Report (29) k( \ S,J W \�, AT Metropolitan Air.Technology The leader in air flow control technology The RT-150 Series Ill Submittal Data Project: Date: Architect: Engineer: Contractor: Design& Materials A. Galvanized steel radial damper velocity loaded to hold setting.Also available in aluminum and stainless steel. B. Damper pivot accepts rotary cable. Alk -f A C. Cable lengths as required up to 12'. 1/4" brass plated steel rotary cable. D. Nylon cable clamp for field furnished with 5/16" hex self-drilling screw. E. Male square rotary cable end adjusts with a 24"STANDARD standard hex nut driver(by others)or the MAT OR UP TO 12' square nut driver. Optional:thin-blade screwdriver AS REQUIRED adjusted cable tip. B C Features • Furnished one piece for easy installation. • Cable minimum turn radius=4". I 3.25" • Operating temperature limits=-40°to 240° F. • Maximum recommended velocity=1600 FPM. • f D • No linkages or cable to adjust. I 0-1/4" • No small loose parts to get lost. f E • Dampers may be installed in any plane. • See Model RT-100 for square/rectangular US PATENT#5,702,298 damper units. CANADIAN PATENT#2,185,311 Available Sizes 60/70/80/100/120/140/150 Location/System Qty. Duct Nominal Dia. Material Cable Length Miscellaneous 6235 South Oak Park Avenue Chicago,IL 60638 USA Represented by: Toll free:800.585.7686 708.552.4040 Fax:708.594.0396 www.metairtech.com ©2008 Steelhead Corp.All rights reserved_ r411 vMAT Metropolitan Air Technology The leader in air flow control technology INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS REMOTE CONTROL DAMPER MODEL RT-150 (ROUND) Please read completely before installing this equipment. RECEIPT INSPECTION: Check material received against packing list. Claims resulting from factory errors must be made within 2 weeks after receipt of goods. INSTALLATION(Reference illustrations on opposite side): 1.Round dampers are furnished as one piece; however, make sure cable end is secure in damper pivot coupling prior to installing. 2.Secure damper in position in duct. Screw or rivet through bearing bracket side pieces-minimum 1 screw per side. Preferred installation method is via#10 speed screws. Do not rack or distort damper. Dampers are 1/4"undersized from nominal dimensions. Position damper to allow best cable run, avoiding tight turns, while keeping adjustment end in its preferred accessible position. Keep adjustment end of cable within 5"of accessible opening if possible. Alternately cables may be left hanging out of ceiling upon installation of air outlet and slipped back in after balancing. 3.Secure the adjustment end of the cable using the nylon clamp. The clamp may be positioned anywhere along cable length to keep adjustment end in accessible position. Do not over tighten. Cable should rotate easily inside the clamp. OPERATION: Dampers may be adjusted by applying a MAT Square Nut driver or a 1/4" hex socket to the male square adjustment end of the cable. Once set,dampers will hold their settings up through the design velocity limits. MAT Square Nut Drivers with 5" shaft length may be purchased from the manufacturer. Optional screwdriver tip units are adjusted with a thin bladed screwdriver. MAINTENANCE: Properly installed Roto-TwistTM dampers require no maintenance of any kind. METROPOLITAN AIR TECHNOLOGY,LLC 6235 SOUTH OAK PARK AVENUE CHICAGO,IL 60638 (708)552-4040 FAX(708)594-0396 www.metairtech.com Rev 7/30/07 i v RT- 150 SERIES AS INSTALLED,BEFORE BALANCING *10 SPEED SCREWS-MIN 1 PER SIDE (NOT PROVIDED) a 1101-m 111 ALTERNATE FiOTO-TWIST- LOCATIONfr ROUND DAMPER Mr 111 Nk,.....„ TAKE OFF(S) AS REQUIRED CABLE LENGTHS 24"STANDARD, PLENUM- AS REOLNRED BY OTHERS UP TO 120" — — — — II —1 •`41----___ADJUSTAELE , NYLON CLAMP MOUNTING CLAMP (OPTIONAL) GWB CEILING _ enhallialloall4M11. ELEVATION \\\. SECTION LINEAR SLOT DIFFUSER BY OTHERS ADJUSTS WITH 1/4"NUTDRIVER./' SPECIFY OPTIONAL SCREW- DRIVER TIP IF LESS THAN 3,8" CLEAR ACCESS SK-150-2.3 NTS SERIES III RT- 150 SERIES AFTER BALANCING lip. W ALTERNATE -----.. ROTO-TWIST'- „iv— LOCATION ATE T hb/”.,,willi ROUND DAMPER ------0- 411P M -.......„... 'N....._ TAKE OFF(S) AS REQUIRED CABLE LENGTHS 24STANDARD, PLENUM- AS REOL$RED BY OTHERS UP TO 120' —— —— —I -",--------ADJUSTABLE . NYLON CLAMP MOUNTING CLAMP (OPTIONAL) OWE CEILING—\ S ———— :1111411r 4111011114011.10001111. ____ ELEVATION N. SECTION LINEAR RIOT DIFFUSER .11\ ACTUATION CABLE BY OTHERS IS RECESSED BEHIND THE DIFFUSER FACE SK-150-2.3 NTS SERIES III