Loading...
Plans RECEIVED APR 162019 CITY OF TIGARD BUILDING DIVISION Building Plans for City of Tigard Building Permit Application Customer: The Fountains at Summerfield condominiums HOA 15685 SW 116th Ave., #105 Tigard, OR 97224 Contact - Paul Brock, 858-212-9105, pbrock987Pgmail.com OFFICE COPY Contractor: Jon Erickson, 503-730-9220 ion.eveniobsPamail.com CCB 162397 CITY OF TJC R1 REVIEWED FOR COD. COMFFL[ANCE Scope of Work— Repair Decks Approved: N • Replace perimeter joists with PT DTC' • Repair joist and soffit dry rot Penult#: �l�,n�Qy� _ ppp9 • Re-coat deck surface with Gaco Address: j 7 3 J ) 9. • Replace 42" guardrail and infill to comply with Suite th 06 IBC multi-family code By: - Date: Li-,3D ._ 1 File Location: Fountains Deck Permit Plans REVISED.pptx $UBJ4CT TCWood structural members that ar REVIEw exposed to the weather to be Pressure Treated or decay resistant per 317.1.3 4/16/19 Fountains at Summerfield - Deck Building Plans 1 Typical Deck Construction and Size — 102 SF Brick Col. 114.5" 1$x"45Imbedded 6x6 PT n E..---- 4x4 PT Posts A LP E -1 2 x 8 PT blocking between joists attached with Three 16D 3-1/2"n HDG >< >< ' Ref: 2014 Oregon Structural 43" 115" 56.5" Specialty Code—Table 2304.9.1-29 2"x8"Joists 16" OC Blocking supports Simpson Rim joist attached to Tension Ties DTT2Z. Two lateral joists with / DTT2Z brackets required for Three 16D 3-1/2"n HDG posts in this position. See Beam 6"x10" Simpson Wood Connection Ref: 2014 Oregon Connectors 2018-18 Deck Structural Specialty Tension Ties— page 337 Code—Table of 2304.9.1-29 House—Brick exterior , 43" Scale— 12"/increment LJ 4/16/19 Fountains at Summerfield - Deck Building Plans 2 Water Penetration Remediation — Cross Section Posts—4x4 PT Flashing 2" x 3" VResurfacing material 3/4" exterior plywood decking 0 E E 00 x N _'' '---J Hardi-plank Fascia 9.25" x .25". Applied with exterior adhesive and secured with post bolts. Wicking protection for soffit provided by%" extension. Pre-paint before adding flashing %z" plywood soffit 777' Scale— 1" increment 4/16/19 Fountains at Summerfield - Deck Building Plans 3 Guard Rail Post — Simpson Tension Ties Posts—4x4 PT tiE Simpson DDT2Z " i N Attach to lateral joist with \\\\\ mow. 8 SDS 1.5" screws j � t x 6 Machine Bolt � DTT2Z supports 1800 lb. 1/2"HDG with nuts and tension load. Meets IBC washers Code for multi-family deck 00 guardrails. (-V E Refer to attached Simpson °C catalog - Deck Tension Ties Lateral Joist page 337 Also refer to Simpson code- compliant Guardrail Post Connection bulletin T-C-GRDRLPST17 Scale— 1" increment niminne 4/16/19 Fountains at Summerfield - Deck Building Plans 4 Typical Guardrail and Infill Section — 50" max. between posts Simpson Strong Drive Wide Screw SDWS 4", Railing 2 x 4 TKC O 2 3/8"TL. Two per Cap Rail —Trex I etd1/ end,three in mid span 1" x 5.5" ' i, attached to Railing with i. : �,� ti -- � � exterior ',V4146',-,'',201F,° t F adhesive. �; �� �„: , %n h Railing Support IA 2x4TKC . a ;, t. , ' / oo Attached to a c,iRailing and X Installation of Posts with sr a a balasters and rails adhesive and 'i` ,. per mfg installation Simpson instructions. Strong Drive Wide Screw SDWS 4", Railing 2 x 4 TKC Railing Infill - 2 3/8"TL. DecKorator aluminum V 2.75" space balaster%" x 32". Spacing 3.75" DecKorator Scale 1" increments CodeCompliance Research Report I ` J 1 ' " " " I CCRR-0161 4/16/19 Fountains at Summerfield - Deck Building Plans 5 of 5