Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
F PS20 19 -00016 SCOPE OF WORK SPRINKLER SYMBOLS SYMBOL STATUS BRAND SIN TYPE FINISH TEMP (F) ORIFICE THREAD 'K' FACTOR NOTES TOT. 1) The area of work shown is to have fire sprinkler drops installed in a 0 NEW TYCO TY3531 SSP-QR wh 155 1/2" 1/2- 5.6 25 new ceiling and at new walls (ceiling and walls by others) changes to JCPenney the sprinkler system designed, fabricated and installed in accordance +a�.� ,,,,� . . 0 NEW TYCO TY323 SSP-OR Hm/NM 155 1/2' i/2' 5.6 3 with NFPA 13 2013 and local standards. .�� = RECEIVED 2) The area of work is a mercantile space. `? ' :11,_.,"ii 3) This contract is limited to area of work shown. _ :f FEB 1 2 ��I�y CITY OF TIGARD DICK'S — � t. SPORTING � '' GENERAL NOTES G°°°5 � - - BUILDING DIVISION 1) Area of work is to be protected as an Ordinary Hazard occupancy _____r- "' . "} r r - i, per NFPA 13 2013. • • - I a ; , ;616' •. .—a 1 I —I 1 - 7 2) All materials devices and hangers used on this project shall be UL : ,. � 1 Listed and/or FM Approved for use in fire protection systems. r r{ 14 `, r1 1:r r; , ft .1t 1+ N ' I L: - ., .,,J ,,_ice I .r-- , F. 3) See attached 'Equipment Data Submittal' for all applicable materials ._ - and equipment used in this project. MACV'S -- o:1 ' r l 242 SOS SF 1 53 I f t. 1• • 1, I 1... .;:,: .; .q.! ` , 1 :'ti 4 4) All new piping to be 1"black steel, Eddythread40 (or equivalent) AMERISLEEP ' I with threaded ductile iron fittings cut in from existing heads. F4: .. r: . SPACE Ti 1 r F ' I .- u .: hi •—f NORDSTROM 5) Maximum spacing per head is as listed in Sprinkler Symbol table. " `" ' ' __ 6) Any and all painting or paint preparation of piping to be by others. , ,_ I r : 7) Pipe hangers including on all armovers 2'-0' or longer to be ..... . . . . = ` installed in accordance with NFPA 13 2013 and per local AHJ. 1.1 r. -- TRUE 8) Sprinklers to be installed in accordance with NFPA 13 2013 and per the local AHJ. NORTH 8) All elevations measured from finished floor of existing building. 10) If field conditions result in a change to the shop drawing KEY PLAN installation In any way, contact the project engineer to verify proposed changes are compliant with NFPA 13 requirements. NOT TO SCALE 11) This print or drawing shall be used only with reference to contracts of proposals of Wyatt Fire Protection, Inc. This print or drawing shall not be copied for, reproduced for nor exhibited to outside parties. This print or drawing and any and ail copies therefore shall be returned to Wyatt Fire Protection, Inc. upon request. Nothing disclosed herein not publicly available shall be used without written permission from Wyatt Fire Protection, Inc. -en.•.o "' -p` s.a;-.u..j ides 1 }r 9 4 S SF 4 3 - j a.rl.CL"r"r, 1,11Veic.V.pcdt9 .11•.%41 42 F7 Lam-ode Y A.V 9„„,.". i .Z . dr 40 k....� hr � �`'` k , .# WASHINGTON �1 �,.., HANGER KEY SQUARE MALL 1 " a� h �p i , ' .. YfOFFICE COPY 1 TrImllne Adjustable Band Hangar .I',• Ge1°'r"""'9 ~' n y+ 1 2 %" Threaded Rod AMERISLEEP ----... b it F 3 Sammles far Steel _ -- 1 1 O 4 Metal Structure _- , fp;)44 rPAr{1V�.Irl1 'p�� 1i REVIEWED BY: _-- _ 9 = -.-.4.,==.7.9n Q Digitally signed by • gilts m...� 'Wall r Ashley Ashie Nishihara . o%PM — �t . — - _ r Date•2019 2 7 Nishhara gT 12:13:05-08'00' Y� .Q �I>�3'�•1 .' �.;.f�. II,I'i •I• Q(.]Iragp/Tlt'aCa t -,.......;=',...:'' t t` i Rt~0 PROF fa 0 Wpm xnr. W r s ' :yrs.,t-¢ Ss a t r..r lit �� 1 N / Itzi 7 83 2 E, . { TRUE • ' ' / OR GON HANGER DETAIL VICINITY MAP p�ti6... 11,2Q�s�\�P�� AYNE NN NOT TO SCALE NOT TO SCALE EXPIRES: DEC 31, 2020 RR Q• pp POWER DRIVEN SHOTIN• REVISIONPERMIT S 2/7/2019 ANCHORS USED FOR SEISMIC APPLICATION SHALE.REQUIRE SPECIAL 1 INSPECTION' OR.INTER P 10-01 Q — — — _ �\S _ \7\ \\\ \ \\`\'\\7\\ \C\-\\-\\ -� \\ \\- \\ \ \7\`- ' �\� _ jw COPEI] 0i \.�3'-1 1/2"/- 1 - �- -- —� — — — IMO t PROVIDE EITHER FLEXIBLE SPRINKLER / \ 4'-3 1/2" 3'-7" ' / Q\ — ;� © 3 7 r HEAD OR 2-INCH I 3'-9,♦ / t ,rl f .7.--re / 4' 3 1/2" / I I I OVERSIZE RINGS . O N x \ RESTROOM ii1 N 9r w (i) DR. INTERP 10-01 iS EA \ 9 4'-9. 1 V-4" 12-8 12'-8' I \ L�- o � ooM 0 NAP cROOM� ° / l 10 \ qp-0" - • l N. 1 \ \ l\\ \ 1 \ \ \ \ \:\ I P. 1 3' 1103 1 VL O T r r r n 3'-3 1/2" 4'-0' 1 3'-9" 10'-0" 10'-0" 36 -62 -6 [ I 0 0 I I OFFICE COPY' I I u\ \ THIS AREAOSORAGE I \-_[+. - ,i o \ - I- 1 \ 1107 ~ CITY OF TIGARD i -- - I I ii �« r REVIEWED FOR CODE COMPLIANCE NO. DATE DESCRIPTION T \E.i COPEND R CV •'� 1,'-5" I \ 1 P-4 I RETAIL ©TYP. Approved: I \ \ ,� _.= OTC: C‘�cCI L1\y lCI CO P-3 . o I \ I \ .) O 0 © o411) O ® 0 © © O O 101 • O O .\ O I rcrmit#: � ��� l� - E��c7 1 6 1 \_`XL\ \_\____\.__N_\_\___\._.\_ \ \ \ \ �i 1z —o" WYATT Q .sem. r� -t . Address: ��39 Sy.l tnl�sti�S1'o� .� 1t le` ` `;` PROTECTION, INC. 4iD — • - 6'—s" °° 6'-6" 6'-6" o r,'0 1/2" 0 4 0 0 0 0 0 �� O 0 O 0 0 O —O �:4 -�� O Suite#: �� FIRE PR s.w. Burnham <, -5N - By: Date: Tigard.OR 97223 ' 0 t 12' 12' / 11' 3" 12' 92' t g'_3' ,� A O o O O O O O O O ---�-0 ' �� 14')9- (503J 68Q-2928 a\I. o O O / \ O - I I 9095 SW BURNHAM ST • s' 1r s'-a" 6'-6" 6'-6" 6'-6" 6'-6" 6'--6" 6'-6" 6'-6" C-6" 6'-6" C-6" 2'-6" TIGARD, OREGON 97223 ` '� ♦ ♦ ♦ ♦ f ♦ ♦ ♦ ♦ 1 (503)684-2928 ►� I (� : —o TYP. 1� o CORRIDOR 0 ta © I 6 -6" 2 1 12' "' i PLEASE PROVIDE l� -I • 'Lc) 104 / -3" / O r _ N. l MATERIAL AND TEST . �.__ PROJECT: 74 P— © 0 1 ry.-n. 0 /- 11'-5" �P— I \ / / I 68'-6" I 2'-6"1.1 I FINAL INSPECTION AMERISLEEP WASHINGTON I ; , �? O p O O o o O I AL INSPECTION SQUARE 0 I V •. .• 9585 SW WASHINGTON SQUARE RD I o . 4'-O" �n �, 4'-Q" 3'-5 1 2" 3' 3'—.► W 4 SPACE T11 4 © I 0 OFFICE 1 ELECTRIC L 4 • `� O • O 0 1 • T °� �° TIGARD, OREGON 97223 . .1,--1'-]0" -10� �-' r " e � ® I 106:r g� II ti os 10'—�� �0'-7� 10'-7" I 1 a'-7" 1 a'-7" - i1-a � r I OPEN 1 � I 1 I �r la i DAVILA GENERAL CONTRACTORS, LLC; 2100 KRAMER LN, NO U(�� (0'-'"I _ STE 900; AUSTIN, TX 78758 K IN I P--41 NO WORK IN �P�'J � It THIS AREA — 1 THIS AREA 1 P-4 I IN s - I , �� CONTRACT N0. C19-59 U 13 •� \1t\\ l►\'1� N► Imp ���� ��� �IIMI�� 111011111111L ` l \-\\\\\ '- \\\\\ \\\\\\' \\\\\\- ‘ \-\\\\\\\\` ,I.\ -- ' 4" DRAWN BY A. NISHIHARA 1 r r " l w r • 1 w / w . " . " w 1 \\\\\\, I I / 40-6" / 7.-6" / 4'-6" / 7-g 4—6 / 7 --6 / 4'-e," / 7 -6 / 12'-8 1/2 I / CHECKED BY A. NISHIHARA SCALE 1/4" — 1'-0" PERMIT NO. SHEET NUMBER: REFLECTED CEILING PLAN FP1 C 1/4 -1 -0 ......„... 0' 2' 4' 8' 1 O E 1