTPAIR COMMUNICATIONS WIRING OPTIONAL FACTORY INSTALLED OPTIONAL WIRELESSL AUX TEMP SENSOR J r -T BL OPTIONAL r l FACTORY R(HOT)_____ IV (TBt-1)24VAC INSTALLED WIRELESS OROMMON___(TB/-1)BIP CR(NC CONTACT)_(el-1)24VAC 24VACBL Y I BKVRETURJ___ V (TBI-2)GND -NOT CONNECTED - OPTIONAL FIELD INSTALLED Q �' L OCCUPANCY SENSOR , ®WARNING GND 24V W550 Board HAZARDOUS VOLTAGE! L J DISCONNECT ALL ELECTRIC POWER NOTE: INCLUDING REMOTE DISCONNECTS BEFORE SERVICING. 1. FACTORY WIRING FAILURE TO DISCONNECT POWER BEFORE SERVICING CAN CAUSE FIELD WIRING SEVERE PERSONAL INJURY OR DEATH. OPTIONAL OR ALTERNATE WIRING ®CAUTION DEE COPPER CONDUCTORS ONLY! _ ZONE SENSOR TERMINALS 1(-)AND 2(+)REQUIRE SHIELDED TWISTEDPAIR WIRING FOR UNIT TERMINALS ARE NOT DESIGNED COMMUNICATIONS JACK EQUIPPED ZONE SENSOR OPTION. TO ACCEPT OTHER TYPES OF CONDUCTORS. Q NO ADDITIONAL WIRING REQUIRED FOR NIGHT SETBACK OVERRIDE(ON/CANCEL). FAILURE TO DO SO MAY CAUSE DAMAGE TO THE EQUIPMENT. ZONE SENSOR TERMINALS 6 AND 7 REQUIRE SHIELDED TWISTED PAIR WIRING FOR OPTIONAL USE OF COMMUNICATIONS JACK. • FLD.=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 8 of 10 Others Fanno Creek-Goodlife TI May 30,2019 Field Wiring -Variable Air Volume Single Duct Terminal Units Item: Al Qty: 1 Tag(s):VAV-1 277 Volt,1 Phase L1 N I I I I I I I I I I ri 4,7 Heater Controls Wiring FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 9 of 10 Others P'anno Creek-Goodlife TI May 30,2019 Field Installed Options-Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family-Variable Air Volume Single Duct Terminal Units Item Tag(s) Qty Description Model Number • Al VAV-1 1 Variable Air Volume Single Duct Terminal VCEF08 • Field Installed Option Description Part/Ordering Number DDC sensor only X1 351 1 52801 0 FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 10 of 10 Others