Loading...
Permit (41) CITY OF TIGARD COMMERCIAL MANUFACTURED STRUCTURE PERMIT '11111 ' COMMUNITY DEVELOPMENT T I(i A k 0 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Permit#: CMS2019-00002 Date Issued: 06/18/2019 Parcel: 2S111 ACO2700 Site address: 14650 SW 97TH AVE Jurisdiction: Tigard Project: Twality Middle School Subdivision: None Lot: None Project Description: Relocating(5)portable classroom buildings. Contractor: PACIFIC MOBILE Owner: UNION HIGH SCHOOL DISTRICT PO BOX 1404 NO. 3 JT CHEHALIS,WA 98532 00000 PHONE: 360-748-0121 PHONE: FAX: FEES Specifics: Description Date Amount Type of Use: COM MH State Admin 04/18/2019 $30.00 Class of Work: ALT Type of Const: MH BLD Permit 04/18/2019 $1,377.50 Occupancy Group: 12%State Surcharge-Building 04/18/2019 $165.30 Stories: 0 Height: 0 ft Project Valuation: $0.00 Floor Areas: First Floor Area: 0 Second Floor Area: 0 Third Floor Area: 0 Total Area: 0 Required Setbacks: Left: 0 Right: 0 Front: 0 Rear: 0 Required: Parking Spaces: 0 Fire Sprinklers: Total $1,572.80 Smoke Detectors: Party Wall: Required Items and Reports(Conditions) This permit is issued subject to the regulations contained in the Tigard Municipal Code,State of OR.Specialty Codes and all other applicable law. All work will be done in accordance with approved plans.This permit will expire if work is not started within 180 days of issuance,or if work is suspended for more the 180 days.ATTENTION:Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: 1` //PI"' •ermi ee Signature: }o Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. VIIf. Manufactured Dwelling Placement Permit Application �E® FOR OF► ►cl: t sl_ ()yI.v Cl of Tigard L. Received `Jby C Permit 13125 SW Hall Blvd.,Tigard,OR 97223 Date/By: '• j 1{ i 9 Pit Ned.-*-73' /f�/—ett)c,°,), I 1 1 2Ut9 Plan ReviewCi Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: n ) y , Inspection Line: 503.639.4175 Date Read/B I .: ee ��� C L ht I 1 C;A R t) . Ready/By: ® See Plan Submittal Internet: www.tigard-or.gov *--,1 N I .�••l` I;l Notified/Method: I q ,r Requirements JOB SITE I\FORVIATION O\1'\ER 1\FORM.1F1O\ Site Address: 14650 SW 97'Ave,Tigard OR 97224 Name: Tigard-Tualatin School District Park Name: Twality Middle School-Track Address: 6960 SW SandburgStreet Subdivision&Lot#: Directions to inspection site: City: TIgard I State: OR I ZIP: 97224 Twality Middle School Track-Behind Main Bldg. Phone: 971-727-4168 I Fax: Is property inside city limits? ® Yes ❑ No E-mail: shawn.christensen@otak.com Zoning Sanitation Signature: Signature: Jurisdiction: Jurisdiction: Date: Date: AL1\IF.1CTt REI) D\1 ELLI.AG PL_1(E\IEyT PFR\II I FEES (1) Installation/re-inspection Cost(each) No.of Sum Items (a) Placement(includes placement,electrical feeder,30'of water/sewer connection). $ 275.50 5 j $ (b) State surcharge at 12%. $ 33.06 5 $ (b) Re-inspection(includes inspection and 12%state surcharge). $ 70.00 $ Placement permit to be obtained only by homeowner,or Oregon-licensed manufactured dwelling installer. (2) Electrical (a) Service and/or feeder(new service installation or alteration/relocation of existing service). $ See Electrical Permit Application Electrical service permit to be obtained only by homeowner performing work or signing supervisor of Oregon-licensed electrical contractor performing work. (3) Plumbing (a) New water service(for services over 30 lineal feet)- $ See Plumbing Permit Application ,t (b) New sanitation/storm sewer or rain drain(for services over 30 lineal feet)• $ See Plumbing Permit Application IA `` Plumbing permit to be obtained only by homeowner performing work or Oregon-licensed plumbing contractor performing work. (4) Miscellaneous fees 11 (a) Administrative fee. $ 30.00 / $ (b) System development fees(sewer connection,storm water,parks development&traffic impact). $ See Permit&System Development Fees y: SUB-TOTAL $ SET-UP OR I\ST:UAL:ITION COYIR:ACFOR 1PPLIC:1\T Name: Pacific Mobile Structure Name: Day CPM I Shawn Christensen Address: PO Box 1404/1554 Bishop Road Address: 6960 SW Sandburg Street City: Chehalis I State: WA I ZIP: 98532 City: Tigard I State: OR I ZIP: 97224 Phone: 800.225.6539 Fax: Phone: 503-523-8103 I Fax: CCB No.: #50832 MDI No.: E-Mail: shawn.christensen@otak.com Name: Pacific Mobile Structure I hereby certify that the information above is true and correct All work to be performed shall be in accordance with all Address: PO Box 1404/1554 Bishop Road governing laws and rules. City: Chehalis State: WA ZIP: 98532 `-- / 03/05/2019 Phone: 800.225.6539 Fax: Authorized Signature Date CCB No.: #50832 MDI/LSI No.: Print Name: Shawn Christensen I:\Building\Permits\SFM-PermitApp.doc 10/01/09 II Building Permit Application Plan Submittal Requirements TIGARD Manufactured Dwelling 1. SITE PLAN -Three(3) copies,fully dimensional and drawn to scale,labeled with: A. ❑ map&tax lot# El subdivision name ❑ subdivision lot# ❑ site address ❑ zoning ❑ applicant name ❑ phone number Size requirement: 8-1/2"x 11",to a maximum 11"x 17". All details listed below shall be incorporated into the site plan: B. North arrow. C. "Drawn to scale"indicates standard architect or engineer scale. D. Footprint of structure,including accessory structures,garage,carport and decks shall reflect actual building dimensions,including retaining walls. E. Finished floor elevations,all levels. F. Garage finished floor elevation. G. Corner lot elevations. If more than 4 feet elevation differential,plan must show contour lines at 2-foot intervals. H. Location of all cuts and fills on the lot. I. Driveway corner elevations. J. Zoning setbacks (front,side and rear). K. The location of all public and private easements. L. The location,termination,and all invert elevations of all drainage piping(sanitary and storm) showing all elevations necessary to show positive gravity flow to the approved drainage device (i.e.peepholes,storm lateral, sanitary lateral). M. Residential driveways,sidewalks will be shown on site plans and will be in accordance with the City of Tigard standards. Driveway cuts shall not be permitted within 30 feet of intersecting right-of-way lines,nor within 6 feet of property lines. Weep holes/drain pipes will be installed 6 feet from adjoining property lines. Multiple driveways on individual parcels of land must have 30 feet of separation;joint-use driveways require a formal agreement. N. Show all erosion control devices proposed for site. Contact Clean Water Services (CWS) at 503-681-5113 for assistance. 0. Show location of existing facilities and new or relocated structures (utilities,well/septic systems,mailboxes, power poles,water meter,light pole,stop sign,etc.). P. Indicate property slope directions. Q. Existing and finished contours when slope in any direction exceeds 20% (additional requirements may apply-see grading policy). R. Site plan to include tree size,type and location per approved project street tree plan (if applicable),and City of Tigard Street Tree List. S. Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations, driplines,and protection measures must be drawn to scale and must include the project arborist's signature of approval. 2. BUILDING PLANS -Three (3)full sets for illustrating the manufactured dwelling foundation or basement construction(no redlines or tape-ons accepted). Size requirement: up to 24"x 36"maximum, folded into eighths (9"x 12")with the plans inside. No rolled, reversed or mirrored plans will be accepted. All details listed below shall be incorporated into the building plans: A. Scale (architectural or engineering only). B. Cross sections of the manufactured dwelling foundation or basement(every set of plans shall contain a minimum of two cross sections at mid-point of each direction). C. Exterior elevation(all views shall be shown). D. Basement wall,foundation and retaining wall sections. E. Documentation by manufacturer indicating that manufactured dwelling roof can support over-framing of garage roof. F. Driveway construction. 1:\Building\Permits\SFM-PermitApp.doc 10/01/09 Branden Taggart From: Branden Taggart Sent: Tuesday, March 19, 2019 12:52 PM To: Shawn Christensen Cc: #Building Permit Technicians Subject: RE: Twality Middle School I Portables Project Permitting: CMS2019-00002 Great,thank you. This one permit will encompass all five portables then. Thanks, Branden Taggart r City of Tigard Senior PermitTechniciar r Community Development TICS, 13125 SW Fall Blvd Tigard,OR 97223 (503)718-2449 brandent tigard-or.gav From: Shawn Christensen <Shawn.Christensen@otak.com> Sent:Tuesday, March 19, 2019 12:44 PM To: Branden Taggart<brandent@tigard-or.gov> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>;Tom Hochstatter<TomH@tigard-or.gov> Subject: RE:Twality Middle School I Portables Project Permitting: CMS2019-00002 Yes, The work for the portables and the inspections will be done at the same time this summer. The entire project will be complete before school starts 9/2019. Shawn Christensen I Project Manager DAY CPM, an Otak division Direct:971.727.4168 1 Text: 971.727.4168 From: Branden Taggart<brandent@tigard-or.gov> Sent:Tuesday, March 19, 2019 12:40 PM To:Shawn Christensen <Shawn.Christensen@otak.com> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>;Tom Hochstatter<TomH@tigard-or.gov> Subject: RE:Twality Middle School I Portables Project Permitting: CMS2019-00002 Hi Shawn, Thanks for your call earlier. Tom and I reviewed the plans together, and we understand that page A1.0 combines the old and new portables now. It was not clear to us initially because page A1.0 made reference to restroom portables like it was a part of the new scope of work, and also the new location of the portables on this page was not clouded like on other pages. Now that you have cleared things up, nothing more needs to be done. 1 I will still need to know if the work and inspections for the portables will take place at the same time or not. Please see my previous email below. This will tell me how many permits to create. Thanks, Branden Taggart `'� i City of Tigard ei • Senior Permit Technician Community Development TIG; IM 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov From: Branden Taggart Sent:Tuesday, March 19, 2019 9:43 AM To: Shawn Christensen <Shawn.Christensen@otak.com> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov>;Tom Hochstatter<TomHCa@tigard-or.gov> Subject: RE:Twality Middle School I Portables Project Permitting: CMS2019-00002 Importance: High Hello Shawn, I spoke with Tom about the configuration of the portable classrooms as well as the number of portables shown in the plans. On page C2.1,the portable configuration shows (4) north-south portables with (1) portable going east- A1.0 there area (14) portables mostly placed side-by-side with adjacent restroom portables. I on page west. However, am assuming that the configuration as shown on A1.0 may be the older plan set? Furthermore, the electrical pages that follow on page E2 show the A1.0 configuration as well. Tom concurred that the plan sets will need to be revised and pages replaced for all (3) sets. Please let me know if you have additional questions. Thanks, Branden Taggart NIq City of Tigard ,, Senior Permit Technician Community Development 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent©ti rd-Or.gov From: Branden Taggart Sent: Monday, March 18, 2019 5:36 PM To: Shawn Christensen <Shawn.Christensen@otak.com> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: RE:Twality Middle School I Portables Project Permitting Hi Shawn, Looking through your submittal for the portables,you submitted (5) separate Manufactured Dwelling placement permit applications. I would just like to confirm that the inspections will not be taking place at the same time. We can create (1) permit if the work and inspections were to take place at the same time. Regarding the plan pages that make reference to (6) relocated portable buildings instead of(5), I will need to run this by Tom Hochstatter tomorrow to see how he would like to proceed. We essentially need to know what is relevant and what is not. I will get back to you tomorrow after my conversation with Tom. Thanks, Branden Taggart �,,,„,a City of Tigard i a,f• Senior Permit Technician � illa��a�m-� !,' Community Development 13125 SW Hall Blvd Tigard,OR 97223. (503)718-2449 brandenf@tigard-or.goy From: Branden Taggart Sent:Wednesday, March 6, 2019 7:47 AM To: Shawn Christensen <Shawn.Christensen@otak.com> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: RE:Twality Middle School I Portables Project Permitting Hi Shawn, We issued (9) separate permits for the previous Twality modular classroom permits but with (3)site copies and (3) sets of plans for all (9) buildings. I spoke with Mark VanDomelen this morning, and he mentioned that if you are moving the modular buildings and scheduling inspections at the same time,we can issue (1) building permit for all (5) buildings with (3) site copies and (3) sets of plans. If you need further clarification, please give me a call, and we can discuss this. Thanks, Branden Taggart ISq City of Tigard s Senior Permit Technician Community Development TIGARD 13125 SW Hall Blvd Tigard,OR 97223 (503)718-2449 brandent@tigard-or.gov From: Shawn Christensen <Shawn.Christensen@otak.com> Sent:Tuesday, March 5, 2019 4:21 PM To: Branden Taggart<brandent@tigard-or.gov> Cc:#Building Permit Technicians<TigardBuildingPermits@tigard-or.gov> Subject: Re: Twality Middle School I Portables Project Permitting So for 5 buildings you want 15 sets of plans? 3 Shawn Christensen I Project Manager DAY CPM,an Otak division Direct: 971.727.4168 I Cell: 971.727.4168 On Mar 5, 2019, at 4:19 PM, Branden Taggart<brandent@tigard-or.gov>wrote: Hi Shawn, I have attached the permit application above for manufactured dwelling permits. The second page lists the required plans: • (3) site plans • (3) sets of plans Thanks, <image001.jpg> From:Shawn Christensen <Shawn.Christensen@otak.com> Sent:Tuesday, March 5, 2019 2:35 PM To: Branden Taggart<brandent@tigard-or.gov>; #Building Permit Technicians <TigardBuildingPermits@tigard-or.gov> Subject:Twality Middle School I Portables Project Permitting Hello Branden, I?m filling out permit applications for moving 5 existing Tigard-Tualatin portable classrooms onto the Twality track this summer and am trying to put together the print order. BUP ? (1) Building permit application for all (5) buildings • (3) complete sets of drawings SFM ? (1) application for each of the (5) buildings for a total of(5) applications. • How many sets of drawings? SIT? (1) Sitework permit application • (3) complete sets of drawings PLMU - (1) Site plumbing permit application • (2) complete civil sets EIC? (1) electrical permit application • (2) complete electrical sets Thanks- <image003.png> Shawn Christensen, PMP I Project Manager STRENGTHS:Responsibility I Relator I Restorative I Empathy I Adapatability 12745 SW Beaverdam Road,Suite 120 I Beaverton, OR 97005 Direct: 971.727.4168 I Text: 971.727.4168 vvvyw.gtak.com I www.daycpm.com 4 . . ` . .______-__________„ „_ DISCLAIMER: E-mails sent or received by City of Tigard employees are subject to public record laws. If requested, e-mail may be disclosed to another party unless exempt from disclosure under Oregon Public Records Law. E-mails are retained by the City of Tigard in compliance with the Oregon Administrative Rules"City General Records Retention Schedule." «SFK0_PernoitApp_06181S.pdf> Engineering Review Slope at building pad: r4-4-1 ❑ PFI Permit#: ❑ Conditions "Met"prior to issuance of building permit ❑ Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: 0 Yes -ET No Assess Water Quantity Fee in-lieu: ❑ Yes No LIDA Facility on lot: '1 Yes 0 No ❑ NOT Approved by Engineering: Date Notes: Approved by Engineering: Date: 4A0 1 Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved 0 Not Approved Revision 2: 0 Approved 0 Not Approved Revision 3: ❑ Approved 0 Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: J 1;1--S—DC Fees Entered: Wash Co Trans Dev Tax: 0 Yes IEV /A Tigard Trans SDC: 0 Yes en-N/A Pants SDC: 0 Yes OK to Issue Permit �' y� Approved by Permit Coordinator: ���,�a Date: °.°11/13/fir d/° I-J I:\Building\Forms\BldgPernutRvw COM_WithLandUse_070915.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 14650 SW 97TH AVE, TIGARD, OR, 97224 Record Type: Record ID: Commercial - Manufactured Structure CMS2019-00002 Inspection Type: Inspector: 899 MFG-Structure final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor