Plans (21) M EC2019 - 00070 \ (\ C.c 1Ok- Occ- ---() c)0- 9 St, 1r0c, Sh- SA . V 11 cic cci ti t Ac r RECEIVED FEB 6 2019 CITY Ut- la�RD PROJECT NOTES SHEET INDEX: ARCHITECT: 3UILDI 1G OI'flSl �I APPROVED PLANS SHALL NOT BE USED BY WORKMEN. THE GENERAL CONTRACTOR SHALL ENSURE ALL T1.1 TITLE SHEET •• •• •• •• •• DAVID SCOTT TRADES ARE USING MOST CURRENT SET OF CONSTRUCTION DOCUMENTS. ERRORS THAT RESULT FROM nnierisleep _ 1 THE USE OF OUT-DATED DRAWINGS ARE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. THE ARCHITECTURAL: WINDLE AIA GENERAL CONTRACTOR SHALL MAINTAIN ONE COMPLETE SET OF PLANS ON THE PREMISES IN GOOD -- - • - - -• - CONDITION AT ALL TIMES. THIS SHALL INCLUDE ALL ADDENDA AND CHANGE ORDERS. A0.1 ADA REQUIREMENTS THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO STARTING _ - A0.2 ADA REQUIREMENTS •• • 1431 GREENWAY DRIVE R _ SUITE 510 2 ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED `,M1 A0.4 FfNiSH, DOOR AND WINDOW SCHEDULES ® •• IRVING,Tx 75038 BY SUBCONTRACTORS AND OWNER. ALL DISCREPANCIES TO BE REPORTED TO ARCHITECT PRIOR TO START ;' PHONE 972.870.1288 OF CONSTRUCTION. ► 01.0 DEMOLITION PLAN ® E-MAIL scot# @idstudio4.com DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS, DRAWINGS AND SPECIFICATIONS ARE , a D1.1 DEMOLITION ELEVATION AND ROOF PLAN • • 3 NOT INTENDED. THE GENERAL CONTRACTOR IS TO CLARIFY ANY SUCH DISCREPANCIES WITH THE OWNERJ A1.0 DIMENSIONED FLOOR PLAN • • • •• PRIOR TO COMMENCING WORK AND COPY SAME CLARIFICATIONS REQUEST TO ARCHITECT. - • '' :I STATED DIMENSIONS TAKE PRECEDENCE OVER GRAPHICS, DO NOT SCALE DRAWINGS TO DETERMINE - - R y - ��, A1.1 NOTED FLOOR PLAN • • • • • 4 LOCATIONS. THE OWNER AND ARCHITECT SHALL BE NOTIFIED OF ANY SUCH DISCREPANCIES PRIOR TO _ , A1.3 FLOOR FINISHED PLAN • • • • • CONTINUING WITH WORK. II L IT SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR TO LOCATE ALL EXISTING UTILITIES - A1.4 REFLECTED CEILING PLAN • • • • • - 5 WHETHER INDICATED HEREIN OR NOT AND TO PROTECT THEM FROM DAMAGE. THE GENERAL CONTRACTOR A1.5 ENLARGED RESTROOM PLAN AND ELEVATIONS • +♦ 5 SHALL BEAR THE EXPENSE OF REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED A2.0 EXTERIOR ELEVATIONS AND DETAILS +♦ • ® ® • BY OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK. ` COcPORATE. GENERAL CONTRACTOR TO PROVIDE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NEPA 13 PER THE A2.1 INTERIOR ELEVATIONS • • • e • REQUIREMENTS OF SECTION 903.3.1.1 AND INDICATED HEREIN. FIRE SPRINKLER CONTRACTOR IS TO 9585 S 1Il!ASHINGTON SQUARE SPACE T11 A2.2 INTERIOR ELEVATIONS • • • ONE MALL GROUP •AMERISLEEP 6 SUBMIT COMPLETE SHOP DRAWINGS, LAYOUT AND RELATED DATA TO ARCHITECT/OWNER FOR APPROVAL • ` • • 7167 E. DR.,SUFrE 137 FIRST AND PRIOR TO SUBMISSION TO BUILDING DEPARTMENT AND FIRE MARSHAL FOR APPROVAL PRIOR A2.3 INTERIOR DETAILS SCOF.RANCHOALE, 85251., TO INSTALLATION. ANY REVISIONS TO SPRINKLER DRAWINGS AS A RESULT OF SUCH SUBMISSION SHAM 'II G A R D , OR. 97223FURTHER BE APPROVED BY OWNER PRIOR TO FABRICATION. 5P.1-]3_SPECIFICATIONS ® 0 • 485.4a6.3o's4 YJWW.AMERISf_EEP.COM GENERAL CONTRACTOR TO REFER TO THESE DOCUMENTS AS WELL AS SPECIFICATIONS FOR IDENTIFICATION1 T C U : 7 OF ALL OWNER SUPPLIED ITEMS, ALL ITEMS NOT MARKED AS 'OWNER SUPPLIED' ARE TO BE SUPPLIED 1" 1 ___.. ..__CI, fo BY GENERAL CONTRACTOR. UNLESS NOTED OTHERWISE, AU. ITEMS ARE TO BE INSTALLED BY GENERAL CONTRACTOR. • 0 a FOR CONSTRUCTION DETAILS NOT INDICATED, USE THE MANUFACTURER'S APPROVED SHOP DRAWINGS/ ry 1 -7'-V'T'1" /C" 1 O ��D AR DATA SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS. lik0 ��5� L4 THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO ANY WORK ri '� AND SHALL BE RESPONSIBLE FOR ALL WORK AND MATERIALS INCLUDING THOSE FURNISHED BY P I ro ru DAM SCOTT WIND1 E 9 SUBCONTRACTORESPONSIBILLITYRS. THE GENERAL FOR THE CONDITION OF THE EXITOR STING SITE ORL ACCEPT PREMISES AS EXISTING STRUOUND.CTURES ATER ASSUMES THE TIME OFND PLUMBING FIXTURE COUNT CODE INFORMATION LIST OF CONTACTS P1.0 PLUMBING FLOOR PLANS • 0 0 ©AN°•.TExAS • BIDDING OR THEREAFTER. .. HEREAFTER. BUILDING CODE: 2014 OREGON STRUCTURAL SPECIALTY CODE P2.0 PLUMBING SCHEDULES • Q d", p� THE GENERAL BUILDING PERMITS SHALL BE PAID FOR BY THE OWNER. ALL OTHER PERMITS SHALL BE TOTAL OCCUPANCY: 47 OWNER ARCHITECTURAL lir'10 SECURED AND PAID FOR BY THE SUBCONTRACTOR DIRECTLY RESPONSIBLE. ALL REQUIRED CITY, COUNTY OSCC, TABLE 2902.1 ELECTRICAL CODE: 2017 OREGON ELECTRICAL SPECIALTY CODE P3.0 PLUMBING DETAILS • 0 �O F MECHANICAL CODE: 2014 OREGON MECHANICAL SPECIALTY CODE ONE MALL GROUP - AMERISLEEP DAVID SCOTT WINDLE, AIA AND /OR STATE LICENSES SHALL BE ACQUIRED AND PAID FOR BY THE INDIVIDUAL SUBCONTRACTOR. TYPE M, 1 PER 500 MECHANICAL: THE GENERAL CONTRACTOR SHALL VERIFY LOCATIONS OF ALL FLOOR DRAINS, ELECTRICAL AND PLUMBING PLUMBING CODE: 2017 OREGON PLUMBING SPECIALTY CODE 7167 E. RANCHO DR. SUITE 137 1431 GREENWAY DR. SUITE 510 fa 01/21/2019 11 STUB OUTS, AND ALL OTHER WORK UNDER THIS SCOPE OF RESPONSIBILITY. CONTRACTOR TO BEAR SYMBOL LEGEND ENERGY CODE: 2014 OREGON ENERGY EFFICIENCY SPECIALTY CODE - SCOTTSDALE, AZ. 85251 IRVING, TEXAS 75038 M1.0 MECHANICAL FLOOR PLAN I COSTS FOR RELOCATION'S OF ALL ROUGH-INS, IF NOT INSTALLED PER APPROVED PLANS. ACCESSIBILITY CODE: 2012 ADAAG STANDARDS PHONE: 316.889.5945 PHONE: 972.870.1288 M2.0 MECHANICAL SCHEDULES • o ISSUE FOR THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR THE COMPLETE SECURITY OF THE SITE WHILE OCCUPANCY: GROUP M EMAIL: ERICOAMERISLEEP,COM EMAIL RSAENZOIDSTUDI04.COM M3.0 MECHANICAL DETAILS • 1/4" ® CONSTRUCTION 12 JOB IS IN PROGRESS AND UNTIL JOB IS COMPLETED. THEFT OF ANY OWNER SUPPLIED ITEMS, FLOOR PLAN CONSTRUCTION TYPE: TYPE Il-B, FULLY SPRINK LERED ELECTRICAL: ACCEPTED BY CONTRACTOR, SHALL BE THE RESPONSIBILITY OF THE GENERAL CONTRACTOR. DRAWING TITLE CONTACT: ERIC SALCEDO CONTACT: ROGER SAENZ/SCOTT WINDLE =1'-0" E1.D LIGHTING FLOOR PLAN 13 ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE LEFT IN A CLEAN (BROOM) SCOPE OF WORK MECHANICAL/PLUMBING/ELECTRICAL STRUCTURAL_ •Y CONDITION AT ALL TIMES DURING CONSTRUCTION. _ E1.1 ELECTRICAL POWER PLAN 0 •• De THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY WATER, POWER, HEATING, TELEPHONE, OFFICE, RETAIL FINISH OUT FOR MALL TENANT WITH NEW EXTERIOR FACADE FACING PARKING BRIAN EDWARD CHANDLER, PE TCS ENGINEERING E1.2 ELECTRICAL SPECIAL SYSTEMS PLAN • 5 14 AND TOILET FACILITIES AS NECESSARY FOR DURATION OF PROJECT. Alk1431 GREENWAY DR. SUITE 510 1999 CALLOWAY LANE Q GENERAL CONTRACTOR IS RESPONSIBLE FOR RECEMNG, UNLOADING AND HOOKUP OF ALL EQUIPMENT SECTION rC)CCUPANCY LOAD CALCULATION IRVING, TEXAS 75038 PRISCO, TEXAS 75034 E1.3 ELECTRICAL SPECIAL SYbIEMS ELEVATIONS • • 15 AND OTHER OWNER FURNISHED ITEMS. A5.0 OCCUPANT LOAD OCCUPANCY - E2.0 ELECTRICAL SCHEDULES w USE SQUARE FOOTAGE • • u THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR AND SHALL REPLACE OR REMEDY ANY FAULTY, SECTION I.D. NUMBER FACTOR AMOUNT PHONE: 972,870.1288 PHONE: 972.849.2987 / EMAIL BCHANDLER@IDSTUDI04.COM EMAIL TRAV®TCSENG.COM [2.1 ELECTRICAL RISER DIAGRAMS AND SCHEDULES 0 • M SHEET WHERE SECTION RETAIL SHOWROOM 1759 60 30 - _ ._ �n 16 IMPROPER OR INFERIOR MATERIALS OR WORKMANSHIP WHICH SHALL APPEAR WITHIN ONE (1) YEAR DR -_ - N w AS OTHERWISE SPECIFIED FOR A SPECIFIC COMPONENT AFTER THE OPENING OF THE RETAIL BUSINESS IS LOCATED VESTIBULE/CORRIDOR 298 60 5 _CONTACT: BRIAN CHANDLER CONTACT: TRAV SWEATMAN a _I Fw- UNDER THIS CONTRACT. Alibi RETAIL NAP ROOM 1 116 60 2 Z 2 wul N GENERAL CONTRACTOR IS REQUIRED TO LABEL ALL ELECTRICAL PANELS, MECHANICAL EQUIPMENT, Al.1! -- RETAIL NAP ROOM 2 116 60 - 2 w Q - 17 PLUMBING VALVES, AND HVAC EQUIPMENT WITH PLASTIC PHENOLIC ENGRAVED PLATE, SECURELYII Q Co ATTACHED. OFFICE 61 100 1 Q DETAIL (ENLARGED) I I - WI a CI 18 ALL ELECTRICAL, MECHANICAL AND PLUMBING WORK SHALL CONFORM TO THE REQUIREMENTS OF l j STORAGE 67 300 1 - W O' © = Q LEGALLY CONSTITUTED AUTHORITIES HAVING JURISDICTION. ----- ELECTRICAL 63 - 300 1 DETAIL I.D. NUMBER Z z L7 Z _ GENERAL CONTRACTOR SHALL SUBMIT WITHIN TWO (2) WEEKS OF PROJECT AWARD ALL SHOP DRAWINGS, TOTAL 42 J r SHEET WHERE SECTION Z �7 HN _I g p UNLESS NOTED OTHERWISE. OWNER AND/ OR ARCHITECT WILL REVIEW ALL SHOP DRAWINGS AND IS LOCATED _ z N LLT N 19 SAMPLES FOR CONFORMANCE WITH DESIGN CONCEPT OF THE PROJECT. THE OWNER AND/ ORIIII ARCHITECT'S APPROVAL OF A SEPARATE SPECIFIC ITEM SHALL NOT INDICATE APPROVAL OF AN ENTIRE ELEVATION SITE LOCATION �,, ,0 o ASSEMBLY IN WHICH THE SPECIFIC ITEM FUNCTIONS. Q u ' trs MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL CONFORM TO THE BUILDING CODE A2.0 ELEVATION I.D. NUMBER n 20 AND LOCAL GOVERNING BUILDING CODES/ ORDINANCES. SHEET WHERE SECTION a z PIPES AND DUCTS EXCEEDING ONE THIRD THE CONCRETE SLAB OR CONCRETE WALL THICKNESS SHALL IS LOCATED -31 21 NOT BE PLACED WITHIN STRUCTURAL CONCRETE UNLESS SPECIFICALLY DETAILED AS SUCH. REFER TO Q w CEILING HEIGHT ABOVE ~ MECHANICAL AND/ OR ELECTRICAL DRAWINGS FOR LOCATION OF SLEEVES, ACCESSORIES, ETC. C _FINISHED FLOOR oss.�. __t, 22 HOT WATER TEMPERATURE AT ALL HAND SINKS TO BE CALIBRATED TO 110 DEGREES FAHRENHEIT. CEILING HEIGHT 10_O t ALL BIDDING IS ADMINISTERED BY OWNER AND/ OR ARCHITECT. ALL REQUESTS FOR CLARIFICATIONS DOOR NUMBER ~' _'`" .4 23 SHALL BE SENT TO OWNER AND OR ARCHITECT. DOOR DESIGNATION " / 0 0 . :,p»...., 9............- TT IS THE INTENT OF THE ARCHITECT THAT THIS WORK BE IN CONFORMANCE WITH ALL REQUIREMENTS " " '" ..,..,.,,,o.p 24 OF THE BUILDING AUTHORITIES HAVING JURISDICTION OVER THIS TYPE OF CONSTRUCTION AND WINDOW NUMBER "� OCCUPANCY. WINDOW a DESIGNATION THE GENERAL CONTRACTOR SHALL SUPPLY, LOCATE AND INSTALL INTO THE WORK: ALL INSERTS, WI o F t , SQUARE MALL `"A.,,� K_� a S 25 ANCHORS, ANGLES, PLATES, OPENINGS, SLEEVES, HANGERS, SLAB DEPRESSIONS AND PITCHES THAT MAY , DESIGNATION BE REQUIRED FOR ATTACHMENT AND ACCOMMODATION OF OTHER WORK. FINISH MATERIAL I P-1 - ° MOST DETAILS AND SECTIONS INDICATED ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL TRIM ONLY -..---COMMENTS, IF APPLICABLE AMERISLEEP ' �� 26 BE CONSTRUED TO APPLY TO SIMILAR SITUATIONS ELSEWHERE IN THE PROJECT EXCEPT SPECIFICALLY """ WHERE A DIFFERENT DETAIL IS INDICATED. O KEYED NOTE DESIGNATION ! l IT IS THE GENERAL CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE ERECTION PROCEDURE AND KEYED NOTES ON APPLICABLE SHEET 27 SEQUENCING. A , APPROVAL FOR DEVIATIONS FROM THESE PLANS SHALL BE OBTAINED IN WRITING FROM OWNER AND DATE DESCRIPTION 110201B V ISSUE FCR FERNF 28 ARCHITECT PRIOR TO EXECUTION OF THE AFFECTED WORK. 29 ALL REQUEST FOR CLARIFICATIONS DURING CONSTRUCTION TO BE SUBMITTED TO OWNER AND COPIED TO REVISIONS ADDENDUM NUMBER f rcl21/20,9 IssuE ECR CONSTRUCION THE ARCHITECT, -4-----REVISED AREA CLOUDED ,t �.� LANDLORD GENERAL NOTES 'il ` itiF GENERAL CONTRACTOR MUST COORDINATE ALL DUMPSTER/TRASH REMOVAL ACTIVITIES WITH ROGER OTT, 1 OPERATIONS MANAGER, CONTACT - ROGEROTT©MACERICH.COM OR 503-639-8865. ELEVATION HEIGHT . . . T.D. S�As�--REFERENCE POINT TRUE 2 THESE PLANS SHOULD BE FORWARDED TO THE AWARDED GENERAL CONTRACTOR TO BE ON-SITE AT ALL 1OO'- "ELEVATION HEIGHT DATE DESCRIPTI9N TIMES. NORTH 2ina13 -PFaesrrRedt�or TENANT'S CONTRACTOR MUST REPAIR ANY/ALL LANDLORD PROPERTY DAMAGED DURING T.T. WORK AND EQUIPMENT EQUIPMENT NUMBER/LETTER 3 COMPLETE LANDLORD'S PUNCHLIST AS DIRECTED BY LANDLORD'S REPRESENTATIVE. CO DESIGNATION KEY PLAN . 4 TENANT'S CONTRACTOR MUST CONTACT WITH MALL'S REQUIRED VENDORS - SEE CRITERIA FOR INFORMATION. - WALL TYPE .-IT...,---WALL TYPE NUMBER - PRIOR TO SAWCUTTING OR PENETRATING THE EXISTING SLAB, VERIFY LOCATION WITH LANDLORD'S 5DON- UTILITY CONDUAITS TENANT'S CONTRACTOR WILL BE RESPONSIBLE FOR ANY DAMAGE TO EXISTING AMERISLEEP NOTES f 6 TENANT GENERAL CONTRACTOR MUST PROTECT MALL TILE FLOOR BETWEEN BARRICADE AND STOREFRONT. NOTE: THE GENERAL CONTRACTOR SHALL HELP ASSIST THE OWNER'S FURNITURE AND LIGHTING ON-SITE ANY DAMAGE OCCURED DURING CONSTRUCTION MUST BE REPLACED AT TENANT'S EXPENSE. CONSULTANTS IN ASSITING THEM TO MOVE, SHIFT, LIFT, AND ASSEMBLE THE FOLLOWING ITEMS: _ . NOTHING IS PERMITTED TO BE ATTACHED TO, SUSPENDED FROM, OR PENETRATE THE ROOF DECK ABOVE. �� ° ' AND/OR SUSPEND AS NEEDED, TO/FROM THE TOP CHORD OF (1} INTERACTIVE TABLE MOVED INTO PLACER: �` ip. �T1T 7 YOU ARE REQUIRED TO FRAME, BRACE, JOISTS OR STRUCTURAL STEEL WHICH EXISTS ABOVE YOUR RESPECTIVE TENANT SPACE. lip '�" (2) GRAPHIC PANELS AND FRAMES FOR INSTALLATION --, ' .4 f �"' • ' • 8 A WATER SHUT OFF VALVE MUST BE INSTALLED AT EYE LEVEL, USING A BALL TYPE VALVE, AND CLEARLY _ _ TITLE SHEET LABELED "WATER SHUT OFF VALVE". PROVIDE FLOOR DRAIN IN TOILET ROOM DICK'S -- `t 1� r (2) FABRIC PANELS AND FRAME INSTALLED - UNDERNEATH THE GRAPHICS PANELS SPORTING " -r {.� 9 SIGNAGE MUST BE SUBMITTED UNDER SEPARATE COVER FOR LANDLORD REVIEW AND APPROVAL. �.r t t LY 1 PLUMBING NOTES (5) LAMP SHADES - FASTENED TO THE WALL TENANT SHALL PROVIDE A MAIN WATER SHUT OFF VALVE LOCATED AT EYE LEVEL IN A WALL BEHIND A (1) MATRESS PLINTH FOR THE ENTRY AREA ,- ; I - --ir LABELED ACCESS DOOR. LOCATE IN OR NEAR EMPLOYEE RESTROOM AS DESIGNATED BY LANDLORD - . , : - J ---' -7^- . , TOILET FACILITIES SHALL BE DESIGNED IN COMPLIANCE WITH ALL APPLICABLE ADA AND BUILDING I .� 't I' ! li .!: A 'i1 I I. (1) DUVET DISPLAY 4i;ia 11' , &'o , 1 DATE REVISION ISSUE - DEPARTMENT CODES. - PROVIDE A 3" FLOOR DRAIN AND CLEANOUT -- EACH RESTROOM MUST HAVE AN "'�. ` T - ' + . EXHAUST SYSTEM - FLOOR FINISHES IN TOILET ROOMS SHALL BE CERAMIC TILE WITH A COVED 6" BASE MAcrs G 09.12.2018 ISSUE FOR LL REVIEW s rNUNsaE,a - TENANT IS REQUIRED TO PROVIDE A WATERPROOF MEMBRANE BENEATH THE FINISH FLOOR SURFACE (5) BED INFO DISPLAYS ""'' 1 t. LC1. , •I I. '• '+:111111 g 09.24.2018 ISSUE FOR PER IT/LL REVIEW UP TO A HEIGHT OF 4" ALONG ALL WALLS - TOILET ROOMS WALLS AND CEILING SHALL BE AMERISLEEP , , � . = �r - CONSTRUCTED OF METAL STUDS WITH WATER RESISTANT 5/8" TYPE X GYPSUM BOARD APPLIED TO THE (2) PILLOW/SHEET CABINETS MOVED INTOPLACE SPACE T11 r. _ .....;W--1-fil - NORDSTROM = 10.16.2018 UPDATED PERMIT/LL SHEETS T1 . 1 INTERIOR SIDE OF THE TOILET ROOM, AT A MINIMUM, INTERIOR WALL FINISHES SHALL BE LIGHT COLORED k- ,-, """" ENAMEL PAINT WITH A 4'-0" HIGH WAINSCOT EXTENDING 24" ON EACH SIDE OF, AND 24' BEYOND THE . • : Oji` 11.05.2018 UPDATED PERMIT/LL SHEETS FRONT PORTION OF ANY WATER CLOSET DR URINAL. THE CEILING SHALL BE A MINIMUM OF 8'-0' ABOVE r --- -� 01.21.2019 ISSUE FOR CONSTRUCTION , THE FINISHED FLOOR LEVEL, BE CONSTRUCTED OF 5/8' TYPE "X' WATER RESISTANT GYPSUM AND BE =:- .... FINISHED WITH ENAMEL PAINT. THE CEILING SHALL CONTAIN A VENT, WHICH SHALL BE CONNECTED TO1111 - - ' PRO-ECT NI It ER: THE LANDLORD'S EXHAUST SYSTEM OR AS PURSUANT TO THE CENTER REQUIREMENTS. 1III - -- TRUE NORTH AMS18001 GENERAL NOTES ENGINEER: A. ALL OUTDOOR AIR INTAKES BY MECHANICAL EQUIPMENT SHALL HAVE A MINIMUM 10'--0" HORIZONTAL CLEARANCE FROM THE DISCHARGE OF ANY BRIAN EDWARD EXHAUST FAN, COMBUSTION EXHAUST OR PLUMBING VENT. CHANDLERPE , 8. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING CONNECTIONS TO ALL MOVING MACHINERY NOT INTERNALLY ISOLATED. 1431 GREENWAY DRIVE C. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. SI TX 75038 D. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER PHONE 972.870.1288 LOCATIONS WITH LIGHT FIXTURES AS WELL AS SPRINKLER PIPING AND HEADS E-MAIL:bchandler@idstudio4.com (WHERE INCLUDED IN THE PROJECT) FOR A COMPLETE INSTALLATION. E. LOCATIONS FOR THERMOSTATS AND REMOTE SENSORS SHALL BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL-MOUNTED DECOR OR PROXIMITY TO HEAT PRODUCING EQUIPMENT. F. ALL MAC AND RESTROOM EXHAUST DUCTWORK SHALL BE INSTALLED AS HIGH AS POSSIBLE UNDER THE ROOF STRUCTURE. G. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA cORPCRATE• STANDARDS. ALL JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED BY APPROVED METHODS. ONE MALL GROUP-AMERISLEEP H. ANY FLEXIBLE DUCTS SHALL BE INSTALLED IN CONCEALED SPACES ONLY. 7167 E.RANCHO DR.,SUITE 137 THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-O". SCOfISDALE,AZ.85251 ALL FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND 486.446.3034 FITTINGS WITH A PANDUIT-TYPE BAND, AND SHALL NOT BE ATTACHED WWW.AMERISLEEP.COM DIRECTLY TO THE AIR DEVICE COLLAR. I. SUPPLY, RETURN, RESTROOM EXHAUST DUCT CONSTRUCTION SHALL BE GALVANIZED STEEL. GAUGES, SWAY BRACING AND SUSPENSION SHALL CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND �p PROF WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD �� Ess IS NOT ALLOWED (UNO). ��GtN�F9 >oy J. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING 80301'E THE AIR FILTERS AT THE AIR HANDLERS AND ROOFTOP UNITS WITH • , PLEATED MERV 8 THROW AWAY TYPE AIR FILTERS AT THE COMPLETION WITH . • '•/'V OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. co s OREGON ck.„ K. AT THE START OF CONSTRUCTION, THE MECHANICAL CONTRACTOR SHALL X94, 24.Al x' , FIELD VERIFY THE VERTICAL CLEARANCE REQUIRED FOR INSTALLATION OF FOI4 f RD Q,\',P EQUIPMENT AND DUCTWORK IN COORDINATION WITH EXISTING CONDITIONS, INCLUDING ROOF STRUCTURE, AND PROVIDE DIRECTION TO THE GENERAL EXPIRATION DATE: 12-31-2019 CONTRACTOR FOR FINISHED CEILING HEIGHTS AND ROOF OPENINGS. ANY 01/21/2019 REQUIRED DEVIATION FROM THE HEIGHTS SHOWN IN THE ARCHITECTURAL ISSUE �0 R CEILING PLAN SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT AND TENANT'S CONSTRUCTION MANAGER. CONSTRUCTION RR Q• PPisD W 1006"0 C-15) i ® KEYED NOTES W 300 A 1 (TYP 2) I (TYP 6) 1. EXISTING AMU AND MAIN DUCTWORK TO REMAIN AS SHOWN. FIELD ADJUST Q r ill i 1 ` —- \ - 7_ \\ � \ \ \\ \ � � \\\ \ \\ l \"\ \\� 1\ � \ . \ LOCATION TO AVOID ANY CONFLICTS WITH ARCHITECTURAL CHANGES. AIR �'""� Lu 11 �- _ � �� \�`� � � - BALANCE INFORMATION REFERENCED ON SHEET M2.D. •w� w . ! \ 'Il G.!Ti II _ — — --- 2 EXISTING RETURN AIR SMOKE DETECTOR TO REMAIN. FIELD VERIFY d Q Q- N. CD2 f - 1):17)\ X I r-Q� r e LOCATION AND OPERATION. w `� 03. EXISTING DUCT HEATER TO REMAIN. CONTRACTOR TO VERIFY UNIT IS IN N v w 6"4 50 \ O / / \ 2 WORKING CONDITION AND REPLACE IF NEEDED. Z aO a = r- 4. EXISTING MOTORIZED DAMPERS INTERLOCKED TO UNIT SUPPLY FAN TO W1/1 III CDT CR _. REMAIN. VERIFY LOCATION IN FIELD. BALANCE OUTDOOR AIR TO 650 CFM. 0 Q •in 6"4 50 965 .I r-- -1 5. RELOCATE EXISTING TEMPERATURE CONTROLS FOR UNIT AS SHOWN. W a °O TYP 2) \ ._- Ni { L - J kgiw COORDINATE INSTALLATION WITH WALL DECOR/EQUIPMENT. O' =O = Q gi , ' '- - '\ \ \\ ° ° i i i 6. FIELD VERIFY THAT EXISTING DUCTWORK TO REMAIN IS INSULATED. IF z Z •�j _T NOT, PROVIDE EXTERNAL INSULATION FOR EXISTING DUCTWORK PER O , �' SD }� (TYP) \ J -----.. _...1 J 'LOCAL CODE REQUIREMENTS. I� L Z N J 0 ■ �1 8"0 / �� i .� `.\ r��� _ " 7. SLOT MOUNTED RETURN AIR TRANSFER DEVICE. ti W 150 ` i �..• L - I - �/ = v� rn n F- flii41 1 (TYP 2I L - 1 _ «-moi - 8 PROVIDE CEILING MOUNTED TOILET EXHAUST FAN. ROUTE THE 8" O Z ° O l i I I EXHAUST DUCT TO THE EXISTING LANDLORD COMMON EXHAUST DUCT, W O n vVi 1` I , ; VERIFY LOCATION OF LL EXHAUST DUCT IN FIELD. j' , 111141 It*� re =� 9. REMOVE TRANSFER FAN AND ASSOCIATED DUCTWORK. M Q 6 LK4.W11M1M16. ..\MIILVIllek.,'W. ®- . O II® O O a C O 0 O �� W. CAP EXISTING DUCTWORK AS SHOWN AND RE BALANCE ZONE PER Q o U N ► J (TYP) • 80 , DRAWINGS. -_. 00 © • is O 0 0 O 0 0 0 I. 11. RETURN GRILLE AIR QUANTITY LISTED IS FOR PARTIAL RETURN DURING OO • -- `� (TYP 4) \ STANDARD OPERATING HOURS. RETURN DUCTS ARE SIZED FOR FULL 24"0(EX) r ■ 1 24'o(EX) A �� - D Q a O O RETURN DURING NIGHT SETBACK CONDITIONS. REFER TO SHEET M2.0 FOR r 1: � 20X20(EX)■ �e��s�����r���-- s 1/ „® W THE AIR BALANCE REPORT ON DESIGN AIRFLOW RATES. 4 i. �� I j O _� AHU-1(Ex) :11 �� "'�� �_ (TYP) �AI_�_ 00 I 1 �� 12. DCOCNNE�pRKNEW DUCTWORK SIZED AS SHOWN TO EXISTING MAIN ® +'r 1 22X18(EX) I I 14X18(EX) I - •k: • • Wei' : " � ;]` C. {} _-- -- �.� • - -- — ---.- - J I 14. EXISTING RELIEF DUCTWORK TO REMAIN. VERIFY AND/OR FIELD ADJUST ', .� �� i :TY: , i I __.__ i LOCATION TO AVOID ANY CONFLICTS WITH ARCHITECTURAL CHANGES. AIR• 4 �� a ®11 0 ' 1 1 BALANCE INFORMATION REFERENCED ON SHEET M2.0. k f } • ��•�� 8x10 / 5 AHU-t T i® 15. EXISTING OUTDOOR AIR DUCTWORK TO REMAIN. VERIFY AND/OR FIELD i � •, i ♦ OO I ADJUST LOCATION TO AVOID ANY CONFLICTS WITH ARCHITECTURAL id; �aGI ����- CHANGES. AIR BALANCE INFORMATION REFERENCED ON SHEET M2.O. ?Q • e • Sr.=N.- li "�I "A. -'1r �4. 'a•'Al :'v :\i. :`1.- •A. "4`4%. t. '!► ?tr' 'V• . � / O i ,� 0 0 Ocill, I O O O I O O #1 17. MECHANICAL CONTRACTOR SHALL VERIFY CONDITION OF EXISTING AIR DATE DESCRIPTION `'r '• � w 12x10 J i / DEVICES LOCATED IN RECESSED EXTERIOR AREA AND BRING TO vowel ISSUE FOR PERM" I MP) I C1) II 'LIKE-NEW' CONDITION. ,/2U2C120X20 a 011reg __ - \\. `��`.�� �` »�..�_ �,,. - . W _. . \ \\N\ -\ \ \ \ \, , \ z ' \ ,- -Ii. .\,\`.\ 1W ... = \ \\\ ® CD1 CR SD ifS. DATE DESCRIPTIM h . v 1O"4 350 UP` C 305 I2 250 6"0 I I1 01.21.19 FERN7TREYISIDN • sHEET TTELE.. MECHANICAL FLOOR PLAN SHtEcT NUMBER: M1 . 0 PROJECT NUldBER. MECHANICAL FLOOR PLAN 1 AMS18001 0' 1/4"=1'- ENGINEER: EXISTING FAN COIL UNIT SCHEDULE MECHANICAL LEGEND GENERAL NOTES BRIAN EDWARD AIR OA EXT FLUID FLUID COOLING PERFORMANCE (EXIHEATING PERFORMANCE ELECTRICAL WEIGHT REMARKS SYMBOL ABBR. DESCRIPTION 1. FOR THE PURPOSE OF CLEARNESS AND LEGIBILITY, THE DRAWINGS ARE CHANDLER, PE MARK MANUFACTURER MODEL FLOW FLOW S.P. FLOW PD EAT LAT EWT LWT TOTAL SENSIBLE HEAT CAP VOLTS/PHASE/HZ MOTOR FLA MCA MOCP (LBS) ESSENTIALLY DIAGRAMMATIC AND ALTHOUGH SIZES AND LOCATIONS OF 1431 GREENWAY DRIVE (CFM) (CFM) (IN W.C.) (GPM) (FT) ('IDB/WB) ('IDB/WB) (F) CO (BTU/HR) (BTU/FIR) (KW) HP (AMPS) (AMPS) (AMPS) EQUIPMENT ARE DRAWN TO SCALE WHEREVER POSSIBLE, THE CONTRACTOR El CD CEILING DIFFUSER - SUPPLY SUITE 510 (EX)AHU-1 TRANE MCCB006 3000 650 - VERIFY VERIFY VERIFY VERIFY - - VERIFY VERIFY 7.5 460/3/60 - VERIFY VERIFY 20.0 - 1 SHALL MAKE USE OF ALL DATA THROUGHOUT THE CONTRACT DOCUMENTS AND IRVING,TX 75038 • - - VERIFY THIS INFORMATION PRIOR TO ORDERING, FABRICATING OR INSTALLING PHONE 972.870.1288 1 1)(1 CD CEILING DIFFUSER BELOW DUCT - SUPPLY ANY MATERIALS. E-MAIL: bchandler@idstudio4.corn - . . _ 2. THE MECHANICAL CONTRACTOR SHALL PROVIDE COMPLETE INFORMATION AND COOPERATE WITH THE OTHER CONTRACTORS AND TRADES AS REQUIRED FOR ® SAD RISER - SUPPLY AIR DUCT THE COMPLETION AND COORDINATION OF THE COMPLETE PROJECT. NOTES: 1.EXISTING AHU TO REMAIN. CONTRACTOR SHALL PERFORM MAINTENANCE AND VERIFY WORKING CONDITION TO BRING TO 'LIKE NEW CONDITION. 3. THEL MECHANICAL ON EQUIPMENTUCTOR SHALL BE RESPONSIBLE FOR ADMINISTERING IC NI SAD DROP - SUPPLY AIR DUCT ALL WARRANTIES WHICH THEY FURNISH AND INSTALL PROVIDE IL NI WRITTEN WARRANTY TO REPLACE ALL FAULTY MATERIALS AND/OR LABOR, AT NO COST TO TENANT, FOR A PERIOD OF ONE YEAR FROM DATE OF L CR CEILING REGISTER - RETURN ACCEPTANCE BY THE OWNER. WARRANTIES SHALL BEGIN ON THE DATE OF SUBSTANTIAL COMPLETION. 4. THE MECHANICAL CONTRACTOR SHALL COORDINATE WITH THE GENERAL coRPORaTE •0/A VENTILATION SCHEDULE AIR DEVICE SCHEDULE V: CR CEILING REGISTER BELOW DUCT - RETURN CNTRATORPENETRATIONS ALL REQUIRED OPENINGSEID OTHER TES ALL NIFOREp DAOPeNINGS AND ONS, FLOORS, WALLS ONE MALL GROUP -AMERISLEEP RAD RISER - RETURN AIR DUCT AND ROOF SHALL BE CONSTRUCTED INTO THE STRUCTURE WITH THE USE OF 7167 E.RANCHO DR.,SUITE 137 Outdoor Load Rate Outdoor Occupant Breathing Zone MARK PICTURE FACE SIZE TYPE MOUNTING TYPE MAXIMUM N.C. DIRECTION MANUFACTURER MODEL NOTES SLEEVES, CURBS, ETC. CUTTING AND PATCHING SHALL BE HELD TO A SCOTTSDALE,AZ.85251 Air Rate Area Per OMSC Occupancy Air Rate Outdoor Outdoor Air MINIMUM. 486.446.3034 Area Served Description Area Ft2 Per Outdoor Table C" FI1040 Per Table A€r Vbz= RpPz+ �� RAD DROP - RETURN AIR DUCT 5. THE MECHANICAL CONTRACTOR SHALL COORDINATE ALL DUCT AND DIFFUSER W1''W.AVERISLEEP.COM OMSC LOCATIONS WITH SPRINKLER PIPING, SPRINKLER HEADS AND LIGHT FIXTURES AZ Table RaAz 403.3 PZ 403.3 RpPz RaAz AS REQUIRED FOR A COMPLETE INSTALLATION. CD1 24X24 SUPPLY SURFACE 30 4-WAY TITUS TMS 1,3,5 6. PROVIDE VIBRATION ISOLATION DEVICES AND FLEXIBLE DUCT/ PIPING 403.3 (People) Rp CE CEILING REGISTER - EXHAUST RA 1000(t2) _ ----- CONNECTIONS TO ALL MOVING MACHINERY NOT INIERNALLY ISOLATED. �Ep PROS,- SALES ROSE SALES FLOOR 2240 0.12 269 15 34 7.5 252 521 1i(1 CE CEILING REGISTER BELOW DUCT - EXHAUST 7. MECHANICAL CONTRACTOR SHALL FURNISH AND INSTALL 4" HIGH BLACK OVER ,'-''s\C,iNEs`5/ OFFICE 80 0.06 5 1 5 5 25 30 cI �,� F,I °2 NAP ROOM 300 0.12 36 15 5 7.5 34 70WHITE LAMINATE NAMEPLATE WITH 2" LETTERS VISIBLE ADJACENT TO w v CD2 12X12 SUPPLY SURFACE 30 4-WAY TITUS TMS 1,3,5 -7 DISCONNECT SWITCH FOR HVAC UNITS AND FANS. ,r 8030i•E r� RESTROOM 80 0 0 0 0 0 0 0 [Li F�1D RISER - EXHAUST AIR DUCT 8. ANY FLEXIBLE DUCTS SHALL BE INSTALLED IN CONCEALED SPACES ONLY. ' 8 1 i 1/ STORAGE 85 0.12 10 0 0 0 0 10 I _ •' - _ THE MAXIMUM ALLOWABLE LENGTH OF FLEXIBLE DUCT SHALL BE 5'-0'. ALL 61 OREGON --- -- N - - 't (L) LINED DUCTWORK FLEXIBLE DUCTS SHALL BE CONNECTED TO BRANCH RUNS AND FTTINGS WITH �i 'S'' NS ��¢ TOTAL 0/A 631 CFM A PADUIT-TYPE BAND, AND SHALL NOT BE ATTACHED DIRECTLY TO THE AIR "9"iFOWAR CO, CO REQUIRED SD L. % 48x2--SLOT SUPPLY SURFACE 3D 1-WAY TITUS ML-39 1,2,4,5,7 VD MANUAL VOLUME DAMPER DEVICE COLLAR. `'E 9. SUPPLY, RETURN, RESTROOM EXHAUST DUCT CONSTRUCTION SHALL BE EXPIRAIONDATE: 12-31-2019 NOTES GALVANIZED STEEL (UNO.) GAUGES, SWAY BRACING AND SUSPENSION SHALL 1. CALCULATIONS ARE BASED ON 2014 OMSC, TABLE 403.3 Ol/x112019 FC FLEXIBLE CONNECTION CONFORM TO SMACNA STANDARDS. SEAL ALL SEAMS AND JOINTS AIR AND ISSUE ��e U,t^ FOR 2. OUTDOOR AIR DEMAND IS: - 631 CFM WATERTIGHT. FLEXIBLE ALUMINUM DUCTWORK OR FIBERGLASS DUCTBOARD IS OUTDOOR AIR PROVIDED 15: 650 CFM CRlii, 24x24 RETURN SURFACE 30 1-WAY TITUS PAR 1,2,6,7 NOT ALLOWED. f } NEW DUCT 10. ALL HVAC SUPPLY AND RETURN EXPOSED RIGID DUCTWORK SHALL BE CONSTRUCTION OUTDOOR AIR DIFFERENCE IS: + 19 CFM _ _ . - INTERNALLY UNED AND PINNED WITH MINIMUM R-8, 1-1/2' INSULATION WITH Ank AIR DEVICE DESIGNATION VAPOR BARRIER PER THE 2014 OREGON MECHANICAL SPECIALTY CODE WITH LOCAL AMENDMENTS. INSULATION SHALL HAVE MAX/MUM RATINGS OF 25 FLAME LU ST ....... ,,:\,.. 48x2-SLOT TRANSFER SURFACE 30 1-WAY TITUS MLR-39 1,2,4,6 SPREAD, 50 SMOKE DEVELOPED. REFER TO ARCHITECTURAL DRAWINGS FORCe A � ., 0 TSTAT PROGRAMMABLE THERMOSTAT DUCT PAINT OR COLOR SPECIFICATION TEST AND BALANCE NOTES 11. ALL HVAC SUPPLY AND RETURN CONCEALED RIGID DUCTWORK TO BE Q T Q SEMS REMOTE TEMPERATURE SENSOR EXTERNALLY WRAPPED AND SECURED WITH MINIMUM R-8, 2" INSULATION WITH VAPOR BARRIER PER THE 2014 OREGON MECHANICAL SPECIALTY CODE WITH u� 1. THE GENERAL CONTRACTOR SHALL SUBCONTRACT TO AN INDEPENDENT AIR TEST AND BALANCE - LOCAL AMENDMENTS. INSULAION SHALL HAVE MAXIMUM RATINGS OF 25 FLAME CONTRACTOR FOR THE TESTING, ADJUSTING AND BALANCING OF ALL ENVIRONMENTAL SYSTEMS SHOWN / SPREAD 50 SMOKE DEVELOPED. a M OR SPECIFIED ON THE CONTRACT DOCUMENTS. THIS SHALL INCLUDE EQUIPMENT OPERATION IN JS SD SMOKE DETECTOR c W 12. ALL PENETRATIONS IN FIRE RATED WALL ASSEMBUES SHALL BE SEALED WITH u.i COOLING, HEATING, AND DEHUMIDIFCATION OPERATIONAL MODES. THE WORK SHALL BE PERFORMED BY ❑ v► i_ A FIRM CERTIFIED BY EITHER AABC OR NEBB, AND FOUR (4) COPIES OF THE FINAL REPORT, UL LISTED FIRE STOPPING MATERIAL Q POC POINT OF CONNECTION Z 2 SUBMITTED ON CERTIFYING AGENCY FORMS, SHALL BE SUBMITTED TO THE AMERISLEEP CONSTRUCTION ® 13. ALL DUCT DIMENSIONS SHOWN ON DRAWINGS ARE CLEAR INSIDE DIMENSIONS. w N ,n MANAGER FOR APPROVAL. THE REPORT SHALL BEAR THE CERTIFICATION SEAL OF THE TAB 14. ALL RECTANGULAR, ROUND, AND FLEXIBLE DUCTWORK SHALL BE SIZED AS M O a 1 " SUPERVISOR IN CHARGE. REPORTS SHALL CONTAIN ALL AIR SIDE BALANCING DATA, INSTRUMENTS CFM CUBIC FEET PER MINUTE SHOWN ON THESE DRAWINGS; AND SHALL BE FABRICATED AND INSTALLED W a ' ❑ co USED AND THEIR LATEST CAUBRAION DATES, PERSON(S) PERFORMING THE WORK AND A WRITTEN ACCORDING TO THE MOST RECENTLY PUBLISHED SMACNA STANDARDS. ALL d p GUARANTEE THAT ALL TAB WORK WAS PERFORMED IN ACCORDANCE WITH THE CERTIFYING AGENCY JOINTS, SEAMS, AND CONNECTIONS MUST BE SECURELY FASTENED & SEALED WV vs 0 = STANDARDS AND PROCEDURES. S/A SUPPLY AIR BY APPROVED METHODS. z ce z, .- 2. THE TEST AND BALANCE REPORT SHALL INCLUDE OPERATIONAL DATA FOR EVERY COMPONENT OF THEImmi 15. THERMOSTAT(S) SHALL BE LOCATED AT 48 A.F.F. EXACT LOCATIONS SHALL z COMPLETE MECHANICAL SYSTEM INCLUDING HVAC EQUIPMENT, HVAC AIR DEVICES, KITCHEN FANS, J G RESTROOM FANS, ETC. THIS DATA SHALL INCLUDE THE BALANCED OPERATING DATA FOR EQUIPMENT R/A RETURN AIR BE FIELD COORDINATED TO AVOID INTERFERENCE WITH WALL-MOUNTED WORK z N OR PROXIMITY TO HEAT PRODUCING EQUIPMENT. 2 � tit AS COMPARED TO THE DESIGN AIR BALANCE SCHEDULE ON THIS SHEET. °, W O 3. FOR CLARIFICATION, THE ENGINEER OF RECORD WILL NOT BE ABLE TO REVIEW THE INSTALLED NOTES: (NOT ALL MAY APPLY) 16. A FULL CERTIFIED MECHANICAL AIR TEST AND BALANCE REPORT SHALL BE a f z U MECHANICAL SYSTEMS FOR POTENTIAL OPERATIONAL ISSUES OR INSTALLATION DEFICIENCIES WITHOUT 0/A OUTSIDE AIR L p p N. N 1. PROVIDE NECESSARY MOUNTING HARDWARE AND ACCESSORIES AS REQUIRED FOR INTENDED INSTALLATION. / PERFORMED BY A CONTRACTOR APPROVED BY CLIENT AT THE CC'S EXPENSE, W THE FULL AND COMPLETE TEST AND BALANCE REPORT. 2. AIR DEVICE(S) SHALL HAVE MANUFACTURER APPLIED PRIMER FINISH SUITABLE FOR FINAL PAINT FINISH (BY OTHERS). REFER TO THE PROVIDE TWO COPIES TO THE LANDLORD. 44 LIQ l' ARCHITECTURAL DRAWINGS FOR COORDINATION. EXHAUST AIR Z ON• 17. PER THE 2014 OREGON MECHANICAL SPECIALTY CODE WITH CITY AMENDMENTS Z Q 3. AIR DEVICE(S) SHALL BE FACTORY FINISHED WHITE. WHEN REQUIRED, EACH SINGLE SYSTEM PROVIDING HEATING OR COOLING AIR ,�, a 4. PROVIDE WITH BORDER '22' MOUNTING. (MUD-IN TYPE) IN EXCESS OF 2000 CUBIC FEET PER MINUTE SHALL BE EQUIPPED WITH AN o% I- 5. AIR DEVICE(S) SHALL BE INSTALLED WITH MANUFACTURER AVAILABLE MOLDED INSULATION BACKING. FIELD FABRICATED INSULATION BACKING S.P. STATIC PRESSURE AUTOMATIC SHUTOFF. AUTOMATIC SHUTOFF SHALL BE ACCOMPLISHED BY IS NOT ALLOWED (UNLESS FIRST APPROVED BY THE OWNER'S CONSTRUCTION MANAGER). INTERRUPTING THE POWER SOURCE OF THE AIR MOVING EQUIPMENT DEVICES 6. PROVIDE WITH MANUFACTURER AVAILABLE PLENUM. WHICH WILL DETECT PRODUCTS OF COMBUSTION OTHER THAN HEAT, AND 7. PROVIDE FIELD FABRICATED INSULATION ON ATTACHED PLENUM. FOH FRONT OF HOUSE WHICH COMPLY WITH THE BUILDING CODE, SHALL BE LABELED BY AN APPROVED AGENCY FOR AIR DUCT INSTALLATION AND SHALL BE INSTALLED IN . ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SMOKE DETECTORS BOH BACK OF HOUSE TO BE INSTALLED SHALL BE SEPERATE FROM AND NOT CONNECTED TO THE LANDLORD'S FIRE SPRINKLER AND ALARM SYSTEM. VIF VERIFY IN FIELD 18. THE MECHANICAL CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING THE FAN SCHEDULE AIR FILTERS AT THE AIR HANDLING UNITS WITH PLEATED MERV 8 THROW AWAY TYPE AIR FILTERS AT THE COMPLETION OF CONSTRUCTION AND PRIOR TO AIR BALANCE AND STORE TURNOVER. MARK SERVICE CFM E.S.P. "WG RPM M HP R VOLTS/ PH MANUFACTURER MODEL TYPE WEIGHT NOTES 19. MECHANICAL CONTRACTOR SHALL BE ON SITE AND PRESENT AT THE DATE OF STORE TURNOVER. TEE-1 RESTROOM 100 0.25 390 56.2W 115/1 COOK GC-142 CEILING CABINET FAN 15 1,3,4 NOTES: (NOT ALL MAY APPLY) DESCRIPTION 111;;,,2016 ISSUE FOR PERMIT 1. ELECTRICAL CONTRACTOR SHALL INTERLOCK WITH RESPECTIVE RESTROOM LIGHT SWITCH FOR SIMULTANEOUS OPERATION. 31/21,20 IEISSUE FOR CDNsrRuC11D N 2. FAN SHALL BE CONTROLLED BY WALL MOUNTED SWITCH. -. 3. FACTORY AVAILABLE GRAVITY BACKDRAFT DAMPER. 4. FURNISHED AND INSTALLED BY MECHANICAL CONTRACTOR. QDATE DESCRIPTION I tI1,21.19 PERMIT REVISION , SHEET TTL MECHANICAL SCHEDULES SHEET NUMBER: X12 . 0 PROJECT NUMBER. AMS 18001