Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report
. , r PRIME ELECTRICAL RECEIVED SERVICES, LLC. JUN 13 2019 Electrical ♦ Communications ♦ Life Safety♦ Security♦ CCTV CITY OF TIGARD PO Box 872395 Vancouver, WA 98687-Phone(503)318-5170 BUILDING DIVISION CCB#: 217825 FIRE ALARM SYSTEM SUBMITTAL Mary Woodward Elementary School 6960 SW Sandburd St. Tigard, OR 97223 June 10, 2019 Proposed by Prime Electrical Services PO 19-158 Project Manager: Oleg Primachenko Honeywell ® SILENT' KNIGHT 5496 Intelligent Power Module The 5496 intelligent power module is the most cost-effective power supply available today.It delivers 6 amps of notification appliance circuit power and built-in synchronization for appliances from System Sensor°,Gentex°, AMSECO,and Wheelock®.The 5496's advanced microprocessor design is years ahead of the competition.Its switch mode power supply design is up to 50%more efficient than competitive linear mode power supplies. The 5496 is a 6 amp notification power expander that provides its own AC power connection,battery charging circuit,and backup battery for use with the Honeywell Silent Knight series fire alarm control panels(FACPs).The 5496 is the cost-effective solution for powering notification appliances required by the Americans with Disabilities Act 110f14',”1,11,,,, (ADA).The 5496 has built-in ANSI cadence pattern.The output circuits can be programmed as notification appliance circuits,or as auxiliary power(configurable for constant,resettable,or door holder power). 1 Compatibility 5496 The 5496 is compatible with the following Honeywell Silent Knight FACPs: • 6820/6820EVS • 5820XL/5820XL-EVS • 6808 • 6700 • 5808 • 5700 FEATURES 8,4 BENEFITS •UL Listed for 6 amps • Built-in • NACs are • Communicates to the • Lightweight design of notification power synchronization for programmable as FACP via 4-wire SBUS adds to ease of • Power supply's appliances from notification appliance (wire runs up to 6000 installation and advanced switch mode Gentex,AMSECO, circuits,or as auxiliary ft) reduces shipping design reduces System Sensor,and power to be used as costs g Wheelock constant,resettable, • AC loss delay option damaging heat and shuts off power to • ANSI Cadence pattern managespower upto • Fourpower-limited or door holder power 9 non-essential high output capability 50%more efficiently notification outputs;2 • 3 amps per output current accessories built-in than other systems Class A oro Class B,or circuit like magnetic door • UL 864,1481&1971 • 24 VDC filtered output 1 Class A and 2 Class • Ground fault detector holders listed voltage • CSFMa roved • MEA approved pp • OSHPD(CA) OSP-0065-10(see accessories) 5496 Technical Specifications Fora complete listing of all compliance approvals and certifications,please visit 4 Outputs Programmable www.silentknight.com. as Notification Appliance Circuits, or as Auxiliary Power Microsoft,Windows,and the Windows Logo are registered trademarks or trademarks of Output 1 . SBUS Communication Microsoft Corporation. To a Compatible Silent Knight FACP System Sensor°and Output 2 `, Honeywell®are registered trademarks of Honeywell International,Inc Output 3 . This document is not intended to be used for Output 4 441 installation purposes.We try to keep our product information up-to Auxiliary Power Can Be date and accurate.We cannot cover all specific Programmed To Be Constant, applications or anticipate Resettable, or Door Holder Power all requirements.All specifications are subject to change without notice. For Technical Support, PHYSICAL required on each Class B circuit call 800-446-6444 Overall Dimensions:16"H x 12.25"W x 3"D(40.6 x Battery Charging Capacity:7.0—35.0AH 30.9 x 7.6 cm) Shipping Weight:8.7lbs ORDERING INFORMATION 5496:Intelligent Power Module ENVIRONMENTAL Operating Temperature:32°F to 120°F (0°C to ACCESSORIES 49°C) RBB: Remote Battery Box Accessory Cabinet.16" Humidity:10 to 93%relative humidity(non- Wx 10"H x 6"D(406 mm W x 254 mm H x 152 mm condensing) D) SK-SCK: Seismic Compliance Kit ELECTRICAL: AC Input:120VAC at 2.7A AGENCY LISTINGS AND APPROVALS Output:24VDC at 64 • CSFM approved Standby&Alarm Current:10mA Notification/Aux.Power Circuits:4 • NFPA 72 Output Configuration: 2 Class A(Style Z) • U L listed 4 Class B(Style Y) • FM approved 1 Class A&2 Class B Amps Per Output Circuit:3.0(6.0 amps total) • City of NY:429-90-E Vol XIV Notification Circuit Output:20.4—27.3VDC @ 3.0A each End-of-Line Resistance:4.7k W EOL resistor -a - -111- For rFor more information Learn more about Silent Knight's Product and other products available by visiting www.silentknight.com Honeywell Silent Knight 12 Clintonville Road Honeywell Northford,CT 06472 800-328-0103 Doc 3503871 Rev FI 11/17 www.silentknight.com ©2017 Honeywell International Inc. ®SILENT KNIGHT S®SimplEx Fire Alarm Control Panel Accessories Listings* System Batteries, Sealed Lead-Acid; with Applications Reference for Battery Cabinets, and Battery Cabinets with Charger Features Rechargeable, sealed lead-acid batteries: • Lead-calcium grid structure withh immobilize • electrolyte in absorbent separator • Low maintenance with no need to add water • Low self-discharge characteristics >xMmolex MOO • One-piece,high impact polystyrene cell cover with high reliability dual seal construction • UL 924 recognized pressure relief valves Available in a variety of capacities: • Batteries for internal mounting range from 6.2 Ah up to 50 Ah,depending on control panel cabinet size ° a • Larger batteries,up to 110 Ah,mount in external battery cabinets with models available with internal chargers v.. Battery cabinets with chargers: • Battery cabinets with charger communicate with their connected fire alarm control panel and are available for 4100ES/4010ES/4100U Series and 4010 Series panels Descri•tion Compatible Sealed Lead-Acid Batteries can be Installed Inside Fire Alarm Control Panel Cabinets Simplex®rechargeable sealed-lead acid batteries provide reliable and repeatable discharge and recharge characteristics for use in fire alarm and other systems applications.They are designed with immobilized ry electrolyte in an absorbent separator,allowing them to provide rated capacity on the first cycle. Because of their sealed construction,packaging is allowed within the system electronics enclosure(see illustration on page 2).When this is applicable,the quantity of system cabinets and the battery wiring distances are both minimized.Where required,external battery cabinets can Remote Battery Cabinets are Available for be close-nippled to the control panel to house larger Larger Battery Requirements batteries with battery chargers available in some battery cabinet sizes. Battery Details (Continued) Batter Details Shipping. Sealed lead-acid batteries are shipped via Charging.These batteries are intended to be used with ground or sea transportation only. They are not shipped compatible Simplex battery chargers. via air. Series Connections. These batteries are required to be Disposal.Battery chemicals and materials can be recycled. Refer to information shipped with the battery or connected in series to produce 24 V system voltage. Battery sets must be of identical voltage,model number, on its case.Return to the battery manufacturer or to a appearance,and approximately the same date of similarly qualified battery processing facility for proper manufacture for proper operation. disposal. Testing.Battery capacity testing is recommended to be Seismic Activity Applications. Battery brackets are available for systems tested for compliance with specific performed by using a sealed lead acid battery tester designed to withdraw a minimum of battery charge.The batteries.Please refer to data sheet S2081-0019 for preferred tester applies a variety of amplitude and details. duration controlled test pulses that compares terminal * Refer to details on page 4 and to the referenced individual product data sheets for agency voltage against those predicted for the specific battery listing status of battery cabinets and chargers.The batteries detailed in this document size.(Testing is available through your local Simplex meet the requirements of UL,ULC,and Factory Mutual for use with respective equipment product supplier.) battery chargers as listed on page 3.Contact your local Simplex product supplier for proper battery selection per system requirements.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. S2081-0006-22 10/2016 Batter Construction Reference Actual appearance will vary with battery size. Sealed outer cover Quick connect or post type terminal Vent hole (type varies with battery size) Potting material,black for . negative,red for positive (polarity is also clearly �`J�I marked with+and-) ii,-- ‹=i, ....4 -__111111. Pressure relief valve Inner cover p,i.___,.I is i Absorbent separator used to immobilize electrolyte ir-pprp II' Semi-permeable Lead-calcium grids 0 membrane separator Cell group or 1. Cell case(high impact polystyrene) Batte Size S•ecifications Capacity @ 20 Hour Height with Approximate Battery Model Discharge Rate Width* Depth* Terminals Weight* ---->2081-9272 6.2 Ah 6-1/8"(156 mm) 2-5/8"(67 mm) 4"(102 mm) 5.75 lbs(2.6 kg) 2081-9274 10 Ah 6"(153 mm) 4-1/16"(103 mm) 4"(102 mm) 9.2 lbs(4.2 kg) 2081-9288 12.7 Ah 6"(153 mm) 4"(102 mm) 4"(102 mm) 9 lbs(4.1 kg) 2081-9275 18 Ah 7-1/4"(184 mm) 3-3/8"(86 mm) 6-5/8"(168 mm) 14.3 lbs(6.5 kg) 2081-9287 25 Ah 6-5/8"(168 mm) 5"(127 mm) 7"(178 mm) 19.4 lbs(8.8 kg) 2081-9271 (rectangular case, 33 Ah 12-1/2"(318 mm) 3-3/8"(86 mm) 7-1/16"(179 mm) 26.6 lbs(12.1 kg) typically for service) 2081-9276 ("square"case, 33 Ah 7-3/4"(197 mm) 5-1/4"(133 mm) 6-3/4"(171 mm) 26.5 lbs(12 kg) use for new) 2081-9296 50 Ah 9"(229 mm) 5-1/2"(140 mm) 8-7/8"(225 mm) 41.8 lbs(19 kg) 2081-9279 110 Ah 11-3/16"(284 mm) 10-1/2"(267 mm) 9"(230 mm) 82 Lbs(37 kg) * Dimensions and weight are per battery and are for reference only. Exact size may vary. Refer to the tables on page 3 for mounting compatibility.These batteries are 12 V each and series connected for 24 V system use. NOTE: When wired in series for 24 V output,these batteries are to be of identical voltage,appearance,model number,and approximately the same date of manufacture. General Batter S•ecifications Nominal Voltage Rating 12 Volts per battery Discharge Rating 20 Hour Rate Typical Charge/Discharge Cycles 100 to 150 Preferred Charge Temperature Range 60° F to 90°F(15.6°C to 32.2°C) 11 2 S2081-0006-22 10/2016 Battery Compatibility for Fire Alarm Control Panel Mounting NOTE: Refer to individual fire alarm control panel product data sheets for additional battery application information Simplex Control Panel Model Series(see legend and notes below) Battery Capacity Model 4007ES& 4006& 4009 4100ES/ 4100&4120 4003EC 4004R 4005 4008 (all models) 4010 4010ES 41000 (2,4 or 6-Unit) __'-).2081-9272 6.2 Ah ✓ 1 ✓ 1 1 i 1 / 1 2081-9274 10 Ah ✓ 1 1 1 1 1 1 1 1 2081-9288 12.7 Ah 1 ✓ 1 1 1 1 1 1 1 2081-9275 18 Ah Ext Note 3 ✓ Ext Ext Note 2 1 1 1 2081-9287 25 Ah Ext Note 3 Ext Ext NA ✓ ✓ / 2081-9271 33 Ah Ext Note 3 Ext NA NA Note 3 ✓ ✓ Ext rectangular 2081-9276 33 Ah Ext Note 3 NA NA NA Note 3 1 ✓ 1 "square" 2081-9296 50 Ah NA Note 3 NA NA NA Note 3 Note 6 2 or 3 bay Ext 2081-9279 110 Ah Requires external battery cabinet,compatible with 4100ES,4010ES,4100,and 4120 Series only 1 =Can be placed in the respective equipment cabinet Ext=External battery cabinet is required, refer to selection chart on page 4 NA=Not applicable/not compatible NOTES: 1. These batteries meet the requirements of UL, ULC, and Factory Mutual for use with respective equipment battery chargers listed above.Contact your local Simplex product supplier for proper battery selection per system requirements. 2. 4010 Cabinets will accommodate 2081-9275, 18 Ah batteries,but will not allow bottom entry conduit. 3. Use 4081 series companion cabinet and charger,refer to page 4. 4. Some control panel models are listed for battery replacement reference only. 5. For 2 bay international applications only,50 Ah batteries will fit in the cabinet. External Batter Cabinet Corn.atibilit Reference Battery Cabinets without Chargers (connects to charger in panel) Battery Cabinet Panel Compatibility 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 2081-9280 4100ES,4010ES, NA NA NA NA NA I 41000, and 4100+ 2081-9281 multiple ✓ 1 ✓ 1 1 NA 2081-9282 4009-9801 multiple ✓ ✓** NA NA NA NA 4009-9802 multiple 1 NA ✓ NA NA NA Battery Cabinets with Chargers 2081-9275 2081-9287 2081-9271 2081-9276 2081-9296 2081-9279 Cabinet Panel Compatibility 18 Ah* 25 Ah Rectangular 33 Ah Square 33 Ah 50 Ah 110 Ah 4081-9301 4004R and 4010 ✓ ✓ ✓ 1 1 NA 1 4081-9302 4081-9306 4100ES,4010ES, NA NA NA NA ✓ ./ 4081-9308 and 4100U *Batteries smaller than those listed are normally mounted in the product cabinet **25 Ah capacity was effective as of 7/2005. 1=Can be placed in the respective equipment cabinet NA=Not applicable/not compatible 3 S2081-0006-22 10/2016 External Batter Cabinet S•ecification Reference Battery Cabinets Without Chargers; Shallow Design with Front Door Model Color Listings Description Dimensions 2081-9281 Beige UL and 2-Unit,4100 style cabinet without charger;with locking 25-3/4"W x 20-3/4"H x 6-3/4"D solid door and battery shelf,primarily for use with 50 Ah 2081-9282 Red FM batteries (654 mm x 527 mm x 171 mm) 4003-9860 Beige Multiple Intended for use with 4003EC systems,for up to 33 Ah 9-1/2"H x 24"W x 9"D batteries(refer to 4003EC data sheet S4003-0002) (241 mm x 610 mm x 229 mm) 4009-9801" Beige UL and For up to 25 Ah External battery cabinet without charger, 16-1/4"W x 13-1/2"H x 5-3/4"D FM batteries` with locking solid door and battery (413 mm x 343 mm x 146 mm)* For up to 33 Ah harness;for close-nippled mounting to 25-3/4"W x 20-3/4"H x 4-1/8"D 4009-9802 Beige UL batteries fire alarm control panel cabinet (654 mm x 527 mm x 105 mm) *Depth increased for 25 Ah batteries effective 7/2005. Chargers for use with 4010 Fire Alarm Control Panels and 4004R Suppression Release Systems (refer to data sheet S4081-0001) Model Color Input Voltage Description Dimensions 4081-9301 Beige Battery cabinet with charger for the 4010 and 4004R fire alarm control panel;for up to 50 Ah 120 VAC batteries;with front door 22-1/2"W x16-3/4"H x 8-3/8"D Listings include:UL, ULC, FM, CSFM, and MEA (572 mm x 425 mm x 213 mm) g 4081-9302 Red (NYC), see data sheet for details Battery Cabinet Without Charger for 110 Ah Batteries; for use with compatible panel mounted chargers (refer to data sheet S2081-0012) Model& Color Cabinet Description Compatible Charger Description Dimensions Listings Chargers 4010-9xxx 4010ES Main System Supply Series (MSS) 4100-9xxx 4100ES/4100U System Power Series Supplies(SPS) Battery cabinet for 4100-5111 2081-9279, 110 Ah 4100-5112 4100ES/41000 Additional SPS 2081-9280 batteries; includes 4100-5113 Listings Red 80 A battery fuse, 4100-5125 4100ES/41000 Remote Power 26-1/2"W x 12"H x 12"D include:UL terminals and 4100-5126 (673 mm x 305 mm x 305 mm) and CSFM battery connection 4100-5127 Supply(RPS) cables;see data 4100-5120 sheet for details 4100-5121 4100ES/41000 TrueAlert 4100-5122 Addressable Power Supply(TPS) 4100-0104 4100-0114 4100 Legacy power supplies 4100-0124 4100ES/4010ES/41000 Compatible Battery Cabinet With Charger for 110 Ah Batteries (for ULC listed systems and for other applications unable to use panel mounted power supply charger; refer to data sheet S4081-0002) Model Color Input Voltage Description Dimensions Battery cabinet with charger for up to 110 Ah 4081-9306 Red 120 VAC batteries; NOTE: Required for ULC listed charging of 27-7/8"W x 13-1/2"H x 14-5/8"D 220/230/240 VAC, 110 Ah batteries;Listings include:UL, ULC, FM, (708 mm x 343 mm x 371 mm) 4081-9308 Red multi-tapped CSFM, and MEA(NYC), see data sheet for details 4100-9837 Green LED Power-on Indicator Kit, required for ULC listing,mounts above access panel using knockout provided TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited. ®S i m p 1 Ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S2081-0006-22 10/2016 www.simplex-fire.com )2014 Tyco hire Protection Products.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. Wheelock° ExcederTM Series 00 COOPER Notification ED TM Finally, Design and Safety Meet... .r • t' s l E Ceiling Wall Description: The Wheelock®ExcederTM Series of notification appliances feature a sleek modern design that will please building owners with reduced - Save up to 48% in current draw* total cost of ownership. Installers will benefit from its comprehensive feature list, including the most candela options in one appliance, low current draw, no tools needed for setting changes,voltage test - Up to 9 models now in 1 appliance points, 12/24 VDC operation,universal mounting base and multiple mounting options for both new and retrofit construction. up 14% installation** - Save to cost of The Wheelock®ExcederTM Series incorporates high reliability and high efficiency optics to minimize current draw allowing for a greater number of appliances on the notification appliance circuit.All strobe models feature an industry first of 8 candela settings on a single Sleek Modern Aesthetics appliance.Models with an audible feature 3 sound settings(90,95, 99 dB).All switches to change settings, can be set without the use of a tool and are located behind the appliance to prevent tampering. trlij Finger Slide Switches Wall models feature voltage test points to take readings with a voltage meter for troubleshooting and AHJ inspection. The Wheelock® ExcederTM Series of wall and ceiling notification Voltage Test Points appliances feature a Universal Mounting Base (UMB) designed to simplify the installation and testing of horns, strobes, and combination horn strobes. The separate universal mounting 12Multiple Voltages base can be pre-wired to allow full testing of circuit wiring before vbc the appliance is installed and the surface is finished. It comes complete with a Contact Cover for protection against dirt,dust,paint 3 Audible Settings and damage to the contacts. The Contact Cover also acts as a 90,95,ss dB shunting device to allow pre-wire testing for common wiring issues. The Contact Cover is polarized to prevent it from being installed incorrectly and prevents the appliance from being installed while U 8 Candela Settings*** it is on the UMB. When the Contact Cover is removed the circuit Wall-15/1575/30/75/95/110/135/185 will show an open until the appliance is installed.The UMB allows Ceiling-15/30/60/75/95/115/150/177 for consistent installation and easy replacement of appliances if *** required. Wall models provide an optional locking screw for extra Universal Mounting Base secure installation, while the ceiling models provide a captivated I Ceiling and Wall Mounts to 5 Backbox Types screw to prevent the screw from falling during installation. Environmentally Friendly Low Current Draw Compatibility and Requirements -Synchronize using the Wheelock®Sync Modules or panels with built-in Wheelock®Patented Sync Protocol -Compatible with UL"Regulated Voltage"using filtered VDC or unfiltered VRMS input voltage -Strobes produce 1 flash per second over the"Regulated Voltage" range *Compared to competitive models "`Patented **Compared to previous models Y . NOTE:All CAUTIONS and WARNINGS are identified by the symbol .All warnings are printed in bold capital letters. A WARNING: PLEASE READ THESE SPECIFICATIONS AND ASSOCIATED INSTALLATION INSTRUCTIONS CAREFULLY BEFORE USING,SPECIFYING OR APPLYING THIS PRODUCT. VISIT WWW.COOPERNOTIFICATION.COM OR CONTACT COOPER NOTIFICATION FOR THE CURRENT INSTALLATION INSTRUCTIONS. FAILURE TO COMPLY WITH ANY OF THESE INSTRUCTIONS,CAUTIONS OR WARNINGS COULD RESULT IN IMPROPER APPLICATION, INSTALLATION AND/OR OPERATION OF THESE PRODUCTS IN AN EMERGENCY SITUATION,WHICH COULD RESULT IN PROPERTY DAMAGE,AND SERIOUS INJURY OR DEATH TO YOU AND/OR OTHERS. General Notes: General Notes: •Strobes are designed to flash at 1 flash per second minimum over their"Regulated Voltage Range. •All candela ratings represent minimum effective strobe intensity based on UL Standard 1971. •Series Exceder Strobe products are Listed under UL Standards 1971 and 464 for indoor use with a temperature range of 32°F to 120°F(0°C to 49°C)and maximum humidity of 93%(±2%)UL 464(85%UL 1971). •Series Exceder horns are under UL Standard 464 for audible signal appliances(Indoor use only). Low Current Draw = Fewer Power Supplies Strobe Ratings per UL Standard 1971 UL Max Current* 24 VDC/24 FWR 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC ST 8.0-33.0 0.057 0.070 0.085 0.135 0.163 0.182 0.205 ~ '-41= 0.253 0.110 0.140 STC 8.0-33.0 0.061 '' 1 0.085 0.103 0.135 0.163 0.182 U 0.205 0.253 0 110litth Horn Strobe Ratings per UL 1971 &UL 464 at 24 VDC UL Max Current`at 99 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.082 0.095 0.102 ,‘K1 0.148 0.176 0.197 0.242 0.282 0.125 0.159 HSC 8.0-33.0 0.082 0.102 0.141 0.148 0.176 0.197 0.242 0.282 ' 0.125 UL Max Current`at 95 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.073 0.083 0.087 -1 0.139 0.163 0.186 Pr 0.230 ~_ 0.272 0.122 0.153 HSC 8.0-33.0 0.073 0.087 0.128 0.139 0.163 , 0,186 ti. 0.230 0.272 0.122 UL Max Current*at 90 dBA 24 VDC 12 VDC Model Regulated Voltage 15 15/75 30 60 75 95 110 115 135 150 177 185 15 15/75 Range VDC HS 8.0-33.0 0.065 0.075 0 084 0.136 0.157 0.184 0.226 ti • ° 0.267 0.120 0.148 HSC 8.0-33.0 0.065 ` ti 0.084 0.120 0.136 0.157 t 0.184 0.226 0.267 0.120 Horn Ratings per UL 464 Model Regulated Voltage 99 dB 95 dB 90 dB Range VDC HN 16-33.0 0.064 0.044 0.022 HNC 16-33.0 0.084 0.044 0.022 HN 8.0-17.5 0.047 0.026 0.017 4<i(4„. sk HNC 8.0-17.5 0.047 0.026 0.017 =;, *UL max current rating is the maximum RMS current within the listed voltage range(16-33 VDC for 24 VDC units). For strobes the UL max current is usually at the minimum listed voltage (16 VDC for 24 VDC units). For audibles the max current is usually at the maximum listed voltage(33 VDC for 24 VDC units). For unfiltered ratings, see installation instructions. Specification & Ordering Information Strobe Sync w/SM, Mounting DSM or 12/24 VDC* Model Candela PS-6&PS-8 ai Options Horn Strobes 0 0 ------> NTa HSR 15/1575/30/75/95/110/135/185 X X UMB** O HSW 15/1575/30/75/95/110/135/185 X X UMB** o HSRC 15/30/60/75/95/115/150/177 X X _ UMB** N HSWC 15/30/60/75/95/115/150/177 X X "6 UMB** o Strobes o ___.> E STR .5 15/1575/30/75/95/110/135/185 X X in UMB** �N STW 'p 15/1575/30/75/95/110/135/185 X X ri UMB** E STRC `— 15/30/60/75/95/115/150/177 X X g UMB** STWC p 15/30/60/75/95/115/150/177 X X d' UMB** NHornai i c m 0 HNR X X tv UMB** HNW X X ai UMB** (TS HNRC V X X as UMB** W 00 rn X MINIML UMB** *12 VDC models feature 15&15/75 settings **UMB=Universal Mounting Base Model Legend ; HN = Horn ST =Strobe "�'. ±t ir- HS = Horn Strobe C = Ceiling Mount / W =White R / , = Red �' . Example 1: STRC=Strobe, Red, Ceiling Mount Example 2: HSR= Horn Strobe, Red, Wall Mount Example 3: HSW= Horn Strobe, White,Wall Mount Example. Example: HSWC * 0 0 , ® *UMB Contact Cover Voltage test points for quick 8 candela settings Common base for wall and ceiling with 5 troubleshooting and easy spot mounting options checking (wall models only) NOTE:Due to continuous development of our products,specifications and offerings are subject to change without notice in accordance with Cooper Wheelock Inc.,dba Cooper Notification standard terms and conditions. 1. Architects and Engineers Specifications The notification appliances shall be Wheelock°ExcederTM Series HS Audible Strobe appliances, Series ST Visual Strobe appliances and Series HN Audible appliances or approved equals.The Series HS and ST Strobes shall be listed for UL Standard 1971 (Emergency Devices for the Hearing-Impaired)for Indoor Fire Protection Service. The Series HS and HN Audibles shall be UL Listed under Standard 464(Fire Protective Signaling). All Series shall meet the requirements of FCC Part 15 Class B.All inputs shall be compatible with standard reverse polarity supervision of circuit wiring by a Fire Alarm Control Panel(FACP)with the ability to operate from 8 to 33 VDC. Indoor wall models shall incorporate voltage test points for easy voltage inspection. The Series HS Audible Strobe and ST Strobe appliances shall produce a flash rate of one (1)flash per second over the Regulated Voltage Range and shall incorporate a Xenon flashtube enclosed in a rugged Lexan®lens.The Series shall be of low current design. Where Multi-Candela appliances are specified, the strobe intensity shall have 8 field selectable settings at 15, 15/75, 30, 75, 95, 110, 135, 185 candela for wall mount and 15, 30, 60, 75, 95, 115, 150, 177 candela for ceiling mount. The selector switch for selecting the candela shall be tamper resistant. The 15/75 candela strobe shall be specified when 15 candela UL Standard 1971 Listing with 75 candela on-axis is required (e.g.ADA compliance). Appliances with candela settings shall show the candela selection in a visible location at all times when installed. The audible shall have a minimum of three(3)field selectable settings for dBA levels and shall have a choice of continuous or temporal (Code 3)audible outputs. The Series HS Audible Strobe, ST Strobe and Series HN Audible shall incorporate a patented Universal Mounting Base that shall allow mounting to a single-gang, double-gang, 4-inch square, 3.5-inch octal, 4-inch octal or 100mm European type back boxes. Two wire appliance wiring shall be capable of directly connecting to the mounting base. Continuity checking of the entire NAC circuit prior to attaching any notification appliances shall be allowed. Product shall come with Contact Cover to protect contact springs. Removal of an appliance shall result in a supervision fault condition by the Fire Alarm Control Panel(FACP). The mounting base shall be the same base among all horn, strobe, horn strobe, wall and ceiling models. All notification appliances shall be backwards compatible. The Series HS and ST wall models shall have a low profile measuring 5.24"H x 4.58"Wx 2.19"D. Series HN wall shall measure 5.24" H x 4.58"W x 1.6" D. The Series HSC and STC shall been round and have a low profile with a diameter of 6.68"x 2.63" D. Series HNC ceiling shall have a diameter of 6.68"x 1.50" D. When synchronization is required,the appliance shall be compatible with Wheelock®'s SM, DSM Sync Modules, Wheelock®Power Supplies or other manufacturer's panels with built-in Wheelock®Patented Sync Protocol.The strobes shall not drift out of synchronization at any time during operation. If the sync protocol fails to operate, the strobe shall revert to a non-synchronized flash-rate and still maintain (1)flash per second over its Regulated Voltage Range.The appliance shall also be designed so that the audible signal may be silenced while maintaining strobe activation when used with Wheelock®synchronization protocol. Wall Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC Ceiling Appliances—UL Standard 1971, UL Standard 464, California State Fire Marshal(CSFM), ULC =MM S WE ENCOURAGE AND SUPPORT NICET CERTIFICATION 3 YEAR WARRANTY Exceder- Spec Sheet 11/09 NJ Location FL Location VA Location 273 Branchport Ave. 7565 Commerce Ct. 4401 Wilson Boulevard,Suite 220 Long Branch,NJ 07740 Sarasota, FL 34243 Arlington,VA 22203 P:800-631-2148 P:941-487-2300 P:877-459-7726 F:732-222-8707 F:941-487-2389 F:703-294-6560 www.coopernotification.com Cooper Notification is Wheelock" 1;41111) SAFEPATIT WAVE COOPER Notification '` `''` INTELLIKNIGHT ACCESSORY itSILENT Addressable Photoelectric il KNIGHT Smoke Detector by Honeywell Detect smoldering fires quickly and get help fast with IntelliKnight® photoelectric smoke detectors. IntelliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where smoldering fires are a threat. In addition to accurately detecting a smoldering fire, each SD505-PHOTO photoelectric detector has a unique address, which is recognized by the IntelliKnight panel. No precious seconds are wasted in determining location of an alarm. The SD505-PHOTO compensates automatically for contamination in the environment.And detector testing is simple—even from a remote site. Like other IntelliKnight detector models, the SD505-PHOTO offers a low profile for pleasing aesthetics. The IntelliKnight family of detectors has been designed to use a common base, Model SD505-6AB, allowing complete application and placement flexibility. Combine all this with the features you've come to expect from Silent Knight smoke detectors—easy installation, stable operation, RF/transient protection, and vandal-resistant locking—and it adds up to a flexible solution for all your fire protection needs. _ ---->Model SD505-PHOTO approximately every 15 seconds, Analog /Addressable indicating that the head is Photoelectric Type Smoke communicating with the loop. The Detector LED lights continuously during the The SD505-PHOTO is particularly alarm period. /aft 1 suited to detecting dense smoke Features • ` typical of fires involving materials • Low profile, 2 inches, including such as soft furnishings, plastic, base foam or other similar materials • Simple and reliable addressing ., which tend to smolder and produce without mechanical switches large visible particles. SD505-PHOTO Smoke Detector • Automatic compensation for The detector features automatic sensor contamination compensation for contamination • Built-in fire test feature Ambient Temperature: 32°F to and a simple detector calibration • Simple detector calibration 120°F (0°C to 49°C) test procedure that can be run from testing through the control panel the panel or remotely (using the or remotely through a Mounting: 4" Square, 4" OCT, WindowsTM based downloading WindowsTM based computer Single gang mud ring software). software. Relative Humidity: 85% non- Operation • Vandal-resistance locking condensing The SD505-PHOTO units made up features of an LED light source and a silicon • Field cleanable Air Velocity: 0 - 300 FPM photo diode receiving element. In a • UL listed, meets NFPA 72 Ch 7 Compatible Bases: SD505-6AB normal standby condition, the requirements (Sold Separately) SD505-61B receiving element receives no light • CSFM approved SD505-6RB from the pulsing light source. In the • MEA approved SD505-6SB event or fire, smoke enters the • FM Approved detector and light is reflected from Specifications the smoke particles to the receiving element. Operating Voltage: 24-41 VDC The light received is converted into Current Consumption: an electronic signal. Under normal Standby: .55 mA P/N 350225 Rev G conditions, the status LED blinks Alarm: .55 mA ©2015 Honeywell International Inc. '1 ELLIKNIGHTACCESSORY Model SD505-PHOTO Addressable Photoelectric Smoke Detector Engineering Specifications The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector Silent Knight SD505-PHOTO. The combination detector head, and twist-lock base, shall be UL®listed compatible with Silent Knight's IntelliKnight fire control panels. The base shall permit direct interchange with Silent Knight SD505-HEAT Heat Detector. Base shall be the appropriate twist-lock base SD505-6AB. The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch. The calibration of the detector shall be capable of being selected and measured by the control panel without the need for external test apparatus. The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The locking feature shall be field selectable as required. The SD505-PHOTO shall automatically perform a functional test of the detector. The test method shall simulate effects of products of combustion in the chamber to ensure testing of detector circuits. N Diameter=5-15/16" N / Diameter = 3-15/16" of 14 \ .. 7; , 441 ar, j Height = 2 inches, 0-1 . s including base ®SILENT .IQVIGHT / g- Model SD505-6AB Detector Base Model SD505-PHOTO Detector Head (front view) (front view) SILENTN 41t This document is not intended to be used for installation purposes. We try to keep our KNIGHT product information up-to-date and accurate. We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. For more m information, contact Silent Knight 12 Clintonville Road, Northford, CT 06472-1610 Phone: by Honeywell (800)328-0103, Fax: (203)484-7118. www.silentknight.com