Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (136)
[v / ,., 12570 SW 69th Ave Push/Pull of 4 ton RTU. g.....• I ...., I I Z$t t Y //NJ VMI I i I n A I I i .. George Fox AM ........ +... o nseling 4. 41.V1„71, Ell c gs.., cob: .. Ur ?J.r�.^rnr� U ► r s F<rmers s r 1111Z _"" .fir-.. '� 42611k -, / ---.. i i..' I . ; � - � I - Google t , ------- - ___ _ Imagery ©2019 Google, Map data ©2019 Google 5 m RECEIVEDIV Location: George Fox University Scope of Work: 12570 SW 69th Ave. 1. Push/Pull of a 4 ton RTU. MAY 7 201 Portland, OR 97223 CITY OF TIGARD BUILDING DMSIO OFFICE COPY THE ACTIVATION OF A DUCT CITY OF TIGARD SMOKE DETECTOR SHALL REVIEWED FOR CODE COMPLIANCE ACTIVATE A VISIBLE AND AUDIBLE SUPERVISORY Approved: I SIGNAL AT A CONSTANTLY OTC: [ ATTENDED LOCATION Permit#: me,Can V c)-00 a$6 OMSC 606.4.1 Address: I AAS 1 nc.;w 69-A Au Suite #: By: 582J GAS HEAT/ELECTRIC COOLING bryant SINGLE PACKAED ROOFTOP 14 SEER st 3 TO 5 NOMINAL TONS Heating&Cooling Systems G Product I: ata :,_,, TEGACYTM INE L 582KJO5A090A2AOAC i I I-,E { \(, 7773 ;rk I i k � C08515 (Shown with optional Louvered Hail Guard) DSHRILE PuronCOCIfIPLIANT TABLE OF CONTENTS • • PAGE PAGE FEATURES AND BENEFITS 3 APPLICATION DATA 19 MODEL NUMBER NOMENCLATURE 4 COOLING TABLES 21 FACTORY OPTIONS AND/OR ACCESSORIES .. . . . 5 STATIC PRESSURE ADDERS 27 AHRI COOLING RATING TABLES 8 FAN PERFORMANCE 29 HEAT RATING TABLE 8 ELECTRICAL INFORMATION 36 SOUND PERFORMANCE TABLE 9 SEQUENCE OF OPERATION 42 PHYSICAL DATA 11 GUIDE SPECIFICATIONS 42 CURBS &WEIGHTS DIMENSIONS 14 bryant Heating& Cooling Systems The Bryant rooftop unit (RTU) was designed by customers for customers. With "no-strip screw" collars, handled access panels, and more we've made your unit easy to install, easy to maintain and easy to use. Easy to install: All Legacy Line" units are field-convertible to horizontal air flow which makes it easy to adjust to unexpected job site complications. Lighter units make easy replacement. Bryant 582J rooftops fit on existing Bryant curbs dating back to 1989. Also, our large control box gives you room to work and room to mount Bryant accessory controls. Easy to maintain: Easy access handles by Bryant provide quick and easy access to all normally serviced components. Our "no-strip" screw system has superior holding power and guides screws into position while preventing the screw from stripping the unit's metal. Take accurate pressure readings by reading condenser pressure with panels on. Simply remove the black, composite plug, route your gauge line(s) through the hole, and connect them to the refrigeration service valve(s). Easy to use: The newly designed, central terminal board by Bryant puts all your connections and troubleshooting points in-one convenient place, standard. Most low voltage connections are made to the same board and make it easy to find what you're looking for and easy to access it. Bryant rooftops have high and low pressure switches, a filter drier, and 2-in (51mm) filters standard. . FEATURES AND BENEFITS • Single cooling stage models • SEER up to 14.1. • EER's up to 12.0. • Up to 28% lighter than similar industry units. Lighter rooftops make easier replacement jobs. • Utility connections are the same because 3 - 5 ton units fit on existing Bryant rooftop curbs. This saves time and money on replacement jobs. • Standardized components and layout. Standardized components and controls make service and stocking parts easier. • Scroll compressors on all units. This makes service, stocking parts,replacement, and troubleshooting easier. • Field convertible airflow. Being able to convert a unit from vertical airflow to horizontal makes it easy to overcome job site complications. • Standard Direct Drive - ECM indoor motor with optional belt drive system to meet nearly all applications. • Provisions for bottom or side condensate drain. • Capable of thru-the-base or thru-the-curb gas line routing. • Single-point gas/electrical connection. • Sloped, composite drain pan sheds water; and won't rust. • Standardized controls&control box layout. Standardized components&controls make stocking parts& service easier. • Tool-less filter access door. • Clean, large, easy to use control box. • Color-coded wiring. • Large,laminated wiring and power wiring drawings which are affixed to unit make troubleshooting easy. • Single, central terminal board for test and wiring connections. • Fast-access, handled, panels for easy access on normally accessed service panels. • "No-strip" screw system guides screws into the panel &captures them tightly without stripping the screw, the panel, or the unit. • Mechanical cooling(115°F to 40°F or 46°C to 4°C)standard on all models.Winter Start Kit allows cooling operation down to 25°F(-4°C)and MotorMaster to -20°F(-29°C). • High efficiency, gas heat with induced-draft flue exhaust design. • Induced draft motor ensures no flue gas can escape into the indoor air stream. • Bryant designed naturally draining heat exchanger, unlike positive pressure heat exchangers, do not need to be periodically, manually drained. This saves labor and maintenance expense. • 2-in (51mm)disposable filters on all units. • Refrigerant filter-drier on each circuit. • Each circuit is protected with a high and low pressure switch. • Many factory-installed options ranging from air management economizers, 2 position dampers, plus convenience outlets, disconnect switches and smoke detectors. • Standard (parts only)Warranty: 15 yr. Stainless steel, 10 yr. aluminized heat exchanger, 5 yr. compressor, 1 yr.parts. • Factory-installed Perfect Humidity" dehumidification system on all sizes, includes MotorMaster I controller. 3 MODEL NUMBER NOMENCLATURE . Position: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Example: 5 8 2 J E 0 6 A 0 7 2 A 0 B 0 A A Unit Type Packaging and Control 582-Gas Heat RTU,Legacy Series A= Standard Packaging,electro mechanical controls that require W7212 EconoMi$er IV Model B = LTL Packaging,electro mechanical J - Puron®(R-410A)Refrigerant controls that require W7212 EconoMi$er IV C= Standard Packaging,electro mechanical controls that require W7220 EconoMi$er X Voltage F = LTL Packaging,electro mechanical E = 460-3-60 controls that require W7220 EconoMi$er X J = 208/230-1-60 P = 208/230-3-60 T = 575-3-60 Factory Installed Options OA =None NOTE:See the 582J 3 to 5 ton Price Pages Cooling Tons for a complete list of factory installed 04- 3 tons options. 05- 4 tons 06- 5 tons Outdoor Air Options A= None Refrig.System/Gas Heat Options B = Temperature Economizer,Barometric Relief, A= Standard One Stage cooling models/Nat.Gas Heat Standard Leak(W7212 or W7220) B = Standard One Stage cooling models/Low NOx Heat E = Temperature Economizer,Barometric Relief, C= Standard One Stage cooling models/SS HX Heat Standard Leak w/CO2(W7212 or W7220) G= One-Stage cooling models/Alum Heat Exchanger H= Enthalpy Economizer,Barometric Relief, with Perfect Humidity TM Standard Leak(W7212 or W7220) H = One-Stage cooling models/Low NOx Heat L = Enthalpy Economizer,Barometric Relief, with Perfect Humidity Standard Leak w/CO2(W7212 or W7220) J = One-Stage cooling models/Stainless Steel Exchanger Q= Motorized 2 Position Damper with Perfect Humidity U= Temperature Economizer,Barometric Relief, Ultra Low Leak(W7220) Heat Level Input W= Enthalpy Economizer,Barometric Relief,Ultra Low Leak Standard/Stainless Steel (W7220) 072 =72,000 115 =115,000 Indoor Fan Options 150 = 150,000 0 = Direct Drive ECM Low NOx 2 = Medium Static Option 060 =60,000 3 = High Static Option 090 =90,000 120 =120,000 Coil Options(RTPF)(Outdoor-Indoor-Hail Guard) A= Al/Cu-Al/Cu B = Precoat Al/Cu-Al/Cu Note:On single phase(-J)voltage code)models,the C= E-coat Al/Cu-Al/Cu following are not available as a factory installed option: D= E-coat Al/Cu-E-coat Al/Cu -Perfect Humidity E= Cu/Cu-Al/Cu -Coated Coils or Cu Fin Coils F = Cu/Cu-Cu/Cu -Louvered Hail Guards u-Al/Cu—Louvered Hail Guard -Economizer or 2 Position Damper N= Precoat Al/Cu-Al/Cu—Louvered Hail Guard -Powered 115 Volt Convenience Outlet P = E-coat Al/Cu-Al/Cu—Louvered Hail Guard Q= E-coat Al/Cu-E-coat Al/Cu—Louvered Hail Guard R= Cu/Cu-Al/Cu—Louvered Hail Guard S = Cu/Cu-Cu/Cu—Louvered Hail Guard C 14337 MINI ._ • • NOTES: UNITED :;:..::;.7 1X15 DOCUMENI IS THE PROPERTY 01 CARRIER CORPORATION SUUNIS510R O!TREED DRAWINGS OR DOCUMENTS 1. DIMENSIONS ARE IN INCHES, DIMENSIONSrY TECHNOLOGIES ARD IS EIIIVIRID UPON IRE ERPRISS CONDITION THAT RRI DOES X01 CONSTITUTE PART PERFORMANCE OR IN[ 1 ARE IN MILLIMETERS. UNIT J K Di PHASE) K (3 CARRIER 13221 CORPORATIONS WRIIIIMDCONSE XTD OR USED WITHOUT CARRIER ACCEPTANCE OF CONTRACT. 5821 04 33 3/8 14 7/8 14 7/8 2. O CENTER OF GRAVITY (847] 13111 13771 5821 OS 33 3/8 14 7/8 18 5/8 CONNECTION SIZES 3. DIRECTION OF AIR FLOW [8471 13111 [4721 A 13/8' 1351 DIA FIELD POWER SUPPLY HOLE 5821 06 41 3/8 14 7/8 18 5/8 11051] [317] [4721 B 2' 150] DIA POWER SUPPLY KNOCKOUT C 1 3/4' 1511 DIA GAUGE ACCESS PLUG D 7/8' 1221 DIA FIELD CONTROL WIRING HOLE 33-3/8 18481 E 3/4'-14 NP7 CONDENSATE DRAIN F 1/2'-14 NPT GAS CONNECTION D ' G 2 1/2 " 1641 DIA POWER SUPPLY KNOCK-OUT 32.1/4 - T ECONOMIZER HOOD [8181 (OPTIONAL) 16 14061 FILTER ACCESS PANEL I iHRU-iNE-BASE CHART l l STOOL-LESS) CORP. THESE HOLES AEOUIRED FOR USE • • • ACCESS R CONDENSER •PANEL COIL CRBTMPWROOIA01, 003A01 �� • I THREADED WIRE REO'D HOLE �RR� t INDOOR COIL „,...50.....„....:,_ ^� "`'• ' - + CONDUIT SIZE USE SIZES (MAX.) ACCESS PANEL yWy 7I W I/2' ACC. 7/8' 122.21 Vd O I �- 25-5/8 -- 10-7/8 *II I vt' 24V 7/8' [22.21 c ,49.. 16521 1277] Y « 3/4^ 1001,0031 POWER 1 1J8' [28.A] — RETURN AIR _ RETURN[441117] • AIR Z•* (003) 1/2" GPT GAS 1 3/16' 130.01 25/8FOA "THRU-THE-BASEPAN' FACTORYE OPTIONBACK 1677 FITTINGS FOR ONLY 9,0, 0 Z ARE PROVIDED t.il TOPF •�'�' E ALT. i A SELECT EITHER 3/4"OR I/2' / I III CURB 'W • CONDENSATE 17.3/4 FOR POWER, DEPENDING ON WIRE SIZE WIDTH I ' DRAIN OPENING 14511 NN 'Y IN BASEPAN 29-3/8 II� 10011 PROVIDES 3/4' FPi THRU CURB 1 SUPPLY 26.112 FLANGE d FITTING. 18.1/8 •Z AIR 16731 17471 SUPPLY 14591 AIR at, 16-1/8 14-1/d 12-1/4 _ N4 [411] [3631 13121 SEE THRU THE ••• 6-1/4 - GH II I y BASE CHART 1157CA I ' 3-3/8 Po EFLUE 12-1/8 [85] 25 L 4 HOOD 13071 ii: -� H 1636] —_ 11001 TOP 18-1/1 FSI 4-5/8 A701 [118] (12.112 N�RWNE [2651 1-1/4 l J 132] ELECTRICAL F DISCONNECT • r ., ELOCATION CONDENSER �I CONTROL BO% INDOOR BLOWERCOIL E STD. , FILTERACCESS PANEL ACCESS o CONDENSATE. DRAIN 25.1/8 Fy[638] L-1OPTIONAL � 1 AETURN OUTSIDEFACTORY =_ . 9-1R OPTIONAL _ HANDLE 11'3/8 SUPPLYAI� AIRA1� �] INSTALLED [4941 FACTORY CONVENIENCE =W INSTALLED ——— [2891 OUTLET _= DISCONNECT ——— _ 21-1/4 65/8 • [5391 • I 11551 R>_— 3-3/4 I HANDLE L 8-3/8 --6-5/8— E 7 t 6 1 [951 46-3/4 - 30-1/8 12131 [169] 11771 521 I11871 f764I 26.7/8 74-3/8 16821 BAROMETRIC [18881 31-I/4 RELIEF LEFT RETURN[193] FLOW FRONT SUPPLr AIR T RIGHT "IR SHEET DATE SUPERCEDES 582J 04-06 SINGLE ZONE ELECTRICAL REV t Ort 08-14-14 - COOLING WITH GAS HEAT 48KC000284 _ o A N J O �y�``wI'`''�i' UNITED P.O.BOA 1808 THIS DOCUMENT IS THE PROPERTY OF CARRIER CORPORATION SUBMISSION Of THESE DRAWINGS OR DOCUMENTS "W L TECHNOLOGIES SYRACUSE.Nv AND IS DELIVERED UPON THE EUPRESS CONDITION THAT THE DOES SNorIO CONSTITUTE PART PERFORMANCE OR STD. UNIT CORNER CORNER CORNER CORNER V CARRIER 13221 CONTENTS WILL NOT IE DISCLOSED OR USED WITHOUT CARRIER ACCEPTANCE El CONTRACT UNIT WEIGHT WEIGHT (A) WEIGHT (81 WEIGHT ICT WEIGHT IN C.G. HEIGHT CORPORATION'S WRITTEN coxs[xl. LBS. KG. LBS. KG. LBS. KG. LOS. KG. LAS. KG. N 1 2 582J 04 490 222 120 54 111 50 125 56 135 61 35 3/4 19081 24 3/4 16281 18 7/8 14791 582J 05 544 246 130 58 126 57 142 64 146 66 36 3/4 E9334 24 3/4 [6281 18 7/8 14791 582J D6 597 270 141 64 156 70 158 71 142 64 39 1/8 19931 23 1/2 1597] 20 1/8 15111 w STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B 1 I(` i\ . 9. 4, *11 N [ Cil y 3* il . . . CA 16.4 CORNER D CORNER C P`� A % F� TOP O .. z N ~ O N z . : =_i n =c CI FRONT ,, SHEET DATE SUPERCEDES 582J 04-06 SINGLE ZONE ELECTRICAL REV 2oF2 08-14-14 COOLING WITH GAS HEAT 48KC000284 - A N J 582J . , . . 14V PACKAGE GAS / ELECTRIC/0,/ ROOFTOPm G A ,, � FORM NO.R11-835 REV.7 ° Supersedes Form No.Ri 1-835 Rev.6 RKKA- NOMINAL SIZESSTANDARD 3-7.5 TONSEFFICIENCY[10.6-26.SERIES4 kW] (3 PHASE ONLY) RKMA- R NOMHIGHINAL SIZESEFFICIENCY 6 TON [21SE.1 kWIESJ (3 PHASE ONLY) m r -�% ":1. 'r 74' Z ��¥; .�.,.> '- +� sus x. 0n yz 3 F A (r-,‘ ‘'''" t''''` (--- cle ,� C (ii) us 1 LISTED 1 . TABLE OF CONTENTS e4 'pm : , „....._ , 4 '. "AlAll 0# Engineering Features 3 Introduction 4 Selection Procedure 5 Model Identification Options 6-9 General Data RKKA- Series 10-33 RKMA- Series 34-36 General Data Notes 37 Performance Data RKKA-Series 38-40 RKMA- Series 41 Airflow Performance i RKKA-/RKMA-Series 42-50 Electrical Data RKKA- Series 51-56 RKMA- Series 57-58 Dimensional Data 59-64 Accessories 65-74 Typical Wiring 75-80 Limited Warranty 82 MODEL IDENTIFICATION—RKKA/RKMA- SERIES jeem 1trt0'-",'-„4I'',,t1's'.,...`;,54„•,•4-„l"V"",,.-4,4:.i4„.1;;,4i.V.;,'i,%';''4a'v„,<'',i.2',c.,-i.4,/,.4',l,,1l-;',4it.,I:,''t'-v.i`i,,..'...l4‘t'If'k$6,'','.: R KKA - A03& CK08E XXX LEconomizer Option(See Next Page) ,* Factory Installed Options (See Next Page) Ignition System ] E=Elecric Ignition, 1 Stage Gas Valve,NOx 1 X=Electric Ignition, '' = 1 Stage Gas Valve T=Electric Ignition,Two-Stage Gas Valve(A085 Only) O. Heating Capacity(MBH) 08= 80,000[23.5] 10=100,000[29.3] 12=120,000[35.2l13: 350039.6 13=135,000[39.6] Drive Package K=Direct Drive L=Belt Drive M=Belt Drive—High Static Electrical Designation C=208-230 V,3 PH,60 Hz 0=460 V,3PH,60Hz Y=575 V,3PH,60Hz ,, Cooling Capacity(BTUH)[kW] 036136,000110:551042 36=36,000[10.55] 042=42,000[12.31] 048=48,0: 1I4 48,000[14.07] 060160:0158 00[ 7. ] 072=72 72 72000[21.10] 073=7200 [21101 73 72,000[21.10] 085 85,000[24.91] Future Technical Variations Design Series A=1st Design Efficiency Designation K=Standard Efficiency(10 SEER) ASHRAE 90.1-1989 Compliant M=High Efficiency(12 SEER) EnergyStar Compliant Product Classification K=Rooftop—Commercial Tradebrand R=Rheem Package Gas/Electric Nii ]Designates Metric Conversions 6 GENERAL DATA-RKKA- SERIES teem i NOM. SIZES 3-7.5 TONS [10.6-26.4 kW] ASHRAE 90.1-1999 COMPLIANT MODELS Model RKKA-Series A048DM10E A048DM13E A048JK08E A048JKO8X Cooling Performance1 CONTINUED--4.- Gross ►Gross Cooling Capacity Btu[kW] 50,000[14.6] 50,000[14.6] 50,000[14.6] 50.000[14.6] EER/SEER2 9,8/10.4 9.8/10.4 9.8/10.4 9.8/10.4 Nominal CFM/ARI Rated CFM [L/s] 1600/1600[755/755] 1600/1600[755/755] 1600/1600[755/755] 1600/1600[755/755] ARI Net Cooling Capacity Btu [kW] 48,000[14.1] 48,000[14.1] 48.000[14.1] 48,000[14.1] Net Sensible Capacity Btu[kW] 35,500[10.4] 35,500[10.4] 35,500[10.4] 35,500 [10.4] Net Latent Capacity Btu [kW] 12,500[3.7] 12,500[3.7] 12,500[3.7] 12,500[3.7] Net System Power kW 4.9 4.9 4.9 4.9 Heating Performance(Package Gas/Electric)Q Heating Input Btu[kW] 100,000[29.3] 135,000[39.6] 80,000[23.4] 80,000[23.4] Heating Output Btu[kW] 81,000[23.7] 109,400[32.1] 62,500[18.3] 62,500[18.3] Temperature Rise Range°F[C] 30-60[16.7/33.3] 50-80[27.8/44.4] 30-60[16.7/33.3] 30-60[16.7/33.3] AFUE% 80 80 80 80 Steady State Efficiency(%) 81 81 78.5 78.5 California Seasonal Eff. (%) NA NA 75.5 75.5 No.Burners 5 6 4 4 No.Stages 1 1 1 1 Gas Connection Pipe Size in.[mm] 0.5[12.7] 0.5[12.7] 0.5[12.7] 0.5[12.7] Compressor No./Type 1/Scroll 1/Scroll 1/Scroll 1/Scroll Outdoor Sound Rating(dB)5 78 78 78 78 Outdoor Coil-Fin Type Louvered Louvered Louvered Louvered Tube Type Smooth Smooth Smooth Smooth Tube Size in.[mm]OD 0.375[9.5] 0.375[9.5] 0.375[9.5] 0.375 [9.5] Face Area sq.ft.[sq.mj 16.91 [1.57] 16.91 [1.57] 16.91 [1.57] 16.91 [1.57] Rows/FPI[FPcm] 1/18[7] 1/18[7] 1/18[7] 1/18[7] Indoor Coil-Fin Type Louvered Louvered Louvered Louvered Tube Type Smooth Smooth Smooth Smooth Tube Size in. [mm] 0.3125[7.9] 0.3125[7.9] 0.3125[7.9] 0.3125[7.9] Face Area sq.ft.[sq.m] 5.17[0.48] 5.17[0.48] 5.17[0.48] 5.17[0.48] Rows/FPI[FPcm] 4/13[5] • 4/13[5] 4/13[5] 4/13[5] Refrigerant Control Capillary Tubes Capillary Tubes Capillary Tubes Capillary Tubes Drain Connection No./Size in. [mm] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4] 1/1 [25.4] Outdoor Fan-Type Propeller Propeller Propeller Propeller No. Used/Diameter in.[mm] 1/24[609.6] 1/24[609.6] 1/24[609.6] 1/24[609.6] Drive Type/No.Speeds Direct/1 Direct/1 Direct/1 Direct/1 CFM [L/s] 4000[1888] 4000[1888] 4000[1888] 4000[1888] No.Motors/HR 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP 1 at 1/3 HP Motor RPM 1075 1075 1075 1075 Indoor Fan-Type ' FC Centrifugal FC Centrifugal FC Centrifugal FC Centrifugal No.Used/Diameter in. [mm] 1/11x11 [279.4x279.4] 1/11x11 [279.4x279.4] 1/11x11 [279.4x279.4] 1/11x11 [279.4x279.4] Drive Type/No.Speeds BeltNariable BeltNariable Direct/3 Direct/3 No.Motors 1 1 1 1 Motor HP 3/4 3/4 1/2 1/2 Motor RPM 1725 1725 1725 1725 Motor Frame Size 56 56 48 48 Filter-Type Disposable Disposable Disposable Disposable Furnished Yes Yes Yes Yes (No.)Size Recommended in.[mm] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] (1)1x16x25[25x406x635] Refrigerant Charge Oz. [gI 106[3005] 106[3005] 106[3005] 106[3005] Weights Net Weight lbs. [kg] 573[260] 573[260] [260] 573[260] Ship Weight lbs.[kg] 580[263] 580[263] 580[263] 580[263] See Page 37 for Notes. [ ]Designates Metric Conversions 22