Report (35) - 2o'ij 30Z),1 sw £Y SYSTEM RECORD OF COMPLETION This form is to be completed by the system Installation contractor at the time of system acceptance and approval. It shall be permitted to modity this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines Attach additional sheets,data,or calculations as necessary to provide a complete record. Form Completion Date: 5/9/19 Supplemental Pages Attached: 1 1. PROPERTY INFORMATION Name of property: Triangle Corporate Park III-Centene Address: 13221 SW 68th Pkwy Suite 300 Tigard,OR 97223 Description of property: Suite 300-Tenant Improvement Name of property representative: CBRE Address: 13221 SW 68th Pkwy Tigard,OR 97223 Phone: 503-701-8953 Fax: E-mail: 2. INSTALLATION,SERVICE,TESTING,AND MONITORING INFORMATION Installation contractor: PROTEK SYSTEMS,LLC Address: 305 SE Chkalov Drive Suite 111#361 Vancouver,WA 98683 Phone: (360)314-2017 Fax: E-mail: admin@protek.systems Service organization: PROTEK SYSTEMS,LLC Address: 305 SE Chkalov Drive Suite 111#361 Phone: (360)314-2017 Fax: E-mail: admin@protek.systems Testing organization: PROTEK SYSTEMS,LLC Address: 305 SE Chkalov Drive Suite 111#361 Phone: (360)314-2017 Fax: E-mail: admin@protek.systems Effective date for test and inspection contract: 12/5/18 Monitoring organization: Central Station Monitoring Address: Phone: Fax: E-mail: Account number: Phone line 1: Phone line 2: Means of transmission: Entity to which alarms are retransmitted: N/A Phone: N/A 3. DOCUMENTATION On-site location of the required record documents and site-specific software: 1st Floor-FACP 4. DESCRIPTION OF SYSTEM OR SERVICE This is a: LI New system Sl Modification to existing system Permit number: FPS2019-00048 NFPA 72 edition: 2013 4.1 Control Unit Manufacturer: EST Model number: 2 4.2 Software and Firmware Firmware revision number: N/A 4.3 Alarm Verification 11 This system does not incorporate alarm verification. Number of devices subject to alarm verification: Alarm verification set for seconds 02012 National Fire Protection Association NFPA 72(p.1 of 3) 2013 Edition # • SYSTEM RECORD OF COMPLETION (continued) 5. SYSTEM POWER 5.1 Control Unit 5.1.1 Primary Power Input voltage of control panel: 120VAC Control panel amps: 3.6A Overcurrent protection: Type: Breaker Amps; 20A Branch circuit disconnecting means location: House Panel Number: 5.1.2 Secondary Power Type of secondary power: Batteries-12VDC 7AH Location,if remote from the plant: Calculated capacity of secondary power to drive the system: In standby mode(hours): 24 In alarm mode(minutes): 5 5.2 Control Unit ❑ This system dries not have power extender panels 5i Power extender panels are listed on supplementary sheet A 6. CIRCUITS AND PATHWAYS Dual Media Separate Survivability Pathway Type Pathway Pathway Class Level Signaling Line X B 0 Device Power Initiating Device Notification Appliance X B 0 Other(specify): 7. REMOTE ANNUNCIATORS Type Location S-BUS Lobby 8. INITIATING DEVICES Addressable or Alarm or Sensing Type Quantity Conventional Supervisory Technology Manual Pull Stations Existing Smoke Detectors Existing Duct Smoke Detectors Existing Heat Detectors Existing Gas Detectors N/A Waterflow Switches Existing Tamper Switches Existing 0 2012 Natbnal Fire Protection Association NFPA 72(p.2 o1 3) SYSTEM RECORD OF COMPLETION (continued) 9. NOTIFICATION APPLIANCES Type Quantity Description Audible Visible 2 Strobe Combination Audible and Visible 1 Horn Strobes 10. SYSTEM CONTROL FUNCTIONS Type Quantity Hold-Open Door Releasing Devices Existing HVAC Shutdown Existing Fire/Smoke Dampers Existing Door Unlocking Existing Elevator Recall Existing Elevator Shunt Trip Existing • • 11. INTERCONNECTED SYSTEMS This system does not have interconnected systems. Interconnected systems are listed on supplementary sheet 12. CERTIFICATION AND APPROVALS 12.1 System Installation Contractor This system as specified heroin has been installed according to all NFPA standards cited herein. Signed: 4 c5Gu2 Printed name: Adam Sweet Date: 5/9/19 Organization: PROTEK SYSTEMS,LLC Title: Fire Alarm Systems NICET III Phone: (253)448-1604 12.2 System Operational Test This system as specified herein has tested according to all NFPA standards cited herein. Signed: .Aedam 310444- Printed name: Adam Sweet Date: 5/9/19 Organization: PROTEK SYSTEMS,LLC Title: Fire Alarm Systems NICET III phone: (253)448-1604 12.3 Acceptance Test Date and time of acceptance test: 5/9/19 -6:00am installing contractor representative: Adam Sweet Testing contractor representative: Randy Geyman Property representative: AHJ representative: 0 2012 National Fire Protection Association NFPA 72(p.3 of 3) NOTIFICATION APPLIANCE POWER PANEL SUPPLEMENTARY RECORD OF COMPLETION This form is a supplement to the System Record of Completion.It includes a list of types and locations of notification appliance power extender panels. This form is to be completed by the system installation contractor at the time of system acceptance and approval. It shall be permitted to modify this form as needed to provide a more complete and/or clear record. Insert N/A in all unused lines. Form Completion Date: 5/9/19 Nirnber of Supplemental Pages Attached: 1 1. PROPERTY INFORMATION Name of property: Centene Address: 13221 SW 68th Pkwy 2. NOTIFICATION APPLIANCE POWER EXTENDER PANELS Make and Model Location Area Served Power Source Silent Knight 5495 3rd Floor Elec Rm 3rd Floor 120VAC See Main System Record of Completion for additional Information,certifications,and approvals. 0 2012 National Fire Protection Association NFPA 72