Loading...
Permit (186) CITY OF TIGARD MASTER PERMIT 11_0._ q t, . , COMMUNITY DEVELOPMENT Permit#: MST2019-00182 TIGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/09/2019 Parcel: 2S103BB11400 Jurisdiction: Tigard Site address: 12145 SW 123RD CT Subdivision: YE-OLDE WINDMILL Lot: 33 Project: Webb Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $13,583.00 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Drywell-Trench Drain: 0 Other Fixtures: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar 4.41 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet: ALT SF VB R-3 0 Owner: Contractor: WEBB,THOMAS E AND JUDY A AURIC SOLAR LLC Required Items and Reports(Conditions) 12145 SW 123RD CT 9530 SW TUALATIN-SHERWOOD RD ' TIGARD,OR 97223 TUALATIN,OR 97062 PHONE: PHONE: 503-716-3055 FAX: Total Fees: $328.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will n formore the be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center Those rules are set forth in OAR :::;:th calling 4,..,_ ."4� Permittee Signature: / Call 503.639.4175 by 7:00 a.m.for the next available inspection date. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Building Permit Application , Residential FOR OFFICE t SE ONL\' Received Cityof Tigard Daante RBeyv:iew jj)- Permit No.r /7/1 »3i 13125 SW Hall Blvd.,Tigard,OR 97223 - Phone: 503.718.2439 Fax: 503.598.1960 ECEIVEftate/BY: ( n"J d- ! Other Permit: T t G n R D Inspection Line: 503.639.4175 Date Ready/By. Juris: ® See Page 2 for Internet: www.tigard-or.gov MAY 2 2019 .tified/Metho f # hi-a, Supplemental Information i x„�,,Eyy:y�.y�SrA%1h?83.rSE4t3EStYT4%.a9tEi'.RFh7vdt}^'tke?3:3rEEe e386#dEEEtk:6.n..rP.e emi xrE�'mF^.a3Ec:u9'��T"?6Ee...3..E?.�3 9 �'.,t`n.,......E.EE d..3:......"2,3E:7i?r....p XeEEEE1Mi6E#8e a ss'fiaEEC.fp";t.EEIEEPER��9%fi :6h'd�"Xt rpNgeap�XS�am aiv,rmep4yr�dvwrEFri?Eaa:EtiE a8e5E&ESs94°§EE626Yt,$fnetl6£b68666EdE8dK�NXSId.tt(dE r.....^EE:r ::6Ee6;�M.+EBN..k CS?E y t '•l,'�i�r� #'t i�C' �.,. ;641@ '��.� #' '� i .3• ❑New construction ❑Del IAPING DI Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all ❑Addition/alteration/replacement ®Other:Solar PV equipment,materials,labor,overhead,and the profit for the ttyit work indicated on this application. 111180 111(I l + 4 i° l Int EE piliIngigatimi; ® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $13,583.00 0.2 ❑Accessory building ❑Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms: igarE16, r t 1, «e t p t y pp i' Irol ' Total number of floors: 4ttaJob site address:12145 SW 123rd Ct New dwelling area: square feet City/State/ZIP:Tigard,OR 97223 Garage/carport area: square feet Suite/bldg./apt.no.: I Project name: 177329 Webb Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet qi° t l 9: s r' I' Subdivision: Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all tAlhirio NA” �,: equipment,materials,labor,overhead,and the profit for the IlisimaNimimocApwetierfie,impriA1 t t : ^ t Fid0Alg a �6iiszr: 10 Al �E�i�yi€ r work•indicated on this application. 4.41 kW Solar PV Array Valuation: $ Existing building area: square feet New building area: square feet &)6 t x, t tii lEx�. Number of stories: Name:Tom Webb Type of construction: Address:12145 SW 123`d Ct Occupancy groups: City/State/ZIP:Tigard,OR 97223 Existing: Phone:(503)740-3462 Fax:( ) New: 1°a u mt 3'eS jjet u rz i i li& m .•`i1779 tpt 41 41 Business name:Annie Energy LLC Structural plan review fee(or deposit): Contact name:Rob Smith FLS plan review fee(if applicable): Address:95.30 SW Tualatin-Sherwood Rd City/State/ZIP:Tualatin,OR Total fees due upon application: Phone:(570)592-8581 I Fax: :( ) Amount received: trA E-mail:rob.smith@auricenergy.com t t 4 fsoojmemnaimnmtopi € lE Commercial and residential prescriptive installation of t 4 t `' roof-top mounted Photo Voltaic Solar Panel System. Business name:Auric Energy Submit two(2)sets of roof plan with connection details and fire department access,along with the 2010 Oregon Address:9530 SW Tualatin-Sherwood Rd Solar Installation Specialty Code checklist. City/State/ZIP:Tualatin,OR 97062 Permit Fee(includes plan review $180.00 and administrative fees): Phone:(570)592-8581 Fax:( ) I State surcharge(12%of permit fee): $21.60 CCB lie.:212831 Total fee due upon application: $201.60 Authorized signature: .04 ` This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name:Rob Smith Date:5/1/19 *Fee methodology set by Tri-County Building Industry _ Service Board I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(ll/02/COM/WEB) building Permit Application Checklist , One- and Two-Family Dwelling FOR OFFICE USE oNL\ Cityof Tigard Received - ll DateBy: Permit No.: e 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits: Phone: 503.718.2439 Fax: 503.598.1960 T I Ci A R D• 24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical Internet: www.tigard-or.gov ❑ Other: THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW 1 es No NIA 1 Land use actions completed. See jurisdiction criteria for concurrent reviews. 0 0 0 2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. 0 0 0 3 Verification of approved plat/lot. 0 0 0 4 Fire district approval required. Name of district: 0 0 0 5 Septic system permit or authorization for remodel. Existing system capacity ❑ 0 0 6 Sewer permit. 0 0 0 7 Water district approval. 0 0 0 8 Soils report. Must carry original applicable stamp and signature on file or with application. ❑ ❑ 0 9 Erosion control 0 plan 0 permit required. Include drainage-way protection,silt fence design and location of catch- 0 0 0 basin protection,etc. 10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state 0 0 0 building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if copyright violations exist. 11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 0 0 there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and surface drainage. 12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size 0 0 0 and location. 13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, 0 0 0 furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc. 14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- 0 0 0 floor,wall construction,roof construction. More than one cross section may be required to clearly portray construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings and foundation,stairs,fireplace construction,thermal insulation,etc. 15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 0 0 Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope. Full-size sheet addendums showing foundation elevations with cross references are acceptable. 16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- 0 0 0 prescriptive path analysis provide specifications and calculations to engineering standards. 17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing 0 0 0 locations. Show attic ventilation. 18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 0 ❑ systems,see item 22,"Engineer's calculations." 19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists ❑ ❑ ❑ over 10 feet long and/or any beam/joist carrying a non-uniform load. 20 Manufactured floor/roof truss design details. ❑ ❑ ❑ 21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑ for four or more appliances. 22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑ architect licensed in Oreton and shall be shown to be a''licable to the 'ro'ect under review. JURISDICTIONAL SPECIFICS 23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ ❑ 24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑ 25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ 0 ❑ 26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. ❑ ❑ ❑ 27 "Drawn to scale"indicates standard architect or engineer scale. 0 0 ❑ 28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ ❑ ❑ Street Tree List. 29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑ and protection measures must be drawn to scale and must include the project arborist's signature of approval. 30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, ❑ ❑ ❑ including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings on a lot of record approved prior to September 9, 1995. L•\Building\Permits\SUP-RESPermitAppAoc 02/24/2011 440-4613T(11/02/COM/WEB) • Electrical Permit Application roil orr►CI: Irsi:ONLY /r Received IN it City of Tigard I\V/!�' ate/B Permit#: 13125 SW Hall Blvd.,Tigard,OR 97E CCG LLL�.�� PlDan Review Phone: 503.718.2439 Fax: 503.598.1960 ry Date/B : Related Permit#: Inspection Line: 503.639.4175 MAY 2 L0Ready Date/By: Suns: 10 See Page 2 for T I G A R I) Internet: www.tigard-or.gov Notified/Method: gs Supplemental Information <._... . , ...•, .;.. ,., ,,.. 4f,.m5�8 ❑New construction ❑Addition/alter c I tr!� -n • _ Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. ❑Demolition ®Other:Solar PV Array where the available fault current ❑Marinas and boatyards. EIIATMTEMRIIMBEEIREIEZIIVITVZRETIZIISEAE faitiLp`:.l'? exceeds 10,000 amps at 150 volts or ❑Floating buildings. ® 1-and 2-family dwelling ❑Commercial/industrial ElAccessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. ❑Multi-family ❑Master builder ®Other:Solar PV ❑Fire pump. 0 Installation of 150 KVA or WASSIMP:'iiiiteMZEZZIMNEZEZZEMEM.SPIEMIR ❑Emergency system. larger sepazately derived ❑Addition of new motor load of system. Job#: 177329 Job site address: 12145 SW 123rd Ct 100HP or more. ❑"A","E","1-z","1-3", City/State/ZIP:Tigard,OR 97223 ❑Six or more residential units. occupancy. ❑Health-care facilities. ❑Recreational vehicle parks. Suite/bldg./apt.#: I Project name:Urmil Bhatt ❑Hazardous locations. ❑Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions to job site: sE ilinanntaalregaiNEHM Description Qty. Each Total New residential single-or multi-family dwelling unit. Subdivision: I Lot#: Includes attached garage. 1,000 sq.ft.or less 168.54 4 Tax map/parcel 4: Ea.add'l 500 sq.ft.or portion 33.92 1 x* !eaae; � s� ,., is; t ' i k 4 t. 4 > ;'11314 Limited energy,residential 4.41 kW Rooftop Solar PV Installation (with above sq.ft.) 75.00 2 Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable e $ u ' �7 ]ll;€iE s . Services or Eedregrys installation, ® SteonPagd 2 /or relocation Name:Tom Webb 200 amps or less 100.70 2 Address: 12145 SW 123rd Ct 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP:Tigard,OR 97223 601 amps to 1,000 amps 301.04 2 Phone:(503)740-3462 I Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 . i Branch circuits new,alteration,or extension, er panel I JFK ' p (� ° A.Fee for branch circuits with Business name:Annie Solar LLC above service or feeder fee, 7.42 2 each branch circuit Contact name:Rob Smith B.Fee for branch circuits without Address:9530 SW Tualatin-Sherwood Rdservice or feeder fee,first 56.18 2 branch circuit City/State/ZIP:Tualtain,OR 97062 Each add'1 branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:(570)592-8581 Fax: :( ) Each manufactured or modular dwelling,service and or feeder 67.84 2 Email:rob.smith@auricenergy.com Reconnect only 67.84 2 �A l :.xi .al. :„.... Oa �I Pump or irrigation circle 67.84 2 Business name:Auric Solar LLC Sign or outline lighting 67.84 2 Address:2310 S 1300 W Signal panel,alteration,or extension. Elt(s)or limited-energy See Page 2 2 City/State/ZIP:Salt Lake City,UT Each additional inspection over allowable in any of the above Additional inspection(1 hr min) 66.25/hr Phone:(971)803-1803 Fax:( ) Investigation(1 hr min) 90.00/hr Email:rob.smith@auricenergy.com Industrial plant(1 hr min) 78.18/hr Inspections for which no fee is 90.00/hr CCB Lie.: 212831 Electrical Lic.: C1243 Suprv.Lic.: 6122S s.ecificall listed ''/hr min Suprv.Electrician signature,required: L_J �4 -j Subtotal: 133.56 Print name: Thaniel Bisho r I Date: 4/30/2019 ❑Plan Review Required(25%of permit fee): State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Rob Smith Date: 5/1/2019 days atter it has been accepted as complete. * Number of inspections allowed per permit. I:\Building\Permits\ELC PermitApp_EI.R ERE.doc Rev 06/17/2015 440-4615T(11/05/COMWEII • Electrical Permit Application—City of Tigard Page 2—Supplemental Information Limited Energy Permit Fees: Renewable Energy Permit Fees: n..i I , i 1 Fee for all residential systems combined: $75.00 Renewable electrical energy systems: IICheck Type of Work Involved: 5 kva or less 100.70 100 70 5.01 to 15 kva 133.56 _© ❑ Audio and Stereo Systems* 15.01 to 25 kva 1111 200.34 _© Wind •eneration s stems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 �© 50.01 to 100 kva 552.26 _© ❑ Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040 ■ 552.26 —© ❑ Heating,Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 11111 7.42 _© ❑ Vacuum Systems* >100 kva—no additional charge 0.0 _© Each additional ins I ection over allowable in an of the above: ❑ Other: Each additional inspection is ■ 66.25/hr char:ed at an hourl 1 hr min Inspections for which no fee is ■ 90.00/hr _. s�ecificall listed '/z hr min '�I: s L•Iir. �! '. _ . �, � iia 0 8r1 :E '�` Subtotal(Enter on Page 1) 133 56 Fee for each commercial system: $75.00 (SEE OAR 918-309-0000) ' Number of inspections allowed per permit. Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls ❑ Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations I:\Building\Permits\ELC_PemutApp_ELR ERE doe Rev 06/17/2015 City of Tigard IIII Building Division • • 13125 SW Hall Blvd, Tigard, OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 C C TIGARD Inspection Line: 503.639.4175 MAY 0 2 www.tigard-or.gov 2019 CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 12145 SW 123rd Ct City: Tigard Zip: 97223 Owner's Name: Tom Webb Date: 5/2/2019 Contractor's Name: Auric Solar LLC CCB #: 212831 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation 111 Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? ® No OSSC or ORSC for design requirements. Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes ® Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? If"Yes", qualifies for structures other than ® Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/PhotoVoltaic-Checklist.docx Is the construction material wood and does ® Yes Type of If"Yes", qualifies for the construction qualify Constructionas "conventional light ❑ No the prescriptive path. frame"construction? Is the spacing 24 inches or less? Pre-engineered trusses. -1 Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Is the combined weight ® Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation layout in accordance ® Yes with Section 305.4(3) of If"Yes", qualifies for 111the 2010 Oregon Solar No the prescriptive path. Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ® of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. ❑ of composition shingle. Is the roof mounted ® Yes Connections of solar assembly If"Yes", qualifies for the solar assembly connected to roof ❑ No to the roof framing or blocking the prescriptive path. directly? 2 I:Building/Forms/PhotoVoltaic-Checklist.docx • Is the gauge 26 or less? 111 Yes If"Yes", qualifies for ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directly to inches Maximum 60 inches inches, qualifies for the prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of If"Yes", qualifies for fastener? ❑ Yes the prescriptive path. ❑ No Is the roof decking of WSP min. 1/2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for solar modules module to the roof ® Yes the prescriptive path. surface. ❑ No 3 I:Building/Forms/PhotoVoltaic-Checklist.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: REC Model Number: 315NP 315W Modules Listing Agency: UL 1703 III 4 I:Building/Forms/PhotoVoltaic-Checklist.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 12145 SW 123RD CT, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2019-00182 Inspection Type: Inspector: 299 Final inspection David Young Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor City of Tigard Tel: 503.718.2439 Location: Inspection Date: 12145 SW 123RD CT, TIGARD, OR, 97223 Record Type: Record ID: Residential - Master Permit MST2019-00182 Inspection Type: Inspector: 199 Electrical final David Young Result: PASS Comments: Violation Summary: Inspector Contractor