Loading...
Report (26) :_mm.mm•mmmmmmmmmmmmmmmmmmmi......._____, CO?3,4 \ c,,Sh, . OFFICk copy JOHNSON AI P PRODUCTS I SUBMITTAL Fans and Vents by Greenheck Project: Jaguar Land Rover Project Address: 10125 Washington Square Rd Portland, OR Architect: Engineer: HVAC, Inc. General Contractor: Perlo Construction Mechanical Contractor: HVAC, Inc. Date: 3/19/2019 Project: Jaguar Land Rover Project ID: P18-0683 AIR PRQU1J(TTS Table of Contents Tab Submittal Spec/Sub Page# 1 Fans and Vents by Greenheck N/A N/A Greenheck- Fan Schedule_3.19.19 4 Greenheck- Fan Submittal_3.19.19 6 Project: Jaguar Land Rover Project ID: P18-0683 JOHNSON AIR PRODUCTS Spec Section: N/A See M2 Schedules Sub Section: N/A Submittal Name U t Fans and Vents by Greenheck 'n V Vendor/Subcontractor cn Johnson Air Products Danny Ruby U_ F- Jaguar Land Rover EQUIPMENT SCHEDULE Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. Motor Starter (CFM) (is n.wg) RPM (hp) (hp) - - - REF-S-1 1 G-133-B 13.125 800 0.25 781 0.06 51 5.5 1/6 115 60 1 ODP 1140 - Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. s Motor Starter (CFM) (in.wg) RPM - (hp) - (hp) REF-S-2 1 G-103-B 11.125 500 0.25 877 0.04 43 3.3 1/6 115 60 1 ODP 1140 - Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. s Motor Starter (CFM) (in.wg) RPM (hp) (hp) - - REF-C-1 1 GB-2201-1P-7 24 4,060 0.25 725 0.64 62 12.1 3/4 460 60 3 ODP 1725 - No Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Motor Starter Mark Qty Model Dia. RPM s (hp) (CFM) _ (in.wg) (hp) EF-N-2,3,4 3 SBE-3H30-7 30 5,400 0.349 776 0.61 69 17.6 3/4 460 60 3 ODP 1725 - No Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. s Motor Starter (CFM) (in.wg) RPM (hp) (hp) - EF-N-5 1 SE1-12-432-E 12 400 0.183 964 0.04 45 4.0 1/20 115 60 1 TEAO 1050 - Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. s Motor Starter (CFM) (in.wg) - RPM (hp) (hp) EF-N-6 1 SE1-12-432-A4 12 1,000 0.328 1626 0.14 58 9.0 1/4 115 60 1 TEFC 1750 - Fans Actual Performance Motor Specifications Total FanSize EC Motor Wheel Volume External SP Power dBA Sone Volt Hz Ph Enc RPM Mark Qty Model Dia. S Motor Starter (CFM) (in.wg) RPM (hp) (hp) - EF-C-1 (Revised-Inline) 1 BSQ-160-10 16.625 3,400 0.25 1250 0.73 66 14.8 1 460 60 3 ODP 1725 - No CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 1 of 2 !Jaguar Land Rover EQUIPMENT SCHEDULE 4 Fans Actual Performance Motor Specifications Mark Qty Model Wheel Volume Total External Fan Power dBA Sones Amps Volt Hz Ph Enc RPM EC Dia. (CFM) (in.wg) RPM (W) Motor i EF-P-1 1 SP-A110 5.5 95 0.25 950 18 29 0.9 0.58 115 60 1 ODP 950 - Fans Actual Performance Motor Specifications Wheel Volume Total Fan Power Sone Size Mark Qty Model External SP dBA Volt Hz Ph Enc RPM EC Motor Dia. (CFM) (in.wg) RPM (hp) s (hp) Motor Starter EFI-N-1 Inline 1 SQ-120-B 13.125 1,000 0.328 1117 0.13 53 6.1 1/6 115 60 1 ODP 1140 - ID# Tag Mark Name Qty Model 5-1 Elevator Elevator Relief 1 FGR-24x24 Relief Hood ID# Tag Mark Name Qty Model 6-1 LV-C-1 LV-C-1 (Revised- 1 FGI-30x30 Intake Hood) GAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 2 of 2 AlOGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B fd 28.40 - Model: G-133-B Direct Drive Centrifugal Roof Exhaust Fan _ I 23.80 ! 1.75 35.80 Dimensional Quantity 1 (12.00) Weight w/o Acc's(Ib) j 49 Weight w/Acc's(Ib) 89 Max T Motor Frame Sizeli 56 Optional Damper(in.) 12 x 12 19.00 SQ Roof Opening(in.) 14.5 x 14.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 0.35 0.28 78/ RPM Requested Volume(CFM) ' 800 Actual Volume(CFM) 800 0.30 • -- 0.24 Total External SP(in.w—Ig) 0.25 Fan RPM 781 0.25 I_ _ 0.20 Operating Power(hp) 0.06 Elevation(ft) 108 0.20 — 0.16 s Airstream Temp.(F) 70 Air Density( (Ib/ft3) 0.075 0.15 --a� 0.12 Tip Speed ft/min 2,684 a� I Y m Static Eff.(%) 57 a h 0.08 m 0.10 ------ - \ 0.05 ; 0.04 Motor 0.00 0.00 Motor Mounted Yes 0 2 4 6 8 10 12 Size(hp) 1/6 Volume(CFM)x 100 Voltage/Cycle/Phase j 115/60/1 Enclosure ODP A Operating Bhp point 0 Operating point at Total External SP Motor RPM 1140 Fan curve Windings 1 - - - -System curve Brake horsepower curve Notes: All dimensions shown are in units of in. *Please consult factory for actual motor amp draw aOIT1CDBQ' Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 CERTInED dBA-A weighted sound pressure level,based on 11.5 dB RRTIOGf Soundattenuation per Octave band at 5 ft-dBA levels are not fOVAD Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones licensed by AMCA International Sones-calculated using AMCA 301 at 5 ft \ RIR Inlet 71 68 62 60 56 54 43 38 62 51 5.5 PEPSORR1000E 111 COMMIT artocomonnonl % urren011i1(1nnt IAC.�09 Generated by:'fisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 1 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B Model: G-133-B Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: PSC Motor UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Roof Curb-Galv.,GPI-19-G12,Under Sized 1.5 in.Total, 1 in. Insulation Damper Shipped Loose,VCD-23-PB-12X12,Not Coated Damper Actuator, 115 VAC Actuated Solid State Speed Control,6 Amp,Shipped Loose Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 20181G-I\Jaguar Land-Rnver,gfcj Paue-2-&-GA OGREENHECK Printed Date: 03/19/2019Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/6 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1140 Exp. Resist.Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 Wiring (4 HOLES) Schematic O 0 O 4.35 1.06 O O O 1.65 O 60.72 — 2.00 ---- 1.06 r 2.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 3 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING 12.00 14.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE 0 28.40 23.80 1.75 35.80 L J t (12.00) i 1 i 19.00 SQ DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 20181 - .• . ... :• - • ' Printed Date: 03/19/2019 ®GREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame -Galvanized blades with reinforcements- Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.- Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized- Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Belimo Jackshaft Quantity: 0 Model: TFB120 Mounting: Internal Quantity: 1 `< 1.3 , max. 12 �� n 10.0 12 } X X" ,,A ` I, 5.0 Min. 1.3 max. DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 5 of 67 1GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure- Constructed of either 18 ga galvanized steel or 0.064 in. aluminum- Straight Sided without a cant-2 in. mounting flange- 3 lb density insulation - Height- Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 17.55 17.55 12.00 1111 21 .50 21 .50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2418\G-L\Jafluar Land Roverijfrj Pogo 6 of 67 Printed Date: 03/19/2019 �GREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-1 Model: G-133-B AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOURD 111R PERFORMAACE AIR kitee AIOYEAIEnr k! AAD COATROt 0% AflOCIATIOA o4:9 IATERAATIOAAL. IAC.— AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 7 of 67 AlOGREEHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Model: G-103-B -024.40--. Direct Drive Centrifugal Roof Exhaust Fan 1 23.70 1 ' [1.75 35.70 Dimensional Quantity 1 Weight w/o Acc's(Ib) 43 (12.00) Weight w/Acc's(Ib) 83 Max T Motor Frame Size 56 Optional Damper(in.) 12 x 12 19.00 SQ-� Roof Opening(in.) 14.5 x 14.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 0.35 0.28 Requested Volume(CFM) 500 877 FRPM Actual Volume(CFM) 500 0.30 ------ i." 0.24 Total External SP(in.wg) 0.25 Fan RPM 877 0.25 Operating Power(hp) 0.04 �� 0.20 Elevation(ft) 108 c 0.20 a - — - - 0.16 Airstream Temp.(F) 70 , Air Density(Ib/ft3) 0.075 w 1� Tip Speed(ft/min) 2,556 0.15 r --- -- 0.12 i Static Eff.(%) 51 D- .cI y cv cci 0.10 . 0.08 m` o� 0.05 co e --- j -- ___L --- 0.04 Motor 0.00 - 0.00 Motor Mounted Yes 0 1 2 3 4 5 6 7 8 Size(hp) 1/6 Volume(CFM)x 100 Voltage/Cycle/Phase 115/60/1 Enclosure ODP L Operating Bhp point Motor RPM 1140 0 Operating point at Total External SP Fan curve Windings 1 - -- -System curve Brake horsepower curve Notes: All dimensions shown are in units of in. *Please consult factory for actual motor amp draw Qmc Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 WORIDRIIDE dBA-A weighted sound pressure level,based on 11.5 dB OERTMED Sound RRTIR 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones attenuation per Octave band at 5 ft-dBA levels are not Data licenseded b AMCA International AMID Inlet 65 58 60 51 43 41 34 25 54 43 3.3 Sones-calculated using AMCA 301 at 5 ft D FIRM All ZvemEnr E, nunnnnonm.Inc. ' Generated by:jfisher@johnsonair.com CAPS 4.28.1746 _Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 8 of b/ 01.GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Model: G-103-B Direct Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined composite(sizes 60-95)or aluminum (sizes 97-300)wheel-Aluminum curb cap with prepunched mounting holes- Birdscreen-Ball bearing motors(sizes 85-300 and all Vari Green),sleeve bearing motors(sizes 60-80)-Motor isolated on shock mounts-Corrosion resistant fasteners Selected Options &Accessories: PSC Motor UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Roof Curb-Galv.,GPI-19-G12,Under Sized 1.5 in.Total, 1 in. Insulation Damper Shipped Loose,VCD-23-PB-12X12,Not Coated Damper Actuator, 115 VAC Actuated Solid State Speed Control,6 Amp,Shipped Loose Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 9 of 67 filGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/6 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1140 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic O 4.35 1.06 O O Q 1.65 O 0.72 2.00 — •I -- 1.06 --.- 2.50 2.50 —Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4 28 1746 Y•\Aar•. . .._ . - ... e : _—L\Jaguar Land Rovcr.gfcj Page 10 of G7 LEI GREENHECK Printed Date: 03/19/2019 • Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Assembly Drawing Type: Direct Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING 12.00 14.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE A 0 24.40 23.70 I 1 1.75 35.70 (12.00) 1 1 19.00 SQA DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 11 of 67 GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications- Galvanized 16 ga channel frame- Galvanized blades with reinforcements- Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Belimo Jackshaft Quantity: 0 Model: TFB120 Mounting: Internal Quantity: 1 < 1.3 12 `/ m ` � � ax. 10.0 12 + ,(t �" �` � 5.0 Min. �1 1.3 J max. DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 20181G J\.tag lar Land Rover.gfci - --- Page 12 of 87 ifiGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure-Constructed of either 18 ga galvanized steel or 0.064 in. aluminum- Straight Sided without a cant-2 in. mounting flange- 3 lb density insulation - Height- Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 17.55 17.55 12.00 21 .50 21 .50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 13 of 67 �GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-S-2 Model: G-103-B AMCA anima WORLDWIDE CERTIFIED RRTIAGS SOUAD nne AIR FERfORMAACE AIR tp MOVEAIEAT (to Ann COATROI •o% ASSOCIATIOA er IATERAATIOAAI. inc."' 9 AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 14 of 67 Printed Date: 03/19/2019 ®GREENHECK Job: Jaguar Land Rover ® Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 PJ 42.80 Model: GB-220HP-7 Belt Drive Centrifugal Roof Exhaust Fan _ i I 31.50 43.50 1.75 Dimensional Quantity 1 ` i (12.00) Weight w/o Acc's(Ib) 110 Weight w/Acc's(Ib) 185 t Max T Motor Frame Size 184 --34.00 SQ Optional Damper(in.) 24 x 24 Roof Opening(in.) 26.5 x 26.5 OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Performance 1.2 0.8 Requested Volume(CFM) 4,060 725 FRPM Actual Volume(CFM) 4,060 ---------------------- Total External SP(in.wg) 0.25l ,` Fan RPM 725 0.9 0.6 Operating Power(hp) 0.64 lisi I _ Elevation(ft) 108 , L Airstream Temp.(F) 70 `'' ! 1 0.4 Air Density(Ib/ft3) 0.075 = o a 0_ Drive Loss(%) 7.4 a� o b Y Tip Speed(ft/min) 4,557 a y 1 Static Eff.(%) 27 0.3 e, i m in ate . oQ - c co system-..-..-1.... Motor 0.0 1. .1-.i_ l-.-I-1r ir 1 I H 1 1 l H i l l i 1 1 1 ' ' 0.0 Motor Mounted Yes 0 5 10 15 20 25 30 35 40 45 Size(hp) 3/4 Volume(CFM)x 100 Voltage/Cycle/Phase 11 460/60/3--— -- Enclosure • ODP L\ Operating Bhp point Motor RPM 1725 0 Operating point at Total External SP Fan curve Windings 1 -.-- -System curve NEC FLA*(Amps) 1.6 Brake horsepower curve Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of amCQ National Electrical Code 2014.Actual motor FLA may vary, Eo E CERTIFSound Power by Octave Band for sizing thermal overload,consult factory. RETIREE SoundLwA-A weighted sound power level,based on ANSI S1.4 62.5 125 250 500 1000 2000w 4000 8000 LA dBA Sones foueD DatadBA-A weighted sound pressure level,based on 11.5 dB D attenuation per Octave band at 5 ft-dBA levels are not Inlet 77 80 75 70 66 66 61 56 74 62 12.1 licensed by AMCA International ,ExroR pneRE Sones-calculated using AMCA 301 at 5 ft mn eF, mcvcmenr e, no conrnol °yen assneinrion InI011.1011 .IOC e' Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 15 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 Model: GB-220HP-7 Belt Drive Centrifugal Roof Exhaust Fan Standard Construction Features: -Aluminum housing-Backward inclined aluminum wheel-Curb cap with prepunched mounting holes-Motor and drives isolated on shock mounts- Birdscreen-Ball bearing motors-Adjustable motor pulley-Adjustable motor plate-Fan shaft mounted in ball bearing pillow blocks-Bearings meet or exceed temperature rating of fan-Static resistant belts-Corrosion resistant fasteners- Sizes 141 and larger have internal Lifting lugs Selected Options &Accessories: High Efficient Motor-meets Greenheck High Efficiency Table UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Roof Curb-Galv.,GPI-34-G12,Under Sized 1.5 in.Total, 1 in. Insulation Damper Shipped Loose,VCD-23-PB-24X24,Not Coated Damper Actuator, 115 VAC Actuated Bearings with Grease Fittings,L10 life of 100,000 hrs(L50 avg.life 500,000 hrs) Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 16 of 67 ®GREENHECK Printed Date: 03/19/2019 - Job: Jaguar Land Rover ® Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 3/4 hp Voltage: 460 UL Listed: Yes Manufacturer: Square D Cycle: 60 Amperage: 30 CSA Approved: Yes Overload Protection: None Phase: 3 Switch Pole(s): 3 Rating: 10 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details I0 C Wiring Schematic O O 3.00 4.25 a IC \j 0.56 r 0.41 O Q O 22.75 —1.63-- 2.88 2.44 ■ O 6 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 17 of 67 GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 Assembly Drawing Type: Belt Drive Centrifugal Roof Exhaust Fan SUGGESTED ROOF OPENING I , r ____�I I 24.00 26.50 SQ SQ RECOMMENDED EXHAUST DUCT SIZE 0 42.80 31.50 43.50 [1.75 L J t (12.00) 34.00 SQ DUCT DIMENSIONS ARE LARGEST POSSIBLE DUCT TO FIT THROUGH CURB. CONSULT SYSTEM DESIGN ENGINEER FOR RECOMMENDED DUCT SIZE. OVERALL HEIGHT MAY BE GREATER DEPENDING ON MOTOR. Notes:All dimensionsh s own are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2418\G-L\Jaguar 1 and Rover gfcj _ Page 18 of 67 ffGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-C-1 Model: GB-22OHP-7 Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame -Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Belimo Jackshaft Quantity: 0 Model: TFB120 Mounting: Internal Quantity: 1 ` <. 1.3 � max. 10.0 2` Min. 24 } + 5.0 1.3 max. DAMPER TYP.SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 19 of 67 'GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 Roof Curb Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure-Constructed of either 18 ga galvanized steel or 0.064 in. aluminum -Straight Sided without a cant-2 in. mounting flange-3 lb density insulation - Height- Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 32.55 32.55 illo 12.00 _ .".- 36.50 36.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28 1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 20 of 67 • [6f Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: REF-C-1 Model: GB-220HP-7 AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOURD nnp RIR PEREORMAACE AIR Qin 111OVEn1EAT ki nil!)COATROt .qac n$JocIATIon IATERAATIOAAI. IAC.'' AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) includes transmission losses. Performance ratings include the effects of birdscreen. The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 21 of 67 DIGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Model: SBE-3H30-7 44.00 < 29.13-- Sidewall Belt Drive Fan I \v Motor Access From Int. of Bldg. �II1 1.4 E f 36.50 .II—--a- Dimensional Quantity 3 GUARD i l WEATHERHOOD IWeight w/o Acc's(Ib) 101 WALL HOUSING Weight w/Acc's(Ib) 327 DAMPER INTER R `1 EXTERIOR Max T Motor Frame Size 184 EXHAUST AIRFLOW Optional Damper(in.) 32 x 32 Wall Opening(in.) 39.75 x 39.75 Performance 0.8 1.2 Requested Volume(CFM) 5,400 -j s� Actual Volume(CFM) 5,400 N .O Total External SP(in.wg) 0.349 `.27 Fan RPM 776 0.6 0.9 Operating Power(hp) 0.61 Elevation(ft) 108 ca Airstream Temp.(F) 70 d m. ". r i .�1. 0.6 N Air Density(Ib/ft3) 0.075 0.4 o Drive Loss(%) 7.6 b? �' a Tip Speed(ft/min) 6,091 -cm Static Eff.(%) 52 2 0.2 co AQP Motor \0.0 0.0 Motor Mounted Yes 0 1 2 3 4 5 6 7 8 9 Size(hp) 3/4 Volume(CFM)x 1,000 Voltage/Cycle/Phase 460/60/3 Enclosure ODP ,L Operating Bhp point Static Pressure Calculations Motor RPM 1725 0 Operating point at Total External SP External SP Fan curve 0.2 in.wg Windings 1 -••- System curve Damper 0.114 in.wg NEC FLA'(Amps) 1.6 - Brake horsepower curve Wall Housing 0.035 in.wg Total External SP 0.349 in.wg Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of QmClla Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, oERTIWIDDE for sizing thermal overload,consult factory. RRTIRGS Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones LwA-A weighted sound ppower level,based on ANSI S1.4 Data dBA-A wei hted sound ressure level,based on 11.5 dB S�A� attenuation per Octave band at 5 ft-dBA levels are not Inlet 83 81 82 78 74 72 68 64 81 69 17.6 licensed by AMCA International `n a roenieR Sones-calculated using AMCA 301 at 5 ft nin 44 movmmcnr "x COO eonvnol 'a, nssocmnon 'off m onnnonm.Inc. CAPS 4.28.1746 Y Generated by:jfisher@johnsonair.com �4aronnorrpqcL g ._ n °\C UJeguar Land Ruvdr.gkj Page 22 of 67 U1GREENHECK Printed Date: 03/19/2019 •Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Model: SBE-3H30-7 Sidewall Belt Drive Fan Tags:EF-N-2 EF-N-3 EF-N-4 Standard Construction Features: Galvanized steel fan panel-Die formed,galvanized steel drive frame assembly -Fabricated steel propeller for Levels 1 and 2,welded and painted steel for Level 3-Adjustable motor pulley-Ball bearing motors-Fan shaft mounted in ball bearing pillow blocks-Static resistant belts-Corrosion resistant fasteners Selected Options &Accessories: Motor with Thermal Overload UL/cUL 705 Listed-"Power Ventilators" Airflow Direction:Exhaust Damper Mounted,WD-320-PB-32X32,Not Coated Damper Actuator, 115 VAC Actuated Long Wall Hsg,Flush Exterior,w/OSHA Grd. Motor Access:From Int.of Bldg. Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Weatherhood,Galvanized 45 deg.with Bird Screen Bearings with Grease Fittings Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 23 of 67 �GREENHECK Printed Date: 03/19/2019 Building Value in Air. Job: Jaguar Land Rover Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 3/4 hp Voltage: 460 UL Listed: Yes Manufacturer: Square D Cycle: 60 Amperage: 30 CSA Approved: Yes Overload Protection: None Phase: 3 Switch Pole(s): 3 Rating: 10 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details F C Wiring Schematic OFF 3.00 4.25 .r-} o — e 0.156 ik 2.75 — -- 0.41 --.1.63•-- O O O 2 .88 2.44 ■ n • Notes:AU dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured .. I : - _. _ _.. • GREENHECK Job:Printed JaguarDate:Land03/19/2019 Rover - ® Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Assembly Drawing Type: Sidewall Belt Drive Fan 44.00 29.13-- DRAWING VIEWED FROM INTERIOR I v 4- 38.25 44.25 ' 'i' 36.50 WEATHERHOOD 38.25 GUARD I 44.25 WALL HOUSING INTERIOR I EXTERIOR DAMPER END VIEW DIMENSIONS ARE FOR HOUSING NOT FAN PANEL EXHAUST AIRFLOW WALL OPENING 39.75 SQ. MOTOR IS ACCESSIBLE FROM INTERIOR OF BUILDING THIS IS AN EXHAUST FAN DUE TO MOTOR ORIENTATION THIS FAN HAS 6 BLADES Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com Page 25 of 67 CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj g IPrinted Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Vertical Mount Exhaust Damper Model: WD-320 Standard Construction Features: - Model WD-320 is a vertical mount exhaust damper and is constructed of 18 ga galvanized steel with pre-punched mounting holes and a flanged frame- Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge-Steel axles are 0.188 in. diameter zinc plated mounted steel in nylon bushings-Synthetic axle bearings Damper Configuration: Actuator Type: 115 VAC End Switch: No Actuator Configuration: Manufacturer: Greenheck Jackshaft Quantity: 0 Model: MP-310 Mounting: Internal Quantity: 1 —1.5 II II 11.11 111111:0- 3.5 I 2.75 IX111 I�I�I32 32 DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.125 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 ___Y:1AaronCormack\Secured Jnhs 7n9R\G-Lk jaguar Land Rover.gf^j rage 20 of 87 Printed Date: 03/19/2019 - IGREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 45 Degree Weatherhood Standard Construction Features: Galvanized Steel or aluminum construction. 0.5 welded wire birdscreen. Prepunched mounting holes. Field assembled. 35.125 - - 29.125 Irb 36.5 SIDE VIEW ELEVATION VIEW Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 27 of 67 I"IGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 Long Wall Housing Standard Construction Features: - Galvanized steel construction - Heavy gauge mounting flanges - Pre-punched mounting holes - Inside flanges allow damper to be mounted - Overlapping weatherhood flange keeps rain out - OSHA Protective guard of welded steel wire completely protects the drive side of the wall housing. 44 ► 38.25 41% rNs0 38.25 3 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Johs 20181G-LUaguar Land Rover.gfcj Page 28 of 87 111GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-2, 3, 4 Model: SBE-3H30-7 AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOURD ADD RIR PERrORmnnCE RIR mOVERIEAT 4! RDD COATROI 9% nfJOCIRTIOR ,O4. IATERAATIOARI. Inc. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW) includes transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 29 of 67 ESGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Model: SE1 -12-432-E Sidewall Direct Drive Fan - 29.00 16,38 Motor Access From Int. of Bldg. \/ I I i i Dimensional i ��' 1 15.63 Quantity 1 Weight w/o Acc's(Ib) 30 r WEATHERHOOD GURD Weight w/Acc's(Ib) 101 WALL HOUSING I I Optional Damper(in.) 14 x 14 DAMPER Wall Opening(in.) 19.25 x 19.25 I I INTERIOR t___j EXTERIOR EXHAUST AIRFLOW Performance 0.35 0.21 • • Requested Volume(CFM) 400 964 ,< Actual Volume(CFM) 400 0.30 141 0.18 Total External SP(in.wg) 0.183 if Fan RPM 964 0.25 0.15 • Operating Power(hp) 0.04 Elevation(ft) 108 •c 0.20 0.12 - Airstream Temp.(F) 70 S—) 1, t Air Density(Ib/ft3) 0.075 = a° u0.151 0.09 a Tip Speed(ft/min) 3,029 ds I / _ D_ i Static Eff.(%) 29 D- ,-.C.- Y F_ .10.10 - - 0.06co } o, Q '�_------�--_---- 0.05 �o ��„e,`.. 0.03 O° o, , Motor 0.00 � \ 0.00 Motor Mounted Yes 0 1 2 3 4 5 6 7 8 9 10 Size(hp) 1/20(or greater) Volume (CFM)x 100 Voltage/Cycle/Phase 115/60/1 Enclosure TEAO Operating Bhp point Static Pressure Calculations Motor RPM 1050 0 �an cu a perating point at Total External SP External SP 0.125 in.wg Windings , 1 - - - -System curve Damper 0.046 in.wg Brake horsepower curve Wall Housing 0.011 in.wg Total External SP 0.183 in.wg Notes: All dimensions shown are in units of in. *Please consult factory for actual motor amp draw QmCQ Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 WOODRUM dBA-A weighted sound pressure level,based on 11.5 dB MIM Sound 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones attenuation per Octave band at 5 ft-dBA levels are not Data licensed by AMCA International fOYOD Sones-calculated using AMCA 301 at 5 ft Inlet 70 67 48 48 50 48 42 35 56 45 4.0 D .evomia nm m Dnmenr e n conrnol .N. rolocmnon InunannonnI.in<.��Y Generated by:jfisher@johnsonair.com CAPS 4 98 1746, Y/AaronCormack\Secured Jobs-201816=L\Jaguar Land Rover.gftj Page 30 of 67 Printed Date: 03/19/2019 • GREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Model: SE1-12-432-E Sidewall Direct Drive Fan Standard Construction Features: -Fan panels of galvanized steel-Aluminum blade propeller-Heavy gauge welded wire motor supports and fan guard that is Zinc plated-Motor mounted to support guard with neoprene isolators-Corrosion resistant fasteners Selected Options &Accessories: Motor with Thermal Overload UL/cUL 705 Listed-"Power Ventilators" Airflow Direction:Exhaust Damper Mounted,WD-320-PB-14X14,End Switch,Not Coated Damper Actuator, 115 VAC Actuated Long Wall Hsg,Flush Exterior,w/OSHA Grd. Motor Access:From Int.of Bldg. Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Weatherhood,Galvanized 45 deg.with Bird Screen Solid State Speed Control,6 Amp,Shipped Loose Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 31 of 67 EHGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/20 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1050 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic O 4.35 k 0 • 1.06 O O 0 1.65 O )100.72 — -- 2.00 --- -.-- —.-- 1.06 2.50 '— Notes: Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar 1 and Rover gfrj Page 32 of G7 U1GREENHECK Printed Date: 03/19/2019 • Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Assembly Drawing Type: Sidewall Direct Drive Fan <\\ N ` 29.00 16,38—,- 1 DRAWING VIEWED FROM INTERIOR F*11:11 f15.63 18.25 21.25 '- _i 1 WEATHERHOOD GUARD 1281.25 { WALL HOUSING 11 DAMPER 1 END VIEW DIMENSIONS ARE FOR HOUSING NOT FAN PANEL INTERIOR L_ 1 EXTERIOR WALL OPENING 19.25 SQ. MOTOR IS ACCESSIBLE FROM INTERIOR OF BUILDING THIS IS AN EXHAUST FAN DUE TO MOTOR ORIENTATION THIS FAN HAS 4 BLADES EXHAUST AIRFLOW Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 33 of 67 �GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Vertical Mount Exhaust Damper Model: WD-320 Standard Construction Features: - Model WD-320 is a vertical mount exhaust damper and is constructed of 18 ga galvanized steel with pre-punched mounting holes and a flanged frame- Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge- Steel axles are 0.188 in. diameter zinc plated mounted steel in nylon bushings-Synthetic axle bearings Damper Configuration: Actuator Type: 115 VAC End Switch: Yes Actuator Configuration: Manufacturer: Greenheck Jackshaft Quantity: 0 Model: MP-310 Mounting: Internal Quantity: 1 I• -1.5 II 0I } II2.75 11111 1111 11111 ': I 1111 1111 X111 14 3.5 -- 14 DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.125 in.undersize Generated by:jfisher@johnsonair.com AP A . -. • A- . . mack\Secured Jobs-2018\G--LW-guar-Land Rever.gfej Page-Sit-of-017 Printed Date: 03/19/2019 �GREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E 45 Degree Weatherhood Standard Construction Features: Galvanized Steel or aluminum construction. 0.5 welded wire birdscreen. Prepunched mounting holes. Field assembled. 14.5 16.375 IP15.625 • SIDE VIEW ELEVATION VIEW Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 35 of 67 'GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E Long Wall Housing Standard Construction Features: - Galvanized steel construction - Heavy gauge mounting flanges - Pre-punched mounting holes - Inside flanges allow damper to be mounted - Overlapping weatherhood flange keeps rain out - OSHA Protective guard of welded steel wire completely protects the drive side of the wall housing. 29 4NN18.25 01 �\► `\ 18.25 NNN 1.5 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 20181G-L1.1a0nari and_Rctuer-gfo} Page-36-of-67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-5 Model: SE1-12-432-E AMCA amca WORLDWIDE CERTIFIED RRTIRGS SQUAD RIR PEREORmnncE RIR mOVERIERT ! RR1�CORTROI 9% RSSOCIRTIOR Qom IRTERRRTIORRI. IRC." AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances(accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 37 of 67 LGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Model: SE1 -12-432-A4 Sidewall Direct Drive Fan - 2900 �\ 16,38-- Motor Access From Int. of Bldg. 1 u 1 1 1 Dimensional ���1' �;1 15.63 Quantity 1 1 II Weight w/o Acc's(Ib) 41 V WEATHERHOOD Weight w/Acc's(Ib) 112 GUARD I WALL HOUSING Max T Motor Frame Size 0 DAMPER I Optional Damper(in.) 14 x 14 � Wall Opening(in.) 19.25 x 19.25 INTERIOR !_I EXTERIOR EXHAUST AIRFLOW Performance 1.2 0.4 Requested Volume(CFM) 1,000 Actual Volume(CFM) 1,000 Total External SP(in.wg) 0.328 1626-,. 62g � Fan RPM 1626 _ ` iQ,p ------- ____ 0.3 Operating Power(hp) 0.14 ,..7- ___ Elevat - Elevation(ft) 108 -- _-; Airstream Temp.(F) 70 Air Density(Ib/ft3) 0.075 92 0.6 0.2 o Tip Speed(ft/min) 5,107 m r`� Static Eff.(%) 36 Y --- f° i� 0.3 ,m — --� — 0.1 m 0 c°� o° Motor 0.0 -1-4----r i l . 0.0 Motor Mounted Yes 0 2 4 6 8 10 12 14 16 Size(hp) 1/4 Volume(CFM)x 100 Voltage/Cycle/Phase 115/60/1 Enclosure TEFC , . Operating Bhp point Static Pressure Calculations Motor RPM 1750 O Operating point at Total External SP External SP Fan curve 0.2 in.wg Windings 1 - -- -System curve Damper 0.057 in.wg _ Brake horsepower curve Wall Housing 0.071 in.wg Total External SP 0.328 in.wg Notes: All dimensions shown are in units of in. *Please consult factory for actual motor amp draw amc i Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 WORIDRIIDE ourridBA-A weighted sound pressure level,based on 11.5 dB MOGIED Sound attenuation per Octave band at 5 ft-dBA levels are not RRTIREd Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones licensed by AMCA International fOUAD Inlet 76 74 70 64 64 62 57 50 69 58 9.0 Sones-calculated using AMCA 301 at 5 ft DPEIKOR*Ao IR mrt rma :VOMIT N. ono COAT= .N. mwemnen 'e,� 1(17011.1011r14.me.' Generated by:jfisher@johnsonair.com CAPS 4.28.1746 YAAaronCorfnack\Serured lob -201> L,_Wag-Liar-Land Rover.gfcj Page 38 of 6/ ®GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Model: SE1 -12-432-A4 Sidewall Direct Drive Fan Standard Construction Features: -Fan panels of galvanized steel-Aluminum blade propeller-Die formed, galvanized steel drive frame assembly-Corrosion resistant fasteners Selected Options &Accessories: Motor with Thermal Overload PSC Motor UL/cUL 705 Listed-"Power Ventilators" Airflow Direction:Exhaust Damper Mounted,WD-320-PB-14X14,End Switch,Not Coated Damper Actuator, 115 VAC Actuated Long Wall Hsg,Flush Exterior,w/OSHA Grd. Motor Access:From Int.of Bldg. Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Weatherhood,Galvanized 45 deg.with Bird Screen Solid State Speed Control,6 Amp,Shipped Loose Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 39 of 67 • El.GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/4 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1750 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic I O 4.35 • O • 1.06 • • )1 p 1.65 � 0.72 - 2.00--- 1.06 0 2.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronC. u. , - -. .. . : . __., -, - _ --- --- — Paye 40 of 87 fGREENHECK Printed Date: 03/19/2019 • Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Assembly Drawing Type: Sidewall Direct Drive Fan <\\ N ` 29.00 16.38 I DRAWING VIEWED FROM INTERIOR I 15.63 18.25 21.25 I I_11 PI �1 ���� r WEATHERHOOD 1 .25 GUARD I 28 25 i WALL HOUSING I DAMPER I END VIEW DIMENSIONS ARE FOR HOUSING NOT FAN PANEL INTERIOR I EXTERIOR WALL OPENING 19.25 SQ. MOTOR IS ACCESSIBLE FROM INTERIOR OF BUILDING THIS IS AN EXHAUST FAN DUE TO MOTOR ORIENTATION THIS FAN HAS 4 BLADES EXHAUST AIRFLOW Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 41 of 67 • I Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Vertical Mount Exhaust Damper Model: WD-320 Standard Construction Features: - Model WD-320 is a vertical mount exhaust damper and is constructed of 18 ga galvanized steel with pre-punched mounting holes and a flanged frame- Damper blades are 0.025 in. roll formed aluminum with vinyl seals on the closing edge - Steel axles are 0.188 in. diameter zinc plated mounted steel in nylon bushings- Synthetic axle bearings Damper Configuration: Actuator Type: 115 VAC End Switch: Yes Actuator Configuration: Manufacturer: Greenheck Jackshaft Quantity: 0 Model: MP-310 Mounting: Internal Quantity: 1 III0. -1.5 1110' 1110' I 2.75 Illi' EM� 1l,► IIII X111 14 iim III 14 3.5 .a DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.125 in. undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 7018\G-L1 Jaguar Land Rover.gfcj Printed Date: 03/19/2019 • ®GREENHECK Job: Jaguar Land Rover ® Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 45 Degree Weatherhood Standard Construction Features: Galvanized Steel or aluminum construction. 0.5 welded wire birdscreen. Prepunched mounting holes. Field assembled. 14.5 - 16.375 15.625 • SIDE VIEW ELEVATION VIEW Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 43 of 67 • 0 GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 Long Wall Housing Standard Construction Features: - Galvanized steel construction - Heavy gauge mounting flanges - Pre-punched mounting holes - Inside flanges allow damper to be mounted - Overlapping weatherhood flange keeps rain out - OSHA Protective guard of welded steel wire completely protects the drive side of the wall housing. 29 ► 18.25 14 \ 4 18.25 0 .rNs• NN4 1.5 ' Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 20181G-L\Jaguar I and Rnvvr.gfcj Page 44 of 67- Al1#1GREEHECK Printed Date: 03/19/2019 • Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-6 Model: SE1-12-432-A4 AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOURD MID 11IR PERFORmffCE AIR IIIOVEAIERT 4! AAD CORTROI ASO ASSOCIATIOA Qo,„ IRTERAATIORAI. IRC.(' AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type A: Free inlet, Free outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type A: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to sone ratings only. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 45 of 67 �— ,GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 Model: BSQ-160-10 Belt Drive Centrifugal Inline Fan Dimensional Quantity 1 Weight w/o Acc's(Ib) 175 Weight w/Acc's(Ib) 248 Max T Motor Frame Size 184 Optional Damper(in.) 23 x 23 1.5 1.0 7 ,50 FRpnA Performance 1.2 I 0.8 Requested Volume(CFM) 3,400 Actual Volume(CFM) 3,400 Total External SP(in.wg) 025 0.9 0.6 a Fan RPM 1250 - Operating Power(hp) 0.73 2 = � Elevation(ft) 108 0.6 a o a� 0.4 cl- Airstream Temp.(F) 70 o_ <3.) L> co Air Density(Ib/ft3) 0.075 - c m co Drive Loss(%) 7.0 co0.3E`� 0.2 Tip Speed(ft/min) 5,438 c)9* Static Eff.(%) 20 0� \ o° stem ..- .. 0.0 '".J-,+..E.ri iii , .. .lii . 1i , 1iIIIlIyl 00 0 4 8 12 16 20 24 28 32 36 40 Motor Volume(CFM)x 100 Motor Mounted Yes Size(hp) 1 Voltage/Cycle/Phase 460/60/3 L\ Operating Bhp point Enclosure ODP 0 Operating point at Total External SP Fan curve Motor RPM 1725 - - -System curve Windings 1 Brake horsepower curve NEC FLA*(Amps) 2.1 Notes: All dimensions shown are in units of in. *NEC FLA-based on tables 430.248 or 430.250 of amca Sound Power by Octave Band National Electrical Code 2014.Actual motor FLA may vary, WORLDWIDE for sizing thermal overload,consult factory. OERTISROTIAGIED! Sound LwA-A weighted sound power level,based on ANSI S1.4 RTIRG Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones dBA-A weighted sound pressure level,based on 11.5 d8 SOIYOD attenuation Inlet 79 81 81 76 68 68 64 59 78 66 14.8 licensed by per Internationals ft-dBA levels are not D rruonnp oR Radiated 79 80 72 66 55 48 39 35 69 57 8.6 Sones-calculated using AMCA 301 at 5 ft n MID C0017201 °a,o n ocmnon Immanlonnl.111... Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs2018\G-I\.laguar Land Rover.gfcj rage 46 of 67 111GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 Model: BSQ-160-10 Belt Drive Centrifugal Inline Fan Tag:EF-C-1 Standard Construction Features: -Galvanized steel housing-Backward inclined aluminum wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors- Adjustable motor pulley-Adjustable motor plate-Fan shaft mounted in ball bearing pillow blocks-Static free belts-Corrosion resistant fasteners Selected Options &Accessories: NEMA Premium Efficient Motor-meets NEMA Table 12-12 UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Damper Shipped Loose,Inline,VCD-23-OB-23X23,Not Coated Damper Actuator, 115 VAC Actuated Insulated Housing-1 in.Thick:Fan Housing,Motor Cover Motor Cover Isolators&Brackets,Spring Hanging(1 Kit(s):Qty 4,PN:850345)(Shipped Loose) Bearings with Grease Fittings,L10 life of 100,000 hrs(L50 avg.life 500,000 hrs) Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 47 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 BSQ-160-10 Belt Drive Centrifugal Inline Fan 29.01 o. .o i 23.00 TOP VIEW O13.25 MAX Aniumk 39.38 �r 22.88 SQ. INLET 26.13 I 26.13 J 1.50 26.00 f1.50 29.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 • t. • . ••. . . .._apt RIP_ U,gJ P 4 d R^vor.gfcj Payer 48 of 67 Printed Date: 03/19/2019 �GREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1 hp Voltage: 460 UL Listed: Yes Manufacturer: Square D Cycle: 60 Amperage: 30 CSA Approved: Yes Overload Protection: None Phase: 3 Switch Pole(s): 3 Rating: 10 hp Junction Box Mtg.: Mounted and Wired RPM: 1725 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details F 0 Wiring L Schematic OFF 3.00 _ 4.25 e o 11 0.56 0.41O O O 2.75 —.1.63= 2.88 1.63- 2.88 — 2.44 Fl 6 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 49 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 Assembly Drawing Type: Belt Drive Centrifugal Inline Fan 29.01 - LJ, LL E;, 23.00 l ,I TOP VIEW O13.25 MAX k, 39.38 22.88 SQ. INLET 26.13 26.13 1.5 0 26.00 29.00 - END VIEW SIDE VIEW Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCorm. , - -. .. alPrinted Date: 03/19/2019 Job: Jaguar Land Rover ® Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame- Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.- Synthetic axle bearings-Width and height furnished approximately V5a. uner �onf�- Figur wiring is required to individual components ation: Actuator Type: 115 VAC End Switch: No 10.0 -..— Min.Min. ---5.0-- OP. t'llml 110'. II , 1110- Ililli z. I hill • 23 1.I 23 1.3 max. i ..... 1.3 max. DAMPER - INLINE TYP. SECTION VIEW DISCHARGE Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 51 of 67 Al Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-C-1 (Revised-Inline) Model: BSQ-160-10 AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOWID AAI? AIR PERfORAIAACE AIR tp AIOVEAIEAT ski AAI!COATROI •Q% ASSOCIRTIOA •s, IATERAATIOAAI. IAC. AMCA Licensed for Sound and Air Performance. Power rating (BHP/kW) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW)includes transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m)in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured.Inhs 2018\r-I\1ag.ark AwijR.over,gfej Page 52 of 67 OGREENH ECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-P-1 Model: SP-A110 14.625— 14.875 Model: SP-A110 — — Ceiling Exhaust Fan 5.5 13.25 Standard Construction Features: Corrosion resistant galvanized steel scroll and housing-Sound absorbing 1 insulation White designer non-yellowing grille-Outlet duct collar with integral spring loaded backdraft damper-Double inlet forward curved wheel-Plug type disconnect-Adjustable mounting brackets-Field rotatable discharge Selected Options &Accessories: —13.25— 10.625 Motor with Thermal Overload 8 1 F Motor with CSA Approval Motor with 40 Degree C Ambient Temperature Motor rated for continuous use MOUNTING UL/cUL 507 Listed-Electric Fan BRACKET9 6 Designer Grille T—L1 Polypropylene Wheel Material Energy Star Rated Can Be Used to Comply with:ASHRAE 62.2,California Title 24,and Washington State Energy Code Dimensional Quantity 1 Weight w/o Acc's(Ib) 17 Weight w/Acc's(Ib) 17 0.5 950 FRp� Performance 0.4 Requested Volume(CFM) 95 Actual Volume(CFM) 95 Total External SP(in.wg) 0.25 E 0.3 T Fan RPM 950 c r: a *FLA(A) 0.58 m a Elevation(ft) 108 Airstream Temp.(F) 70 ai 0.2 — T Air Density(Ib/ft3) 0.075 ocb Sones 0.6cn = - 0.1 8 -_ fi o Sqs�� 0.0 0 20 40 60 80 100 120 140 Motor Volume(CFM) Motor Mounted Yes 0 Operating point at Total External SP **Input Watts(W) 18 Fan curve -System curve Voltage/Cycle/Phase 115/60/1 Enclosure ODP Notes: All dimensions shown are in units of in. QmCQ *FLA is approximate and will vary slightly with the motor. WORLDWIDE Sones-calculated using AMCA 301 at 5 ft ORET ROH nl fED **Wattage is approximate and may vary between motors. fWAD Dn�to�ieRi mevEmmr romemiron ° mnnnnnonm. inc...9 Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 53 of 67 GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-P-1 Model: SP-A110 AMCA amca WORLDWIDE CERTIFIED RRTIRGS SOURD AAD AIR PERfORMAOCE AIR tp RIOYERIEAT wQi ARD COATROI .O-gc Rf1OCIRTIOn 7O... IATERAATIORAL. Inc. AMCA Licensed for Sound and Air Performance. Power Rating (Watt) includes transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Performance ratings include the effects of an inlet grille and backdraft damper. Speed (RPM)shown is nominal. Performance is based on actual speed of test. The watt ratings shown are at free air. The sound ratings shown are for loudness values in spherical sones at 5 ft. (1.5m) in a spherical free field calculated per Annex B of AMCA 311. Values shown are for installation type B: ducted outlet spherical sone levels. The AMCA Certified Ratings Seal applies to sone ratings only. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured Jobs 201R - -. _ _.. :. - ___ Page 54 of G7 Printed Date: 03/19/2019 igGREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B Model: SQ-120-B Direct Drive Centrifugal Inline Fan Dimensional _ Quantity I 1 Weight w/o Acc's(Ib) li 60 Weight w/Acc's(Ib) 107 Max T Motor Frame Size 56 Optional Damper(in.) 16 x 16 0.7 __ 0.35 /77> FRPM 0.6 ''_ 0.30 Performance Requested Volume(CFM) 1 1,000 0.5 0.25 Actual Volume(CFM) 1,000 Total External SP(in.wg) 0.38 '� C 0.4 m — ----- - 0.20 s Fan RPM 1117 — Operating Power(hp) 0.13 a 0. 0 Elevation(ft) 108 N 0 3 0.15 a Airstream Temp.(F) 70 ..= ---- Air Density(lb/ft3) 0.075 0.2 Qc 0.10 m Tip Speed(ft/min) 3,840 to \ Static Eff.(%) 17-2-1- -- o ) 40 1 .1 -_ -- ° - ' 0.05 O° S`Jke '_ . 0.0 - 0.00 0 2 4 6 8 10 12 14 Motor Volume(CFM)x 100 Motor Mounted Yes Size(hp) H 1/6 Voltage/Cycle/Phase 115/60/1 A Operating Bhp point Enclosure ODP 0 Operating point at Total External SP --- Fan curve Motor RPM 1140 -- - -System curve Windings 1 Brake horsepower curve Notes: All dimensions shown are in units of in. QmCQ *Please consult factory for actual motor amp draw WORLDWIDE Sound Power by Octave Band LwA-A weighted sound power level,based on ANSI S1.4 CERTIFIED dBA-A weighted sound pressure level,based on 11.5 dB RIITIRGf Soundattenuation per Octave band at 5 ft-dBA levels are not fOU11D Data 62.5 125 250 500 1000 2000 4000 8000 LwA dBA Sones licensed by AMCA International D Sones-calculated using AMCA 301 at 5 ft Inlet 63 65 66 64 56 53 49 42 64 53 6.1 PEREOR nO1 Radiated 65 67 61 58 51 47 43 39 59 48 4.6 AIR Rb4 MOVEOEAT 4. N. nssocinnon e IIITrROOTIOAAL.IfIG.' 9 Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 61 of 67 AlOGREEA1HECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B Model: SQ-120-B Direct Drive Centrifugal Inline Fan Standard Construction Features: -Galvanized steel housing-Backward inclined composite(sizes 60-95)or aluminum(sizes 100-160)wheel-Two bolted access panels-Integral duct connection flanges-Ball bearing motors(sizes 100-160 and all vari-green motors),sleeve bearing motors(sizes 60-95)-Corrosion resistant fasteners Selected Options &Accessories: PSC Motor UL/cUL 705 Listed-"Power Ventilators" Switch,NEMA-1,Toggle,Shipped with Unit Junction Box Mounted&Wired Damper Shipped Loose, Inline,VCD-23-OB-16X16, Not Coated Damper Actuator, 115 VAC Actuated Motor Cover Isolators&Brackets,Spring Hanging(1 Kit(s):Qty 4, PN:850344)(Shipped Loose) Solid State Speed Control,6 Amp,Shipped Loose Unit Warranty: 1 Yr(Standard) Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured.lobs 2018\G-L\Jaguar Land Rover.gfcj Page 62 of 67 IGREENHECK Printed Date: 03/19/2019 - Job: Jaguar Land Rover ® Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B SQ-120_B Direct Drive Centrifugal Inline Fan 22.75 O 0 EMNIMINIMli CIIMI NM 18.63 l t ) immommmi 3 0 TOP VIEW 15.88 SQ. INLET 19.00 ii I _ 1 1 1 J 19.00 i 1.50 — 21.00 — x-1.50 24.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 63 of 67 �GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B Disconnect Switch Enclosure Rating: NEMA-1 Standard Construction Features: Enclosure constructed for indoor use to provide a degree of protection to personnel against incidental contact with the enclosed equipment and to provide a degree of protection against falling dust. This enclosure meets the rod entry and the indoor corrosion protection design tests. The rod entry test is intended to simulate incidental contact with enclosure equipment. Enclosure is equipped with provision to lockout in the off position with customer supplied lock. Disconnect Switch Configuration Type: Toggle Motor Size: 1/6 hp Voltage: 115 UL Listed: Yes Manufacturer: Pass and Seymour Cycle: 60 Amperage: 15 CSA Approved: Yes Overload Protection: None Phase: 1 Switch Pole(s): 1 Rating: 1/2 hp Junction Box Mtg.: Mounted and Wired RPM: 1140 Exp. Resist. Wiring: None Switch Mounting: Shipped With Unit Electrical Drawing Details 00.28 (4 HOLES) Wiring Schematic I O 4.35 • n O • 1.06 • • )1 p 1.65 � 0.72 L.- 2.00 — 0I 1.06 2.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronC.r 1. , - -. .. I : IBGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B Assembly Drawing Type: Direct Drive Centrifugal Inline Fan 22.75 mmmommil coo �� 1 18.63 I � v. — ■O ti TOP VIEW } {I I I 15.88 SQ. INLET 19.00 III I 19.00 J 1.50 21.00 1.50 24.00 END VIEW SIDE VIEW Notes:All dimensions shown are in units of in.. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 65 of 67 GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B Control Damper Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications-Galvanized 16 ga channel frame-Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 5 in. and siz d - Fie wiring is required to individual components amper configuration: Actuator Type: 115 VAC End Switch: No 10.0 Min. 5.0� 110. 11A1P9 1111 16 1 16 1.3 max. y 1.3 max. DAMPER TYP. SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:1AaronCormack\Secured Jobs 2018\G-I\.ia0uar Land Rover.gfcj - Page-66-of-67— OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: EF-N-1 Inline Model: SQ-120-B AMCA amca WORLDWIDE CERTIFIED RRTIAGS SOURD RIR PERrORmnnCE nut mOVEAIEnT k; Anl)COATROI ASSOCIATIOA 0.04; IATERAATIOAAI. IAC. AMCA Licensed for Sound and Air Performance Without Appurtenances (Accessories). Power rating (BHP/kW)does not include transmission losses. Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. Performance certified is for installation type B: Free inlet, Ducted outlet. Power rating (BHP/kW)does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The inlet sound ratings shown are loudness values in fan sones at 5 ft. (1.5 m) in a hemispherical free field calculated per AMCA Standard 301. Values shown are for installation type B: free inlet hemispherical sone levels. dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to inlet sone ratings only. Radiated (casing)sound data is the sound generated through the fan housing when the fan is ducted on both the inlet and outlet. The AMCA licensed air and/or sound performance data has been modified for installation, appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but is provided to aid in selection and applications of the product. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 67 of 67 LGREENHEcK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: Elevator Relief Hood Model: FGR Model: FGR j'— A — — B Standard Construction Features: 1 } -Prestee ItArarill1111111 I! l construction.cisionformed -0.5locked in.rib galvanizedconstruction.steel mesh-Available birdscreens.inaluminum-Heavyorgalvanized gauge c galvanized steel support members. -Hood can be removed completely from the base or hinged open.-Units with a throat size exceeding 60 in.x 120 in.will have 11.11.1.111111111 Base Height 12 in.galvanized bases as standard.-Recommended roof opening dimension is iliMINNIIIIIIIIIIIIIIIMMIIMIN1 75 at least 2.5 in.larger than the damper size. F TVs -- — TL i T Curb Cap Width Curb Cap Length Dimensions Throat Throat Hood Hood I Hood Curb Cap Curb Cap Width Length Width Length Height Width Length Weight Ship ID# Tag Qty Model TW(in.) TL(in.) A(in.) B(in.) C(in.) (in.) (in.) (lb) Assembled 5-1 Elevator 1 FGR-24x24 24 24 34 36 19 30 30 108 Yes Relief Performance Throat Volume Throat Area Velocity ID# Tag Qty (CFM) SP(in.wg) (ft2) (ft/min) 5-1 Elevator 1 2,000 0.035 4 500 Relief Construction Installation Insect Base Birdscreen Unit ID# Type Screen Height(in.) Material Material 5-1 Ducted No 5 Galvanized Galvanized Accessories Texas Department of Florida Insurance Hood High Wind Product Miami-Dade Product Insulation Tie Down ID# Rated Approval# NOA# Evaluation Curb Seal (in.) Points 5-1 No N/A N/A N/A No 0.5 No Roof Curbs Height Width I Length Damper I j Insulation ------ .___ ID# Model (in.) (in.) (in.) Tray Material Thickness(in.) 5-1 GPI 12 1 30 30 No Galvanized 1 Dampers Width Length Blade Frame Actuator Actuator Actuator End Damper ID# Model (in.) (in.) Action Type Type Quantity Mounting Switch Mounting 5-1 VCD-23 24 24 Parallel Channel 115 VAC 1 Internal No Ship Separate Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y\AarmnCormack\Secuued Jobs 20 --L\Jaguar--6and Rover.gfcj Page 55 of 67 • flI GREEAIHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: Elevator Relief Hood Model: FGR Roof Curb Line Number: 5-1 Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum -Straight Sided without a cant-2 in. mounting flange- 3 lb density insulation - Height -Available from 12 in.to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. - Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 28.55 28.55 12.00 1144 /1 32.50 32.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 56 of 67 �GREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: Elevator Relief Hood Model: FGR Control Damper Line Number: 5-1 Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications- Galvanized 16 ga channel frame-Galvanized blades with reinforcements-Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No 1.3 ` max. 2` 24 II f 1 10.0 } 19% AX I, 5.0 Min. 1.3 A max. DAMPER TYP.SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y\Aaroncormark\Secured!obs 2018\G—Ja-Land • Printed Date: 03/19/2019 thrGREENHECK Job: Jaguar Land Rover Building Value in Air. Mark: LV-C-1 (Revised-Intake Hood) Model: FGI Model: FGI A B Standard Construction Features: 1111 1 -Precision formed locked rib construction. -Available in aluminum or galvanized 1 steel construction. -0.5 in.galvanized steel mesh birdscreens. -Heavy gauge-1—Miiil , galvanized steel support members. -Hood can be removed completely from the jbase or hinged open.-Units with a throat size exceeding 60 in.x 120 in.will have I Base Height } 12 in.galvanized bases as standard.-Recommended roof opening dimension is IIIME 11111.111111111111__:11.15 1 at least 2.5 in.larger than the damper size. ,'J. .-.- TL Curb Cap Mat Curb Cap Length Dimensions Throat Throat Hood Hood Hood Curb Cap Curb Cap Width Length Width Length Height Width Length Weight Ship ID# Tag Qty Model TW(in.) TL(in.) A(in.) B(in.) C(in.) (in.) (in.) (Ib) Assembled 6-1 LV-C-1 1 FGI-30x30 30 30 56 48 19 36 36 155 Yes Performance Throat Volume Throat Area Velocity ID# Tag Qty (CFM) SP(in.wg) (ft2) (ft/min) 6-1 LV-C-1 1 3,400 0.039 6.25 544 Construction Installation Insect Base Birdscreen Unit ID# Type Screen Height(in.) Material Material 6-1 Ducted No 5 Galvanized Galvanized Accessories 1 Texas Department of Florida Insurance Hood Supply High Wind Product Miami-Dade Product Insulation Tie Down ID# Filters Rated Approval# 1 NOA# I Evaluation Curb Seal (in.) Points 6-1 No No N/A I N/A N/A I No 1 0.5 No Roof Curbs Height Width Length Damper Insulation ID# Model (in.) (in.) (in.) Tray Material Thickness(in.) 6-1 GPI 12 36 36 No Galvanized 1 Dampers Width Length Blade Frame Actuator Actuator Actuator End Damper ID# Model (in.) (in.) Action Type Type Quantity Mounting Switch Mounting 6-1 VCD-23 30 30 Parallel Channel 115 VAC 1 Internal No Ship Separate Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 58 of 67 OGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: LV-C-1 (Revised-Intake Hood) Model: FGI Roof Curb Line Number: 6-1 Model: GPI Material: Galvanized Standard Construction Features: - Roof Curb fits between the building roof and the fan mounted directly to the roof support structure -Constructed of either 18 ga galvanized steel or 0.064 in. aluminum-Straight Sided without a cant-2 in. mounting flange-3 lb density insulation - Height -Available from 12 in. to 42 in. as specified in 0.5 in. increments. Notes: -The maximum roof opening dimension should not be greater than the "Actual"top outside dimension minus 2 in.. -The minimum roof opening dimension should be at least 2.5 in. more than the damper dimension or recommended duct size. -The Roof Opening Dimension may or may not be the same as the Structural Opening Dimension. - Damper Tray is optional and must be specified. Tray size is same as damper size. -Security bars are optional and must be specified. Frames and gridwork are all 12 ga steel. Gridwork is welded to the frame and the frame is welded to the curb. 34.55 34.55 12.00 0 38.50 38.50 Notes:All dimensions shown are in units of in. Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:WaronCormack\Secured,hbs 2018\V-L\Jaguar Land Rovcr.gfcj Paye 59 of 87 ffIGREENHECK Printed Date: 03/19/2019 Job: Jaguar Land Rover Building Value in Air. Mark: LV-C-1 (Revised-Intake Hood) Model: FGI Control Damper Line Number: 6-1 Model: VCD-23 Standard Construction Features: - Model VCD-23 is a well built low leakage control damper for automatic control or manual balancing applications- Galvanized 16 ga channel frame-Galvanized blades with reinforcements- Side mounted steel linkage is concealed in the frame to prevent additional pressure drop-Axles are steel and 0.5 in. dia.-Synthetic axle bearings-Width and height furnished approximately 0.25 in. undersized - Field wiring is required to individual components Damper Configuration: Actuator Type: 115 VAC End Switch: No f I `30 � max. ft 10.0 30 + 5.0 Min. 1.3 A max. DAMPER TYP.SECTION VIEW Notes:All dimensions shown are in units of in. Width And height furnished approximately 0.25 in.undersize Generated by:jfisher@johnsonair.com CAPS 4.28.1746 Y:\AaronCormack\Secured Jobs 2018\G-L\Jaguar Land Rover.gfcj Page 60 of 67