Loading...
Permit (172) CITY OF TIGARD 7g'' `�p9f'aAm7 MASTER PERMIT ` COMMUNITY DEVELOPMENT 7//6/2,./ ,245 Permit#: MST2019-00163 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: May 23 2019 12:00AM Parcel: 1S135AA03800 Jurisdiction: Tigard Site address: 10404 SW AKILEAN TER Subdivision: OAK STREET CONDOMINIUMS Lot: 34 Project: Oak Street Condominiums, Lot 34 Project Description: New SFA. Building 5. 7/15/2020: REPRINT permit to add NC and heat pump. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 295 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 571 sf Garage: 275 sf Front: 0 Smoke Dwelling Units: 1 Third: 550 sf Right: 0 Detectors: Yes Total: 1416 sf Value: $181,730.60 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Drains: 0 Catch Basins: 0 Bcktlw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: Y Vent Fans: 3 Clothes Dryers: 1 Natural Gas Heat Pump: Y Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1416 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 11807 NE 99TH ST STE 1170 11807 NE 99TH STREET SUITE 1170 1 Ersn Cntrl 503-639-4175 VANCOUVER,WA 98682 VANCOUVER,WA 98682 2 2 Hour Fire Assemblies 3 1 Hour Fire Proofing PHONE: 360-258-7900 PHONE: 360-949-9128 FAX: 360-258-7901 Total Fees: $22,818.86 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OA 952-001 n0900...,Youummay obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: �C ' ��—� Permittee Signature: C'� �P�L re�7a� Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each Inspection. Mechanical� Permit ApplicatiRECE!vf 7--0 rq�F����OR�OFFICE ESE ONLY �p City Of Tigard ReceivDate/By:ed 7/5/0d 4t140 Permit Np 5 /9,-00/4,-J 13125 SW Hall Blvd.,Tigard,OR 97223 J U L 7 2020 Plan Review Phone: 503.718.2439 Fax: 503.598.1960 Date/By: Other Permit: TIGARD Inspection Line: 503.639.4175 CITY OF TIGARD Date Ready/By: saris: Pa ge See Pa e 2 for Internet: www.tigard-or.gov BUILDING DIVISION Notified/Method: Supplemental Information ,. Illy TYPE OF WORK 1- ` ' 1... OIAL FEE't,SCHEDULE— USE CHECKLIST ' Mechanical permit fees°are based on the value of the work I New construction ❑Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. Value:$ CATEGORY OF CONSTRUCTION RESIDENTIAL EQUIPMENTL YSI SFEES*, „ ,4 ® 1-and 2-family dwelling ❑Commercial/industrial ❑Accessory building For special information use checklist ❑Multi-family 0 Master builder El Other: Description Qty. Ea. Total JOB SITE INFORMATION AND LOCATION Heating/cooling: Air conditioning 1 46.75 Job site address:10404 SW Akilean Terrace Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 1 61.06 Suite/bldg./apt.no.: Project name: Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Subdivision:Cornerstone Condominiums Lot no.: 34 Other. 23.32 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 DESCRIPTION OF WORK Gas fireplace/insert 33.39 '"'°g' a""""""--""'''' Flue vent for water heater or gas NSFR attached /65 fireplace 23.32 Log lighter(gas) 23 32 'add A/C and mini-split to existing permit# MST2019-00 Wood pelletstove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 * la PROPERTY OWNER — I" , Environmental exhaust and ventilation: Name:Lennar NW Inc. Range hood/other kitchen equipment 33.39 Address:11807 NE 99th St. #1170 Clothes dryer exhaust 33.39 City/State/ZIP:Vancouver, WA 98682 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(360 )258-7900 Fax:( ) Attic/crawl space fans 23.32 I I APPLICANT ❑ CONTACT PERSON Other: 23.32 Fuel piping: Business name:Same as above $14.15 for first four;$4.03 for each additional Contact name:,JDiS Call Furnace,etc. Gas heat pump Address: Wall/suspended/unit heater City/State/ZIP: Water heater Phone:(360)258-7906 Fax::( ) Fireplace Range E-mail: juls.call@lennar.com Barbecue CONTRACTOR Clothes dryer(gas) Business name:HeatGuy, LIc. Other. MECHANICAL PERMIT FEES* Address:5215 NE 282nd Ave Subtotal /0 7 Jj City/State/ZIP:Camas, WA 98607 Minimum permit fee($90.00)Man review(25%of permit fee) Phone:(360 253 4822 Fax:( ) State surcharge(12%of permit fee) j'Q.,93 CCH lie.:187461 TOTAL PERMIT FEE 4dtp, 7 y This permit application expires if a permit is not obtained within 196 days after it has been accepted as complete. Authorized signature: ----- * Fee methodology set by Tri-County Building Industry Service Board Print name:Corinna Fri Date:04/15/2019 1:Building\Permas\MEC_Perndt App,040113.doe 440-4617T(I I/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Family Fee Schedule: Total Valuation: Permit Fee: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 CITY OF TIGARD MASTER PERMIT 1,1 :' COMMUNITY DEVELOPMENT Permit#: MST2019-00163 Date Issued: 05/23/2019 T FGAR L 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Parcel: 1 S135AA03800 Jurisdiction: Tigard Site address: 10404 SW AKILEAN TER Subdivision: OAK STREET CONDOMINIUMS Lot: 34 Project: Oak Street Condominiums, Lot 34 Project Description: New SFA. Building 5. BUILDING Floor Areas Required Setbacks Required Stories: 3 Bedrooms: 2 First: 295 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 34 Bathrooms: 3 Second: 571 sf Garage: 275 sf Front: 0 Smoke Dwelling Units: 1 Third: 550 sf Right: 0 Detectors: Yes Total: 1416 sf Value: $181,730.60 Rear: 0 PLUMBING Sinks: 1 Water Closets: 3 Washing Mach: 1 Laundry Trays: 0 Rain Drain: 1 Urinals: 0 Lavatories: 3 Dishwashers: 1 Floor Drains: 0 Sewer Lines: 100 SF Rain Storm Sewer: 100 Drains: 0 Tubs/Showers: 2 Garbage Disp: 1 Water Heaters: 1 Water Lines: 100 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 1 Hose Bib: 2 Backwater Value: 1 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 3 Clothes Dryers: 1 Natural Gas Heat Pump: N Hoods: 1 Other Units: 0 Furn<100K: 1 Vents: 0 Woodstoves: 0 Gas Outlets: 3 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 1 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 2 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: N Other Description: Ecompasing: Y BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: NEW SFA VB R-3 1416 Owner: Contractor: LENNAR NORTHWEST INC LENNAR NORTHWEST INC Required Items and Reports(Conditions) 11807 NE 99TH ST STE 1170 11807 NE 99TH STREET SUITE 1170 1 2 Hour Fire Assemblies VANCOUVER,WA 98682 VANCOUVER,WA 98682 2 1 Hour Fire Proofing 3 Ersn Cntrl 503-639-4175 PHONE: 360-258-7900 PHONE: 360-949-9128 FAX: 360-258-7901 Total Fees: $22,698.12 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. 2-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344. Issued By: "..._ Permittee Signature: \A—k C —ilO4r\ Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Building Permit Application 3* \---C--7 Residential „�, v FOR OFFICE ISE ONLY City of Tigard G. :ss EI V ED Received `i.i Date/By: 1\ 61 ()`r'° Permit No- l'-�' `�1,r t r 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Revlew l vv Phone: 503.718.2439 Fax: 503.598.19 S Other Permit \iL�ti t -u`` ' 41pF 3 U 2019 DateBy: ��' �1 T 1 G A K D Inspection Line: 503.639.4175 Date Ready/By: iii 1 Juris: I H See Page 2 for Internet: www.tigard-or.gov CITY I Y O F T I t 3 ii RD tified/Meth - / i Supplemental Information j„,L,-01442.r,:,:.. n -' :.... :. RFQU EED ATA L,,AND ! : - Building Permit Application Checklist One- and Two-Family Dwelling FOR OFFICE USE ONLY City of Tigard Received IllCity Date/By: Permit No.: 13125 SW Hall Blvd.,Tigard,OR 97223 Associ tedemuts: : ■ Phone: 503.718.2439 Fax: 503.598.1960 P 24-Hour Inspection Line: 503.639.4175 0 Electrical 0 Plumbing 0 Mechanical I"I G A K ll Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ ❑ 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 0 0 3 Verification of approved plat/lot. ❑ 0 0 4 Fire district approval required. Name of district: _ 0 El 0 5 Septic system permit or authorization for remodel. Existing system capacity ❑ CI 6 Sewer permit. ❑ ❑ ❑ 7 Water district approval. 0 ❑ 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ 0 0 9 Erosion control ❑plan El permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑ basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state Er El ❑ building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if g ❑ 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 El ❑ and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 ❑ furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- r❑ ❑ El floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. ✓❑ ❑ ❑ Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- El ❑ 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing © ❑ 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered ® ❑ 0 systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists [1 ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. © ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required 0 El ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or Q ❑ ❑ architect licensed in Ore•on and shall be shown to be a s,licable to the iro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ ❑ 24 Two(2)sets each are required for Items 16,19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. p ❑ ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, El ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9,1995. I:\Building\Pemuts\BUP-RESPermitApp.doc 02/24/2011 440-4613T(1 I/02/COM/WEB) RECEIVED - Mechanical Permit Applicauun FOR OFFICE USE ONLY City of Tigard APR 3 0 2019 Received Date/By: Permit No. �`j��1, V\(� S\ , ® 13125 SW Hall Blvd.,Tigard,OR 97223 Phone: 503.718.2439 Fax: 503.5981,1l1W0Y OF TIGARD Plan Review Date/By: Other Permit: TIGARD Inspection Line: 503.639.4175 BUILDING DIVISION Date Ready/By: auris: El See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information Vii' y 1 a, .® Mechanical permit fees*are based on the value of the work ®New construction El Addition/alteration/replacement performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. y GAG©RYOF COiSTRUCTION a; Value $ a.' TiESIDE i7 1I,EQLIIPIV E1!T;!SYSTI:1VIS'FEES* ® 1-and 2-family dwelling 0 Commerciallindustrial ❑Accessory building For special information use checklist. ❑Multi-family ❑Master builder El Other: Description Qty. Ea. Total Heating/cooling: .K, ����• =� JOBSlll±.�ORMATiON ANI) LOCATION„, ,, ��� . . Air conditioning 46.75 Job site address: 10404 SW Akilean Terrace Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP: Furnace 100,000+BTU(ducts/vents) 54.91 Heat pump 61.06 Suite/bldg./apt.no.: Project name: Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision:Cornerstone Condominiums Lot no.:34 Other fuel appliances: Tax map/parcel no.: Water heater 23.32 : Oga ' IESCRIPTIrON o womc` ` ': Gas fireplace/insert 33.39 Flue vent for water heater or gas NSFR attached fireplace 23.32 Log lighter(gas) 23.32 Wood/pellet stove 33.39 Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 Environmental exhaust and ventilation: Name:Lennar NW Inc. Range hood/other kitchen equipment 33.39 Address:11807 NE 99th St. #1170 Clothes dryer exhaust 33.39 City/State/LIP:Vancouver, WA 98682 Single-duct exhaust(bathrooms, toilet compartments,utility moms) 3 23.32 Phone:(360 )258-7900 Fax:( ) Attic/crawlspace fans 23.32 47„.7 Other: 23.32 Fuel piping: Business name:Same as above $14.15 for first four;$4.03 for each additional Contact name:JUIs Call Furnace,etc. Address: Gas heat pump Wall/suspended/unit heater City/State/ZIP: Water heater Phone:(360)258-7906 Fax::( ) Fireplace Range E-mail: juls.call@lennar.com Barbecue � '> .. COC $... s Clothes dryer(gas) Business name:HeatGuy, LIC. Other: Address:5215 NE 282nd Ave Subtotal city/State/ZIP:Camas, WA 98607 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(360 253 4822 Fax:( ) State surcharge(12%of permit fee) CCB lie.:187461 TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: - i * Fee methodology set by Tri-County Building Industry Service Board .. .Date-04/15/2019 I:\Building\Permits\MMEC_PermitApp_040113.doc 440-4617T(11/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 -Supplemental Information Commercial &Multi-Family Fee Schedule: 'Total Valuation '. Permit $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 RECEIVED - Electrical Permit Application APR 3 0 2019 FOR OFFICE USE ONLY City of Tigard Received II a 13125 SW Hall Blvd.,Tigard,OR 9722ITY�OF I IGARD Date/B g Plan Review IIPhone: 503.718.2439 Fax: 503.598. (DIN(.a DIVISION Date/B Related Permit#: T I GA RD Inspection Line: 503.639.4175 Ready Date/By: Jmis: Ed See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information ®New construction ❑Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition ❑Other: ❑Service or feeder 400 amps or more ❑Building over three stories. where the available fault current 0 Marinas and boatyards. :111]:':II CATEGORY>OF GNSTRUCTIQN '_ '�.,.-. , <,;. ,. exceeds 10,000 amps at 150 volts or 0 Floating buildings. ® 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agricultural amps for all other installations. buildings. 0 Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or 1 JOB'SITE,INFORMATIONAND,LOCATION = a'='' 1'-'1,41 .'. " 0 Emergency system. larger separately derived Job#: Job site address: 10404 SW Akilean Terrace ❑Addition ofnew motor load ofSyste"m I00HP or more. ❑"A,"E", ❑Six or more residential units. occupancy. City/State/ZIP: ❑Recreational vehicle arks. 0 Health-care facilities. P Suite/bldg./apt.#: Project name: 0 Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: > ,,',i,FEE SCHEDULE ;' Deuription I Qty. I Each .I Total New residential single-or multi-family dwelling unit. Subdivision:Cornerstone Condominiums Lot#:34 Includes attached garage. 1,000 sq.ft.or less 1 168.54 4 Tax map/parcel#: Ea.add'I 500 sq.ft.or portion 1 33.92 1 'DESCRIPTION OF WORK ,, Limited energy,residential 75.00 2 NSFR (with above sq.ft.) 1 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) RIlIkienewable Energy ❑ See Page 2 �; ®'PROPERTY,OWNER= .` , '❑ TENANT ? Services or feeders installation,alteration,and/or relocation Name:Lennar NW Inc. 200 amps or less 100.70 2 Address:11807 NE 99th St. #1170 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Vancouver, WA 98682 601 amps to 1,000 amps 301.04 2 Phone:(360)258-7900 Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 P Branch circuits—new,alteration,or extension,per panel -.: .„ '®_APLTCAN ❑ ONTAGT RERSO,N . : , A.Fee for branch circuits with Business name:Same as above above service or feeder fee, 7.42 2 each branch circuit Contact name:Ju Is Call B.Fee for branch circuits without service or feeder fee,first Address:Same as above branch circuit 56.18 2 City/State/ZIP: Each add'l branch circuit 7.42 2 (360 )258-7906 Fax:: Miscellaneous(service or feeder not included) Phone: ( ) Each manufactured or modular dwelling,service and or feeder 67.84 2 Email:julS call@lennar cora Reconnect only 67.84 2 �,. fig;; CONTRACTOR Pump or it igation circle 67.84 2 Business name: Three Phase Electric Sign or outline lighting 67.84 2 Signal circuit(s)or limited-energy Address: 11490 SE Jennifer St panel,alteration,or extension. 0 See Page 2 2 Each additional inspection over allowable in any of the above City/State/ZIP: Clackamas, OR 97015 Additional inspection(1 hr min) 66.25/hr Phone:(503) 908-8058 Fax:(503 ) 762-1823 Investigation(1 hr min) 90.00/hr Email: permits@ThreePhaseElectric.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 9000/hr CCB Lie.: 162368 Electrical Lie.: 3-332C I Suprv.Lic.: 6379S specifically listed('/hr min) Suprv.Electrician signature,required: i• LECTRIC?iAL PERMITjHi. r � c t Subtotal: Print name: Robert Lane Date: 0 Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Date: days after it has been accepted as complete. _ * Numhrrof, ctinnsallnl edperpcnmit. I:\Buildiri\Permits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015 440-4615T(l l/05/COM/WEB • Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: I 1i Fee for all residential systems combined: $75.00 Description t Qty. I Each IE. Total Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is charged at an hourly(1 hr min) 66.25/hr 1 Inspections for which no fee is 90.00/hr specifically listed(%2 hr min) COlVIMFRCIAL CORK OlYI�Y _; .,, ET,» fflCA1 r R r ES Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alain'.Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 __ RECEIVED APR 3 02019 CITY OF TIGARD Plumbing Permit ApplicationBUILDING DIVISION Building Fixtures FOR OFFICE t'al'. ONLY City of Tigard Received Date/By: PerndtNo.'\c OA1c,. 111 M 13125 SW Hall Blvd.,Tigard,OR 97223 at Pion Review 0 Phone: 503.7182439 Fax: 503.598.1960 DateBy Other PetnlitNo,: T t G A R D Inspection Line: 503.639.4175 Date Ready/By: June. Bf See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information TYPE OF"WORK. • :FEET.SCHEDULE ®New construction ❑Demolition For special infonuntion use checklist. Description I Qty. I Ea. I Total ❑Addition/alteration/replacement ❑Other: New I-2-family dwellings(includes 100 ii.for each utility connection) CATEGORY OF CONSTRUCTION • SFR(1)bath 312.70 ❑1-and 2-family dwelling 0 Commercial/industrial SFR(2)bath 437.78 SFR(3)bath500.32 ❑Accessory building ®Multi-family 1 0 Master builderEach additional bath/kitchen 25.02 0 Other: Fire sprinkler(_sq.]t.) Page 2 .':JOB SITE.INFORMATION AND LOCATION Site utilities: Job site address: 10404 SW Akilean Terrace Catch basin or area drain 18.76 Drywell,leach tine,or trench drain 18.76 City/State/ZIP:Tigard, OR 97223 Footing drain(no.Imear ft.: ) Page 2 Suite/bldg./apt.no.: 1 Project name: Manufactured home utilities 50.03 Cross street/directions to job site: Manholes 18.76 Rain drain connector 18.76 Sanitary sewer(no.linear ft.:_____) Page 2 Storm sewer(no.linear It.: ) Page 2 Water service(no.linear It.: ) Page 2 Subdivision:Touchstone Condominiums 1 Lot no.: 34 Fixture or item: Tax map/parcel no.: Backflow preventer 31.27 *DESCRIPTION OF WORK backwater valve 12.51 Clothes washer 25.02 --- Dishwasher 25.02 Drinking fountain 25.02 Ejectors/sump 25.02 21 PROPERTY OWNER. .' 1 ` :0 TENANT ''. '..• Expansion tank 12.5E Name:Lennar NW Inc. Fixture/sewer cap 25.02 Address:11807 NE 99th St.#1170 Floor drain/floor sink/hub 25.02 Garbage disposal 25.02 City/State/ZIP:Vancouver,WA 98682 Hose bib 25.02 _ Phone:(360)258-7906 Fax:( ) Ice maker 12.51 E APPLICANT • 0 CONTACT PERSON interceptor/grease trap 25.02 Business name:Lennar NW Inc. Medical gas(value:$__ ) Page 2 Primer 12.51 Contact name:Jule Cali Roof drain(commercial) 12.51 Address:SAME AS ABOVE Sink/basin/lavatory 25.02 City/State/ZIP: Solar units(potable water) 6254 Phone:( ) Fax::( ) Tub/shower/shower pan 12.51 E-mail:juls.call@lennar.com Urinal 25.02 CONTRACTOR Water closet 25,02 Water heater 37.52 Business name: If> 04.±- e"r Vl c,e--__S [lo,/ t Water piping/DWV 56.29 Address: i ©'7.S ry' We 1'2Iortc. Coir.vghsq Ue( (ytVc" Other: 25.02 City/StatetZIP: Tax,4--o c(k 0_12.-- q 7 C) 60 Subtotal Phone:(,$O3) b C 7 Hi 11 Fax:(5o 3) 66 -7_4 q `1f Minimum permit fee: $72.50 Plan review(25%of permit fee) CCB Lie.: (I 2 2Z.© Plumbing Lie,no.:2 6_I,2)/ pt State surcharge(12%of permit fbe) Authorized signature: .3 ( TOTAL PERMIT FEE Print name: Q lit.-el / 4, b-e-"f Date: i i 2¶j i Ct This permit application expires irk permit is not obtained within 180 days 1 ` after it hos been accepted as complete. "Fee methodology set by Tri-County Building Industry Service Board. 1 ttauildiaglP4rmits1PLMU-fern iaApp.doe 10/0180 -061 9 4.106Tt10102/COdtrWCtI I 1 i • Plumbing Permit Application - City of Tigard Page 2 -Supplemental Information Fee Schedule: Residential Fire Suppression Systems: Site Utilities Qty Fee(ea) Total Square Footage: Permit Fee:. Footing drain-1"100' 50.03 0 to 2,000 $121.90 Footing drain-each additional 100' 37.52 2,001 to 3,600 $169.69 3,601 to 7,200 $233.20 Sewwer-1st 100' 62.54 7,201 and greater $327.54 Sewer-each additional 100' 37.52 Water Service-1st 100' 62.54 Medical Gas Systems: Water Service-each additional 100' 37.52 ;Valuation: Permit Fee: Storm&Rain Drain-1st 100' 62.54 $1.00 to$5,000.00 Minimum fee$72.50 Storm&Rain Drain-each additional 100' 37.52 $5,001.00 to$10,000.00 $72.50 for the first$5,000.00 and$1.52 for Other.Inspections or Fees Qty. Fee(ea) Total each additional$100.00 or fraction thereof,to • and including$10,000.00. Inspection of existing plumbing or for $10,001.00 to$25,000.00 $148.50 for the first$10,000.00 and$1.54 for which no fee is specifically indicated 90.00/hr (minimum charge-1/2 hour) eachadditional$100.00 or fraction thereof,to anddincluding$25,000.00. Inspections outside of normal business 90.00/hr $25,001.00 to$50,000.00 $379.50 for the first$25,000.00 and$1.45 for hours(minimum charge-2 hours) each additional$100.00 or fraction thereof,to Reinspection Fees 90.00/hr and including$50,000.00. Additional plan review for revisions 90.00/hr $50,001.00 and up $742.00 for the first$50,000.00 and$1.20 for (minimum charge 1/2 hour) each additional$100.00 or fraction thereof. Subtotal: Commercial Fixture Work: Are you capping,adding or replacing fixtures? If"yes", please indicate work performed by fixture. Failure to accurately report fixtures could result in increased sewer fees*. Quantify by Fixture Type Plan Review for Plumbing Installations Fixture Type for rooked Plan review is required for anyof the following. Work Performed: Capped Added Relocate Pleaseacheck all quite t Baptistry/Font apply. Rath -Tub/Shower ❑ Any new commercial building with water service 2"and Jacuzzi/Whirlpool greater,except systems designed and stamped by licensed Car Wash -Each Stall engineer. -Drive 77uu ❑ New exterior plumbing site utilities for any complex structure Cuspidor/Water Aspirator as defined in OAR9 18-7 80-0040. Dishwasher -Commercial ❑ Medical gas and vacuum systems for health care facilities, -Domestic ❑ Any multipurpose fire sprinkler system, Drinking Fountain 0 Any complex structure as defined in OAR9 18-780-0040. Eye Wash Floor Drain/sink -2" Submit 2 sets of plans with any of the above. -3" -4" Isometric or Riser Diagram Car Wash Drain Garbage Domestic-non-Food 0 Isometric or riser diagram is required for new buildings Disposal -Domestic-food related that meet the qualifications above. -Commercial-food related -Industrial-food related Ice Maeh./Refrig.Drains Oil Separator(Gas Station) Comments regarding fixture work: Rec.Vehicle Dump Station Shower -Gang -Stall Sink/Lay -Non-food related -Bradley • -Commercial-food related -Service Swimming Pool Filter *Note: If the fixture work under this permit results in an Washer-Clothes Water Extractor increase of sewer CDUs,a sewer permit will be issued and Water Closet-Toilet fees assessed for the sewer increase must be paid before the Urinal plumbing permit can be issued. Other Fixtures: C:Wsers\JuCall\Downloads\PLMF_PermitApp.doe 2 City of Tigard a COMMUNITY DEVELOPMENT DEPARTMENT 1 T 1 c A lz n Building Permit Review — Commercial - With Land Use Building Permit #: \Ck- COL?- Site Address: I/0 '''-/ 7- Suite/Bldg#: g271 Project Name: OOP' Cit,ELI ar dL,S' i iii/d iva 'C--- (Name c(Name of commercial business occupying the space. If vacant, V/ entz ec Space.) Planning Review L Proposal: /U-A) C-erii ii_P v i h r tml 1 -rify site address/suite# exists and active in permit syst . hi#•'ver Terrace Neighborhood: ❑ Yes No ri ndUseCase#: Ai C6,2010 -- f7)iz'.2 Plan atch Approved Land Use: ,_ MAr Site Plan Lld andscape Plan er: 1 ii `'drban Forestry Plan 121 Elevation Plan ri wilding Height: M mum Height Actual Height ,g171 Conditions Met: i Prior to Submittal ❑ Prior to Permit Issuance Business License: O ,Exists: 0 Yes 0 No,applicant notified to obtain business license Nublic Facilities Improvement(PFI)Permit: Required: 0 Yes,applicant was notified hd No Applied For: 0 Yes 0 No,stop intake Notes: Approved by Planning: %!� Date: " Revisions (after Building Submittal only) Reviewer Date Revision 1: 0 Approved 0 Not Approved Revision 2: 0 Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved Building Permit Submittal Original Submittal Date: t"\''35l)k\q Site Plans: # ,3 Building Plans: # 3 Building Permit#: V Enter building permit#above. Workflow Routing: Cr Planning Cr Engineering Permit Coordinator Er/Building Workflow Sign-off: Et/ Sign-off for Planning(include notes from planning review) Route Application Documents: [2'Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: ._,,24,./\_,ti� Date: '3\,I WI I:\Building\Forms\BldgPennitRvw COM_WithLandUse_060116.docx Engineering Review Slope at building pad: kfr PFI Permit#: ICJ Conditions "Met"prior to issuance of building permit Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) a-Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: ❑ Yes Er No Assess Water Quantity Fee in-lieu: ❑ Yes No LIDA Facility on lot: ❑ Yes ErNo ❑ NOT Approved by Engineering: Date Notes: Approved by Engineering: A/14— !.c_) ` Date:5/6 777 Revisions (after Building Submittal only) Reviewer Date Revision 1: ❑ Approved ❑ Not Approved Revision 2: ❑ Approved ❑ Not Approved Revision 3: ❑ Approved ❑ Not Approved Permit Coordinator Review ❑ Conditions "Met"prior to issuance of building permit ❑ Approved,NOT Released: Date: Notes: Revisions (after Building Submittal only) Revision Notice 1: Date Sent to Applicant: Revision Notice 2: Date Sent to Applicant: Revision Notice 3: Date Sent to Applicant: 'DC Fees Entered: Wash Co Trans Dev Tax: es CI N/A Tigard Trans SDC: [es 0 N/A Parks SDC: Di Yes ❑ N/A __ -Oil to Issue Permit Approved by Permit Coordinator: Date: 51141T I:\Building\Fonns\BldgPern itRvw_COM_WithLandUse_070915.docx FOR OFFICE USE ONLY—SITE ADDRESS: This form is recognized by most building departments in the Tri-County area for transmitting information. Please complete this form when submitting information for plan review responses and revisions. This form and the information it provides helps the review process and response to your project. City of Tigard • COMMUNITY DEVELOPMENT DEPARTMENT IFIa Transmittal Letter TIGARD 13125 SW Hall Blvd. • Tigard, Oregon 97223 • 503.718.2439 • www.tigard-or.gov TO: DATE RECEIVED: DEPT: BUILDING DIVISION RECEIVED c C E'� `c FROM: Juls Call JUN - 6 2019 CITY OF TIGARD COMPANY: Lennar NW Inc. BUILDING DIVISI N PHONE: 360-258-7906 By: RE: 10404 SW Akilean Terrace LOT 34 MST2019-0016 (Permit Number) Oak Street Condos (Project name or subdivision name and lot number) ATTACHED ARE THE FOLLOWING ITEMS: Copies: Description:` Copies: Desc 't tion: Additional set(s) of plans. 2 • isions: see attached Cross section(s)and details. Wall bracing and/or lateral analysis. Floor/roof framing. Basement and retaining walls. Beam calculations. b Engineer's calculations. Other(explain): i- RE : see attached document 1 h it FO, O FICE USE ONLY Routed to Permit Tec i n: ate: Initials: PIT Fees Due: ❑ Yes ill Nty' Fee Desc n: Amount Due: p $ 5Z/ / por) . $ , „Spec•. In :tions: 'eprint Permit(per PE): ❑ Yes ❑ Done Applicant Notified: y---- Date: Ze/14i7pi,,,,, --- Initials:// I:\Building\Porins\TransmittalLetter-Revisions.doc 05125/20I2 Cornerstone at Washington Square 4/25/19 Major updates—will apply to building 3,4 and 5. Reduced depth of I joists from 16"to 11 7/8". Detail 3/S2.02 3 layers of rim removed and replaced with 3 continuous solid 2x blocking. I joists hung from end blocking with face—mount hanger. New joist layouts provided. Floor sheathing reduced to 7/8"thickness with an APA 60/32 span rating. Site Plans updated to match placement of building on AKS approved landscape plan. Clarify/update details—per trade partner's questions. Revised details will be applied to buildings 3,4 and 5. 1. Steel Column 10/S5.01 2. Clarify location of vapor barrier 51.01b—only in living spaces. Removed note from garage area and replaced with 4"concrete slab on 6"min compacted gravel at garage and carport. 3. Identified location of worse case uplift and reduced depth of grade beam from 7'to 2'-6" 8/55.03 4. Unused details from set for clarity-55.04-details 2&3 5. Detail 3/S5.02 updated to show correct fire proofing(2) layers of 5/8"type'X' sheathing. 6. Detail 5/S5.04—updated to show correct type x sheathing 7. Balconies details updated on A5.02—Detail 2, 3 and 7.—Detail 12/S5.02 removed. Update elevations—to match window grids of existing buildings. Balcony dimensions corrected—were not matching—Sheet A1.02 and A5.02 depth is 3'-0" Update to electrical layout for consistency 8. Entry door lights 9. Sconce in stairs well. City of Tigard 71 COMMUNITY DEVELOPMENT DEPARTMENT . I 11 c RBuilding Permit Review — Commercial - With Land Use Building Permit #: rn�c 1CA- W.Lt... Site Address: J,9 I/O 1/ -gl 4 g �r- Suite/Bldg#: gi-/ Project Name: Oai- ‘.5? p71- (�,�,1 el/of iclti/ding - , �� e of commercial business occupying the space. If vacant,entt9 Space.) Planning Review 1S 1k)N la‘tQ t k;'. 11.71ti1,VVV► '\c`+p Proposal: k) C'.trild l i thmunii 1 Zrify site address/suite#exists and active in permit syst . V°.'' er Terrace Neighborhood: ❑ Yes Z No �F� nd Use Case#: 114Aih 2O 16 --- ()(fl2 (,) 11J Plan tch Approved Land Use:32�// ►j�� Site Plan Od dscape Plan 1.Q t )ther. male d rban Forestry Plan 121 Elevation Plan rA uilding Height •. i•um Height -9."c— Actual Height .g1"/ V Conditions Met F. Prior to Submittal ❑ Prior to Permit Issuance 01. usiness License: ,,ppEExists: ❑ Yes 0 No,applicant notified to obtain business license '1Bublic Facilities Improvement(PFI)Permit. Required: 0 Yes,applicant was notified 1d No Applied For: 0 Yes 0 No,stopintake Pp Notes: Approved by Planning .." 74Date: /i Ii Revisions(after Bu' . Submittal only) Revi er D e Revision 1: Approved 0 Not Approved — ��p /i ' Revision 2: ❑ Approved 0 Not Approved Revision 3: 0 Approved 0 Not Approved Building Permit Submittal Original Submittal Date: ikt2'‘q Site Plans: # ?› Building Plans: # 3 Building Permit#: Egi/Enter building permit#above. Workflow Routing. P1 Planning 2/Engineering Permit Coordinator D'Building Workflow Sign-off: 12"Sign-off for Planning(include notes from planning review) Route Application Documents: 2/Building: original permit application,site plans,building plans,engineer and beam calculations and trust details,if applicable,etc. Notes: By Permit Technician: .�.�. J...._ Date: t t Wit I:\Build ngWorms\BldgPamitRvw COM WithIandUse 060116.docx Engineering Review4 /u„ Er Slope at building pad: Er PFI Permit#: ErConditions"Met"prior to issuance of building permit Ja"Easements (encroachments)per engineering conditions of approval and plat(not typical on SDR/CUP) D-Water Quality/Quantity Facility: Assess Water Quality Fee in-lieu: 0 Yes .ef No Assess Water Quantity Fee in-lieu: 0 Yes �' No LIDA Facility on lot 0 Yes E No 0 NOT Approved by Engineering: Date Notes: Approved by Engineering: /k114- Lc- • Date:57 6 7/7 Revisions(after Building Submittal only) Reviewer Date Revision 1: Cd'Approved 0 Not Approved 4,5 Revision 2: 0 Approved ❑ Not Approved Revision 3: 0 Approved 0 Not Approved Permit Coordinator Review ❑ Conditions"Met"prior to issuance of building permit 0 Approved,NOT Released: Date: Notes: Revisions(after Building Submittal only) Revision Notice 1: Date Sent to Applicant Revision Notice 2: Date Sent to Applicant Revision Notice 3: Date Sent to Applicant: IDC Fees Entered: Wash Co Trans Dev Tax: es 0 N/A Tigard Trans SDC: �es 0 N/A Parks SDC: Ei Yes 0 N/A c ) (? 101E. to Issue Permit Approved by Permit Coordinators Date: 5J ' 1 I:\Buitding\Forms\B1dgPermitRvw_COM WithLandUse 070915.dcex