Project No: 1810
General Information and Design Criteria
Site Information:
Location= Tigard,OR
Site Latitude= 45.431229
Site Longitude= -122.771486
Ss= 0.972 g
S1= 0.423 g
Response Modification Factor,R= 6.5
System Overstrength Factor,W= 2.0
Deflection Amplification Factor,Cd= 4.0
Structure Geometry: Dead Loads:
Structure Heights: Roof:
Overall Structure Height= 33.00 ft Asphalt Shingles 3 psf
Mean Roof Height,h= 31.75 ft %"Plywood Sheathing 2 psf
Wood Roof Framing 5 psf
3rd Floor Wall Heights= 10.00 ft %"Gypsum Finishes 2.5 psf
3rd Floor Depth= 12.00 in Miscellaneous 2.5 psf
2nd Floor Wall Heights= 9.00 ft Roof Dead Load= 15 psf
2nd Floor Depth= 12.00 in
1st Floor Wall Heights= 8.00 ft Floors:
Foundation to 1st Floor Walls= 6.00 in Flooring(subfloor/carpet/tile) 5 psf
%"Plywood Sheathing 2.8 psf
Top of 3rd Floor Walls= 30.50 ft (Eave Height) %"Gypsum Finishes 2.5 psf
Top of 2nd Floor Walls= 21.00 ft Wood Floor Framing 2 psf
Top of 1st Floor Walls= 8.50 ft Lights and Mechanical 2 psf
Insulation 1.5 psf
Roof Slope: Miscellaneous 2.2 psf
Floor Dead Load= 18 psf
Roof Slope= 4 :12
Exterior Walls:
Plan Lengths and Areas: Horizontal Lap Siding 2 psf
Y:"Plywood Sheathing 2 psf
Max Length,L= 40 ft 2x6 Studs @ 16"oc 3 psf
Max Width,W= 24 ft 534"Insulation 2.75 psf
%"Gypsum Finishes 2.5 psf
ARoof= 1,085 ft2 Miscellaneous 0.75 psf
Aupper Floor= 953 ft2 Exterior Wall Dead Load= 13 psf
AMainFloor= 890 ft2
Partition Walls:
Perimeter of the Roof= 128 ft %"Gypsum Finishes 2.5 psf
Perimeter of the Floor= 128 ft 2x4 Studs @ 16"oc 2 psf
Perimeter of the Floor= 128 ft 334"Insulation 1.75 psf
%"Gypsum Finishes 2.5 psf
Lave Loads: Miscellaneous 0.25 psf
Roof= 25 psf Partition Wall Dead Load= 9 psf
Floor= 40 psf Structure Dead Load:
WRoof= 16,275 lb
W3rd Floor= 17,154 lb
Wzod Floor= 16,020 lb
Ward walls= 19,570 lb
Wznd was= 17,549 lb
Wistwalls= 15,715 lb
1/43
Lateral Design-Main Wind Force Resisting System-Method 1
*Note:Lateral Design performed according to the ASCE 7-10,IBC 2012 and 2012 International Transverse Longitudinal
Building Code ultimate design criteria as adopted by the OSSC P,30 P,XK,,IP,3o P,35 P,=XK:LIP,30
Location:Tigard,OR (psi) (psi) (psf) (psi)
Wind Velocity,V= 120 mph A 17.27 17.97 12.80 13.32
Exposure= B Cladding B -4.92 0.00 -6.70 0.00
Bldg Classification= II 24.1 C 11.52 11.99 8.50 8.84
Roof Type= Gable D -2.73 0.00 -4.00 0.00
Roof Height,hr= 33.00 feet E -15.40 -16.02 -15.40 -16.02
Eave Height,he= 30.50 feet F -10.51 -10.94 -8.80 -9.16
Building Width,W= 24 feet G -10.70 -11.13 -10.70 -11.13
Building Length,L= 40 feet H -7.97 -8.30 -6.80 -7.08
Roof Rise,y= 4
Roof Run,x= 12
Roof Angle,0= 18.4 '
Mean Roof Ht,h= 31.75 feet a=0.4*h 12.7
Adjustment Factor,I= 1.04 a=0.1*L 3
Importance Factor,I= 1.00 2a= 6
Topo.Factor,Kzt= 1
Transverse Direction (Controls)
3rd Floor Wall Heights= 10 ft
2nd Floor Wall Heights= 9 ft
1st Floor Wall Heights= 8 ft
Roof to 3rd Foor Trib Parapet
Wa= 17.97 psf 5 + 17.97 psf 2.5 135 plf
Wb= 11.99 psf 5 + 11.99 psf 2.5 90 plf
3rd to 2nd Floor
Wa= 17.97 psf 9.5 171 plf
Wb= 11.99 psf 9.5 114 plf
2nd to 1st Floor
Wa= 17.97 psf 8.5 153 plf
Wb= 11.99 psf 8.5 102 plf
2/43
1/8/2018 Design Maps Summary Report
tsGs Design Maps Summary Report
User-Specified Input
Building Code Reference Document ASCE 7-10 Standard
(which utilizes USGS hazard data available in 2008)
Site Coordinates 45.43123°N, 122.77149°W
Site Soil Classification Site Class D — "Stiff Soil"
Risk Category I/II/III
J-I®
l ori,
• ry
Gres
•
•
'I C
T1 r'i . _,
Lake C svvego
100
I tir
407 Sherwood
,x F
f 'Oregon City
USGS-Provided Output
SS = 0.972 g SMS = 1.080 g SDs = 0.720 g
S1 = 0.423 g SM1 = 0.667 g S01 = 0.445 g
For information on how the SS and Si values above have been calculated from probabilistic (risk-targeted) and
deterministic ground motions in the direction of maximum horizontal response, please return to the application and
select the"2009 NEHRP"building code reference document.
%$CE5 Response Spectrum Des Res se Spectrum
a �
an
0-77- .? ""r,
'.
a41 a.52
Ct35 - Ao-:z
i
cm ,m
•
Pef'sca.T(sec) Pence.T(sec)
For PGAM, T„ CRS, and CR, values, please view the detailed report.
Although this information is a product of the U.S.Geological Survey,we provide no warranty, expressed or implied, as to the
accuracy of the data contained therein.This tool is not a substitute for technical subject-matter knowledge.
3/43
https://earthquake.usgs.gov/cn2/designmaps/us/summary.php?template=minimal&latitude=45.431229&longitude=-122.771486&siteclass=3&riskcateg... 1/1
1/8/2018 Design Maps Detailed Report
ri(WS Design Maps Detailed Report
ASCE 7-10 Standard (45.43123°N, 122.77149°W)
Site Class D - "Stiff Soil", Risk Category I/II/III
Section 11.4.1 — Mapped Acceleration Parameters
Note: Ground motion values provided below are for the direction of maximum horizontal
spectral response acceleration. They have been converted from corresponding geometric
mean ground motions computed by the USGS by applying factors of 1.1 (to obtain Ss) and
1.3 (to obtain Si). Maps in the 2010 ASCE-7 Standard are provided for Site Class B.
Adjustments for other Site Classes are made, as needed, in Section 11.4.3.
From Figure 22-1 [1] Ss = 0.972 g
From Figure 22-2[23 S1 = 0.423 g
Section 11.4.2 — Site Class
The authority having jurisdiction (not the USGS), site-specific geotechnical data, and/or
the default has classified the site as Site Class D, based on the site soil properties in
accordance with Chapter 20.
Table 20.3-1 Site Classification
Site Class vs N or' ch s„
A. Hard Rock >5,000 ft/s N/A N/A
B. Rock 2,500 to 5,000 ft/s N/A N/A
C. Very dense soil and soft rock 1,200 to 2,500 ft/s >50 >2,000 psf
D. Stiff Soil 600 to 1,200 ft/s 15 to 50 1,000 to 2,000 psf
E. Soft clay soil <600 ft/s <15 <1,000 psf
Any profile with more than 10 ft of soil having the
characteristics:
• Plasticity index PI> 20,
• Moisture content w >_ 4O%, and
• Undrained shear strength s < 500 psf
F. Soils requiring site response See Section 20.3.1
analysis in accordance with Section
21.1
For SI: lft/s = 0.3048 m/s 11b/ft2 = 0.0479 kN/m2
4/43
https://earthquake.usgs.gov/cn2/designmaps/us/report.php?template=minimal&latitude=45.431229&longitude=-122.771486&siteclass=3&riskcategory... 1/6
1/8/2018 Design Maps Detailed Report
Section 11.4.3 - Site Coefficients and Risk-Targeted Maximum Considered Earthquake (MCEia)
Spectral Response Acceleration Parameters
Table 11.4-1: Site Coefficient Fa
Site Class Mapped MCE R Spectral Response Acceleration Parameter at Short Period
S550.25 S5 = 0.50 S5 = 0.75 S5 = 1.00 S5 >_ 1.25
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of SS
For Site Class = D and SS = 0.972 g, F. = 1.111
Table 11.4-2: Site Coefficient F,
Site Class Mapped MCE R Spectral Response Acceleration Parameter at 1-s Period
5, 5 0.10 S, = 0.20 S1 = 0.30 Si = 0.40 Si >_ 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.7 1.6 1.5 1.4 1.3
D 2.4 2.0 1.8 1.6 1.5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7 of ASCD-7
Note: Use straight-line interpolation for intermediate values of S,
For Site Class = D and Sl = 0.423 g, F„ = 1.577
5/43
https://earthquake.usgs.gov/cn2/designmaps/us/report.php?template=minimal&latitude=45.431229&longitude=-122.771486&siteclass=3&riskcategory... 2/6
1/8/2018 Design Maps Detailed Report
Equation (11.4-1): SMS = FaSs = 1.111 x 0.972 = 1.080 g
Equation (11.4-2): SM1 = F„S1 = 1.577 x 0.423 = 0.667 g
Section 11.4.4 — Design Spectral Acceleration Parameters
Equation (11.4-3): Sos = 2/3 SMS = 2/3 x 1.080 = 0.720 g
Equation (11.4-4): Sol = 2/3 SM1 = 2/3 x 0.667 = 0.445 g
Section 11.4.5 — Design Response Spectrum
From Figure 22-12 03 T, = 16 seconds
Figure 11.4-1: Design Response Spectrum
T<T3_S =S (0.4+0.6T/To)
T,sTST5:S.=Sm
TSaTSTL:Sa=SD,/T
T> :S =SEITL
9
{
,445
� a E
72
.r1
Pecos saw)
6/43
https://earthquake.usgs.gov/cn2/designmaps/us/report.php?template=minimal&latitude=45.431229&longitude=-122.771486&siteclass=38aiskcategory... 3/6
1/8/2018 Design Maps Detailed Report
Section 11.4.6 — Risk-Targeted Maximum Considered Earthquake (MCER) Response Spectrum •
The MCER Response Spectrum is determined by multiplying the design response spectrum above by
1.5.
V
U
V
y
� e
61 g 11,01.
Penod.r;secs
7/43
https://ea rthg uake.usgs.goy/cn2/desig n ma ps/us/repo rt.php?template=mini mal&latitude=45.431229&longitud e=-122.771486&s iteclass=3&riskcategory... 4/6
1/8/2018 Design Maps Detailed Report
• Section 11.8.3 - Additional Geotechnical Investigation Report Requirements for Seismic Design
Categories D through F
From Figure 22-7[4] PGA = 0.425
Equation (11.8-1): PGA,, = FPGAPGA = 1.075 x 0.425 = 0.457 g
Table 11.8-1: Site Coefficient FPGA
Site Mapped MCE Geometric Mean Peak Ground Acceleration, PGA
Class
PGA <_ PGA = PGA = PGA = PGA >_
0.10 0.20 0.30 0.40 0.50
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7 of ASCE 7
Note: Use straight-line interpolation for intermediate values of PGA
For Site Class = D and PGA = 0.425 g, FPGA = 1.075
Section 21.2.1.1 - Method 1 (from Chapter 21 - Site-Specific Ground Motion Procedures for
Seismic Design)
From Figure 22-17[5] CRS = 0.897
From Figure 22-18[63 CRl = 0.871
8/43
https://earthquake.usgs.gov/cn2/desig nmaps/us/report.php?template=minimal&latitude=45.431229&longitude=-122.771486&siteclass=3&riskcategory... 5/6
1/8/2018 Design Maps Detailed Report
Section 11.6 — Seismic Design Category •
Table 11.6-1 Seismic Design Category Based on Short Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF SOS
I or II III IV
Sps < 0.167g A A A
0.167g <_ Sos < 0.33g B B C
0.33g <_ SDs < 0.50g C C D
0.50g5Sps D D D
For Risk Category = I and Sps = 0.720 g, Seismic Design Category = D
Table 11.6-2 Seismic Design Category Based on 1-S Period Response Acceleration Parameter
RISK CATEGORY
VALUE OF SD1
I or II III IV
Spl < 0.067g A A A
0.067g 5 Spl < 0.133g B B C
0.1339 <_ SD, < 0.20g C C D
0.20g <_ S01 D D D
For Risk Category = I and S01 = 0.445 g, Seismic Design Category = D
Note: When Si is greater than or equal to 0.75g, the Seismic Design Category is E for
buildings in Risk Categories I, II, and III, and F for those in Risk Category IV, irrespective
of the above.
Seismic Design Category - "the more severe design category in accordance with
Table 11.6-1 or 11.6-2" = D
Note: See Section 11.6 for alternative approaches to calculating Seismic Design Category.
References
1. Figure 22-1: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-1.pdf
2. Figure 22-2: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-2.pdf
3. Figure 22-12: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-12.pdf
4. Figure 22-7: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-7.pdf
5. Figure 22-17: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-17.pdf
6. Figure 22-18: https://earthquake.usgs.gov/hazards/designmaps/downloads/pdfs/2010_ASCE-7_Figure_22-18.pdf
9/43
https://earthq uake.usgs.gov/cn2/des ig nmaps/us/report.php?te mplate=mi n i ma I&latitude=45.431229&long itud e=-122.771486&siteclass=3&riskcategory... 6/6
Seismic Lateral Design Analysis
Directionally Independent:
Design Parameters: Allowable Story Drift:
Structural Use Group= I 2nd Floor Allowable Drift,Aa= 3 in
Importance Factor,IE= 1.00
Site Class= D
Spectral Response Acceleration: Site Coefficients:
Ss= 97.2 %g Fa= 1.11
S = 42.3 %g Fv= 1.58
SMS=Ss Fa= 108.0 %g Seismic Design Category:
SMf=Si Fv= 66.7 %g SDC(SDs)= D
SDC(SD1)= D
SDS=A SMS= 72.0 %g SDC(Si)= A
SDf=%SMf= 44.5 %g Controlling Case—j D
0.2 SDS/1.4= 10.3 %g
Vertical Distribution Factor:
(h,)K W,
Level k h, (h,)k W. (h,)k W, Com= �(h
Roof 1 30.50 30.50 26,060 794,822 0.436
3rd Floor 1 21.00 21.00 35,713 749,979 0.412
2nd Floor 1 8.50 8.50 32,652 277,542 0.152
/,(hx)k W.= 1,822,344
Directionally Dependent:
Design Factors:
Response Modification Factor,R= 6.5
System Overstrength Factor,S2= 2.0
Deflection Amplification Factor,Cd= 4.0
Seismic Response Coefficient:
Cs=SD5/1.4(R/I)= 7.91 % Controls
Cs<_5D1/1.4[Tx(R/I)]=
Cs>0.044SDSI/1.4= 2.26
SDC=E or FSCs>(0.5 Si)/1.4(R/I) = 2.32 %
Base Shear: Vertical Distribution:
V=C5 W@ Roof Diaphragm= 2,062 lb VRoof=CvRoof VBase= 3,258 lb
V=Cs Waa 3rdDiaphragm= 2,825 lb VRoof=Cv2ndVBase= 3,074 lb
V=C5 Wa 2nd Diaphragm= 2,583 lb Vend=Cv2nd VBase= 1,138 lb
'= 7.470
10/43
f-
1)
.I.
4tC1 CO 1 I
43(-3
F ,
-...
j...) ...) ,
,---
1 i kr%
I 1
Ii
< ..i.
..... . .....„
,. ill ' 1
4 4-4.* I „ f—1.–I---h-
I V.
' i 1 ft'
vv. .......".
1 1 1 1 ', I I I
I ' I
1 e ..... 1---i-- f
1 °''' -:-1 li 4;1 .1....
,..... .1 . ......1".. A
-I k• ,1 i • i
r.,„...._.______o __i i• __;_____ ;i ;.,:; c..]
7
; ____________•,4_, ,
; -____.____ ,
_I___- -—- ----;I t ,
.
3 I : ..„-__-,:::.----.. —-
__ -..„
i
-"""•.".."......rt P....i............ .................................., ..............,......................
...,.............,...,*....,,,...,,..
..... i ......._;.! 4
.e
...0 '7' i• ', i --..----.- -----.; L,
q •-•' .
Cr "'",4.
1----4--- i
--
I —-—------_ - ""';'--m..-4 1
i
t'
t I .
1 I
H.,.i
....-----, 0 1 -WM 7 400011101011* ,10101001110.1
t 1
...-tt-
--I-- i
,
1 I 0
....._4111_ ,-
ir
\17 Mit :7 lira IA 4._tt-7,71).1titrti )
4------
.„..,„...
1
;
, r+i II-1
q o .
;
, ..... .,
.i*
I-, M4';'.
ivti - V 4
ta r-••-•r4S7) q..,e.-''' 1176
,-,
w
1
......
4r1t,:
'Hf() ell CsAi:A
_
I ,.....
m
ct
,....
rsi
1-1
eriSi
t4 ‘ rre.
7)1 1
S S
_
0 10,11 • —_
r- _
..-- .... -
1114.
41... ..).l'1
1----,---,i....................-..----.................... /
',. , ' iJ
I! !.I...........................-.-.-...........................
9 !-.;11(
t.—.' —-—---, '&4\ it
I: j4.---.....-..............,.....--..--.......-.. 4.P t 1
"4".
'0-----e--—'• ,_„„41._ ' :
D.'
,--—„ __,
---1 ;
--- —-— —----,
[
i q I
'Le ?"1 741 ..*.... .,..........,.............. i
'".*..".............`1
\‘.,,, -------..,--1---- --a------, r-
----- 1— _ ------ t 4'
„..--- -
.4,-4 i -* t‘44 - _I
qt. t --,--
---,-.4- ---..-------.:
-1 0
, 1
1
- 0, ......-...... ,_ ....41
' 3c n .
......._ k-it .....,
,..,
7 -..--
...
,.. ,
1 t ,
: co
I>
11.
_I
1
,..,
I
r •
Shearwall Load Distribution
ISageBuilt-Ash Creek,Plan 2179I
Seismic Forces
Seismic Base Shear,Vas= 7.5 kips
Roof Shear,Fi= 3.3 kips
3rd Floor Shear,Fi= 3.1 kips
2nd Floor Shear,Fi= 1.1 kips
fib Weights,f,„,..,= 3.00 psf
Trib Weights,fua,a= 323 psf
Trib Weights,fr a.o= 1.28 psf
SHEAR Sesimic SHEAR WALL WALL RATIO OF SHEAR ALONG SHEAR ALONG Height of Total Length Sum of Full Max Opening 1
(Wind) (Trib) (Seism=) IDEN. LENGTH TOTAL WALL WALL Wall of Wall Height Sheath. Height
SHEAR (Wind) (Seismic) H 1 5U Ha
(Ib) (Ib) (ft) (Ib) (Ib) (ft) (h) (ft) (ft)
(Roof to Upper Floor
Line A 1350 480 1441 AR-1 36.0 1.00 1350 1441 10 36 280 6.67
0.00 0 0 0
0.00 0 0 0
000 0 0 0
Total 36.0 1.00 1350 1441
Line B 1350 480 1441 00-1 21.5 100 1350 1441 B 21.5 19.5 6.67
000 0 0 0
000 0 0 0
0.00 0 0 0
Total 21.5 100 1350 1441
Line 1 2070 480 1441 1R-1 14.5 1.00 2070 1011 8 165 8.5 6.67
0 00 0 0 0
000 0 0 0
0.00 0 0 0
Total 14.5 1.00 2070 1441
Line 4 2070 480 1441 4R-1 16.75 1.00 2070 1441 10 16.75 6.75 6.67
0.00 0 0 0
0.00 0 0 0
0.00 0 0 0
Total 16.75 1.00 2070 1441
Upper to Main Floor INPUT INTO PERF SPREADSHEET
SHEAR Sesimic SHEAR WALL WALL RATIO OF SHEAR ALONG SHEAR ALONG Height of Total Length Sum of Full Max Opening
ALONG LINE (Trib) (Seismc) IDEN. LENGTH TOTAL WALL WALL Wall of Wall Height Sheath. Height
SHEAR (Wind) (Seismic) H L 511 Ho
(Ib) (lb) (ft) (Ib) (Ib) (ft) (h) (ft) (ft)
Line A 1710 480 1548 AM-1 30 1.00 3060 2990 9 30 26 6.67
Shear Above 1,350 1441 000 0 0 0
Total Shear 3060 2990 0.00 0 0 0
000 0 0 0
Total 30 1.00 3060 2990
Line 8 1710 480 1548 BM-1 21.5 1.00 3060 2990 9 21.5 13.5 6.67
Shear Above 1,350 1441 0.00 0 0 0
Total Shear 3060 2990 000 0 0 0
0.00 0 0 0
Total 21.5 100 3060 2990
Une 1 2622 480 1548 1M-1 14.5 1.00 4692 2990 9 14.5 14.5
Shear Above2,070 1441 000 0 0 0
Total Shear 4692 2990 0.00 0 0 0
0.00 0 0 0
Total 14.5 1.00 4692 2990
Line 4 2622 480 1548 4M-1 16.75 100 4692 2990 9 16.75 1675
Shear Above 2,070 1441 000 0 0 0
Total Shear 4692 2990 0.00 0 0 0
D.00 0 - 0 0
Total 16.75 1.00 4692 2990
Main Floor to Lower INPUT INTO PERE SPREADSHEET
SHEAR Sesimic SHEAR WALL WALL RATIO OF SHEAR ALONG SHEAR ALONG Height of Total Length Sum of Full Mao Opening
ALONG LINE (Trib) (Seismc) IGEN. LENGTH TOTAL WALL WALL Wall of Wall Height Sheath. Height
SHEAR (Wind) (Seismic) H L 5U Ho
(Ib) (Ib) (ft) (Ib) (Ib) (ft) (ft) (ft) (ft)
Line A 1530 430 1548 AL-1 -33 -- -I.TR) - 4590 4538 8 31 31
Shear Above 3,060 2990 000 0 0 0
Total Shear 4590 4538 000 0 0 0
0.00 0 0 0
Total 31 1.00 4590 4538
Line 9 1530 480 1548 BL-1 14.5 100 4590 4538 8 14.5 14.5
Shear Above 3,060 2990 000 0 0 0
Total Shear 0590 4538 0.00 0 0 0
0.00 0 0 0
Total 14.5 100 4590 4538
One 1 1020 168 542 1L-1 3.5 0.27 1538 951 8 3.5 3.5
Shear Above 0,692 2990 11-2 9.5 0.73 1174 2581 8 9.5 9.5
Total Shear 5712 3532 000 D 0 0
000 D 0 0
Total 13 1.00 5712 3532
Line 2 1785 420 1355 21-1 10.75 1.00 1785 1355 8 10.75 10/5
Shear Above 0.00 0 0 0
Total Shear 1785' 1355 0.00 0 0 0
000 0 0 0
Total 10.75 1.00 1785 1355
Line 3 1782 372 1200 31-1 1.25 0.50 891 600 4 1.25 1.25
Shear Above 3L-2 1.25 0.50 891 600 4 1.25 1.25
Total Shear 1782 1200 0.00 0 0 0
0.00 0 0 0
Total 2.5 1.00 1782 1200
13/43
M
V
ri
Irnl,le 900 P0.10 Net a.pea.a,rc Ps a..w mwnwWw,
Flo1.4.5.,091oX Pv9oEFEV on,.
^,,, NP0640511....s .,..,,,,,,,,,,,„,5,,,„N„,
109000 ., 990. 00.1 000 6,1 SZ 1 CO9 199 Z-If
resos.inax 104000 ew9 , nc ' y,c l6e
01 99F.1
f9905.0x (S6.: 99['1
.099O0N . r Ons 1009 ase0.o ON OM W 0 W 1 N 0 9u 00 196 (1191
67605-.1011 109.09 .6.9 ZS 0 61S SOS IsNxry
s-c606-20aN 169.09a I,O.., 0 ,Ll. asa woN 9950 x w 901 ms o0o ao, ao, .o na ,1 I 000 11 ,c essv 069 ,rn
N,e 0001 wf W.W
nWwrn•�0m mss.
nss90 99cs e 0 OH ,ro9 sc 9z
ss a6s'c
501 1-1,10
.151 ate 0909 9s m acs 096 ,ilayw. 099..9.' 911 s1, 096'9 0901
..,e 5091 a.e0Fa010v 9,e e50 099 oro vao c90 LEOWI -9N -910 c lv9 ss, DIE ass'c om'6 1-w,
ve.0 Sex rte 0 c,..l 0 509, a..,,,010N gen 9s rn 6v, EST u.0 veo na oo, .0 w e X99 9c OE o66'9 0000
!,e 150100 n 1 o90s xxtdL x01. 19
950 i, ao 90155 Es IA VVE ns [9, 1,'0 1110
,-bb
OnONdans 0 ,6,,, 999 «.a,au,o.9 M 95 s [9 09 000 190 , 1.10a 060 50 ,0 B 099 60 96 , , 1 056
1.es,M0nw1P.0
1911 fall Intl 1911 , 6s Illdl (ill) N16 OD MI Illi 1.11 141 1911 1911 ool..Nlnusp,
a oN 10...116 0 (491.01
)1. 5 0./...U. ,03 046,61.1 11141.949 5565 0 01.9.91 190990 1150
4149 100 o1
90 1 , 00 s
. PDA,M 69 14950 , w
00o 4W0
5s0
.00.1.1.1 In 1 v ,P.M 4.450 /.41450 ,n.itu,l •4,050 ....... sun ton w% II^i% 0opaws,5s 014E9 las, oil....dsy 11.m,s, .,,,u.,7.•6.4 nil s 4•o+1 in, lS sy.N ,.549 , 4s
f[ I [, II Il.mle1495N11I
9 6 I 9 .w
u .sp..o..4s104.wOvlw
731,9HA)=.l
1 ss 0,................. \\`L�—\l
s..M.lo. .,.Polm
.Ws P 9.0.uw
wN.mw49.Nlnl 6 9 Nn.las �173°.)/M=^
I oon.in.rb.0.,sw000..w
I s
190/40.3•14..he(0)PNM
I "- a a 1.02
9109
590 LLL 0
910c
5506
III 66'0 sc0
WO
/. —� 91 6IL'O91 - NO,
9160, 9109 %6Z/N FM IN I,%
1...5.....515.»5,AM AM M A ,w N w
,0i 6001 b>wxa.,IPv....,..b...c.L.5 Pn wi
6C1 Z Or,d'..5„49V-4.x tl.5f nrnab91N9091.05.0 .wM.u:ryf.0
4
Force Transfer Around Opening (FTAO)
Diekmann Method @ Mainr Floor Line 1 -1M-1
L� = 2.0ft Lo= 8.0 ft L2= 4.5 ft
V= 4.69k
vA= -302 plf vp= 832 plf vF= -302 plf hu= 1.0 ft
4- 4-
F1 = 2.05k F2= 4.61k
vB= 722 plf vo= 722 plf ho= 5.5 ft
F1 = 2.05k F2= 4.61k
hL= 2.5ft
vo= 402 pl vE=832 plf vH= -302 plf
T
H = 2.91k H= 2.91k
H= (4.69k *9.0ft) /14.5 ft= 2.91 k
vh= 4.69 k/ 6.5 ft= 722 plf
v„= 2.91 k/ 3.5 ft= 832 plf Use:Type S2 Shearwall
F= 832 plf* 8.00 ft= 6.66 k
F1= (6.66 k* 2.0 ft)/ 6.5 ft= 2.05 k Use:Cont.Simpson CMST14 STRAP
F2= (6.66k* 4.5 ft)/ 6.5 ft= 4.61 k
T+C Couple after Dead Load is applied for holdown requirements
MR= [( 18psf* 2 ft+ 13psf* 9.0 ft) *
(14.5 ft)^2 *0.6/2] +(0.0 ft *5001b)= 9.65 kft
T= 2.91 kft- (9.65 kft /14.5 ft) =2.25 k +3.18k= 5.43 k Use:Type CMST14 Strap
Force Transfer Around Opening (FTAO)
Diekmann Method @ Main Floor Line 4-4M-1
L1 = 3.3 ft Lo= 10.3 ft L2= 3.3 ft
V= 4.69 k
vA= -603 plf vo= 840 plf vF=-603 plf hu= 1.0 ft
4-
F� = 4.31k F2= 4.31k
vs= 722 plf vo=722 plf ho= 6.0 ft
F� = 4.31 k F2= 4.31 k
h = 2.0 ft
v�_ -603 plf VE= 840 plf vH= -603 plf
J� T
H = 2.52k H= 2.52k
H= (4.69k *9.0ft) /16.8 ft= 2.52 k
vh= 4.69 k/ 6.5 ft= 722 plf
v„= 2.52 k/ 3.0 ft= 840 plf Use:Type S2 Shearwall
F= 840 plf* 10.25 ft= 8.61 k
F1= (8.61 k* 3.3 ft)/ 6.5 ft= 4.31 k Use:Cont.Simpson CMSTCI6 STRAP
F2= (8.61 k* 3.3 ft)/ 6.5 ft= 4.31 k
T+C Couple after Dead Load is applied for holdown requirements
MR= [( 18psf* 2 ft+ 13psf* 9.0 ft)*
(16.8 ft)^2 *0.6/2] +(0.0ft *5001b)= 12.88 kft
T= 2.52 kft- ( 12.88 kft /16.8 ft) =1.75 k +4.04k= 5.80 k Use:Type CMST14 Strap
Force Transfer Around Opening (FTAO)
Diekmann Method @ Lower Floor Line B-BL-1
• = 8.0 ft Lo= 2.0 ft L2= 4.0 ft
V= 4.59k
vA= 295 Of vo= 525 plf vF= 295 plf hu= 1.0 ft
F1 = 0.70 k F2= 0.35 k
vs= 383 Of vo= 383 plf ho= 3.0 ft
F� = 0.70k F2= 0.35k
hL= 4.O ft
vc= 295 plf vs= 525 plf vH= 295 plf
Jf T
H= 2.62k H= 2.62k
H= (4.59k *8.0ft) /14.0 ft= 2.62 k
vh= 4.59 k/ 12.0 ft= 383 plf
v„= 2.62 k/ 5.0 ft= 525 plf Use:Type S2 Shearwall
F= 525 plf* 2.00 ft= 1.05 k
F1 = ( 1.05 k* 8.0 ft)/ 12.0 ft= 0.70 k Use:Cont.Simpson CS18 STRAP
F2= ( 1.05 k* 4.0 ft)/ 12.0 ft= 0.35 k
T+C Couple after Dead Load is applied for holdown requirements
MR= [( 18psf* 4 ft+ 13psf* 8.0 ft)*
(14.0 ft)^2 *0.6/2] +(0.0 ft *5001b)= 10.35 kft
T= 2.62 kft- ( 10.35 kft /14.0 ft) =1.88 k +2.76k= 4.64 k Use:Type Simpson HDU8 Anchor
_HDM-1 HDM-1 BM-3
- I fn' 1 'Llr 1111Tf71 co
,1 „ „ „ , „ „ „ „ „ 1 1 1
}o 11 I I I `„ I I III ; HDM_1N
1 h111111111111111111 1' �!
I I I
1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 ,1 02 0
1 [ 11JIIII __ B —_41 _IWW _11
11777 i1
SII �h
I
10 I 1 I i� T1 1 I ' TI'A —T IL, - -
I
1 1 1 �1 1 1 1 —TI-- F,
I 1`i4 J._",____yI.LLL11� ____JL_ _. -
BM-3 HDM-1 HDM-2
imHDR-1
HDR-1 1 aI Ei 11 illillri . :-.
Sn
_ 4---
— - , i",jI I c 1 I I`-1�1 I 1 1 1
HDR1 , II ;1yr #� I�,IIIII I L. �
, 1 III 1 ill 1 I
F—' — 1 I I I HDR-2 j II I, n i i OE
___ 111
.1111111111111 _.. 111111=1111111 —. _ MO
HDR-1
18/43
a
r---1 r–�
I ■ I - 1
--- 177'77 7, I
Ii li'
i LL'-',1„'
I
d Ir.;---1----;:____'
Li7 �III ---Ft.r--
I I
-. I
MSB 1 i
,i rj
a,
—
11
En
,E 0iiffilmm' . - X- 77
L_J t_J
MBM-4
— — —
W
1 w-- O7--------�1----HDL-1
1 E-- ' __moi----- U x
4� ----- —� 1 0
V--I ------–�jI.
1j
MBM 4 ] ffiif2.1T
1 -W--� 0-- —
1 1 1 1 1 FH '�r�rr —_� r
11 11111 I{11Y11 II 1., 7r---
Li� 1 1 1 1 1 1 ' 1 Y 1 1 N-- Ir I „
■ is---- LLLAAJ L_.�--"---�' ----=r
HDL-1 HDL-1
19/43
Project:Gravity Calcs � StruCalc 9.0 page
Location:FJ-1 s•4000%
Floor
Floor Joist of
[2015 International Building Code(2015 NDS)]
RFPI-400/11.875-Roseburg Forest Products x 16.5 FT @ 19.2 O.C.
Section Adequate By:6.2% StruCalc Version 10.0.1.5 1/23/2018 6:21:11 PM
Controlling Factor:Deflection
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.36 IN L/554
Dead Load 0.16 in
Total Load 0.52 IN L/382
Live Load Deflection Criteria:L/480 Total Load Deflection Criteria:U360
REACTIONS A
Live Load 528 lb 528 lb
Dead Load 238 lb 238 lb
Total Load 766 lb 766 lb
Bearing Length 5.50 in 3.50 in
Web Stiffeners No No
SUPPORT LOADS A
Live Load 330 plf 330 plf 16.5 ft
Dead Load 149 plf 149 plf
Total Load 479 plf 479 plf
I-JOIST PROPERTIES JOIST DATA Center
RFPI-400/11.875-Roseburg Forest Products Span Length 16.5 ft
Base Values Adjusted Unbraced Length-Top 0 ft
Moment Cap: Mcap= 4315 ft-lb Mcap'= 4315 ft-lb Unbraced Length-Bottom 0 ft
Cd=1.00 Floor sheathing applied to top of joists-top of joists fully braced.
Shear Stress: Vcap= 1420 lb Vcap'= 1420 lb Floor Duration Factor 1.00
Cd=1.00 JOIST LOADING
Reaction A: Rcap= 1380 lb Rcap'= 1380 lb Uniform Floor Loading Center
Reaction B: Rcap= 1380 lb Rcap'= 1380 lb
E.I.: El= 330 lb-int El'= 330 Ib-int Live Load LL= 40 psf
Dead Load DL= 18 psf
Controlling Moment: 3158 ft-lb Total Load TL= 58 psf
8.25 Ft from left support of span 3(Right Span) TLAdj.For Joist Spacing wT= 92.8 plf
Created by combining all dead and live loads.
Controlling Shear: -766 lb
16.0 Ft from left support of span 2(Center Span)
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
E.I.: 311 in2-lb E6 330 int-lb xE6
Moment: 3158 ft-lb 4315 ft-lb
Shear: -766 lb 1420 lb
20/43
Project:Gravity Gales StruCalc 9.0 Page
Location:HDR-1 ,, -�
Roof Beam
,, of
[2015 International Building Code(2015 NDS)] ;f` y
3.5 IN x 7.25 IN x 6.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:11 PM
Section Adequate By:42.5%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.05 IN L/1351
Dead Load 0.03 in
Total Load 0.09 IN L/819
Live Load Deflection Criteria:L/240 Total Load Deflection Criteria:L/180
REACTIONS A
Live Load 975 lb 975 lb
Dead Load 633 lb 633 lb
Total Load 1608 lb 1608 lb
Bearing Length 0.74 in 0.74 in
BEAM DATA
Span Length 6 ft
Unbraced Length-Top 0 ft 6ft
Unbraced Length-Bottom 0 ft
Roof Pitch 4 :12
Roof Duration Factor 1.15 ROOF LOADING
MATERIAL PROPERTIES Side One:
#2-Douglas-Fir-Larch Roof Live Load: LL= 25 psf
Base Values Adjusted Roof Dead Load: DL= 15 psf
Bending Stress: Fb= 900 psi Fb'= 1346 psi Tributary Width: TW= 13 ft
Cd=1.15 CF=1.30 Side Two:
Shear Stress: Fv= 180 psi Fv'= 207 psi Roof Live Load: LL= 0 psf
Cd=1.15 Roof Dead Load: DL= 0 psf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Tributary Width: TW= 0 ft
Comp.±to Grain: Fc-L= 625 psi Fc-1'= 625 psi
Wall Load: WALL= 0 plf
Controlling Moment: 2412 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
3.0 ft from left support
Created by combining all dead and live loads. Adjusted Beam Length: Ladj= 6 ft
Controlling Shear: 1608 Ib Beam Self Weight: BSW= 6 plf
At support. Beam Uniform Live Load: wL= 325 plf
Beam Uniform Dead Load: wD_adj= 211 plf
Created by combining all dead and live loads. Total Uniform Load: wT= 536 plf
Comparisons with required sections: Req'd Provided
Section Modulus: 21.51 in3 30.66 in3
Area(Shear): 11.65 in2 25.38 in2
Moment of Inertia(deflection): 24.42 in4 111.15 in4
Moment: 2412 ft-lb 3438 ft-lb
Shear: -1608 lb 3502 lb
21/43
Project:Gravity Calcs z,. a StruCalc 9.0 page
Location: HDR-3 1T1 Z
Roof Beam of
[2015 International Building Code(2015 NDS)] ;.:1L-.
5.5 INx11.5INx10.0FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:11 PM
Section Adequate By:37.9%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.09 IN L/1325
Dead Load 0.06 in
Total Load 0.15 IN L/801
Live Load Deflection Criteria:U240 Total Load Deflection Criteria:L/180
REACTIONS A B
Live Load 1650 lb 1650 lb
Dead Load 1091 lb 1091 lb
Total Load 2741 lb 2741 lb 1 2
Bearing Length 0.80 in 0.80 in
BEAM DATA ..
Span Length 10 ft
Unbraced Length-Top 0 ft to ft
Unbraced Length-Bottom 0 ft
Roof Pitch 4 :12
Roof Duration Factor 1.15 ROOF LOADING
MATERIAL PROPERTIES Side One:
#2-Douglas-Fir-Larch Roof Live Load: LL= 25 psf
Base Values Adjusted Roof Dead Load: DL= 15 psf
Bending Stress: Fb= 875 psi Fb'= 1006 psi Tributary Width: TW= 8 ft
Cd=1.15 CF=1.00 Side Two:
Shear Stress: Fv= 170 psi Fv'= 196 psi Roof Live Load: LL= 0 psf
Cd=1.15 Roof Dead Load: DL= 0 psf
Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Tributary Width: TW= 0 ft
Comp.L to Grain: Fc-L= 625 psi Fc-L'= 625 psi
Wall Load: WALL= 0 plf
Controlling Moment: 7373 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
5.0 ft from left support Adjusted Beam Length: Ladj= 10 ft
Created by combining all dead and live loads. Beam Self Weight: BSW= 14 plf
Controlling Shear: -2741 lb Beam Uniform Live Load: wL= 200 plf
At support. Beam Uniform Dead Load: wD_adj= 140 plf
Created by combining all dead and live loads. Total Uniform Load: wT= 340 plf
Comparisons with required sections: Req'd Provided POINT LOADS-CENTER SPAN
Section Modulus: 87.92 in3 121.23 in3 Load Number One Two
Area(Shear): 21.03 in2 63.25 in2 Live Load 650 lb 650 lb
Moment of Inertia(deflection): 156.73 in4 697.07 in4 Dead Load 390 lb 390 lb
Moment: 7373 ft-lb 10166 ft-lb Location 3 ft 7 ft
Shear: -2741 lb 8244 lb
22/43
Project:Gravity Calcs j, StruCalc 9.0 page
Location:HDR-2
Roof Beam
of
[2015 International Building Code(2015 NDS)]
5.5INx11.5INx5.0FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:12 PM
Section Adequate By:56.4%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.02 IN L/3538
Dead Load 0.01 in
Total Load 0.03 IN U2181
Live Load Deflection Criteria:L/240 Total Load Deflection Criteria:L/180
REACTIONS A
Live Load 2013 lb 2013 lb
Dead Load 1268 lb 1268 lb
Total Load 3281 lb 3281 lb
Bearing Length 0.95 in 0.95 in
BEAM DATA
Span Length 5 ft
Unbraced Length-Top 0 ft 45 n
Unbraced Length-Bottom 0 ft
Roof Pitch 4 :12
Roof Duration Factor 1.15 ROOF LOADING
MATERIAL PROPERTIES Side One:
#2-Douglas-Fir-Larch Roof Live Load: LL= 25 psf
Base Values Adjusted Roof Dead Load: DL= 15 psf
Bending Stress: Fb= 875 psi Fb'= 1006 psi Tributary Width: TW= 13 ft
Cd=1.15 CF=/.00 Side Two:
Shear Stress: Fv= 170 psi Fv'= 196 psi Roof Live Load: LL= 0 psf
Cd=1.15 Roof Dead Load: DL= 0 psf
Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Tributary Width: TW= 0 ft
Comp.L to Grain: Fc-L= 625 psi Fc-L'= 625 psi
Wall Load: WALL= 0 plf
Controlling Moment: 6501 ft-lb SLOPE/PITCH ADJUSTED LENGTHS AND LOADS
2.5 ft from left support Adjusted Beam Length: Ladj= 5 ft
Created by combining all dead and live loads.
Controlling Shear: 3281 lb Beam Self Weight: BSW= 14 plf
Beam Uniform Live Load: wL= 325 plf
At support. Beam Uniform Dead Load: wD_adj= 219 plf
Created by combining all dead and live loads. Total Uniform Load: wT= 544 plf
Comparisons with required sections: Req'd Provided POINT LOADS-CENTER SPAN
Section Modulus: 77.53 in3 121.23 in3 Load Number One
Area(Shear): 25.17 in2 63.25 in2 Live Load 2400 lb
Moment of Inertia(deflection): 57.53 in4 697.07 in4 Dead Load 1440 lb
Moment: 6501 ft-lb 10166 ft-lb Location 2.5 ft
Shear: 3281 lb 8244 lb
23/43
Project:Gravity Calcs �, �� StruCalc 9.0 page
,04
Location:HDM-1 .0.
Combination Roof And Floor Beam of
[2015 International Building Code(2015 NDS)]
3.5 IN x 7.25 IN x 4.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6.21.12 PM
Section Adequate By:71.9%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.02 IN L/2298
Dead Load 0.01 in
Total Load 0.03 IN L/1482
Live Load Deflection Criteria:1/360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 1290 lb 1290 lb
Dead Load 710 lb 710 lb
Total Load 2000 lb 2000 lb
Bearing Length 0.91 in 0.91 in
BEAM DATA Center
Span Length 4 ft
Unbraced Length-Top 0 ft Oft
Roof Pitch 4 :12
Floor Duration Factor 1.00
Roof Duration Factor 1.15 ROOF LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Roof Live Load RLL= 25 psf 0 psf
#2-Douglas-Fir-Larch Roof Dead Load RDL= 15 psf 0 psf
Base Values Adjusted Roof Tributary Width RTW= 13 ft 0 ft
Bending Stress: Fb= 900 psi Fb'= 1346 psi
Cd=1.15 CF=1.30 FLOOR LOADING
Shear Stress: Fv= 180 psi Fv'= 207 psi Side 1 Side 2
Cd=1.15 Floor Live Load FLL= 40 psf 0 psf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Floor Dead Load FDL= 18 psf 0 psf
Comp. L to Grain: Fc- = 625 psi Fc-1'= 625 psi Floor Tributary Width FTW= 8 ft 0 ft
Controlling Moment: 2000 ft-lb Wall Load WALL= 0 plf
2.0 ft from left support BEAM LOADING
Created by combining all dead and live loads. Roof Uniform Live Load: wL-roof= 325 plf
Controlling Shear: -2000 lb Roof Uniform Dead Load: wD-roof= 206 plf
At support. Floor Uniform Live Load: wL-floor= 320 plf
Created by combining all dead and live loads. Floor Uniform Dead Load: wD-floor= 144 plf
Beam Self Weight: BSW= 6 plf
Comparisons with required sections: Req'd Provided Combined Uniform Live Load: wL= 645 plf
Section Modulus: 17.84 in3 30.66 in3 Combined Uniform Dead Load: wD= 355 plf
Area(Shear): 14.49 int 25.38 in2 Combined Uniform Total Load: wT= 1000 plf
Moment of Inertia(deflection): 18 in4 111.15 in4
Moment: 2000 ft-lb 3438 ft-lb
Shear: -2000 lb 3502 lb
24/43
Project:Gravity Cales0�, StruCalc 9.0 page
Location:HDM-2
Combination Roof And Floor Beam or
[2015 International Building Code(2015 NDS)] .:w . ..,
5.5 IN x 11.5 IN x 6.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:12 PM
Section Adequate By:73.7%
Controlling Factor:Moment
PEFLECTIONS Center LOADING DIAGRAM
Live Load 0.02 IN U3087
Dead Load 0.01 in
Total Load 0.04 IN L/1909
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A B
Live Load 1815 lb 1815 lb
Dead Load 1126 lb 1126 lb
Total Load 2941 lb 2941 lb
Bearing Length 0.86 in 0.86 in
BEAM DATA Center , ,
Span Length 6 ft
4
Unbraced Length-Top 0 ft Eft
Roof Pitch 4 :12
Floor Duration Factor 1.00
Roof Duration Factor 1.15 ROOF LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Roof Live Load RLL= 25 psf 0 psf
#2-Douglas-Fir-Larch Roof Dead Load RDL= 15 psf 0 psf
Base Values Adjusted Roof Tributary Width RTW= 13 ft 0 ft
Bending Stress: Fb= 875 psi Fb'= 1006 psi
Cd=1.15 CF=1.00 FLOOR LOADING
Shear Stress: Fv= 170 psi Fv'= 196 psi Side 1 Side 2
Cd=1.15 Floor Live Load FLL= 40 psf 0 psf
Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi Floor Dead Load FDL= 18 psf 0 psf
Comp.±to Grain: Fc-±= 625 psi Fc--L'= 625 psi Floor Tributary Width FTW= 2 ft 0 ft
Controlling Moment: 5851 ft-lb Wall Load WALL= 0 plf
3.0 ft from left support
Created by combining all dead and live loads. BEAM LOADING
Controlling Shear: 2941 lb Roof Uniform Live Load: wL-roof= 325 plf
Roof Uniform Dead Load: wD-roof= 206 plf
At support. Floor Uniform Live Load: wl-floor= 80 plf
Created by combining all dead and live loads. Floor Uniform Dead Load: wD-floor= 36 plf
Beam Self Weight: BSW= 14 plf
Comparisons with required sections: Req'd Provided Combined Uniform Live Load: wL= 405 plf
Section Modulus: 69.78 in3 121.23 in3 Combined Uniform Dead Load: wD= 255 plf
Area(Shear): 22.56 in2 63.25 in2 Combined Uniform Total Load: wT= 660 plf
Moment of Inertia(deflection): 87.64 in4 697.07 in4
Moment: 5851 ft-lb 10166 ft-lb POINT LOADS-CENTER SPAN
Shear: 2941 lb 8244 lb Load Number One
Live Load 1200 lb
Dead Load 720 lb
Location 3 ft
25/43
Project:Gravity Calcs <,[ StruCalc 9.0 page
Location:HDM-3
Uniformly Loaded Floor Beam 41104# of
[2015 International Building Code(2015 NDS)]
3.5 IN x 7.25 IN x 10.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:13 PM
Section Adequate By:96.8%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.10 IN L/1186
Dead Load 0.05 in
Total Load 0.15 IN L/781
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A_
Live Load 400 lb 400 lb
Dead Load 208 lb 208 lb
Total Load 608 lb 608 lb
Bearing Length 0.28 in 0.28 in
BEAM DATA Center
Span Length 10 ft
Unbraced Length-Top 0 ft --loft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 900 psi Fb'= 1170 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.30 Floor Tributary Width FTW= 2 ft 0 ft
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1600 ksi E= 1600 ksi BEAM LOADING
Comp.L to Grain: Fc- L= 625 psi Fc-1'= 625 psi Beam Total Live Load: wL= 80 plf
Controlling Moment: 1519 ft-lb Beam Total Dead Load: wD= 36 plf
5.0 ft from left support Beam Self Weight: BSW= 6 plf
Created by combining all dead and live loads. Total Maximum Load: wT= 122 plf
Controlling Shear: -608 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 15.58 in3 30.66 in3
Area(Shear): 5.06 in2 25.38 in2
Moment of Inertia(deflection): 34.17 in4 111.15 in4
Moment: 1519 ft-lb 2989 ft-lb
Shear: -608 lb 3045 lb
26/43
Project:Gravity Calcs StruCalc 9.0 page
Location: HDM-4
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)] ;4;4.:
'.
3.5 IN x 7.25 IN x 3.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:13 PM
Section Adequate By:215.5%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.00 IN L/7985
Dead Load 0.00 in
Total Load 0.01 IN L/5460
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 660 lb 660 lb
Dead Load 305 lb 305 lb
Total Load 965 lb 965 lb
Bearing Length 0.44 in 0.44 in
BEAM DATA Center
Span Length 3 ft
Unbraced Length-Top 0 ft aft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 900 psi Fb'= 1170 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.30 Floor Tributary Width FTW= 11 ft 0 ft
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING
Comp.1 to Grain: Fc- = 625 psi Fc- = 625 psi Beam Total Live Load: wL= 440 plf
Controlling Moment: 724 ft-lb Beam Total Dead Load: wD= 198 plf
1.5 ft from left support Beam Self Weight: BSW= 6 plf
Total Maximum Load: wT= 644 plf
Created by combining all dead and live loads.
Controlling Shear: 965 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 7.43 in3 30.66 in3
Area(Shear): 8.04 in2 25.38 in2
Moment of Inertia(deflection): 5.01 in4 111.15 in4
Moment: 724 ft-lb 2989 ft-lb
Shear: 965 lb 3045 lb
27/43
Project_Gravity Calcs StruCalc 9.0 page
Location: BM-1
Uniformly Loaded Floor Beam of/
[2015 International Building Code(2015 NDS)]
1.75 IN x 11.875 IN x 8.0 FT
1.55E Timberstrand LSL-iLevel Trus Joist StruCalc Version 10.0.1.5 1/23/2018 6:21:13 PM
Section Adequate By:181.3%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.06 IN L/1643
Dead Load 0.03 in
Total Load 0.09 IN L/1112
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTION$ A
Live Load 960 lb 960 lb
Dead Load 458 lb 458 lb
Total Load 1418 lb 1418 lb
Bearing Length 0.90 in 0.90 in
BEAM DATA Center
Span Length 8 ft
4—
Un braced Length-Top 0 ft
418n
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
1.55E Timberstrand LSL-iLevel Trus Joist Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 2325 psi Fb'= 2327 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 6 ft 0 ft
Shear Stress: Fv= 310 psi Fv'= 310 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1550 ksi E'= 1550 ksi BEAM LOADING
Comp.L to Grain: Fc---= 900 psi Fc-1'= 900 psi Beam Total Live Load: wL= 240 plf
Controlling Moment: 2836 ft-lb Beam Total Dead Load: wD= 108 plf
4.0 ft from left support Beam Self Weight: BSW= 6 plf
Total Maximum Load: wT= 354 plf
Created by combining all dead and live loads.
Controlling Shear: 1418 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 14.62 in3 41.13 in3
Area(Shear): 6.86 in2 20.78 in2
Moment of Inertia(deflection): 53.5 in4 244.21 in4
Moment: 2836 ft-lb 7977 ft-lb
Shear: 1418 lb 4295 lb
28/43
Project:Gravity Calcs StruCalc 9.0 page
Location:BM-2 ,v�,:Ew .
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)] ,".'-
1.75 IN x 11.875 IN x 8.0 FT
1.55E Timberstrand LSL-iLevel Trus Joist StruCalc Version 10.0.1.5 1/23/2018 6:21:14 PM
Section Adequate By:714.0%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.02 IN L/4929
Dead Load 0.01 in
Total Load 0.03 IN L/3219
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 320 lb 320 lb
Dead Load 170 lb 170 lb
Total Load 490 lb 490 lb
Bearing Length 0.31 in 0.31 in
BEAM DATA Center
Span Length 8 ft
Unbraced Length-Top 0 ft 8 n
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
1.55E Timberstrand LSL-iLevel Trus Joist Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 2325 psi Fb'= 2327 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1 00 Floor Tributary Width FTW= 2 ft 0 ft
Shear Stress: Fv= 310 psi Fv'= 310 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1550 ksi E'= 1550 ksi BEAM LOADING
Comp.L to Grain: Fc- = 900 psi Fc-1'= 900 psi Beam Total Live Load: wL= 80 plf
Controlling Moment: 980 ft-lb Beam Total Dead Load: wD= 36 plf
Controlling
r from left Momsupent:
Beam Self Weight: BSW= 6 plf
Total Maximum Load: wT= 122 plf
Created by combining all dead and live loads.
Controlling Shear: 490 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 5.05 in3 41.13 in3
Area(Shear): 2.37 in2 20.78 in2
Moment of Inertia(deflection): 18.21 in4 244.21 in4
Moment: 980 ft-lb 7977 ft-lb
Shear: 490 lb 4295 lb
29/43
Project:Gravity Calcs . -� StruCalc 9.0 page
Location:BM-3 vl ,
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)]
1.75 IN x 11.875 IN x 5.5 FT
1.55E Timberstrand LSL-iLevel Trus Joist StruCalc Version 10.0.1.5 1/23/2018 6:21:14 PM
Section Adequate By:554.8%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.01 IN U7585
Dead Load 0.00 in
Total Load 0.01 IN L/5089
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:U240
REACTIONS A
Live Load 440 lb 440 lb
Dead Load 216 lb 216 lb
Total Load 656 lb 656 lb
Bearing Length 0.42 in 0.42 in
BEAM DATA Center
Span Length 5.5 ft
Unbraced Length-Top 0 ft 5.5 ft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
1.55E Timberstrand LSL-iLevel Trus Joist Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 2325 psi Fb'= 2327 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 4 ft 0 ft
Shear Stress: Fv= 310 psi Fv'= 310 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1550 ksi E'= 1550 ksi BEAM LOADING
Comp. to Grain: Fc- = 900 psi Fc- = 900 psi Beam Total Live Load: wL= 160 plf
Controlling Moment: 902 ft-lb Beam Total Dead Load: wD= 72 plf
supporteBeam Self Weight: BSW= 6 plf
2.75ft lin from left
Total Maximum Load: wT= 238 plf
Created by combining all dead and live loads.
Controlling Shear: -656 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 4.65 in3 41.13 in3
Area(Shear): 3.17 in2 20.78 in2
Moment of Inertia(deflection): 11.59 in4 244.21 in4
Moment: 902 ft-lb 7977 ft-lb
Shear: -656 lb 4295 lb
30/43
Project:Gravity Calcs ,1,1p, StruCalc 9.0 page
Location: BM-4 �-
Multi-Span Floor Beam of
[2015 International Building Code(2015 NDS)]
3.5 IN x 11.875 IN x 28.0 FT(11 +5.5+ 11.5)
2.0 Rigidlam LVL-Roseburg Forest Products StruCalc Version 10.0.1.5 1/23/2018 6:21:15 PM
Section Adequate By:79.5%
Controlling Factor:Shear
DEFLECTIONS Left Center Right LOADING DIAGRAM
Live Load 0.11 IN L/1231 -0.03 IN U2544 0.10 IN L/1421
Dead Load 0.05 in -0.01 in 0.04 in
Total Load 0.16 IN U846 -0.04 IN L/1835 0.14 IN L/978
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 '
REACTIONS A B C D
Live Load 1970 lb 5123 lb 4328 lb 1782 lb
Dead Load 926 lb 2001 lb 1520 lb 838 lb
Total Load 2896 lb 7124 lb 5848 lb 2620 lb t
Uplift(1.5 F.S) 0 lb 0 lb -140 lb 0 lb
Bearing Length 1.10 in 2.71 in 2.23 in 1.00 in
BEAM DATALeif Center Right '
Span Length 11 ft 5.5 ft 11.5 ftAi: 11 ft� --41V5.5 ft 4 11.5 ft
il-
Unbraced Length-Top O ft O ft O ft
Unbraced Length-Bottom 11 ft 5.5 ft 11.5 ft
Floor Duration Factor 1.00 FLOOR LOADING Left Center Right
Notch Depth 0.00
Floor Live Load FLL= 40 psf 40 psf 40 psf
MATERIAL PROPERTIES Floor Dead Load FDL= 18 psf 18 psf 18 psf
2.0 Rigidlam LVL-Roseburg Forest Products Floor Tributary Width Side One TW1 = 9 ft 9 ft 9 ft
Base Values Adjusted Floor Tributary Width Side Two TW2= 0 ft 0 ft 0 ft
Bending Stress: Fb= 3100 psi Fb'= 2919 psi Wall Load WALL= 0 plf 0 plf 0 plf
Cd=1 00 CI=0.94 CF=1.00 POINT LOADS-LEFT SPAN
Shear Stress: Fv= 290 psi Fv'= 290 psi Load Number One
Cd=1.00 Live Load 960 lb
Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Dead Load 458 lb
Comp.L to Grain: Fc--L= 750 psi Fc--1-'= 750 psi Location 6.5 ft
Controlling Moment: 7820 ft Ib *Load obtained from Load Tracker.See Summary Report for details.
Over right support of span 1 (Left Span) BEAM LOADING Left Center Right
Created by combining all dead loads and live loads on span(s)1,2 Reduced Floor Live Load 40 psf 40 psf 40 psf
Controlling Shear: -4477 lb Total Live Load 360 plf 360 plf 360 plf
At right support of span 1 (Left Span) Total Dead Load 162 plf 162 plf 162 plf
Created by combining all dead loads and live loads on span(s)1,2 Beam Self Weight 10 plf 10 plf 10 plf
Total Load 532 plf 532 plf 532 plf
Comparisons with required sections: Req'd Provided
Section Modulus: 32.15 in3 82.26 in3
Area(Shear): 23.16 in2 41.56 in2
Moment of Inertia(deflection): 142.89 in4 488.41 in4
Moment: -7820 ft-lb 20008 ft-lb
Shear: -4477 lb 8035 lb
31/43
Project:Gravity Calcs 0,440„e StruCalc 9.0 page
Location: HDL-1 /
Combination Roof And Floor Beam _ of
[2015 International Building Code(2015 NDS)] =.
3.5 IN x 9.25 IN x 4.5 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:15 PM
Section Adequate By:158.0%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.01 IN L/4458
Dead Load 0.01 in
Total Load 0.02 IN L/2809
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A_
Live Load 1091 lb 1091 lb
Dead Load 640 lb 640 lb
Total Load 1731 lb 1731 lb
Bearing Length 0.79 in 0.79 in
BEAM DATA Center
Span Length 4.5 ft
Unbraced Length-Top 0 ft 4.5 ft
Roof Pitch 4 :12
Floor Duration Factor 1.00
Roof Duration Factor 1.15 ROOF LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Roof Live Load RLL= 25 psf 0 psf
#2-Douglas-Fir-Larch Roof Dead Load RDL= 15 psf 0 psf
Base Values Adjusted Roof Tributary Width RTW= 13 ft 0 ft
Bending Stress: Fb= 900 psi Fb'= 1242 psi
Cd=1.15 CF=1.20 FLOOR LOADING
Shear Stress: Fv= 180 psi Fv'= 207 psi Side 1 Side 2
Cd=1.15 Floor Live Load FLL= 40 psf 0 psf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi Floor Dead Load FDL= 18 psf 0 psf
Comp.1 to Grain: Fc- = 625 psi Fc--- = 625 psi Floor Tributary Width FTW= 4 ft 0 ft
Controlling Moment: 1948 ft-lb Wall Load WALL= 0 plf
2.25 ft from left support
Created by combining all dead and live loads. BEAM LOADING
Controlling Shear: 1732 Ib Roof Uniform Live Load: wL-roof= 325 plf
At support. Roof Uniform Dead Load: wD-roof= 206 plf
Created by combining all dead and live loads. Floor Uniform Live Load: wL-floor= 160 plf
Floor Uniform Dead Load: wD-floor= 72 plf
Beam Self Weight: BSW= 7 plf
Comparisons with required sections: Req'd Provided Combined Uniform Live Load: wL= 485 plf
Section Modulus: 18.82 in3 49.91 in3 Combined Uniform Dead Load: wD= 285 plf
Area(Shear): 12.55 in2 32.38 in2 Combined Uniform Total Load: wT= 770 plf
Moment of Inertia(deflection): 19.72 in4 230.84 in4
Moment: 1948 ft-lb 5166 ft-lb
Shear: -1732 lb 4468 lb
32/43
Project:Gravity Calcs StruCalc 9.0 page
11.
Location: HDL-2 /
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)] FW-
5.5 IN x 11.5 IN x 3.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:15 PM
Section Adequate By:16.9%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.00 IN L/MAX
Dead Load 0.00 in
Total Load 0.00 IN L/8970
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 4389 lb 974 lb
Dead Load 1742 lb 408 lb
Total Load 6131 lb 1382 lb
Bearing Length 1.78 in 0.40 in
BEAM DATA Center
Span Length 3 ft
Unbraced Length-Top 0 ft aft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 875 psi Fb'= 875 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 2 ft 0 ft
Shear Stress: Fv= 170 psi Fv'= 170 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1300 ksi E'= 1300 ksi BEAM LOADING
Comp. L to Grain: Fc-1= 625 psi Fc-1'= 625 psi Beam Total Live Load: wL= 80 plf
Controlling Moment: 3039 ft-lb Beam Total Dead Load: wD= 36 plf
1.5 ft from left support Beam Self Weight: BSW= 14 plf
Total Maximum Load: wT= 130 plf
Created by combining all dead and live loads.
Controlling Shear: 6131 lb POINT LOADS-CENTER SPAN
At support. Load Number One *
Created by combining all dead and live loads. Live Load 5123 lb
Dead Load 2001 lb
Comparisons with required sections: Req'd Provided Location 0.5 ft
Section Modulus: 41.68 in3 121.23 in3 *Load obtained from Load Tracker.See Summary Report for details.
Area(Shear): 54.1 in2 63.25 in2
Moment of Inertia(deflection): 19.94 in4 697.07 in4
Moment: 3039 ft-lb 8840 ft-lb
Shear: 6131 lb 7168 lb
33/43
Project:Gravity Calcs StruCalc 9.0 page
• •
Location:MBM-1 A ,
Uniformly Loaded Floor Beam 4proo,
or
[2015 International Building Code(2015 NDS)] -:
3.5 IN x 11.875 IN x 14.0 FT
2.0 Rigidlam LVL-Roseburg Forest Products StruCalc Version 10.0.1.5 1/23/2018 6:21:16 PM
Section Adequate By:36.3%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.26 IN L/656
Dead Load 0.11 in
Total Load 0.36 IN L/464
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 4270 lb 1178 lb
Dead Load 1628 lb 542 lb
Total Load 5898 lb 1720 lb 1
Bearing Length 2.25 in 0.66 in
BEAM DATA Center
Span Length 14 ft
Unbraced Length-Top 0 ft —— Marc
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
2.0 Rigidlam LVL-Roseburg Forest Products Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 3100 psi Fb'= 3104 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 2 ft 0 ft
Shear Stress: Fv= 290 psi Fv'= 290 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi BEAM LOADING
Comp.l to Grain: Fc- L= 750 psi Fc- L'= 750 psi Beam Total Live Load: wL= 80 plf
Beam Total Dead Load: wD= 36 plf
Controlling Moment: 11521 ft-lb Beam Self Weight: BSW= 10 plf
7.0 ft from left support Total Maximum Load: wT= 126 plf
Created by combining all dead and live loads.
Controlling Shear: 5897 lb POINT LOADS-CENTER SPAN
At support. Load Number One
Created by combining all dead and live loads. Live Load 4328 lb
Dead Load 1520 lb
Comparisons with required sections: Req'd Provided Location 2 ft
Section Modulus: 44.54 in3 82.26 in3 *Load obtained from Load Tracker.See Summary Report for details.
Area(Shear): 30.5 in2 41.56 in2
Moment of Inertia(deflection): 268.11 in4 488.41 in4
Moment: 11521 ft-lb 21278 ft-lb
Shear: 5897 lb 8035 lb
34/43
Project:Gravity Calcs Y,fsf StruCalc 9.0 page
Location:MBM-2
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)]
1.75 IN x 11.875 IN x 8.0 FT
1.55E Timberstrand LSL-iLevel Trus Joist StruCalc Version 10.0.1.5 1/23/2018 6:21:16 PM
Section Adequate By:141.7%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.07 IN L/1408
Dead Load 0.03 in
Total Load 0.10 IN L/956
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240
REACTIONS A B
Live Load 1120 lb 1120 lb
Dead Load 530 lb 530 lb
Total Load 1650 lb 1650 lb
Bearing Length 1.05 in 1.05 in
BEAM DATA Center
Span Length 8 ft
Unbraced Length-Top 0 ft 8 R
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
1.55E Timberstrand LSL-iLevel Trus Joist Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 2325 psi Fb'= 2327 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 7 ft 0 ft
Shear Stress: Fv= 310 psi Fv'= 310 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1550 ksi E'= 1550 ksi BEAM LOADING
Comp.L to Grain: Fc- = 900 psi Fc-1'= 900 psi
Beam Total Live Load: wL= 280 plf
Beam Total Dead Load: wD= 126 plf
Controlling Moment: 3300 ft-lb Beam Self Weight: BSW= 6 plf
4.0 ft from left support
Total Maximum Load: wT= 412 plf
Created by combining all dead and live loads.
Controlling Shear: 1650 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 17.02 in3 41.13 in3
Area(Shear): 7.98 in2 20.78 in2
Moment of Inertia(deflection): 62.42 in4 244.21 in4
Moment: 3300 ft-lb 7977 ft-lb
Shear: 1650 lb 4295 lb
35/43
roject:Gravity Calcs � �, StruCalc 9.0 page
J
Location:HDL-3 `r,
Uniformly Loaded Floor Beam of
[2015 International Building Code(2015 NDS)] -- —
3.5INx7.25INx4.0FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:16 PM
Section Adequate By:132.3%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.01 IN L/3369
Dead Load 0.01 in
Total Load 0.02 IN L/2303
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:U240
REACTIONS A
Live Load 880 lb 880 lb
Dead Load 407 lb 407 lb
Total Load 1287 lb 1287 lb
Bearing Length 0.59 in 0.59 in
BEAM DATA Center
_
iiii
Span Length 4 ft .__. o�""w
Unbraced Length-Top 0 ft •
4ft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 900 psi Fb'= 1170 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.30 Floor Tributary Width FTW= 11 ft 0 ft
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING
Comp.l to Grain: Fc- = 625 psi Fc-1'= 625 psi Beam Total Live Load: wL= 440 plf
Controlling Moment: 1287 ft-lb Beam Total Dead Load: wD= 198 plf
2.0 ft from left support Beam Self Weight: BSW= 6 plf
Created by combining all dead and live loads. Total Maximum Load: wT= 644 plf
Controlling Shear: -1287 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 13.2 in3 30.66 in3
Area(Shear): 10.73 in2 25.38 in2
Moment of Inertia(deflection): 11.88 in4 111.15 in4
Moment: 1287 ft-lb 2989 ft-lb
Shear: -1287 lb 3045 lb
36/43
Project:Gravity Calcs StruCalc 9.0 Page
Location: MBM-5 /•M
Uniformly Loaded Floor Beam or
[2015 International Building Code(2015 NDS)] :.' -.
1.75 IN x 11.875 IN x 6.0 FT
1.55E Timberstrand LSL-iLevel Trus Joist StruCalc Version 10.0.1.5 1/23/2018 6:21:17 PM
Section Adequate By:103.8%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.04 IN L/1947
Dead Load 0.02 in
Total Load 0.05 IN L/1331
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:U240
REACTIONS A
Live Load 1440 lb 1440 lb
Dead Load 667 lb 667 lb
Total Load 2107 lb 2107 lb
Bearing Length 1.34 in 1.34 in
BEAM DATA Center
Span Length 6 ft
Unbraced Length-Top 0 ft 6ft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
1.55E Timberstrand LSL-iLevel Trus Joist Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 2325 psi Fb'= 2327 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Floor Tributary Width FTW= 12 ft 0 ft
Shear Stress: Fv= 310 psi Fv'= 310 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1550 ksi E'= 1550 ksi BEAM LOADING
Comp.L to Grain: Fc-L= 900 psi Fc-L'= 900 psi Beam Total Live Load: wL= 480 plf
Beam Total Dead Load: wD= 216 plf
Controlling Moment: 3161 ft-lb Beam Self Weight: BSW= 6 plf
3.0 ft from left support Total Maximum Load: wT= 702 plf
Created by combining all dead and live loads.
Controlling Shear: -2107 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 16.3 in3 41.13 in3
Area(Shear): 10.2 in2 20.78 in2
Moment of Inertia(deflection): 45.14 in4 244.21 in4
Moment: 3161 ft-lb 7977 ft-lb
Shear: -2107 lb 4295 lb
37/43
Project:Gravity Calcs ; ; StruCalc 9.0 page
Location:DBM-1 +,
Uniformly Loaded Floor Beam o/
[2015 International Building Code(2015 NDS)]
5.5 IN x 9.5 IN x 6.0 FT Pressure Treated
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:17 PM
Section Adequate By:742.3%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.00 IN L/MAX
Dead Load 0.00 in
Total Load 0.01 IN L/9413
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A
Live Load 240 lb 240 lb
Dead Load 142 lb 142 lb
Total Load 382 lb 382 lb
Bearing Length 0.11 in 0.11 in
BEAM DATA Center
Span Length 6 ft
Unbraced Length-Top 0 ft 6ft
Floor Duration Factor 1.00 AAA
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 875 psi Fb'= 700 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.00 Ci=0.80 Floor Tributary Width FTW= 2 ft 0 ft
Shear Stress: Fv= 170 psi Fv'= 136 psi
Cd=1.00 Ci=0.80 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1300 ksi E'= 1235 ksi BEAM LOADING
Ci=0.95 Beam Total Live Load: wL= 80 plf
Comp.1-to Grain: Fc-L= 625 psi Fc--- = 625 psi Beam Total Dead Load: wD= 36 plf
Controlling Moment: 573 ft-lb Beam Self Weight: BSW= 11 plf
3.0 ft from left support Total Maximum Load: wT= 127 plf
Created by combining all dead and live loads.
Controlling Shear: -382 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 9.82 in3 82.73 in3
Area(Shear): 4.21 in2 52.25 in2
Moment of Inertia(deflection): 10.02 in4 392.96 in4
Moment: 573 ft-lb 4826 ft-lb
Shear: -382 lb 4737 lb
38/43
Project:Gravity Calcs StruCalc 9.0 page
/ .>
Location:GBM-1
Uniformly Loaded Floor Beam or
[2015 International Building Code(2015 NDS)] = -
5.5 IN x 12.0 IN x 14.5 FT
24F-V4-Visually Graded Western Species-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:17 PM
Section Adequate By:30.7%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.36 IN U480
Dead Load 0.17 in
Total Load 0.54 IN 11325
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:L/240
REACTIONS A
Live Load 3770 lb 3770 lb
Dead Load 1800 lb 1800 lb
Total Load 5570 lb 5570 lb
Bearing Length 1.56 in 1.56 in
BEAM DATA Center
Span Length 14.5 ft
Unbraced Length-Top 0 ft 14.5 ft
Floor Duration Factor 1.00
Camber Adj.Factor 1.5
Camber Required 0.26 FLOOR LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Floor Live Load FLL= 40 psf 0 psf
24F-V4-Visually Graded Western Species Floor Dead Load FDL= 18 psf 0 psf
Base Values Adjusted Floor Tributary Width FTW= 13 ft 0 ft
Bending Stress: Fb= 2400 psi Controlled by:
Fbcmpr= 1850 psi Fb'= 2400 psi Wall Load WALL= 0 plf
Cd—=1.00 BEAM LOADING
Shear Stress: Fv= 265 psi Fv'= 265 psi Beam Total Live Load: wL= 520 plf
Cd=1.00 Beam Total Dead Load: wD= 234 plf
Modulus of Elasticity: E= 1800 ksi E'= 1800 ksi Beam Self Weight: BSW= 14 plf
Comp.--to Grain: Fc- = 650 psi Fc- = 650 psi Total Maximum Load: wT= 768 plf
Controlling Moment: 20192 ft-lb
7.25 ft from left support
Created by combining all dead and live loads.
Controlling Shear: 5570 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Req'd Provided
Section Modulus: 100.96 in3 132 in3
Area(Shear): 31.53 in2 66 in2
Moment of Inertia(deflection): 594.39 in4 792 in4
Moment: 20192 ft-lb 26400 ft-lb
Shear: 5570 lb 11660 lb
39/43
Project:Gravity Calcs ,/ StruCalc 9.0 page
Location:MBM-4
Combination Roof And Floor Beam of
[2015 International Building Code(2015 NDS)] u" '
3.5 IN x 11.875 IN x 5.0 FT
2.0 Rigidlam LVL-Roseburg Forest Products StruCalc Version 10.0.1.5 1/23/2018 6:21:18 PM
Section Adequate By:231.7%
Controlling Factor:Shear
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.01 IN L/6101
Dead Load 0.01 in
Total Load 0.02 IN L/3982
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:U240
REACTIONS A
Live Load 1819 lb 1627 lb
Dead Load 968 lb 866 lb
Total Load 2787 lb 2493 lb
Bearing Length 1.06 in 0.95 in
BEAM DATA Center
Span Length 5 ft
Unbraced Length-Top 0 ft 5 ft
Roof Pitch 4 :12
Floor Duration Factor 1.00
Roof Duration Factor 1.15 ROOF LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Roof Live Load RLL= 25 psf 0 psf
2.0 Rigidlam LVL-Roseburg Forest Products Roof Dead Load RDL= 15 psf 0 psf
Base Values Adjusted Roof Tributary Width RTW= 9 ft 0 ft
Bending Stress: Fb= 3100 psi Fb'= 3570 psi
Cd=1.15 CF=1.00 FLOOR LOADING
Shear Stress: Fv= 290 psi Fv'= 334 psi Side 1 Side 2
Cd=1.15 Floor Live Load FLL= 40 psf 0 psf
Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Floor Dead Load FDL= 18 psf 0 psf
Comp.--to Grain: Fc- L= 750 psi Fc---'= 750 psi Floor Tributary Width FTW= 10 ft 0 ft
Controlling Moment: 3243 ft-lb Wall Load WALL= 0 plf
2.5 ft from left support BEAM LOADING
Created by combining all dead and live loads. Roof Uniform Live Load: wL-roof= 225 plf
Controlling Shear: 2786 lb Roof Uniform Dead Load: wD-roof= 142 plf
At support. Floor Uniform Live Load: wL-floor= 400 plf
Created by combining all dead and live loads. Floor Uniform Dead Load: wD-floor= 180 plf
Beam Self Weight: BSW= 10 plf
Comparisons with required sections: Req'd Provided Combined Uniform Live Load: wL= 625 plf
Section Modulus: 10.9 in3 82.26 in3 Combined Uniform Dead Load: wD= 333 plf
Area(Shear). 12.53 in2 41.56 in2 Combined Uniform Total Load: wT= 958 plf
Moment of Inertia(deflection): 29.44 in4 488.41 in4
Moment: 3243 ft-lb 24470 ft-lb POINT LOADS-CENTER SPAN
Shear: 2786 lb 9241 lb Load Number One
Live Load 320 lb
Dead Load 170 lb
Location 1 ft
*Load obtained from Load Tracker.See Summary Report for details.
40/43
Project:Gravity Calcs frr StruCalc 9.0 page
Location:MBM-3(2) i ' z.
Multi-Loaded Multi-Span Beam of
[2015 International Building Code(2015 NDS)] --
5.25 IN x 11.875 IN x 17.0 FT -
5.25INx11.875INx17.0FT
2.0 Rigidlam LVL-Roseburg Forest Products StruCalc Version 10.0.1.5 1/23/2018 6:21:18 PM
Section Adequate By:7.8%
Controlling Factor:Deflection
PEFLECTIONS Center LOADING DIAGRAM
Live Load 0.49 IN U416
Dead Load 0.30 in
Total Load 0.79 IN L/259
Live Load Deflection Criteria:L/360 Total Load Deflection Criteria:L/240 1
2
REACTIONS A B
Live Load 3902 lb 3878 lb
Dead Load 2352 lb 2334 lb 0 M111415f6;
fr q,,
ll
Total Load 6254 lb 6212 lb
Bearing Length 1.59 in 1.58 in
w
BEAM DATA Center
Span Length 17 ft
Unbraced Length-Top 0 ft
Unbraced Length-Bottom 17 ftlillillil
Live Load Duration Factor 1.00
Notch Depth 0.00 UNIFORM LOADS Center
MATERIAL PROPERTIES Uniform Live Load 120 plf
2.0 Rigidlam LVL-Roseburg Forest Products Uniform Dead Load 54 plf
Base Values Adjusted Beam Self Weight 16 plf
Bending Stress: Fb= 3100 psi Fb'= 3104 psi Total Uniform Load 190 plf
Cd=1.00 CF=1.00 POINT LOADS-CENTER SPAN
Shear Stress: Fv= 290 psi Fv'= 290 psi Load Number One * Two
Cd=1.00 Live Load 2050 lb 2050 lb
Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Dead Load 1299 lb 1299 lb
Comp.i to Grain: Fc-i= 750 psi Fc-1'= 750 psi Location 3.25 ft 13.5 ft
Controlling Moment: 20314 ft-lb *Load obtained from Load Tracker.See Summary Report for details.
8.84 Ft from left support of span 2(Center Span) TRAPEZOIDAL LOADS-CENTER SPAN
Created by combining all dead loads and live loads on span(s)2 Load Number One Two Three Four
Controlling Shear: 6254 lb Left Live Load 163 plf 80 plf 163 plf 80 plf
At left support of span 2(Center Span) Left Dead Load 98 plf 36 plf 98 plf 36 plf
Created by combining all dead loads and live loads on span(s)2 Right Live Load 163 plf 80 plf 163 plf 80 plf
Right Dead Load 98 plf 36 plf 98 plf 36 plf
Comparisons with required sections: Req'd Provided Load Start 0 ft 0 ft 13.5 ft 13.5 ft
Section Modulus: 78.53 in3 123.39 in3 Load End 3.25 ft 3.25 ft 17 ft 17 ft
Area(Shear): 32.35 in2 62.34 in2 Load Length 3.25 ft 3.25 ft 3.5 ft 3.5 ft
Moment of Inertia(deflection): 679.47 in4 732.62 in4
Moment: 20314 ft-lb 31917 ft-lb
Shear: 6254 lb 12053 lb
41/43
Project:Gravity Calcs F' StruCalc 9.0 page
*1 •
Location:MBM-3 y7 y,.
Combination Roof And Floor Beam of
[2015 International Building Code(2015 NDS)] -
5.25 IN x 11.875 IN x 16.5 FT
2.0 Rigidlam LVL-Roseburg Forest Products StruCalc Version 10.0.1.5 1/23/2018 6:21:19 PM
Section Adequate By:22.6%
Controlling Factor:Deflection
PEFLECTIONS Center LOADING DIAGRAM
Live Load 0.43 IN U464
Dead Load 0.25 in
Total Load 0.67 IN L/294
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:L/240
REACTIONS A B
Live Load 3094 lb 3094 lb
Dead Load 1784 lb 1784 lb
Total Load 4878 lb 4878 lb
Bearing Length 1.24 in 1.24 in
BEAM DATA Center
Span Length 16.5 ft
Unbraced Length-Top 0 ft 16.5 ft
Roof Pitch 4 :12
Floor Duration Factor 1.00
Roof Duration Factor 1.15 ROOF LOADING
Notch Depth 0.00
Side 1 Side 2
MATERIAL PROPERTIES Roof Live Load RLL= 25 psf 0 psf
2.0 Rigidlam LVL-Roseburg Forest Products Roof Dead Load RDL= 15 psf 0 psf
Base Values Adjusted Roof Tributary Width RTW= 7 ft 0 ft
Bending Stress: Fb= 3100 psi Fb'= 3570 psi
Cd=1.15 CF=1.00 FLOOR LOADING
Shear Stress: Fv= 290 psi Fv'= 334 psi Side 1 Side 2
Cd=1.15 Floor Live Load FLL= 40 psf 0 psf
Modulus of Elasticity: E= 2000 ksi E'= 2000 ksi Floor Dead Load FDL= 18 psf 0 psf
Comp. L to Grain: Fc- L= 750 psi Fc-1'= 750 psi Floor Tributary Width FTW= 5 ft 0 ft
Controlling Moment: 20122 ft-lb Wall Load WALL= 0 plf
8.25 ft from left support BEAM LOADING
Created by combining all dead and live loads. Roof Uniform Live Load: wL-roof= 175 plf
Controlling Shear: 4878 lb Roof Uniform Dead Load: wD-roof= 111 plf
At support. Floor Uniform Live Load: wL-floor= 200 plf
Created by combining all dead and live loads. Floor Uniform Dead Load: wD-floor= 90 plf
Beam Self Weight: BSW= 16 plf
Comparisons with required sections: Req'd Provided Combined Uniform Live Load: wL= 375 plf
Section Modulus: 67.64 in3 123.39 in3 Combined Uniform Dead Load: wD= 216 plf
Area(Shear): 21.94 in2 62.34 in2 Combined Uniform Total Load: wT= 591 plf
Moment of Inertia(deflection): 597.51 in4 732.62 in4
Moment: 20122 ft-lb 36705 ft-lb
Shear: 4878 lb 13861 lb
42/43
Project:Gravity Calcs StruCalc 9.0 page
/.r
Location:MFB-1
Uniformly Loaded Floor Beam or
[2015 International Building Code(2015 NDS)]
3.5 IN x 7.25 IN x 8.0 FT
#2-Douglas-Fir-Larch-Dry Use StruCalc Version 10.0.1.5 1/23/2018 6:21:19 PM
Section Adequate By:133.0%
Controlling Factor:Moment
DEFLECTIONS Center LOADING DIAGRAM
Live Load 0.06 IN L/1735
Dead Load 0.03 in
Total Load 0.08 IN U1155
Live Load Deflection Criteria:U360 Total Load Deflection Criteria:L/240
REACTIONSa A
Live Load 427 lb 427 lb
Dead Load 214 lb 214 lb
Total Load 641 lb 641 lb
Bearing Length 0.29 in 0.29 in
BEAM DATA Center
Span Length 8 ft .�
Unbraced Length-Top 0 ft 8ft
Floor Duration Factor 1.00
Notch Depth 0.00
MATERIAL PROPERTIES FLOOR LOADING
#2-Douglas-Fir-Larch Side 1 Side 2
Base Values Adjusted Floor Live Load FLL= 40 psf 0 psf
Bending Stress: Fb= 900 psi Fb'= 1170 psi Floor Dead Load FDL= 18 psf 0 psf
Cd=1.00 CF=1.30 Floor Tributary Width FTW= 2.7 ft 0 ft
Shear Stress: Fv= 180 psi Fv'= 180 psi
Cd=1.00 Wall Load WALL= 0 plf
Modulus of Elasticity: E= 1600 ksi E'= 1600 ksi BEAM LOADING
Comp.-1-to Grain: Fc- L= 625 psi Fc--i'= 625 psi Beam Total Live Load: wL= 107 plf
Controlling Moment: 1283 ft-lb Beam Total Dead Load: wD= 48 plf
Beam Self Weight: BSW= 6 plf
4.0 ft from left support Total Maximum Load: wT= 160 plf
Created by combining all dead and live loads.
Controlling Shear: -641 lb
At support.
Created by combining all dead and live loads.
Comparisons with required sections: Read Provided
Section Modulus: 13.16 in3 30.66 in3
Area(Shear): 5.35 in2 25.38 in2
Moment of Inertia(deflection): 23.09 in4 111.15 in4
Moment: 1283 ft-lb 2989 ft-lb
Shear: -641 lb 3045 lb
43/43
1-29-18
Roseburg y 12:01 pm
1# r si P v[FOGS Cantil tns 1 of 1
CS Beam 2016.11.3.1
km B ea m Engine 2016.9.013
Materials Database 1558
Member Data
Description:MAIN FLOOR Member Type: Joist Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: U480 live, U360 total
Dead Load: 12 PSF Deck Connection: Glued& Nailed
Filename: BeamI
f
13 812 8 5 12
/ 1
2228
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 388# --
2 13' 8.750" Wall DFL Plate(625psi) 3.500" 3.500" 983# --
3 22' 2.500" Wall DFL Plate(625psi) 1.750" 1.750" 237# -51#
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Live Dead
1 301#(226plf) 86#(65p1f)
2 757#{567p11) 227#(170p1f)
3 203#(152p)) 35#(26p11)
Design spans
13' 4.125" 8' 4.875"
Product: 11 7/8" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is requited at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1081.'# 3640.'# 29% 5.72' Odd Spans D+L
Negative Moment 1183.'# 3640.'# 32% 13.73' Total Load D+L
Shear 551.# 1420.# 38% 13.72' Total Load D+L
End Reaction 388.# 1420.# 27% 0' Odd Spans D+L
Int.Reaction 983.# 1935.# 50% 13.73' Total Load D+L
TL Deflection 0.1015" 0.4448" 1J999+ 6.39' Odd Spans D+L
LL Deflection 0.0806" 0.3336" 0999+ 6.39' Odd Spans L
Control: Max Int.React.
DOLs: Live=100% Snow=115d/o Roof=125% Wind=160%
SIMPSON Atpmdcclnamesaetrademaksoftneirespectiveowners Eric Duncan
0.45 Copyright(C)2016 by Simpson Strong-Tie Company Inc ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS
BEAVERTON,OREGON 97005
"Passing is deflnad aswhen the member.IloorjoiE,beam or girder shown on ails drawing meets applicable desgn criteria for Loads,Loading Conditions,and Spans listen on this 5�3-7g3- 68
sheet.The dedgn mud be reviewed by a qualified designer or design pmfa Wonal aomrlrired for approval.This design asrames pmdcet in#allatlon according to the manufacturer's
specifications.
� i-29-I8
lRoseburg
:L Forest Products C:ornparn 1 of I
CS Beam 2016.11-3.1
IanBeam Engine 2016.9.0.3
Materials Database 1558
Member Data
Description:MAIN FLOOR Member Type: Joist Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: 0480 live, U360 total
Dead Load: 12 PSF Deck Connection: Glued& Nailed
Filename: BeamI
•y 2
13 9 12
13 9 12
Bearings and Reactions
Input fiArt Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 549#
2 13' 9.750" Wall DFL Plate(625psil 3.500" 1.750" 549#
Maximum Load Case Reactions
Used for applying point loads(or line,loads)to carrying members
Live Dead
1 423#(284p1f) 127#(79p1f)
2 423#(264plf) 127#(79p!f)
Design spans
13' 2.500"
Product: 11 7/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 1814.'# 3640.'# 49% 6.99' Total Load D+L
Shear 549.# 1420.# 38% 0' Total Load D+L
End Reaction 549.# 1316.# 41% 13.81' Total Load D+L
TL Deflection 0.1865" 0.4403" U850 6.99' Total Load D+L
LL Deflection 0.1434' 0.3302" U999+ 6.99' Total Load L
Control: Pos.Moment
DOLS: Live=100% Snow=115% Roof=12S% Wind=160e/0
IP/1PS{)N Al productna esaretademar softheirn pecllveownes Eric Duncan
PACIFIC LUMBER&TRUSS
-�„ Copyright(C)2016 by Simpson Strong-11e Company Inc ALL RIGHTS RESERVED. BEAVERTON,OREGON 97005
"Pasarg is defined as when the member,flooriotst,beam or g.roer shown on this draw.ng meets applicable design criteria for Loads,Loading Conditions and Spans listed oh this 503-7938368
sheet.The design must be reviewed by a qualified designer or design professional as requ'.red for approval.This design assumes product installation according to the manufacturer's
a sa Roseburg 3 1-29-18
12:Oopm
A Forest Products Company1 of 1
CS Beam 201611 3.I
lanBeamEngine 2016.9 0.3
Materials Database 1558
Member Data
Description:MAIN FLOOR Member Type: Joist Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/480 live, L/360 total
Dead Load: 12 PSF Deck Connection: Glued& Nailed
Filename: Beam1
p 2011 8
I
20 11 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 714# --
2 20'11.500" Wall DFL Plate(625psi) 2.750" 1.750" 714# --
Maximum Load Case Reactions
Used forappfying point loads(online loads)to carrying members
Live Dead
1 5491(412p1f) 185#(124p10
2 549#(412oIf) 165#(124p1f)
Design spans
20 7.000"
Product: DBL 11 7/8" RFPI-400 16.0" O.C. PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 3672.'# 8630.'# 42% 10.51' Total Load D+L
Shear 714.# 2960.# 24% 0' Total Load D+L
End Reaction 714.# 2482.# 28% 20.96' Total Load D+L
TL Deflection 0.4044" 0.6861' L/610 10.51' Total Load D+L
LL Deflection 0.3111" 0.5146" L/794 10.51' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow 115% Roof=125% Wind=160%
SIMPSO Ali product names are trademadisoftt�ir mspective owners Eric Duncan
PACIFIC LUMBER&TRUSS
Copydrt(C)2016 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED BEAVERTON,OREGON 97005
^r annng isdeaned ae when lire member,floor(not loam or girdar shown on this drawing meatsapplicable deagn cdteda tar.00d,Loading Conditions,and Spanslided on this 503'793-8368
fieal.the aeagn mus oe nwarvreo or a quairbad dusignar or dadgn pmfearonal as roqutled tar approval.Thls deagn aawmea Dtoducl Inaellelion according to the manufactumr a
speclgcntions
: �+ 5°1.
� 1-24-18
b s,Roseburg 11:44anl,
��.. "1 forest Products Carnlzini
1 oft
CS Ream 2016.113.1
lmrDeamEnginc 2016.9.0.3
Materials Database 1558
Member Data
Description:UPPER FLOOR Member Type: Joist Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: U480 live, L/360 total
Dead Load: 12 PSF Deck Connection: Glued& Nailed
Filename: Beam1
r
16 5 8
fQ
16 5 8
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 666#
2 16' 5.500" Wall DFL Plate(625psi) 1,750" 1.750" 666#
Maximum Load Case Reactions
Used for applying point loads(or line loads)to carrying members
Live Dead
1 51210200f) 154#(96p1f)
2 512#(320plf) 154#(96pIt)
Design spans
16' 0.000"
Product: 11 7/8" RFPI-20 19.2" O.C. PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2662.`# 3640.'# 73% 8.39' Total Load D+L
Shear 666.# 1420.# 46% 0' Total Load D+L
End Reaction 666.# 950.# 70% 16.46' Total Load D+L
TL Deflection 0.3821" 0.5333' L/502 8.39' Total Load D+L
LL Deflection 0.2940" 0.4000" L/653 8.39' Total Load L
Control: LL Deflection
DOLs: Live=100% Snow=115% Roof=125% Wind=160%
SIMPSON All product names are trademarks of their respective owners Eric Duncan
Sixtmerie
Copyright(C)2016 by Simpson Strong-Tie Company Inc ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSSBEAVERTON,OREGON 97005
"Passing is defined as when the member,11ooryoist,beam or dirties shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this 503.793-8.36.8
sheet.The deign must be reviewed by a qualified designer or design professional as;equated for approval,This deagn assumes product installation according to the manufacturers
Weal ficatiens.
Roseburg 1-29-18
r1 Furst Pnxiucts Crmpum 1 of 1
CS Beam 2016.11.3.1
IanBeamEng ne 2016 903
Materials Database 15511
Member Data
Description:UPPER FLOOR Member Type: Joist Application: Floor
Top Lateral Bracing: Continuous
Bottom Lateral Bracing: Continuous
Standard Load: Moisture Condition: Dry Building Code: IBC/IRC
Live Load: 40 PSF Deflection Criteria: L/480 live, U360 total
Dead Load: 12 PSF Deck Connection: Glued & Nailed
Filename: Beam1
17 1 4
17 1 4
Bearings and Reactions
Input Min Gravity Gravity
Location Type Material Length Required Reaction Uplift
1 0' 0.000" Wall DFL Plate(625psi) 5.500" 1.750" 577#
2 17' 1.250" Wall DFL Plate(625psi) 1.750" 1.750" 577#
Maximum Load Case Reactions
Used for applying point loads(or Una loads)to canying members
Live Dead
1 444#(333plf) 133#(100plf)
2 444#(333p1f) 133#(100p1f)
Design spans
16' 7.750"
Product: 11 7/8" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS
Design assumes continuous lateral bracing along the top chord.
Design assumes continuous lateral bracing along the bottom chord.
Lateral support is required at each bearing.
Allowable Stress Design
Actual Allowable Capacity Location Loading
Positive Moment 2401.'# 3640.'# 65% 8.71' Total Load D+L
Shear 577.# 1420.# 40% 0' Total Load D+L
End Reaction 577.# 950.# 60% 17.1' Total Load D+L
TL Deflection 0.3785" 0.5549" U527 8.71' Total Load D+L
LL Deflection 0.2912" 0.4161" L/686 8.71' Total Load L
Control: LL Deflection
DOLs: Live=100% $now=115% Roof=125% Wind=160%
SIMPSON A.l product names are trademarks of ten respective owners Eric Duncan
PACIFIC LUMBER&TRUSS
Copyright(C)2016 by Simpson Strong•Tte Company Inc.ALL RIGHTS RESERVED. BEAVERTON,OREGON 97005
s
"Passing is defined aswhen the member,floor Joist.beam or girder,shown on thisdrawing meats applicable design criteria for Loads,Loading Conditions,and Spans tided on this 503.793-8368