Loading...
Report (46) l h MST2019-00204 � 14232 SW GOLD COAST MST2019-00205 114228 SW GOLD COAST i 1-25-16 N Roseburg 1 MST2019-00206 114224 SW GOLD COAST " " 2:28pm AForest ProductsCompany MST2019-00207 114220 SW GOLD COAST FEB (n� 1Q 1 of 1 CS Beam 2015.7.0.1 J V 2U^J kmBeamEngine 4.13.10.1 MST2019-00208 14218 SW GOLD COAST Materials Database 1543 _...... ----- --- __--.. Member Data Description: litVy Member Type: Joist Application: Floor 001,0 COL- Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued&Nailed Filename: Beam1 Other Loads Type Other Dead (Description) Side Begin End Start End Start End Category Point(PLF) Top 0' 0.00" 0 100 Live Point(PLF) Top 0' 0.00" 50 34 Roof Yousiiiii.aii - ---am / / / / / 2 0 0 10 6 0 ® 14 3 0 la) 2690 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 0.000" Wall DFL Plate(625psi) 3.500" 3.500" 678# - 2 12' 6.000" Wall DFL Plate(625psi) 3.500" 3.500" 1030# - 3 26' 9.000" Wall DFL Plate(625psi) 3.500" 1.750" 418# - Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Roof Dead 1 369#(277p1f) 82#(62plf) 309#(232p1f) 2 832#(624plf) -16#(-12plf) 199#(149p1f) 3 322#(242plf) 2#(2p1f) 95#(72p1f) Design spans 2' 0.000"(left cant) 10' 6.000" 14' 0.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1255.'# 2820.'# 44% 20.22' Odd Spans D+L Negative Moment 1302.'# 2820.'# 46% 12.5' Adjacent 2 D+L Shear 579.# 1220.# 47% 12.5' Adjacent 2 D+L Cant.Shear,Lt 317.# 1220.# 25% 1.99' Total Load D+L End Reaction 418.# 1151.# 36% 26.75' Odd Spans D+L Int.Reaction 1030.# 1775.# 58% 12.5' Adjacent 2 D+L TL Deflection 0.2140" 0.7016" L/786 20.22' Odd Spans D+L LL Deflection 0.1661" 0.3508" L/999+ 20.22' Odd Spans L TL Defl.,Lt. 0.0489" 2L/980 0' Odd Spans D+L LL Defl.,Lt. -0.0334" 2L/999+ 0' Even Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only SIMPSON All product names are trademarks of their respective owners KAMI L HENDERSON Strong-Tie EWP MANAGER Copyright(C)2015 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. 503-858-9663 NROseburgr . J7 MAIN 1-25-16 2:26pm m. A I orest Products Company 1 of 1 CS Beam 2015.7.0.1 kmBeamEngine 4.13.10.1 Materials Database 1543 Member Data Description: Member Type: Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam 1 n 1r / / / 11 0 0 14 6 0 ® 2560 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 312# -15# 2 11' 0.000" Wall DFL Plate(625psi) 3.500" 3.500" 1103# — 3 25' 6.000" Wall DFL Plate(625psi) 3.500" 1.750" 418# — Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 257#(192p1f) 55#(42p10 2 849#(637p1f) 255#(191 plf) 3 327#(245p1f) 91#(68p1f) Design spans 10' 9.375" 14' 3.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1254.'# 2820.'# 44% 19.57' Even Spans D+L Negative Moment 1441.'# 2820.'# 51% 11' Total Load D+L Shear 596.# 1220.# 48% 11' Total Load D+L End Reaction 418.# 1151.# 36% 25.5' Even Spans D+L Int.Reaction 1103.# 1775.# 62% 11' Total Load D+L TL Deflection 0.2167" 0.7141" L/790 18.85' Even Spans D+L LL Deflection 0.1753" 0.3570" L/977 18.85' Even Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% SIMPSON All product names are trademarks at their respective owners KAMI L HENDERSON EWP MANAGER Strong-Tie Copyright(C)2015 by Simpson Strong-lie Company Inc.ALL RIGHTS RESERVED, PACIFIC LUMBER&TRUSS "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. 503-858-9663