Loading...
Report (4) 1 5-16 rzi Roseburg MST2019-00139 114209 SW 169TH AVE RECEIVEQpg MST2019-00138 14203 SW 169TH AVE�1"r``�t PIT%AIIPfb t ,r'rl>:'rr' MST2019-00140 114217 SW 169TH AVETy( 7 1 of 1 CS Beam 2016.,.0.13 FFh ' FEB 0 7 2019 krBearnEngme4.13.15.1 MST2019-00141 114221 SW 169TH AVE Materials Database 1547 MST2019-00142 14225 SW 169TH AVE CITY Of TICARD Member Data BUILDING DIVISION Description: Member Type: Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam1 Other Loads Type Other Dead (Description) Side Begin End Start End Start End Category Point(PLF) Top 0' 0.00" 0 80 Live Point(PLF) Top 0' 0.00" 50 34 Roof "I rt It` / / / / / 2001050 1430 0 2680 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 2' 0.000" Wall DFL Plate(625psi) 5.500" 3.500" 643# - 2 12' 5.000" Wall DFL Plate(625psi) 5.500" 3.500" 1038# - 3 26' 8.000" Wall DFL Plate(625psi) 2.750" 1.750" 418# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Roof Dead 1 367#(276p1f) 82#(62p1f) 276#(207p1f) 2 832#(624p1f) -17#(-12p1f) 205#(154p10 3 323#(243p10 2#(2p10 95#(71 plf) Design spans 2' 0.000"(left cant) 10' 5.000" 14' 1.125" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1260.'# 2820.'# 44% 20.17' Odd Spans D+L Negative Moment 1318.'# 2820.'# 46% 12.42' Adjacent 2 D+L Shear 582.# 1220.# 47% 12.42' Adjacent 2 D+L Cant.Shear,Lt 290.# 1220.# 23% 1.99' Total Load D+L End Reaction 418.# 1048.# 39% 26.67' Odd Spans D+L Int.Reaction 1038.# 2000.# 51% 12.42' Adjacent 2 D+L TL Deflection 0.2159" 0.7047" L/783 20.17' Odd Spans D+L LL Deflection 0.1684" 0.3523" L/999+ 20.17' Odd Spans L TL Defl.,Lt. 0.0458" 2L/999+ 0' Odd Spans D+L LL Defl.,Lt. -0.0327" 2L/999+ 0' Even Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% Left cantilever allowable shear is for joist only SIMPSON All product names are trademarks at their respective owners KAMI L HENDERSON EWP MANAGER Strongqie Copyright(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturer's specifications. 503-858-9663 J3 MAIN 3-15-16 t.,4Roseburg 7:10am e i r4 r,l I'i,xlucts Company loft CS Beam 2016.1.0.13 kmBeamEngine 4.13.15.1 Materials Database 1547 Member Data Description: Member Type:Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued& Nailed Filename: Beam1 / / / 14 9 0 10 3 0 0 0 25 0 0 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 2.750" 1.750" 425# -- 2 14' 9.000" Wall DFL Plate(625psi) 3.500" 3.500" 1097# -- 3 25' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 287# -36# Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 332#(249p1f) 94#(70p1f) 2 844#(633p1f) 253#(190p10 3 240#(180plf) 47#(35p1f) Design spans 14' 7.125" 10' 0.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1302.'# 2820.'# 46% 5.99' Odd Spans D+L Negative Moment 1449.'# 2820.'# 51% 14.75' Total Load D+L Shear 605.# 1220.# 49% 14.74' Total Load D+L End Reaction 425.# 1048.# 40% 0' Odd Spans D+L Int.Reaction 1097.# 1775.# 61% 14.75' Total Load D+L TL Deflection 0.2330" 0.7297" L/751 6.72' Odd Spans D+L LL Deflection 0.1866" 0.3648" L/938 6.72' Odd Spans L Control: Max Int.React. DOLs: Live=100% Snow=115% Roof=125% Wind=160% SIMPSON All product names are trademarks of their respective owners KAMI L HENDERSON EWP MANAGER Copydght(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installafion according to the manufacturers specifications. 503-858-9663