Report (31) ME,G2r0\q 101S\,o5�. . 0 TRANE® Submittal Prepared For: Date:January 22, 2019 HVAC Inc. Diane Gardner Job Name: Jaguar Land Rover Trane U.S. Inc. is pleased to provide the enclosed submittal for your review and approval. Product Summary Qty Product 10 Packaged Gas/Electric Rooftop Units The attached information describes the equipment we propose to furnish for this project,and is submitted for your approval. Product performance and submittal data is valid for a period of 6 months from the date of submittal generation. If six months or more has elapsed Chris Smith between submittal generation and equipment release,the product Trane performance and submittal data will need to be verified. It is the 7257 SW Kable Lane customer's responsibility to obtain such verification. Portland, OR 97224-7181 Phone: (503) 431-2561 Email: chrisd.smithc trane.com JAJOBS1124170190161RTU Submittal Rev 3.doc Table of Contents Product Summary 1 5-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop(Items Al -A3) Tag Data 3 Product Data 3 Performance Data 4 Mechanical Specifications 5 Unit Dimensions 7 Weight, Clearance& Rigging Diagram 14 Accessory 20 3-4 Ton, 15 Ton Packaged Gas/Electric Rooftop Units(Items B1 -B4) Tag Data 24 Product Data 24 Performance Data 25 Mechanical Specifications 26 Unit Dimensions 29 Weight, Clearance& Rigging Diagram 34 Accessory 39 Field Installed Options - Part/Order Number Summary Packaged Gas/Electric Rooftop Units 44 Curb Cut Sheets 45 Jaguar Land Rover January 22,2019 Tag Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop (Qty: 4) Item Tag(s) Qty Description Model Number Al RTU-S-3 1 10 Ton R410A PKGD Unitary Gas/Electric YSC120H4ELA A2 RTU-S-5, 2 6 Ton R410A PKGD Unitary Gas/Electric YSC072H4ELA RTU-S-9 A3 RTU-S-7 1 5 Ton R410A PKGD Unitary Gas/Electric YSC060G4ELB Product Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop All Units DX cooling, gas heat Convertible configuration 460/60/3 Electro mechanical controls Low gas heat Economizer Dry Bulb 0-100%with Barometric Relief Spring Isolation Curb (Fld) Wired Thermostat (Fld) Item: Al Qty: 1 Tag(s): RTU-S-3 10 Ton Item: A2 Qty: 2 Tag(s): RTU-S-5, RTU-S-9 6 Ton Single compressor Item: A3 Qty: 1 Tag(s): RTU-S-7 5 Ton FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Pogo 3 of 48 Others Jaguar Land Rover January 22,2019 Performance Data -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Tags RTU-S-3 RTU-S-5, RTU-S-7 RTU-S-9 Design Airflow(cfm) 4000 2400 2000 Airflow Application Downflow Downflow Downflow Cooling Entering DB (F) 82.10 82.23 82.32 Cooling Entering WB (F) 69.06 69.19 69.28 Ambient Temp (F) 95.00 95.00 95.00 Evap Coil Leaving Air Temp (DB) (F) 59.98 61.61 59.86 Evap Coil Leaving Air Temp (WB) (F) 59.83 59.18 59.86 Cooling Leaving Unit DB (F) 61.51 63.13 61.85 Cooling Leaving Unit WB (F) 60.39 59.74 60.59 Gross Total Capacity(MBh) 120.06 77.89 62.54 Gross Sensible Capacity(MBh) 95.57 53.44 49.18 Gross Latent Capacity(MBh) 24.48 24.45 13.36 Net Total Capacity(MBh) 114.68 74.52 59.79 Net Sensible Capacity(MBh) 90.20 50.07 46.44 Heating EAT (F) 66.78 66.58 66.43 Heating LAT (F) 94.88 91.88 96.73 Heating Delta T (F) 28.10 25.30 30.30 Input Heating Capacity(MBh) 150.00 80.00 80.00 Output Heating Capacity(MBh) 120.00 64.80 64.80 Output Heating Cap. w/Fan (MBh) 125.38 68.17 67.79 Design ESP (in H2O) 0.810 0.730 0.640 Component SP (in H2O) 0.260 0.110 0.180 Indoor mtr operating power(bhp) 1.88 1.05 0.99 Indoor RPM (rpm) 1436 893 1150 Indoor Motor Power(kW) 1.40 0.78 0.74 System Power(kW) 10.59 6.64 5.10 IPLV @ AHRI (IPLV) 12.7 12.7 14.0 MCA(A) 22.00 17.00 13.00 MOP (A) 25.00 25.00 15.00 Evaporator fan FLA(A) 3.60 1.60 0.00 Condenser fan FLA(A) 1.50 1.50 0.00 Evaporator face area(sq ft) 12.36 9.89 6.98 Evaporator rows (Each) 4.00 3.00 2.00 Evaporator fin spacing (Per Foot) 192 192 192 Evaporator face velocity(ft/min) 324 243 287 1 Min. unit operating weight(Ib) 1058.0 710.0 522.0 Max. unit operating weight(lb) 1384.0 1045.0 797.0 Fan motor heat(MBh) 5.38 3.37 2.74 Dew Point (F) 59.74 57.70 59.88 Rated capacity(AHRI) (MBh) 113.00 71.00 48.00 Exhaust fan power(kW) - 0.65 0.65 Refrig charge (HFC-410A) -ckt 1 (Ib) 5.6 5.5 4.8 ASHRAE 90.1 Yes Yes Yes Saturated Suction Temp Circuit 1 (F) 51.76 50.94 52.79 Saturated Discharge Temp Circuit 1 (F) 121.79 115.24 117.38 IEER() 12.70 12.70 14.00 EER @ AHRI Conditions (EER) 11.2 11.2 12.0 Total Static Pressure(in H2O) 1.070 0.840 0.820 Length (ft) 7.39 7.39 5.82 Width (ft) 4.44 4.44 3.69 Height(ft) 3.91 3.41 3.41 Heating Stages 2 1 2 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 4 of 48 Others Jaguar Land Rover January 22,2019 Mechanical Specifications -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 4 Tag(s): RTU-S-3, RTU-S-5, RTU-S-9, RTU-S-7 General The units shall be convertible airflow. The operating range shall be between 115°F and 0°F in cooling as standard from the factory for units with microprocessor controls. Operating range for units with electromechanical controls shall be between 115°F and 40°F. Cooling performance shall be rated in accordance with ARI testing procedures. All units shall be factory assembled, internally wired, fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation, and control sequence before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be cULus listed and labeled, classified in accordance for Central Cooling Air Conditioners. Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM 8117. Cabinet construction shall allow for all maintenance on one side of the unit. Service panels shall have lifting handles and be removed and reinstalled by removing two fasteners while providing a water and air tight seal. All exposed vertical panels and top covers in the indoor air section shall be insulated with a cleanable foil-faced, fire-retardant permanent, odorless glass fiber material. The base of the unit shall be insulated with 1/8 inch, foil-faced, closed-cell insulation.All insulation edges shall be either captured or sealed. The unit's base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8 inch high downflow supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting, with forklift capabilities on three sides of the unit. Unit Top The top cover shall be one piece construction or, where seams exist, it shall be double-hemmed and gasket-sealed. The ribbed top adds extra strength and enhances water removal from unit top. Filters Throwaway filters shall be standard on all units. Optional 2-inch MERV 8 and MERV 13 filters shall also be available. Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of unit nameplate voltage. Internal overloads shall be provided with the scroll compressors. Dual compressors are outstanding for humidity control, light load cooling conditions and system back-up applications. Dual compressors are available on 7%-10 ton models and allow for efficient cooling utilizing 3-stages of compressor operation for all high efficiency models. Indoor Fan The following units shall be equipped with a direct drive plenum fan design (T/YSC120F,T/YHC074F, T/YHC092F,T/YHC102F, 120F). Plenum fan design shall include a backward-curved fan wheel along with an external rotor direct drive variable speed indoor motor. All plenum fan designs will have a variable speed adjustment potentiometer located in the control box. 3 to 5 ton units (high efficiency 3-phase with optional motor)are belt driven, FC centrifugal fans with adjustable motor sheaves. 3 to 5 ton units (standard and high efficiency 3-phase) have multispeed, direct drive motors.All 6 to 8%ton units(standard efficiency)shall have belt drive motors with an adjustable idler-arm assembly for quick-adjustment to fan belts and motor sheaves.All motors shall be thermally protected. All 10 tons, 6 ton (074), 7%to 8%(high efficiency) units have variable speed direct drive motors.All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor shall be permanently lubricated and shall have built-in thermal overload protection. Evaporator and Condenser Coils Internally finned, 5/16"copper tubes mechanically bonded to a configured aluminum plate fin shall be standard. Evaporator coils are standard for all 3 to 10 ton standard efficiency models. Microchannel condenser coils are standard for all 3 to 10 ton standard efficiency models and 4, 5, 6, 7.5, 8.5 ton high efficiency models. The microchannel type condenser coil is not offered on the 4 and 5 ton dehumidification model. Due to flat streamlined tubes with small ports, and metallurgical tube-to-fin bond, microchannel coil has better heat transfer performance. Microchannel condenser coil can reduce system refrigerant charge by up to 50% because of smaller internal volume, which leads to better FLD Furnished by Trane U.S.las./Installed by Equipment Submittal- Page 5 of 48 Others Jaguar Land Rover January 22,2019 compressor reliability. Compact all-aluminum microchannel coils also help to reduce the unit weight. These all aluminum coils are recyclable. Galvanic corrosion is also minimized due to all aluminum construction. Strong aluminum brazed structure provides better fin protection. In addition, flat streamlined tubes also make microchannel coils more dust resistant and easier to clean. Coils shall be leak tested at the factory to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 600 psig. The assembled unit shall be leak tested to 465 psig. The condenser coil shall have a patent pending 1+1+1 hybrid coil designed with slight gaps for ease of cleaning.A plastic, dual-sloped, removable and reversible condensate drain pan with through-the-base condensate drain is standard. Controls Unit shall be completely factory-wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device.A choice of microprocessor or electromechanical controls shall be available. Microprocessor controls provide for all 24V control functions.The resident control algorithms shall make all heating, cooling, and/or ventilating decisions in response to electronic signals from sensors measuring indoor and outdoor temperatures. The control algorithm maintains accurate temperature control, minimizes drift from set point, and provides better building comfort.A centralized microprocessor shall provide anti-short cycle timing and time delay between compressors to provide a higher level of machine protection. 24-volt electromechanical control circuit shall include control transformer and contactor High Pressure Control All units include High Pressure Cutout as standard. Phase monitor Phase monitor shall provide 100% protection for motors and compressors against problems caused by phase loss, phase imbalance, and phase reversal. Phase monitor is equipped with an LED that provides an ON or FAULT indicator. There are no field adjustments. The module will automatically reset from a fault condition. Refrigerant Circuits Each refrigerant circuit offer thermal expansion valve as standard. Service pressure ports, and refrigerant line filter driers are factory-installed as standard.An area shall be provided for replacement suction line driers. Gas Heating Section The heating section shall have a progressive tubular heat exchanger design using stainless steel burners and corrosion resistant steel throughout. An induced draft combustion blower shall be used to pull the combustion products through the firing tubes. The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat/zone sensor. Units shall be suitable for use with natural gas or propane(field-installed kit)and also comply with the California requirement for low NOx emissions (Gas/Electric Only). Economizer This accessory shall be available with or without barometric relief. The assembly includes fully modulating 0-100 percent motor and dampers, minimum position setting, preset linkage, wiring harness with plug, spring return actuator and fixed dry bulb control. The barometric relief shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Optional solid state or differential enthalpy control shall be available for either factory or field installation. The economizer arrives in the shipping position and shall be moved to the operating position by the installing contractor. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 6 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-S-3 TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) 3/4"-14 NPT DIA.HOLE I�IGI;;: Q�i CONDENSER COIL 4 1/4'' %k t L:ii: 7 5/8" .; - SERVICE UNIT CONTROLGAUGERE 7/8"DIA.HOLE � /\ / PORTW1ACCESS 1 3/8"DIA.HOLE 47 7/8 ��i II „,'��. UNIT POWER WIRE 1/2”NPT GAS CONNECTION (80MBH&120MBH) 3/4"NPT GAS CONNECTION CONTROL AND COMPRESSOR ACCESS PANEL (150MBH,200MBH&250MBH) PACKAGED GAS/ELECTRICAL THROUGH THE ISOMETRIC VIEW BASE CONDENSATES 4 1/8" 27 5!8"--1 NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY ALL DIMENSIONS WITH INSTALLER DOCUMENTS BEFORE INSTALLATION. ��1 I---•--1 ----� * 4 33" �� Ii SUPPLY 321/8" \ / RETURN 1 4" —171/2"---97/8" o-171/2"-- o-35/8" PLAN VIEW UNIT DIMENSION DRAWING 46 7/8 HORIZONTAL RETURN 321/4" 24 AIR FLOW 23 7/8" SUPPLY V I1/2" , !. 1 9 8 5 1111 11 11 - 19 1/4" 41 9 3/8" - 16 3/4" - 3 7/8" 4 1/4" - II CONDENSATE 5 5/8" - - 88 5/8" 7 5/8" - - PACKAGED GAS/ELECTRICAL 531/4" DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 7 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-S-3 'ELECTRICAL/GENERAL DATA 'GENERAL(2114116 HEATING PERFORMANCE Model: YSC120H Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Heating Model: Low Unit Primary Voltage: 460 MFS: N/A Unit Secondary Voltage — MCB: N/A Heating Input(BTU): 150,000/105,000 Unit Hertz: 60 Heating Output(BTU): 120,000/84,000 Unit Phase: 3 No.Burners: 3 No.Stages 2 EER 11.3 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 22.0 MCA: N/A Natural Gas(Min/Mix): 4.5/14 MFS: 25.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 3/4" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. 1 Number N/A Number. N/A Horsepower: 2.75 Horsepower: N/A Horsepower: N/A Motor Speed(RPM): — Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 3.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 2 Number: 1 Horsepower: 4.8/3.7 Horsepower: 0.75 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 8.2/6.1 Phase: 1 Locked Rotor Amps: 66.1/41.0 Full Load Amps: 1.5 Locked Rotor Amps: 6.1 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway Horsepower N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 4 Circuit#1 5.6 lb Full Load Amps: N/A Recommended 20"x25"x2" Circuit#2 4.4 lb Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. L_. - FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 8 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 2 Tag(s): RTU-S-5, RTU-S-9 /—TOP PANEL EVAPORATOR SECTION ACCESS PANEL CONDENSER FAN CONDENSATE DRAIN(ALT) 1 `i111 3/4"-14 NPT DIA.HOLE time. J/ ``�� `/ / CONDENSER COIL 41/4" N. ; 275/8 \ " ' �/ UNIT CONTROL WIRE 7/8"DIA.HOLE 47718 0 0 SERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE 00_,' / UNIT POWER WIRE 1/2"NPT GAS CONNECTION CONTROL AND COMPRESSOR ACCESS PANEL (80MBH&120MBH) 3/4"NPT GAS CONNECTION (150MBH,200MBH&25OMBH) THROUGH THE BASE CONDENSATE 27 5/8 �_9 , NOTES: 4 1/8" 1.THRU-THE-BASE ELECTRICAL AND GAS IS NOT STANDARD ON ALL UNITS. i , 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WTH INSTALLER DOCUMENTS BEFORE INSTALLATION (rJtt 33" 32 1/8" �� SUPPLY RETURN - 17 1/2" - 9 7/8" - 17 1/2" - 1---3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 1111 RETURN 34 1/q" 407/8" HORIZONTAL SUPPLY 23 7/8" AIR FLOW 181/2" 1111111 5/8" 19 1/4" A 9 3/8" 16 3/4" J__37/8•• —�.��� �" 4 1/4" - II CONDENSATE 5 5/8" 88 5/8" 7 5/8" - - 53 1/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWING FLD=Fumished Trane L.S.Inc.IInstalled by Equipment Submittal __.n _ - - Pa -9 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 2 Tag(s): RTU-S-5, RTU-S-9 'ELECTRICAL/GENERAL DATA 'GENERAL 121(41161 HEATING PERFORMANCE Model: YSC072H Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A Unit Primary Voltage: 460 MFS: N/A Heating Model: Low Unit Secondary Voltage -- MCB: N/A Heating Input(BTU): 80,000 Unit Hertz: 60 Heating Output(BTU): 64,000 Unit Phase: 3 No.Burners: 2 No.Stages 1 EER 11.2 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 17.0 MCA: N/A Natural Gas(Min/Mix): 4.5/14.0 MFS: 25.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 25.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number 1 Number: N/A Number: N/A Horsepower: 1.0 Horsepower: N/A Horsepower: N/A Motor Speed(RPM): -- Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 3 Phase N/A Phase N/A Full Load Amps: 1.6 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: 16.1 Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number: 1 Horsepower: 5.6 Horsepower: 0.70 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 10.6 Phase: 1 Locked Rotor Amps: 75.0 Full Load Amps: 3.3 Locked Rotor Amps: 12.3 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway yp Factory Charge MHotor eN/A FNumber Yes Circuit#1 5.5 lb Motor aSpeedAmps: N/A Recom Circuit#2 N/A Full Load Amps: N/A Recommended 16"x25"x2" Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 10 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 TOP PANEL EVAPORATOR CONDENSER FAN SECTION ACCESS PANEL * 34-14 NSATE DRAIN NPT D A HOLE(ALT) II zz CONDENSER COIL 41/4" �\ 23 9/16" � JL UNIT CONTROL WIRE 7/8"DIA.HOLE 42 1/4 jSERVICE GAUGE PORT ACCESS 1 3/8"DIA.HOLE UNIT POWER WIRE CONTROL AND COMPRESSOR ACCESS PANEL THROUGH THE BASE 1/2"NPT GAS CONNECTION CONDENSATE - 231/2" NOTES: . 4 3/16" 1.THRU-THE-BASE GAS AND ELECTRICAL IS NOT STANDARD ON ALL UNITS. --- I 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WTH INSTALLER DOCUMENTS BEFORE INSTALLATION r- , ( OW 1,, --- 1/4M I 77 %```ro �I, 18" RETURN 24" �, SUPPLY `�I I 0 —4 - 15 1/2" - 9 1/4" - 14" - o-3 5/8" PLAN VIEW UNIT DIMENSION DRAWING 40 7/8" RETURN 231/4" HORIZONTAL mor SUPPLY 14 3/4" AIRFLOW 20 1/4" 43/4'III " 9b8 55/8" IHOI' -17 1/4" 8 7/8" -131/4" - 16" I' 4 1/4" - 69 7/8" 5 9/16" CONDENSATE 7 5/8" 44 1/4" PACKAGED GAS/ELECTRICAL DIMENSION DRAWNG FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal --- �g— Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 llli 1 ® kikRETURN '' 4 ,"/ 3/4"-14 NPT ®® DRAIN CONNECTION 239/16" 4\1/4" ISOMETRIC-PACKAGED COOLING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 12 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 'ELECTRICAL/GENERAL DATA GENERAL 121t4161 HEATING PERFORMANCE Model: YSC060G Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: 414-506 MCA: N/A HeatingModel: Low Unit Primary Voltage: 460 MFS: N/A Unit Secondary Voltage — MCB: N/A Heating Input(BTU): 80,000/56,000 Unit Hertz: 60 Heating Output(BTU): 64,800/45,360 Unit Phase: 3 No.Burners: 2 No.Stages 2 EER/SEER 12.0/14.0 Standard Motor Field Installed Oversized Motor 'Gas Inlet Pressure MCA: 12.0 MCA: N/A Natural Gas(Min/Mix): 4.5/14.0 MFS: 15.0 MFS: N/A LP(Min/Max) 11.0/14.0 MCB: 15.0 MCB: N/A Gas Pipe Connection Size: 1/2" INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. 1 Number: N/A Number. N/A Horsepower: 1.0 Horsepower: N/A Horsepower: N/A Motor Speed(RPM): -- Motor Speed(RPM): N/A Motor Speed(RPM): N/A Phase 1 Phase N/A Phase N/A Full Load Amps: 2.5 Full Load Amps: N/A Full Load Amps: N/A Locked Rotor Amps: _ Locked Rotor Amps: N/A Locked Rotor Amps: N/A COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: 1 Number 1 Horsepower: 4.3 Horsepower 0.40 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 7.1 Phase: 1 Locked Rotor Amps: 52.0 Full Load Amps: 0.7 Locked Rotor Amps: 2.6 POWER EXHAUST ACCESSORY (3) FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type Phase: N/A Type: Throwaway Horsepower N/A Furnished: Yes Factory Charge Motor Speed(RPM): N/A Number 2 Circuit#1 4.8 lb Full Load Amps: N/A Recommended 20"x35"x2" Circuit#2 N/A Locked Rotor Amps: N/A NOTES: 1.Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2.Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3.Value does not include Power Exhaust Accessory. 4.Value includes oversized motor. 5.Value does not include Power Exhaust Accessory. 6.EER is rated at AHRI conditions and in accordance with DOE test procedures. FLD=Furnished by Trane U.S.Inc.t Installed by Equipment Submittal Page 13 of 48 Others Jaguar Land Rover January 22,2019 Weight,Clearance& Rigging Diagram -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-S-3 INSTALLED ACCESSORIES NET WEIGHT DATA LACCESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER O Oi MANUAL OUTSIDE AIR DAMPER BAROMETRIC RELIEF OVERSIZED MOTOR n _. ___a �‘ BELT DRIVE MOTOR ��U 1 POWER EXHAUST �``�`OI>>� THROUGHT THE BASE ELECTRICAL/GAS(FIOPS) \\`````10,1" UNIT MOUNTED CIRCUIT BREAKER(FIOPS) `� • UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOPS) B O HAIL GUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY - SHIPPING NET OA 345.0 lb © 258.0 lb (E)LENGHT (F)WIDTH 1156.0 lb 1058.0 lb © 242.0 lb O 213.0 lb 41" 23" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation fr/ / of unit. / 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+1-10%of the nameplate weight.. • • • • • • 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. /441 ossisstiss4.4.4% ' . (/.1. ."--'7' A E \ p e \��'0%� F iol o /ill , PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 14 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al -A3 Qty: 4 Tag(s): RTU-S-3, RTU-S-5, RTU-S-9, RTU-S-7 1 5/16" 5 15/16" 1 3/8" ,- (MQ)(T11)(W0)(T^)(R)(g.)(eu) 1 ':' i- 111 4 5/8" J BB BB BB: c oun sa. ( v ) ®® 0S 4,0 (oK)(0)r (a) (k+r'tadks ) (®)(X) . FRONT VIEW RIGHT SIDE VIEW 1/8"--=- o- 2 3/8" III 3 3/8" 6 I I`IIJI II 9/16" `, 0 1/4 ' M - 2 13/16" - BACK VIEW BAYSTAT152A PROGRAMMABLE TOUCHSCREEN THERMOSTAT-ACCESSORY FLD=Furnished by Trane(LSinc—llnstallar1by_ _EquipmentPaye 15 of 48 Others Jaguar Land Rover January 22,2019 Weight,Clearance& Rigging Diagram -3-10 Ton R-410APKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 2 Tag(s): RTU-S-5, RTU-S-9 INSTALLED ACCESSORIES NET WEIGHT DATA LAC CESSORY WEIGHTS ECONOMIZER 36.0 lb MOTORIZED OUTSIDE AIR DAMPER CD T Oi MANUALOUTSIDE AIR DAMPER \\ BAROMETRIC RELIEF � OVERSIZED MOTOR D, _ _ ar �`` BELT DRIVE MOTOR tiff. ��� POWER EXHAUST e c �```�` ��Jl�� THROUGHT THE BASE ELECTRICAUGAS(FIOPS) e `��l UNIT MOUNTED CIRCUIT BREAKER(FIOPS) ��`� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) �� HINGED DOORS(FIOPS) O HAIL GUARD B SMOKE DETECTOR,SUPPLY/RETURN NOVAR CONTROL PACKAGED GAS/ELECTRICAL STAINLESS STEEL HEAT EXCHANGER CORNER WEIGHT REHEAT ROOF CURB BASIC UNIT WEIGHTS I CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET AO 222.0 lb © 121.0 lb (E)LENGHT (F)WIDTH 805.0 lb 710.0 lb © 217.0 lb OD 150.0 lb 41" 22" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. ill 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/_10%of the nameplate weight.. 6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. fr//' 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. [ -,.... 1111111. , '‘. 1_,...„7..- / ., ......-- ..<1 :Ns, • E Mt J., ,,,..,,,.****1 ,'I F i \ +arm PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 16 of 48 Others Jaguar Land Rover January 22,2019 - Weight, Clearance& Rigging Diagram -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A2 Qty: 2 Tag(s): RTU-S-5, RTU-S-9 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" 1 iiiiiii Al 1 /7. a, . ® DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING . I UNIT OUTLINE I I 7 H48" 53 1/4" I I 46" .L:, Lia7 _ -_____i_i _ _ i 88 5/8" PACKAGED GAS/ELECTRIC DOWNFLOWTYPICAL ROOF OPENING FLD=Furnished by Trane U.S.Inc.!Installed by EquipmentSubmitta! Page 17 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 26.0 lb MOTORIZED OUTSIDE AIR DAMPER 1(9\1/4 /D MANUAL OUTSIDE AIR DAMPER \iO ^ v BAROMETRIC RELIEF OVERSIZED MOTOR o aC ���� BELT DRIVE MOTOR 4 �� POWER EXHAUST ��r��a11111o `O�JJ�JJJTHROUGHT THE BASE ELECTRICAL/GAS(FIOPS) p 4 ,//� UNIT MOUNTED CIRCUIT BREAKER(FIOPS) �� UNIT MOUNTED DISCONNECT(FIOPS) POWERED CONVENIENCE OUTLET(FIOPS) HINGED DOORS(FIOPS) Q0 HAIL GUARD SMOKE DETECTOR,SUPPLY/RETURN PACKAGED GAS/ELECTRICAL NOVAR CONTROL CORNER WEIGHT STAINLESS STEEL HEAT EXCHANGER REHEAT ROOF CURB BASIC UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITIY SHIPPING NET O 214.0 lb Q 52.0 lb (E)LENGHT (F)WIDTH 627.0 lb 522.0 lb © 193.0 lb Q 63.0 lb 33" 10" NOTE: 1. All weights are approximate. 2. Weights for options that are not list refer to Installation guide. 3. The actual weight are listed on the unit nameplate. fr%% 4. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 5. The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/_10%of the nameplate weight.6. Verify weight,connection,and all dimension with installer documents before installation. 7. Corner weights are given for information only. 8. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. i. . \. • tel_— ill`� III E oar , PACKAGED GAS/ELECTRICAL RIGGING AND CENTER OF GRAVITY FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 18 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 CLEARANCE FROM TOP OF UNIT 72" CLEARANCE 36" CLEARANCE 48" 1 1 i „......\.......,.......... .._ 1 ,... \ RETURN ,,. DOWNFLOW CLEARANCE 36" HORIZONTAL CLEARANCE 18" CLEARANCE 36" PACKAGED GAS/ELECTRIC CLEARANCE ROOF OPENING I " 7 I UNIT OUTLINE I 37" 44 1/2" I I LL---- -i 40" 68 3/16" PACKAGED GAS/ELECTRIC DOWNFLOW TYPICAL ROOF OPENING T__r�a e--U- -_inc/installed-by Page-1-9 of 48 Others Jaguar Land Rover January 22,2019 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al, A2 Qty: 3 Tag(s): RTU-S-3, RTU-S-5, RTU-S-9 (....n 401114114 111441111 ,,,„%/' ECONOMIZER HOOD BAROMETRIC RELIEF HOOD A NEIN BAROMETRIC RELIEF HOOD 7 3/4" 12" ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 20 of 48 Others Jaguar Land Rover January 22,2019 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: Al Qty: 1 Tag(s): RTU-S-3 C-----) klillt ' ECONOMIZER HOOD ECONOMIZER HOOD 1111 E0 " • 00 00 b 16 3/4" 1 ACCESSORY-ECONOMIZER HOOD FLD-Furnished by Trane U.S.The.f Installed by ., . . _ . . .. .._ Others Jaguar Land Rover January 22,2019 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 (.,.._ ' ,% /' ECONOMIZER HOOD BAROMETRIC RELIEF HOOD BAROMETRIC RELIEF HOOD 4 II - I 4 � � 6 15/16" 9 1/8" ACCESSORY-BAROMETRIC RELIEF DAMPER HOOD FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 22 of 48 Others Jaguar Land Rover January 22,2019 Accessory -3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item: A3 Qty: 1 Tag(s): RTU-S-7 111111 NN.N ECONOMIZER HOOD ECONOMIZER HOOD 4 Ge ee g 4, o--12 1/2" ACCESSORY-ECONOMIZER HOOD FLD-Furnished by Trane U.S.inc.f Installed by equipment Submittal Page 23 of 48 Others Jaguar Land Rover January 22,2019 Tag Data - Packaged Gas/Electric Rooftop Units (Qty: 6) Item Tag(s) Qty Description Model Number B1 RTU-S-1 1 4 Ton Pkgd Gas/Elec Rooftop - GBC048A4ELA B2 RTU-S-2, 2 15 Ton Pkgd Gas/Elec Rooftop GBC180A4EHA RTU-S-6 - B3 RTU-S-4 1 3 Ton Pkgd Gas/Elec Rooftop - GBC036A4ELA B4 RTU-S-8, 2 3 Ton Pkgd Gas/Elec Rooftop - GBC036A4ELA RTU-C-1 Product Data -Packaged Gas/Electric Rooftop Units All Units Gas/Electric Product Efficiency-Gen. B Convertible 460/60/3 Electro-mechanical Wired Thermostat(Fld) Spring Isolation Curb (Fld) Item: B1 Qty: 1 Tag(s): RTU-S-1 4 Ton Gas Heat- Low Manual damper Item: B2 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 15 Ton Gas Heat- High Economizer Dry Bulb with barometric relief Two speed fan standard motor Item: B3 Qty: 1 Tag(s): RTU-S-4 3 Ton Gas Heat- Low Economizer Dry Bulb Barometric Relief(Fld) Item: B4 Qty: 2 Tag(s): RTU-S-8, RTU-C-1 3 Ton Gas Heat- Low Manual OSA Hood FLD=Furnished by Trane U.S Inc./Installed by Equipment Submittal Page 24 of 48 Others Jaguar Land Rover January 22,2019 Performance Data - Packaged Gas/Electric Rooftop Units Tags RTU-S-1 RTU-S-2, RTU-S-4 RTU-S-8, RTU-S-6 RTU-C-1 Airflow Application Downflow Downflow Downflow Downflow Design Airflow(cfm) 1600 6000 1200 1200 Cooling Entering Dry Bulb (F) 82.44 82.64 82.90 82.16 Cooling Entering Wet Bulb (F) 69.39 69.59 69.83 67.00 Ambient Temp (F) 95.00 95.00 95.00 95.00 Gross Total Capacity (MBh) 51.90 190.57 38.88 37.19 Gross Sensible Capacity (MBh) 38.61 141.84 28.99 31.13 Gross Latent Capacity(MBh) 13.29 48.74 9.89 6.06 Net Total Capacity(MBh) 49.64 178.80 36.68 35.00 Net Sensible Capacity(MBh) 36.35 130.07 26.78 28.94 Heating EAT(F) 66.26 65.94 65.55 66.68 Heating LAT(F) 99.44 108.95 109.79 110.92 Heating Temp Rise (F) 33.18 43.01 44.24 44.24 Output Htg Capacity(MBh) 57.60 280.00 57.60 57.60 Output Htg Capacity w/Fan (MBh) 57.60 280.00 57.60 57.60 Design ESP (in H2O) 0.550 1.110 0.500 0.500 Component SP Add (in H2O) 0.000 0.200 0.060 0.060 Indoor RPM (rpm) 877 928 806 806 Indoor Motor Power(kW) 0.00 0.00 0.00 0.00 IPLV @AHRI (IPLV) 14.0 13.2 14.0 14.0 MCA(A) 11.00 35.00 10.50 10.50 MOP (A) 15.00 45.00 15.00 15.00 Compressor 1 RLA(A) 6.20 13.50 5.80 5.80 Compressor 2 RLA(A) 0.00 10.20 0.00 0.00 Condenser Fan FLA (A) 0.70 1.40 0.70 0.70 Evaporator Fan FLA (A) 2.50 4.80 2.50 2.50 Evaporator Face Area (sq ft) 6.44 26.00 6.44 6.44 Evaporator Face Velocity(ft/min) 248 231 186 186 Evaporator Fin Spacing (Per Foot) 192 216 192 192 Evaporator Rows () 2 2 2 2 Min. Unit Operating Weight(Ib) 566.0 0.0 524.0 524.0 Max Unit Operating Weight(Ib) 765.0 0.0 723.0 723.0 Rated capacity (AHRI) (MBh) 48.00 176.00 36.00 36.00 Exhaust fan power(kW) 0.25 0.56 0.25 0.25 Refrig charge (HFC-410A) -ckt 1 (Ib) 4.6 11.4 3.5 3.5 Refrig charge (HFC-410A) -ckt 2 (Ib) - 6.0 - - ASHRAE 90.1 Yes Yes Yes Yes IEER Rating ( ) 14.00 13.20 14.00 14.00 EER @ AHRI Conditions (EER) 12.0 11.0 12.0 12.0 Total Static Pressure (in H2O) 0.550 1.310 0.560 0.560 Length (ft) 6.40 10.26 6.40 6.40 Width (ft) 3.99 7.24 3.99 3.99 Height(ft) 3.55 4.94 3.55 3.55 FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 25 of 48 Others Jaguar Land Rover January 22,2019 Mechanical Specifications -Packaged Gas/Electric Rooftop Units Item: B1 -B4 Qty: 6 Tag(s): RTU-S-1, RTU-S-2, RTU-S-6, RTU-S-4, RTU-S-8, RTU-C-1 15 thru 25 Ton General The units shall be dedicated downflow or horizontal airflow. The operating range shall be between 115°F and 40°F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 3rd Edition. 15 thru 25 Ton Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal,service panels shall have lifting handles and no more than three screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2", 1.0 Ibdensity foil-faced,fire-resistant, permanent, odorless, glass fiber material.The base of the downflow unit shall be insulated with 1/2", 1.0 Ibdensity foil-faced, closed-cell material. The downflow units base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8"high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. 15 thru 25 Ton Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors. All models shall have phase monitors and low and high pressure control as standard. 15 thru 25 Ton Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. 15 thru 25 Ton Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system.This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit,the bi-metal disc in the thermostat switches to the off position,opening the 24 Vac circuit.When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. 15 thru 25 Ton Evaporator and Condenser Coils Microchannel coils will be burst tested by the manufacturer. Internally finned, 5/16" copper tubes mechanically bonded to a configured aluminum plate fin shall be standard for evaporator coils. Microchannel condenser coils shall be standard on all units. Coils shall be leak tested to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. Sloped condensate drain pans are standard. 15 thru 25 Ton Filters Two inch standard filters shall be factory supplied on all units. 15 thru 25 Ton Gas Heating Section The heating section shall have a progressive tubular heat exchanger design.An induced draft combustion blower shall be used to pull the combustion products through the firing tubes.The heater shall use a direct spark ignition (DSI) system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition. After three unsuccessful ignition attempts, the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane (field-installed kit) and also comply with the California requirement for low NOx emissions(Gas/Electric Only). 15 thru 25 Ton High Pressure Control All units include High Pressure Cutout as standard. 15 thru 25 Ton Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. Units with standard motors shall have an adjustable idler-arm assembly for quick-adjustment of fan belts and motor sheaves.All motors shall be FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 26 of 48 Others Jaguar Land Rover January 22,2019 thermally protected. Oversized motors shall be available for high static application.All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 15 thru 25 Ton Low Pressure Control All units include Low Pressure Cutout as standard. 15 thru 25 Ton Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have builtin thermal overload protection. 15 thru 25 Ton Phase Monitor The Phase Monitor is a three-phase line monitor module that protects against phase loss, phase reversal and phase unbalance. It is intended to protect compressors from reverse rotation. It has an operating input voltage range of 190-600 Vac, and LED indicators for ON and FAULT. There are no field adjustments and the module will automatically reset from a fault condition. 15 thru 25 Ton Refrigerant Circuits Each refrigerant circuit shall have independent fixed orifice, service pressure ports, and refrigerant line filter driers factory installed as standard. An area shall be provided for replacement suction line driers. 15 thru 25 Ton Unit Top The top cover shall be double hemmed and gasket sealed to prevent water leakage. 15 thru 25 Ton Multi-Speed Indoor Fan System Multi-speed indoor fan system is designed for use in applications for meeting the minimum requirement of CA Title 24. This system incorporates a multi-speed fan control to change the speed of the fan to 67% of full airflow based off of compressor stages. 15 thru 25 Ton Barometric Relief Designed to be used on downflow units, barometric relief is an unpowered means of relieving excess building pressure. 15 thru 25 Ton Economizer-Downflow The assembly includes fully modulating 0-100%motor and dampers, barometric relief, minimum position setting, preset linkage, wiring harness with plug,fixed dry bulb and spring return actuator. The barometric relief damper shall provide a pressure operated damper that shall be gravity closing and shall prohibit entrance of outside air during the equipment off cycle. Solid state enthalpy and differential enthalpy control shall be field-installed. 3 thru 5 Ton General The units shall be convertible from downflow or horizontal airflow. The operating range shall be between 125.0 F and 40.0 F in cooling as standard from the factory for all units. Cooling performance shall be rated in accordance with ARI testing procedures.All units shall be factory assembled, internally wired,fully charged with R-410A, and 100 percent run tested to check cooling operation, fan and blower rotation and control sequence, before leaving the factory. Wiring internal to the unit shall be colored and numbered for simplified identification. Units shall be UL listed and labeled, classified in accordance to UL 1995/C 22.2, 236-05 5rd Edition. 3 thru 5 Ton Casing Unit casing shall be constructed of zinc coated, heavy gauge, galvanized steel. Exterior surfaces shall be cleaned, phosphatized, and finished with a weather-resistant baked enamel finish. Unit's surface shall be tested 672 hours in a salt spray test in compliance with ASTM B117. Cabinet construction shall allow for all maintenance on one side of the unit. In order to ensure a water and air tight seal, service panels shall have lifting handles and no more than four screws to remove.All exposed vertical panels and top covers in the indoor air section shall be insulated with a 1/2", 1.0 lb density foil-faced, fire-resistant, permanent,dorless, glass fiber material. The base of the downflow unit shall be insulated with 1/2", 1.0 lb density foil-faced, closed-cell material. The downflow unitc,s base pan shall have no penetrations within the perimeter of the curb other than the raised 1 1/8" high supply/return openings to provide an added water integrity precaution, if the condensate drain backs up. The base of the unit shall have provisions for forklift and crane lifting. 3 thru 5 Ton Compressors All units shall have direct-drive, hermetic, scroll type compressors with centrifugal type oil pumps. Motor shall be suction gas-cooled and shall have a voltage utilization range of plus or minus 10 percent of nameplate voltage. Internal overloads shall be provided with the scroll compressors.All models shall have phase monitors and low and high pressure control as standard. FLD=Furnished by Trane-U.S Mc.-<Installed by Equipment-Submittal ______ Page l7oi48 Others Jaguar Land Rover January 22,2019 3 thru 5 Ton Controls Unit shall be completely factory wired with necessary controls and contactor pressure lugs or terminal block for power wiring. Unit shall provide an external location for mounting a fused disconnect device. 3 thru 5 Ton Discharge Line Thermostat A bi-metal element discharge line thermostat is installed as a standard option on the discharge line of each system.This standard option provides extra protection to the compressors against high discharge temperatures in case of loss of charge, extremely high ambient and other conditions which could drive the discharge temperature higher. Discharge line thermostat is wired in series with high pressure control.When the discharge temperature rises above the protection limit,the bi-metal disc in the thermostat switches to the off position,opening the 24 Vac circuit.When the temperature on the discharge line cools down, the bi-metal disc closes the contactor circuit, providing power to the compressor. 3 thru 5 Ton Evaporator and Condenser Coils Microchannel coils will be burst tested by the manufacturer. Microchannel condenser coils shall be standard on all units. Coils shall be leak tested to ensure the pressure integrity. The evaporator coil and condenser coil shall be leak tested to 225 psig and pressure tested to 450 psig. Sloped condensate drain pans are standard. 3 thru 5 Ton Filters Two inch standard filters shall be factory supplied on all units. 3 thru 5 Ton Gas Heating Section The heating section shall have a tubular heat exchanger design.An induced draft combustion blower shall be used to pull the combustion products through the firing tubes.The heater shall use a direct spark ignition(DSI)system. On initial call for heat, the combustion blower shall purge the heat exchanger for 20 seconds before ignition. After three unsuccessful ignition attempts,the entire heating system shall be locked out until manually reset at the thermostat. Units shall be suitable for use with natural gas or propane(field-installed kit) and also comply with the California requirement for low NOx emissions (Gas Heat Only). 3 thru 5 Ton High Pressure Control All units include High Pressure Cutout as standard. 3 thru 5 Ton Indoor Fan Units above shall have belt driven, FC centrifugal fans with adjustable motor sheaves. All motors shall be thermally protected. Oversized motors shall be available for high static application. All indoor fan motors meet the U.S. Energy Policy Act of 1992 (EPACT). 3 thru 5 Ton Low Pressure Control All units include low pressure cutout as standard. 3 thru 5 Ton Outdoor Fans The outdoor fan shall be direct-drive, statically and dynamically balanced, draw-through in the vertical discharge position. The fan motor(s) shall be permanently lubricated and shall have built in thermal overload protection. 3 thru 5 Ton Phase Monitor The Phase Monitor is a three-phase line monitor module that protects against phase loss, phase reversal and phase unbalance. It is intended to protect compressors from reverse rotation. It has an operating input voltage range of 190-600 Vac, and LED indicators for ON and FAULT. There are no field adjustments and the module will automatically reset from a fault condition. 3 thru 5 Ton Refrigerant Circuits Each refrigerant circuit shall have independent thermal expansion valve, service pressure ports, and refrigerant line filter driers factory installed as standard.An area shall be provided for replacement suction line driers. 3 thru 5 Ton Unit Top The top cover shall be double hemmed and gasket sealed to prevent water leakage. Field Installed 3 thru 5 Ton Barometric Relief Designed to be used on downflow units, barometric relief is an unpowered means of relieving excess building pressure. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 28 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -Packaged Gas/Electric Rooftop Units Item: B1, B3, B4 Qty: 4 Tag(s): RTU-S-1, RTU-S-4, RTU-S-8, RTU-C-1 NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ��---<-. � ALL UNITS. 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH ISCON ECTER DOCUMENTSS EFORE ONALL TION UNIT 3. DISCONNECT SWITCH IS NOT STANDARD ON ALL UNITS. DISCONNECT SWITCH SEE NOTE(3) : 1,,i10' THRU THE BASE i0t--'---#%\c,,,,,,_ GAS CONNECTION / HORIZONTAL RETURN KNOCK OUT C' \ W/DUCT OPENING COVER \ CONDENSATE DRAIN CONNECTION GAS CONNECTION HORIZONTAL SUPPLY GAS EXHAUST W/DUCT OPENING COVER FILTER ACCESS �, ) 1,,,,,, -_—____---' o . -. CUSTOMER POWER CONDUIT CONNECTION \\416. MI / � REFRIGERANT GAUGE ACCESS CONDENSATE DRAIN —25 5/8"--. 5 11/16" CONDENSATE DRAIN CONNECTION(1")NPT CONNECTION (1")NPT RETURN UPFLOW I O� \, 107/8" la„ 1 Edi '.•,- �,t, .,, %5 5 1/8"� 6 416" 1 -.-27 3/16" - `� / 5 11/16" CONDENSATE DRAIN DOWNFLOW SUPPLY 12 1/8- o-20 3/4" DIMENSION DRAWING 45 1/2" 74 3/8" _ HORIZONTAL RETURN -163/4"- - - 101/2" HORIZONTAL 9/16" - - 3/16" SUPPLY 1 1 0 7 II 42" !IjI 251/8„ MDi ei 11 vz l'i � `• ® I 1 Ilt�f 16„ 0 IIE' oIIIIIIIIIIIIIIIIIII[s.mIIIIIIIII'a, 5" 9 9/16" , , 4 'I mom _a : 7 3/8" 29 3/4" 73/8" 42 3/16" 7 1/4" L 7 7/8" 7 7/8" 4311/16" - 371/2" - - 24" 4411/16" - 157/8" 7613/16" 4715/16" 4715/16" 20 3/4" 3-5 PACKAGED COOLING DIMENSION DRAWING --LB-=-Furnished bj--Trane U.S.Ma/Installed-by- Equipment Submittal Pepe 29 uf 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-S-1 'ELECTRICAL/GENERAL DATA 'GENERAL 12/4)i6 7/101 HEATING PERFORMANCE Model: GBC048 Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: - MCA: Unit Primary Voltage: 460 MFS: Heating Model: 'Low Unit Secondary Voltage - MCB: Heating Input(BTU): 72000 Unit Hertz: 60 Heating Output(BTU): 57600 Unit Phase: 3 No.Burners: 2 No.Stages 1 EER: 12/14 Gas Inlet Pressure IEER One Speed Fan: - IEER Multi Speed Fan: - Natural Gas(Min/Max): '4.5/14.0 in.wc LP(Min/Max) 11.0/14.0 in.wc Standard Motor Field Installed Oversized Motor Gas Pipe Connection Size: 1/2" MCA: 11.0 MCA: MFS: 15.0 MFS: MCB: 15.0 MCB: 'INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number Number Horsepower: 1.0 Horsepower: Horsepower: Motor Speed(RPM): - Motor Speed(RPM): Motor Speed(RPM): Phase 3 Phase Phase Full Load Amps: 2.0 Full Load Amps: Full Load Amps: Locked Rotor Amps: 15.0 Locked Rotor Amps: Locked Rotor Amps: COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number. 1 Horsepower 5.4 Horsepower: 0.33 Phase: 3 Motor Speed(RPM): Rated Load Amps: 6.2/6.9 Phase: 3 Locked Rotor Amps: 41.0 Full Load Amps: 0.7 Locked Rotor Amps: 2.3 • POWER EXHAUST ACCESSORY (31 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type: R-410A Phase: Type: Throwaway Horsepower: Furnished: Yes Factory Charge: Motor Speed(RPM): Number 4 Circuit#1 4.6 lb Full Load Amps: Recommended 16"x16"x2" Circuit#2 Locked Rotor Amps: NOTES: 1. Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value does not include Heater. 5. Value include Standard Motor. 6. Value include Oversized Motor 7. EER is rated at AHRI conditions and in accordance with DOE test procedures. 8. For Compressor Motors and Condenser Fan Motors:Amp draw for each motor;multiply value by number of motors to determine total amps. • 9. HP for each compressor. • 10. Integrated Energy Efficiency Ratio(IEER)is rated in accordance with AHRI standard 210/240 or 360. FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 30 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions -Packaged Gas/Electric Rooftop Units Item: 82 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 NOTES: 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. 2.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WT \ INSTALLER DOCUMENTS BEFORE INSTALLATION ‘plo5dP CONDENSATE DRAIN p ?� CONNECTION(1")NPT -., 0 GAS CONNECTION •`i��1 / REFRIGERANT GAUGE ACCESS GAS CONNECTION (TBU GAS ONLY) •./ CUSTOMER POWER CONDUIT CONNECTION(ALTERNATE) DISCONNECT SWITCH ACCESS PACKAGED GAS/ELEC DOWNFLOW DIMENSION DRAWING -=,------123 1/8" 14 3/8" i- - o--,=--14 3/8" 66 7/8"I"--,..- o— -=—,--17 15/16" --� 1 1 - / 64 9/16., 72" 64 13/16' 73 1/2' 68 9/16"i /' _ 86 15/16" 6 13/16" G - ° -_ y 1415/16" 7" o-- -:=-19 5/16"o-42 3/8" 123 1/8" PLAN VIEW OF UNIT DIMENSION DRAWING - 1 ■, IA 0I 59 5/16" 58 5/8" 3913/16" 1 22 7/16' 50 7/8" - 4 1/2" - 1 - 821/4" - 715/16" - - 1231/8" 13" - - RIGHT VIEW OF UNIT FRONT VIEW OF UNIT DIMENSION DRAWING DIMENSION DRAWING FLL2_=Furnished_by Tram= Mc J abyEquipment Submittal Others PAge 37 of ger Jaguar Land Rover January 22,2019 Unit Dimensions -Packaged Gas/Electric Rooftop Units Item: B2 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 'ELECTRICAL/GENERAL DATA 'GENERAL(211416171101 HEATING PERFORMANCE Model: GBC180 Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: - MCA: Heating Model: 'High Unit Primary Voltage: 460 MFS: Heating Input(BTU): 350000/245000 Unit Secondary Voltage - MCB: Unit Ph60 Heating Output(BTU): 280000/196000 Unit s:Phase: 3 No.Burners: 8 No.Stages 2 EER: 11/- 'Gas Inlet Pressure IEER One Speed Fan: - Natural Gas(Min/Max): '4.5/14.0 in.we IEER Multi Speed Fan: 12.8 LP(Min/Max) 11.0/14.0 in.we Standard Motor Field Installed Oversized Motor Gas Pipe Connection Size: 3/4" MCA: 35.0 MCA: MFS: 45.0 MFS: MCB: 45.0 MCB: 'INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number. '1 Number: Number Horsepower: 3.0 Horsepower: Horsepower: Motor Speed(RPM): 1750 Motor Speed(RPM): Motor Speed(RPM): Phase 3 Phase Phase Full Load Amps: 4.8 Full Load Amps: Full Load Amps: Locked Rotor Amps: 40.5 Locked Rotor Amps: Locked Rotor Amps: COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '2 Number: '2 Horsepower 7.0/6.0 Horsepower: 1.0 Phase: 3 Motor Speed(RPM): 1100 Rated Load Amps: 13.5/10.2 Phase: 3 Locked Rotor Amps: 100.0/62.0 Full Load Amps: 1.4 Locked Rotor Amps: 5.92 • POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type: R-410A Phase: Type: Throwaway Horsepower Furnished: Yes Factory Charge: Motor Speed(RPM): Number 8 Circuit#1 7.6 lb Full Load Amps: Recommended 20"x25"x2" Circuit#2 7.0 lb Locked Rotor Amps: NOTES: 1. Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value does not include Heater. 5. Value include Standard Motor. 6. Value include Oversized Motor 7. EER is rated at AHRI conditions and in accordance with DOE test procedures. 8. For Compressor Motors and Condenser Fan Motors:Amp draw for each motor;multiply value by number of motors to determine total amps. 9. HP for each compressor. 10. Integrated Energy Efficiency Ratio(IEER)is rated in accordance with AHRI standard 210/240 or 360. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 32 of 48 Others Jaguar Land Rover January 22,2019 Unit Dimensions - Packaged Gas/Electric Rooftop Units Item: B3, B4 Qty: 3 Tag(s): RTU-S-4, RTU-S-8, RTU-C-1 'ELECTRICAL/GENERAL DATA GENERAL l211aXs>171(70) HEATING PERFORMANCE Model: GBC036 Oversized Motor HEATING-GENERAL DATA Unit Operating Voltage: - MCA: Unit Primary Voltage: 460 MFS: Heating Model: 'Low Unit Secondary Voltage _ MCB: Heating Input(BTU): 72000 Unit Hertz: 60 Heating Output(BTU): 57600 Unit Phase: 3 No.Burners: 2 No.Stages 1 EER: 12/14 'Gas Inlet Pressure IEER One Speed Fan: IEER Multi Speed Fan: _ Natural Gas(Min/Max): '4.5/14.0 in.wc LP(Min/Max) 11.0/14.0 in.wc Standard Motor Field Installed Oversized Motor Gas Pipe Connection Size: 1/2" MCA: 10.5 MCA: MFS: 15.0 MFS: MCB: 15.0 MCB: 'INDOOR MOTOR Standard Motor Oversized Motor Field Installed Oversized Motor Number '1 Number: Number: Horsepower: 1.0 Horsepower: Horsepower: Motor Speed(RPM): - Motor Speed(RPM): Motor Speed(RPM): Phase 3 Phase Phase Full Load Amps: 2.0 Full Load Amps: Full Load Amps: Locked Rotor Amps: 15.0 Locked Rotor Amps: Locked Rotor Amps: COMPRESSOR Circuit 1/2 OUTDOOR MOTOR Number: '1 Number: '1 Horsepower. 4.10 Horsepower: 0.33 Phase: 3 Motor Speed(RPM): - Rated Load Amps: 5.8/6.3 Phase: 3 Locked Rotor Amps: 38.0 Full Load Amps: 0.7 Locked Rotor Amps: 2.3 POWER EXHAUST ACCESSORY 131 FILTERS REFRIGERANT (2) (Field Installed Power Exhaust) Type: R-410A Phase: Type: Throwaway Horsepower: Furnished: Yes Factory Charge: Motor Speed(RPM): Number 4 Circuit#1 3.5 lb Full Load Amps: Recommended 16"x16"x2" Circuit#2 Locked Rotor Amps: NOTES: 1. Maximum(HACR)Circuit Breaker sizing is for installations in the United States only. 2. Refrigerant charge is an approximate value.For a more precise value,see unit nameplate and service instructions. 3. Value does not include Power Exhaust Accessory. 4. Value does not include Heater. 5. Value include Standard Motor. 6. Value include Oversized Motor 7. EER is rated at AHRI conditions and in accordance with DOE test procedures. 8. For Compressor Motors and Condenser Fan Motors:Amp draw for each motor;multiply value by number of motors to determine total amps. 9. HP for each compressor. 10. Integrated Energy Efficiency Ratio(IEER)is rated in accordance with AHRI standard 210/240 or 360. FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 33 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram -Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-S-1 Base Unit and Corner Weights only Base unit weights Corner Weights Center of Gravity SHIPPING NET AO 0 ® O E F 616.0 lb 566.0 lb 110.0 lb 119.0 lb 175.0 lb 162.0 lb 40" 29" 1.All weights are approximate. `._ 2.The actual weight are listed on the unit nameplate. � , 73.Refer to unit nameplate and installation guide for weights before scheduling transportation / and installation of unit. 4.The weight shown represents the typical unit operating weight for the configuration tO selected.Estimated at,-/_10 %of the nameplate weight.. 5.Verify weight,connection,and all dimension with installer documents before installation. 6.Corner weights are given for information only. 7.Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. Installed Options Net Weight Data �� Accessory Weight Economizer,Manual and Motorized Outside Air Damper 16" Barometric Relief Power Exhaust Roof Curb • Oversized Motor PACKAGED COOLING PLAN VIEW Disconnect Flail Guard RIGGING DRAWING Through the Base • Through the Gas 1.Weights for options are approximate. 2.Weights for options that are not list refer to Installation guide. A O - .0.}9_____i , .• ..„:„ . • 1 / \ B \ N�°? J.��Jllllll _IL o 0 PACKAGED COOLING PLAN VIEW CENTER OF GRAVITY DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 34 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram -Packaged Gas/Electric Rooftop Units Item: B1, B3, B4 Qty: 4 Tag(s): RTU-S-1, RTU-S-4, RTU-S-8, RTU-C-1 NOTES: BACK OF UNIT 1.THRU-THE-BASE ELECTRICAL IS NOT STANDARD ON ALL UNITS. CLEARANCE 60" HORIZONTAL RETURN O'<I ,ill MX AA ff\ --,..,. ... w 1 >• CLEARANCE 68" '` CLEARANCE 48" - HORIZONTAL SUPPLY CLEARANCE 36" FRONT OF UNIT PACKAGED GAS/ELECTRIC PLAN VIEW CLEARANCE DRAWING AO"' 3315/16" `, 42"/ \ / PACKAGED GAS/ELECTRIC PLAN VIEW DOWNFLOW CLEARANCE DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 35 of 45 Others Jaguar Land Rover January 22,2019 Weight,Clearance& Rigging Diagram -Packaged Gas/Electric Rooftop Units Item: B2 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 CLEARANCE 68" CLEARANCE 36" CLEARANCE FROM THE TOP OF UNIT 72" e 41100. CLEARANCE 60" 0 0 CLEARANCE 48" DOWNFLOW-PACKAGED COOLING WITH ELECTRIC CLEARANCE UNIT OUTLINE \ ROOF OPENING \ \ 761/2" 81" � \ � DOWNFLOW-PACKAGED COOLING WITH ELECTRIC ROOF OPENING CLEARANCE FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 36 of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: B2 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 INSTALLED ACCESSORIES NET WEIGHT DATA ACCESSORY WEIGHTS ECONOMIZER 91.0 lb MOTORIZED OUTSIDE AIR DAMPER i ���///�J n MANUAL OUTSIDE AIR DAMPER OVERSIZED MOTOR 0'"\s--.N � MULTI-SPEED WITH DRIVE 65.0 lb I/////G�A���111 THROUGH THE BASE ELECTRICAL Wt:NB BAROMETRIC 40.0 lb ROOF CURB 0 §,91' POWER EXHAUST "��"����%�1��`� HAIL GUARD LP GAS CONVERSION ( STATIC DRIVE ` DISCONNECT B O CORNER WEIGHT BASE UNIT WEIGHTS CORNER WEIGHTS CENTER OF GRAVITY SHIPPING NET OA 632.0 lb © 396.0 lb (E)LENGTH (F)WIDTH 2310.0 lb 1990.0 lb OB 505.0 lb OD 457.0 lb 55 5/T '36 7/8" NOTE: 1. All weights are approximate. 2. The actual weight are listed on the unit nameplate. 3. Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. 4. The weight shown represents the typical unit operating weight for the configuration selected. Estimated at+/-10 %of the nameplate weight.. 5. Verify weight,connection,and all dimension with installer documents before installation. 6. Corner weights are given for information only. 7. Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. 8.Weights for options are approximate. 9.Weights for options that are not list refer to Installation guide. 41. I ''.....-r„------------- , ,-,. ,, „„ ...1 „, ►�I ,,,e .. F in RIGGING AND CENTER OF GRAVITY _ FW=Furnished by Trane LLS Inc.l Installed by Page 3-7-of 48 Others Jaguar Land Rover January 22,2019 Weight, Clearance& Rigging Diagram - Packaged Gas/Electric Rooftop Units Item: B3, B4 Qty: 3 Tag(s): RTU-S-4, RTU-S-8, RTU-C-1 Base Unit and Corner Weights only Base unit weights Corner Weights Center of Gravity SHIPPING NET O O © © E F 574.0 lb 524.0 lb 95.0 lb 111.0 lb 172.0 lb 146.0 lb 42" 29" 1.All weights are approximate. 2.The actual weight are listed on the unit nameplate. 3.Refer to unit nameplate and installation guide for weights before scheduling transportation and installation of unit. ®®®fif 4.The weight shown represents the typical unit operating weight for the configuration selected.Estimated at+/_10 %of the nameplate weight.. 5.Verify weight,connection,and all dimension with installer documents before installation. 6.Comer weights are given for information only. 7.Net/Shipping weight of optional accessories should be added to unit weight when ordering factory or field installed accessories. Installed Options Net Weight Data Accessory Weight �� Economizer,Manual and Motorized Outside Air Damper 26.0 lb Barometric Relief 7.0 lb Power Exhaust • Roof Curb Oversized Motor PACKAGED COOLING PLAN VIEW Disconnect Hail Guard RIGGING DRAWING Through the Base Through the Gas 1.Weights for options are approximate. 2.Weights for options that are not list refer to Installation guide. A • • • • • �r %��\ a�11111111 ��.ii��,,�°,.,,, ��llllll . • • 0 O PACKAGED COOLING PLAN VIEW CENTER OF GRAVITY DRAW NG FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 38 of 48 Others Jaguar Land Rover January 22,2019 Accessory -Packaged Gas/Electric Rooftop Units Item: B1 - B4 Qty: 6 Tag(s): RTU-S-1, RTU-S-2, RTU-S-6, RTU-S-4, RTU-S-8, RTU-C-1 a— 6" o - 1 3/8" ,.. 7 (II'45/8" - 3 5/16" - O 3 5/16' I li LI~' flfl ' UP O LII I TCONT802-(31-112C) ACCESSORY-THERMOSTAT FLD=Furnished by T-ane-Lk&Inc IInstailed by _ __ Page 39 of48 Others Jaguar Land Rover January 22,2019 Accessory - Packaged Gas/Electric Rooftop Units Item: B1 Qty: 1 Tag(s): RTU-S-1 NOTES 1.VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION ,( \ ' c el HORIZONTAL RETURN t i W/DUCT OPENING COVER ,; CONDENSATE DRAIN CONNECTION MANUAL DAMPER HOOD HORIZONTAL SUPPLY W/DUCT OPENING COVER MANUAL DAMPER DIMENSION DRAWING MANUAL DAMPER HOOD FAN GRILLE FILTER ACCESS 1 1 Mlirl VIIIMANUAL DAMPER HOOD 'El 16111111.111..111 — 0 1111' 4 0MMINILMI 111111111■1 10 13 : 9 3/4.. 251/4" - 121/16" - BACK VIEW OF UNIT LEFT VIEW OF UNIT DIMENSION DRAWING DIMENSION DRAWING FLD=Furnished by Trane U.S. Inc./Installed by Equipment Submittal Page 40 of 48 Others Jaguar Land Rover January 22,2019 Accessory -Packaged Gas/Electric Rooftop Units Item: B2 Qty: 2 Tag(s): RTU-S-2, RTU-S-6 NOTES: 1 VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION I 0 it il'I` ECONOMIZER HOOD N____BAROMETRIC RELIEF PLAN VIEW OF UNIT DIMENSION DRAWING ECONOMIZER WITH BAROMETRIC RELIEF DIMENSION DRAWING ECONOMIZER HOOD FAN BAROMETRIC RELIEF A IIL1 LIiii," BAROMETRIC RELIEF 58 5/8' __Al IIS Nimm I�[�7�III I E.1 8 7/8" I 9 3/8" I �I III 1 1 135/8' -. .-- ---- -- 20 3/16" -• - - 19 3/16" 6 ► 7 3/4" - - 68 3/8" - - 123 1/8 - 8615/16" .-- BACK BACK VIEW OF UNIT LEFT VIEW OF UNIT DIMENSION DRAWING DIMENSION DRAWING FL©=Furnished by Trane U.S.Inc./Installed by - Equipment Submittal Page 41 of 48 Others Jaguar Land Rover January 22,2019 Accessory -Packaged Gas/Electric Rooftop Units Item: B3, B4 Qty: 3 Tag(s): RTU-S-4, RTU-S-8, RTU-C-1 NOTES 1 VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION FAN GRILLE • HORIZONTAL RETURN W/DUCT OPENING COVER HORIZONTAL SUPPLY W/DUCT OPENING COVER -j L !� COIL BAROMETRIC RELIEF HOOD 410 BAROMETRIC RELIEF HOOD DIMENSION DRAWING HORIZONTAL RETURN FAN GRILLE W/DUCT OPENING COVER FILTER ACCESS BAROMETRIC RELIEF HOOD BAROMETRIC 71111111 RELIEF COIL HOODLEI 1�1 8, o I-I I=mac SdICI - I-41/8" 7 13/16" - - HORIZONTAL SUPPLY - 13 7/16" W/DUCT OPENING COVER BACK VIEW OF UNIT RIGHT VIEW OF UNIT DIMENSION DRAWING DIMENSION DRAWING FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 42 of 48 Others Jaguar Land Rover January 22,2019 Accessory - Packaged Gas/Electric Rooftop Units Item: B3, B4 Qty: 3 Tag(s): RTU-S-4, RTU-S-8, RTU-C-1 NOTES 1 VERIFY WEIGHT,CONNECTION,AND ALL DIMENSION WITH INSTALLER DOCUMENTS BEFORE INSTALLATION FAN GRILLE < -io COIL HORIZONTAL SUPPLY41 W/DUCT OPENING COVER `OD� CONDENSATE DRAIN CONNECTION ECONOMIZER HOOD HORIZONTAL RETURN W/DUCT OPENING COVER ECONOMIZER HOOD DIMENSION DRAWING ECONOMIZER HOOD FAN GRILLE HORIZONTAL RETURN W/DUCT OPENING COVER FILTER ACCESS HORIZONTAL SUPPLY 11 W/DUCT OPENING COVER MOTORIZED HOOD 1="=I BACK VIEW OF UNIT RIGHT VIEW OF UNIT DIMENSION DRAWING DIMENSION DRAWING FLD•Famished by Irene U.S.inc.-1-installed by Equipment Submittal Page 43 of 48 Others Jaguar Land Rover January 22,2019 Field Installed Options - Part/Order Number Summary This is a report to help you locate field installed options that arrive at the jobsite. This report provides part or order numbers for each field installed option, and references it to a specific product tag. It is NOT intended as a bill of material for the job. Product Family-3-10 Ton R-410A PKGD Unitary Gas/Electric Rooftop Item Tag(s) Qty Description Model Number Al RTU-S-3 1 10 Ton R410A PKGD Unitary YSC120H4ELA Gas/Electric A2 RTU-S-5, RTU-S-9 2 6 Ton R410A PKGD Unitary YSC072H4ELA Gas/Electric A3 RTU-S-7 1 5 Ton R410A PKGD Unitary YSC060G4ELB Gas/Electric Field Installed Option Description Part/Ordering Number 3H/2C Touchscreen, programmable, remote temperature, remote humidity BAYSTAT152A Product Family - Packaged Gas/Electric Rooftop Units Item Tag(s) Qty Description Model Number B1 RTU-S-1 _1 4 Ton Pkgd Gas/Elec Rooftop - GBC048A4ELA B2 RTU-S-2, RTU-S-6 2 15 Ton Pkgd Gas/Elec Rooftop - GBC180A4EHA Field Installed Option Description _Part/Ordering Number 3H/2C 7-Day Programmable Touchscreen TCONT802AS32DA Item Tag(s) Qty Description Model Number B3 RTU-S-4 1 3 Ton Pkgd Gas/Elec Rooftop - GBC036A4ELA B4 RTU-S-8, RTU-C-1 2 3 Ton Pkgd Gas/Elec Rooftop - GBC036A4ELA Field Installed Option Description Part/Ordering Number Wall Mounted CO2 Sensor kit BAYCO2K300A 3H/2C 7-Day Programmable Touchscreen TCONT802AS32DA Barometric Relief BAYBARO320A FLD=Furnished by Trane U.S.Inc./Installed by Equipment Submittal Page 44 of 48 Others STRUCTURALLY CALCULATED VIBRATION ISOLATION CURB CBC COMPLIENT WITH IBC 2012, CBC 2013, ASCE 7-10 SELECT BASE CURB APPROXIMATE • – MIN 16 GA. GALVANIZED STEEL. I PRODUCT i HEIGHT SHIPPING WEIGHT • – SHIPPED FULLY WELDED AND ASSEMBLED. 7.75 \ / .13 6038-1C08A-CBC 8" 262 LBS. • - FULL PERIMETER BASE CURB, WOOD NAILER, ISO RAIL, r FLASHING AND WATER AND AIR BARRIER. I L J 0 1 6038-1c11A-CBC = • - SPRING ISOLATION WITH 2" STATIC DEFLECTION AND a 6038–IC14A–CBC 14" 287 LBS. EARTHQUAKE RESTRAINTS (OSHPD PRE–APPROVED). 16.58 o 6038–IC18A–CBC 18" 302 LBS. • – WEATHER TIGHT ACCESS DOORS AT EACH ISOLATOR LOCATION. NOTE: FINISH HEIGHT IS 12.5" TALLER THAN BASE CURB HEIGHT. 401 SELECT ENGINEER OR RECORD SHALL PROVIDE �� ' •>S T C-... ...,/- SELECT ��/r SUPPORT STRUCTURE AND VERIFY THE 7 l CONSToRUCTION y(. 1; g> P `�N.� ADEQUACY OF THE STRUCTURE FOR A=STANDARD WELDED CONSTRUCTION. LOADS IMPOSED ON THEM BY UNIT AS ��.r• • WELL AS ALL OTHER LOADS, FOR ALL 3/5 �� E=STANDARD WELDED CONSTRUCTION SHEET METAL FASTENERS, USE HILTI g. © ' �i ./ �•\ KWIK PRO SELF–DRILLING SCREW. 1 EXTERNALLY INSULATED. INSTALL PER ICC ESR-2196 � ► i/ A/C UNIT— ASKETING 5625 r� -.7 �� ....1 4. itil0 4 lo. • • (8) #12 SELF TAPPING SCREWS I I `. I I r ` (4) #12 SELF TAPPING SCREWS I 10 GA ISO RAIL � L .`. ] .\ (8) 6907–SHD L J 7.5" DEEP WITH / 14 GAUGE HOLD DOWN 1" FLANGES 4 � GASKETING (6) JQA ISOLATOR / CURB PLAN FLASHIN =I. OPA-0070 OI 61./5 STRUCTURAL REVIEW BY: s 9�1.0) • b Sr WOOD NAILS- 3 •43�5 Z U) JOHN A.MARTIN AND ASSOCIATES yolL - 50 Sou GraEngind APROVIDE FlRST CONNECTION TO Imo�—//' rs 650 SouM Grand Ave.,4th Floor STRUCTURE AT MAX 5" FROM IJ– Los Angeles,California 90015 3 EDGE OF THE CURB. Q V) Phone(213)483 6490 SEE DETAILS BELOW. 5 fp Fax(213)483 3084 P L CO Job No.:13001 0`�'� ATTACHMENT TO STRUCTURAL 325 10 GA X 10.5" DEEP I ATTACHMENT TO WOOD CONCRETE ' 3000 PSI ATTACHMENT TO /� CHANNEL WITH 1" FLANGES NORMAL WEIGHT TR "A UNDER EACH ISOLATOR STRUCTURAL s OUTSIDE CURB /'/��•,•,, CONCRETE PROVIDE ADDITIONAL WELDS CODE NOTE : AT EACH END OF 10 GA ,, } } THE CURB HAS BEEN CHANNEL TO CURB FLANGES. Jj 6" MIN DESIGNED FOR SDS=1.5G A. AS AGREED WITH THE 4" MIN I BY OTHERS CLIENT TO COVER MOST OF (6) 5/8" HILTI KWIK BOLT TZ. THE CA AREA FOR THE (16) 3/8"x4" LAG SCREWS. 1/2 EACH LONG SIDE. HIGH SEISMIC REGIONS WITH SDS>1.5G FURTHER 1/2 EACH LONG SIDE. (4) 5/8" HILTI KWIK BOLT TZ. 1/8" FILLET WELD.ANALYS MODIFICATIONAND AND ARE (8) 3/8"x4" LAG SCREWS. 1/2 EACH SHORT SIDE. 2" LONG ® 24" ON CENTER A MODIFICA TN THE CURB 1/2 EACH SHORT SIDE. CENTER ON CURB BOTTOM, PROVIDE MIN 2 CONNECTIONS PRIOR TO INSTALLATION. CENTER ON CURB BOTTOM, (ICC–ES ESR-1917) EACH SIDE TRANS PRECEDENT 3-5 TON RTU-S-7 (((canFab CANNON FABRICATION INC 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PART NO: SEE ABOVE PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfabecanfab.com DRAWING NO: DATE: APPROVED BY: DATE: / / STRUCTURALLY CALCULATED ROOF CURB CBC COMPLIENT WITH IBC 2012, CBC 2013 SELECT BASE CURB APPROXIMATE • - ROOF CURB IS MIN 16 GA. GALVANIZED STEEL. + PRODUCT HEIGHT SHIPPING WEIGHT • - SHIPPED FULLY WELDED AND ASSEMBLED. 7.75 \ / • - FULL PERIMETER BASE CURB, WOOD NAILER, ISO RAIL, El } r 6042-IC08A CBC 8 FLASHING AND WATER AND AIR BARRIER. I L ❑ 16042-IC11A-CBC 1MM 360 LBS • - SPRING ISOLATION WITH 2" STATIC DEFLECTION AND 17.125 ❑ 6042-IC14A-CBC 14" 375 LBS. EARTHQUAKE RESTRAINTS (OSHPD PRE-APPROVED). ❑ 6042-IC18A-CBC 18" 395 LBS. • - WEATHER TIGHT ACCESS DOORS AT EACH ISOLATOR LOCATION. • - ALL WELDING CONSTRUCTION CERTIFIED TO ANSI/AWS D1.3 NOTE: FINISH HEIGHT IS 12.5" TALLER STRUCTURAL WELDING CODE - SHEET METAL THAN BASE CURB HEIGHT.SELECT NOTE ' 401 T 5' r Yp CONSTRUCTION ENGINEER OF RECORD SHALL ' PROVIDE SUPPORT STRUCTURE AND i� ❑ A=STANDARD WELDED CONSTRUCTION. VERIFY THE ADEQUACY OF THE 25 / E ��' .�\ ] STRUCTURE FOR LOADS IMPOSED FJ �� E=STANDARD WELDED CONSTRUCTION ON THEM BY UNIT AS WELL AS ALL g' © � �! ��� ��� ❑ OTHERLOADS INCLUDING DRIFTED ,� �. EXTERNALLY INSULATED. SNOW LOADS.ASFOR ALL SHEET 1g' 3 / METALROLF—DRERS USE HILTIW. KWIK 4 > ` / PRO SELF—DRILLING SCREW. Iiii ' / r`\\ J INSTALL PER ICC-ESR-2196 r�44100.. L PITCHED A/C UNIT-1 GASKETING _'4 ` \�� (8) #14 SELF TAPPING SCREWS I I 01111° r �. (4) #14 SELF TAPPING SCREWS I I '� 10 GA ISO RAIL 7.5" DEEP WITH /� , 5 CURB PLAN 1" FLANGES (10) 6907-SHE 14 GAUGE HOLD DOWN HIN (10)-JQA 0070ISOLATOR ��6 / 8 STRUCTURAL REVIEW BY: FLASHIN _ N JOHN A.MARTIN AND ASSOCIATES WOOD NAILS 10GA CHANNEL UNDER EACH \ "OVIDE FIRST CONNECTION TO Z +- Structural Engineers �/ STRUCTURE AT MAX 6" FROM �/ 950SouthGandAve.,4thFloor ISOLATOR OUTSIDE CURB. EDGE OF THE CURB. LL U Los Angeles,Calrrfomia 90015 1"x10.5"x1" PROVIDE ADDITIONALSEE DETAILS BELOW. Q N Phone(213)483 6490 WELDS AT EACH END OF 10 GA V) (213)483 3084 5 "SI j 5 CHANNEL TO CURB FLANGES ATTACHMENT TO STRUCTURAL ATTACHMENT TO Job 13001 9 to r CONCRETE SLAB STRUCTURAL STEEL oel 3000 PSI o NORMAL WEIGHT i' CODE NOTE : IIII STRUCTURAL 2 A THE CURB HAS BEEN DESIGNED CONCRETE 0 1 ° FOR SDS=1.5G, 1=1.5, AND �_, NON—SPECIAL WIND REGION AS AGREED WITH THE CLIENT TO .�! STEEL BEAM �� COVER MOST OF THE CA AREA 4" MIN 6 MIN BY OTHERS 325 , FOR THE HIGH SEISMIC REGIONS I WITH SDS>1.5G OR SPECIAL WIND REGIONS, FURTHER (10) 5/8" HILTI KWIK BOLT TZ, 1/8" FILLET WELD. -r,s ANALYSIS AND MODIFICATIONS HALF EACH LONG SIDE. 2" LONG, 24" ON CENTER TO THE CURB ARE REQUIRED PRIOR TO CONSTRUCTION. ( ) /g 5 8" HILTI KWIK BOLT TZ, MIN (2) CONNECTIONS HALF EACH SHORT SIDE, ALONG EACH SIDE CENTER ON CURB BOTTOM (ICC-ES ESR-1917) SCALE: NTS TRANE PRECEDENT 6-10 TONS RTU-S-5, (((CanFab RTU-S-9 CANNON FABRICATION INC 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PART NO: SEE ABOVE PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com canfabOcanfab.com DRAWING NO: DATE: APPROVED BY: DATE: / / FOR: TRANE GBC 036-060 (((CanFab FABRICATION INC 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PHONE:(951)278-1830 FAX:(951)278-8444 www.canfab.com can fabOcan fab.com PART NO: SEE BELOW VIBRATION ISOLATION CURB FEATURES SELECT • SHIPPED FULLY WELDED AND ASSEMBLED. PRODUCT • FULL PERIMETER BASE CURB, WOOD NAILER, RAIL, FLASHING AND WATER AND AIR BARRIER. • SPRING ISOLATION WITH 2" STATIC DEFLECTION BASE APPROXIMATE AND EARTHQUAKE RESTRAINTS (OSHPD APPROVED). CANFAB PART# CURB HEIGHT SHIPPING WEIGHT • WEATHER TIGHT ACCESS DOORS AT EACH ISOLATOR ❑ 1803046—IC14A 14" 335 LOCATION FOR ADJUSTMENT. • OTHER AVAILABLE OPTIONS INCLUDE SINGLE PITCH AND COMPOUND PITCH. SELECT NOTE: FINISH HEIGHT IS 12.5" TALLER THAN THE BASE CURB HEIGHT. CONSTRUCTION 0 A=STANDARD WELDED CONSTRUCTION (SHOWN ABOVE). ❑ E=STANDARD WELDED CONSTRUCTION 1 �5 EXTERNALLY INSULATED. 5 ElC=CUSTOM CONTRUCTION. 32.18 21 �P. SEL PITCHED" _ . ` "ITCH 1Ii% ORIENTATIO r .-.`•u 14 4 435 0'W IE - " HED0 �� J�2 / •1•••"•e/ 00 Unit ,� RTU-S-1, �o RTU-S-4, RTU-S-8, Perimeter Frame RTU-C-1 r!1 Perimeter Flashing 2" Static Deflection Zr • Isolator & Earthquake Bulb Seal Wood Nailer Curb DOC: 02-02 PROJECT: DATE: ENGINEER: DISTRIBUTOR: DRAWING NUMBER: 1803046MI.DWG JM 04.20.17 STRUCTURALLY CALCULATED VIBRATION ISOLATION CURB CBC COMPLIENT WITH IBC 2012 CBC 2013 SELECT BASE CURB APPROXIMATE • - ROOF CURB IS MIN 16 GA. GALVANIZED STEEL. PRODUCT • HEIGHT SHIPPING WEIGHT • - SHIPPED FULLY WELDED AND ASSEMBLED. + • - FULL PERIMETER BASE CURB, WOOD NAILER, ISO RAIL, 7.75 13 6010 IC08A CBC 8 610 LBS FLASHING AND WATER AND AIR BARRIER. 0 6010-1C11A-CBCIIIIIIMI 640 LBS. • - SPRING ISOLATION WITH 2" STATIC DEFLECTION AND 20.2375 o 6010-IC14A-CBC 670 LBS. EARTHQUAKE RESTRAINTS (OSHPD PRE-APPROVED). 0 6010-IC18A-CBC 18" 710 LBS. • - WEATHER TIGHT ACCESS DOORS AT EACH ISOLATOR LOCATION. r NOTE: FINISH HEIGHT IS 12.5" TALLER 4 1•�5 L THAN BASE CURB HEIGHT. 505 lYp SELECT ENGINEER OR RECORD SHALL PROVIDE • CONSTRUCTION SUPPORT STRUCTURE AND VERIFY THE 2 . 5 2/ 69.5 o A=STANDARD WELDED CONSTRUCTION. ADEQUACY OF THE STRUCTURE FOR L J LOADS IMPOSED ON THEM BY UNIT AS 25.25 E=STANDARD WELDED CONSTRUCTION WEEE AS ALL AHTR ESFOR ALL `C>,. N„,..• . j SHEET METAL FASTENERS, USE HILTI EXTERNALLY INSULATED. KWIK PRO SELF-DRILLING SCREW. b,//''F" .` ',!� ` . �' ,,\ INSTALL PER ICC ESR-2196 � ` / / r PITCHED A/C UNIT-1 GASKETING 40,...... � �, ` ' (8) #14 SELF TAPPING SCREWS I I kg., I* \�L0. (5) #14 SELF TAPPING SCREWS I 10 GA ISO RAIL �.. , ' r 7.5" DEEP WITH ���.\ � , L J 1" FLANGES �. (12) 6909-SHD _ ....<> 10• 10 GAUGE HOLD DOWN (16) JQA ISOLATORS/! �� r FLASH IN =�= OPA-0070 ,--- L • 1 WOOD NAILE' 10GA CHANNEL UNDER EACH >> CURB PLAN ISOLATOR OUTSIDE CURB. \ 1.85 1"x10.5"x1" PROVIDE ADDITIONAL \ ..1 STRUCTURAL REVIEW BY: gOil WELDS AT EACH END OF 10 GA yyy 9 to CHANNEL TO CURB FLANGES PROVIDE FIRST CONNECTION TO Z N _ 0.) JOHN A.MARTIN AND ASSOCIATES 01 STRUCTURE AT MAX 6" FROM JOHNCD Structural Engineers 0 oEDGE OF THE CURB. •V 950 South Grand Ave.,4th Floor 0 0 Los Angeles,California 90015 o SEE DETAILS BELOW. ori ATTACHMENT TO STRUCTURAL ATTACHMENT TO Q 36490 Cl) Fax(213)483 Phone(213)48213)48084 2 � � CONCRETE SLAB STRUCTURAL STEEL, (6 Job No.:13001 3000 PSI 0 ODE NOTE: NORMAL WEIGHT �1 THE CURB HAS BEEN DESIGNED STRUCTURAL FOR SDS=1.5G 1=1.0 AND NON-SPECIAL pi CONCRETE G , WIND REGION AS AGREED WITH THE CLIENT TO COVER MOST OF THE CA E�1 } STEEL BEAM AREA. FOR HIGH SEISMIC REGIONS 4" MIN 6" MIN ABY OTHERS �� WITH SDS>1.5G I>1.0 OR SPECIAL WIND i S REGIONS, FURTHER ANALYSIS AND MODIFICATIONS TO THE CURB ARE (10) 5/8" HILTI KWIK BOLT TZ, 1/8" FILLET WELD. REQUIRED PRIOR TO FABRICATION. HALF EACH LONG SIDE. 2" LONG, 24" ON CENTER (8) 5/8" HILTI KWIK BOLT TZ, MIN (2) CONNECTIONS HALF EACH SHORT SIDE. ALONG EACH SIDE CENTER ON CURB BOTTOM. (ICC-ES ESR-1917) SCALE: NTS (((CanFab I TUS2 andCANNON FABRICATION INC _ 182 GRANITE STREET, SUITE 101, CORONA, CA 92879 PART NO: SEE ABOVE PHONE:(951)278-1830 FAX:(951)278-8444 www.confab.com canfab®confab.com DRAWING NO: DATE: APPROVED BY: DATE: / /