Loading...
Report (31) Other(specify): Organization:FIRE PROTECTION SERVICES INC. 4. Alarm-Initiating Devices and Circuits(use blanks to indicate quantity of devices) MANUAL _1_Manual Stations Noncoded,Activating Transmitters Coded AUTOMATIC Coverage:Complete: Partial: (a) _2 lmoke Detectors Ion X Photo (b) Duct Detectors Ion Photo (c) Heat Detectors FT _RR FT/FF RC (d) Sprinkler Water flow Switches: Transmitters Noncoded,Activating Coded (e) Other(list): 5. Supervisory Signal-Initiating Devices and Circuits(use blanks to indicate quantity of devices) SPRINKLER SYSTEM (a) Valve Supervisory Signaling Attachments Valve Supervisory Switches,Activating Transmitters (b) Building Temperature Points (c) Site Water Temperature Points (d) Site Water Supply Level Points Electric Fire Pump: (e) Fire Pump Power (0 Fire Pump Running (g) Phase Reversal Engine-Driven Fire Pump: (h) Selector in Auto Position (i) Engine or Control Panel Trouble (j) Fire Pump Running Engine-Driven Generator: (k) Selector in Auto Position (1) Control Panel Trouble (m) Transfer Switches (n) Engine Running Other Supervisory Functions(s)(specify): N/A 6. Alarm Notification Appliances and Circuits Quantity of indicating appliance circuits connected to the system: 18 Types and quantities of alarm indicating appliances installed: (a) Bells Inch diameter (b) Speakers (c) 32 Horns (d) Chimes (e) Other: (0 4_Visual Signals Type: System Sensor 2 .I (g) Local Annunciator 7. Signaling Line Circuits Quantity and Style(see NFPA 72,Table 3-6)of signaling line circuits connected to system: Quantity: 1 Style: CLASS B 8. System Power Supplies (a) Primary(Main): Nominal Voltage: 120V Current Rating: Overcurrent Protection:Type: Current Rating: Location: (b) Secondary(Standby): 2 Storage Battery: Amp-Hour Rating 12 V 17.0AH x 2 Calculated capacity to drive system,in hours: 5MIN (24) (60) Engine-driven generator dedicated to fire alarm system: Location of fuel storage: (c) Emergency or Standby System used as backup to Primary Power Supply,instead of using a Secondary Power Supply: X Emergency System described in NFPA 70,Article 700 X Legally Required Standby System described in NFPA 70,Article 701 X Optional Standby System described in NFPA 70,Article 702,which also meets the performance requirements of Article 700 or 701 9. System Software (a) Operating System Software Revision Level(s): 15.0 (b) Application Software Revision Level(s): 15.0 (c) Revision Completed by: David M Phipps FIRE PROTECTION SERVICES INC. (name) (firm) �' `�' �' INSTALLATION SUPERVISOR (signed) (title) Frequency of routine tests and inspections,if other than in accordance with the referenced NFPA standard(s): System deviations from the referenced NFPA standard(s)are: NONE Upon completion of the system(s)satisfactory test(s)witnessed by the authority having jurisdiction: (signed)representative of the Authority Having Jurisdiction (title) (date) 3