Plans (4)
F PS20 19 -00013 SPRINKLER SYMBOLSSCOPE OF WORK SYMBOL STATUS BRAND SIN TYPE FINISH TEMP (F) ORIFICE THREAD 'ES" FACTOR NOTES _ TOT. C) NEW TYCO TY3531 SSP-QR Ch/Ch 155 1/2' 1/2" 5.6 -CONCEALED 24 1) The area of work shown is to have fire sprinkler drops installed in a new ceiling (ceiling by others) changes to the sprinkler system NI EXISTING TYCO TY3531 SSP-QR Ch/Ch 155 1/2' 1/2' 5.6 CONCEALED designed, fabricated and installed in accordance with NFPA 13 2013 and RECEIVED local standards. 2) The area of work is a mercantile space. JAN 3 0 201a HANGER KEY 3) This contract is limited to area of work shown. CITY OF i itar►iri T/ 51.1.1.1- O 1 Trimline Adjustable BUILDING t� e Band Hangar I11Ii�',ON / 2 " Threaded Rod GENERAL NOTES 3 ' Sammies for Metal 1) Area of work is to be protected as an Ordinary Hazard occupancy 2 4 Metal Structure per NFPA 13 2013. • 2) All materials devices and hangers used on this project shall be UL fri0 Listed and/or FM Approved for use in fire protection systems. 3) See attached 'Equipment Data Submittal' for allapplicable materials and equipment used in this project. VALIDITY OF PEFt THE 1,411 BASEDISSON ANCE CONSTRUCTIONOFAPERMIT 4) All new piping to be 1"black steel, Eddythread40 (or equivalent) DOCUMENTS AND OTHER with threaded ductile iron fittings cut in from existing heads. DATA SHALL NOT PREVENT THE CODE OFFICIAL FROM 5) Maximum spacing per head is as fisted in Sprinkler Symbol table. REQUIRING THE CORRECTION HANGER DETAIL 6) Any and all painting or paint preparation of piping to be by others. OF ERRORS. OSSC 105.4 NOT TO SCALE 7) Pipe hangers including on all armovers 2'—O" or longer to be installed in accordance with NFPA 13 2013 and per local AHJ. II 8) Sprinklers to be installed in accordance with NFPA 13 2013 and per the local AHJ. 8) All elevations measured from finished floor of existing building. PLEASE PROVIDE COMPLETED NFPA 13 10) If field conditions result in a change to the shop drawing MATERIAL AND TEST installation in any way, contact the project engineer to verify proposed 18'-3" changes are compliant with NFPA 13 requirements. CERTIFICATE AT /I v f- 11) This print or drawing shall be used only with reference to contracts FINAL INSPECTION of proposals of Wyatt Fire Protection, Inc. This print or drawing shall ADJACENT TENANT not be copied for, reproduced for nor exhibited to outside parties. This print or drawing and any and all copies therefore shall be returned to Wyatt Fire Protection, Inc. upon request. Nothing disclosed herein not publicly available shall be used without written permission from Wyatt -- , Fire Protection, Inc. \ igi OFFICE COPY 104 EXISTING TOILET ROOM CITY OF TIGARD """' M REVIEWED FOR CODE COMPLIANCE EXG' A.C.T. 8'-O" AFF -,o(R) Approved: ) E -SEM OTC: j I c-1 . (`��119 1 Permit#: F_ P Sa e) ) 103 EXISTING STOCK ROOM Address: `'� �'ksCA ori r d I ( 0 J EX By: � Date: a_. ! G- J EXG' A.C.T. 11 '-11 " AFF REVIEWED BY: • 59'_111 2'-6" / / / EX 101 SALES 5 GI 411 NEW GWB 13'-6" AFF 4 • I EX ADJACENT TENANT C08 cc o 1- X . _ cc © EXo rN O REVISIONS r I C-) 1 1/28/19 PERMIT CD 11) U v I - in 0 1, 0 --zi-- 102 NEW STOCK ROOM I 2 6- o 0 _ r T "T T 111111-r T T iii NEW A.C.T. 11 '-11 " AFF 011 '-10" AFF NEW GWBi X2' = o X / X II + + + + + II 8.-10-X. i 0 ,7) V III I I o V 111 0 T o T o o o —+ — MALL N III III1 LICONCOURSE I I -o NO. DATE DESCRIPTION1'-6'B'-2Y' € 0 + + + + + + += - + +III + —+ -I 1'-8"maw - 9'-Off AFF PC PANEL .44. 0 WVAT T / III X / X M / >< FIRE PROTECTION, INC. 1 I II I � 9095 S.W. Burnham T0 0 0 ' ' I 0 0 11 0 II I ° — 11 '-10" AFF NEW GWB ('503)84-2 283 1 1 1 = 1y 1 J2'-6- o 9095 SW BURNHAM ST -to" •—10" 3'-3' 3'-3' 3'-3" 1'-634• Iirai TIGARD, OREGON 97223 © 0 © (503)684-2928 1 1 I I 1 PROJECT: ---\ ' .. CASPER: WASHINGTON SERVICE SQUARE CORRIDOR CORRIDOR -- - 9685 SW WASHINGTON SQUARE RD SUITE C07 TIGARD, OREGON 97223 ADJACENT TENANT C06 JAMES M. BARB CONSTRUCTION, INC. 10701 RANCHITOS RD NE, ALBUQUERQUE, NM 87122 CONTRACT NO. 019-46 DRAWN BY A. NISHIHARA CHECKED BY A. NISHIHARA 79'-1 0" SCALE 1/4" = 11-0" / / PERMIT NO. REFLECTED CEILING PLAN SHEET NUMBER:LING 1 . 0 1/4"=1'-0" immoinuri 0' 2' 4' 8' 1 OF 1