Plans (144) GENERAL NOTES AERIAL VIEW CODES AND STANDARDS -— 1. ALL WORK SHALL COMPLY WITH 2017 OREGON ELECTRICAL CODE(OEC),2017 OREGON RESIDENTIAL SPECIALTY CODE(ORSC),AND ALL STATE AND LOCAL BUILDING AND � � ELECTRICAL CODES. LIABILITY '= 2 DRAWINGS HAVE BEEN DETAILED ACCORDING TO UL LISTING REQUIREMENTS. The City of Tigard and its _ %� tVr MAY 2 8 2019 1220 S.630E STE.430 employees shall not be e� �-, -:... ' , CITY OF TIG TIGARD 5 AMERICAN FORK,UT 84003 responsible for discrepancies = _ �0 6J i rlFzrvf which may appear herein. + '3UILDING DIVISION! 800-377-4480 WWW.BLUERAVENSOLAR COM SITE NOTES/OSHA REGULATION y - 1. A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH OSHA REGULATIONS. "z CONFIDENTIAL-THE INFORMATION 2. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS AN UTILITY - 1 HEREIN CONTAINED SHALL NOT BE INTERACTIVE SYSTEM WITH NO STORAGE BATTERIES. - USED FOR THE BENEFIT OF VA��D�TY �� PERMI� ANYONE EXCEPT 3. THE SOLAR PV INSTALLATION SHALL NOT OBSTRUCT ANY PLUMBING,MECHANICAL,OR f�11��YY�� =' i BLUERAVENSOLAR NOR SHALL IT BUILDING ROOF VENTS. r � OFFICE COPY 4. ROOF COVERINGS SHALL BE DESIGNED,INSTALLED,AND MAINTAINED IN ACCORDANCE WITH THE ISSUANCE OF A PERMIT • „, BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE THIS CODE AND THE APPROVED MANUFACTURER'S INSTRUCTIONS SUCH THAT THE ROOF BASED ON CONSTRUCTION e - RECIPIENTS ORGANIZATION, COVERING SHALL SERVE TO PROTECT THE BUILDING OR STRUCTURE. DOCUMENTS AND OTHER EXCEPT IN CONNEC TION WITH THE � SALE AND USE OF THE RESPECTIVE DATA SHALL NOT PREVENT ' EQUIPMENT,WITHOUT THE SOLAR CONTRACTOR . WRITTEN PERMISSION OF THE CODE 01=FICIAL FROM BLUERAVENSOLAR LLC. 1. MODULE CERTIFICATIONS WILL INCLUDE UL1703,IEC61646,IEC61730. REQUIRING THE CORRECTION t � 2. IF APPLICABLE,MODULE GROUNDING LUGS MUST BE INSTALLED AT THE MARKED GROUNDING RS(r` �Qrj,�} a► ;- OF ERRORS.O C E P LUG HOLES PER THE MANUFACTURERS'INSTALLATION REQUIREMENTS- f 1 3. AS INDICATED BY DESIGN,OTHER NRTL LISTED MODULE GROUNDING DEVICES MAY BE USED ' f" -11. 4 =- IN PLACE OF STANDARD GROUNDING LUGS AS SHOWN IN MANUFACTURER DOCUMENTATION CERTIFIED AND APPROVED BYTHEAHJ. > "-c / PV INSTALLATION 4. CONDUIT AND WIRE SPECIFICATIONS ARE BASED ON MINIMUM CODE REQUIREMENTS AND pp ,y * � ARE NOT MEANT TO LIMIT UP-SIZING AS REQUIRED BY FIELD CONDITIONS. �t • �DVP'u plans '''- o i �' PROFESSIONAL 5. CONDUIT POINT OF PENETRATION FROM EXTERIOR TO INTERIOR TO BE INSTALLED AND shall be on job sqs,.. Scott Gurney . - R v,�,a�� ,,,��,. ,,,,, a 4 P V-01 1 71 9-01 5866 rter SEALED WITH A SUITABLE SEALING COMPOUND // 6. DC WIRING LIMITED TO MODULE FOOTPRINT W/ENPHASE AC SYSTEM. xr."` CONTRACTOR: 7. ENPHASE WIRING SYSTEMS SHALL BE LOCATED AND SECURED UNDER THE ARRAY W/ t � T & BRS FIELD OPS SUITABLE WIRING CLIPS. .w...-,�"z` ° . '�� 385.498.6700 8. MAX DC VOLTAGE CALCULATED USING MANUFACTURER PROVIDED TEMP COEFFICIENT FOR ` VOC UNLESS NOT AVAILABLE. 9. ALL INVERTERS,MOTOR GENERATORS,PHOTOVOLTAIC MODULES, PHOTOVOLTAIC PANELS, - �' � ' 12,x. N AC PHOTOVOLTAIC MODULES,DC COMBINERS,DC-TO-DC CONVERTERS,SOURCE CIRCUIT . r ,, COMBINERS,AND CHARGE CONTROLLERS INTENDED FOR USE IN A PHOTOVOLTAIC POWER SYSTEM WILL BE IDENTIFIED AND LISTED FOR THE APPLICATION PER 690.4(B). --1,-,...,,t-,„;:,:iI -5 0 a 10. ALL SIGNAGE TO BE PLACED IN ACCORDANCE WITH LOCAL BUILDING CODE. :I4. % ,--:- $: C EQUIPMENT LOCATIONS F "` 1. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED zCO .,�` 7 a E o ELECTRICAL EQUIPMENT WILL BE PROVIDED AS PER SECTION[NEC 110.26]. i7-7,7.1f, -,-„i.7.,;,;.,,,,.-r-- (B V 2. EQUIPMENT INSTALLED IN DIRECT SUNLIGHT MUST BE RATED FOR EXPECTED OPERATING � ® �" "�` "� �' """' - -- -- - Z � � CV � TEMPERATURE AS SPECIFIED BY[NEC 690.31 (A)-(B)j AND[NEC TABLE 310.15(B)]. DESIGN CRITERIA SITE SPECIFICATIONS SHEET INDEX Om 0) N 3. ADDITIONAL AC DISCONNECTS SHALL BE PROVIDED WHERE THE INVERTER IS NOT ADJACENT H 'L7... ASCE 7 WIND SPEED: 110 MPH OCCUPANCY - R3 PV1 - COVER SHEET TO THE UTILITY AC DISCONNECT,OR NOT WITHIN SIGHT OF THE UTILITY AC DISCONNECT. < U O 4. ALL EQUIPMENT SHALL BE INSTALLED ACCESSIBLE TO QUALIFIED PERSONNEL ACCORDING GROUND SNOW LOAD: 10 PSF CONSTRUCTION - V-B PV2 - PROPERTY PLAN TO NEC APPLICABLE CODES. EXPOSURE CATEGORY: C ZONING: RESIDENTIAL PV3 - SITE PLAN o5 15 0) w 5. ALL COMPONENTS ARE LISTED FOR THEIR PURPOSE AND RATED FOR OUTDOOR USAGE LL O 0 H WHEN APPROPRIATE SEISMIC DESIGN CATEGORY: D PV4 - EQUIPMENT &ATTACHMENT DETAIL Z CL (J) (n PV5 - ELECTRICAL SINGLE LINE DIAGRAM — ° o 0 >- SCOPE OF WORK PV6 - ELECTRICAL CALCULATIONS & I- 0) U CITY OF TIGARD ELECTRICAL NOTES v) U , i— a REVIEWED FOR DE COMPLIANCE INSTALLATION OF UTILITY INTERACTIVE PHOTOVOLTAIC SOLAR SYSTEM PV7 - MAIN BREAKER DERATE CALCS. DRAWING BY (IF NEEDED) Kate Petersen Approved: [Vi 8.06 kW DC PHOTOVOLTAIC SOLAR ARRAY PV8 - LABELS & LOCATIONS OTC: [ ] ROOF TYPE: Comp Shingle PV9 - STRING & SE OPTIMIZER DATE Permit#•. It \,S—r - t' — d D 1 1 S MODULES: (26) JinKO Solar Eagle JKM 310M-60L PV10 - CUSTOM DIRECTORY PLACARD May 9, 2019 Address: 1314 0 SVP g ta-L-k..- \/3CA►1`"J V5> INVERTER(S): Enphase IQ7-60-2-US,---- (IF NEEDED - NEC 690.56(B)) PROJECT NUMBER RACKING: Unirac Sunframe Microrail 61338165 Suite #: By: Piii)c- Date: 5/-2A ( 1 SHEET NAME 111 COVER SHEET PAGE NUMBER REVISION PV1 0 LEGEND INV INVERTER&DC DISCONNECT RAVEN 13140 Southwest Black Walnut SUB (E) SUBPANEL Street LC (N) LOAD CENTER 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT N BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN FRONT OF HOME C COMBINER BOX PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE PV PV REVENUE METER SALE AND USE OF THE RESPECTIVE EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF (7.4. BLUERAVENSOLARLLC. FIRE SETBACK IM , EMT CONDUIT RUN p (TO BE DETERMINED IN FIELD) Np C P CERTIFIED PV WIRE STRING PV INSTALLATION ©MI °° ° I PROFESSIONAL 0 I PROPERTY LINE Scott Gurney 111 #PV-011719-015866 0 SCALE: 1/16"= 1'-0" CONTRACTOR: 0 4' 0 16 32• BRS FIELD OPS 385.498.6700 108'-1" isio El. II. Sic 0) 61. 0 1.020 go U ° E c gc E Y O Z (RI) CD .1- 00 MP1 O L m rn N #OF MODULES: 26 2 0 C AZIMUTH:179° _c m W _ PITCH:24° O -c 0 I- TSRF:75% Z o O CO AREA: 826 SQ. FT w L •:1- c13 co H 0 ROOF ATTACHMENTS SHALL BE SPACED U) U 1- NO GREATER THAN 24" ON CENTER IN DRAWING BY ANY DIRECTION WHERE LOCATED Kate Petersen WITHIN 3' OF A ROOF EDGE, HIP, EAVE, OR RIDGE OSSC 3111.5.3 ITEM 3.2 DATE 55'-3" May 9, 2019 PROJECT NUMBER DC SYSTEM SIZE: 8.06 kW DC 61338165 ROOF TYPE: Comp Shingle SHEET NAME (26) JinKO Solar Eagle JKM 310M-60L PROPERTY PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV2 0 LEGEND INV INVERTER&DC DISCONNECT NSUB (E) SUBPANEL FRONT OF HOMEICk LC (N) LOAD CENTER 1220 S 630E STE 430 AMERICAN FORK,UT 84003 AC AC DISCONNECT 800-377-4480 WWW.BLUERAVENSOLAR.COM M UTILITY METER/SERVICE PANEL CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF JB JUNCTION BOX ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN C COMBINER BOX PART TO OTHERS OUTSIDE RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE PV PV REVENUE METER SALE AND USE OF THE RESPECTIVE 8 PV REVENUE METER EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF VA FIRE SETBACK BLUERAVENSOLAR LLC EMT CONDUIT RUN g (TO BE DETERMINED IN FIELD) ACE(` CERTIFIED PV WIRE STRING PV INSTALLATION I PROFESSIONAL I Scott Gurney M MSP PROPERTY LINE #PV-011719-015866 O I 0 O CONTRACTOR: O SCALE: 1!8"= 1'-0" AC 4 BRS FIELD OPS 385.498.6700 C m 0) L O (75 _ U so c — ////K1///_z(///�/// ////�/// (//( (///(/j E o (0 1' I I as U 00 Z W (3 N ffc ffc Pic Pfc &fc O m N JB t— .L N Q U N c [lc ffc Ilc Pic M P 1 2 S o LL_ L0) 2 0 # OF MODULES: 26 O m 5 a2 LU � LL -� o I— L c Q L c ffc AZIMUTH:179 Q u O H 22 11 Z o PITCH:24° — o -2- >- o W L dU) Sic IT ffc Lfc Ilc TSRF:75% I— .- 0 AREA: 826 SQ. FT U — H p ffc 0 &C ffc [lc DRAWING BY Kate Petersen L&fc ffc ffc ffc ffc / DATE / May 9, 2019 PROJECT NUMBER DC SYSTEM SIZE: 8.06 kW DC - 3' 61338165 ROOF TYPE: Comp Shingle 36'-1" SHEET NAME (26) JinKO Solar Eagle JKM 310M-60L SITE PLAN Enphase IQ7-60-2-US,----INVERTER PAGE NUMBER REVISION PV3 0 ROOF ATTACHMENTS SHALL BE SPACED PV MODULE(BEHIND TRIM RAIL) Unirac Sunframe Microrail TRIM RAIL NO GREATER THAN 24" ON CENTER IN PV ARRAY INFORMATION ANY DIRECTION WHERE LOCATED WITHIN 3' OFA ROOF EDGE, HIP, EAVE, �, LANDSCAPE BLUE RAVEN PV MODULE COUNT: 26 MODULES OR RIDGE OSSC 3111.5.3 ITEM 3.2 jr E g pg g El t #OF ATTACHMENT POINTS: 88 —M 48" MAX. ARRAY AREA: Module Count x 17.51 ft2=455.3ft2 I 1220 S.630E STE.430 ROOF AREA: 1677.Oft2 AMERICAN FORK,UT 84003 PORTRAIT % OF ARRAY/ROOF: 27.1% jr 1 11" 111 El R El PI I 800-377-4480 WWW.BLUERAVENSOLAR.COM ARRAY WEIGHT: Module Count x 50Ibs = 1300.OIbs —MAX. 48" MAX. ARRAY DETAIL, FRONT VIEW CONFIDENTIAL-THE INFORMATION DISTRIBUTED LOAD: Array Weight=Array Area = 2.86 lbs/ft2 SFM Raised Seal Flashing HEREIN CONTAINED SHALL NOT BE Scale: 3/8"= 1'-0" USED FOR THE BENEFIT OF POINT LOAD: Array Weight_Attachments = 14.8Ibs/attachment ANYONE EXCEPT RACKING ATTACHMENTS TO BE Unirac Sunframe Microrail FRAME BLUERAVENSOLAR NOR SHALL IT STAGGERED BY SHIFTING EACH BEE DISCLOSED IN WHOLE OR IN SUBSEQUENT ROW OF ATTACHMENTS . PORTRAIT PART TO OTHERS OUTSIDE ONE RAFTER OVER. RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE ® SALE AND USE OF THE RESPECTIVE �� �'� EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF c� BLUERAVENSOLARLLC. Unirac Sunframe Microrail / UNIRAC TRIMRAIL �. MODULE '/" LANDSCAPE / WIDTH �i / A (1 JinKO Solar Eagle JKM 310M-60L CERTIFIED _®e _.. _. ._ PV MODULE " ARRAY DETAIL, SIDE VIEW PV INSTALLATION 0 \ .�' 24 PROFESSIONAL z 1 (E) ROOF cScale: 3/8" = 1'-0' Scott Gurney Q - r?.--- MEMBRANE /f #PV-011719-015866 o OW. ■i MODULE 2.5" CONTRACTOR: O II J a Oo ° _ UNIRAC SLIDERS AND WIDTH 1— M TRIMRAIL ROOF ATTACHMENTS BRS FIELD OPS 385.498.6700 F— O 6 m - FLASHING } J 2.5" MIN. EMBED. N Q 1 1 ROOF TYPE: Comp Shingle I- 5/16"STAINLESS STEEL LAG BOLT U in p WITH 2-1/2" MIN. EMBEDMENT ROOF FRAMING TYPE: Manufactured Truss AND FLAT WASHER c�� C� - (E) BUILDING RAFTER OR TOP CHORD(TRUSS)2x4 @ 24"O.C. rti STRUCTURE CEILING JOIST OR BOTTOM CHORD(TRUSS)2x4 @ 24"O.C. E > o0 Z (n •c3 N °o O N L m rn N Unirac Sunframe Microrail 12 U a) O LLQ N 5 N W 00 JinKO Solar Eagle JKM 310M-60L Z - Cl) - C PV MODULE — O >' M U) U c— I— 0 t O _ '1 (E) ROOF DRAWING BY 2.5" MEMBRANE Kate Petersen 11 w n — J - O &.) — I 0 °� _� UNIRAC SLIDERS DATE May9, 2019 U J 2.5" MIN. EMBED. Q ` PROJECT NUMBER FLASHING 61338165 I— W 0 5/16" STAINLESS STEEL LAG BOLT WITH 2-1/2" MIN. EMBEDMENT SHEET NAME = AND FLAT WASHER EQUIP. DETAIL (E) BUILDING PAGE NUMBER REVISION STRUCTURE PV4 0 (1) 8 AWGTHHN/THWN-2,CU.,BLACK(L1) 26.0 A AC (2) 10 AWGTHHN/THWN-2,CU.,BLACK(L1) MAX 13.0 A AC (1) 12-2 UF-B W/G,THHN/THWN-2,SOLID CU. MAX13.0 A AC (1) 12-2TC-ER,THWN-2,CU. MAX 13.0 A AC 15 (1) 8 AWG THHN/THWN-2,CU.,RED(L2) 240 V AC (2) 10 AWGTHHN/THWN-2,CU.,RED(L 2) 240 V AC 240 V AC (1) 6 AWG BARE,CU(EGC) 240 V AC .7 (1) 10 AWG THHN/THWN-2,CU.,WHITE(N) 10 AWGTHHN/THWN-2,CU.,GREEN(EGC) (1) 10 AWGTHHN/THWN-2,CU.,GREEN(EGC) (1) 3/4 INCH EMT BLUE RAVEN EXTERIOR (1) 3/4 INCH EMT EXTERIOR INTERIOR EXTERIOR ALL CONDUIT TO BE RAN AT LEAST 7/8"ABOVE ROOF SURFACE WHERE EXPOSED TO SUNLIGHT. 1220 S.630 E STE.430 AMERICAN FORK,UT 84003 800-377-4480 WWW.BLUERAVENSOLAR.COM (26)JinKO Solar Eagle JKM 310M-60L CONFIDENTIAL-THE INFORMATION UL 1703 COMPLIANT HEREIN CONTAINED SHALL NOT BE (26)Enphase 107-60-2-US MICRO INVERTERS UL 1741 COMPLIANT BLUERUSED BEDISCLOSEDAVENSOLANYONEAEXCEPTR NOBENEFITWHOLER SHALL IT 7 MODULES MAX FOR ALL SUB-BRANCH IN JUNCTION BOX CIRCUIT(S)TO COMPLY WITH VRISE CALCS PART TO FOR OTHERSTHEIN OUTSIDE OF Enphase ID Combiner 3 RECIPIENTS ORGANIZATION, X-IO-AM1-240-3 (OPTIONAL IF UF-B EXCEPT IN CONNEC TION WITH THE (SOLAR LOADS ONLY) CABLE USED FOR SALE AND USE OF THE RESPECTIVE ENTIRE HOMERUN) JUNCTION BOX EQUIPMENT,WITHOUT THE WRITTEN PERMISSION OF (E)225A MAIN SERVICE PANEL _ ' (E)200A/2P MAIN BREAKER (N)20A/2P (1) CIRCUIT BLUERAVENSOLAR LLC. �+ l' L' 1 —ti — OF 13 MODULES \''' ® PV AC DISCONNECT NABCE NON-FUSED (E)200A/2P LOCKABLE,VISIBLE OPEN c 1 c P 60A,240V,2-POLE — N I V V CERTIFIED — (E)LOADSPV INSTALLATION O JUNCTION BOX 0 PROFESSIONAL • C.11 (N)40A/2P — (N)20A/2P Scott Gurney (1) CIRCUIT #PV-011719-015866 II Lz _n a� (} `z Lz n LZ n —�—^ OF----MODULES \ CONTRACTOR: E� �_ G j _ BRS FIELD OPS 120/240 VAC — J 385.498.6700 60HZ TO UTILITY GRID 15 3O O 1O Li). B✓ PV BREAKER TO BE LOCATED OPPOSITE U END OF BUSSING FROM MAIN BREAKER // �� c (E) GROUNDING 1 t '. � a ELECTRODE(S) ��� f, j 4,4 �� , � CO E �} 06 0 CO N Li � �rg-,:-. ..-1.mtv! . i't 1 \ _. . ..41.-......,,, ,„ a., . . ..,,,,,g g_, ,��� \ < N r \°\ C� 1. '''''''' : \ -'-i-''''''''T ---- ''''''' . - - . : - :---:::::A4;. ',:irr.,-.0:,,,,,,;;,:-:-.- ....-:- :1'.;;;;;,,,,,;-',- INTERCONNECTION NOTES N 111 L Z 0 1. ONE OF THE METHODS THAT FOLLOWS SHALL BE USED TO DETERMINE THE RATINGS OF t O > .:„.i.:: BUSBARS AND PANELBOARDS. (a)THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUT i. � -_'e ,. LU 't as CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE ' ' , co I— L ' _0) o BUSBAR SHALL NOT EXCEED THE AMPACITY OF THE BUS BAR. (b)WHERE TWO SOURCES, ;moi. -- CO 0 — F- 0 ONE THE UTILITY AND THE OTHER AN INVERTER ARE LOCATED AT OPPOSITE ENDS OF A ,-- ---:-/:-- "I BUSBAR THAT CONTAINS LOADS,THE SUM OF 125 PERCENT OF THE INVERTER(S)OUTPUTN. 'a DRAWING BY � � Kate Petersen CIRCUIT CURRENT AND THE RATING OF THE OVERCURRENT DEVICE PROTECTING THE G a . ) BUSBAR SHALL NOT EXCEED 120 PERCENT OF THE AMPACITY OF THE BUSBAR[NEC 705.12]. ( �: r, t. p DATE 9� r �. May 9, 2019 t ; DISCONNECT NOTES v s. , 1. DISCONNECTING SWITCHES SHALL BE WIRED SUCH THAT WHEN THE SWITCH IS % 1vN PROJECT NUMBER y OPENED THE CONDUCTORS REMAINING LIVE ARE CONNECTED TO THE A 61338165 P: a i € TERMINALS MARKED"LINE SIDE"(TYPICALLY THE UPPER TERMINALS) �ji 2. AC DISCONNECT MUST BE ACCESSIBLE TO QUALIFIED UTILITY PERSONNEL,BE _ i y SHEET NAME LOCKABLE,AND BEA VISIBLE-BREAK SWITCH ) ELEC. 3 LINE DIAG. a. 3 PAGE NUMBER REVISION PV5 0 • MODULE SPECIFICATIONS JinKO Solar Eagle JKM 310M-60L DESIGN LOCATION AND TEMPERATURES CONDUCTOR SIZE CALCULATIONS RATED POWER(STC) 310 W TEMPERATURE DATA SOURCE ASHRAE 2%AVG. HIGH TEMP MICROINVERTER TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.0 A AC MODULE VOC 41 V DC STATE Oregon JUNCTION BOX(1) MAX.CURRENT(ISC X1.25)= 16.3 A AC MODULE VMP 33 V DC CITY Tigard CONDUCTOR(TC-ER,COPPER(90°C)) = 12 AWG BLUE RAVEN MODULE IMP 9.4 A DC WEATHER STATION AURORA STATE CONDUCTOR RATING= 30 A MODULE ISC 9.9 A DC ASHRAE EXTREME LOW TEMP(°C) -5 AMB.TEMP.AMP.CORRECTION= 0.96 VOC CORRECTION(%/°C) -0.3 °C ASHRAE 2%AVG. HIGH TEMP(°C) 32 ADJUSTED AMP.= 28.8 > 16.3 1220 S.630 E STE.430 VMP CORRECTION (%/°C) -0.4°C JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.0 A AC AMERICAN FORK,UT 84003 SERIES FUSE RATING 20 A DC SYSTEM ELECTRICAL SPECIFICATIONS CIR 1 CIR 2 CIR 3 CIR 4 CIR 5 CIR 6 JUNCTION BOX(2) MAX.CURRENT(ISC X1.25)= 16.3 A AC 800-377-4480 W W W.BLUERAVENSOLAR.COM ADJ. MODULE VOC @ ASHRAE LOW TEMP 43.9 V DC NUMBER OF MODULES PER MPPT 13 13 CONDUCTOR(UF-B,COPPER(60°C))= 12 AWG ADJ. MODULE VMP @ ASHRAE 2%AVG. HIGH TEMP 28.2 V DC DC POWER RATING PER CIRCUIT(STC) 4030 4030 CONDUCTOR RATING= 20 A CONFIDENTIAL-THE INFORMATION HEREIN CONTAINED SHALL NOT BE TOTAL MODULE NUMBER 26 MODULES CONDUIT FILL DERATE= 1 USED FOR THE BENEFIT OF ANYONE EXCEPT MICROINVERTER SPECIFICATIONS Enphase IQ7-60-2-US SIC RATING OF ARRAY 8060W DC AMB.TEMP.AMP.CORRECTION= 0.96 BLUERAVENSOLAR NOR SHALL IT POWER POINTTRACKING(MPPT)MIN/MAX 22 - 48 V DC AC CURRENT @ MAX POWER POINT(IMP) 13.0 13.0 ADJUSTED AMP.= 19.2 > 16.3 BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE MAXIMUM INPUTVOLTAGE 48 V DC MAX.CURRENT(IMP X 1.25) 16.25 16.25 JUNCTION BOX TO MAX.SHORT CIRCUIT CURRRENT(ISC)= 13.0 A AC RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE MAXIMUM DC SHORT CIRCUIT CURRENT 15 A DC OCPD CURRENT RATING PER CIRCUIT 20 20 COMBINER BOX(3) MAX.CURRENT(ISC X1.25)= 16.3 A AC SALE AND USE OF THE RESPECTIVE MAXIMUM USABLE DC INPUT POWER 350 W MAX.COMB.ARRAY AC CURRENT(IMP) 26.0 CONDUCTOR(UF-B,COPPER 60°C = 10 AWG EQUIPMENT,WITHOUT THE 1 ( )) WRITTEN PERMISSION OF MAXIMUM OUTPUT CURRENT 1 A AC MAX.ARRAY AC POWER 6240W AC CONDUCTOR RATING= 30 A BLUERAVENSOLAR LLC. AC OVERCURRENT PROTECTION 20 A CONDUIT FILL DERATE= 0.8 MAXIMUM OUTPUT POWER 240 W AC VOLTAGE RISE CALCULATIONS DIST(FT) VRISE(V) VEND(V) %VRISE IQ7-7 AMB.TEMP.AMP.CORRECTION= 0.96 NABCEP CEC WEIGHTED EFFICIENCY 97 % VRISE SEC.1(MICRO TOIBOX) 25.2 0.71 240.71 0.30% ADJUSTED AMP.= 23.04 > 16.3 CERTIFIED VRISE SEC.2(JBOX TO COMBINER BOX) 45 2.36 242.36 0.98% COMBINER BOX TO INVERTER RATED AMPS= 26.0 A AC PV INSTALLATION AC PHOTOVOLATIC MODULE MARKING(NEC 690.52) VRISE SEC.3(COMBINER BOX TO POI) 5 0.20 240.20 0.09% MAIN PV OCPD(15) MAX.CURRENT(RATED AMPS X1.25)= 32.5 A AC PROFESSIONAL NOMINAL OPERATING AC VOLTAGE 240 VAC TOTAL VRISE 1.37% CONDUCTOR(THWN-2,COPPER(75°C TERM.))= 8 AWG Scott Gurney NOMINAL OPERATING AC FREQUENCY 47-68 HZ AC CONDUCTOR RATING= 50 A #PV-011719-015866 MAXIMUM AC POWER 240 VA AC PHOTOVOLTAIC AC DISCONNECT OUTPUT LABEL(NEC 690.54) CONDUIT FILL DERATE= 1 CONTRACTOR: MAXIMUM AC CURRENT 1.0 A AC AC OUTPUT CURRENT 26.0 A AC AMB.TEMP.AMP.CORRECTION= 0.96 BRS FIELD OPS MAXIMUM OCPD RATING FOR AC MODULE 20 A AC NOMINAL AC VOLTAGE 240 VAC ADJUSTED AMP.= 48 > 32.5 385.498.6700 46 a) 4) L 0 GROUNDING NOTES STRANDED,AND BARE WHEN EXPOSED. 690.8] FOR MULTIPLE CONDUCTORS 5 0 1. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH[NEC 690-47]AND 11.EQUIPMENT GROUNDING CONDUCTORS SHALL BE SIZE ACCORDING TO[NEC 8. ALL PV DC CONDUCTORS IN CONDUIT EXPOSED TO SUNLIGHT SHALL BE INSTALLED C [NEC 250-50]THROUGH[NEC 250-60]SHALL BE PROVIDED.PER NEC, 690.45] AND BE A MINIMUM OF#10AWG WHEN NOT EXPOSED TO DAMAGE(#6AWG AT LEAST 7/8"ABOVE THE ROOF SURFACE AND DERATED ACCORDING TO[NEC TABLE CO GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND SHALL BE USED WHEN EXPOSED TO DAMAGE). 310.15(B)(2)(a),NEC TABLE 310.15(B)(3)(a),&NEC 310.15(B)(3)(c)]. f co BONDED TO AT THE SERVICE ENTRANCE.IF EXISTING SYSTEM IS INACCESSIBLE, 12.GROUNDING AND BONDING CONDUCTORS,IF INSULATED,SHALL BE COLOR 9. EXPOSED ROOF PV DC CONDUCTORS SHALL BE USE-2,90°C RATED,WET AND UV OR INADEQUATE,OR IS ONLY METALLIC WATER PIPING,A SUPPLEMENTAL CODED GREEN(OR MARKED GREEN IF#4 AWG OR LARGER) RESISTANT,AND UL LISTED RATED FOR 600V, UV RATED SPIRAL WRAP SHALL BE Z U) CO N GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION 13. ALL CONDUIT BETWEEN THE UTILITY AC DISCONNECT AND THE POINT OF USED TO PROTECT WIRE FROM SHARP EDGES _0 i � LLJ CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. CONNECTION SHALL HAVE GROUNDED BUSHINGS AT BOTH ENDS. 10. PHASE AND NEUTRAL CONDUCTORS SHALL BE DUAL RATED THHN/THWN-2 I- 'il- ( 0) N 2. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL 14.SYSTEM GEC SIZED ACCORDING TO[NEC 690.47],[NEC TABLE 250.66],DC INSULATED,90°C RATED,WET AND UV RESISTANT,RATED FOR 600V U O (n DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL(OR INVERTER)IF SYSTEM GEC SIZED ACCORDING TO[NEC 250.166],MINIMUM#8AWG WHEN 11. 4-WIRE DELTA CONNECTED SYSTEMS HAVE THE PHASE WITH THE HIGHER L 01 2 SMALLER THAN#6 AWG COPPER WIRE PER NEC 250-64B.THE GROUNDING ELECTRODE INSULATED,#6AWG WHEN EXPOSED TO DAMAGE. VOLTAGE TO GROUND MARKED ORANGE OR IDENTIFIED BY OTHER EFFECTIVE MEANS. O 4) D 2 LU CONDUCTOR WILL BE CONTINUOUS,EXCEPT FOR SPLICES OR JOINTS AT BUSBARS 15.EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, 12. ALL SOURCE CIRCUITS SHALL HAVE INDIVIDUAL SOURCE CIRCUIT PROTECTION LL C (0 0 H WITHIN LISTED EQUIPMENT PER[NEC 250.64C.]. EQUIPMENTS,AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN 13. VOLTAGE DROP LIMITED TO 2%FOR DC CIRCUITS AND 3%FOR AC CIRCUITS Z 0 O >- 3. 3. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN#8 AWG AND ACCORDANCE WITH 250.134 OR 250.136(A)REGARDLESS OF VOLTAGE. 14. NEGATIVE GROUNDED SYSTEMS DC CONDUCTORS SHALL BE COLOR CODED AS LU .L -4' (15 (/) NO GREATER THAN#6 AWG COPPER AND BONDED TO THE EXISTING GROUNDING FOLLOWS:DC POSITIVE-RED(OR MARKED RED),DC NEGATIVE-GREY(OR MARKED GREY) I- . ELECTRODE TO PROVIDE FOR A COMPLETE SYSTEM. WIRING&CONDUIT NOTES 15. POSITIVE GROUNDED SYSTEMS DC CONDUCTORS COLOR CODED: U) 0 - H 0 4. PV SYSTEM SHALL BE GROUNDED IN ACCORDANCE TO[NEC 250.21],[NEC TABLE 1.ALL CONDUIT SIZES AND TYPES,SHALL BE LISTED FOR ITS PURPOSE AND DC POSITIVE-GREY(OR MARKED GREY),DC NEGATIVE-BLACK(OR MARKED BLACK) 250.122], AND ALL METAL PARTS OR MODULE FRAMES ACCORDING TO[NEC APPROVED FOR THE SITE APPLICATIONS 16. AC CONDUCTORS>4AWG COLOR CODED OR MARKED: DRAWING BY 690.46]. 2.BOLTED CONNECTION REQUIRED IN DC DISCONNECTS ON THE WHITE GROUNDED PHASE A OR L1-BLACK,PHASE B OR L2-RED,PHASE C OR L3-BLUE,NEUTRAL- Kate Petersen 5. MODULE SOURCE CIRCUITS SHALL BE GROUNDED IN ACCORDANCE TO[NEC CONDUCTOR(USE POLARIS BLOCK OR NEUTRAL BAR) WHITE/GRAY 690.42]. 3. ANY CONNECTION ABOVE LIVE PARTS MUST BE WATERTIGHT.REDUCING WASHERS *USE-2 IS NOT INDOOR RATED BUT PV CABLE IS RATED THWN/THWN-2 AND MAY DATE 6. THE GROUNDING CONNECTION TO A MODULE SHALL BE ARRANGED SUCH THAT DISALLOWED ABOVE LIVE PARTS,MEYERS HUBS RECOMMENDED BE USED INSIDE May 9, 2019 THE REMOVAL OF A MODULE DOES NOT INTERRUPT A GROUNDED CONDUCTOR 4. UV RESISTANT CABLE TIES(NOT ZIP TIES)USED FOR PERMANENT WIRE MANAGEMENT **USE-2 IS AVAILABLE AS UV WHITE TO ANOTHER MODULE. OFF THE ROOF SURFACE IN ACCORDANCE WITH NEC 110.2,110.3(A-B).300.4 17. RIGID CONDUIT,IF INSTALLED,(AND/OR NIPPLES)MUST HAVE A PULL BUSHING TO PROJECT NUMBER 7. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED CONNECTIONS POINTS 5. SOLADECK JUNCTION BOXES MOUNTED FLUSH W/ROOF SURFACE TO BE USED FOR PROTECT WIRES. 61338165 IDENTIFIED IN THE MANUFACTURER'S INSTALLATION INSTRUCTIONS. WIRE MANAGEMENT AND AS FLASHED ROOF PENETRATIONS FOR INTERIOR CONDUIT 18. IF CONDUIT DETERMINED TO BE RAN THROUGH ATTIC IN FIELD THEN CONDUIT WILL 8. ENCLOSURES SHALL BE PROPERLY PREPARED WITH REMOVAL OF PAINT/FINISH RUNS. BE EITHER EMT,FMC,OR MC CABLE IF DC CURRENT COMPLYING WITH NEC 690.31,NEC SHEET NAME AS APPROPRIATE WHEN GROUNDING EQUIPMENT WITH TERMINATION 6. ALL PV CABLES AND HOMERUN WIRES BE TYPE USE-2,AND SINGLE-CONDUCTOR 250.118(10).DISCONNECTING MEANS SHALL COMPLY WITH 690.13 AND 690.15 ELEC. CALCS. GROUNDING LUGS. CABLE LISTED AND IDENTIFIED AS PV WIRE,TYPE TC-ER,OR EQUIVALENT; ROUTED TO 19. CONDUIT RAN THROUGH ATTIC WILL BE AT LEAST 18"BELOW ROOF SURFACE 9. GROUNDING SYSTEM COMPONENTS SHALL BE LISTED FOR THEIR PURPOSE,AND SOURCE CIRCUIT COMBINER BOXES AS REQUIRED COMPLYING WITH NEC 230.6(4)AND SECURED NO GREATER THAN 6'APART PER NEC PAGE NUMBER REVISION GROUNDING DEVISES EXPOSED TO THE ELEMENTS SHALL BE RATED FOR DIRECT BURIAL. 7.ALL CONDUCTORS AND OCPD SIZES AND TYPES SPECIFIED ACCORDING TO[NEC 330.30(B). n\,G 0 10. GROUNDING AND BONDING CONDUCTORS SHALL BE COPPER,SOLID OR 1�V V LABEL 1 LABEL 7 A FOR PV DISCONNECTING MEANS WHERE ALL WARNING: PHOTOVOLTAIC AT DIRECT-CURRENT EXPOSED RACEWAYS,CABLE TRAYS,COVERS AND ENCLOSURES OF JUNCTION BOXES,AND OTHER TERMINALS OF THE DISCONNECTING MEANS MAY BEPOWER WIRING METHODS;SPACED AT MAXIMUM 10FT SECTION OR WHERE SEPARATED BY ENCLOSURES.WALLS,PARTITIONS, ELECTRIC SHOCK HAZARD ENERGIZED IN THE OPEN POSITION. CEILINGS.CEILINGS.OR FLOORS. f TERMINALS ON THE LINE AND [NEC 690.13(B),NEC 705.22] [NEC 690.31(G)(3&4)] `E RAVEN LOAD SIDES MAY BE ENERGIZED ,-F.- IN THE OPEN POSITION A /y LABEL 8 SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT SHUT DOWN THE ARRAY ;� ,4'': LABEL 11 @a\ IV` . PERMANENT DIRECTORY TO BE LOCATED AT 1220 S.630 E STE.430 WITH RAPID SHUTDOWN AND CONDUCTORS LEAVING THE ARRAY: 'w""�' MAIN SERVICE EQUIPMENT LOCATION IF ALL AMERICAN FORK,UT 84003 �„ �,,� SIGN TO BE LOCATED ON OR NO MORE THAN 3 MAIN DISTRIBUTION UTILITY DISCONNECT(S) LABEL 2 TURN RAPID SHUTDOWN ELECTRICAL POWER SOURCE DISCONNECTING FT AWAY FROM SERVICE DISCONNECTING POWER TO THIS BUILDING IS ALSO SUPPLIED 800-377-4480 DIRECT CURRENT AT EACH DC DISCONNECTING MEANS,INCLUDING THE SWITCH TO THE FROM AROOF MOUNTED SOLAR ARRAYWTH MEANS (SOLAR ARRAY RAPID SHUTDOWN "::yy`°�,, ` DC DISCONNECT AT THE INVERTER. OFF POSITION TO MEANS TO WHICH THE PV SYSTEMS ARE ARAPID SHUTDOWN DISCONNECTING MEANS SWITCH)ARE GROUPED AND IN LINE OF SITE OF WWW.BLUERAVENSOLAR.COM PHOTOVOLTAIC SOURCE SHUTDOWNPVSYSTEAI �' CONNECTED AND SHALL INDICATE THE GROUPED AND LABELED WITHIN LINE OF SITE -���e,�-, � [NEC 690.53,NEC 690.13(B)] AND REDUCE AND 10 FT OF THIS LOCATION. MAIN SERVICE DISCONNECTING MEANS. LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN CONFIDENTIAL-THE INFORMATION SHOGKHAZARp , [NEC 690.56(C)&NEC 705.10]. I MAXIMUM VOLTAGE VDC _INTHEARRAY SWITCHES IF NOT AT THE SAME LOCATION. HEREIN CONTAINED SHALL NOT BE MAX CIRCUIT CURRENT AMPS [NEC 690.56(C)(1)(A)] USED FOR THE BENEFIT OF 'mANYONE EXCEPT LABEL 12 LABEL 9 ��4► PERMANENT DIRECTORY TO BE LOCATED AT BLUERAVENSOLARDISCLOSED NOR SHALL IT SOLAR PV SYSTEM EQUIPPED FOR PV SYSTEMS THAT ONLY SHUT DOWN SOLAR ARRAY RAPID SHUTDOWN SWITCH BE RTTOTHERS WHOLE IDOIN POWER TO THIS BUILDING IS ALSO PART TO OUTSIDE LABEL 3 WITH RAPID SHUTDOWN CONDUCTORS LEAVING THE ARRAY: DENOTING THE LOCATION OF THE SERVICE RECIPIENTS ORGANIZATION, PHOTOVOLTAIC SYSTEM AT POINT OF INTERCONNECTION,MARKED AT AC TURN RAPID SHUTDOWN SWITCH SIGN TO BE LOCATED ON OR NO MORE THAN 3 FT AWAY FROM SERVICE DISCONNECTING SUPPLIED FROM MAIN DISTRIBUTION UTILITY DISCONNECT LOCATED EQUIPMENT LOCATION IF SOLAR ARRAY RAPID SHUT DOWN DISCONNECT SWITCH IS NOT EXCEPT IN CONNEC TION WITH THE A DISCONNECTING MEANS. TOTHE'OFFPOSMON rii A SALE AND USE OF THE RESPECTIVE AC DISCONNECT A [NEC 690.54,NEC 690.13(8)] TO SHUT CONN DDNOUCTORS MEANS TO WHICH THE PV SYSTEMS ARE GROUPED AND WITHIN LINE OF SITE OF MAIN EQUIPMENT,WITHOUT THE OUTSIDE1HEARRAY CONNECTED AND SHALL INDICATE THE SERVICE DISCONNECTING MEANS. WRITTEN PERMISSION OF CONDUDWORswITHN rLi LOCATION OF ALL IDENTIFIED RAPID SHUTDOWN [NEC 705.10] BLUERAVENSOLAR LLC. RATED AC OUTPUT CURRENT A THEARRAYREhMAIN EJERGIZEDINSUNUGHT SWITCHES IF NOT AT THE SAME LOCATION. NOMINAL OPERATING AC VOLTAGE V '" [NEC 690.56(C)(1)(B)] LABEL 13 al " ' PERMANENT DIRECTORY TO BE LOCATED AT MAIN NABC EP ---‘....,-.4‘,----- ,-- SERVICE EQUIPMENT DENOTING THE LOCATION r te—�� �� � ;. LABEL 4 ��t , ^� LABEL 10 POWER TO THIS BUILDING IS ALSO SUPPLIED OF THE PV RAPID SHUTDOWN SYSTEMCERTIFIED / �= AT POINT OF INTERCONNECTION FOR EQUIPMENT `I � TOti-`V N SIGN LOCATED AT RAPID SHUT DOWN FROM ROOF MOUNTED SOLARARR Y.SOLAR � �" DISCONNECTING MEANS IF SOLAR ARRAY RAPID [ CONTAINING OVERCURRENT DEVICES IN CIRCUTS C" �� DISCONNECT SWITCH[NEC 690.56(C)(3)]. ARRAY RAPID SHUTDOWN DISCONNECT IS SHUT DOWN DISCONNECT SWITCH IS NOT PV INSTALLATION SUPPLYING POWER TO A BUSBAR OR CONDUCTOR { \��A��� �. }���+ p LOCATED OUTSIDE NocrrovmumMEIER. GROUPED AND WITHIN LINE OF SITE OF MAIN PROFESSIONAL DUAL POWER SUPPLY SUPPLIED FORM MULTIPLE SOURCES,EACH SERVICE SC)L�; ' T L7 i M SERVICE DISCONNECTING MEANS. 705.10, Scott Gurney SOURCES:UTILITY GRID AND EQUIPMENT AND ALL ELECTRIC POWER PRODUCTION �� 'A NEC 690.56(C)(1)] [NEC[ #PV-011719-015866 PV SOLAR ELECTRIC SYSTEM SOURCE LOCATIONS. [NEC 705.12(B)(3)] CONTRACTOR: LABELING DIAGRAM FOR MICRO INV.: BRS FIELD OPS MAIN SERVICE PANEL 385.498.6700 LABELS a PLACED ADJACENT TO THE BACK-FED BREAKER EXISTING SUB PANEL PV COMBINER AIN O �$ (IF WHERE POINT OF SUBPANEL- .� ; , % FROM THE INVERTER IF TIE IN CONSISTS OF LOAD INTERCONNECTION IF USED TO COMBINE AC JUNCTION BOX INVERTER OUTPUT CONNECTION SIDE CONNECTION TO BUSBAR. IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS OR AC COMBINER BOX i) [NEC 705.12(B)(2)(3)(b)] U DO NOT RELOCATE O&O4 }, D D IF BREAKER USEDO O O 1O 4S o THIS OVERCURRENT DEVICE DDD O&O 10 O TO ORO11 O OR 13 IF BREAKER USED CD PLACARD 12 OR 4 f6 U C) LABEL 6 O (ONLY IF 3 OR MORE SUPPLY SOURCES TO O O PLACARD Zcd N SIGN LOCATED AT LOAD CENTER IF IT (ONLY IF PV (ONLY IF PV O Q N m h- LLI THIS EQUIPMENT FED BY MULTIPLE CONTAINS 3 OR MORE POWER SOURCES. INTERCONNECTION NTERCONNECTION I— .L (n 0) N SOURCES.TOTAL RATING©FALL [NEC 705.12(B)(2)(3)(C)] CONSISTS OF LOAD CONSISTS OF LOAD — 11 U N C (/) SIDE BREAKER) SIDE BREAKER) OVERCURRENT DEVICES,EXCLUDING — ct >_ MAIN SUPPLY OVERCURRENT 0 4) 5 2 w DEVICE,SHALL NOT EXCEED LABELING DIAGRAM FOR STRING INV./DC OPTIMIZER INV.: IL Q 0 Q H AMPACITY OF BUSBAR. MAIN SERVICE PANEL z O O - C.., O EXISTING SUB PANEL PV COMBINER SUBPANEL- INVERTER(S) uJ .L v. tB (n (IF WHERE POINT OF _ . M0) CD &O INTERCONNECTION IF USED TO COMBINE (1) 0 ,-- I- 0 IS MADE) AC DISCONNECT PV OUTPUT CIRCUITS IF BREAKER USED DRAWING BY ❑ ❑ 00 O (DOR® Kate Petersen o ❑ ❑ O&O O O DATE 1)OR 10 IF BREAKER USED Ac JUNCTION BOX May 9, 2019 OR PLACARD @ OR II LABELING NOTES: PLACARD O oc OR COMBINER BOX 1. LABELS CALLED OUT ACCORDING TO ALL COMMON CONFIGURATIONS.ELECTRICIAN TO O O PROJECT NUMBER DETERMINE EXACT REQUIREMENTS IN THE FIELD PER CURRENT NEC AND LOCAL CODES AND (ONLY IF PV (ONLY IF PV O° 1O 1 O O OO 61338165 MAKE APPROPRIATE ADJUSTMENTS. INTERCONNECTION NTERCONNECTION 2. LABELING REQUIREMENTS BASED ON THE 2017 NATIONAL ELECTRIC CODE,OSHA STANDARD CONSISTS OF LOAD -3ONSISTS OF LOAQ 11 o-,.... 0O 19010.145,ANSI Z535. SIDE BREAKER) SIDE BREAKER) O SHEET NAME 3. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION. LABELS 4. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED[NEC INTEGRATED DC DISCONNECT 110.21] 5. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8",WHITE ON RED BACKGROUND;REFLECTIVE, *ELECTRICAL DIAGRAM SHOWN ABOVE IS FOR LABELING PURPOSES ONLY. NOT AN ACTUAL REPRESENATION OF EQUIPMENT AND CONNECTIONS TO BE INSTALLED. LABEL LOCATIONS PAGE NUMBER REVISION AND PERMANENTLY AFFIXED[IFC 605.11.1.1] PRESENTED MAY VERY DEPENDING ON TYPE OF INTERCONNECTION METHOD AND LOCATION PRESENTED ON PV5 OF 3 LINE DIAGRAM. PV5 LINE DIAGRAM TO REFLECT ACTUAL REPRESENTATION OF PROPOSED SCOPE OF WORK. PV8 0 BLUE RAVEN Enphase iviic=oinvert rs 1220 S.630 E STE.430 Enphase IQ 7 and IQ 7+ Microinverters AMERICAN FORK,UT 84003 INPUT DATA(DC) IQ7-60-2-US I IQ7-60-B-US IQ7PLUS-72-2-US/IQ7PLUS-72-B-US 800-377-4480 - - WWW.BLUERAVENSOLAR.COM Commonly used module pairings' 235 W-350 W+ 235 W-440 W+ Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modules CONFIDENTIAL-THE INFORMATION The high-powered smartMaximum input DC voltage 48 V 60 V HEREIN CONTAINED SHALL NOT BE USED FOR THE BENEFIT OF En pliase Peak power tracking voltage 27 V-37 V 27 V-45 V ANYONE EXCEPT En hale 7 tC=r and n S f [CT" Operating range 16V-4$V 16V-60V BLUERAVENSOLAR NOR SHALL IT I ( `F" dramatically simplify the instal lotion process wh e Min/Max start voltage 22 V/48 V 22 V/60 V BE DISCLOSED IN WHOLE OR IN -C �-t Max DC short circuit current(module lac) 15 A 15A PART TO OTHERS OUTSIDE achieving the highest system efficiency. Overvoltage class DC port II II RECIPIENTS ORGANIZATION, EXCEPT IN CONNEC TION WITH THE $.oinvetx:.ters DC port backfeed current 0 A 0A SALE AND USE OF THE RESPECTIVE Part oft the Enphase 10 System,the IQ 7 and PV array configuration 1 x 1 ungrounded array;No additional DC side protection required; EQUIPMENT,WITHOUT THE 10 T Microinverters Inti r t with the En ase AC side protection requires max 20A per branch circuit WRITTEN PERMISSION OF gOUTPUT DATA(AC) IQ 7 Microinverter IQ 7+Microinverter BLUERAVENSOLAR LLC. 10 Envoy-,Enphase 10 Battery-,and the Enphase Peak output power 250 VA 295 VA Enlighten-monitoringy Maximum continuous outputpower 240 VA 290 VA tY and analysis software_ p � o � Nominal(L-L)voltagelranget 240 V/ 208 V/ 240 V/ 208V/ L l 14 _V' 0 d- Q Series Microinverters extend the reliability 211-264 V 183-229 V 211-264V 183229V 0I— 0 c} Maximum continuous output current 1.0 A(240 V) 1.15 A(208 V) 1.21 A(240 V) 1.39 A(208 V) Q Et 03 0 I.._ standards set forth by previous generations and Nominal frequency 60 Hz 60 Hz Z (D (7 < Z co overar'T�lia"hourscf Extended frequency range 47-68 Hz 47-68 Hz undergopower-on n testing, 2 I— '-n I— til o AC short circuit fault current over 3 cycles 5.8 Arms 5.8 Arms 00 Z > O enabling Enphase to provide an industry-leading Maximum units per 20 A(L-L)branch circuit' 16(240 VAC) 13(208 VAC) 13(240 VAC) 11(208 VAC) 0 M 0 < Overvoltage class:AC port III III U (� 0 W warranty of up to 25 years_ W AC port backfeed current 0 A 0 A • (/) LU Power factor setting 1.0 1.0 0 J Power factor(adjustable) 0.7 leading...0.7 lagging 0.7 leading...0.7 lagging tY m EFFICIENCY @240 V @208 V @240 V @208 V Peak CEC efficiency 976% 97.6% 97.5% 97.3 CEC weighted efficiency 97.0% 97.0% 97.0% 97.0% E to Install MECHANICAL DATA Ambient temperature range -40°C to+65°C ! Lightweight andsimple Relative humidity range4%to 100%(condensin9) 1 • Faster installation with improved,lightertwo-wire cabling Connectortype(1Q7-60-2-US&IQ7PLUS-72-2-US) MC4(or Amphenol H4 UTX with additional Q-DCC 5 adapter) 1 Connector type(107-60-B-US&IQ7PLUS-72-B-US) Friends PV2(MC4 intermateable). j ▪ Built-in rapid ehutr vvtt compliant(NEC2014 2Q 7) Adaptors for modules with MC4 or UTX connectors: -PV2 to MC4:order ECA-S20-S22 I • -PV2 to UTX.order ECA-S20-S25 Productive and Reliable Dimensions(WxHxD) 212 mm:x 175 mm x 30.2 mm(without bracket) ,. � Weight 1.08 kg(2.38 lbs) ' ' • Op rf zed for high powered 60-cell and 72-cel*modules Cooling Natural convection-No fans • Mare than a minim hours of testing Approved for wet locations Yes ▪ Class II double-insulated gr Pollution degree PdS • UI listed Enclosure Class II double-insulated,corrosion resistant polymeric enclosure Environmental category/UV exposure rating NEMA Type 6/outdoor EN+ asr FEATURES 100 Smart Grid Ready Communication Power Line Communication(PLC); Monitoring Enlighten Manager and MyEnlighten monitoring options. • Complies with advanced grid st port,voltage and Both options require installation of an Enphase IQ Envoy. 1 -= frequencyride ride-through req irem ens DiIlesconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break " ` disconnect required by NEC 690. • Remotely updates to respond to charging grid requirements Compliance CA Rule 21(UL 1741-SA) Configurable varyingUL 62109-1,UL1741/IEEE1547,FCC Part 15 Class B, ICES-0003 Class B, • g€rrfal� grid profiles CAN/CSA-C22.2 NO.107.1-01 • Meets CA Rule 21(UL 1741- A) This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22 1-2015 Rule 64-218 Rapid Shutdown of PV Systems,for AC and DC conductors,when installed according manufacturer's instructions. The tO 7+Micro ks required to support 72-cell modules_ l6#TInE10@ 1.No enforced DC/AC ratio.See the compatibility calculator at r . 1.1. • . i -r. _t .ort mo.ule- •no ti i.'" miritia 2.Nominal voltage range can be extended beyond nominal if required by the utility. OSS p� r rrn+a�� �*w f� 3.Limits may vary.Refer to local requirements to define the number of microinverters per branch in your area. r�{fir yy H �y Mr' SHEET NAME To learn more about Enphase offerings,visit enphase.com 6u.1.F i a�k� To learn more about Enphase offerings,visit enphase.com EN PHASE. DATA SHEET ©2018 Enphase Energy.All rights reserved.All trademarks or brands used are The property of Enphase Energy,Inc. 2018-05-24 PAGE NUMBER REVISION DS 0 BLUE RAVEN L;.a-ta 3i eet Enphase IQ Combiner 3 Enphase Networking 1220 S.630 E STE.430 MODEL NUMBER AMERICAN FORK,UT 84003 IQ Combiner 3 X-IQ AM1-240-3 IQ Combiner 3 with Enphase IQ Envoy'printed circuit board for integrated revenue grade PV 800-377-4480 production metering(ANSI C12.20+/-0 5%)and optional*consumption monitoring(+1-2 5%). WWW.BLUERAVENSOLAR.COM ACCESSORIES and REPLACEMENT PARTS(not included,order separately) Enphase Mobile Connect" CONFIDENTIAL-THE INFORMATION CELLMODEM-03(4G/12-year data plan) Plug and play industrial grade cellular modem with data plan for systems up to 60 HEREIN CONTAINED SHALL NOT BE CELLMODEM-01(3G/5-year data plan) microinverters,(Available in the US,Canada,Mexico,Puerto Rico,and the US Virgin Islands, USED FOR THE BENEFIT OF CELLMODEM-M1(4G based LTE-M/`5-year data plan) where there is adequate cellular service in the installation area.) ANYONE EXCEPT The Enphase{Q Combiner "' with Enphase BLUERAVENSOLAR NOR SHALL IT Enphase p p Consumption Monitoring CT BE DISCLOSED IN WHOLE OR IN CT-200-SPLIT Split core current transformers enable whole home consumption metering(+/-2.5%). PART TO OTHERS OUTSIDE IQ Envoy'consolidates interconnection RECIPIENTS ORGANIZATION, r BRK-10A-2-2 0 Supports Eaton BR210,BR215,BR220,BR230,BR240,8R250,and BR260 circuit breakers. EXCEPT IN CONNEC TION WITH THE equipment into a single enclosure and BRK-15A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 SALE AND USE OF THE RESPECTIVE g BRK i5A-2-240 Circuit breaker,2 pole,15A,Eaton BR215 EQUIPMENT,WITHOUT THE (X-IQ-AM1-230-3) stream'ines PV and storage installations by BRK-20A-2P-240 Circuit breaker,2pole,20A,Eaton BR220 WRITTEN PERMISSION OF EPLC-01 Power line carrier(communication bridge pair),quantity 2 BLUERAVENSOLAR LLC. providing a consistent,pre-wired solution for XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3(required for EPLC-01) XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board(PCB)for Combiner 3 In O L CL CO residentia app ications. It offers up to four ELECTRICAL SPECIFICATIONS 0Z ,:t. H 0 � 2-pole input circuits and aton BR series Z D co Q Q 1- Rating Continuous duty busbar assembly. System voltage 120/240 VAC,60 Hz G( 0 ws:t ct W M Eaton BR series busbar rating 125 A 2 H 6 Z u- O Max.continuous current rating(output to grid) 65 A U M 0 0 W co CL Max.fuse/circuit rating(output) 90 A LLI ° 0 m Branch circuits(solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation(DG)breakers only(not included) O Max.continuous current rating(input from PV) 64 A (Y Max.total branch circuit breaker rating(input) 80A of distributed generation/90A with IQ Envoy breaker included a- Smart Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy • Includes IQ Envoy for communication MECHANICAL DATA € and control - - ---- - Dimensions(WXHxD) 49.5 x 37.5 x 16.8 cm(19.5'x 14.75'x 6.63").Height is 21.06"(53.5 cm with mounting brackets). ) a • Flexible networking supports Wi-Fi, Ethernet,or cellular Weight 7.5 kg(16.5 lbs) I Ambient temperature range -40°C to+46°C 40°to115°F r Optional AC receptacle available for PLC P 9 ( ) ' ," ' ,u' �% bridge Cooling Natural convection,plus heat shield f °( I ' .-T ", , • Provides production metering and optional Enclosure environmental rating Outdoor,NRTL-certified,NEMA type 3R,polycarbonate construction r consumption monitoring Wire sizes •• 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors r 'i:4. l > f 60 A breaker branch input: 4 to 1/0 AWG copper conductors I • Main lug combined output: 10 to 2/0 AWG copper conductors i i, • Neutral and ground: 14 to 1/0 copper conductors i0 t':0- i Simple Always follow local code requirements for conductor sizing. F a j' • Reduced size from previous combiner Altitude To 2000 meters(6,560 feet) r , 1.---= l' • Centered mounting brackets support single INTERNET CONNECTION OPTIONS .i . " lr r stud mounting ,802.. -- .! • Integrated Wi-Fi 802:11b/g/.n I 6 • Supports back and side conduit entry Ethernet Optional,802.3,Cat5E(or Cat 6)UTP Ethernet cable (not included) £ /„ .' i • Up to four 2-pole branch circuits for 240 VAC Cellular Optional,CELLMODEM-01(3G)or CELLMODEM-03(4G) or CELLMODEM-M1(4G based LTE-M) P P - plug-in breakers(not included) (not included) gam: 1 :.0 '. 0-°- ° • 80 A total PV or storage branch circuits 9 COMPLIANCE Compliance,Combiner UL 1741 CAN/CSA C22.2 No. .1 Reliable 47 CFR,Part 15,Class 67 ICES 003 Production metering:ANSI C12.20 accuracy class 0.5(PV production) • Durable NRTL-certified NEMA type Compliance,IQ Envoy UL 60601-1/CANCSA 22.2 No.61010-1 3R enclosure 11;21 *Consumption monitoring is required for Enphase Storage Systems. • Five-year warranty • UL listed To learn more about Enphase offerings,visit enphase.com LISTEDEA 1 E. '°J 2018 Enphase Energy.Ail rights reserved.AlAll Trademarks or brands in this document are registered by trek respective o,vner. EN P HAS To learn more about Enphase offerings,visit enphase.com ��! G 2018-09-13 Nare SHEET NAME DATA SHEET PAGE NUMBER REVISION DS 0 ,d"s'.---,kkF JIIiOSOlc C.US Emiev,Yaw Th at Ln Saw \\ \� \r�r\\rr \:::\ �,-�'rtgx-� - - Current-Voltage- -of Te e. 3L\\i\\� r ��. �_ � ���� \.�\\��� \���\ "" .v nt Yoltage&Power V tae Temperature Dependence 1220630430 a / IIIIIN�I�illIIIIIIlIIIlllIIIII _— ;;,; Curves-(310W) orisc,Voc,Pmax AMERICAN FORK,UT 84003 i = � IIIIINIIIUIII111DIIINIt' tB0800-377-4480 x IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 150055 WWW.BLUERAVENSOLAR.COM s � ; 1111!IIIIIIIIIIIIIIIIIIIIIIIIIIIII a ,, CONFIDENTIAL-THE INFORMATION " _ r IIIIIIIIIIIIIIIII�lllllllll� ,o k ,. a HEREIN CONTAINED SHALL NOT BE - i, Illllllllllllllllllllllullllllll 6 y >rrn = USED FOR THE BENEFIT OF -,. a j -s "i , -» ^ oc ANYONE EXCEPT IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII -u. — x13.. IIIIIIIIIIIIIIIIIIIII�IIIIIbIII 3 1+ a Baa BLUERAVENSOLAR NOR SHALL IT \rc� � ' a '°co BE DISCLOSED IN WHOLE OR IN s'" s IIII III'I p z° PART TO OTHERS OUTSIDE I IIIIIIIIIIIIIIII�III�III' RECIPIENTS ORGANIZATION, - EXCEPTINCONNECTIONWITHTHE I��><IIIIIIII�III�III SALE AND USE OF THE RESPECTIVE ,ipo +t'1 - s EF,ont side Beck sr2 -25 0 25 50 75 Tl0 �� � voltage t eeld temperate etCl EQUIPMENT,WITHOUT THE �i�ty WRITTEN PERMISSION OF i % MOM BLUERAVENSOLAR LLC. m . ' ' CellType Mona PERC tsa and ce .(1.87S x�'SSJS�mm) in _x f, �- Z No of cells 60(6 10) Q CO 0 0 ® Dimensions- 1665x1002.35 m n(65 5s 3545 X-1.38 inch) Z D (33n < J l�- x Weight 9.0 g(a 9 i6s) Q CD d' W Co. KEY ,`q mar ,• off# (;igltTrassn ssol LowIcntTampa-adGlaxs �— cc Z (f� F Glass '.1-171 _ n .<;, -.'..„,‘„,. *-. 4,,> Frame - Anodl edAuhi:vumAlof o Q O w 00 Junction Box 1867 Rated W ° U m i } 30gcs/pattet,60pcSlstack,840pcs/40'HQ Container Output Caoles 12 AWG,Length 1000mm(3937;�n)o'Custom red Lengtt o Diamond Cell Thlo i_ ,. iecno9Y FlmeType Type ' Uniquely designed high performance 5 busbarmono PERC cell W _. , i ..._ _ _.„.._ � l PID FREE {`_.,� ! ,, i � __ . l ` , ... 1 a� Reinforced cell prevents potential induced degradation i. ,_,.„,„„.„,_ Module Type JKM305M-60L JKM310M-60L JKfd1315M-60L JKM320M-60L JKM325M-60L t SIC NOCT SIG N001 SIC NOCT STC NOCT SCC NOCT 'r 1Jr---------- -- , Beffer Low-Light Performance. Maximum Power(P max) 305Wp 227Wp 310Wp 231Wp 315Wp 235Wp 320Wp 239Wp 325Wp 242Wp - Excellent performance in low-light environments Maximum Power Voltage(Vmp) 328V 30.8V 33.0V 31.0V 33.2V 31.2V 334V 31.4V 33.6V 31.6V Maximum Power Current(Imp) 9.30A 7.40A 9.40A 7.49A 9.49A 7.56A 9.59A 7.62A 9.68A 7.66A .l --.._- FIL4 Strength and Durability Open ci curt`Va tape(Voc) 40.3V 37 211 40,SV 37.4V 407V 3T.6V 40:9V 37.8V 4t.1V 38.OV -t---”.` ? - Certified for high snow(5400Pa)and wind(2400 Pa)loads Shot c cut Cu•rent(Isc) 9.83A 8.12A 9.92A 8.20A 10.04A 8.33A 10.15A 8.44A 1020A 8.54A -1----:1----' Module Efficiency SIC(%).:... 10.28'%;, '15.55% 18.86% 19,1891, 19,4894 . 1 - 1 Operas ng Temperature('C) -40°C-+85°C 1 Weather Resistance ' { } Certified for salt mist and ammonia resistance Maximum System Voltage. 1000VDC(UL)It000Vf9CQEC).: t Maximum Series Fuse Rat.ng 20A a�,"+a•, (� --�"'-- Power Tolerance 0.-+39f;. Temperature Coefficients of Pe -0.37 ,/°C 'n •IS09001 2008 Quality Standards Temperature Coefficients of Vac -0.28%IC •17014001 2004 Environmental StandardsLINEAR IN PERF t A Temperature Coefficients of Isc 0.048%PC .OHSAS13001 Occupational Health&Safety Standards 45±2°C Year Product Warranty• 25 Year Linear Power Warranty Nominal Operating Cell Tem erature (NOCT)IEC61215,IEC61730 certified products ,... • UL1703 certified praducts Nomenclature Linear performance warranty 100% Standard performance f- c aJKM325Mne�6UBr Code Cell Q 9� doonarvrti�yo �� STC cirradiance 1000W/m' ;Cell Temperature 25°C AM=1.5 ko 5 elsd; null Nam a�ntl ° � ���r„t�neW < t d�arr NOCT: Irradiance 800WJm� Ambient Temperature 20°C � AM=1.5 Wind Speed lm/s a � �� �r g o so.2ss- "'”liittitViiii "'`- " Power measurement tolerance:±3% C(121�s CE a NAME LISTED ,r�r�, 12 years sHEETDATA SHEET CAUTION:READ SAFETY AND INSTALLATION INSTRUCTIONS BEFORE USING THE PRODUCT. Of Jinko Solar Co., Ltd.All rights reserved.Specifications included in this datasheet are subject to change without notice. JKM305-325M-60L-A1-US PAGE NUMBER REVISION DS 0 FCASI ED P11 04 -11A UN IAC d�l@lil!�ER/ NCL SUR 1220 S.630E STE.430 AMERICAN FORK,UT 84003 Basic Features 800-377-4480 • Stamped SneaEmless Construction WWW.BLUERAVENSOLAR.COM • 8 Gauge Galvanized Steel �; y CONFIDENTIAL-THE INFORMATION �f �+ C • r owder \coated SU1 faces ,- HEREIN CONTAINED SHALL NOT BE • !, USED FOR THE BENEFIT OF • Flashes into the coo deck ANYONE EXCEPT BLUERAVENSOLAR NOR SHALL IT • 3 ROQf deck IC11OC�COUtS .�J .��J , BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE , eck .„...,..,,„, .„,,. ., . , , ..... .. „„,,,..:_.,,,..„. , ,.,, .., . ,,._:., ,, ,,,...„.,,,,.....,,,,,.. Lu • Centering dimples for entrylexit RECIPIENTS ORGANIZATION, ,, . D fittings or conduit EXCEPT IN CONNEC TION WITH THE SALE AND USE OF THE RESPECTIVE • Position Ground lug Installed EQUIPMENT,WITHOUTTHE WRITTEN PERMISSION OF cL • Mounting Hardware Included BLUERAVENSOLAR LLC. SolaDeck Model SD 0783 } �— • O l/ cr W O co SolaDeck UL5a Type 3R Enclosures (9z H O N \ QcLrn UOQ 4 Available Models: co z r d" ¢ d q HWco � ��_ Model SD 0783 (3"fixed Din Rail) E— O \\\.,x.: � Model SD 0786 (6"slotted Din Rail) f-- o Z J SolaDeck UL 1741 CombineriEnciosures CO Models SD 0783-41 and SD 0786-41 are labeled and ETL listed UL STD 1741 according to the UL STD 1741 for photovoltaic combiner enclosures. Max Rated 600VDC, 120AMPS ` Model SD 0783-41 3°Fixed Din Rail fastened using No. System � /i sa0/ ' Typical System Configuration �.. , 4-Din Rail Mounted Fuse Holders 6001:D—come 30 AMP 1 Power Distribution Block 600VDC 175AMP 1-Bus Bar with UL lug Model SD 0786-41 6"Slotted Din Rail fastened using steel studs *"Typical System Configuration 4 Din Rail •Mounted Fuse Holders 600VDG 30 AMP 4-Din Rail Mounted Terminal Bloeks Bus Bars with UL lug /� "Fuse holders and terminal blocks added in the field must be UL listed or \\\\\\\ \ ji 9 \\ reco cognize and meet fi00 VDC 30 AMP y 1 � ��`y\V�� 1100 for fuse holders,600V 50 AMP © V '� !� �A`�\ " \\\�` 90C for rail mounted terminal blocks \�v A i � , , � and 600 V 175 AMP 90C for Power - Distribution Blocks, Use Copper Wire �� Conductors. �� Cover is trimmed to allow Model SD 0783-a1,wired with Model SD 0786-41,wired with conduit or fittings,base is Din Rail mounted fuse holders, Din Rail mounted fuse holders, center dimpled for fitting bus bar and power distribution terminal block and bus bars. locations. block. SHEET NAME RSTC Enterprises, Inc •• 2219 Heimstead Road•Eau Cliare, WI 54703 DATA SHEET For product information call 9(866) 367-7782 PAGE NUMBER REVISION DS 0 '''%) --. N f 'I SUN E R N I, -7i BLUE RAVEN lin - '- I ---- FRAME sysT ml BONDING & G OuNDI GI ,, I 1220 S.630E STE.430 1 ii' INSTALLATION GUIDE : PAGE AMERICAN FORK,UT 84003 ri: g ri*a0 M I I iggg.gi M gig' 800-377-4480 WWW.BLUERAVENSOLAR COM MI_..__---.- _— I mo ' ... ± '"',. 4 11 a..,,_....,..,.�___.__ _ CONFIDENTIAL-THE INFORMATION 4 ��■ • I HEREIN CONTAINED SHALL NOT BE ' `� ' USED FOR THE BENEFIT OF Tkiry..: 3 ANYONE EXCEPT WI BLUERAVENSOLAR NOR SHALL IT I♦MI INN w. BE DISCLOSED IN WHOLE OR IN 111111 IIIIII PART TO OTHERS OUTSIDE NM MIMI RECEXCEPTPIENTS IN CONNECOTION WITHOTHE 11111 ■' I SALE AND USE OF THE RESPECTIVE .../.,c,. EQUIPMENT,WITHOUT THE maim 1 g ' - di, II ., — .> BLUERAVENSOLAR LLC ,' WRITTEN PERMISSION OF % MEN MIMI i zccrn Qom - : 11111111 Mill W, � . I _ _ c� -. [ ��,., �i E-W BONDING PATH:E-W module to module bonding2i_ H > ao cc) 0 f . A® is accomplished with 2 pre-installed bonding clips v O 0 < rill I which engage on the secure side of the MicrorailTMMINN NOM v w and splice. 0 D � m Star Washeris r 0°Ot 11 Single Use Only Sing,,,as„ holy TERMINAL.TORQUE, Install Conductorand ,�°u, kit torque to the fo i : TERMINAL TORQUE, TERMINAL T R ,U , `4`0 4-6 AWG:35in-lbs install Conductor ann Install Conductor and -4 S MG:25 Innlbs torque to the fot i. °# : torque to the following: 1100111 C-N;;INNI” 10-14 AWG:20 in44hs 44 AWS: 35in Los 6-14 AW-. 7tt-lbs N-S BONDING PATH: N-S system bonding is LUG IL & TOR UE INFO LUG DETAIL & TORQUE INFO LUG E IL & TORDUE INFO accomplished through a N-S bonding clip.Insert each Tisco Lay-In Lug (GBL-4DBT) Tisco Flange Lug(SGB-4) Wiley WEEBLug (6.7) end of the N-S bonding clip onto a module frame • 10-32 mounting hardware • 1/4" mounting hardware • 1/4" mounting hardware flange. System is ., _ .e s with a sI g, a � ,:, • Torque = 5 ft-lb • Torque = 75 in-lb • Torque = 10 ft-lb - oeer it is recommended that N-S bonding clips • AWG 4-14-Solid or Stranded • AWG 4-14-Solid or Stranded • AWG 6-14-Solid or Stranded be installed Oil both edges for ease of a ai tenance NOTE: ISOLATE COPPER FROM ALUMINUM CO TACTTO PREVENT CORROSION (see also: in hew. ...,,. Page S) System bonding is accomplished through modules. System grounding accomplished by attaching a ground lug to any module SHEET NAME DATA SHEET at a location on the module specified by the module manufacturer. PAGE NUMBER REVISION DS 0 Intertek AUTHORIZATION TO MARK BLUE RAVEN This authorizes the application of the Certification Mark(s) shown below to the models described in the Product(s) 1220 S.630E STE 430 Covered section when made in accordance with the conditions set forth in the Certification Agreement and Listing i AMERICAN FORK,UT 84003 Report. This authorization also applies to multiple listee model(s) identified on the correlation page of the Listing i 800-377-4480 Report. i WWW.BLUERAVENSOLAR.COM CONFIDENTIAL-THE INFORMATION This document is the property of Intertek Testing Services and is not transferable. The certification mark(s) may be HEREIN CONTAINED SHALL NOT BE applied only at the location of the Party Authorized To Apply Mark. USED FOR THE BENEFIT OF ANYONE EXCEPT , „, �v. > > , o: �, �.�.. � o �., _� ko.o,,. BLUERAVENSOLAR NOR SHALL IT BE DISCLOSED IN WHOLE OR IN PART TO OTHERS OUTSIDE Applicant: Unirac, Inc Manufacturer: Jiaxing Pacific EnergyEquipment Corp• RECIPIENTS ORGANIZATION, EXCEPT IN NNEC TION WITH THE No. 8 Haiwan Ave SALE AND USE I OF THE RESPECTIVE 1411 Broadway Blvd NE Hangzhou Bay Bdao New Area EQUIPMENT,WITHOUT THE Address: Address: WRITTEN PERMISSION OF Albuquerque, NM 87102 Haiyan Economic Development Area BLUERAVENSOLAR LLC. Jiaxing City, Zhejiang Province Country: USA Country: China >- p ± ct s Klaus Nicolaedis Lili Zeng 0 Z 1(1Contact: Contact: Jason Mayfield George Huang Z rn UQ O I` 505-462-2190 510-979-1920 < 0 'r c Z M Phone: Phone: 505-400-2949 650-799-7627 ~ uS I— W o FAX: NA FAX: NA H O co o < co klaus.nicolaedis@unirac.com Izeng@ccmfg.com LL! U U IY Email: jasonm@unirac.com Email: george@ccmfg.com 0 D CC -J Party Authorized To Apply Mark: Same as Manufacturer 11 m Report Issuing Office: Lake Forest, CA Control Number: 5003278 Authorized by: ' for Dean Davidson, Certification Manager LIS u . Intertek This document supersedes all previous Authorizations to Mark for the noted Report Number. This Authorization to M ark isfor the exclusive use of Intertek's Client and is provided pursuant to the Certification agreement between Intertek and its Client.Intertek's responsibility and liability are limited to the terms and conditions of the agreement.Intertek assumes no liability to any party,other than to the Client in accordance with the agreement,for any loss,expense or damage occasioned by the use of this Authorization to Mark.Only the Client is authorized to permit copying or distribution of this Authorization to Mark and then only in its entirety.Use of Intertek's Certification mark is restricted to the conditions laid out in the agreement and in this Authorization to M ark.Any further use of the I ntertek name forthe sale or advertisement of the tested material,product or service must first be approved in writing by Intertek.Initial Factory Assessments and Follow up Services are for the purpose of assuring appropriate usage of the Certification mark in accordance with the agreement,they are not for the purposes of production quality control and do not relieve the Client of their obligations in this respect. Intertek Testing Services NA Inc. 545 East Algonquin Road,Arlington Heights, IL 60005 Telephone 800-345-3851 or 847-439-5667 Fax 312-283-1672 UL 2703 Issued: 2015/01/28 Ed: 1 Mounting Systems, Mounting Devices, Clamping/Retention Devices, Standard(s): and Ground Lugs for Use with Flat-Plate Photovoltaic Modules and Panels Photovoltaic Mounting System, Sun Frame Micro Rail- Installed Using Unirac Installation Manual, Rev Product: PUB2017FEB16 Brand Name: Unirac SHEET NAME Models: Unirac SFM DATA SHEET ATM for Report 102393982LAX-002 Page 1 of 2 ATM Issued: 2 Mar 2017 PAGE NUMBER REVISION ED 16.3.15(1-Jul-16)Mandatory DS 0 it • ■ TOOLS & ASSEMBLY DETAILS R'M MICROH IL iNsTALLATIoN Gli ■■ ti-� 4. L ma-- TECHNICAL DATA SHEET PAGE �' :a#x :.,. = atm. 4 w j ';r# 3�>a f .' ; s `r' t ; d: +.`f '` ss TOQLS RE UIREDfJR RECOMMENDED FOR 4. Min rP: y.kl"��,.. �.e*5+ r.:.#S . 1Y it ?'$;'qp �Y. as; ; \ ` ' •': ' 14.� .s r ,.. �. ,T v r UT&! LtATION; ..,0`''.- ; _ = # `' �:,` . "• , t rt `t IAYO NST ° 5....,,,-- „,,,,--...' f 1220 S.630 E STE,430 4 r a ' •TAPE MEASURE A #t ' '�” A i AMERICAN FORK,UT 84003 n -", { :m x, ,._� •CHALK LINE ' ' <>a ! a" *.' r. 800-377-4480 A 214 a *ROOFING CRAYON " -E p WWW BLUERAVENSOLAR COM erq F k .HAMMER e ., i ,=r - •COMPATIBLE SEAIANTAND DISPENSER cy CONFIDENTIAL-THE INFORMATION r ^.�'`g° $ 'a•4 .,, � �� aria s ", 44; �� HEREIN CONTAINED SHALL NOT BE � , .. s •DRILL WITH EITHERIJB BitfflRGRKANb „. :-`04:`:---',-','' .; /;a n£ � GAL e USED FOR THE BENEFIT OF itikt Y f; .UNiRAC CUSTOM STRUCTURAL SCREW,OR Tj32' ` �� a / Y ANYONE EXCEPT ''' F, .x a BIT FOR LAG BOLT , „ BLUERAVENSOLAR NOR SHALL IT ur f x,t A,aY r z ''..'n,,,.- HEX r `. :;` ,r" BE DISCLOSED IN WHOLE OR IN • 1 f x y •IMPACT DRIVER WITHK'SOCKET(OPTIONAL/T stt '..e.:,.,-4i, ,`'t 3 VC-4,,, t ° + u k^ iT {+ ". ° HEX DRIVER FOR UNIRAC CUSTOM STRUCTURAL .- RE RIP EO OTHERS OUTSIDE ''t.4 �rd¢ k . �,' "`*. '''''''-''--'-n.;';',;')' C SO G TION, r a, s g�_ SCREW; v + _ '� ; r y"moi - EXCEPT IN CONNEC TION WITH THE ''s >r' a 1,,c 0. 2'- SFM RAISED ti SEAL FLASHING COMFONENTS: SALE AND USE OF THE RESPECTIVE s ., ' "a, EQUIPMENT,WITHOUT THE p ` r t. < " , ° E •va. ®; I.FASTENER: WRITTEN PERMISSION OF aftAitIs s , •' *;{, Y t : *I. a. k * *'"! •PAG BOLT,5116' ` r" BLUERAVENSOLAR LLC. �`T ;�1w ,;,...;10...4f,....-‘,4 i��� {t° -.:**441 3 9�+°� ` _ ,*�� t '�`" - -UNIRAC CUSTOM STRUCTURAL SCREW,5/16` �y y �'~"�^�� � "' , rr ,. • >'..;4 kk S,w'J '.�` : ...,e.. .4' fir,">$+l �t.5: t. . . '�. •GRK STRUCTURAL SCREW,s/16" a >t t:tt TABLE OF CONTENTS: PG INSTALLATION NOTES: in O cz to 2.5/16'ID EDPM SEALING WASHER Q Tools&Assemtily Details 1 A.It is not necessaryor advisable to use nails or other fasteners to secure the perimeter of the flashing. L� z J 3.SFM MOUNTASSEMBLY(VARIOUS}WITH SLIDER C, (— Quick Steps for Installation 2 B.The SFMRaised Seat Flashing is made to work with standard and high-definition composition/asphalt and z C CP Q [� A.SFM RAISED SEAL(LASHING wood shi to roofs with s'to S-S;&'courses. 7. S.COMP SHINGLE ROOF C.Mounts should not be installed in areas o#the roof susceptible to ice damming.Ponding water can travel < z C ) upward under shingles and reach the bolt penetration. < H LO I- in C) D.Fastener length specification and capacity verification are the responsibility of the installer. O O Q W U U PUB2017JAN11 o L1J D CL m a ■ �x R QUICKINSTALLATION STEPS IN n „, iII:EAGGTI PAGE r � m ,, ' ',fir ~ r '� +\ '§r r V `` . x s k. rr"? sia - _44,141 A .' A ' »x.,�,^rq, «s 1} 6 2"Yom` F �' t � ., a x; >k ,u< PREPARING SHINGLES: Use roofing DRILL PILOT HOLES: Holding the drill ROOF SEALANT: Fill pilot hole with OPTIONAL SEALANT ON FLASHING: bar to break seals between 1st and square to the rafter,drill 5'deep pilot appropriate sealant. Apply a circle shaped bead of sealant 2nd,and 2nd and 3rd shingle courses: hole into center of rafter using 1/8" around the attachment hardware hole Be sure to remove all nails to allow aircraft extension bit for 5/16"GRK of the flashing before insertion. Do correct placement of flashing.See S. or Unirac Custom Structural Screw,or. not use excessive sealant installation guide for proper flashing 7/32'aircraft extension bit for 5/16" placement. lag. ,,,;:t..„k,.71t,,riciit.1",,,t7.„;: ,,,,f,tii;14::::41:t.:, POSITION FLASHING: Slide the PLACE SLIDER: Place slider with INSTALL FASTENER & TIGHTEN: COMPLETE FLASHING INSTALLATION: flashing upunderneaththe2ndcourse assembly over the flashing flute, Install fastener with sealing washer. Repeat previous steps to install all of shingles,so that the bottom edge ensuring that the slider sits flat on the Swivel the slider to gauge proper mounts. of the flashing does not overhang the flashing surface. torque when driving the fastener. downslope edge of the 1st course of Tighten until slider stops swiveling SHEET NAME shingles. easily. DATA SHEET PAGE NUMBER REVISION DS 0