Permit (165) INCITY OF TIGARD MECHANICAL PERMIT 2. COMMUNITY DEVELOPMENT Permit#: MEC2019-00182 T rGARD 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439 Date Issued: 05/02/2019 Parcel: 2S 102AA04100 Jurisdiction: Tigard Site address: 12230 SW MAIN ST 120 Project: Wags Pet Resort Subdivision: None Lot: None Project Description: Installing new ducting for existing RTU,ducting for existing exhaust fan,new evap cooler with ducting,new duct detector,and CO2 sensors for existing RTU. Contractor: WATTS HEATING&COOLING INC Owner: HOBO PROPERTIES LLC 580 PORTLAND AVE. PO BOX 8087 GLADSTONE, OR 97027 PORTLAND, OR 97280 PHONE: 503-786-2858 PHONE: FAX: 503-786-2807 FEES Specifics: Description Date Amount Type of Use: COM Permit Fee 05/02/2019 $347.71 Class of Work: ALT Type of Const: VB Plan Review 05/02/2019 $86.93 Occupancy Grp: B Occupancy Load: 12%State Surcharge-Mechanical 05/02/2019 $41.73 Stories: Info Process/Archiving-Sm$0.50(up to 05/02/2019 $1.50 11x17) Project Valuation: $10,000.00 Fuel Air Handlers Fuel Types: Electricity Units<10000 cfm: Gas Pressure: Units> 10000 cfm: Furnaces Boilers&Compressors Furnaces< 100K BTU: 0-3 HP: Furnaces>= 100K BTU: 3-15 HP: Floor Furnaces: 15-30 HP: Unit Heaters: 30-50 HP: Vents w/o Appliances: 50 or Greater HP: Air Conditioning: Heat Pump: Appliances Vent Fans: Vent Systems: Total $477.87 Hoods: Comm Incinerators: Required Items and Reports(Conditions) Woodstoves: Gas Fireplaces: Clothes Dryers: Other Mech Units: Gas Outlets: Other Desc: evap cooler Duct Work: 1 Fire/Smoke Dampers: This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180 days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR 952-001-0010 through OAR 952-001-0090. You may obtain a copy of the rules or direct questions to OUNC by calling 503.232.1987 o --- .1�i ►'��tI1 Issued By: ., Call 513.639.4175 by 7:00 a.m.for the next available inspection da,,. This permit card shall be kept in a conspicuous place on the job site until completion of the project. Approved plans are required on the job site at the time of each inspection. Mechanical Permit Applicai n - FOR OFFICE USE ONLY City of Tigard ha n R 2 1"" 2019 Received 2 ! ��� IN �� g i'�I t�i', ,, 1S i Date/By: 5 ! 9 ,��/ yerk.15--o/O: 13125 SW Hall Blvd.,Ti ard,OR 97223Phone: 503.718.2439 Fax: 503.598 1q60 PDate/Bevtew 9. 3 - 1a ! T a�/ 0 62... . y: T I GARD Inspection Line: 503.639.4175 ` „ Date Ready/By: y �J Juris: RI See Page 2 for Internet: www.tigard-or.govfutified/Method:(I v G '`, Supplemental Information z11- _ a a l*S a ,it' ® =I l ;W A,: .,,u i.,Iol -... ` _ .....,.. '-- ` -ZAddition'-"'''Addition/alteration/replacement`-�' Mechanical permit fees*are based on the value of the work El New construction performed.Indicate the value(rounded to the nearest dollar)of all ❑Demolition 0 Other: mechanical materials,equipment,labor,overhead,and profit. • Value:$10,000, l ; .1GOOR s t , ,. . , S ❑ 1-and 2-family dwelling ®Commercial/industrial 0 Accessory building For special information use checklist. ❑Multi-family 0 Master builder 0 Other: Description Qty. Ea. Total 1:,ollivIEFA Heating/cooling: Air conditioning 46.75 Job site address:12230 SW Main St Furnace 100,000 BTU(ducts/vents) 46.75 City/State/ZIP:Tigard,OR 97223 Furnace 100,000+BTU(ducts/vents) 54.91 j�� n Heat pump 61.06 Suite/bldg./apt.no.: Project name:t V 4�. /' 1 p cs 7V 7 Duct work 23.32 Cross street/directions to job site: Hydronic hot water system 23.32 Residential boiler(radiator or hydronic) 23.32 Unit heaters(fuel-type,not electric), in-wall,in-duct,suspended,etc. 46.75 Flue/vent for any of above 23.32 Other: 23.32 Subdivision: Lot no.: Other fuel appliances: Tax map/parcel no.: Water heater 23.32 l .. `:::644, '' a W Gas fireplace/insert 33.39 i i... X11 _..,. 1 TIO l 1 ® P "'s "" '`' Flue vent for water heater or gas install new ducting for existing RTU,install new ducting for existing Exhaust fireplace 23.32 Fan,Install new evacp cooler with ducting,install new duct detector and CO2 Log lighter(gas) 23.32 Wood/pellet stove 33.39 sensors for existing RTU Wood fireplace/insert 23.32 Chimney/liner/flue/vent 23.32 Other: 23.32 ` :64.70 " «tg '- v- Environmental exhaust and ventilation: Name:Wags Pet Resort Range hood/other kitchen equipment 33.39 Address: 12230 SW Main St. Clothes dryer exhaust 33.39 City/State/ZIP:Tigard,OR 97223 Single-duct exhaust(bathrooms, toilet compartments,utility rooms) 23.32 Phone:(503-3) Fax:( ) Attic/crawlspace fans 23.32 1 ® ; 1P�UI 1 CoN A `: ,ER"sO23.32 r.7_=. . _., >_r ,... ,,i« ...,. max.,. _,-.. ��r. ...; Other: Business name:Watts Heating&Cooling,Inc. Fuel piping: $14.15 for first four;$4.03 for each additional Contact name:Loren Watts Furnace,etc. Address:580 Portland Ave Gas heat pump Wall/suspended/unit heater City/State/ZIP:Gladstone,OR 97027 Water heater Phone:(503)786-2858 Fax::( ) Fireplace Range E-mail:loren@wattsheating.com Barbecue :':;17 3. li . . ,. - : - .. i ... , :ellpvi Clothes dryer(gas) Business name:Watts Heating&Cooling,Inc. Other Address:580 Portland Ave Subtotal City/State/ZIP:Gladstone,OR 97027 Minimum permit fee($90.00) Plan review(25%of permit fee) Phone:(503)786-2858 Fax:( ) State surcharge(12%of permit fee) CCB lic.:134602 !i 42-3 /�l TOTAL PERMIT FEE This permit application expires if a permit is not obtained within 180 days after it has been accepted as complete. Authorized signature: * Fee methodology set by Tri-County Building Industry Service Board Print name:Loren Watts Date:3/22/19 I:\Building\Permits\MEC PermitApp_040113.doc 440-4617T(1 1/02/COM/WEB) Mechanical Permit Application - City of Tigard Page 2 - Supplemental Information Commercial & Multi-Famil Fee Schedule: $0.00 to$500.00 Minimum fee$69.06 $500.01 to$5,000.00 $69.06 for the first$500.00 and $3.07 for each additional$100.00 or fraction thereof,to and including $5,000.00. $5,000.01 to$10,000.00 $207.21 for the first$5,000.00 and $2.81 for each additional$100.00 or fraction thereof,to and including $10,000.00. $10,000.01 to$50,000.00 $347.71 for the first$10,000.00 and $2.54 for each additional$100.00 or fraction thereof,to and including $50,000.00. $50,000.01 to$100,000.00 $1,363.71 for the first$50,000.00 and $2.49 for each additional$100.00 or fraction thereof,to and including $100,000.00. $100,000.01 and up $2,608.71 for the first$100,000.00 and $2.92 for each additional$100.00 or fraction thereof. Note: All new commercial buildings require 2 sets of plans. I:\Building\Permits\MEC_PermitApp_040113.doc 2 City of Tigard Tel: 503.718.2439 Location: Inspection Date: 12230 SW MAIN ST 120, TIGARD, OR, 97223 May 9, 2019 at 12:30:00 PM Record Type: Record ID: Commercial - Mechanical MEC2019-00182 Inspection Type: Inspector: 699 Mechanical final Chip Barnett Result: PASS - NoCofO Comments: Violation Summary: Inspector Contractor