Loading...
Permit (18) CITY OF TIGARD FIRE PROTECTION SYSTEM PERMIT IN '3 11 '' COMMUNITY DEVELOPMENT Permit#: FPS2019 00074 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 06/06/2019 Parcel: 2S113AC00103 Jurisdiction: Tigard Site address: 7244 SW DURHAM RD 100 Project: Trane Parts Subdivision: None Lot: None Project Description: Fire sprinkler permit:Adding(3)new sprinkler heads to existing system. Affidavit submitted. Contractor: AFP SYSTEMS INC Owner: PACIFIC REALITY ASSOCIATES LP 19435 SW 129TH AVE ATTN: N PIVEN TUALATIN, OR 97062 15350 SE SEQUOIA PKWY#300 PORTLAND, OR 97224 PHONE: 503-692-9284 PHONE: 503-624-6300 FAX: 503-692-1186 FEES Description Date Amount Specifics: Permit Fee-COM 06/06/2019 $64.54 12%State Surcharge-Building 06/06/2019 $7.74 Type of Use: COM Plan Review-Fire Life Safety-COM 06/06/2019 $25.82 Class of Work: ALT Type of Const: Info Process/Archiving-Sm$0.50(up to 06/06/2019 $0.50 Occupancy Grp: Height: ft 11x17) Stories: Commercial Sprinkler System: Sprinkler Required: Yes Sprinkler Type: Wet Standpipe Required: No Hazard: LT Density: .10 Design Area: 1500 K Factor: 5.6 Commercial Fire Alarm System: Fire Alarm Required: Alarm Type: Pull Station Required: Smoke Detectors Req: Battery Calcs Provided: Cut Sheets Required: Total $98.60 Valuations: Required Items and Reports(Conditions) Sprinkler Valuation: $1,000.00 Residential Square Footage: 0 Fire Alarm Valuation: $0.00 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.198 or 1.800. -. 344. Issued By: !%'p Permittee Signature: / 7.7":„. Ca 503.639.4175 by 7:00 a.m.for the next available inspection-6Z This permit card shall he kept in a rnnapirunuc plere on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application Fire Protection System IVE,S"r FOR OFFICE USE ONLY City of Tigard Received 9" - `J g DateB GP `Z �� Permit No.: , r 3 111_, V 13125 SW Hall Blvd.,Tigard,OR 97223 �-+ �it U Plan Review Phone: 503.718.2439 Fax 503.598.1960, y Ct Date/B : OtherPetmit: �j� `� ' T I G A R D Inspection Line: 503.639.4175 . ,y r -4 Date Ready/By: ® See Paget or Internet: www.tigard-or.gov Cif SOF IIAta�tt Notified/Method: Supplemental Information ! i �Tm A: ''" a 4� i i E® l 1 9t �, �. ,�... e... ID New construction El Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ®Addition/alteration/replacement ❑Other: equipment,materials,labor,overhead,and the profit for the /y` work indicated on this application. /.; i. Citi 0 1-and 2-family dwelling Z Commercial/industrial Valuation: $ 1:1Accessory building 1:1 Multi-family Number of bedrooms: El Master builder El Other: Number of bathrooms: Total number of floors: Job site address:7244 SW Durham Rd.. New dwelling area: square feet City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet Suite/bldg./apt.no.:100 J Project name:Trane Parts TI Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the D l OIN O WORK € work indicated on this application. Add 3 new sprinkler head drops off of existing wet system Valuation: $$1,000.00 to cover new floor plan. Existing building area: square feet New building area: square feet 14 ❑ y� Number of stories: 1 Name: Type of construction: III-B Address: Occupancy groups: City/State/ZIP: Existing: B-office Phone:( ) Fax ( ) New: APyl `I ANTI % j% CQ tI CT ' 11 iON f no change Business name: All contractors and subcontractors are required to be Contact name: licensed with the Oregon Construction Contractors Board under ORS 701 and may be required to be licensed in the Address: jurisdiction in which work is being performed.If the City/State/ZIP: applicant is exempt from licensing,the following reasons apply: Phone:( ) Fax::( ) E-mail:breanna@afpsys.com ����r ��� yy� � � I,�,I}Il�l af�`€tr �e /ii/� Business name:AFP Systems Inc. �� l aserefer°to eesche "" ' Permit fee: Address:19435 SW 129th Ave State surcharge(12%of permit fee): City/State/ZIP:Tualatin,OR 97062 FLS plan review(40%of permit fee): Phone:(503)692-9284 Fax:(503)692-1186 (Due upon application submittal.) CCB lie.:67537 /, Total permit fees: Authorized signature: " Amount received: This permit application expires if a permit is not obtained Print name:Steve Frost Date:06/06/2019 within 180 days after it has been accepted as complete. Fec methodology ser by T71-County tsuliding maustry Service Board. I:\Building\PermitaPS-PermitApp_071514.doc 440-4613T(11/02/COM/WEB) • City of Tigard: Fire Protection Permit Checklist Page 2- Supplemental Information xi ':613 1.) Type of Work: 2.) Additioterati n/alon onlyql to sprinklehe r ads: 3.) Addition/alteration only to alarm devices: 0 New system Number of sprinkler heads: 3 Number of alarm devices: ® Addition or ® 1 10 heads: Affidavit required and 0 1 5 devices: Affidavit required and Alteration (3) copies of sketch showing area (3) copies of sketch showing area to existing of work within building structure of work within building structure system 0 11+ heads: Plan review required and ❑ 6+ devices: Plan review required and (3) sets of plans. (3) sets of plans. Additional description of work: Wet ® ❑ Dry Additional Standpipes Information: Hazard Group LH Density 0.10 Design Area 1500 K. Factor 5.6 Sprinkler Project Valuation: $ 1,000.00 u.' ''« j Hood r t Valuation. $l t o P ojec do Submittal shall include: Battery Calculations 0 Yes Individual Component 0 Yes Cut Sheets Fire Alarm Project Valuation: $ . ,,,__„„„,..„ 4,v,.;,,,:„,,, c.,::4L„,c:.:i„itair,;•,2„7...zv,,.:7, ,,,;:isr: „ , yili12%----„I'-_7":12,-fak,,,ittirt x ilk S.uare Foota_e: Permri,it it Fee. 0 to 2 000 $198.75 :,'",4,'i,/,*lvr �� 2 001 to 3 600 $246.45 a 3,601 to 7,200 $310.05 °i yl 7,201 and treater $404.39 Sprinkler Project Square Footage: sq. ft. v j re ' oLeC n�Rt FE y", y 7 -,,,,,,- 1 Pro ect valuation subtotal see A B &C above . $ 1000.00 Permit fee based on .ro'ect valuation see fee schedule : $ Permit fee based on s•uare foota a see D above : $ State Surcharge 12% of eermit fee : $ FLS Plan Review 40% of se rmit fee : $ TOTAL: $ X:\Permits Steve new\Tigard\trane parts TI FPS_PemutApp.doc 2 -r Ci o Tigard — � City W g o Permit No.: , • 13125 SW Hall Blvd.,Tigard,OR 97223 '`) rill C` g Phone: 503.718.2439 Fax 503.598.1960IN 1 Date Received: (f16/ 11 Inspection Line: 503.639.4175 j j N - 6 Z019 19 l 6 3. It D Internet: www.tigard-or.gov ��\S �p By: ((7 <`-t. 1 .,,,. x�r!1 CrIN FIRE SPRINkViDaPIWIT FOR ALTERATIONS OR TENANT IMPROVEMENTS (1 to 10 SPRINKLER HEADS WITHOUT PLANS) Project Name: Trane Parts TI Occupancy: B-office Job Address: 7244 SW Durham Rd.,Portland, OR 97224 Type of Construction: III-B Suite: 100 Contractor: AFP Systems Phone: 503-692-9284 Number of Proposed or Altered Heads: 3 Type: wet Hazard: light Density: 0.10 1, Steve Frost/AFP Systems Oregon Construction Contractors Board No. 67534 certify the following is true and reasonably defines the scope of work for this project: a) All work is limited to drops and armovers in a light-hazard occupancy. b) Positions of sprinkler heads relative to architectural features such as soffits, beams,partitions,walls, etc. complies with current adopted edition of NFPA 13. c) The proposed work does not require hydraulic calculations. d) Only one sprinkler head will be installed from one drop (exception: up to two heads from one drop may be installed when each head is in a separate fire area). e) The area covered per sprinkler head is limited to the spacing requirements of NFPA 13. f) Tenant improvements in a new building shall be equipped with Quick Response heads (see 2002 NFPA 13, Section 8.3.3.1 for exceptions). g) The installation shall comply with the requirements of the current adopted edition of NPFA 13. h) Piping shall not be concealed until hangers and bracing are inspected. i) Final approval shall be subject to onsite tests and inspections. In addition, I understand the following is required: • Submit(3) copies of a sketch showing the area of work within the building's structure. • Building fire protection system permit. • A copy of this • i cu : ith a copy of the sketch attached shall be available for all inspections. s:hpr 06/06/2019 Signature: Date: Print Name: Steve Frost , I:\Building\Forms\FireSprinklerAffidavit 071514.docx Page 1 of 1 City of Tigard Tel: 503.718.2439 Location: Inspection Date: 7244 SW DURHAM RD 100, TIGARD, OR, 97224 Record Type: Record ID: Commercial - Fire Protection System FPS2019-00074 Inspection Type: Inspector: 999 Sprinkler final Jeff Grove Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor