Loading...
Report (23) jos st,() C)osc\tc- c,, d. 7.5T - Project: -Untitled210 05/09/2019 Prepared By: 02:11 PM RECEIVED JUN _5 2019 7.5T CITY OF TIGARD BUILDING DIVISION Tag Cover Sheet Unit Report Certified Drawing Performance Report Unit Feature Sheet Packaged Rooftop Builder 1.49r Page 1 of 9 Unit Report For 7.5T Project: -Untitled210 05/09/2019 - Prepared By: 02:11 PM Unit Parameters Dimensions(ft. in.)&Weight(1b.)*** Unit Model: 48TCDD08A2A5-0A0G0 Unit Length. 7'4.125" Unit Size. 08(7.5 Tons) Unit Width. 4' 11.5" Volts-Phase-Hertz. 208-3-60 Unit Height 3'5.25" Heating Type. Gas ,., Total Operating Weight 870 lb Duct Cfg. Vertical Supply/Vertical Return Low Heat *** Weights and Dimensions are approximate. Weight does Round Tube Plate Fin Coils not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Gas Line Size. 1/2 Condensate Drain Line Size: 3/4 Return Air Filter Type. Throwaway Return Air Filter Quantity. 4 Return Air Filter Size: 16 x 20 x 2 Unit Configuration Medium Static Option(Belt Drive) Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging 2-Speed indoor fan motor controlled by VFD Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) 15-Year heat exchanger-Stainless Steel(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48TCDD08A2A5-0A0G0 Rooftop Unit 1 Base Unit lredwm Static Option (BeltDrive) Electromechanical control, No intake or exhaust option. 2 Speed Fan Controller (VFD) Packaged Rooftop Builder 1.49r Page 2 of 9 ... Certified Drawing for 7.5T Project: -Untitled210 05/09/2019 Prepared By: 02:11 PM NOTES: - -- 0 UNITED P.O.BOA 4605 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION UNIT S OUTDOOR J K H TECHNOLOGIES SYRACUSE,NY AND IS DELIVERED UPON THE EXPRESS CONDITION THAT THE SHOES NOTNCONSTITUTE PARTOF THESE APERFORMAGS OR NCU[EMOR 1. DIMENSIONS ARE IN INCHES, DIMENSIONS COIL TYPE CONTENTS RILL WAN DISCLOSED OR USED VITHOUT CARRIER IN I I ARE IN MILLIMETERS. 41 1/4 33 15 7/8 CARRIER 133z1 CORPoRATEON'3 WR IT7EM CONSENT. AC[[11ANCE OF COMIAACT. 48TC-A08 RTPF [10481 [658] [4031 2.S CENTER OF GRAVITY 49 3/8 37 1/4 21 7/8 CONNECTION SIZES 48TC-AD9 RTPF [12531 [9461 [7081 A 1 3/8° [35] DIA FIELD POWER SUPPLY HOLE 3.Opp,DIRECTION OF AIR FLOW 48TC-Al2 RTPF 49 3/8 37 1/4 15 1/8 40-3/B y [12531 59461 [403] [1026] B 2 1/2" [641 DIA POWER SUPPLY KNOCKOUT 48TC-D08 RTPF 41 1/4 33 15 7/8 [10481 [658] [403] " ° C 1 3/4' [51]DIA GAUGE ACCESS PLUG 48TC-109 RTPF 49 3/8 37 1/4 15 1/8 - D 7/B' [22]DIA FIELD CONTROL WIRING HOLE [12531 [9467 14031 20-3/4 E 3/4°-14 NPT CONDENSATE DRAIN 49 3/6 37 1/4 15 1/8 4 ECONOMIZER HOOD F 1/2'-14 NPT GAS CONNECTION 48TC-D12 RTPF [527] [1253] [9461 [4031 - (OPTIONAL) 3/4•-14 NPT GAS CONNECTION 48TC-D08 ACHE 41 1/4 33 23 [10481 [6581 [584.2] G 2 ' [51] DIA POWER SUPPLY KNOCK-OUT • 48TC-012 ACHE 49 3/8 37 1/4 11 ., . C [12531 [9461 1279.41 �� THRU-THE-BASE CHART (FIELD INST) RTPF-ROUND TUBE. PLATE FIN (COPPER/ALUM) - ACH%-NOVATION(ALUM/ALUM) 1 THESE HOLES REQUIRED FOR USE WITH ACCY KITS: �� 36-318 12-518 CRBTMPWR004A01: GAS THRU BASEPAN �j(/'� I� [925] [321] • •• ����®��,ii ) RETURN AIR RETURN 9%/�/ A AIR THREADED WIRE AEO'D HOLE RF CONDUIT SIZE USE SIZES(MAX.1 ,` + W 1/2" ACC. 7/8' [22.21 FILTER ACCESS PANELMIIIIII' E ALT. % 1/2" 24V 7/8' [22.21 • (TOOL-LESS) a' CONDENSATE COIL ••�Ie. �� Y 1 1/4" 1002,004) POWER 1 3/4" [44.41 CONDENSER ��DRAIN BASEPAN (131j4 37-5/8 41-3/B 2 4 (004)3/4°FPT GAS 1 3/4' [44.4] • '� SUPPLY [9551 [10271 IID �1A m77J1/liNl N SEE THRU AIR (0521 PROVIDES 3/4"FPT THOU CURB INDOOR COIL - - AAAAAU i////4/II SUPPLY 4 ACCESS PANEL �sp4II 's ( CHART AIR FLANGE 0 FITTING. HOLE SIZE: 2' [50.6] BACK 18691 t6 14 �� `-I 1412] [ass] 11 THRU-THE-BASE CHART (FIOP) H . . _ i I I21B1 .r `_ I, 4 I FOR"THRU-THE-BASEPAN•FACTORY OPTION, 4 •+ 1 FITTINGS FOR ONLY X. Y. E 2 ARE PROVIDED. 4 FOR BELOW LISTED MODELS, A FIELD t-6-1/4 SUPPLIED 1/2'ADAPTER IS REQUIRED 4 FLUE [159] 4R BETWEEN BASE PAN FITTING AND GAS VALVE: 29-5/8 [10D] FLUE —.- ~3-1/4 4BHCD,S4D8 [151] 14 r (83] (3561 TOP 25-1/2 41 [647] H 1-1/4 [321 11-7/8 4-5/8 [302] [718] __ _ __ ELECTRICAL CONTROL BOX —I Ak DISCONNECT FILTER LOCATION ACCESS PANEL E STD. CONDENSER B, CONDENSATE Y COIL G • DRAIN OPTIONAL INDOOR BLOWER I J FACTORY ® ACCESS I _ OPTIONAL FACTORY , 27-7IB INSTALLED y OUTSIDE INSTALLED DDISCONNECT 27'3/4 /� AIR CONVENIENCE kg' )709] • F HANDLE 13-1/8 [706] • 26 OUTLET Cz [334] �� SUPPLY AIR [659] HANDLE4411 E1-133.1. .— =�8 (1688 1 (TOO I • u SI I : • �O [1578 = _Ill"\\.4;FLOw • 3-3/4 2-5/8 6-5/8 74-3/B[95] 59-1/21214] [167] [117] 61158[1510] CTYP URB [940] [214] [962]842-3/B [155] [113]LEFT WIDTH - 88-1/8 [11751 BAROMETRIC [2238] ABRPLY * RETURN RELIEF FRONT ♦ RIGHTAIR SHEET DATE SUPEACEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REV 1 OF 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F Packaged Rooftop Builder 1.49r Page 3 of 9 Certified Drawing for 7.5T Project: -Untitled210 05/09/2019 Prepared By: 02:11PM UNITED P.O.BOY ABOR THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SUBMISSION OF THESE°RAVINGS OR DOCUMENTS TECHNOLOGIES SYRACUSE,NY AND IS DELIVER[°UPOY THE EMPRESS CONDITION iHAT TIE ODES MOT CONSTITUTE PART PERFORMANCE OR COMTEYIS BELL NOT BE O11[LOSFD OR 3535 YITXDUT 3353155 ACCEPTANCE OF CONTRACT. OUTDOOR STD. UNIT CORNER CORNER COi[NER CORNER C G CARRIER 13211 CORPORATIONS WHITEN CONSENT. UNIT COIL TYPE WEIGHT AAY WEIGHT(Al WEIGHT IBl WEIGHT IU WEIGHT(D) LBS. KG. LBS. KG. LBS. KG. LBS, KG. LBS. KG. x Y Z 48TC-308 RTPF 780 354 178 81 158 72 209 95 236 107 /1 1/2 [1054] 33 1/8[860] 20 1/2 [5211 NYA STANDARD UNIT WEIGHT IS WITH LOW GAS NEAT AND WITHOUT PACKAGING. 48TC-309 RTPF 920 418 212 96 183 83 243 110 282 128 40 7/8[1038] 34[864] 23 1/8[587] FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. 48TC-Al2 RTPF 930 422 216 98 196 89 247 112 272 123.5 42[10671 33 1/8[8411 24 1/4[616] 48TC-008 RTPF 835 319 164 74.5 17D 77.2 255 115.8 246 111.7 44 7/8[1140] 35 5/8 19051 19 3/8[4921 48TC-009 ATPF 930 422 228 103.5 181 85 232 105.3 283 128.5 39 3/4[10101 32 7/8[8351 18 5/8[413] 48TC-012 RTPF 940 427 231 104.9 189 85.8 234 106.2 286 129.8 39 3/4[10101 33 1838] 18 1/2 [41D] 48TC-008 MOH 805 365.5 160 72.6 153 69.5 24D 109 260 118 43[1092] 36 3/8[9241 20 3/8[517.7] 48TC-012 UCH 895 406.3 185 84 176 79.9 260 118 274 124.4 42 7/8[10891 35 1/2 [9021 22 7/8[5811 RTPF-ROUND TUBE. PLATE FIN (COPPER/ALUM) CORNER A CORNER B UCH-NOVATION(ALUM/ALUM) /IIIY(�/ I v L�l l n r,iiii; s CORNER D CORNER C TOP 1 x • 1. = . m• ZI. II • o Io IAOO = MINI : 00.1 FRONT SHEET DATE SUPERCEDES 48TC 08-12 SINGLE ZONE ELECTRICAL REY 20F2 03-08-10 11-24-08 COOLING WITH GAS HEAT 48TM500985 F Packaged Rooftop Builder 1.49r Page 4 of 9 • - r \Certified Drawing for 7.5T Project: -'Untitled210 05/09/2019 Prepared By: 02:11 PM Service Clearance e -,,---•-,,---• s'a D C11247 LOCATION_ DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel 36-in(914 mm) •If dimension-B is 12-in(305 mm) A i&in(457 mm) •No disconnect,convenience outlet option _•Recommended service clearance(use electricscrewdriver) 12-in(305 mm) •Minimum clearance(use manual ratchetscrewdriver) 36-in(914 mm) •Unit has economizer B 12-in(305 mm) •If dimension-A is 36-in(914 mm) Special •Check for sources of flue products within 10-ft of unit fresh air intake hood C 36-in(9I4 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) D 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. Chassis 3-4a Packaged Rooftop Builder 1.49r Page 5 of 9 f Performance Summary For 7.5T Project: —Untitled210 05/09/2019 - Prepared By: 02:11 PM Part Number:48TCDDO8A2A5-0A0G0 ARI EER. 11.00 IEER. 12.8 Base Unit Dimensions Unit Length. 88.1 in Unit Width. 59.5 in Unit Height 41.3 in Operating Weight Base Unit Weight 835 lb Medium Static Option (Belt Drive). 15 lb 2 Speed Fan Controller (VFD). 20 lb Total Operating Weight 870 lb Unit Unit Voltage-Phase-Hertz. 208-3-60 Air Discharge- Vertical Fan Drive Type. Belt Actual Airflow. 3000 CFM Site Altitude- 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB- 80.0 F Evaporator Entering Air WB• 67.0 F Entering Air Enthalpy. 31.44 BTU/lb Evaporator Leaving Air DB. 58.7 F Evaporator Leaving Air WB. 57.6 F Evaporator Leaving Air Enthalpy 24.76 BTU/lb Gross Cooling Capacity 90.10 MBH • Gross Sensible Capacity' 68.90 MBH Compressor Power Input 6.40 kW Coil Bypass Factor 0.092 Heating Performance Heating Airflow- 3000 CFM Entering Air Temp. 70.0 F Leaving Air Temp. 101.8 F Gas Heating Input Capacity 125.0 MBH Gas-Heating Output Capacity. 103.0 MBH Temperature Rise. 31.8 F Thermal Efficiency(%)• 82.0 Supply Fan External Static Pressure. 0.75 in wg Fan RPM. 804 Fan Power 1.87 BHP NOTE- Selected IFM RPM Range: 733-949 Electrical Data Voltage Range- 187-253 Compressor#1 RLA. 13.6 Compressor#1 LRA. 83 Compressor#2 RLA. 13.6 Compressor#2 LRA- 83 Indoor Fan Motor Type. MED Indoor Fan Motor FLA- 8.4 Combustion Fan Motor FLA(ea). 0.48 Packaged Rooftop Builder 1.49r Page 6 of 9 Performance Summary For 7.5T • Project: -•Untitled210 05/09/2019 Prepared By: 02:11 PM • Power Supply MCA. 43 Power Supply MOCP(Fuse or HACR). 50 Disconnect Size FLA. 45 Disconnect Size LRA. 227 Electrical Convenience Outlet. None Outdoor Fan[Qty/FLA(ea)]. 2/1.5 Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 98.5 95.6 85.8 125 Hz 91.7 86.7 84.3 250 Hz 78.6 74.2 80.5 500 Hz 71.3 66.9 78.7 1000 Hz 68.0 64.1 76.4 2000 Hz 66.7 59.2 72.7 4000 Hz 68.0 58.7 68.3 8000 Hz 70.7 58.2 65.1 A-Weighted 80.0 75.0 82.0 Advanced Acoustics 0 4 0. 0 0 1,41 Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 85.8 84.3 80.5 78.7 76.4 72.7 68.3 65.1 89.6 Lw B _59.6 68.2 71.9 75.5 76.4 73.9 69.3 64.0 81.4 LwA C 53.4 51.9 48.1 46.3 44.0 40.3 35.9 32.7 57.2 Lp D 27.2 35.8 39.5 43.1 44.0 41.5 36.9 31.6 49.0 LpA Legend A Sound Power Levels at Unit's Acoustic Center, Lw Packaged Rooftop Builder 1.49r Page 7 of 9 1 r Performance Summary For 7.5T 02:11 PM Project: -Untitled210 05/09/2019 ' Prepared By: B A-Weighted Sound Power Levels at Units Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant efforthas been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve r fit �, i,I , 1liTii � 1 20 ia1 r IM ip '16 �q ch 14 7O0RPM �i � � ii illi kry I �" ,, i,,,,.4:,: l + fit I 'y i .i - llrip,,,ikiiils!!!PICifliltii oilii • 08 3 �a.r U , rro3.00BHP�C4IG-i,';.);':,:' 'It " ' ' ( 2...:4OORPM ,! rr tGf (14 02 iii III co 00 04 Q$ 12 16 20 24 28 32 36 40 44 Airibw(CFM-1ho asands) RPM=804 BHP=1.87 MaxirnumRPM=1400 Maximwn BHP=4.70 Note:Please contactalicationengineeringforselectionsoutsidethe shadedregion SC-System Ctiuve RP-RatedPoint Packaged Rooftop Builder 1.49r Page 8 of 9 Unit Feature Sheet for 7.5T Project: —Untitled210 05/09/2019 - Prepared By: 02:11PM ( Carrier WeatherMaker' — 48TC PACKAGED ROOFTOP GAS HEATING/ELECTRIC COOLING UNITS 6,7.5,8.5,10,12.5,15 TONS STANDARD FEATURES INCLUDE: • Puron(R-410A)HFC refitterallt capacity control on 07 models , • cooling on 08-16 models •Two-stage/two-circuit - 08 09 12 models •Two-stage/single cooling capacity control on • EER's up to 11.1 • IEERs up to 12.8 • Energy Saving Staged Air Volume(SAV")2-speed indoor fan motor 7'41 on two circuit(08-16)and 07 models.Requiredrin U Not available or required to meet DOE on 48 " f i:744.}:rfj models'V0;41,097152. ',7tz-Z14,1 ,11154,zf . •Scroll compressors with internallinernetenbreakandoverload protection •Andra!'"and or TXV refrigerant- • Exclusive non-corrosive composite condensatellfpan in accordance with ASHRAE Standard 62 sloping _ center drain - 4 • Standard cooling operation up to 115 F(46°C)and down to 40°F(4°C) -down to 25°F C)withranterer start kit. - panels tested to • Pre-painted exterior panels and primer-coated 500 hours salt spray protection logic diagnostics with LED •Exclusive IGC solid-state control for on-boardand saving indoor error code designation burner control energy Optional Louvered Hail Guard Shown fan motor delay • Induced draft gas heat combustion design • Redundant gas valves with up to two stages of .ng • Lowpressure and high pressure switch Pro ected MAINTENANCE FEATURES: PiJron •Access panels with easy griP handles nit access panels COM I Innovativeeasy starting,no-strip screws onu •Two-inch disposable return air filters and Tool-less filter access door WEATHERMAKER SERIES •Central terminal board facilitating simple safety circuit troubleshooting arid s.rripktled control box arrangement WeatherMaker(48TC)units are one-piece gas heating,electric INSTALLATION FEATURES: cooling units that are pre-wired and charged with Puron .Thrthe-bonom power entry capability (R-410) refrigerant They are factory tested in both heating • Single peed gas arid electric connections and cooling modes, and rated in accordance with AFIRI • Full perimeter base_ raavewithabutoilt-atminggeigtat airnowadaptersforarabfo;iiizostuntiotsna, Standard 340/360 (07-16 sizes). therMaker units are • Field convertible from. rho designed in accordance with UL StandardWa1995,and listed by (16 size models require field installed supply duct cover) the Undenwiters"Laboratories. STANDARD WARRANTY: • 10-year heat exchanger-15-year stainless steel option Approved and certified by: • 5-year compressor • 1-year parts • 3-year parts on Novation Condenser PAS—where available • Many optional upgrades also available roor rt 11)US tkakkrik414N frorlfed rAkAsk kkalfro rkirartaktark k.traprfack ,rk kr wer.k... OPTIONS INCLUDE BUT ARE NOT LIFOTEDGTcnOn:nala C • Premierlink"and RTU Open Multi-Protocol DO Supply and Return AirSmguards• olteOetectors,high static motors • Louvered condenser coilmice outlet op tions• Economizer disconnect and convent WO". td• mar rkrilkrOnk4,2 • Stainless Steel heat exchanger option • Hun."-m14 adaptive deUtanicKeabon system aavailable on ail modeis wilheRTPf condenser coils-Motor Master I controller included • Hinged access panels • Condensate overflow switch • VFD had field accessory display kit Far a carnplatt Eat a tfa mad attataaaes Oder la et Product Cala Catabg fay Si,WV Page 9 of 9 Packaged Rooftop Builder 1.49r