Loading...
Plans (24) OFFICE COPY RECEIVED JUN 2 0 2019 CITY OF TIGARD BUILDING DIVISION I ,.... 1111 ' L. li.' ,I. It ,--i - 1 . . , . ..,,.. .. ..._...___. __ ....._ _.....—_— — i ,.. i 4.- 1 r 4 g , . ..., _ , .%,k $- o 1 i - ,'-.---,.,,‘ , ' — 1 K,,, ,.: . A it,,,,,"#-A. g- '4 1 r --,g,..4 - ' '-A "-4; 4 *14 . ; ; ' r. '''','", 41 k, 3' ' 't, .," ‘ 5 4 .,... .*:,%5,,-,.-'t .2:54 .,5,•Vo....-A,:.' 44,' ' '.,.a" -.5'1 i5 -':'; X4'*'' i )f,'''': '' '::*:'''' e,tit .., g Y r f q-''.4 . , ., ,. -,...i..4'" 4,-67-'" 44,4:4,' ,',.`, -',. , ... . .,,.,...i.,se#44."‘4.„itzi ..littit, IA- VV ; 1, `'''• 4 /f'44,1,4Y w - ? i , 0 1 ' I t,,,.,4-:' .t . ..,,,, ,4 74 1 t '' *m- i t — -------'*--'-'-'" --- Ar''' ' — , 4 ' .,. _,.. , CITY OP TIGARD REVIEWED FOR CODE COMPLIANCE OiuTANYNCCOOE N OF FT PRA LIEPCRETRMI OMNIITT Approved: I . VTBAHAESLEI SDDS OTC: ._ I I , R EDT DQHA:JET ACI RCUSI ONMHDGAEENLT OFFICIALLHT SNE OAc 0TN DPR RROEEPTvc Ti-RiiivtoRTN Permit#: (1 Address: ( 9 40 s e, ,,„c.„1 1.. t,y.j_....r...j Suite#: .,-- By: 7_I _ ) 9 OF ERRORS.°SSC 1mm 4 Al WEIIfficLAIN EvergreenTM www.weir-mclain.com'sECEIVEIHIGH-EFFICIENCY CONDENSING BOILER • Water I Natural/Propane Gas 1220-399 MBH 13 Sizes JUN �' 2019 Direct Vent 195% AFUE* AIIIIII _ ,.31,-. '‘I aA V41.i... ,,,,„ ,,'„,, 1 i i ®wen mtuur Ir ., 1 EvewreeTM ., tffi ',� 111 Easy heat, Effortless comfort ,i;:;,,:71,,,, x 4610,:x;,„: DURABLE FLEXIBLE E S Y L EA Stainless steel fire tube 24-zone capacity Control presets heat exchanger Floor stancing/wall mount Accessible parts ''' .,,,,,,,\\-, : '.., )...' ,..',',,-.1i -... "'- - 7 r�• .. 'C,.r. s d'...,may a T 4 e l -n 111 } .r , a ' ..' ""*w_ aye r ” __- vergreen 399 rating.s canhustion efficiency `+� ,_.. `� .,,,.,,._ �_14...,—...,,,.. . ,. �..4' rad` - - • I., 1. •• am APPLICATIONS1 The new EvergreenTM boiler extends comfort It's everything you want in heating: quiet levels to every area of your property for the operation, aesthetically pleasing design, floor long run. The Evergreen is perfect for light standing or wall mount options, environmental commercial or large residential applications sustainability with Low NOx, heating comfort and single or multi-unit installations with with lower utility bills* and more. ZoneStackingTM up to 24 programmable zones. 410 � � : ti �i ! RESIDENTIAL ... rX-- •,., ,.',,h'4'' .`I'', li ..h4;',4e.'' *9177. i` ti r� ' ' ��' `---«_ ., a : Stay effortlessly comfortable in any home�4 f � environment with the new Evergreen boiler. ' � ,7 . . `� - - The quiet operation of the Evergreen further LL enhances the sense of "invisible" heat, from 4a- .- G ' multiple in-home zones to pool heating. ` ♦ -n i ■ The Evergreen's sleek, modern design adds value to the _-- '' home or property. ■ Ease of programmability makes achieving comfort simple. 'il Itl?` ' __- , ??!.:7'!":", • For the homeowner who wants heating comfort 0 x .. % 6 f . while maintaining lower utility bills and reducing their r , e :. carbon footprint, the Evergreen 220 and 299 boilers x`ins ,, , are recognized as Most Efficient by Energy Star` 2015 ' - 1-71 i inn: mug _____.::1711.'-. al standards with an AFUE rating of 95%. This could qualify Ir .. [..,,irl the homeowner for available local utility rebates, if available. The Evergreen provides a Low NOx of< 20 PPM, � ^ which adds to the greener environment sustainability. • The high performance of the Evergreen boiler works seamlessly with the efficient and durable AHRI Certified"' Weil-McLain AquaPlus` Indirect Fired Water Heaters, ', t# available in five sizes to meet demanding hot water 1 'i a y,� applications. k 3 Y� 'J` �4kA�. 66-4 I f� • %z, fir: ` ... # t-+-'7 . q Federal tax credit available in qualifying areas ° � `� 4 h' ENERGYSYAR i Abe, ; e.;•'.' . III olo z, lE Y Limirt� 1 : n . ,... , - - -------------„,„ : . ‘-,,,,i,..„_,, ,. ,,,...„------ ,. ZONESTACKING .,_ 1,, Enables all zone capabilities i' o of each individual boiler when - r "" ri ! , ;.t * connected on a cascaded ii- ` ROL network of boilers. With the i • Evergreen boiler, the number 10°l0 �- 1 "� of programmable zones is three 10% times the number of boilers on 10%titthe network, up to eight boilers. 10% COMMERCIAL Familiar interface - innovative technology ■ For the residential and light commercial customer who requires a multiple boiler setup, the Evergreen provides ZoneStacking - 24 zone capability without As our technology has advanced to create an additional external 3rd party control. smoother, more efficient operations, we've kept • ZoneStacking reduces the installation costs and the interface of the Evergreen boiler familiar, time while increasing reliability. With this advanced control feature, the Evergreen boiler maintains simple to use and easy to learn. optimal efficiency through lead-lag rotation and balanced heat loading. EASE OF INSTALLATION EASE OF MAINTENANCE • Setup wizard efficiently guides the installer through a ■ Large, accessible panels for quick and easy single or multiple boiler installation in minutes maintenance checks ■ For the contractor, installer and/or service provider, ■ Interactive diagnostic capability provides a snapshot the Evergreen has an easy to understand graphical of the past and current operation parameters user Interface and makes programming and ■ Reliable operation of the complete heating system monitoring operations simple including radiant elements • Wiring diagrams provided are clear and easily ■ Sentinel X100' inhibitor is included with the boiler accessible to ensure the water chemistry is optimal for heating system efficiency EASE OF USE ■ Ability to control multiple boilers with lead-lag capability without an external device • Interactive diagnostic capability ■ Reliable operation IS Easy to understand and monitor controls • Effortless heating and comfort in all zones w - _ -, °_ -'R. ' " "`' �" - �. ' - ' E.) E.0 THREE SELECTABLE I SEQUENCING MODES TO CHOOSE FROM a Series Sequencing Quickest- boiler goes to 100% before another boiler is turned ivILILTIPLE output is achieved more quickly with less total . , . , Nbci G Nburner hours ■ Parallel Sequencing Efficiency and speed- based on Base Rate High; The flexibility of the Evergreen Hybrid mode between boiler system reduces setup Smart and Series modes; boilers will go to user time and keeps costs down. programmed base rate high before turning on the next boiler SERIES Sequencing PARALLEL Sequencing SMART Sequencing • smartsequencingrM �_ .. --� Most efficient- maximizes Higher Part-Load Efficiency,.. ...1111.- _ Quicker Boiler Response —� turningon part-loadefficiency .1111...... . P by oas many �% _ - _ 1�X _ - _ boilers as possible ' { so% in� a ` ,,, munomit ..,„ 55% '1 PROGRAMMABLE ,, i IR It d t PREFERENCES FOR °,, 3001 82 0.10,3 � 3 .11 0x 2 8031.13 °� , 801.12 904x3 MULTIPLE BOILER 0x STAGE I-Lead boiler modulates up to a maximum ofbe- STAGE 1-Lead boiler modulates up to a maximum of Base STAGE I-Lead boiler modulates uptoalow firing rate before SETUPS fore turning on the next boiler in the sequence.The STABILIZE Rate High before turning on the next boiler in the sequence. mmingonthenextboiler inthe sequence.The STABILIZE TIME TIME allows time for the boilers to modulate to meet system The STABILIZE TIME allows time for the boilers to modulate allows time for the boilers to modulate to meet system demand demand before turning on additional boilers. to meet system demand before turning on additional boilers. before turning on additional boilers. ■ Multiple Boiler 100% 6- --- - — 100% Sequencing c., " ' sx% f ,_£ '..'�:` sx7. - User selects what l L -. P I point one boiler stops 50 lit �` 50 I ' , modulating before u% • � uX d i , , :. 2SF p x 95Ea.;-Lo�w ." turning on another boiler �% a Lead Lag Rotation 001011 90012 000.3 001.11 03.2 0010,3 00011 90002 001013 User selects which boiler STAGE 2-Boiler#2 in sequence ignites and both boilers STAGE 2-Boiler#2 in sequence ignites and both boilers STAGE 2-Boiler#2 in sequence ignites andbothboilersmodu- turns on first and can modulate to so their combined energy outputmatches the energy modulate to so their comb ined energyoutputmatches the energy late to BASE RATE LOW.After a short MOD DELAYliME,the output of Boiler#1 at 100%.After a short MOD DELAY TIME, output of Boder#1 at Base Rate High.After a short MOD DELAY boilers will be released to modulate. choose based on burner the boilers will be released to modulate. TIME,the boilers will be released to modulate. hours,fixed rotation or ,ao10 i - - ,tux — .. — 100% l}� ..1 — , no rotation 75, ' II .� � 5% um' • Input/Output Options ami 50% ill Input and outputs can be x,% i , - 25% 1 �i ' z5% I �. used for every boiler with d j 0.i 4 , `.d 5.4 .. J0 �000xn BASE0Om Low.an% '.d .. 0% - - a% up to 24 capable input/ 000x, 80x2 Bo. Bole,, 150lar2 moss BoW1 800,2 80Mr3 output pairs STAGE 3-Both boilers modulate uptoamaximum of100%be- STAGE 3-Both boilers modulate up to a maximum of Base STAGE 3-Both boilers modulate up to a low firing rate before a Redundant Sensors fore turning on the next boiler in the sequence.The STABILIZE Rate High before turning on the next boiler in the sequence. turningonthe nextboilerinthesequence.The STABILIZETIME TIME allows time for the boilers to modulate to meet system The STABILIZE TIME allows time for the boilers to modulate allows time for the boilers to modulate tomeet system demand If one system supply or demand before turning on additional boilers. to meet system demand before turning onadditional boilers. before turning on additional boilers. outdoor temperature ,00% 25% 100% 4'..'7 — — sensor fails, here are m �: 5X 5X r l backups. If backups fail, C 2 t the system can still run 1 a -,1mit i on a special safety mode 25% *t`� oRA� 20%2054 I:,i ■ Auxiliary Output 0% O% Flexibility 9001, 00,2 900x5 Baby, 801.12 8010,3 001101, 900x2 800013 - -----u___-- - Ability to control system STAGE 4-Boiler#3 in sequence ignites and then all boilers STAGE 4-Boiler#3 in sequence ignites and then all boilers STAGE 4-Boiler#3 in sequence ignites and then all boilers modulate to so their combined energyoutput matches the energy modulatetosotheircombinedenergyoutputmazchestheenergy modulate to BASE RATE LOW After a short MOD DELAY TIME, circulators, combustion output of Boilers#1 and#2 at 100%.After a short MOD DELAY outputofBoilers#land#2 a[Base Rate High.After a short MOD the boilers will be released to modulate. air dampers and/or TIME,the boilers will be released to modulate. DELAY TIME,the boilers will be released to modulate. —_.-- - other auxiliary system components 75% •ti ]5% r ]5% r SOX ,1 ' 50% 4 IIIMi 1111111 + L Y '. vic It I * et BeW14 801x2 ....., - 0044,.1 00.2 80.3 800x1 ft.2 901x3 ,..• � .-.� ": STAGES-After allavailableboilersarefiring,boilersarerelease STAGE5-After all available boilers arefiring,boilersarerelease STAGES-After all available boilers arefiring,boilersarerelease " e yM.47 " -°'�Kl` to modulate up to 100%of rate- to modulate up to 100%of rate. to modulate up to 100%of rate. SIMPLE INTERFACE - C LCULATINS Straightforward, user-friendly design with advanced technology. What's happening behind the scenes? Complex calculations of the required energy A to meet system demands is distributed ; across all the boilers in the network. } 4 1 111 °I' S i., System maximizes user's comfort by 43 simultaneously meeting as many system demands as possible: When there are • multiple requests on a cascaded boiler , system, the control satisfies both local and - network heating demands. va , .." Setup is easy. The built-in wizard asks direct questions on setup, making customization easy and straightforward. Contextual help is also available on screen. Visual Communication Screens EM: m WEt - 4 ,„,‘,,,,,,,,,.-7,,,,,,%; WEIL-mcLAIN 14 "yw � -- vv ' rlHH ,MMZZ MM/ DD/ YY ,II ..a: , BOILER ID: EVD### BOILER ID* Elip#04O + VG MODULATION : MODULATION . - I I BAR TEMP:### ° F BLR TEMP:###" P5" SYS TEMP:### ° F SYS T EMP;### F' STATUS : STANDBY STATUS PREPUFGE ### EN ;h.s,,% DEMAND DEMAND 1 2 3 ,,t:' ` •`` NEXT► — t1 .X I STANDBY SPACE HEATING DHW HEATING CHECK SYSTEM E51� �+I9R CERTIFIED DOE I�gEra` m 4,, FR '�R H 'Model 220 and 299 only FEATURES . BOILER JACKET ASSEMBLY ■ Stainless steel fire-tube heat exchanger ■ Easy maintenance with top access panel ■ Non-metallic heat exchanger base ■ Fully removable jacket front door • Floor standing or wall-mount option with kit a Adjustable boiler legs ■ Natural or LP gas ■ On/off power switch ■ Negative regulated combustion a Line voltage service receptacle ■ 10 to 1 turndown ratio ■ Mounting bracket ready for wall-mount kit a Boiler circulator ■ Condensate trap a Propane conversion kit ■ Low water cut-off OPTIONAL EQUIPMENT ■ Sentinel X100 inhibitor and test kit ■ Wall-mount kit ■ Low NOx< 20 PPM ■ Concentric vent kit • Condensate neutralizer kit CONTROL FEATURES • Sidewall vent/air termination kit ■ Easy installation with Setup Wizard ■ Maintenance kits ■ Zone and/or priority based control ■ Three thermostat Inputs __ _ ■ Outdoor reset for each priority -- - _ ■ Rate adjustable per priority %11- _ ■ 0-10V input(modulation or setpoint) i 1 � a � I= la ■ Four total outputs ` ' - 1 dedicated boiler circulator output ' ,, _`_-"�'-' - 3 additional outputs can be used with ) ., circulators, dampers, or system aux 1 k'. h \', _ ■ Aux inputs -flow switch or end switch ■ Aux outputs -system pump or damper � ■ Modbus:` connectivity x ,� ,�- :m■ � � ■ Additional heat demand contact .. , , rot: 0- 4.-= ,.. .. . BOILER CIRCULATORS a 1-1/4"&1-1/2" flanges (220/299) Taco 0014 !x' r • 1-1/4" &1-1/2" flanges (399)Taco 0013 MULTIPLE BOILER FEATURES : , '�\ ; ' ■ Up to 8 boilers, multiple system '` df a Series, Parallel, or SmartSequencing 7 ■ Lead boiler rotation •_. \If,. ■ 2 network priorities for the system ■ 2 local priorities per boiler ■ 24 zone inputs and outputs with 8 total cascaded boilers ■ Aux inputs - flow switch or end switch + ■ System aux outputs - system pump or damper • - VENTING* ■ Direct vent 100 ft.for intake and 100 ft. for vent ■ Dual pressure zones • Common combustion air 'Please call your local Weil-McLain sales office for additional venting options. 220-399 I IC 5IONS 1'-> 4 23" ►- 21" 6*' " A ' 22 3/4" Y 41/8' k-143/4"--►-i ino g :: ' 't , 0 I 1 . A „ 45 , r 220=18 3/4” 43/16" 299/399=20 3/4" i - ix: A i 8Wi " 12Y" Y 1 3/4n -4--9 5/8,-----,--, --). -4—1 1/4" it-$"-0' t 165A6 I- F47 y� Q �NaQ = 4iH � S Qa = i z / ' /' i2 `r ! lyJ4 g c 1 PVC,CPVC, EVG 220 220 206 179 95.0% (AL2PP,S9-4C) 3"or4" 3"or4" 100' 11/4" 11/2" 3/4" 215 lbs. 4.6 Gal. PVC,CPVC, EVG 299 299 280 243 95.0% PP,SS 4" 4" 100' 11/2" 11/2" 3/4" 260 lbs. 7.0 Gal. (AL29-4C) PVC,CPVC, EVG 399 399 383• 333 96.5%` PP,SS 4" 4" 100' 11/2" 11/2" 3/4" 260 lbs. 6.7 Gal. (AL29-4C) "Evergreen 399 ratings are gross output and combustion efficiency INNOVATIVE CONTROL SYSTEM FEATURES ■ 3 programmable priorities ■ Integrated low water for up to three heat inputs protection UJIWA ■ Text display for easyoperation monitoring and ■ Dual temperature sensors on boiler outlet and flue diagnostics • Blower speed modulation • 0-10 VDC input modulation ■ Additional heat demand contact for hybrid system Contact your local Weil-McLain sales office for more information. NEW ENGLAND NEW YORK METRO MID-ATLANTIC 250 Richmond Street 220 White Plains Road 17000 Commerce Parkway Raynham, MA 02767 Suite 110 Suite B TEL: 508-822-3939 Tarrytown, NY 10591 Mount Laurel, NJ 08054 FAX: 508-822-0553 TEL: 914-789-3777 TEL:856-866-7400 FAX: 914-366-7407 FAX: 856-866-8828 CENTRAL AND WESTERN SALES ADMINISTRATIVE OFFICE 999 McClintock Drive 999 McClintock Drive Suite 200 Suite 200 Burr Ridge, IL 60527 Burr Ridge, IL 60527 TEL: 630-560-3738 TEL:630-560-3700 FAX:855-248-2777 FAX: 630-560-3769 Toll Free:800-854-5482 Weil-McLain is a leading North American designer and manufacturer of hydronic comfort heating systems for residential, commercial and institutional buildings since 1881. Weil-McLain has manufacturing facilities in Michigan City, Indiana and Eden, North Carolina, along with regional sales offices throughout the United States and an administrative office in Burr Ridge, Illinois. Building on a reputation of quality and innovation, Weil-McLain is committed to creating Simplified Solutions for our Complex WorldTm. Architects, engineers, contractors, facility managers and homeowners alike rely on Weil- McLain for their comfort heating needs. Installed in homes, offices, schools, restaurants, hotels and other facilities throughout North America, the Weil-McLain brand is among the most respected and often used in the building industry. Weil-McLain hydronic boilers and indirect-fired water heaters integrate the latest in advanced controls and materials including cast iron, stainless steel and aluminum heat exchanger technologies. The reliability and energy efficiency of our products has helped to make Weil- McLain industry leaders. Products are engineered with aesthetics, functionality, safety and structural tolerance in mind. By combining our expertise with the responsiveness of our support operations, we provide our customers with added value and peace of mind. WEIL-McLAIN® WM1507 BRO 020 EVG weil-mclain.com