Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (185)
CITY OF TIGARD MASTER PERMIT : s COMMUNITY DEVELOPMENT Permit#: MST2019-00179 13125 SW Halland OR 97223 503.718.2439 Date Issued: 05/20/2019 T f r.A I.I.7 Blvd.,Tigard Parcel: 1S134CC01200 Jurisdiction: Tigard Site address: 12150 SW MERESTONE CT Subdivision: MERESTONE Lot: 11 Project: Tam Project Description: Solar photovoltaic. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 of Value: $10,115.47 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV 4.65 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: OTR SF VB R-3 0 Owner: Contractor: TAM,PAULO&CHING Y BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) 12150 SW MERESTONE CT 1220 S 630 EAST,STE 430 TIGARD,OR 97223 AMERICAN FORK,UT 84003 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $321.88 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION,Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010th .ugh'OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 50.22232. !: •r ..:00. 2.2344. ,I / g Issued �/ Permittee Signature: A Call 503.639.4175 by 7:00 a.m.for the next available inspection date. permit c This ard shall be kept in a conspicuous place on the job site until completion of the prom Building Permit Application Residential , ., FOR OFFICE USE ONLY Cl of Tigard Received - `J gPermit No. II " 13125 SW Hall Blvd.,Tigard,OR 97223 1NI` '' 0 , 2019 Date/By: \ Cy i< 1-r \ g , + an Review I Apr Other Permit: Phone: 503.718.2439 Fax: 503.598.1960 Date/By: T I G A R D Inspection Line: 503.639.4175 3,)D.e Ready/By. Juris: ® See Page 2 for Internet: www.tigard-or.gov j i,9 i ,_,t + - '1.tified/Method: ? Supplemental Information L/. /r<� ❑New construction ❑Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all L ddition/alteration/replacement ❑Other 4+6R r; } : 1r ,'. o world ofit for the equipment,materials verhead anthe prk.inicated on thisapplication.d.._..... and 2-family dwellingValuation: $ 10,115.47 ❑Commercial/industrial 0 Accessory building 0 Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms: 400 t Tl € ilCO) iiii01*I Total number of floors: Job site address: 12150 SW Merestone Ct,Tigard, Oregon, 97223, United States New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Paul Tam Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet ViiL i ill€ ' 'zti M - . Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and ptheprofit for the r l IC work indicated on this application. Rooftop Solar PV Valuation: $ Existing building area: square feet New building area: square feet Name: Paul Tam Type of construction: Address:12150 SW Merestone Ct,Tigard,Oregon,97223,United States Occupancy groups: City/State/ZIP: Existing: Phone:( ) Fax ( ) New: Business name:Blue Raven Solar Contact name: Lesly Bee Structural plan review fee(or deposit): FLS plan review fee(if applicable): Address: 1220 S 630 E City/State/ZIP: American Fork UT, 84003 Total fees due upon application: Phone:(3853482-0045 Fax::( ) Amount received: E-mail: permitting.deparment@blueravensolar.com " + ' ' ` I i - Commercial and residential prescriptive installation of ' T roof-top mounted PhotoVoltaic Solar Panel System. Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details Address: 1220 S 630E and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP: American Fork UT, 84003 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(385482-0045 Fax:( ) State surcharge(12%of permit fee): $21.60 CCB lie.:210112 Total fee due upon application: $201.60 Authorized signature: Yetru,o 4,c, This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Jeffrey Lee Date: 05/02/2019 *Fee methodology set by Tri-County Building Industry Service Board. I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB) Electrical Permit Application FOR OFFICE: USE ONLY' • Received r''' ' City of Tigard DateB :II Permit#: a 13125 SW Hall Blvd.,Tigard,OR 97223 Plan Review Related Permit#:��" j( ( � • Phone: 503.718.2439 Fax: 503.598.1960 DateB T 1 GA RD Inspection Line: 503.639.4175 Ready Date/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information 'IIIIIFIIIIIIIIIIIRRIIIIMIIIIIIIIMIIINEIMIIIIRIIIIIIIIIIIIIIIIIIIIIIIIIIIRI *SVP,'.: WQ 0 New construction ©Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Demolition 0 Other: ❑Service or feeder 400 amps or more ❑Building over three stories. Demolition where the available fault current 0 Marinas and boatyards. III AT c4.,_ I exceeds 10,000 amps at 150 volts or ❑Floating buildings. 9 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural 0 Multi-family ❑Master builder 0 Other: ❑Fire pump.all other installations. Instd latio KVA or .. } l "• D: SEmergency system. lazgerspar t ly de ved Job#: Job site address: 12150 SW Merestone Ct, Tigard, Orec ❑Addition of new motor load of system. 100HP or more, ❑"A","E","1-2","1-3", City/State/ZIP: ❑Six or more residential units. occupancy. El Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: Project name: Paul Tam ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: °. Description 1 Qty. I Each I Total I * New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel 4: Ea.add'l 500 sq.ft.or portion 33.92 1 :................................................... .........::..........:............. :ss;:;_:...-.:::...... :,....,............. L hal •r-••-•• '"""""" imitedenergy residen' Rooftop Solar PV (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) ::::•:::_::::::::::::::: :;::-:: :::..::::..........:..::::::::::..::::::-::::::....,..........:�::::::::::::::::::::::::�:-. ,..._......................:•::-:::;::::::......:....,................ Renewable Energy I=1 See Page 2 Services or feeders installation,alteration,and/or relocation Name: Paul Tam 200 amps or less 100.70 2 Address: 12150 SW Merestone Ct, Tigard, Oregon, 97223, United States 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 �::::: :sss;:>:=<,:aa:es:;v..: >: . ... s:::.t::::r::.@;siiiiE<=aa:;:as::::.::a_....¢: .;,,....,._..;.,;.....:-:.:::::::::::::::::�:;::.:r 'ilk': ranch clrcm —n i:::::.. ::::.....x<..mr:.:., is ew,alteration,or extension,Per panel ::, €s ._._..__A 11 ,r::::::::::.:::::::::: .............. :•:::::::_:•:::::::::::::::,... .. ....:•:-:::........._.,.......................,:•::::::::::::::::::,:: ......,..,,... A Feeforbranchcircuitswith Business name: Blue Raven Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: B.Fee for branch circuits without Address: 1220 S 630 E service or feeder fee,first 56.18 2 branch circuit City/State/ZIP: American Fork, UT 84003 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385)182-0045 Fax: :( ) Each manufactured or modular 67.84 2 Email: permitting.department@blueravensolar.com dwelling,service and/or feeder ::. ..._ ......._`;...�..�.;.=.isis.i.i.i.i..,: -;iii;t�i,....._:....................-_..............:.........,.....,.-......,:: Rueconner clt only on circ e 67.84 2 ::: :: :::.. , : :::: w ;:_.. . . ,.,.' , ¢ € P mp o 'n•i at 1 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Address: 1220 S 630E Signal circuit(s)or limited-energy El See Page 2 2 panel,alteration,or extension. Each additional inspection over allowable in any of the above city/State/zIP: American Fork, UT 84003 Additional inspection(1 hr min) 66.25/hr Phone:(385 482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lic.:210112 Electrical Lic.: C1214 Suprv.Lic.: 6097S specifically listed(/2 hr min) E2.2 r. Suprv.Electrician signature,required: S „,,,,/ ' y Subtotal: Print name: Sam Collier Date: 05/02/2019 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): t e'.6.4 Authorized signature: ° TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Jeff Lee , nate. 05/02/2019 days after it has been accepted>ts complete. * Number of inspections allowed per permit. 1:\Building\Permits\ELC_PennitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2=Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: Desc.,, ...... ..... .. ......., ... I Qty. I Each I Total I * Renewable for all residential systems combined: $75.00 en won Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 1 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 E Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva—no additional charge 0.0 3 Each additional inspection over allowable in any of the above: ❑ Other: Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for hich hrnomin�fee is 90.00/hr specically listed Subtotal(Enter on Page 1): Fee for each commercial system: $75.00 * Number of inspections allowed per permit. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:\Building\Permits\ELC_PermitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard Building Division :111 I 13125 SW Hall Blvd, Tigard, OR 97223 Phone: 503.718.2439 Fax: 503.598.1960 rsr�.: 0 3 2019 TI G A R D Inspection Line: 503.639.4175 C , ,�ARD www.tigard-or.gov BUIL_ , d's 3rd 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12150 SW Merestone Ct, Tigard, Oregon, 97223, United Sta City: Zip: Owner's Name: Paul Tam Date: 05/02/2019 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation El Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. Is the wind exposure Yes If"Yes", qualifies for Wind Exposure "C"or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes C7 Yes the prescriptive path. and/or their accessory Ground structures. El No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than D' Yes If"Yes", qualifies for the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx Is the construction material wood and does 0 Yes "Yes",of If Yes , qualifies for Construction the construction qualify p p p as "conventional light ❑ No the rescri tive ath. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. p Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? If"Yes", qualifies for Nominal lumber. In Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance 0 Yes « with Section 305.4(3) of If Yes , qualifies for the 2010 Oregon Solar ❑ No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. CNI of composition shingle. Is the roof mounted p Yes Connections of solar assembly If"Yes", the solar assembly connected to roof No qualifies for to the roof framing or blocking ❑ the prescriptive path. directly? 2 I:/Building/Forms/Photovoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mountedMinimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the standing seam prescriptive path. metalanels If the width of the panel P Width of roofing is less than 18 inches, panels? 18 inches or less inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. '/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12"o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for module to the roof Yes the prescriptive path. solar modules p p surface. ❑ No 3 I:/Building/Forms/PhotoV oltaic-Checklist02-01-11.docx V Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing(rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: JinKO Solar Eagle Model Number: 15 Listing Agency: CSA 4 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 12150 SW MERESTONE CT, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2019-00179 Inspection Type: Inspector: 199 Electrical final David Young Result: PASS Comments: Violation Summary: Inspector Contractor