Loading...
Report (26) Tpeyid:Frioex \i )C\-- a(�1 C�,2e�1h�,,r13 51171MTrueAlert Multi-Candela Notification Appliances uI,u�c,CSFM LisVisible Notification Appliances with Synchronized Flash; Non-Addressable,SmartSync Approved;MEA(NOperation Compatible Acceptance` Features Description Multi-Candela TrueAlert synchronized strobes provide convenient '': installation to standard electrical boxes.The enclosure designs are both ` impact and vandal resistant and provide a convenient strobe intensity selection.Since each model can be selected for intensity output,on- site model inventory is minimized and changes encountered during i°■* o r construction can be easily accommodated IVrW II ount strobe housings are a one-piece assembly(including lens) FIRE w F I R E v 1.fi ounts to a single or double gang,or 4"square standard electrical ox.The cover can be quickly removed(a tool is required)and covers are Figure 1: Wall Mount Strobes JUN — 5 2014vailable separately for color conversion. j CITY OF 71GANI-iling mount strobes install using standard single gang electrical ai s Color choice is determined by model number. FIRE I, FIRE I SUILDING DIVIS .} P:>/ Strobe Intensity Selection` 1 , i '� �I, ' During installation,a selection plug at the back of the housing determines the desired strobe intensity.An attached flag with black Figure 2: Ceiling Mount Strobes letters on a highly visible yellow background allows the selected intensity Visible only(V/O)24 VDC notification appliances with high output to be seen at the side of the strobe lens. xenon strobe,available for wall or ceiling mount: • Intensity is selectable as 15,30,75,or 110 candela with visible Strobe Application Reference selection jumper secured behind strobe housing Proper selection of visible notification is dependent on occupancy, • Operation is compatible with ADA requirements(refer to Installation location,local codes,and proper applications of:the National Fire Alarm Reference,Surface or Semi-Flush Wall Mounting) Code(NFPA 72),ANSI A117.1;the appropriate model building code: BOCA,ICBO,or SBCCI;and the application guidelines of the Americans • Polarized input allows connection to compatible reverse polarity, with Disabilities Act(ADA). supervised notification appliance circuit(NAC) • Regulated circuit design ensures consistent flash output and provides Synchronized Strobes controlled inrush current • Rugged,high impact,flame retardant thermoplastic housings are Multiple Strobes.When multiple strobes and their reflections can be available in red or white with clear lens seen from one location,synchronized flashes reduce the probability of photo-sensitive reactions as well as the annoyance and possible • Listed to UL 1971 and ULC S526 distraction of random flashing.These multi-candela strobes are Strobes provide synchronized flash for use with: synchronized over a two-wire circuit when connected to compatible NACs,to compatible Synchronized Flash Modules,or to SmartSync •Simplex@ fire alarm control panels with NACs selected to provide Control Modules. strobe synchronization or SmartSync two-wire control •4009 IDNet NAC Extenders SmartSync Two-Wire Control • Separate strobe Synchronization Modules that are available for Class B Some applications desire the audible notification appliances to be or Class A operation capable of being silenced before the alarm condition is reset(on-until- • Separate SmartSync Control Modules(SCMs)that provide Class B or silenced)while the visible notification appliances are kept activated until Class A output from conventional NAC inputs the alarm condition is reset(on-until-reset).SmartSync operation mode Strobe housings provides flexible,easy,and convenient semi- provides this function using a single circuit(two wire operation). flush or surface wall mounting: • Rear of housing does not extend into box SmartSync Control Sources •Wall mount strobes easily mount to single gang,double gang,or 4-inch SmartSync two-wire control is available from: square outlet box •4006,4007ES Hybrid,4008,4010,4010ES,4100ES,and 41000 Fire • Ceiling mount strobes mount to single gang boxes Alarm Control Panels(refer to individual product data sheets for more information) Wall mount strobe features: •4009 IDNet NAC Extenders(refer to data sheet 54009-0002) • Wiring terminals are accessible from the front of the housing providing easy access for installation,inspection,and testing • SmartSync Control Module(SCM)Model 4905-9938(refer to data Covers are available separately to convert housing color sheet 54905-0003) Additional SmartSync compatible notification appliances include Optional adapters and wire guards: separate horns and combination horn/strobe notification appliances. •Wall mount strobe adapters are available to cover surface mounted For more information refer to TrueAlert Non-Addressable,Multi-Candela electrical boxes and to adapt to Simplex 2975-9145 boxes Notification Appliances Installation Instructions,579-548. • UL listed red wire guards are available for wall or ceiling mount strobes* *Additional listings may be applicable;contact your local product supplier for the latest status, COPY Vft° S4906-0001 Rev.6 3/2019 £SimplEx Visible Notification Appliances with Synchronized Flash; Non-Addressable,SmartSync Operation Compatible Product Selection Table 1:Multi-Candela Visible Notification Appliances(Strobes) Model Mounting 1, Housing Color Lettering Description z ,, .. ;:i '906-9101 Wall Red FIRE(white) 4906-9103 White FIRE(red) 4906-9102 Red FIRE(white) 4906-9104 White FIRE(red) Multi-candela strobe with intensity selectable as:15,30,75,or 110 4906-9114 Red ALERT(white) candela;synchronized flash rate;SmartSync two-wire control compatible 4906-9115 Ceiling White ALERT(red) 4906-9116 Red Blank(white) 4906-9117 White Blank(red) Table 2:Wall Mount Strobe Adapters Model Description p (Dimensions 4905-9937 Red 5-3/8"H x 5-1/4"W x 1-5/8"D Surface Mount Adapter Skirt;use to cover 1-1/2"(38 mm)deep surface 4905-9940 White mounted boxes (136 mm x 133 mm x 41 mm) Total depth with strobe-4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for retrofit, 8-5/16"x 5-3/4"x 0.060"Thick may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box,requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Table 3:Ceiling Mount Strobe Adapter 'Model Description 'Dimensions - - 4905 9910 Surface Mount Adapter Plate;zinc plated;required for mounting to handy box;4-7/8"x 3-1/8"x 0.060"D not needed when using 4905-9926 guard (124 mm x 79 mm x 1.5) Table 4:Synchronization Modules(refer to data sheet 54905-0003 for additional information) Model Description [Dimension I 4905-9914 Class B Synchronized Flash Module;epoxy encapsulated with in/out 18 AWG 1-3/8'x 2-7/16"x 13/16" 4905-9922 Class A (0.82 mm2)wire leads,rated for 2 A NAC,requires 5 mA for power (35 mm x 62 mm x 20 mm) 4905 9938 SmartSync Control Module with Class B or Class A output;mounts in 4"(102 mm) 4"x 4-1/8"x 1-1/4"D square box (102 mm x 105 mm x 32 mm) Table 5:Replacement Covers and Guards e h Description y, Dimensions 4905-9992 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D For Wall mount strobes 4905-9993 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) 4905-9961* Wall mount 6-1/16"H x 6-1/16"W x 3-1/8"D Red wire guard with mounting plate,compatible with semi- (154 mm x 154 mm x 79 mm) flush or surface mounted boxes 6-1/8"x 4-3/8"x 2-7/8" 4905-9926* Ceiling mount deep (156mmx111 mmx73mm) *UL listed by Space Age Electronics Inc. Page 2 54906-0001 Rev.6 3/2019 • ESSimplEx Visible Notification Appliances with Synchronized Flash; Non-Addressable, SmartSync Operation Compatible Strobe Specifications Table 6:Wall Mount or Ceiling Mount,Common Specifications Specification ',' � Rating i Rated Voltage Range Regulated 24 VDC;see Note 1 below - Flash Rate 1 Hz Synchronized NAC Loading Up to 35 synchronized strobes maximum per NAC Temperature Range 32°to 122°F(0°to 50°C) Humidity Range 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Wall Maximum RMS Current Rating per Strobe 15 cd 30 cd 75 cd 110 cd Mount Setting(see Note 2 below) 60 mA 94 mA 186 mA 252 mA Reference RMS Currents at 18 VDC 53 mA 84 mA 165 mA 224 mA other voltages 24 VDC 40 mA 63 mA 124 mA 168 mA Housing Dimensions(with lens) 4-3/4"L x 2-5/16"W x 2-5/8"D(121 mm x 75 mm x 67 mm) Ceiling Maximum RMS Current Rating per Strobe 15 cd 30 cd 75 cd 110 cd Mount Setting(see Note 2 below) 75 mA 125 mA 233 mA 316 mA Reference RMS Currents at 18 VDC 67 mA 111 mA 207 mA 281 mA other voltages 24 VDC 50 mA 83 mA 155 mA 211 mA Note: 1. "Regulated 24 VDC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the strobe.Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference,Surface or Semi-Flush Wall Mounting /L� LTh ��� f/ 0 0 Mounting is compatible with / \ \ single gang,double gang,and I o I �I 4"(102 mm)square boxes, • IMPORTANT!WALL MOUNT 1-1/2"(38 mm)deep,by others _rou I J Qo 1_ 1 ,/_ � INSTALLATION HEIGHT REFERENCE i; li Bottom of lens ,7,- i, is either even _ Alii V with,or slightly Electrical Or 1 above bottom box outline Wiring access hole ,tt O U/ / of compatible 1 U /e boxes 1 Wiring terminals , — — (i i1 j i . `{"' h Mounting Holes: 4-- NFPA 72 requires 80"(2.03 m) i 4"square(4) Single gang(2) that the entire lens minimum O "� - be not less than y . — Double gang(3) 80"and not greater than 96"above the • finished floor Transparent housing and lens assembly Intensity selection ;"o plug,accessible only ;s _ from rear of housing; 1s L factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot Page 3 S4906-0001 Rev.6 3/2019 S Simplex Visible Notification Appliances with Synchronized Flash; Non-Addressable, SmartSync Operation Compatible Ceiling Mount Strobe Installation Reference Handy box,1-1/2"(38 mm)deep Single gang box(Wiremold (RACO 650 or equal)or single gang V5744S)2-1/4"(57 mm) box,2-1/2"(64 mm)deep(RACO 519 deep,supplied by others or equal)supplied by others Also can be attached to boxes 17/ mounted to drop ceiling T-bar with clips(ERICO No.512 or equal) 0 U 0 Adapter Plate,required for surface mount with handy box unless Mill.1111.111111ff using the wire guard " � "l 1HII hCeiling mount strobe F 1 U g_ Optional wire guard pr.._ .._,.. I with mounting plate 4.,11 I ,' Strobe intensity 11' ® . ' �. , , viewing slot 41"—,0107I be s �Intensity selection plug, accessible only from rear of lens housing;factory setting is 15 cd Figure 3: Ceiling mount strobe installation reference Note:Figure 3 shows: •4905-9910 Adaptor Plate. • 4905-9926 Wire guard. Wall Mount Installation Reference;Adapter Plate,Guard,and Adapter Skirt Surface Mounting Reference Box with Optional Adapter Skirt box and Optional Wire Guard `�' - n Surface profile,mount conduit and - O box shown for reference�. 4"(102 mm)square 1-1/2" (38 mm)deep iiI'rF O O Optional _' Wire GuardStrobe .. ....... R FIRE Adapter Plate Optional Surface Mount Adapter Skirt, O Optional Wire Guard 1-1/2"deep: Red; White (shown here for reference only, (conduit knockouts Adapter Plate can be used on other mounting options) are provided on all four sides) Figure 4: Wall Mount Installation Reference;Adapter Plate,Guard,and Adapter Skirt Note:Figure 4 shows: • 4905-9931 Adapter Plate. • 2975-9145 Box. •4905-9961 Optional Wire Guard. • Optional Surface Mount Adapter skirt available in: - Red:4905-9937. - White:4905-9940. ©2019 Johnson Controls.All rights reserved.All specifications and other information shown were current as of document revision and are subject to change without notice.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co. Simplex,and the product names listed in this material are marks and/or registered marks.Unauthorized use is strictly prohibited.NEPA 72 and National Fire Alarm Code are registered trademarks of the National Fire Protection Association(NEPA). 54906-0001 Rev.6 3/2019 ®Simplex TrueAlert Multi-Candela Notification Appliances UL, ULC, CSFM Listed; FM Approved; SmartSync Operation AudibleNisible Notification MEA (NYC)Acceptance* with Horn and Synchronized Flash, Non-Addressable Featuresi..........-------1 Audible/visible(AN) notification appliances with . "1^^ , efficient electronic horn and high output xenon strobe, available for wall or ceiling mount • Operation is compatible with ADA requirements(refer to important installation information on page 3) • Rugged,high impact,flame retardant thermoplastic t r 4mor ,°. housings are available in red or white with clear lens Operates over a two-wire SmartSync circuit to F I R Ew provide: • Horns that are controlled separately from strobes on the FIRE same two-wire circuit 11•111111111111111T • "On-until-silenced"and"on-until-reset"operation on the same two-wire pair ill!" • SmartSync horn activation of Temporal pattern,March FIRE �",�`�k� Time pattern(at 60 BPM),or on continuously • Strobe appliances on the same circuit operating ata "11•111111111= synchronized 1 Hz flash rate • Class B operation requires connection to a compatible 1 � SmartSync NAC or to SmartSync Control Module (SCM)4905-9938 Wall and Ceiling Mount A/Vs • Class A operation when connected to the 4905-9938 Descri•tion SCM or with 4100U series fire alarm control panel NACs Multi-Candela TrueAlert ANs with horn and Wall mount ANs features: synchronized strobe provide convenient installation to standard electrical boxes. The enclosure designs are • Wiring terminals are accessible from the front of the both impact and vandal resistant and provide a convenient housing providing easy access for installation, strobe intensity selection.Since each model can be inspection,and testing selected for strobe intensity output,on-site model • Covers are available separately to convert housing color inventory is minimized and changes encountered during • Available UL listed sound damper for locations construction can be easily accommodated. requiring attenuation of 5 to 6 dBA(stairwells,small rooms,highly reverberant areas,etc.) Wall mount A/V housings are a one-piece assembly (including lens)that mounts to a single or double gang,or Optional adapters and wire guards: 4"square standard electrical box.The cover can be • Wall mount A/V adapters are available to cover surface quickly removed(a tool is required)and covers are mounted electrical boxes and to adapt to Simplex® available separately for color conversion. 2975-9145 boxes Ceiling mount A/Vs install using standard 4"electrical • UL listed red wire guards are available for wall or boxes.Color choice is determined by model number. ceiling mount A/Vs Visible notification appliance(strobe): Strobe Intensity Selection • 24 VDC xenon strobe; intensity is selectable as 15,30, During installation,a selection plug at the back of the 75,or 110 candela with visible selection jumper secured housing determines the desired strobe intensity.An behind strobe housing attached flag with black letters on a highly visible yellow • UL listed to Standard 1971 background allows the selected intensity to be seen at the • Regulated circuit design ensures consistent flash output side of the strobe lens. and provides controlled inrush current * This product has been approved by the California State Fire Marshal(CSFM)pursuant to Section 13144.1 of the California Health and Safety Code.See CSFM Listing Audible notification appliance(horn): 7125-0026:317 for allowable values and/or conditions concerning material presented in this • Low current,24 VDC electronic horn with harmonicallydocument.Accepted for use—City of New York Department of Buildings—MEA35-93E. Refer to page 2 for listing status of wire guards.Additional listings may be applicable; rich sound output suitable for either steady or coded contact your local Simplex product supplier for the latest status.Listings and approvals operation(Temporal or 60 BPM March Time pattern) under Simplex Time Recorder Co.are the property of Tyco Fire Protection Products. • UL listed to Standard 464 S4906-0002-6 11/2014 Strobe Application Selection SmartSync Two-Wire Control Proper selection of visible notification is dependent on SmartSync operation mode allows a two-wire circuit to occupancy,location,local codes,and proper applications provide the ability to activate both the horn and strobe on of:the National Fire Alarm Code(NFPA 72),ANSI the same NAC and then allow the horn to be silenced A117.1;the appropriate model building code:BOCA, while the strobe remains flashing.The horn operates as ICBO,or SBCCI;and the application guidelines of the "on-until-silenced"while the strobe operation is Americans with Disabilities Act(ADA). "on-until-reset." Synchronized Strobes SmartSync Control Sources Multiple Strobes.When multiple strobes and their • 4006,4007ES Hybrid,4008,4010,4010ES,4100ES, reflections can be seen from one location,synchronized and 41000 Fire Alarm Control Panels(refer to flashes reduce the probability of photo-sensitive reactions individual product data sheets for more information) as well as the annoyance and possible distraction of • 4009 ZDNet NAC Extender(refer to data sheet random flashing.The multi-candela strobes of these A/Vs S4009-0002) are synchronized by the controlling SmartSync operation • SmartSync Control Module(SCM)4905-9938(refer to NAC. data sheet S4905-0003) Additional SmartSync compatible notification appliances include separate horns and combination Product Selection horn/strobe notification appliances. Multi-Candela A/Vs Model Mounting Housing Color "FIRE"Lettering Description 4906-9127 Red White 4906-9129 Wall White Red Horn with Multi-Candela Strobe;strobe intensity selectable as: 15, 30,75, or 110 candela;operates with SmartSync two-wire 4906-9128 Red White control 4906-9130 Ceiling White Red Wall Mount AN Accessories Model Description Dimensions 4905-9937 Red Surface Mount Adapter Skirt; use to cover 1-1/2"(38 mm)deep 5-3/8"H x 5-1/4"W x 1-5/8"D surface mounted boxes (136 mm x 133 mm x 41 mm) 4905-9940 White depth with strobe=4-3/8"(111 mm) 4905-9931 Red Adapter Plate for mounting to Simplex 2975-9145 box(typically for 8-5/16"x 5-3/4"x 0.060"Thick retrofit, may be mounted vertical or horizontal) (211 mm x 146 mm x 1.5 mm) 2975-9145 Red Mounting Box, requires Adapter Plate 4905-9931 7-7/8"x 5-1/8"x 2-3/4"D (200 mm x 130 mm x 70 mm) Optional Sound Damper;package of 20;field installed adhesive backed 4905-9838 horn output attenuator; reduces output 5 to 6 dBA 1-3/4"Diameter(44.5 mm) NOTE:After Sound Damper installation,measure sound level to ensure with 0.31"(8 mm)sound opening compliance with applicable code requirements SmartSync Control Module Model Description Dimensions 4905-9938 SmartSync Control Module with Class B or Class A output; mounts in 4" 4"x 4-1/8"x 1-1/4"D (102 mm)square box; refer to data sheet S4905-0003 for details (102 mm x 105 mm x 32 mm) Replacement Covers for Wall Mount ANs Model Description Dimensions 4905-9994 Red cover with white"FIRE"lettering 5-1/8"H x 5"W x 1-1/2"D 4905-9995 White cover with red"FIRE"lettering (130 mm x 127 mm x 38 mm) Wire Guards and Ceiling Mount AN Adapter Model Description Dimensions 4905-9961* Wall mount red wire guard with mounting plate,compatible with semi-flush 6-1/16"H x 6-1/16"W x 3-1/8"D or surface mounted boxes (154 mm x 154 mm x 79 mm) 4905-9927* Red Wire Guard for mounting to flush mounted electrical box 8-1/2"x 6-1/8"x 3" (216 mm x 156 mm x 76 mm) 4905-9928* Ceiling Red Adapter Plate, required to mount guard to surface 9"x 7" Mount mounted electrical box (229 mm x 178 mm) 4905-9915 White Surface Mount Adapter Box Extension, use to cover 4-3/4"x 6-7/8"x 1-1/2"deep, 4905-9916 Red 1-1/2"deep surface mounted boxes (121 mm x 175 mm x 38 mm) UL listed by Space Age Electronics Inc. 2 S4906-0002-6 11/2014 A/V S•ecifications Wall Mount or Ceiling Mount,Common Specifications Rated Voltage Range UL Listed Rating Regulated 24 DC;see Note 1 below ULC Listed Rating 20 VDC to 30 VDC per ULC S526-M878 Flash Rate and Synchronized NAC Loading 1 Hz;with up to 35 synchronized strobes maximum per NAC Environmental;Temperature and Humidity 32°to 122°F(0°to 50°C); 10%to 93%,non-condensing at 100°F(38°C) Connections Terminal blocks for 18 AWG to 12 AWG(0.82 mm2 to 3.31 mm2);two wires per terminal for in/out wiring Horn Output Characteristics 2400 to 3700 Hz sweep, modulated at 120 Hz rate Horn Output Voltage 16 VDC 24 VDC 33 VDC Ratings Sound Type(see Note 2) Steady Coded Steady Coded Steady Coded @ 10 ft(3 m) UL 464 Reverberant Chamber 86 dBA 82 dBA 88 dBA 84 dBA 90 dBA 86 dBA (see Note 2) Anechoic Chamber 92 dBA 91 dBA 94 dBA 95 dBA 96 dBA 96 dBA Housing Dimensions(with lens) 5-1/8"H x 5"W x 2-3/4"D(130 mm x 127 mm x 70 mm) Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Wall Strobe Setting(see Note 3 below) 75 mA 116 mA 221 mA 285 mA Mount Reference RMS Currents 18 VDC 67 mA 103 mA 196 mA 253 mA at other voltages 24 VDC 50 mA 77 mA 147 mA 190 mA Housing Dimensions(with lens) 4-3/4 L"x 6-7/8"W x 2-5/8"D(121 mm x 175 mm x 67 mm) Ceiling Maximum RMS Current Rating per 15 cd 30 cd 75 cd 110 cd Mount Strobe Setting(see Note 3 below) 86 mA 132 mA 250 mA 320 mA Reference RMS Currents 18 VDC 76 mA 117 mA 222 mA 284 mA at other voltages 24 VDC 57 mA 88 mA 167 mA 213 mA NOTES: 1. "Regulated 24 DC"refers to the voltage range of 16 to 33 VDC per UL Standard 1971,Signaling Devices for the Hearing Impaired.This voltage range is the absolute operating range.Operation outside of this range may cause permanent damage to the appliance. Please note that 16 VDC is the lowest operating voltage that is allowed at the last appliance on the NAC under worst case conditions. 2. Coded values are typical of the output measured with a Temporal coded or a March Time coded pulse and with a sound level meter reading on a"fast"setting.Under the same test conditions,coded horn output"peak"sound level readings are typically 4 dBA higher. Anechoic horn output ratings are typically more representative of actual installed sound output. 3. Currents are with horn on steady.The maximum RMS current listed is the device nameplate rating.Strobe designs are constant wattage and the maximum RMS current rating occurs at the lowest allowable operating voltage.(RMS is root mean square and refers to the effective value of a varying current waveform.) Installation Reference Surface or Semi-Flush Mountin• AElm INE iMounting is compatible with single gang,double gang,and / 0 4"(102 mm)square boxes, / 0 ( 1 I IMPORTANT!WALL MOUNT 1-1/2"(38 mm)deep,by others�_� INSTALLATION HEIGHT REFERENCE Optional 4905-9838 ��� a�� — 71 Sound tte Damper,nid 5 to 6 dBA !grim I • Bottom of lens to attenuate sound 5 to 6 dBA is either even iimio I with,or slightly Electrical worm O above bottom box outline Wiring access hole — � y� y Fai/Ark- ' ' ! of compatible 0❑ 0 I © boxes Wiring terminals for I- u O ;- II IIILOJ I SmartSync operation ,.1� ,,,,,-,4-7711li i• Mounting Holes: 4"square(a) Single gang(2) NFPA 72 requires 80"(2.03 m) �°°°m°°°'°" ,.,,,--7-:-",A,_ell9that the entire lens minimum I 1471"1.40 �� Double gang(3) be not less than 11101/r 80"and not greater than 96"above the Transparent housing finished floor and lens assembly Intensity selection plug,accessible only from rear of housing; frill ® F [1 n E factory setting is 15 cd Removable cover Strobe intensity (tool required) viewing slot 3 S4906-0002-6 11/2014 Ceiling Mount A/V and Guard Installation Reference Ceiling reference, 4"(102 mm)square box, Optional 4905-9928 Adapter Plate, surface mounted box 1-1/2"(38 mm)minimum depth required for surface mounted electrical box Four mounting clamps included,two each side 1 • 1 _4 _ —�...-�r,�r_�� T-moi1 C Ceiling reference, I� � +I�I�I�La I flush mounted boxII :� WI 4905-9915/-9916 Adapter, recommended for surface mounted box -— Wiring terminals are Optional 4905-9927 located behind the housing Red Wire GuardP All) 0 — 1 F' i " E End View eV liMil Strobe intensity viewing slot Intensity selection plug, acceessibleeonlyyfrommrear of lens housing;factory setting is 15 cd Wall Mount Installation Reference; Adapter Plate, Guard, and Adapter Skirt Surface Mounting Reference 2975-9145 Box with Optional Adapter Skirt and Optional Wire Guard MIN= o Surface mount conduit and 0 MEIN box shown for reference —_�_ ��� 4"(102 mm)square Ilia i , IIrearl=IIII�I111 ..~..-. sem■ box profile, 1-1/2" �; '- fIiuhlIiIiIIIhI S II I (38 mm)deep ®I�II -, I 1 IZ������L�����h I O 0 I 4905-99611II' -._.— Mil I Wire Guard EE Arlii AN WitoR=,I FORS ILS 4905 9931 Adapter Plate — I► =t Optional Surface Mount Adapter Skirt, O 4905-9961 Optional Wire Guard 1-1/2"deep:4905-9937,Red; (shown here for reference only, 4905-9940,White(conduit knockouts 4905-9931 Adapter Plate can be used on other mounting options) are provided on all four sides) TYCO,SIMPLEX,and the product names listed in this material are marks and or registered marks.Unauthorized use is strictly prohibited.NFPA 72 and National Fire Alarm and Signaling('ode are registered trademarks of the National Fire Protection Association(NEPA). B®S i rn p I ex Tyco Fire Protection Products•Westminster,MA•01441-0001•USA S4906-0002-6 11/2014 www.simplex-fire.com t,2014 Tyco Fire Protection Products.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice. Simplex System Accessories UL Listed* 4081 Series End-of-Line Resistor Harnesses Features For use as Class B end-of-line resistor: • Connect these resistor harnesses where end-of-line resistors are required at remote locations to monitor wiring continuity • Refer to specific circuit specifications for end-of-line resistor requirements UL Listed to Standard 864 Product Selection -9-1/2" (241 mm) Model Reference Description** Number 4081-9001 733-892 2.2 kQ, 1/2 W 4081-9002 733-893 3.3 1(12, 1 W 4081-9003 733-896 4.7 kO, 1/2 W 4081-9004 733-886 6.8 kS2, 1/2 W 4081-9005 733-984 1.8 kS2, 1/2 W 4081-9006 733-890 560 0, 1 W 4081-9007 733-891 1.2 ku, 1 W 4081-9008 733-894 10 kO, 1/2 W 4081-9009 733-912 20 0, 1 W . 4081-9010 733-973 1 kf2, 1 W 4081-9011 733-974 100 S2, 1/2 W 4081-9012 733-985 22 kQ2, 1/2 W Typical 4081 Series Resistor Harness Assembly 4081-9013 734-086 4.99 kS2, 1/2 W, ± 1% (full size except for lead length) 4081-9014 734-092 2.4 kf2, 1/2 W 4081-9015 734-093 1.5 kS2, 1/2 W 4081-9016 734-149 150 k12, 1/2 W S•ecifications 4081-9017 734-171 3.9 kS2, 1 W 4081-9018 734-168 10 kS2, 1 W Overall Length Approximately 9-1/2"(241 mm) *±5%tolerance except as noted. Wire Length 7"(178 mm)± 1"(25 mm) Wire Size 18 AWG(0.82 mm2) Insulation 600 V, black Leads Stripped 0.5"(13 mm);tinned Resistor Resistor leads are crimped to wires Attachment and covered with heat shrink tubing *This product was not approved by ULC,FM,MEA(NYC),or CSFM as of document revision date.Additional listings may be applicable,contact your local Simplex®product supplier for the latest status.Listings and approvals under Simplex Time Recorder Co.are the property of Tyco Safety Products Westminster. S4081-0003 7/2004 Tyco,Simplex,and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U.S.and/or other countries. ®Simplex Tyco Safety Products Westminster•Westminster,MA•01441-0001•USA S4081-0003 7/2004 www.tycosafetyproducts-usa-wm.corn o 2004 Tyco Safety Products Westminster.All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice.