Report (32)
C0717?5QA0-1/4- COI\ OPPle Gas Fired Unit Heater Schedule Ext. Line Reznor MBH Fuel Fan SP Voltage& No. Qty Unit Tags Model-Size Output Type HP RPM CFM "WC Phase Unit Notes 1 1 UH-C-1 UDAP-30 24.6 .02 1550 456 0 2 1 UH-C-2 UDAP-30 24.6 .02 1550 456 0 3 1 UH-C-3 UDAP-30 24.6 .02 1550 456 0 4 1 UH-C-4 UDAP-30 24.6 .02 1550 456 0 5 1 UD-N-1 UDAP-45 37.35 .03 1550 629 0 6 1 UH-N-2 UDAP-45 37.35 .03 1550 629 0 Unit Notes: 1) 2) 3) 4) 5) Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UH-C-1 UDAP-30 high efficiency (82-83%) power vented propeller unit heater, multitry spark ignition w/lockout, 115/1, 24v ctrls f. AA1 Natural Gas AG1 One Stage Operation . The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being offered for this submittal. Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UH-C-2 UDAP-30 high efficiency (82-83%)power vented propeller unit heater, multitry spark ignition w/lockout, 115/1, 24v ctrls AA1 Natural Gas AG1 One Stage Operation The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being o`fered for this submittal. Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UH-C-3 (JDAP-30 high efficiency(82-83%)power vented propeller unit heater, muititry spark ignition w/lockout, 115/1, 24v ctrls AAI. Natural Gas AG1 One Stage Operation The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being offered for this submittal. Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UH-C-4 UDAP-30 high efficiency(82-83%)power vented propeller unit heater, multitry spark ignition w/lockout, 115/1, 24v ctris AA1 Natural Gas AG1 One Stage Operation The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being o fered for this submittal. Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UD-N-1 "DAP-A high efficiency (82-83%)power vented propeller unit heater, multitry spark ignition w/lockout, 115/1, 24v ctrls AA1 Natural Gas AGI. One Stage Operation The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being offered for this submittal. Date: 9/18/2018 Job Name: JAGUAR LAND ROVER Location: Portland, OR Unit Tag: UH-N-2 UDAP-45 high efficiency(82-83%)power vented propeller unit heater, multiary spark ignition w/lockout, 115/1, 24v ctrls AA1 Natural Gas AG1 One Stage Operation The bill of material above is all that is being submitted for acceptance.Supporting pages attached may have other options not included in the listing above.They are not being offered for this submittal. • Included Options AA1: Unit equipped for natural gas Natural gas is a naturally occurring gas mixture consisting primarily of methane and includes varying volumes of alkanes, carbon dioxide, nitrogen, and hydrogen sulfide. 1 Therm = 100,000 BTU = 29.3 kWh AG1: Gas controls designed for recirculating air heating application. Furnace has a 24 volt, single stage combination gas valve which includes the electronic on-off valve controlled by a single-stage 24 volt room thermostat, a pressure regulator, a safety pilot valve, and the manual shutoff valve. MODEL(S) UDAP A -UDAP 030 -UDAP 045 11 is 1 171 W. 4 16 5 I t t 9 I" 8"-16 FEMALE THREAD • 13 I -ALL SUSPENSION POINTS 1 1I T -- 1 l- 2i 26 ,,ii- 21i OMTION AIR INLET e e s� mels1�1. '-~ THERMOSTAT Ir1+ • ~ CONNECTION VD 1).44, /� 121 10 r ,i ii 1��V _ '. ,:•••:::;•; .. ��!= 8 i ACCESS PANEL %%%�� ������ r 5-11 1 21r Aon LINE VOLTAGE INLET 38 VENTA CONNECTION (CONNECTS AT NOTES: CIRCUIT BOARD) 61 XTERNAL GAS 2 CONNECTION SIZE SHOWN IS FOR GAS CONNECTION TO A SINGLE STAGE GAS VALVE.NOT SUPPLY LINE SIZE. DIA 2" *17-3/8"AND 11/16--HANGER DIMENSIONS FOR BOTH 2-PT AND 4-PT SUSPENSION. '4-5/16"AND 13"-HANGER DIMENSIONS FOR 4-PT SUSPENSION. "9-9/16"-HANGER DIMENSION FOR 2-PT SUSPENSION. ALL DIMENSIONS ARE IN INCHES Page of REZNO ® '' - Model U DAP Power Vented, Low Static Axial Fan Unit Heaters for € esidential and Commercial/Industrial Use Sizes 30-125 approved for utility applications such as residential garages under CSA International Requirement 10.96-U.S.and CR96-0005-Canada N 0 STANDARD FEATURES itt t Sizes 30-125 certified for residential heating application •Sizes 30-400 certified for commercial/industrial heating application •82-83%Thermal efficient—TOP in ifs class! •50-60°F Rise range NEWTcoRE2®titanium stabilized aluminized steel heat exchanger •NEW patented**TcoRE2®single burner combustion system including a one- ,00 9oc .yK� ,. .0412'1:4* piece burner assembly • ! PQs 05. • 115/1/60 Supply voltage ��� Lal, ! i • `�� • 115 Volt open fan motor with internal overload protection ml • Feta all k"rs+y Transformer for 24-volt controls CSA 2.6b ANSI Z83.8b •Integrated circuit board with diagnostic indicator lights •Multi-try direct spark ignition with 100%lockout DESCRIPTION •Fan relay(included on the circuit board) *Single-stage natural gas valve(field adjustable for operation to 9,000 ft Reznor®V 3 Series Model UDAP gas-fired unit heat- elevation) ers are available in 14 sizes ranging from 30,000 to •Vibration/noise isolated fan and venter motors- 400,000 BTUH gas input. Sizes 30-125 are approved designed for low noise operation for residential application.All sizes are approved for com •2-pt and 4-pt Suspension-standard on all sizes mercial/industrial installations.Model UDAP heaters are •External terminal strip for 24-volt wiring designed for 82-83%thermal efficiency and are approved conne gas c External tion for installation in the United States and Canada by the •Full•Exterrfan guard-engineered for safety Canadian Standards Association(CSA). Ap Improved cabinet design with less visible hardware and a NEW Reznor Reznor®' 3 Series unit heaters have a refreshing new appearance appearance with a glossy white cabinet finish and less visible hardware.Each size cabinet is easily suspended OPTIONAL FEATURES -FACTORY INSTALLED from either 2 or 4 suspension points. Or, an optional •Single-stage,propane gas valve(field adjustable for operation to 9,000 ft hanger kit for Sizes 30-125 allows for ceiling mounting. elevation) The low voltage terminal strip on the outside of the cabi- •Two-stage natural gas or propane gas valve-Sizes 60-400 net makes connecting control wiring easy with no pan- •409 or 316 Stainless steel heat exchangers els to remove.The addition of a"G"terminal to the strip, •208 or 230 Single phase voltage along with the new design of the circuit board,allows for •Totally enclosed fan motor(Sizes 30-250,115V only) fan only operation(without adding relays).All units have •.Common venting with other gravity vented Category I appliance(s)(Sizes a factory installed gas-tine nipple to the exterior of the 30-100) cabinet for easy gas service connection. CCF , OF I o FIELD INSTALLED The preeminent new internal feature is the TCORE2 heat exchanger and single burner combustion system. •Vent cap Other standard features include a single-stage gas valve, S Thermostat multi-try direct spark ignition with 100% lockout, pres- •Thermostat guard with locking cover sure switch to verify vent flow,resiliently isolated venter :•Vertical louvers-new design motor, venter wheel with improved housing, resiliently •Downturn nozzle kits--new design isolated axial fan and motor assembly,and a high tern- • Gas conversion kits(natural and propane) perature limit control.Sizes 30-125 also include a flame •Master/Slave controls for zoning up to six units rollout safety switch.Operation is controlled through an •Ceiling suspension kit-Sizes 30-125 integrated circuit board.The circuit board monitors heater • Hanger kits for 1"pipe operation and has LED diagnostic indicator lights to Iden- •Stepdown transformer(for 230/3 and 460/3 supply voltage) tify abnormalities in control functions. • Manual shutoff valves The new VI Series unit heaters are designed to pro- vide all the features you expect in a Reznor heater plus improved efficiency, easier installation, and a new look both inside and out. U.S.Patent No.6,889,686 Form RZ-NA-C-UH Page 6 S Page of MODEL UDAP TECHNICAL DATA-Sizes 30-125 Size 30 45 60 75 100 125 Input Heating Capacity BTUH ` 30,000 45,000 60,000 75,000 105,000 120,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 "CSA rating for altitudes Thermal Efficiency(%) 82 83 83 83 83 83 to 2000 ft. Output Heating Capacity" BTUH 24,600 37,350 49,800 62,250 87,150 99,600 'Size shown is for gas kw/h 7.2 _ 11.0 14.6 18.3 25.6 P9.2- connection to a single E Natural a 1/2 1/2 1/2 1/2 1/2 1/2 stage gas valve, not Gas Connection(inches) supply line size. Propane 1/2 1/2 1/2 1/2 1/2 1/2 Vent Connection Size°(inches diameter) 4 4 4 4 4 4 'Smaller or larger vent pipe diameters maybe Control Amps(24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 allowed; refer to the Full Load Amps(115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 Venting Installation Maximum Over Current Protection(115 15 15 15 15 15 15 Manual,Form I-V-PV.If Normal Power Consumption(watts) r 109 155 155 217 276 354 vent diameter is differ- Discharge Air Temperature Rise(°F) r 50 55 60 60 60 60 ent from vent connec- t- tion,456 629 769 961 1345 1537 tion,reducer/enlargers Air Volume will be field-required. M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 DMODP =2.25 x(larg- ft2Discharge Air Opening Area 0.96 0.96 1.25 1.25 2.01 2.01 est motor FLA)+small- M2 0.09 0.09 0.12 0.12 0.19 0.19 est motor FLA.Answer Output Velocity FPM 475 656 616 770 668 763 is rounded to the near- M/minute 145 200 188 238 196 245 est commercially avail- Fan Motor HPE Open + 0.02 0.03 0.03 0.06 1/30 1/20 able circuit breaker. Enclosed 0.06 0.06 _ 0.06 0.06 1/4 1/4 'All other information in Fan Motor RPM 1550 1550 1550 1550 1050 1050 this table is based on Fan Diameter(inches) 1 10 10 12 12 16 16 a heater equipped with Sound Level dba @ 15 40 40 40 49 54 55 a standard 115 volt lbs 54 59 67 72 96 101 open fan motor. Approximate Net Weight E kg i 24 27 v 30 33 44 46 Approximate Ship Weight lbs 61 66 74 79 118 123 kg 27 30 33 36 54 56 MODEL UDAP TECHNICAL DATA Lea J Uu-WU Size 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency(%) 83 83 83 83 83 83 83 83 BTUH 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 Output Heating CapacityA kw/h 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection(inches)a Natural 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Propane 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size c(inches diameter) 5 5 5 5 5 6 6 6 Control Am ps(24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps(115 volt) 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection(115V)° 15 15 15 15 15 20 20 20 Normal Power Consumption(watts) 392 392 491 747 747 1086 1086 1086 Discharge Air Temperature Rise(°F) 60 60 60 60 60 60 60 60 Air Volume CFM 1921 2242 2562 2882 3202 3843 4483 5123 M3/minute 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening Area ft2 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 M2 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 752 877 1003 820 911 802 936 1069 M/minute 229 267 306 250 278 244 285 326 Fan Motor HP E Open 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 1/4 1/4 1/4 1/4 1/4 1/2 1/2 1/2 Fan Motor RPM 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter(inches) 18 18 18 20 20 24 24 24 Sound Level dba©15 ft 51 52 53 56 56 59 61 62 Approximate Net Weight lbs 172 187 187 203 215 269 294 306 kg 78 85 85 92 98 122 133 139 Approximate Ship Weight lbs 204 219 219 245 257 321 346 358 kg 93 100 100 111 117 146 157 163 Form RZ-NA-C-UH Page 7 I Page of Model UDAP - GENERAL ARRANGEMENT AND DIMENSIONS N--- . M ■ R-Hanger ., Dimension for i - 2-pt Suspension •11 Combustion P Air Inlet -4r P and Q R • Thermostat REARu \' Hanger Connection .' VIEW ', Dimensions TOP VIEW �� � �� �- ,. (30-125 Vertical; � - for 4-pt 150-400 Horizontal) Suspension Q AlibiAlibi .(.. rr � a.zf71 i 3/8"-16 Female Thread i v„ii ii:40r�T1' 3 - all suspension points • Line Voltage J - K External Vent Connection Inlet(connects < H— Gas (see Technical at circuit board) Connection Data for size) l& B c E D L F `h�� __ _ FRONT RIGHT SIDE VIEW II . �II 0(Access Panel) 'I' A CI :::4;:,I _ N Form RZ-NA-C-UH Page 8 Page _ of Mode! MDA - GENERAL ARRANGEMENT AND DIMENSIONS (cont'd) MODEL UDAP DIMENSIONS (± 1/16") Size A B C D E F G H J K M N P Q R 30,45 12-1/8 26-5/8 10 13-13/16 26 21-9/16 5-3/16 6-1/2 2-11/16 3-7/8 17-3/8 11/16 4-5/16 13 9-9/16 co 1C 1/0 CC C/o 13 10 13/1C C7 C1 0/1C 7 /0 C 1/C C 1/C 3 7/0 17 3/0 11/1C 1 C/iC 10 10 1/C 75 15-1/8 26-5/8 13 13-13/16 27-5/8 21-9/16 7-7/8 6-1/2 5-1/2 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 100 23-1/8 26-5/8 21 13-13/16 28-5/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 125 23-1/8 26-5/8 21 13-13/16 29-3/8 21-9/16 14-1/2 6-1/2 8-3/4 3-7/8 17-3/8 11/16 4-5/16 13 10-1/2 150, 175, 20-1/8 38-3/16 16 23 42 35-3/8 8-1/2 8-1/4 5-7/16 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 16-3/8 200 225' 26-1/8 38-3/16 22 23 42 35-3/8 13-1/16 8-13/16 9 6-1/2 25-11/16 1-3/8 8-3/16 22-3/16 15-5/8 250 300, 350, 34-1/8 41 30 23 42 35-3/8 17-1/16 9 11-13/16 7-5/16 27-11/16 1-3/8 8-3/16 22-3/16 16-3/16 400 MODEL UDAP DIMENSIONS (±2mm) Size A B C D E F G H J K M N P Q R 30,45 308 676 254 351 660 548 132 165 68 98 441 17 110 330 243 60 384 676 330 351 686 548 200 165 140 98 441 17 110 330 267 75 384 676 330 351 702 548 200 165 140 98 441 17 110 330 267 100 587 676 533 351 727 548 368 165 222 98 441 17 110 330 267 125 587 676 533 351 746 548 368 165 222 98 441 17 110 330 267 150, 175, 511 970 406 584 1067 899 216 210 138 165 652 35 208 564 416 200 225' 664 970 559 584 1067 899 332 224 229 165 652 35 208 564 397 250 300, 350, 867 1041 762 584 1067 899 433 229 300 186 703 35 208 564 411 400 CLEARANCES Size Top Flue Connector Access Panel Non-Access Side Bottom* Rear inches mm inches mm inches nm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 4 25 1 25 18 457 I *Suspend the heater so that the bottom is a minimum of 5'(1.5M)above the floor. Form RZ-NA-C-UH Page 9