Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Report (53)
mac, ;\G - O0 V5 \(3) / _- Submittal auta-v)- \.<32.9_,,,,; EI OFFICE COPY JUN - 3 2019 Prepared For: Date:April 24, 2019 CITY OF t I( A L) American Heating Inc. (AHI) BUILDING DIVISION Ken McKinley Prepared By: Job Name: Trane Oregon Providence Scholls Ferry Steve Welch Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 2 Packaged Gas/Electric Rooftop Units The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Prepared By: between submittal generation and equipment release,the product Steve Welch performance and submittal data will need to be verified. It is the TraneOregon customer's responsibility to obtain such verification. 7257 SW Kable Lane#300 Portland, OR 97224 USA 503-431-2562 direct 503-620-8031 main 971-271-4356 mobile 503-639-1454 fax Steve.Welch( Trane.com J:IJOBS1124172397141Submittal 2019-04-24 RTU-2&5 Prov Scholls.doc Table Of Contents Product Summary 1 Packaged Gas/Electric Rooftop Units (Items Al, A2) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 6 Unit Dimensions 10 Weight,Clearance&Rigging Diagram 13 Accessory 16 I April 24,2019 Tag Data- Packa ed Gas/Electric Rooftop Units (Qty: 2) Item Tag(s) Qty Description Model Number Al RTU-2 1 15 Ton Multi Zone VAV Terminal Unit Duty YSD180G4RLA--KHB000060004 A2 RTU-5 1 15 Ton Single Zone 2 Speed no VAV Duty YSD180G4RLA--KBB000060007 Product Data- Packaged Gas/Electric Rooftop Units All Units Standard efficiency Packaged Air Cooled DX Downflow 460Volt/60Hz/3phase Reliatel Condenser Fan On/Off Head Pressure Controls, Anti-Short Cycle, Temp Controls Gas Heat—Low—2 Stage for 60Hz Fan Motor operation only(warmup) Low Leak Economizer, Dry Bulb w/ Barometric Relief BACnet communications interface MS/TP Power exhaust(Fld)—Standard Low CFM/ESP On/Off 2" Pleated Filters Mery 8 Clogged filter switch, Fan failure switch and Discharge air sensing tube Misc. Accessories/Kits/Sensors (Fld) Adaptor Curb (Fld)to existing BYC170G 1st Year Whole Unit Parts Only Manufacturer Limited Warranty(less Refrigerant) Extended 2nd thru 5th Year Compressor Parts Only Manufacturer Limited Warranty Extended 2nd thru 5th Year Combustion Gas Heat Exchanger Parts Only Manufacturer Limited Warranty Item: Al Qty: 1 Tag(s): RTU-2 VAV oversized motor w/shaft ground ring Supply Air Temperature & Pressure Control Logic& Sensors for Multi-Zone VAV Terminal Units Adaptor Curb (Fld)to existing BYC170G400CC (no heat?) s/n D43143917D type 263-0749-01C Item: A2 Qty: 1 Tag(s): RTU-5 Two speed standard w/shaft ground ring Single Zone Temperature Control Logic Adaptor Curb (Fld)to existing BYC170G4LOCD s/n E07142768D FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 3 of 21 Others • Providence Scholls Ferry April 24,2019 Performance Data - Packaged Gas/Electric Rooftop Units Tags RTU-2 RTU-5 Design Airflow(cfm) 6000 6000 Design ESP (in H2O) 1.500 1.500 Component SP Add (in H2O) 0.370 0.370 Total Static Pressure (in H2O) 1.870 1.870 Indoor Mtr. Operating Power(bhp) 4.94 4.94 Indoor RPM (rpm) 863 863 IEER @ AHRI Conditions (MBh/kW) 13.2 13.2 EER @ AHRI Conditions (MBh/kW) 11.0 11.0 Cooling Entering Dry Bulb (F) 80.00 80.00 Cooling Entering Wet Bulb (F) 64.00 64.00 Ent Air Rel Humidity(%) 41.56 41.56 Ambient Temp (F) 95.00 95.00 Cooling Leaving Unit DB (F) 58.78 58.78 Cooling Leaving Unit WB (F) 55.21 55.21 Gross Total Capacity (MBh) 173.46 173.46 Gross Sensible Capacity(MBh) 155.89 155.89 Gross Latent Capacity(MBh) 17.57 17.57 Evap Coil Leav Air Temp (DB) (F) 55.94 55.94 Evap Coil Leav Air Temp (WB) (F) 54.05 54.05 Dew Point Temp (F) 52.71 52.71 Net Total Capacity(MBh) 157.89 157.89 Net Sensible Capacity(MBh) 140.33 140.33 Net Sensible Heat Ratio (Number) 0.89 0.89 Fan Motor Heat(MBh) 15.56 15.56 Heating EAT (F) 60.00 60.00 Heating LAT (F) 90.72 90.72 Heating Temp Rise (F) 30.72 30.72 Output Htg Capacity(MBh) 200.00 200.00 Output Htg Capacity w/Fan (MBh) 215.56 215.56 Evaporator Face Area (sq ft) 23.00 23.00 Evaporator Face Velocity(ft/min) 261 261 Evaporator Fin Spacing (Per Foot) 192 192 Evaporator Rows ( ) 2 2 Refrig charge (HFC-410A) - ckt 1 (Ib) 9.0 9.0 Refrig charge (HFC-410A)-ckt 2 (Ib) 5.0 5.0 Indoor Fan Type FC FC Centrifugal Centrifugal Indoor Fan Drive Type Belt Belt Outdoor Fan Type Propeller Propeller Outdoor Fan Drive Type Direct Direct Outdoor Fan Quantity( ) 2 2 Exhaust Fan Type FC FC Centrifugal Centrifugal Exhaust Drive Type Direct Direct Heating Type Gas Gas Heating Stages 2 2 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 4 of 21 Others Providence Scholls Ferry April 24,2019 Tags RTU-2 RTU-5 Supply Fan Motor Power(kW) 3.90 3.68 Exhaust fan power(kW) 0.56 0.56 Outdoor Motor Power(kW) 0.89 0.89 Compressor Power(kW) 13.47 13.47 System Power(kW) 18.05 18.05 Compressor 1 RLA(A) 15.97 15.97 Compressor 2 RLA(A) 7.74 7.74 Condenser Fan FLA(A) 1.35 1.35 Evaporator Fan FLA (A) 4.80 4.80 MCA (A) 39.00 36.00 MOP (A) 50.00 50.00 Ducted Discharge- 63 Hz (dB) 91 91 Ducted Discharge- 125 Hz (dB) 87 87 Ducted Discharge - 250 Hz (dB) 81 81 Ducted Discharge - 500 Hz (dB) 84 84 Ducted Discharge- 1k Hz (dB) 78 78 Ducted Discharge-2k Hz (dB) 75 75 Ducted Discharge -4k Hz (dB) 74 74 Ducted Discharge - 8k Hz (dB) 69 69 Ducted Inlet- 63 Hz (dB) 94 94 Ducted Inlet- 125Hz (dB) 87 87 Ducted Inlet-250 Hz (dB) 79 79 Ducted Inlet-500 Hz (dB) 76 76 Ducted Inlet- 1k Hz(dB) 70 70 Ducted Inlet-2k Hz (dB) 66 66 Ducted Inlet-4k Hz (dB) 65 65 Ducted Inlet-8k Hz(dB) 59 59 Outdoor Noise - 63 Hz (dB) 92 92 Outdoor Noise - 125 Hz (dB) 97 97 Outdoor Noise- 250 Hz (dB) 94 94 Outdoor Noise- 500 Hz (dB) 92 92 Outdoor Noise - 1k Hz (dB) 89 89 Outdoor Noise - 2k Hz (dB) 83 83 Outdoor Noise-4k Hz (dB) 79 79 Outdoor Noise- 8k Hz (dB) 75 75 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 5 of 21 Others • Providence Scholls Ferry April 24,2019 Mechanical Specifications - Packaged Gas/Electric Rooftop Units Item: Al,A2 City:2 Tag(s): RTU-2, RTU-5 - General - Downflow The units shall be dedicated downflow airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. Packaged Rooftop units cooling, heating capacities, and efficiencies are AHRI certified within scope of AHRI Standard 340/360 (I-P) and ANSIZ21.47 and 10 CFR Part 431 pertaining to Commercial Warm Air Furnaces (gas heating units). Casing - Downflow Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal,service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2 inch, 1 pound density foil-faced, fire-resistant, permanent, odorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2 inch, 1 pound density foil-faced, closed-cell material. The downflow unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1-1/8 inch high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. Unit Top The top cover shall be one piece, or where seams exist, double hemmed and gasket sealed to prevent water leakage. Filters Two inch standard filters shall be factory supplied on all units Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have crankcase heaters, phase monitors and low and high pressure control as standard. Dual compressors are on all standard efficiency models. Crankcase Heaters These band heaters provide improved compressor reliability by warming the oil to prevent migration during off-cycles or low ambient conditions. Refrigerant Circuits Each refrigerant circuit shall have service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. Evaporator and Condenser Coils Evaporator Coils (only on T/YS*150, 180, 210, 240, 300G models)- Microchannel evaporator coils will be burst tested by the manufacturer. Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Coils shall be leak tested to ensure the pressure integrity. The evaporator coil shall be leak tested to 225 psig and pressure tested to 450 psig. Condenser Coils(available on T/Y**150, 180,210, 240, 300G models)-Microchannel condenser coils shall be standard on all units. Coils shall be leak tested to ensure the pressure integrity. The condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. Gas Heating Section The heating section shall have a drum and tube heat exchanger design using corrosion resistant steel components. A forced combustion blower shall supply premixed fuel to a single burner ignited by a pilotless hot surface ignition system. In order to provide reliable operation, a negative pressure gas valve shall be used on standard furnaces and a pressure FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 6 of 21 Others Providence Scholls Ferry April 24,2019 switch on furnaces with modulating heat that requires blower operation to initiate gas flow. On an initial call for heat, the combustion blower shall purge the heat exchanger 45 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas shall also comply with California requirements for low NOx emissions. Condenser Coil The microchannel type condenser coil is standard for the standard efficiency models. Due to flat streamlined tubes with small ports, and metallurgical tube-tofin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume,which leads to better compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight.All-aluminum construction improves re-cyclability. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s)shall be permanently lubricated and shall have built-in thermal overload protection. Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves. All motors shall be thermally protected. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). VAV Operation for Multi-Zone Duty with VAV Terminal Units The VFD shall receive a 0-10 Vdc signal from the unit controls based upon supply static pressure and shall cause the drive to accelerate or decelerate as required to maintain the supply static pressure setpoint. When subjected to high ambient return conditions the VFD shall reduce its output frequency to maintain operation. Multi-Speed for Single Zone Duty without VAV Terminal Units Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of Oregon Energy Code. This system incorporates a multi-speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. Variable Frequency Drive Variable Frequency Drives are factory installed and tested to provide supply fan motor speed Modulation. VFDs on the supply fan, as compared to inlet guide vanes or discharge dampers, are quieter, more efficient, and are eligible for utility rebates. All VFDs are designed to allow bypass if required. Bypass control will simply provide full nominal airflow in the event of drive failure. Bypass mode is indicated in the unit wiring manual. Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. ReliaTel controls shall be provided for all 24 volt control functions. The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort. A centralized control shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. High Pressure Cutout This option is offered for units that do not have High Pressure cutout as standard. Low Leak Economizer This accessory meets low leak requirements for ASHRAE90.1, IECC, and Oregon Energy Code; Allows 100 percent outdoor air supply from 0-100 percent modulating dampers; Comes standard with Barometric Relief; can be paired with Powered exhaust for additional building evacuation; Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system. This standard option provides extra protection to the compressors against high discharge temperatures in case of loss FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 7 of 21 Others Providence Scholis Ferry April 24,2019 of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high—Pressure control.When the discharge temperature rises above the protection limit, the bi-metal disc in the thermostat switches to the off position, opening the 24 VAC circuit. When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. When the thermostat opens the fourth time, the ReliaTel control must be manually reset to resume operation on that stage. Two-Inch Pleated Filters (MERV 8 & 13) Two inch pleated media filters shall be available on all models. BACnet Communications The BACnet communications interface allows the unit to communicate directly with a generic open protocol BACnet MS/TP Network Building Automation System Controls. Shaft Gounding Ring (FIYSHGR001,002A) 12.5-25 Ton Shaft grounding rings shall be factory installed on all VFD driven motors to provide a conductive discharge path away from the motor bearings to ground. Bearing Protection Ring shall be maintenance free circumferential ring of conductive micro fibers that discharges voltages to ground. Differential Pressure Switches These options allow for individual fan failure and dirty filter indication. The fan failure switch will disable all unit functions and "flash"the Service LED on the zone sensor. The dirty filter switch will light the Service LED on the zone sensor and will allow continued unit operation. Clogged Filter/Fan Failure Switch A dedicated differential pressure switch is available to achieve active fan failure indication and/or clogged filter indication. These indications will be registered with either a zone sensor with status indication lights or an Integrated Comfort System. Accessory- Powered Exhaust The powered exhaust shall provide exhaust of return air, when using an economizer, to maintain better building pressurization. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 8 of 21 Others Providence Scholls Ferry April 24,2019 Control Specification Sequence of Operation (Multiple-zone VAV System with Reheat) Occupied Heat/Cool: Each VAV terminal shall use pressure-independent control, with airflow measurement, to vary primary airflow and/or modulate (or stage) heat to maintain zone temperature at its occupied setpoint. The RTU shall modulate the supply fan to maintain duct static pressure at setpoint and modulate (or cycle)compressors, modulate (or stage) heat, and/or enable airside economizing to maintain discharge air temperature at setpoint. The OA damper shall modulate, in proportion to changing supply fan speed, to bring in the required amount of ventilation. Morning Warm-Up/Pre-Cool: Each VAV terminal unit shall vary primary airflow and/or modulate(or stage)heat to raise/lower zone temperature to its occupied setpoint. The RTU shall modulate the supply fan to maintain duct static pressure at setpoint and modulate(or cycle)compressors or modulate(or stage)heat to maintain discharge air temperature at setpoint. The OA damper shall remain closed, unless economizing. Fan-Pressure Optimization: The System Controller shall monitor all VAV damper positions and reset the RTU's duct static pressure setpoint based on the position of the furthest-open damper. Discharge Air Temperature Reset: The System Controller shall reset the RTU's discharge air temperature setpoint based on the current outdoor air temperature or zone cooling/heating demand. Sequence of Operation System Operating Modes: The Existing System Controller shall send the equipment controllers Occupied/Unoccupied, Morning Warm-up/Pre-cool, and Heat/Cool modes. If communication is lost, the equipment controllers shall operate using default modes and setpoints. Night Setback: During unoccupied mode, the system shall shut off. If the zone temperature drifts to the unoccupied heating or cooling setpoint, the system shall start up to heat or cool the zone, while the OA damper remains closed (unless economizing). Optimal Start: The System Controller shall automatically determine the optimal start time, such that each zone reaches its occupied setpoint just in time for scheduled occupancy. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 9 of 21 Others • Providence Scholls Ferry April 24,2019 Unit Dimensions- Packaged Gas/Electric Rooftop Units Item: Al,A2 t:fly: 2 Tag(s): RTU-2,RTU-5 NOTES: 2.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS.(SELECTED OPTION:SEE ACCESSORY SHEET) 3.VERIFY WEIGHT,CONNECTIONS,AND ALL DIMENSIONS WITH h # INSTALLER DOCUMENTS BEFORE INSTALLATION 56 1/8" Callow ,%1-:..oil .[ illow. DOWNFLOW CONDENSATE 8 1/8" DRAIN CONN 1 NPT 0 s � 26 3/4" 0 1110 505/8. 0` GAS CONNECTION(SEE NOTE 1) 1 O• 64 11/16" 11 1/16"/- DIA.HOLE (UNIT(UNIT CONTROL WIRE) 81 5/8" A 3„\ 22 1/16" 2"DIA.HOLE(UNIT POWER WIRE) 121 11/16" 531/16" PACKAGED GAS/ELECTRIC-DOWNFLOW 84 3/4" ISOMETRIC DRAWING 3 41/4" 1 -1915/16".---. 283/4"-- --..-26 7/16"-.=- 4 1/4" dripti 76 5/16" 68 11116" SUPPLY RETURN 0"� kelp,* rvo L- --J PACKAGED GAS/ELECTRIC-DOWNFLOW PLAN VIEW DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 10 of 21 Others Providence Scholls Ferry April 24,2019 Unit Dimensions - Packaged Gas/Electric Rooftop Units . item: Al Qty: I Tag(s): RTU-2 ELECTRICAL/ GENERAL DATA GENERAL PERFORMANCE Standard Motor (1)(3) Model(Ton): YSD180G(15.0) Minimum CircuitAmpacity: 36.0 Unit Operating Voltage Range: 414-506 Maximum Fuse Size: 50.0 Unit Primary Voltage: 460 Maximum(HACR)Circuit Breaker: 50.0 Unit Secondary Voltage: - UnitHertz: 60 Oversized Motor (1)(4) Field Installed Oversized Motor 11)14) Unit Phase: 3 MCA: 39.0 MCA: N/A MFS: 50.0 MFS: N/A EER:15) 11.0 MCB(HACR): 50.0 MCB(HACR): N/A GAS HEATING COMPRESSOR Heating Models: Low Circuit(s) Heating and 1 Stage Input(Btu/h) 250000/175000 Number: 2 Heating and 1 Stage Output(Btu/h): 200000/140000 Horsepower: 9.2/4.5 Min./Max.Gas Input- Phase: 3 Pressure Natural or LP: 2.5/14.0 Rated Load Amps: 14.7/7.7 Gas Connection Pipe Size: 1/2" Locked Rotor Amps: 142.0/52.0 INDOOR MOTOR Oversized Motor (4) Field Installed Oversized Motor (4) Number: (3) 1 Number. 1 Number: N/A Horsepower: 3.00 Horsepower: 5.00 Hp: N/A Motor Speed(RPM): 1,740 Motor Speed(RPM): 3,450 Motor Speed(RPM): N/A Phase: 3 Phase: 3 Phase: N/A Full Load Amps: 4.8 Full Load Amps: 7.6 FLA: N/A Locked Rotor Amps: 40.5 Locked Rotor Amps: 54.9 LRA: N/A OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Number: 2 Horsepower: 0.75 (Gas-Fired Heating only) Horsepower: 0.50 Motor Speed(RPM): 1,040 MotPhase: 1 Horsepower: 0.1 Phase:sr speed(RPM): 1,100 Full Load Amps: 3.3 Motor Speed(RPM): 3,500/2,800 Fullll Load 3 3 Locked Rotor Amps: 8.4 Phase: 1 ad Amps: 1.35 Full Load Amps: 0.8 Locked Rotor Amps: 4.82 Locked Rotor Amps: 2.00 FILTER REFRIGERANT (2) Circuit#1/2 Type: Throwaway Type: R410 Furnished: Yes Factory Charge Number: 4/4 Circuit#1/2: 9.0 lb/5.0 lb Recommended Size: 20"x20"x2"/20"x25"x2" NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value includes oversized motor. 4.Value does not include Power Exhaust Accessory. 5.EER is rated atAHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 11 of 21 Others • Providence Scholls Ferry April 24,2019 Unit Dimensions- Packaged Gas/Electric Rooftop Units . Item: A2 Qty: I Tag(s): RTU-5 ELECTRICAL/ GENERAL DATA GENERAL PERFORMANCE Standard Motor (1)(3) Model(Ton): YSD180G(15.0) Minimum Circuit Ampacity: 36.0 Unit Operating Voltage Range: 414-506 Maximum Fuse Size: 50.0 Unit Primary Voltage: 460 Maximum(HACR)Circuit Breaker: 50.0 Unit Secondary Voltage: - Unit Hertz: 60 Oversized Motor (1)t41 Field Installed Oversized Motor (1)(4) Unit Phase: 3 MCA: N/A MCA: N/A MFS: N/A MFS: N/A EER:(5) 11.0 MCB(HACR): N/A MCB(HACR): N/A GAS HEATING COMPRESSOR Heating Models: Low Circuit(s) Heating and 1 Stage Input(Btu/h) 250000/175000 Number: 2 Heating and 1 Stage Output(Btu/h): 200000/140000 Horsepower: 9.2/4.5 Min./Max.Gas Input- Phase: 3 Pressure Natural or LP: 2.5/14.0 Rated Load Amps: 14.7/7.7 Gas Connection Pipe Size: 1/2" Locked Rotor Amps: 142.0/52.0 INDOOR MOTOR Oversized Motor (4) Field Installed Oversized Motor (4) Number: (3) 1 Number. N/A Number: N/A I Horsepower: 3.00 Horsepower: N/A Hp: N/A i Motor Speed(RPM): 1,740 Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase: 3 Phase: N/A Phase: N/A Full Load Amps: 4.8 Full Load Amps: N/A FLA: N/A Locked Rotor Amps: 40.5 Locked Rotor Amps: N/A LRA: N/A OUTDOOR MOTOR POWER EXHAUST COMBUSTION BLOWER (Field Installed Power Exhaust) MOTOR Number: 2 Horsepower: 0.75 (Gas-Fired Heating only) Horsepower: 0.50 Motor Speed(RPM): 1,040 Motor speed(RPM): 1,100 Phase: 1 Horsepower: 0.1 Phase: 3 Full Load Amps: 3.3 Motor Speed(RPM): 3,500/2,800 Locked Rotor Amps: 8.4 Phase: 1 Full Load Amps: 1.35 Full Load Amps: 0.8 Locked Rotor Amps: 4.82 Locked Rotor Amps: 2.00 FILTER REFRIGERANT )21 Circuit#1/2 Type: Throwaway Type: R410 Furnished: Yes Factory Charge Number: 4/4 Circuit#1/2: 9.0 lb/5.0 lb Recommended Size: 20"x20"x2"/20"x25"x2" NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value includes oversized motor. 4.Value does not include Power Exhaust Accessory. 5.EER is rated at AHRI conditions and in accordance with DOE test procedures. • FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 12 of 21 Others 4 Providence Scholls Ferry April 24,2019 Weight, Clearance &Rigging Diagram - Packaged Gas/Electric Rooftop Units Item:Al,A2 Qty:2 Tag(s): RTU-2, RUU-5 \-/ . CLEARANCE 68" (1727.2mm) . 7 CLEARANCE FROM THE (914.4mm)CLEARANCE 36" TOP OF UNIT 72" (1828.8mm) P P %v CLEARANCE 60" c o (1524mm) P CLEARANCE 48" .t2. (1219.2mm) g DOWNFLOW-PACKAGED GAS/ELECTRIC CLEARANCE UNIT OUTLINE—\2„,„, ,...........--------. .........„...., 44 ROOF OPENING 76 1/2" 81" DOWNFLOW-PACKAGED GAS/ELECTRIC ROOF OPENING CLEARANCE 1 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 13 of 21 Others • Providence Scholls Ferry April 24,2019 Weight, Clearance & Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: Al Qty: I 1a4(S) RTU--2 • Base Unit and Corner Weights only Base unit weights Corner Weights Center of Gravity �� SHIPPING NET OA BO OC O E F 2269.0 lb 1838 595.0 lb 497.0 lb 355.0 lb 390.0 lb 45" 34" \\Il``l`!'-g») 1.All weights are approximate. \���\��/// 2.The actual weight are listed on the unit nameplate. �� 3.Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. ie �� 4.The weight shown represents the typical unit operating weight for the configuration ��((��/�,,`�\\1 selected.Estimated at+/-10 %of the nameplate weight.. WI`���" 5.Verify weight,connection,and all dimension with installer documents before installation. \`\ �J 6.Corner weights are given for information only. �� 7.Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. - _ _ _ ,� Installed Options Net Weight Data Accessory Weight CORNER WEIGHT Economizer,Manual and Motorized Outside Air Damper Power Exhaust 95.0 lb Roof Curb Oversized Motor Hail Guard Hinged Access Doom Power Cony.Outlet Through the Base Electrical Circuit Breaker Disconnect Smoke Detector Novar Zone Sensor 11 High/Low Static Drive Kit LP Gas Conversion Stainless Steel Heat Exchanger Stainless Steel Drain Pan VFD 63.0 lb High Efficiency Motor 1.Weights for options are approximate. 2.Weights for options that are not list refer to Installation guide. .I.\ 1 • • N04%.444. frifr 0 `I AN....406.6%,. 0 �t7 PACKAGED GAS/ELECTRIC RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 14 of 21 Others Providence Scholls Ferry April 24,2019 Weight, Clearance & Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: A2 Qty: 1 Tag(s): RTU-5 F Base Unit and Corner Weights only Base unit weights Corner Weights Center of Gravity SHIPPING NET OA BO © D© E F 2269.0 lb 1838 595.0 lb 497.0 lb 355.0 lb 390.016 45" 34" lf�/f� 1.All weights are approximate. /�/�� 2.The actual weight are listed on the unit nameplate. 3.Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. Matt 4.The weight shown represents the typical unit operating weight for the configuration ��((��/ \111 selected.Estimated at+/-10 %of the nameplate weight.. 1'111�/� 5.Verify weight,connection,and all dimension with installer documents before installation. \`\"��l 6.Corner weights are given for information only. 7.Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. / Installed Options Net Weight Data (^��' Accessory Weight CORNER WEIGHT Economizer,Manual and Motorized Outside Air Damper Power Exhaust 95.0 lb Roof Curb Oversized Motor Hail Guard Hinged Access Doors Power Cony.Outlet Through the Base Electrical Circuit Breaker Disconnect Smoke Detector Novar Zone Sensor High/Low Static Drive Kit LP Gas Conversion Stainless Steel Heat Exchanger Stainless Steel Drain Pan VFD 32.0 lb High Efficiency Motor 1.Weights for options are approximate. 2.Weights for options that are not list refer to Installation guide. ' .000000.00010 Ih. .444044..iNist 0 rimj PACKAGED GAS/ELECTRIC RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 15 of 21 Others Providence Scholls Ferry April 24,2019 Accessory- Packaged Gas/Electric Rooftop Units - Item: Ai, A/ may: 2 Tager: RTU-2, RTU-5 END PANEL ACCESS PANEL � 1 78" ECONOMIZER HOOD 19 1/2" ECONOMIZER HOOD PLAN VIEW DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 16 of 21 Others • Providence Scholls Ferry April 24,2019 Accessory- Packaged Gas/Electric Rooftop Units Item:Al, A2 Qty:2 Tag(s): RTU-2,RTU-5 0 END PLANEL 0 ECONOMIZER / HOOD 1 t/% .1 -4.40-71 DOWNFLOW ACCESSORY-POWER EXHAUST POWER EXHAUST 39" FROUNT OF POWER EXHAUST FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 17 of 21 Others DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 Attn: TRANE Tag: BYC/BTC 170 1-6 76 1/4" 60 3/4" RETURN SUPPLY AIR AIR 1 7/8" 16 3/4" —0- 1" 32 13/16" * Verify existing curb OD * Verify supply and return openings * Note any changes DIMENSIONS ARE]RD ANGLE * Call with any questions AS FOLLOWS: PROJECTION Els04Imml * Fax back if drawing is OK as is APPROVALS DATE TITLE: °"'"I A.LUTTINEN 6/28/06 TRANE CHECKED: CURB MGMT: ROOF 17560 TYLER ST NW FILE NAME: DRAWING NO.: REV: 02 UPDATED ADDRESS 6/28/06 _ CD 3665 01 INITIAL DESIGN 9/23/02 MG TELK RIVER,0 55330 3665 x-1(763)391-7790 Eco u: RFV DFSCRIPTIC)N DATF APPRGVFD (763)3917851 SCALE:1.16 SHEET:1 OF 1 DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 Attn: TRANE Tag: YCD/TCD 15,17.5, 20, 25 TONS WSC 12.5,15,20 BAYCURB027B 1167,811 71 5/16" RETURN SUPPLY AIR AIR 80 5/8" 1 � 1 1/4"TYP. I f 24 1/16" 49 5/16" 77 7/8" * Verify existing curb OD ALL STRAIGHT AND PITCHED CURBS MUST * Verify supply and return openings HAVE DROP PANS 7-7/16" FROM TOP * Note any changes OINENSIONSARE 3RDANGLE * Call with any questions AS FOLLOWS: PROJECTION I�5%)'nmml * Fax back if drawing is OK as is APPROVALS DATE TITLE: 04 UPDATED BRACES 9/21/11 MWG DRAWN: TRANE mgreenwood 10/14/201 03 UPDATE ADDRESS 6/27/06 CHECKED: • 02 CHANGED DIMENSION STYLE TO 12/8/04 AMC: • ROOF CURB INSIDE OF R&S OPENINGS FILE NAME: DRAWING NO.: REV. 17560 TYLER ST NW 01 INITIAL DESIGN 1 1/5/01 MG CDTELK RIVER,MN 55330 '(763)391-7790 ECO a:30203020 3020 04 REV. DESCRIPTION DATE APPROVED (763)3917851 SCALE:1:20 SHEET:1 OF 1 DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 RETURN SUPPLY DROP DROP 116 7/8" 1 INSULATED 7\ PAN %rni .1 .. .1 .cr, ,,//mop / , 71 5/16" 4/ RETURN SUPPLY 80 5/8" OPP' AIR AIR #' 4.4 DROP PAN BRACES I L 1 1/4"TYP. PAN BRACES 24 1/16" 1 SHEAR 49 5/16" 2 @35 15/16"X 5" 1 2" 1 @72 3/4"X 5" 77 7/8" t _.. 3" - RETURN DROP: SUPPLY DROP: ALL STRAIGHT CURBS MUST HAVE OD-76-7/8" X 22-1/16" OD-69-5/16" X 28-5/16" RECESSED BRACES 7-7/16" FROM TOP ID-74-7/8" X 20-1/16" ID-67-5/16" X 26-5/16" 77/16" SHEAR: SHEAR: INSULATED PAN 2@ 76-7/8 X 9 7/16 2@ 69-5/16" X 9-7/16" SHEAR2@ 22-1/16" X 9 7/16 2@ 28-5/16" X 9-7/16" 76" X 43 3/8" 7 7/16'1 1N 76" 35 15/16" APPROVALS DATE TITLE: DRAWN: ckaatz 10/27/2015 T A E ROOF CURB 04 UPDATED BRACES+DROP PAN 10/29/15 CKK I CHECKED: FOR PITCHED OR STRAIGHT 03 UPDATED ADDRESS 6/27/06 SPECIFIED,TOLERANCESARE: MGMT: APPLICATIONS xe D.05 02 CHANGED DIMENSION STYLE TO INSIDE OF R&S OPENINGS 12/8/04 .xx.D.DD 0JCK=:.001 9560 85TH AVE.N. FILE NAME: DRAWING NO.: REV: xxx,D.D1 US.ur3020SP 01 INITIAL DESIGN 11/5/01 MG DIMENSIONS ARE 3RD ANGLE Ll Ll MAPLE GROVE,MN 55369 3020 04 AS PROJECTION C (763)391-7790 ECO a: REV. DESCRIPTION DATE APPROVED [2S.oFOLLOWS:o, ml (763)391-7851 SCALE: 1:20 SHEET: 1 OF 1 OPTIONS: DIMENSIONED AND TOLERENCED PER ANSI Y14.5M-1982 REVISIONS MATERIAL: 14ga. GALV STEEL REV. ECO# DESCRIPTION DATE APPROVED INSULATED PANELS (WHERE REQUIRED) Attn: 1 INITIAL DRAWING 1/04/2017 HMH 1" 1-1/2LB DUCT INSULATION (R VALUE 3.85) GASKET PROVIDED WITH CURB 1 1/2"ADDED TO EXISTING CURB O.D. Tag: Approval: RETURN 77 7/8" Yzk { 49 5/16" %/' -► 241/16" - SUPPLY r r N f w - al �f j i ... vim' i.! _,•?.,�. `. y , ;',',',';';'''''z _,„;,,,,,,,,,,7,,,,,,, , t„,,:eiv///4.,4,771:::5,, ii,"4, ,,,, ,,,,,-',,,,,,,,,.,„,,-'''''. ' /74‘10F°414: ,„,:t '1 ":4°411'.V.%. " ---, ' / ;,' .cb, ',•:', ' 71 5/16" /, , 1 J 1 i VERT Al 4X r RETURN 60 3/4" 1 1/4"(TYP) 58 1/2" SUPPLY: I 2 1/4" 2 1/4"-0- -.,- 116 7/8" -0- 16 3/4" ► r 80 5/8" 1 !L ! --.- 17 3/4" f -f- 8" _ 32 13/16" ..s, \■ -F 76 1/4" 20" ' 3 ,/ 77 3/4" } 62 1/4" THIS DRAWING&THE INFORMATION CONTAINED APPROVALS DATE TITLE/FILE NAME: CURB SHOWN IS CDI STANDARD CONFIGURATION CDI RESERVES THE RIGHT TO CHANGE THEREIN!STHE CONFIDENTIAL,PROPRIETARY INFORMATION OF CRYSTAL DISTRIBUTION INC., °RA" hhorn 1/4/2017 LAYOUT WITHOUT NOTIFICATION. IF CURB IS NEEDED IN A DIFFERENT CONFIGURATION NOT BE EDORROFCRYSTALDISTRIBUTION,INC. CHECKED NELKE 1-3665-3020 CDI MUST BE NOTIFIED PRIOR TO PLACING AN ORDER. ALL RIGHTS RESERVED DIMENSIONS ARE AS FOLLOWS:1.00in[25.40mm] *VERIFY EXISTING CURB OD 'w APPROXIMATE 3" *VERIFY SUPPLY AND RETURN OPENINGS t� Contact us @ CURB WEIGHT(LBS.) ECO#: REV OPERATIONAL HEIGHT OF CDI ADAPTER IS LESS THAN OVERALL CURB HEIGHT *NOTE ANY CHANGES aR°AN°iE ip i ..--t cDu www.cdicurbs.Com 1 PROJECTION i� SHOWN. *CALL WITH ANY QUESTIONS Or 326.11 *FAX BACK IF DRAWING IS OK AS IS } 111...1.1,,,—""2:::77,17,:. 1-888-234-7001 SCALE: 1:26 SHEET 1 OF 8 S:\PRODUCTION\TURRET\STOCKCURBS\1-3665-3020\