Loading...
Report (42) Northwest The Suppression, Inc. RECEIVED EQUIPMENT SUBMITTAL MAY 17 2017 CITY OF TIGARD FOR BUILDING DIVISION TIGARD APARTMENTS HOLLAND APARTMENT GROUP 13045 SW Scholls Ferry Road Tigard, OR 97008 10/29/16 l N P5.2cni7-e /$' I Lc-St./ fkwfrs 4Z Y 27_ x.U-7 /537 S Sw ttiewirs isz SYSTEM 4t-bS ani Fire Sprinkler Monitoring System r TZSc-- r �—CW � SG✓ A /77.44 CONTENTS /��oS Manufacturers Data Sheets '20 4b Fps 7 13 3S/ fit/ ft p1 ,f -4F-e F-P620 -456'7,7- (4A( t✓ ftead4s /ca /3 13s-sw j -f's •I5 I . "�17� 74 I . 7 jS G7./ l*wf s `22dC nZ �7 l3 .5 41 rra 3 8-S- sw ts / 1800 NW 1697.''Place Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured Northwest.Fre Suppression, Inc. EQUIPMENT LIST ITEM MODEL DESCRIPTION 1 NFW2-100 Fire Alarm Control Panel w/Communicator 2 IPGSM-4G Single or Dual Path Commercial Fire Communicator 3 FDU-80 Remote Annunciator 4 NOT-BG12LX Pull Station 5 NP-100 Addressable Photoelectric Smoke Detector w/base NDM-100 Addressable Duel Monitor Module 6 N100-ISO Isolation Module 1800 NW 169th Place Suite C600 • Beaverton, Oregon 97006 • 503-644-7720 • Fax 503-644-8289 www.nwfire.com CCB#088629 Licensed • Bonded • Insured DN-60602:A1 FireWarden-100-2(E) Rev 3 NOTIFIER® Intelligent Addressable FACP by Honeywell Addressable Fire Alarm Control Panel General The Notifier FireWarden-100-2 Rev 3(NFW2-100)with Version 5.0 firmware is a combination FACP(Fire Alarm Control Panel) and DACT(Digital Alarm Communicator/Transmitter)all on one circuit board.This compact intelligent addressable control panel has an extensive list of powerful features. The SLC(Signaling Line Circuit)of the FireWarden-100-2 Rev 3 operates using a Rapid Group Polling communication protocol technology that polls multiple devices simultaneously for a quicker device response time.This patented technology allows a fully-loaded panel with up to 198 devices to report an incident and activate the notification circuits in under 10 seconds. With this improved polling,devices can be wired on standard twisted, unshielded wire up to a distance of 10,000 feet. The's quick-remove chassis protects the electronics during con- struction. The backbox can be installed allowing field wiring to be pulled.When construction is completed,the electronics can be quickly installed with just two bolts. New features for Rev 3 with Version 5.0 firmware include removable terminal blocks, improved transient protection, addi- tional secondary ANN-BUS, and increased power for the reset- 2 table and remote sync outputs. s Available accessories include ANN-BUS devices as well as ACS LED, graphic and LCD annunciators, and reverse polarity/city box transmitter. The integral DACT transmits system status (alarms, superviso- ries, troubles, AC loss, etc.) to a Central Station via the public • Remote site or local USB port upload/download, using PS- switched telephone network.It also allows remote and local pro- Tools. gramming of the control panel using the PS-Tools Upload/Down- • Four(4) Style Y (Class B) NAC circuits, which can be con- load utility. In addition,the control panel may be programmed or verted to four (4) Style Z (Class A) circuits with optional interrogated off-site via the public switched telephone network. ZNAC-92 converter module. (Up to 6.0 amps total NAC Any personal computer with Windows®XP or greater, a corn- power when using optional XRM-24B.) patible modem, and PS-Tools—the Upload/Download software • Selectable strobe synchronization for System Sensor,Whee- kit—may serve as a Service Terminal.This allows download of lock,and Gentex devices. the entire program or upload of the entire program, history file, • Remote Acknowledge, Silence, Reset and Drill via address- waiktest data, current status and system voltages. The panel able monitor modules or FDU-80, N-ANN-80 or Legacy ACS can also be programmed through the FACP's keypad or via a Annunciators. standard PS-2 computer keyboard, which can be plugged • ANN-BUS for connection to following optional modules(cannot directly into the printed circuit board.This permits easy typing of be used if ACS annunciators are used): address labels and other programming information. Version 5.0 firmware supports the following: Primary and Sec –N ANN 80(-W)Remote LCD Annunciator ondary ANN-bus devices,NP-A100,USB port,NAC circuit diag- –N-ANN-I/O LED Driver nostics, a new report has been added to the walk-test that lists –N-ANN-S/PG Printer Module untested devices, new device types added: audio telephone –N-ANN-RLY Relay Module type code for NFV 25/50ZST,Photo Supervisory and auto-reset- –N-ANN-LED Annunciator Module table Drill(non-latching). –N-ANN-RLED Annunciator Module alarms only The FireWatch Series internet monitoring modules IPDACT-2 –ROME Relay Option Module Enclosure and IPDACT-2UD permit monitoring of alarm signals over the • Internet saving the monthly cost of two dedicated business tele ACS&Terminalmode Annunciators: phone lines. Although not required, the secondary telephone –ACS Annunciators:Up to 32 Legacy ACM Series annuncia- line may be retained providing backup communication over the tors (ACM-16AT or ACM-32 series). Cannot be used if public switched telephone line. ANN-BUS devices are used. NOTE: Unless otherwise specified, the term "FireWarden-100-2" –Terminal-mode Annunciators: Up to 32 Legacy FDU-80 is used in this document to refer to both the FireWarden-100-2 and annunciators. the FireWarden-100-2E FACPs(Fire Alarm Control Panels). Like- • EIA-232 printer/PC interface(variable baud rate)on main cir- wise, "NFW2-100"refers to NFW2-100E as well. cuit board,for use with optional UL-listed printer PRN-6. • Integral 80-character LCD display with backlighting. Features • Real-time clock/calendar with automatic daylight savings • Listed to UL standard 864,9th edition. control. • On-board DACT. • Detector sensitivity test capability(NFPA 72 compliant). DN-60602:A1•12/07/2010—Page 1 of 6 • History file with 1,000-event capacity. • Ground Fault(yellow) • Maintenance alert warns when smoke detector dust accumu- KEYPAD CONTROLS lation is excessive. • Automatic device type-code verification. • Acknowledge/Step • One person audible or silent walk test with walk-test log and • Alarm Silence printout. • Drill • Point trouble identification. • System Reset(lamp test) • Waterflow(nonsilenceable)selection per monitor point. • 16-key alpha-numeric pad(similar to telephone keypad) • System alarm verification selection per detector point. • 4 cursor keys • PAS(Positive Alarm Sequence)and presignal delay per point • Enter (NFPA 72 compliant). NOTE:Only detectors may participate in PAS. Product Line Information SLC LOOP: NFW2-100: Fire Warden-100-2 Rev 3 198-point addressable • SLC can be configured for NFPA Style 4,6,or 7 operation. Fire Alarm Control Panel, one SLC loop. Includes 80-character • SLC supports up to 198 addressable devices per loop (99 LCD display, single printed circuit board mounted on chassis, detectors and 99 monitor,control,or relay modules). and cabinet. 120 VAC operation. • SLC loop maximum length 10,000 ft.(3,000 m.). NFW2-100R:Same as NFW2-100,except in a red backbox. See installation manual for wire tables. NFW2-100E: Same as NFW2-100,except with 240 VAC opera- NOTIFICATION APPLIANCE CIRCUITS(NACS): tion. 4XTM Reverse Polarity Transmitter Module: Provides super- • Four onboard NACs with additional NAC capability using out-put control modules (NC-100). The four Class B NACs can vised output for local energy municipal box transmitter, alarm, and trouble. be converted to four Class A NACs with optional ZNAC-92 converter module. ZNAC-92: Optional converter module which converts four (4) • Silence Inhibit and Auto Silence timer options. Style Y(Class B) NAC circuits to four(4) Style Z(Class A)cir- cuits. • Continuous, March Time, Temporal or California code for main circuit board NACs with two-stage capability. PS Tools: Programming software for Windows®-based PC Selectable strobe synchronization per NAC. computer(cable not included),available on www.firelite.com. •• 2.5 amps maximum per each NAC circuit. DP-9692B:Optional dress panel for FireWarden-100-2 Rev 3. NOTE:Maximum 24VDC system power output is shared among TR-CE-B:Optional trim Ring for semi flush mounting. all NAC circuits and 24VDC special-application auxiliary power BB-26: Battery backbox, holds up to two 26 AH batteries and outputs. Total available output is 3.0 amps. Using the optional CHG-75. XRM-24B transformer increases 24VDC output to 6.0 amps. NFS-LBB:Battery box,houses two 55 AH batteries. PROGRAMMING AND SOFTWARE: CHG-75: Battery charger for lead-acid batteries with a rating of • Autoprogram(learn mode)reduces installation time. 25 to 75 AH. • Custom English labels (per point) may be manually entered CHG-120: Remote battery charging system for lead-acid batter- or selected from an internal library file. ies with a rating of 55 to 120 AH. Requires additional NFS-LBB • Three Form-C relay outputs(two programmable). for mounting. • 99 software zones. NOTE: CHG-120 or CHG-75 required for batteries larger than Continuous fire protection during online programming at the 18AH. • front panel. BAT Series:Batteries,see data sheet DN-6933. • Program Check automatically catches common errors not XRM-24B(E): Optional transformer. Increases system power linked to any zone or input point. output to 6.0 amps. Use XRM-24BE with FireWarden-100-2E • OFFLINE PROGRAMMING: Create the entire program in Rev 3. your office using a Windows®-based software package PRT/PK-CABLE: Cable printer/personal computer interface (NFW2-100 requires PS-Tools Programming software, avail- cable;required for printer or for local upload/download program- able on www.magni-fire.com).Upload/download system pro- ming and updating panel firmware. gramming locally to the NFW2-100 Rev 3 in less than one PRN-6: UL listed compatible event printer. Uses tractor-fed minute. paper. • USB upload/download programming with standard Male-A to IPDACT-2/2UD, IPDACT Internet Monitoring Module: Mounts Male-B cable. in bottom of enclosure with optional mounting kit(PN IPBRKT). Connects to primary and secondary DACT telephone output User Interface ports for internet communications over customer provided ether- netLED INDICATORS Internet connection. Requires compatible Teldat VisorALARM Central Station Receiver.Can use DHCP or static • AC Power(green) IR.(See data sheet DN-60408 for more information.) • Fire Alarm(red) IPBRKT:Mounting kit for IPDACT-2/2UD in common enclosure. • Supervisory(yellow) IPSPLT:Y-adaptor option allows connection of both panel dialer • Alarm Silenced(yellow) outputs to one IPDACT-2/2UD cable input. • System Trouble(yellow) COMPATIBLE ANNUNCIATORS • Maintenance/Presignal(yellow) N-ANN-80(-W): LCD Annunciator is a remote LCD annunciator • Disabled(yellow) that mimics the information displayed on the FACP LCD display. • Battery Fault(yellow) Recommended wire type is un-shielded. (Basic model is black; order-W version for white;see DN-7114.) Page 2 of 6—DN-60602:A1•12/07/2010 N-ANN-LED:Annunciator Module provides three LEDs for each Appliance Circuit option requires external 24 VDC to power noti- zone: Alarm, Trouble and Supervisory. Ships with red or black fication appliances. enclosure(see DN-60242). NC-100R: Addressable relay module containing two isolated N-ANN-RLED:Provides alarm(red)indicators for up to 30 input sets of Form-C contacts, which operate as a DPDT switch. zones or addressable points.(See DN-60242). Mounts directly to a 4.0" (10.16 cm.) box, surface mount using N-ANN-RLY: Relay Module, which can be mounted inside the the SMB500. cabinet, provides 10 programmable Form-C relays. (See DN- NOT BG12LX: Addressable manual pull station with interface 7107.) module mounted inside. ROME-B: Relay Option Module Enclosure (order ROME-B for N100-ISO: Fault Isolator Module.This module isolates the SLC black or ROME for red). Provides one N-ANN-RLY Relay Mod- loop from short circuit conditions(required for Style 6 or 7 oper- ule already installed. The ROME Series provides mounting ation). space for one additional Relay Module or one addressable Multi- SMB500:Used to mount all modules except the NMM-100P. module. (See Installation Sheet PN 53530.) NMM-100-10: Ten-input monitor module. Mount one or two N-ANN-S/PG: SeriaVParallel Printer Gateway module provides modules in a BB-XP cabinet(optional).Mount up to six modules a connection for a serial or parallel printer.(See DN-7103.) on a CHS-6 chassis in a BB-25. N-ANN-VO: LED Driver Module provides connections to a user NZM-100-6: Six-zone interface module for compatible conven- supplied graphic annunciator.(See DN-7105.) tional two-wire detectors.Mount one or two modules in a BB-XP ACM-8R:Relay module provides 8 Form-C 5.0 amp relays. cabinet(optional).Mount up to six modules on a CHS-6 chassis ACM Annunciator Series: LED-type fire annunciators capable in a BB-25. of providing up to 99 software zones of annunciation.Available NOTE:For more information on Compatible Addressable Devices in increments of 16 or 32 points to meet a variety of applications. for use with the Fire Warden-100-2 Rev 3, see the following data LDM Graphic Series: Lamp Driver Module series for use with sheets(document numbers):N100-IS0(DN-6994),NP-100 series custom graphic annunciators. (DN-6995),NI-100(DN-6996), NH-100 series(DN-6997),ND-100 series (DN-7006), NP A100 (DN-6998), NMM-100/NMM-100P/ FDU-80(Liquid Crystal Display)point annunciator:80-char- NDM-100/NZM-100 (DN-6999), NC-100/NC-100R (DN-7000), acter, backlit LCD-type fire annunciators capable of displaying NOT-BG12LX (DN-7001), NMM-100-10 (DN-6990), and NZM- English-language text. 100-6(DN-60150). NOTE:For more information on Compatible Annunciators for use with the Fire Warden-100-2 Rev 3, see the following data sheets Wiring Requirements (document numbers)ACM-8R(DN-3558),ACS/ACM Series(DN- 0524),LDM Series(DN-0551),FDU-80(DN-6820). While shielded wire is not required, it is recommended that all SLC wiring be twisted-pair to minimize the effects of electrical COMPATIBLE ADDRESSABLE DEVICES interference.Wire size should be no smaller than 18 AWG(0.78 All feature a polling LED and rotary switches for addressing. mm2) and no larger than 12 AWG (3.1 mm2). The wire size depends on the length of the SLC circuit. Refer to the panel NI-100:Addressable low-profile ionization smoke detector. manual for wiring details. NP-100:Addressable low-profile photoelectric smoke detector. NP-100T:Addressable low-profile photoelectric smoke detector with thermal sensor. NP-100R: Addressable remote test capable detector for use with DNR(W)duct smoke detector housings. NH-100:Fast-response,low-profile heat detector. NH-100R: Fast-response, low-profile heat detector with rate-of- rise option. NH-100H: Fixed high-temperature detector that activates at 190F/88C. NP-A100:Addressable low-profile multi-sensor detector. DNR: Innovair Flex low-flow non-relay duct-detector housing. Order NP-100R separately. DNRW: Innovair Flex low-flow non-relay duct-detector housing, with NEMA-4 rating. Watertight.(Order NP-100R separately.) NMM-100: Addressable Monitor Module for one zone of nor- mally-open dry-contact initiating devices. Mounts in standard 4.0"(10.16 cm.)box.Includes plastic cover plate and end-of-line resistor.Module may be configured for either a Style B(Class B) or Style D(Class A)IDC. NDM-100: Dual Monitor Module. Same as NMM-100 except it provides two Style B(Class B)only IDCs. NMM-100P: Miniature version of NMM-100. Excludes LED and Style D option.Connects with wire pigtails.May mount in device backbox. NZM-100: Similar to NMM-100, but may monitor up to 20 con- ventional two-wire detectors. Requires resettable 24 VDC power.Consult factory for compatible smoke detectors. NC-100: Addressable Control Module for one Style Y/Z (Class B/A) zone of supervised polarized Notification Appliances. Mounts directly to a 4.0" (10.16 cm.) electrical box. Notification DN-60602:A1•12/07/2010—Page 3 of 6 FireWarden-100-2 Rev 3 Nil f Fire Alarm Control/ ANN-BUS Communicator or ANN-BUS DEVICES EIA-485 N-ANN-80,N-ANN-LED, in ACS modePi' 1.11 I I ,f) N-ANN-S/PG,N-ANN-I/O (two wires) SMOKE DETECTORS NP-100,NP-100T, 24 VDC k .-i~ ,_„ NI-100,NP-A100 I 1- .1 I Optional I. mini UM 4 REVERSE =v 1131111 POLARITY/ HEAT DETECTORS MIR o= CITY BOX NH-100,NH-100R,NH-100H :o off OUTPUT WI Er. (4XTM" ��— M0 UM —► 0 11111 111 Ic, ANNUNCIATORS — cp ACS/ACM,LDM 8 FORM-C,5-AMP RELAYS DUCT DETECTORS NOTE:System can use (optional,order ACM-8R) ND-100,ND-100R,DNR either ANN-BUS devices OR ACS-mode annunciators. ito oe0 They cannot be used simultaneously. NACs(Notification ► ; Appliance Circuits) o ► BELLS,SIGNALS,STROBES MONITOR/CONTROL NMM-100,NZM-100, NDM-100,N100-ISO, EIA-232 NC-100,NC-100R INTERFACE (PIM-24)built into the motherboard 0 ► 11111 11111 _-� ®00000 =� MULLE MULTI-MODULE PRINTER NZM-100-6,NMM-100-10 NOTE:System can use either the printer OR the FDU-80. They ,,g ww% cannot be used simultaneously. - EIA-485 ► INTERFACE 24 VDC „ „ (four wires) MINI-MONITOR NMM-100P LOCO = ' ' FIRE FDU-80 0.Up to 6,000 ft.(1825.8 m) s between each FDU-80 in . o the EIA-485 loop,and between PULL STATION g each FDU-80 and the FACP. NOT-BG12LX Page 4 of 6—DN-60602:A1•12/07/2010 DN-60602:A1•12/07/2010—Page 5 of 6 SYSTEM SPECIFICATIONS System Capacity (42.29 cm.)wide x 5.20" (13.34 cm.)deep.Trim Ring(TR-CE- • Intelligent Signalling Line Circuits 1 B):22.00"(55.88 cm.)high x 19.65"(49.91 cm.)wide. • Addressable device capacity 198 Shipping Specifications • Programmable software zones 99 • ACS Annunciators 32 Weight: 26.9 lbs. (12.20 kg.) Dimensions: 20.00" (50.80 cm.) high x 22.5"(57.15 cm.)wide x 8.5"(21.59 cm.)deep. • ANN-bus devices 16 Electrical Specifications Temperature and Humidity Ranges This system meets NFPA requirements for operation at 0 — AC Power: FireWarden-100-2 Rev 3: 120 VAC, 60 Hz, 3.0 49°C/32—120°F and at a relative humidity 93%±2%RH(non- amps. FireWarden-100-2 Rev 3(E):240 VAC,5 0 Hz, 1.5 amps. condensing) at 32°C ± 2°C (90°F± 3°F). However, the useful Wire size:minimum 14 AWG(2.00 mm2)with 600 V insulation. life of the system's standby batteries and the electronic compo- Battery charger capacity:7 AH-18 AH batteries.Up to two 18 nents may be adversely affected by extreme temperature ranges Ah batteries can be housed in the FACP cabinet. Larger batter- and humidity. Therefore,it is recommended that this system and ies require an external battery charger such as the CHG-75 or its peripherals be installed in an environment with a normal room CHG-120,and a separate battery cabinet such as the BB-26 or temperature of 15—27°C/60—80°F. NFS-LBB. Communication Loop:Supervised and power-limited. NFPA Standards Notification Appliance Circuits: Each terminal block provides The FireWarden-100-2 Rev 3 complies with the following NFPA connections for two Style Y(Class B)for a total of four Style Y 72 Fire Alarm Systems requirements: (Class B)or with an optional ZNAC-92 module converts to four —LOCAL (Automatic, Manual, Waterflow and Sprinkler Style Z(Class A) NACs. Maximum signaling current per circuit: Supervisory). 2.5 amps. End-of-Line Resistor:4.7K ohm, 1/2 watt(P/N 71252 UL listed)for Style Y(Class B)NAC. Refer to panel documenta- —AUXILIARY (Automatic, Manual and Waterflow) (requires tion and Notifier Device Compatibility Document for listed corn- 4XTM). patible devices. —REMOTE STATION (Automatic, Manual, Waterflow and Two Programmable Relays and One Fixed Trouble Relay: Sprinkler Supervisory)(Where a DACT is not accepted,the Contact rating:2.0 amps 30 VDC(resistive),0.5 amps 30 alarm,trouble and supervisory relays may be connected to VAC(resistive).Form-C relays. UL 864 listed transmitters. For reverse polarity signaling of alarm and trouble,4XTM is required.) Special Application Non-resettable Power (24 VDC Nomi- —PROPRIETARY (Automatic, Manual, Waterflow and Sprin- nal):Jumper selectable(JP4)for conversion to resettable power kler Supervisory). output. Up to 1.0 amp total DC current available from each out- put.Power-limited. —CENTRAL STATION (Automatic, Manual, Waterflow and Special Application Resettable Power (24 VDC nominal): Sprinkler Supervisory). Jumper selectable(JP6)for conversion to non-resettable power. —OT,PSDN(Other Technologies, Packet switched Data Net Up to 1.0 amp total DC current available. Refer to the Notifier work) Device Compatibility Document for listed compatible devices. Remote Sync Output: Remote power supply synchronization Agency Listings and Approvals output. Nominal special application power: 24 VDC. Maximum The listings and approvals below apply to the basic FireWarden- current:300 mA. End-of-Line Resistor:4.7K ohm.Output linked 100-2 Rev 3 control panel.In some cases,certain modules may to NAC 1 control.Supervised and power-limited. not be listed by certain approval agencies, or listing may be in Telephone Interface: Unless used with Teldat VISORALARM, process.Consult factory for latest listing status. requires dedicated business telephone number with a minimum • UL Listed:S635 of 5 volts DC (off-hook voltage). Obtain dedicated phone line • FM approved directly from your local phone company. Do not use shared phone lines or PBX(digital)type phone line extensions. • CSFM:7165-0028:0235 • MEA: 120-06-E,Volume 2 Cabinet Specifications For ULC-listed version,see DN-60600. Door: 19.26"(48.92 cm.)high x 16.82"(42.73 cm.)wide x 0.12" (.30 cm.) deep. Backbox: 19.00" (48.26 cm.) high x 16.65" NOTIFIER® is a registered trademark of Honeywell International Inc. Wheelock®is a registered trademark of and ExcederTM is a trademark of Cooper Notification. 02010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. E R T F E D We cannot cover all specific applications or anticipate all requirements. MONIS i MND All specifications are subject to change without notice. !MALITT SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 6 of 6—DN-60602:A1•12/07/2010 Honeywell IPGSM-4G Single or Dual Path Commercial Fire Communicator 1110111.411*11.** General The IPGSM-4G is a commercial fire alarm communicator that offers contact ID reporting with any Fire Alarm Control Panel •-•-• (FACP)that has a built-in dialer.This single or dual path com- municator connects directly to the primary and secondary communication ports of a fire panel's Digital Alarm Communi- cator Transmitter (DACT). It offers three selectable reporting paths which include: Cellular only, IP only, or IP primary/cellu- lar backup. All signals from the IPGSM-4G are delivered to Honeywell's AlarmNet Network Control Center, which routes highly encrypted Ethernet data packets via a customer pro- vided internet connection or cellular network to the appropriate central station. The state of the art AlarmNet network control center is fully redundant and monitored 24/7. AlarmNet has • Multi-GSM platform compatibility for 2G, 3G and 4G net- the ability to route messages using AlarmNet-I and 800 PLUS works. services, providing true redundancy and multipath message • delivery. Operates over the following communication protocols: HSPA+ (4G) HSPA (HSDPA & HSUPA) (3G) EDGE (2G) Alternative communication methods are critical in the market- GPRS(2G). place due to VolP(Voice over IP),migration from POTS(Plain • Selectable reporting paths and supervision intervals to Old Telephone Service) and growth of digital radio networks. meet NFPA 72, chapter 26 requirements. (Compliant with The IPGSM-4G's single path communications solution allows NFPA 72 2010 and 2013 supervision requirements.) one technology to be used(either IP or cellular)to provide the appropriate connectivity to a central station.For added reliabil- • Works over any type of customer provided Ethernet 10/100 ity, our exclusive dual path solution allows both technologies based network connection (LAN or WAN), DSL modem or (IP and cellular)to be used together for maximum survivability cable modem. or for local jurisdiction requirements that specify a dual tech- • Data transmits over standard contact-ID protocol but is nology system. secured with the industry's advanced encryption standard The IPGSM-4G is designed to operate over the most common (AES 256 bit). cellular networks including 2G,3G and 4G.Its multi-GSM plat- • Supports both dynamic(DHCP)or Public and Private Static form technology automatically chooses the best available cel- IP addressing. lular signal in the area based on signal strength and • Built-In Power Supply module: On board charging circuit seamlessly self-adjusts to maintain critical life safety communi- design accommodates back-up battery. Includes primary cation. In addition, it connects to any type of customer pro- power and battery supervision. vided Ethernet 10/100 base network connection (LAN or • Diagnostic LEDs:Signal strength and status indicators. WAN), DSL model or cable modem. Our selectable reporting • path feature allows the radio to be configured for a single or Reliable connection: IP and GSM connection tested every dual path solution as well as the appropriate supervision inter- day. vals based on NFPA 72 requirements. (See diagram below for • QOS: Quality of Service diagnostics via AlarmNet conveys selectable paths and supervision timing intervals.) vital communicator information including when message was received,signal strength,and message path used. • 7720P Hand-held programmer for easy setup. Selectable Path Description Supervision Times Operation 2010 GSM Single Path(cellular only) 5 minutes When an event occurs, the Fire Alarm Control Panel goes off 2010 IP Single Path(IP only) 5 minutes hook to dial the central station.The IPGSM-4G Dialer Capture Module detects the off-hook condition and provides the fire 2010 IP&GSM Dual Path(IP and cellular) 24 hours panel with a dial tone. When the fire panel detects the dial 2013 GSM Single Path(cellular only) 1 hour tone, it begins dialing the central station. After the dialing is completed,the Dialer Capture Module returns a handshake to 2013 IP Single Path(IP only) 1 hour the fire panel.The fire panel then sends the contact ID reports 2013 IP&GSM Dual Path(IP and cellular) 6 hours to the Dialer Capture Module, which in turn sends a kiss-off after the report is successfully received from the fire panel. The Dialer Capture Module sends the contact ID reports to the Features IPGSM communications module. When all the reports are • Saves the cost of two dedicated phone lines. sent, the fire panel goes on-hook. The IPGSM communica- Single or dual path communications. (Can communicate to tions module then transmits the messages to the central sta • central station using cellular technology, Internet or both. tion either over the GSM network or the Internet (dependent on configuration). • Requires no change to the existing Fire Alarm Control Panel configuration. (Connects directly to the primary and secondary telephone ports of a DACT.) Easy to Program -One 12 V 7.0 AH lead-acid battery(not supplied). The IPGSM-4G communicator can be pre-programmed using —Battery charging current: 1 Amp maximum. the 7720P programmer to enter all central-station information. —Battery discharge current: Standby 230mA, Active This is saved to the IPGSM-4G communicator panel memory. 950mA. When the IPGSM-4G communicator is installed at the site and connected to the Internet/Intranet, it registers itself with the Cabinet Specifications AlarmNet receiver. Dimensions: 14.875"H x 12.75"W x 3.0"D(37.8 cm H x 32.4 .For most installations,the only required parameters are: cm W x 7.6 cm D). • Primary City ID (two digits) obtained from your monitoring Color: Red. station. • Primary Central Station ID (two digits) obtained from your Shipping Specifications monitoring station. Weight:5.3 lbs.(6.94 kg). • Primary Subscriber ID(four digits)obtained from your mon- Dimensions: 15.625" H x 13.79" W x 9.25" D (39.7 cm H x itoring station. 34.9 cm W x 23.9 cm D) • Communication Module's MAC ID, and MAC CRC number located on outside of box,and inside of the module. Temperature and Humidity Ranges All of these parameters are assigned by the monitoring station. This system meets NFPA requirements for operation at 0 - NOTE: Some assembly is required. See Installation and Setup 49°C/32-120°F and at a relative humidity 93%±2%RH(non Guide#800-12454 for full details. condensing at 32°C ± 2°C (90°F± 3°F). However, the useful life of the system's standby batteries and the electronic com- Fire Communicator Capability ponents may be adversely affected by extreme temperature The IPGSM-4G is compatible with fire panels that use the ranges and humidity. Therefore, it is recommended that this Contact ID communications format as described in the SIA system and its peripherals be installed in an environment with DC-05 standard. a normal room temperature of 15-27°C/60-80°F. AlarmNet Product Line Information Honeywell's AlarmNet has been the nationwide leader in IPGSM-4G: Internet and Digital Cellular Fire Alarm Communi- alarm communications technology since 1986.A reliable alter- cator Panel. Includes red cabinet with Ademco key and lock, native for the transmission of alarm signals,our radio network wall outlet box,Dialer Capture Module,IGSM Communications provides extensive coverage in the United States and Canada. Module, antenna & mounting adapter, PowerBoostl power AlarmNet Network Control center processes signals from pow- supply, LED display board, transformer, manual, & required erful servers in multiple locations equipped with 24/7 infra- screws,cables,etc. structure support.The AlarmNet network consist of redundant Antenna Kits hardware servers, hot back-up databases and generators with GSM-ANT3DB25KT:25 ft.antenna kit.Includes GSM-ANT3DB, battery back-up at all locations to ensure continuity of service. WA7626-CA adapter cable,and a 25'RF cable. Signals from Alarm-Net are transmitted to the central station's GSM-ANT3DB5OKT:50 ft.antenna kit.Includes GSM-ANT3DB, receivers using multiple communications paths consisting of WA7626-CA adapter cable,and a 50'RF cable. the Internet,radio network or toll-free POTS service. Antenna External Hardware Installation Requirements GSM-ANT3DB:3db gain external/remote antenna. WA7626-CA:SNA to N Adapter. UL COMPLIANCE 7626-50HC:50 ft.antenna cable,low loss. To meet UL864/NFPA,ensure the following: 7626-25HC:25 ft.antenna cable,low loss. • IPGSM-4G must be installed in accordance with NFPA NOTE: The GSM-ANT3DB and the WA7626-CA are both required (National Fire Protection Association)standards 70 and 72. for installing an external antenna along with the necessary cable needed(7626-50HC:50 ft.or 7626-25HC:25 ft.) • IPGSM-4G must be mounted in the same room and within 20 feet of the fire panel. Other Accessories • IPGSM-4G, and all equipment used for the IP connection 7720P:IPGSM-4G hand held programmer. (such as the router,hub, modem,etc.)shall be listed, must HPTCOVER:Plug in transformer box for IPGSM communicator. be powered from an un-switched branch circuit,and be pro- BAT-1270: Battery 12 Volts,7 AH,sealed. vided with appropriate standby power. • IPGSM-4G must use the 7AH battery(not supplied)to pro- Agency Listings and Approvals vide 24-hour backup capability. The listings and approvals below apply to the basic IPGSM-4G communicator panel.In some cases,certain modules may not be Electrical Specifications listed by certain approval agencies,or listing may be in process. Transformer: Consult factory for latest listing status. —Primary 120VAC,60Hz,0.5A. UL Listed:S789. —Secondary: 18VDC,50VA. CSFM:7300-1645:0199. Battery: FDNY:COA#6150. Page 2 of 3—DH-60769:C•4/28/14 www.honeywell.com This document is not intended to be used for installation purposes.We try to keep our product information up-to-date and accurate.We cannot cover all specific applications or anticipate all requirements.All specifications are subject to change without notice. ©2014 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. Automation and Control Solutions Honeywell Honeywell 12 Clintonville Road 1(877)HPP-POWR Northford, CT 06472-1610 hpp_techserv@honeywell.com www.honeywellpower.com DH-60769:C April 2014 Made in the U.S.A. ' 9001 ®U.S.Registered Trademark ®2014 Honeywell International Inc. ME=SMMIALIIMM Page3of3 SSHLITT SYSTEMS DN-6820:B•D-123 FDU-80 80 Character Liquid Crystal Display ® NOTIFIER® by Honeywell Annunciators General The FDU-80 is a compact,cost-effective,80-character, backlit LCD remote Fire Annunciator for use with the NOTIFIERFire- Warden-100-2, NFS2-640, and NFS-320 Fire Alarm Control Panels(FACPs).The FDU-80 mimics the display of the control �'"�°`° °+' • panel and displays complete system point status information. r � Up to 32 FDU-80s may be connected onto the EIA-485 termi nal port of each FACP.The FDU-80 requires no programming, com:. which saves time during system commissioning. Features «..� • 80-character Liquid Crystal Display. • Mimics all display information from the host panel. • Control switches for System Acknowledge, Signal Silence, Drill and Reset with enable key. sezaaue.;pg • System status LEDs for Power,Alarm,Trouble,Supervisory and Alarm Silenced. • No programming necessary—FDU-80 connects to the ter Ordering Information minal porton the FACP. FDU-80:80 character,backlit, LCD Fire Annunciator with con- • Displays device type identifiers,individual point alarm,trou- trol switches for remote control of system functions, and key- ble or supervisory,zone and custom alpha labels. switch lock. • Time-and-date display field. FDU-80C: ULC-listed version;see DN-60573 for details. • Aesthetically pleasing design. 10103:Three-gang electrical box,minimum 2.188"(5.556 cm) • May be powered from the host FACP or by remote power deep,for semi-flush mount applications. supply(requires 24 VDC). SBB-3: Three-gang surface backbox for surface-mount appli- • Up to 32 FDU-80 annunciators per FACP. cations. • Plug-in terminal blocks for ease of installation and service. • Can be remotely located up to 6,000 feet (1828.8 m)from Agency Listings And Approvals the FACP. These listings and approvals apply tothe modules specified in • Local piezo sounder with alarm and trouble resound. this document. In some cases,certain modules or applications • Semi-flush mounts to 2.188" (5.556 cm) minimum deep, may not be listed by certain approval agencies, or listing may three-gang electrical box (NOTIFIER PN 10103) or three- be in process.Consult factory for latest listing status. gangable electrical switchbox. • UL Listed:S635 • Surface-mounts to NOTIFIER PN SBB-3 surface backbox. • MEA Listed:245-00-E • FDNY:COA#6038 Operation • CSFM:7120-0028:209 The FDU-80 annunciator provides the FACP with point annun- • FM Approved ciation with full display text on an 80-character LCD display. NOTE:For ULC-listed version,see DN-60573. The FDU-80 also provides an array of LEDs to indicate system status,and includes control switches for remote control of criti- cal system functions. The FDU-80 provides the FACP with up to 32 remote serially connected annunciators. All field-wiring terminations on the FDU-80 use removable, compression-type terminal blocks for ease of wiring and circuit testing. Communication between the FACP and the annunciators is accomplished over an EIA-485 serial interface, which greatly reduces wire and installation cost over traditional systems. Installation The FDU-80 can be semi-flush mounted to a 2.188" (5.556 cm) minimum deep, three-gang electrical box or three-gang- able electrical switchboxes. Alternately, an SBB-3 surface backbox is available for surface-mount applications. DN-6820:B•05/17/2010—Page 1 of 2 NOTIFIER®is a registered trademark of Honeywell International Inc. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. This document is not intended to be used for installation purposes. ISO9001 We try to keep our product information up-to-date and accurate. C E R T F 1 E O We cannot cover all specific applications or anticipate all requirements. MINIM 3MANINIIMMi All specifications are subject to change without notice. SUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6820:8.05/17/2010 DN-7001:D•A1-380 NOT-BG 12LXqD NOT 1 F 1 E R® Addressable Manual Pull Station by Honeywell Intelligent/Addressable Devices General The Notifier NOT BG12LX is a state-of-the-art, dual-action (i.e., requires two motions to activate the station) pull station that includes an addressable interface for FireWarden series intelligent control panels,and the NSP-25 panel. Because the NOT-BG12LX is addressable,the control panel can display the , .,.. exact location of the activated manual station. This leads fire personnel quickly to the location of the alarm. PUSH Features \4PuLLDC\r,' • Maintenance personnel can open station for inspection and address setting without causing an alarm condition. r; • Built-in bicolor LED, which is visible through the handle of — n the station,flashes in normal operation and latches steady red when in alarm. • Handle latches in down position and the word"ACTIVATED" appears to clearly indicate the station has been operated. • Captive screw terminals wire-ready for easy connection to rJ N�� SLC loop(accepts up to 12 AWG/3.25 mm2 wire). • Can be surface mounted (with SB-10 or SB-I/O) or semi flush mounted. Semi-flush mount to a standard single- gang,double-gang,or 4"(10.16 cm)square electrical box. • Smooth dual-action design. The NOT-BG12LX • Meets ADAAG controls and operating mechanisms guide- Addressable Manual Pull Station lines (Section 4.1.3[13]); meets ADA requirement for 5 lb. maximum activation force. • Highly visible. The BG12TR is usually needed for semi-flush mounting with 4" • Attractive shape and textured finish. (10.16 cm)or double-gang boxes(not with single-gang boxes). • Key reset. Operation • Includes Braille text on station handle. • Optional trim ring(BG12TR). Pushing in,then pulling down on the handle causes it to latch in the down/activated position. Once latched,the word"ACTI- • Meets UL 38, Standard for Manually Actuated Signaling VATED" (in bright yellow) appears at the top of the handle, Boxes. while a portion of the handle protrudes from the bottom of the station.To reset the station,simply unlock the station with the Construction key and pull the door open.This action resets the handle;clos- Shell, door, and handle are molded of durable polycarbonate ing the door automatically resets the switch. material with a textured finish. Each manual station, on command from the control panel, sends data to the panel representing the state of the manual Specifications switch.Two rotary decimal switches allow address settings (1 —99 on NFW2-100/NFW2-100C, 1 —50 for NFW-50/NFW- • Shipping Weight:9.6 oz.(272.15 g) 50C). • Normal operating voltage:24 VDC. • Maximum SLC loop voltage:28.0 VDC. Architectural/Engineering • Maximum SLC standby current:375 pA. Specifications • Maximum SLC alarm current:5 mA. Manual Fire Alarm Stations shall be non-coded, with a key- • Temperature Range:32°F to 120°F(0°C to 49°C) operated reset lock in order that they may be tested, and so • Relative Humidity: 10%to 93%(noncondensing) designed that after actual Emergency Operation, they cannot be restored to normal except by use of a key.An operated sta- • For use indoors in a dry location tion shall automatically condition itself so as to be visually detected as activated. Manual stations shall be constructed of Installation red-colored polycarbonate material with clearly visible operat- The NOT-BG12LX will mount semi flush into a single gang, ing instructions provided on the cover. The word FIRE shall double-gang,or standard 4"(10.16 cm)square electrical outlet appear on the front of the stations in white letters, 1.00 inches box, or will surface mount to the model SB-10 or SB-I/O sur- (2.54 cm) or larger. Stations shall be suitable for surface face backbox. If the NOT-BG12LX is being semi flush mounting on matching backbox SB-10 or SB-I/O;or semi-flush mounted, then the optional trim ring (BG12TR) may be used. mounting on a standard single gang, double-gang, or 4"(10.16 cm) square electrical box, and shall be installed DN-7001:D•4/13/2012—Page 1 of 2 within the limits defined by the Americans with Disabilities Act (ADA) or per national/local requirements. Manual Stations shall be Underwriters Laboratories listed. Manual stations shall connect with two wires to one of the con- trol panel SLC loops. The manual station shall, on command from the control panel,send data to the panel representing the state of the manual switch. Manual stations shall provide address setting by use of rotary decimal switches. Product Line Information NOT BG12LX: Dual-action addressable pull station. Includes key locking feature. (Listed for Canadian and non-Canadian applications.) SB-10:Surface backbox;metal. SB-UO:Surface backbox;plastic. BG12TR:Optional trim ring. 17021: Keys,set of two. Agency Listings and Approvals In some cases, certain modules or applications may not be listed by certain approval agencies, or listing may be in pro- cess.Consult factory for latest listing status. • UL/ULC Listed: S692 (listed for Canadian and non-Cana- dian applications). • MEA:67-02-E Vol. IV. • CSFM:7150-0028:0199. • FM Approved. Patented: U.S. Patent No. D428,351; 6,380,846; 6,314,772; 6,632,108. NOTIFIER®is a registered trademark of Honeywell International Inc. ©2012 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T F 1 E D We cannot cover all specific applications or anticipate all requirements. MEM=i IMAIUSIMINB All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-7001:D•4/13/2012 DN-6995:C•Al-320 NP-100(A) Series NOTIFIER® Addressable Photoelectric Detectors for the FireWarden Series by Honeywell Addressable General The NP-100(A), NP-100T(A) and NP-100R(A) addressable, low-profile plug-in photoelectric detectors use a state-of-the- art photoelectric sensing chamber with communications to provide open area protection and are used exclusively with NOTIFIER's FireWarden Series (FireWarden-100-2 and Fire- Warden-50) and Spartan (NSP-25) Addressable Fire Alarm Control Panels (FACPs). The NP-100T(A) adds thermal sen- sors that will alarm at a fixed temperature of 135°F (57°C). Since these detectors are addressable, they will help emer- gency personnel quickly locate a fire during its early stages, potentially saving precious rescue time while also reducing property damage.Two LEDs on each sensor light to provide a local,visible sensor indication.Remote LED annunciator capa- a bility is available as an optional accessory, PN RA100Z(A). The NP-100R(A)is a remote test capable detector for use with NP-100(A) in B210LP(A) Base DNR(A)/DNRW duct smoke detector housings. Features Applications SLC loop Use photoelectric detectors in life-safety applications to pro- • Two-wire loop connection. vide a broad range of fire-sensing capability,especially where • Unit uses base for wiring. smoldering fires are anticipated. Ionization detectors are often Addressing better than photoelectric detectors at sensing fast, flaming fires. • Addressable by device. • Rotary,decimal addressing:01 –99 with FireWarden-100-2 Construction and NSP-25,and 01 –50 with FireWarden 50. These detectors are constructed of off-white fire resistant plas- Architecture tic. NP-100(A) series plug-in, low-profile smoke detectors are • Unique single-source, dual-chamber design to respond designed to commercial standards and offer an attractive quickly and dependably to a broad range of fires. appearance. • Sleek,low-profile design. • Integral communications and built-in type identification. Installation • Built-in tamper-resistant feature. NP-100(A)series plug-in detectors use a detachable mounting • Removable cover and insect-resistant screen for simple base to simplify installation,service and maintenance. field cleaning. Mount base(all base types) on an electrical backbox which is Operation at least 1.5"(3.81 cm)deep.For a chart of compatible junction Withstands air velocities up to 4,000 feet-per-minute(20 m/ boxes,see DN 60054. • sec.)without triggering a false alarm. NOTE:Because of the inherent supervision provided by the SLC Factory preset at 1.5% nominal sensitivity for panel alarm loop, end-of-line resistors are not required. Wiring 'T--taps" or • branches are permitted for Style 4 (Class B) wiring. NP-100R(A) threshold level. mounts in a DNR(A)/DNRW duct detector housing. • Visible LED"blinks"when the unit is addressed (communi- cating with the fire panel)and latches on in alarm. Operation Mechanicals Each NP-100(A) series detector uses one of 99 possible • Sealed against back pressure. addresses on the FireWarden-100-2 and NSP-25,or one of 50 • Direct surface mounting or electrical box mounting. possible addresses on the FireWarden-50 Signaling Line Cir- • Mounts to: single-gang box, 3.5" (8.89 cm) or 4.0" (10.16 cuit (SLC). It responds to regular polls from the system and cm)octagonal box,or 4.0"(10.16 cm)square electrical box reports its type and status. (using a plaster ring—included). The addressable photoelectric sensor in the NP-100(A)series Other system features has a unique unipolar chamberthat responds quickly and uni- formly to a broad range of smoke conditions. It can withstand • Fully coated circuit boards and superior RF/transient pro- wind gusts up to 4,000 feet-per-minute (20 m/sec.) without tection. sending an alarm level signal. Because of its unipolar cham- • 94-VO plastic flammability rating. ber, the NP-100(A) series is approximately two times more • Low standby current. responsive than most photoelectric sensors. This makes it a Options more stable detector. • Remote LED output connection,PN RA100Z(A). DN-6995:C•12/07/2011—Page 1 of 2 Detector Sensitivity Test NP-100RA:Same as NP-100R with ULC Listing for use with a DNRA duct detector housing;B210LPA base included. Each detector can have its sensitivity tested (required per NFPA 72,Chapter 14 on Inspection, Testing and Maintenance) INTELLIGENT BASES when installed/connected to a FireWarden-100-2 or FireWar NOTE:"A"suffix indicates ULC Listed model. den-50 addressable fire alarm control panel.The results of the sensitivity test can be printed off the FireWarden-100-2 or Fire- NOTE:For details about intelligent bases and their mounting,see Warden-50 for record keeping. DN-60054. B210LP(A): Plug-in detector base (included); standard U.S. Specification flanged low-profile mounting base. Voltage range 15-32 VDC(peak). B210LPBP:Bulk pack of B210LP;package contains 10. Standby current:300 pA @ 24 VDC. B501(A):Standard European flangeless mounting base. LED current:6.5 mA 0 24 VDC(latched"ON"). B501BP:Bulk pack of B501;package contains 10. Air velocity:4,000 ft./min.(20 m/sec.)maximum. B200SR(A): Intelligent sounder base capable of producing sound output with ANSI Temporal 3 or continuous tone. Size:2.1"(5.33 cm)high;base determines diameter. Replaces B501 BH series bases in retrofit applications. -B210LP(A):6.1"(15.5 cm)diameter. B224RB(A): Plug-in System Sensor relay base. Screw termi- -B501(A):4.1"(10.4 cm)diameter. nals:up to 14 AWG(2.0 mm2).Relay type:Form-C.Rating:2.0 -B200SR(A):6.875"(17.46 cm)diameter. A o 30 VDC resistive; 0.3 A c 110 VDC inductive; 1.0 A o -B224RB(A):6.2"(15.748 cm)diameter. 30 VDC inductive. Weight 3.6 oz.(102 g). B224B1(A): Plug-in System Sensor Isolator detector base. Maximum 25 devices between isolator bases(see DN-6994). Operating temperature range: for NP-100(A):0°C to 49°C ACCESSORIES (32°F to 120°F); for NP-100T(A):0°C to 38°C(32°F to 100°F). NP-100R(A):installed in a DNR(A)/DNRW-20°C to 70°C(-4°F F110: Retrofit flange to convert B210LP(A) to match the to 158°F). B710LP(A) profile, or to convert older high-profile bases to Temperature:0°C-49°C(32°F-120°F) low-profile. Relative humidity: 10%-93%,non-condensing. F1106P:Bulk pack of F110;package contains 15. F210: Replacement flange for B210LP(A)base. Listings RA100Z(A): Remote LED annunciator.3-32 VDC. Mounts to Listings and approvals below apply to the NP-100(A), NP- a U.S. single-gang electrical box. For use with B501(A) and 100T(A), and NP-100R(A) detectors. In some cases, certain B210LP(A)bases only. modules may not be listed by certain approval agencies, or SMB600:Surface mounting kit listing may be in process. Consult factory for latest listing sta M02-04-00•Test magnet. tus. • UL Listed:S1115. M02-09-00:Test magnet with telescoping handle. • ULC Listed:S911. XR2B: Detector removal tool. Allows installation and/or removal of detector heads from bases in high ceiling applica- • CSFM:7272-0028:0231. tions. • MEA:243-02-E Vol.2. XP-4: Extension pole for XR2B. Comes in three 5-foot (1.524 • Maryland State Fire Marshal:permit 2173. m)sections. • FM approved. T55-127-010:Detector removal tool without pole. Product Line Information BCK-200B:Black detector covers for use with NP-100(A)only; box of 10. NOTE:"A"suffix indicates ULC Listed model. WCK-200B: White detector covers for use with NP-100(A) NP-100: Adressable photoelectric detector; B210LP base only;box of 10. included. NP-100A: Sames as NP-100 with ULC Listing;B210LPA base included. NP-100T: Same as NP-100 but with thermal element; B210LP base included. NP-100TA: Same as NP-100T with ULC Listing; B210LPA base included. NP-100R: Remote test capable addressable photoelectric NOTIFIER® and FireWarden® are registered trademarks of Honeywell detector for use with a DNRA/DNRW duct detector housing; International Inc. B210LP base included. ®2011. All rights reserved. Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. :::::::::;:� We try to keep our product information up-to-date and accurate. ::;� CER-ri F I E We cannot cover all specific applications or anticipate all requirements. BMWi MND All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2-DN-6995:C•12/07/2011 Monitor Modules DN-6999:C N MM-100(A), NMM-100P(A), NOT 1 F 1 ER® N ZM-100(A), and NDM-100(A) by Honeywell for FireWarden Series Panels Intelligent Addressable Devices General Four different monitor modules are available for Notifier's Fire- Warden Series intelligent control panels for a variety of appli- cations. Monitor modules supervise a circuit of dry-contact111111 input devices, such as conventional heat detectors and pull , 116 stations, or monitor and power a circuit of two-wire smoke """ .- detectors(NZM-100(A)). tailtlieekst team " NMM-100(A)is a standard-sized module(typically mounts to a 4" [10.16 cm] square box) that supervises either a Style D .1.11..•11 AU. (Class A) or Style B (Class B) circuit of dry-contact input 1115111 1-1 devices. le•w•�•1-�"`"" ', WPM TI NMM-100P(A) is a miniature monitor module a mere 1.3" '" (3.302 cm) H x 2.75" (6.985 cm) W x 0.5" (1.270 cm) D that supervises a Style B (Class B) circuit of dry-contact input NV VP devices. Its compact design allows the NMM-100P(A) to be mounted in a single-gang box behind the device it monitors. , NZM-100(A) is a standard-sized module that monitors and supervises compatible two-wire,24 volt,smoke detectors on a Style D(Class A) or Style B(Class B)circuit. NDM-100(A) is a standard-sized dual monitor module that NMM-100(A)(Type H) monitors and supervises two independent two-wire Style B (Class B) dry-contact initiating device circuits (IDCs) at two separate,consecutive addresses in intelligent,two-wire systems. NMM-100(A) OPERATION Each NMM-100(A) uses one of the available module N MM-100(A) Monitor Module addresses on an SLC loop. It responds to regular polls from • Built-in type identification automatically identifies this device the control panel and reports its type and the status(open/nor- as a monitor module to the control panel. mal/short)of its Initiating Device Circuit(IDC).A flashing LED indicates that the module is in communication with the control • Powered directly by two-wire SLC loop.No additional power panel. The LED latches steady on alarm (subject to current required. limitations on the loop). • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. NMM-100(A) SPECIFICATIONS • Direct Decade entry of address: 01 —99 on FireWarden- Nominal operating voltage: 15 to 32 VDC. 100-2,01 —50 on FireWarden-50. Maximum current draw:5.0 mA(LED on). • LED flashes during normal operation and latches on steady Average operating current: 350 NA (LED flashing), 1 corn- to indicate alarm. munication every 5 seconds,47k EOL. The NMM-100(A) Monitor Module is intended for use in intelli- Maximum IDC wiring resistance:40 ohms. gent, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It pro- EOL resistance:47K ohms. vides either a two-wire or four-wire fault-tolerant Initiating Temperature range:32°F to 120°F(0°C to 49°C). Device Circuit (IDC) for normally-open-contact fire alarm and Humidity range: 10%to 93%noncondensing. supervisory devices. The module has a panel-controlled LED indicator. Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x NMM-100(A)APPLICATIONS 2.125"(5.398 cm)deep box. Use to monitor a zone of four-wire smoke detectors, manual fire alarm pull stations, waterflow devices, or other normally- open dry-contact alarm activation devices. May also be used to monitor normally-open supervisory devices with special supervisory indication at the control panel. Monitored circuit may be wired as an NFPA Style B(Class B)or Style D (Class A) Initiating Device Circuit. A 47K ohm End-of-Line Resistor (provided) terminates the Style B circuit. No resistor is required for supervision of the Style D circuit. DN-6999:C•10/06/2010—Page 1 of 4 NMM-100P(A) Mini Monitor Module Dimensions: 1.3" (3.302 cm) high x 2.75" (6.985 cm)wide x • Built-in type identification automatically identifies this device 0.65"(1.651 cm)deep. as a monitor module to the panel. Wire length:6"(15.24 cm)minimum. • Powered directly by two-wire SLC loop.No additional power required. NZM-100(A) Interface Module • High noise(EMF/RFI)immunity. • Supports compatible two-wire smoke detectors. • Tinned,stripped leads for ease of wiring. • Supervises IDC wiring and connection of external power • Direct Decade entry of address: 01 — 99 on FireWarden- source. 100-2,01 —50 on FireWarden-50. • High noise(EMF/RFI)immunity. • SEMS screws with clamping plates for ease of wiring. 23 1415 0 1 ADDRESS o 1 • Direct Decade entry of address:, 01 —99 on FireWarden- s13 2 100-2,01 —50 on FireWarden-50. , 4O � 12 3 42. 2 3 LED flashes duringnormal operation. LOOP P 11 ,- 4 ,• 4 • LED latches steady d t toindicate t alarm on command from Y ca e 10 5 5 control panel. g $ 6 g 8 7 6 TENSONES The NZM-100(A)Interface Module is intended for use in intelli- n n gent, addressable systems, where the individual address of each module is selected usingbuilt-in rotaryswitches. This module allows intelligent panels to interface and monitor two- 3 i— wire conventional smoke detectors.It transmits the status(nor- 0 LuY mal,open,or alarm)of one full zone of conventional detectors W - U back to the control panel. All two-wire detectors being moni- ro tored must be UL compatible with the module. NZM-100(A) APPLICATIONS Use the NZM-100(A) to monitor a zone of two-wire smoke detectors. The monitored circuit may be wired as an NFPA - Style B(Class B)or Style D(Class A) Initiating Device Circuit. The NMM-100P(A) Mini Monitor Module can be installed in a A 3.9 K ohm End-of-Line Resistor (provided) terminates the single-gang junction directly behind the monitored unit. Its end of the Style B or D (class B or A) circuit (maximum IDC small size and light weight allow it to be installed without rigid loop resistance is 25 ohms). Install ELR across terminals 8 mounting.The NMM-100P(A) is intended for use in intelligent, and 9 for Style D application. two-wire systems where the individual address of each module is selected using rotary switches. It provides a two-wire initiat- NZM-100(A)OPERATION ing device circuit for normally-open-contact fire alarm and Each NZM-100(A) uses one of the available module security devices. NMM-100P(A) addresses on an SLC loop. It responds to regular polls from APPLICATIONS the control panel and reports its type and the status(open/nor- NMM-100P(A) mal/short)of its Initiating Device Circuit(IDC).A flashing LED Use to monitor a single device or a zone of four-wire smoke indicates that the module is in communication with the control detectors,manual fire alarm pull stations,waterflow devices,or panel. The LED latches steady on alarm (subject to current other normally-open dry-contact devices. May also be used to limitations on the loop). monitor normally-open supervisory devices with special super- visory indication at the control panel. Monitored circuit/device NZM-100(A)SPECIFICATIONS is wired as an NFPA Style B(Class B)Initiating Device Circuit. Nominal operating voltage: 15 to 32 VDC. A 47K ohm End-of-Line Resistor(provided)terminates the cir- Maximum current draw:5.1 mA(LED on). cuit. NMM-100P(A)OPERATION Maximum IDC wiring resistance:25 ohms. Average operating current: 300 pA, 1 communication and 1 Each NMM-100P(A) uses one of the available module LED flash every 5 seconds,3.9k eol. addresses on an SLC loop. It responds to regular polls from the control panel and reports its type and the status(open/nor- EOL resistance:3.9K ohms. mal/short)of its Initiating Device Circuit(IDC). External supply voltage (between Terminals T3 and T4): NMM-100P(A) SPECIFICATIONS DC voltage: 24 volts power limited. Ripple voltage: 0.1 Vrms maximum.Current:90 mA per module maximum. Nominal operating voltage: 15 to 32 VDC. Temperature range:32°F to 120°F(0°C to 49°C). Average operating current: 350 pA, 1 communication every 5 seconds, 47k EOL; 600 pA Max. (Communicating, IDC Humidity range: 10%to 93%noncondensing. Shorted). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x Maximum IDC wiring resistance:40 ohms. 1.25" (3.175 cm) deep. Mounts to a 4" (10.16 cm) square x 2.125"(5.398 cm)deep box. Maximum IDC Voltage: 11 Volts. - Maximum IDC Current:400 pA. 1 EOL resistance:47K ohms. Temperature range:32°F to 120°F(0°C to 49°C). Humidity range: 10%to 93%noncondensing. Page 2 of 4—DN-6999:C•10/06/2010 NDM-100(A) Dual Monitor Module • MEA: 72-01-E Vol. 2 (NMM-100, NMM-100P, NZM-100); 227-03-E Vol.3(NDM-100) The NDM-100(A) Dual Monitor Module is intended for use in intelligent, two-wire systems. It provides two independent two Product Line Information initiating device circuits(IDCs)at two separate,consecutive addresses.It is capable of monitoring normally open contact fire NOTE:"A"suffix indicates ULC-listed model. alarm and supervisory devices.The module has a single panel NMM-100(A)• Monitor module. controlled LED. NOTE: The NDM-100(A)provides two Style B(Class B)IDC cir- NMM-100P(A):Monitor module,miniature. cults ONLY Style D(Class A)IDC circuits are NOT supported in NZM-100(A):Monitor module,two-wire detectors. any application. NDM-100(A): Monitor module, dual,two independent Class B NDM-100(A)SPECIFICATIONS circuits. Normal operating voltage range: 15 to 32 VDC. SMB500:Optional surface-mount backbox. Maximum current draw:6.4 mA(LED on). NOTE: See installation instructions and refer to the SLC Wiring Average operating current:750 pA(LED flashing). Manual,PN 52304. Maximum IDC wiring resistance: 1,500 ohms. Maximum IDC Voltage: 11 Volts. Maximum IDC Current:240 pA EOL resistance:47K ohms. Maximum SLC Wiring resistance:40 Ohms. Temperature range:32°to 120°F(0°to 49°C). Humidity range: 10%to 93%(non-condensing). Dimensions: 4.5" (11.43 cm) high x 4" (10.16 cm) wide x 2.125"(5.398 cm)deep. NDM-100(A) AUTOMATIC ADDRESSING The NDM-100(A) automatically assigns itself to two address- able points, starting with the original address. For example, if the NDM-100(A) is set to address "26", then it will automati- cally assign itself to addresses"26"and"27". NOTE: "Ones"addresses on the NDM-100(A)are 0, Z 4, 6, or 8 only. Terminals 6 and 7 use the first address,and terminals 8 and 9 use the second address. ACAUTION: Avoid duplicating addresses on the system. Installation NMM-100(A), NZM-100(A), and NDM-100(A) modules mount directly to a standard 4"(10.16 cm)square,2.125"(5.398 cm) deep, electrical box. They may also be mounted to the SMB500 surface-mount box. Mounting hardware and installa- tion instructions are provided with each module. All wiring must conform to applicable local codes,ordinances,and regu- lations. These modules are intended for power-limited wiring only. The NMM-100P(A) module is intended to be wired and mounted without rigid connections inside a standard electrical box. All wiring must conform to applicable local codes, ordi- nances,and regulations. Agency Listings and Approvals In some cases, certain modules may not be listed by certain approval agencies, or listing may be in process. Consult fac- tory for latest listing status. • UL:S635 • ULC:S635 • FM Approved • CSFM: 7300-0028:0230 (NMM-100, NMM-100P, NZM- 100);7300-0028:0237(NDM-100) DN-6999:C•10/06/2010—Page 3 of 4 Notifier®and FireWarden®are registered trademarks and FireWatchTM is a trademark of Honeywell International Inc. ®2010 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. 1SO 9001 This document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. C E R T t F 1 E We cannot cover all specific applications or anticipate all requirements. imommonnimmas @iCIliE9111 6 MCIMFACTEM+C All specifications are subject to change without notice. QUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 4 of 4—DN-6999:C•10/06/2010 DN-6994:A•Al-370 - N 100-1S0 ® NOTIFIER® Fault Isolator Module for FireWarden Series Panels by Honeywell Addressable General The NOTIFIER N100-ISO Fault Isolator Module is used with FireWarden Series panels to protect the system against wire- to-wire short circuits on the SLC loop.The N100-ISO should be O O O placed between each device on the SLC loop to isolate a short- circuit problem between the modules.It is required for true Style 7 operation so that other devices can continue to operate nor- mally in the event of a short-circuit on the SLC. CAUTION:DE-ENERGIZE Features DNR PRIOR TO SERVICING • Powered by SLC loop directly,no external power required. • Mounts in standard 4.0" (10.16 cm) square, 2.125" (5.398 0 cm)deep junction boxes. • Integral LED blinks to indicate normal condition. Illuminates • steady when short circuit condition is detected. 0 • High noise(EMF/RFI)immunity. O c N100-ISO Applications The Fault Isolator Modules should be spaced between groups of sensors in a loop to protect the rest of the loop. Use to isolate short circuit problems within a section of a loop so that other sections can continue to operate normally.The N100-ISO sup- ports a maximum of 25 devices in-between isolators, except when using relay bases. • NOTE LOADS PER RELAY BASE AND ISOLATORS/ISOLATOR 0 BASES: The maximum number of addressable devices between ., isolators(or B224B1 isolator bases)is 25 devices. t� 25 DEVICES N100-ISO CLQ N100-ISO or ISO or ISO Base detector module Base 0 B224RB relay bases draw more current than other intelligent CAUTION devices. When calculating the 25-device maximum, B224RB rep- DE-ENERGIZE UNIT PRIOR TO SERVICING resents 2.5 DEVICES;see example on page 2. NOTE: ON MAXIMUM NUMBER OF DEVICES: See the SLC Face plate for N100-ISO Manual(52304)for information on loss of addresses due to current limitations. Each module or base added reduces the capacity of address positions in an SLC. Requirements differ as applied to relay bases;see note above. Operation Specifications Automatically opens circuit when the line voltage drops below • Operating voltage: 15—28 VDC(peak). four volts. Fault Isolator Modules should be spaced between • Maximum current upon activation due to short circuit: groups of addressable devices (maximum 25, see notes on refer to the manual for the main FACP. page 1)in a loop to protect the rest of the loop.If a short occurs • Standby current:450µA maximum; N100-ISO is not isolat- between any two isolators, then both isolators immediately ing—relay closed. switch to an open circuit state and isolate the groups of sensors • Temperature range:32°F to 120°F(0°C to 49°C). between them.The remaining units on the loop continue to fully operate. • Relative humidity:10%to 93%. In Style 4 loops,the N100-ISO is generally used at each T-tap • Weight: 150 grams(5 oz.) branch, to limit the effect of short circuits on a branch to the devices on that branch. The LED indicator is on continuously • Construction during a short circuit condition. The face plate is made of off-white plastic. Module includes yel- The N100-ISO Fault Isolator Module automatically restores the low LED indicator that pulses when normal and illuminates shorted portion of the communications loop to normal. steady when a short is detected. DN-6994:A•11/10/08—Page 1 of 2 Installation Product Line Information • Mount on a standard 4" (10.16 cm) mounting junction box Ni 00-ISO:Isolator module. 7. which is at least 2.125"(5.398 cm)deep. SMB500:Optional surface-mount backbox. • Terminal screws are provided for"in and out"wiring. • Installation instructions are provided with each module. • Surface-mount box is available as an option. Engineering Specifications Fault Isolator Modules shall be provided to automatically isolate wire-to-wire short circuits on an SLC loop. The Fault Isolator Module shall limit the number of modules or detectors that may be rendered inoperative by a short circuit fault on the SLC Loop. If a wire-to-wire short occurs, the Fault Isolator Module shall automatically open-circuit(disconnect)the SLC loop.When the short circuit condition is corrected, the Fault Isolator Module shall automatically reconnect the isolated section of the SLC loop. The Fault Isolator Module shall not require any address- setting,and its operations shall be totally automatic. It shall not be necessary to replace or reset an Fault Isolator Module after its normal operation.The Fault Isolator Module shall mount in a standard 4" (10.16 cm) deep electrical box, in a surface- mounted backbox, or in the Fire Alarm Control Panel. It shall provide a single LED which shall flash to indicate that the Isola- tor is operational and shall illuminate steadily to indicate that a short circuit condition has been detected and isolated. Agency Approvals and Listings These listings and approvals apply to the modules specified in this document. In some cases, certain modules or applications may not be listed by certain approval agencies,or listing may be in progress.Consult factory for listing details. • UL Listed:S635 • CSFM:7300-0028:238 • MEA:427-91-E Vol.9 • FM Approved Example of Device Count See notes under Applications on page 1. STARTS NEXT COUNT N100-ISO N100-ISO Module Module detector with detector with module standard base relay base COUNTS AS ... 1 + 3.5 + 1 = 5.5 El (2.5 + 1) (less than 25 total) Notifier® and FireWarden® are registered trademarks of Honeywell International Inc. 02008 by Honeywell International Inc.All rights reserved.Unauthorized use of this document is strictly prohibited. ISO 9001 This document is not intended to be used for installation purposes. :i::: ::. : We try to keep our product information up-to-date and accurate. •:. CERT F 1 E D We cannot cover all specific applications or anticipate all requirements. nomoom 06EMHINI 6 MMIMtII M1I All specifications are subject to change without notice. SUALITY SYSTEMS Made in the U.S.A. For more information,contact Notifier.Phone:(203)484-7161,FAX:(203)484-7118. www.notifier.com Page 2 of 2—DN-6994:A•11/10/08