Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Permit (180)
CITY OF TIGARD MASTER PERMIT 1 ' ' COMMUNITY DEVELOPMENT Permit#: MST2019-00172 T 1 C.A R.I) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/09/2019 Parcel: 2S 111 BA04000 Jurisdiction: Tigard Site address: 14100 SW 98TH CT Subdivision: MCDONALD ACRES Lot: 15 Project: KANDRA Project Description: Solar photovoltaic system. BUILDING Floor Areas Required Setbacks Required Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0 Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke Dwelling Units: 0 Third: 0 sf Right: 0 Detectors: Total: 0 sf Value: $9,185.94 Rear: 0 PLUMBING Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0 Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0 Drains: 0 Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Catch Basins: 0 Bckflw Prevntr: 0 Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0 Other Fixtures: 0 Drywell-Trench Drain: 0 Other Fixture Units: MECHANICAL Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0 Heat Pump: N Hoods: 0 Other Units: 0 Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0 Furn>=100K: 0 ELECTRICAL Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits 1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0 Ea add'I 500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0 Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0 601-1000 amp: 0 601+amp-1000v: 0 1000+amp/volt: 0 ELECTRICAL-RESTRICTED ENERGY SF Residential Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All Other: Y Other Description: Roof Top Solar PV 3.9 kW Ecompasing: N BUILDING INFO Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet ALT SF VB R-3 0 Owner: Contractor: KANDRA,CURTIS C&TRINA N BLUE RAVEN SOLAR LLC Required Items and Reports(Conditions) 14100 SW 98TH CT 1220 S 830 EAST,STE 430 TIGARD,OR 97224 AMERICAN FORK,UT 84003 PHONE: PHONE: 385-498-4408 FAX: Total Fees: $321.38 This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a cop of the rules or direct questions to OUNC by calling 503.232.1•:7 or 1.800.332.2344. Issued By: /y iAI.�,L.L/...•ice✓ Permittee Signature: /040:4 Call 503.839.4175 by 7:00 a.m.for the next available inspection date.Ilr This permit card shall be kept in a conspicuous place on the job site until completion of the prof Approved plans are required on the job site at the time of each inspection. Building Permit Application Itesidential FOR OFFICE USE ONLY • - City of Tigard Received �E C E I j C Date/By: . ��j�-- Permeit No.: 13125 S W Hall Blvd.,Tigard OR 97223 c C V G "" � � t Date/B view �� Phone: 503.718.2439 Fax: 503.598.1960 DateBy: Other Permit: T I t A K D Inspection Line: 503.639.4175 A p R 3 0 2019 Date ReadyBy: suds: ® See Page 2 for Internet: www.tigard-or.gov .rtitled/Method �� Y-T I Supplemental Information " Frio a ^ 4 R" .`1 t ° ,.ata " a + i a -. fi t;. -, - d�'+d c ! r al j`t"" 0 New construction 0 Demolition Permit fees*are based on the value of the work performed. Indicate the value(rounded to the nearest dollar)of all 0 Addition/alteration/replacement ❑Other equipment,materials,labor,overhead,and the profit for the N to AFF : lx work indicated on this application. 0 1-and 2-family dwelling 0 Commercial/industrial Valuation: $ 9185.94 ❑Accessory building ❑Multi-family Number of bedrooms: 0 Master builder 0 Other: Number of bathrooms: IVIENIBISBJOBS 1 ® ' ' y A t Total number of floors: Job site address: 14100 Southwest 98th Court, Tigard,Oregon, 97224, United States New dwelling area: square feet City/State/ZIP: Garage/carport area: square feet Suite/bldg./apt.no.: Project name: Curt Kandra Covered porch area: square feet Cross street/directions to job site: Deck area: square feet Other structure area: square feet 1 1 DDT t Subdivision: I Lot no.: Permit fees*are based on the value of the work performed. Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all equipment,materials,labor,overhead,and the profit for the . ?.. l ' ...,., r, work indicated on this application. Rooftop Solar PV Valuation: $ 3,O l,L*) Existing building area: square feet New building area: square feet :.0 ^r : _ : f_. ! t . as1rµ auy _3v « ra :: __ It_1y_«r 1 Number of stories: Name: Curt Kandra Type of construction: Address:14100 Southwest 98th Court,Tigard,Oregon,97224,United States Occupancy groups: City/State/ZIP: Existing: Phone ( ) Fax ( ) New: M Business name:Blue Raven Solar .•..•.•_-._: :_==sk===-•.;: ,• :,.:7"iiiiiiiiiiiiiiiiiiiiiiinorAig Contact name: Lesly Bee Structural plan review fee(or deposit): Address: 220 S 630E FLS plan review fee(if applicable): City/State/ZIP: American Fork UT, 84003 Total fees due upon application: Phone:(385)482-0045 Fax::( ) Amount received: E-mail: permitting.deparment@blueravensolar.com 't or TAlCS M x: r r Ytia ' .t ,: Commercial and residential prescriptive installation of .,....v� ...,,..,. ,v.! .. 1 roof-top mounted Photo Voltaic Solar Panel System. .. a,,,,,, ,,,,,,,__.,, .•=r..W,.�.�.:ui.w;.x�a»,-c3:ni..,,+ Ft�:t:e;;v t._.•.,,I'�`jl�". Business name: Blue Raven Solar Submit two(2)sets of roof plan with connection details Address: 1220 S 630E and fire department access,along with the 2010 Oregon Solar Installation Specialty Code checklist. City/State/ZIP: American Fork UT, 84003 Permit Fee(includes plan review $180.00 Phone:(3853482-0045 Fax:( ) and administrative fees): 210112 State surcharge(12%of permit fee): $21.60 CCB lic.: Total fee due upon application: $201.60 Authorized signature: 4?4 This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Print name: Jeffrey Lee Date: 04/26/2019 *Fee methodology set by Tri-County Building Industry S-rvi - :a, I I:\Building\Permits\BUP-RESPermitApp.doe 02/24/2011 440-4613T(11/02/COM/WEB) 1 Electrical Permit Application FOR OFFICE ('SF.ONLY ' City of Tigard Received g DateB : Permit#: 4, " " 13125 SW Hall Blvd.,Tigard,OR 97223 I Plan Review 77 Phone: 503.718.2439 Fax: 503.598.1960 Date/B : Related Permit#: T I G A R D Inspection Line: 503.639.4175 Ready Date/By: Juris: ® See Page 2 for Internet: www.tigard-or.gov Notified/Method: Supplemental Information monstimagsmomiumml,WACWORKIMENCENRIZERMINERITIRM ZRIESEREMEZEKOMCREVISVHEREIMEMBEEME ❑New construction ©Addition/alteration/replacement Please check all that apply(submit 2 sets of plans w/items checked): ❑Service or feeder 400 amps or more ❑Building over three stories. 0 Demolition 0 Other: where_..,. •, 8, .O' L.:11 '� 1 exceeds 10,000 e available mps at 150 current 150 volts or ElFlMarinas ng buildings.ards. ©1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 ❑Commercial-use agricultural amps for all other installations. buildings. 0 Multi family 0 Master builder , Other 0 ❑Fire pump. 0 Installation of 150 KVA or millillinsuoginiMem*istwi7'iia:77tWANDI!!: :b:WilliMIIITIMBERIONME 0 Emergency system. larger separately derived 14100 Southwest 98th Court, Tigard, ❑Addition of new motor load of system. Job#: Job site address: 100HP or more. ❑"A","E","1-2","1-3", ❑Six or more residential units. occupancy. City/State/ZIP: ❑Recreational vehicle ar ❑Health-care facilities. P �• Suite/bldg./apt.#: I Project name: Curt Kandra ❑Hazardous locations. 0 Supply voltage for more than ❑Service or feeder 600 amps or more. 600 volts nominal. Cross street/directions : :::::: :.:: :;:::::>:;:::::::: :::::::::::::;: to job site: _ €€it<iiii€si`iis ii;;:i=`;i€ifi=.�viii:=i€€n =€ii?�;:°,,.._ :::::-:::.:..: :....:....::.::::::::::::::�:::::�:::,:: -::::::::::::::�:::::::�::: Description I Qty. I Each I Total I New residential single-or multi-family dwelling unit. Subdivision: Lot#: Includes attached garage. Tax map/parcel#: 1,000 sq.ft.or less 168.54 4 Ea.add l 500 sq.ft.or portion 33.92 1 ..,.,,.. l �...... ! Limited energy,residential 75.00 2 Rooftop Solar PV (with above sq.ft.) Limited energy,multi-family 75.00 2 residential(with above sq.ft.) Renewable Energy ❑ See Page 2 `" """' ""'i -- --,-: - --" - U T :::• _ Services or feeders installation,alteration,and/or relocation Name: Curt Kandra 200 amps or less 100.70' 2 Address: 14100 Southwest 98th Court,Tigard, Oregon,97224, United States 201 amps to 400 amps 133.56 2 401 amps to 600 amps 200.34 2 City/State/ZIP: 601 amps to 1,000 amps 301.04 2 Phone:( ) I Fax:( ) Over 1,000 amps or volts 552.26 2 Temporary services or feeders installation,alteration,and/or Email: relocation Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1 intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2 Owner signature: Date: 401 amps to 599 amps 168.54 2 4i 1 U `AC"`` T ! Branch circuits—new,alteration,or extension,per panel A Fee for branch circuits with Business name: Blue Raven Solar above service or feeder fee, 7.42 2 each branch circuit Contact name: Lesly Bee B.Fee for branch circuits without Address: 1220 S 630E service or feeder fee,first branch circuit 56.18 2 City/State/ZIP: American Fork, UT 84003 Each add'l branch circuit 7.42 2 Miscellaneous(service or feeder not included) Phone:( 385)482-0045 Fax: :( ) Each manufactured or modular dwelling,service and/or feeder 67.84 2 Email: permitting.department@blueravensolar.com Reconnect only 67.84 2 w_ . . r , .... _ _. . ,..... ., Pump or irrigation circle 67.84 2 Business name: Blue Raven Solar Sign or outline lighting 67.84 2 Address: 1220 S 630E Signal circuit(s)or limited-energy 0 See Page 2 2 panel,alteration,or extension. Each additional inspection over allowable in any of the above City/State/ZIP: American Fork, UT 84003 Additional inspection(1 hr min) 66.25/hr Phone:385 482-0045 Fax:( ) Investigation(1 hr min) 90.00/hr Email: permitting.department@blueravensolar.com Industrialplant(1 hrmn) 78.18/hr 6 / �+ /ph i Inspections for which no fee is CCB Lic.:210112 Electrical Lic.: C1214 Suprv.Lic.: .6061-7-8— specifically listed('/*hr mm) 90'00,12,1:, Suprv.Electrician signature,required: s"'<.�e� Subtotal: Print name: Sam Collier Date: 04/26/2019 ❑Plan Review Required(25%of permit fee): �� � State surcharge(12%of permit fee): Authorized signature: TOTAL PERMIT FEE: This permit application expires if a permit is not obtained within 180 Print name: Jeff Lee Date: 04/26/2019 days after it has been accepted as complete. ' Number of inspections allowed per permit. C\Building\Permits\ELC_PennitApp_ELR_ERE.doc Rev 06/17/2015 440-4615T(11/05/COM/WEB Electrical Permit Application—City of Tigard Page 2-Snpplemental Information . , Limited Energy Permit Fees: Renewable Energy Permit Fees: . ........ .......... ......... ....:.., : ';#111511•1191•11S1 Description I QtY I Each I Total I � Fee for all residential systems combined: $75.00 Renewable electrical energy systems: Check Type of Work Involved: 5 kva or less 100.70 2 5.01 to 15 kva 133.56 2 ❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2 Wind generation systems in excess of 25 kva: ❑ Burglar Alarm 25.01 to 50 kva 301.04 2 50.01 to 100 kva 552.26 2 Garage Door Opener* >100 kva(fee in accordance with OAR 918-309-0040) 552.26 2 ❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva: System* Each additional kva over 25 7.42 3 ❑ Vacuum Systems* >100 kva-no additional charge 0.0 3 Each additional inspection over allowable in any of the above: EN Other: Solar PV System Each additional inspection is 66.25/hr 1 charged at an hourly(1 hr min) Inspections for which no fee is 90.00/hr specifically listed(V2 hr min) Fee for each commercial system: $75.00 Subtotal(EnterPage 1): * Number of inspections allowed perrperm permit.t. (SEE OAR 918-309-0000) Check Type of Work Involved: ❑ Audio and Stereo Systems ❑ Boiler Controls ❑ Clock Systems ❑ Data Telecommunication Installation ❑ Fire Alarm Installation ❑ HVAC ❑ Instrumentation ❑ Intercom and Paging Systems ❑ Landscape Irrigation Control* ❑ Medical ❑ Nurse Calls n Outdoor Landscape Lighting* ❑ Protective Signaling ❑ Other: Total number of commercial systems: *No licenses are required. Licenses are required for all other installations 1:\Building\Permits\ELC_PennitApp_ELR_ERE.doc Rev 06/17/2015 City of Tigard Building Division • 13125 SW Hall Blvd, Tigard, OR 97223 RECEIVED Phone: 503.718.2439 Fax: 503.598.1960 TIGARD Inspection Line: 503.639.4175 APR 3 0 2019 www.tigard-or.gov CITY OF TIGARD BUILDING DIVISION 2010 Oregon Solar Installation Specialty Code Check List for Prescriptive Installation of Roof-Mounted PhotoVoltaic Solar Panel System Property Information Installation Address: 14100 Southwest 98th Court, Tigard, Oregon, 97224, United City: Zip: Owner's Name: Curt Kandra Date: 04/26/2019 Contractor's Name: Blue Raven Solar CCB #: 210112 Design Parameters of the Property/Structure If"Yes", does not Flood Hazard Is the installation 111 Yes qualify for the Area Located in a flood prescriptive path, follow plain/flood way? p No OSSC or ORSC for design requirements. Is the windexposure Yes Wind ExposureIf"Yes", qualifies for "C" or less? ❑ No the prescriptive path. Installations on detached Is the Ground Snow single/two-family Load 70 psf or less? dwelling/single/two- If"Yes", qualifies for family townhomes © Yes the prescriptive path. and/or their accessory Ground structures. ❑ No Snow Load Is the Ground Snow Installations on all Load 50 psf or less? structures other than If"Yes", qualifies for Yes the prescriptive path. above ❑ No 1 I:/Building/Forms/Photovoltaic-Checklist02-01-I I.docx Is the construction CI Yes Type of material wood and does Yp If"Yes", qualifies for the construction qualify Construction as "conventional light 111No the prescriptive path. frame" construction? Is the spacing 24 inches or less? Pre-engineered trusses. D Yes If"Yes", qualifies for the prescriptive path. ❑ No Roof framing members Is the spacing 24 inches or less? Nominal lumber. If"Yes", qualifies for Yes the prescriptive path. ❑ No Is the combined weight p Yes of the PV modules and If"Yes", qualifies for racking less than or ❑ No the prescriptive path. Solar equal to 4.5 psf? installation Is the solar installation Ci layout in accordance Yes with Section 305.4(3) of If"Yes", qualifies for ❑ No the prescriptive path. the 2010 Oregon Solar Code? ❑ Metal Single layer If roofing material is Roofing Check the type of ❑ of wood one of the three types material roofing material shingle/shake checked, qualifies for Max. two layers the prescriptive path. In of composition shingle. Is the roof mounted p Yes Connections of solar assembly the solar assembly connected to roof If"Yes", qualifies for ElNo the prescriptive path. to the roof framing or blocking directly? 2 I:/Building/Forms/PhotoVoltaic-Checklist02-01-11.docx ❑ Yes If"Yes", qualifies for Is the gauge 26 or less? ❑ No the prescriptive path. 115 lbs for 60 inch spacing or less? ❑ If"Yes", qualifies for Yes the prescriptive path. ❑ No Minimum Uplift rating of Clamps? 75 lbs for 48 inches spacing or less? If"Yes", qualifies for ❑ Yes the prescriptive path. ❑ No Attachment of roof mounted Minimum 24 inches If the spacing falls solar systems Spacing of clamps? within 24 inches and 60 directl to inches inches, qualifies for the Y Maximum 60 inches prescriptive path. standing seam metal panels Width of roofing If the width of the panel panels? 18 inches or less is less than 18 inches, inches qualifies for the prescriptive path. Minimum#10 at 24 inches o/c? Size and spacing of Yes If"Yes", qualifies for fastener? ❑ the prescriptive path. ❑ No Is the roof decking of WSP min. %2"thickness, ❑ Yes decking connected to If"Yes", qualifies for framing members ❑ No the prescriptive path. w/min. 8d nails @ 6"/12" o/c? Is the height less than or Maximum 18 inches equal to 18 inches? Height of the from the top of the If"Yes", qualifies for MI solar modules module to the roof Yes the prescriptive path. surface. ❑ No 3 I:/Building/Forms/PhotoVoltaic-Checklist02-0 1-1 1.docx Submittal Documents required for Prescriptive Installations Show the location of the PV system in relation to buildings, structures, property lines, and, as applicable, flood hazard areas. Site Plan Details must be clear and easy to read. Minimum size of the plan is 8.5 x 11 inches. Attach a simple structural plan showing the roof framing (rafter size, type, and spacing) and PV module system racking attachment. System must be shown in sufficient detail and clarity to assess whether it Structural Plan meets the prescriptive construction requirements as listed earlier above in the matrix. Minimum size of the plan is 8.5 x 11 inches. PV Modules Manufacturer: TrinaSolar Model Number: 13 Listing Agency: CSA 4 I:/Building/Forms/PhotoVoltaic-Checklist02-0 1-11.docx City of Tigard Tel: 503.718.2439 Location: Inspection Date: 14100 SW 98TH CT, TIGARD, OR, 97224 June 4, 2019 at 8:56:13 AM Record Type: Record ID: Residential - Master Permit MST2019-00172 Inspection Type: Inspector: 199 Electrical final Jeremy Burrows Result: PASS Comments: Violation Summary: Inspector Contractor City of Tigard Tel: 503.718.2439 Location: Inspection Date: 14100 SW 98TH CT, TIGARD, OR, 97224 June 4, 2019 at 8:56:16 AM Record Type: Record ID: Residential - Master Permit MST2019-00172 Inspection Type: Inspector: 299 Final inspection Jeremy Burrows Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor