Plans (112) X3 t It-kuj\ (--A, ') i'C:c.,i `\Q... `Itl, `
7
RECEIVED
MAY 142019
_____J- , .
CITY OF TIGARD
%l.HHI.DING DIVISION
i
I
a8'
- OFFICE COPY
BNea��'a�s I- Area �
I
Food Pref 'Idea
El--i se0 EF--
11
F11 11 All
II
54` ' wi a,5")(fa fi
! abgVa, 4- Cor-;do >
r; Cavil(ad-AL L Cofq'tdoe 6. e ra i-i o,v s - Tyrt,
Equipment Schedule
j, TAG EF-1,2
. Manufacture Panasonic
t
I Model FV-0510VS1
` •- 7`(. MBTUH
HSPF
SON ES
i I CFM 80
i Voltage 115, 1ph
l CiCISTt�i E�<11At1. i MOCP 15
f
1 Co,twel ! _ _2
Weight 8.82 lbs.
[L. �-- M - ` -' _ Location Ceiling Mounted
E
l i Notes
(ED LoUVeN
Project: Quality Inn
k\'\V Location: 11460 SW Pacific Hwy., Tigard Or. 97223
Heat Removal - Exhaust for Kitchen Prep Area
Scale: 1/8" = 1'0" Plan Sheet
Drawn By: Date: 5/10/2019 (Rev. M-1
Vl hisper` °DC- EGEIVED FV-0510VS1
VENSpecification Submittal Data/Panasonic Ventilation Fan MAY 14 20 9 4"Oval duct
Description: Ceiling Radiation Damper:. , wi-
- �G!RD
Ventilating fan shall be Low Noise ceiling or wall •WhisperValue DC is UL Ilst4° •r r se, p.thp ith, ,mount type rated for continuous run.Fan shall Panasonic Ceiling Radiatlo417;, sue- Me110:IVI'�ION ,��
be ENERGY STAR°rated and certified by the PC-R005C5,sold separately). �-
Home Ventilation Institute(HVI).Evaluated by Grille: " �/'
Underwriters Laboratories and conform to both
UL and cUL safety standards. •Attractive design using Poly Pro material.
•Attaches directly to housing with torsion
Motor/Blower: springs. �.
•Enclosed DC brushless ECM motor Warranty:
i
technology rated for continuous run. •DC Motor:6 Years from original purchase
•Fan ventilation rates All be manually date. FV-0510VS1
adjustable for 50-80-100 CFM. •ALL Parts:3 Years from original purchase
•Power rating shall be 120 volts and 60 Hz, date. 120V/60Hz.Duct diameter shall be no less
•Fan shall be UL and cUL listed for tub/shower
enclosure when GFCI protected and used in Architectural Specifications: than 4".Optional 24 gauge steel,fire code
insulated ceiling(TYPE I.C.). Ventilation fan shall be UL and cUL listed for rated 4'oval to 3'round duct adaptor sold
•PCB board equipped with thermal-cutoff ceiling or watt mount and tub/shower enclosure separately(Model#FV-VS43R),Fan can
fuse. when GFCI protected.Fan shall also be be used to comply with ASHRAE 62.2,
•Removable with permanently lubricated plug- ENERGY STARe certified,with a built-in speed LEED,EarthCraft,California Title-24 and WA
in motor, selector.Choose from 50-80-100 CFM and Ventilation Code.
no more than<0.3/0.4/0.9 sone as certified
Housing: by the Home Ventilating Institute(HVI)at 0.1 WhisperValue Contractor Pack*
•26 gauge galvanized steel body. static pressure in inches water gauge(w.g.) The Contractor Pack includes four complete
•Built-in 4'Oval duct collar.Also compatible with no less than 53/81/100 CFM and no fans.The housing and motor/grille are packaged
with 4°round duct. more than 0.5/0.8/1.3 sone as certified by HVI separately for flexibility during installation.
•Optional 24 gauge steel,fire code rated at 0.25 w.g.Power Consumption shall be no
4'oval to 3"round duct adaptor sold greater than 4.4/7.2/11.1 watts at 0.1 w.g.and Hnu sin Can1�lotur/Grille Complete Master
9 Assembly Fan Ilnit Prick
separately(Model#FV-VS43R). 7.5/11.5/16.0 watts at 0.25 w.g.,with efficiency
•Built in backdraft damper. of no less than 12.8/11.4/9.2 CFM/watt at 0.1 FV-0510VSA1 FV-0510VS81 FV-0510VS1 4
•Built-in metal flange provides blocking for w.g.and 7,9/7.2/6,4 CFM/watt at 0.25 w.g.The
penetrations through drywall as an Air Barrier, motor shall be totally enclosed with a brushless rasl "waneues°I 4 srywnent wa contain 1°°K with 4 wits
and assists with the decrease in leakage in the ECM motor engineered to run continuously.
Building Envelope during blower door testing. ECM motor speed shall automatically increase Performance Curve 4"Oval duct
•Unique L-shaped bracket simplifies installation when the fan senses static pressure to
and provides strong support. maintain selected CFM ower rating shall be ar _
070 .---
Specifications:WhisperValueDC FV-0510VS1 4"Oval 4"Oval 4"Oval � =m F
-,.i;- _.._ { i 4 was
Static Pressure in inches w.g. 0.1 ® 0.1 111 0.1 Ii 25 -+
Air Volume(CFM) 100 100 80 81 50 53 1 ��
Noise(sones) 0.9 1.3 0.4 0.8 <0.3 0.5 e i 'i-- ` J7/ i ,«o-m
Ventilation Fan Power Consumption(watts) 11.1 16.0 7.2 11.5 4.4 7,5 I . -1 •
r �
Characteristics _ t
Energy Efficiency(CFM/Watt) 9.2 6.4 11.4 7.2 12.8 7.9 43 I
(HVI Certified Speed(RPM) 902 1121 797 1070 708 1025 a^ l _" I__' ' *'''
J'
Data) Current(amps) 0.20 0.27 0.13 0.20 0.09 0.14 __.
MAX,Current(amps) 0.39
Power Rating(V/1-1z) 12W60
ENERGY STAR rated YES Airflow(CFM)
0.25=Instalied Performance
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date'
Panasonic Dco Solutions North America yt*�`T Foy,, ECM Motor Technology
Deo Products Division DC`rr When the fan senses static pressure,its speed is automatically Increased to ensure
Two RIverfront Plaza
Newark,NJ 07102 In, ,s3" that the desired CFM is not compromised,which allows the fan to perform as rated.
us.panasonic.com/ventfans
livii is
°®W Panasonic
VF155495S0517