Loading...
Report (44) EV\-) c\ \ -� Page Number of REZHOR® Power Vented, Low Static Axial Fan Model UDAP Commercial/Industrial Unit Heaters RECEIVED APR 18 2019 Sizes 30-125 carry an additional approval I�� � IARD for use in residential garage/workshops under CSA International Requirement BUILDING DIVISION 10.96-U.S.and CR96-0005-Canada it CcQS CSA 2.6b ANSI Z83.8b DESCRIPTION Reznor®V3 Series Model UDAP gas-fired unit heaters are available in 14 sizes ranging from 30,000 to 400,000 BTUH gas input All sizes are approved for commerciaUndustrial installations.Sizes 30-125 carry an additional approval for use in attached residential garage/workshop application.Model UDAP heaters are designed for 82-83%thermal efficiency and are approved for installation in the United States and Canada by the Canadian Standards Association(CSA). Reznor V3 Series unit heaters have a refreshing new appearance with a glossy white cabinet finish and less visible hardware.Each size cabinet is easily suspended from either 2 or 4 suspension points.Or,an optional hanger kit for Sizes 30-125 allows for ceiling mounting.The low voltage terminal strip on the outside of the ag cabinet makes connecting control wiring easy with no panels to remove.The addition of a'G'terminal to the strip,along with the new design of the circuit board,allows for fan only operation(without adding relays).All units have a factory installed gas line nipple to the exterior of the cabinet for easy gas service connection. The preeminent new internal feature is the TcoRE2 heat exchanger and single burner combustion system.Other standard features include a single-stage gas valve,multi-try direct spark ignition with timed lockout,pressure switch to verify vent flow, resiliently isolated venter motor, venter wheel with improved housing, resiliently isolated axial fan and motor assembly,and a high temperature limit control.Sizes 30-125 also include a flame rollout safety switch.Operation is controlled through an integrated circuit board.The circuit board monitors heater operation and has LED diagnostic indicator lights to identify abnormalities in control functions. The V3 Series unit heaters are designed to provide all the features you expect in a Reznor heater plus im- proved efficiency,easier installation,and a new look-both inside and out Look for the unique white unit with no visible front and bottom hardware,deep red louvers,black side handle,and angled corner to know you have a genuine Reznor heater. STANDARD FEATURES • Sizes 30-400 certified for commercial/industrial heating application • Sizes 30-125 carry an additional approval for use in residential garage/workshop heating applications • 82-83%Thermal efficient-TOP in its class! • 50-60°F Rise range • TcorE2 titanium stabilized aluminized steel heat exchanger • Patented A single burner combustion system including a one-piece burner assembly • 115/1/60 Supply voltage • 115 Volt open fan motor with internal overload protection • Transformer for 24-volt controls • Integrated circuit board with diagnostic indicator lights • Multi-try direct spark ignition with timed lockout • Fan relay(included on the circuit board) • Single-stage natural gas valve(field adjustable for operation to 9,000 ft.elevation a) • Vibration/noise isolated fan and venter motors-designed for low noise operation • 2-pt and 4-pt Suspension-standard on all sizes • External terminal strip for 24-volt wiring • External gas connection • Full fan guard-engineered for safety • Improved cabinet design with less visible hardware OPTIONAL FEATURES - • Single-stage,propane gas valve(field adjustaLle for operation to 9,000 ft.elevation 8) FACTORY INSTALLED • Two-stage natural gas or propane gas valve-Sizes 60-400 • 409 or 316 Stainless steel heat exchangers • Totally enclosed fan motor(Sizes 30-250,11W only) • Common venting with other gravity vented Category I appliance(s)(Sizes 30-100) 'U.S.Patent No.6,889,686. a Pressure switch change required for installations above 6,000 ft. Form RZ-C-UH(Version H)Page 8 tow Page Number of OPTIONAL FEATURES - • Vent cap FIELD INSTALLED • Thermostat • Thermostat guard with locking cover • Vertical louvers • Downturn nozzle kits • Gas conversion kits(natural and propane) • Primary/secondary controls for zoning up to six units • Ceiling suspension kit-Sizes 30-125 • Hanger kits for V pipe • Stepdown transformer(for 208/115,230/115 or 460/115 supply voltage) • Manual shutoff valves TECHNICAL DATA Model UDAP Size 30 45 60 75 100 125 150 175 200 225 250 300 350 400 Input Heating Capacity BTUH 30,000 45,000 60,000 75,000 105,000 120,000 150,000 175,000 200,000 225,000 250,000 300,000 350,000 400,000 kw/h 8.8 13.2 17.6 22.0 30.8 35.2 43.9 51.2 58.6 65.9 73.2 87.8 102.5 117.1 Thermal Efficiency(%) 82 " 83 83 83 83 83 83 83 83 83 83 83 83 83 Output Heating BTUH 24,600 37,350 49,800 62,250 87,150 99,600 124,500 145,250 166,000 186,750 207,500 249,000 290,500 332,000 Capacity` kw/h 7.2 11.0 146 18.3 25.6 29.2 36.4 42.5 48.6 54.7 60.8 72.9 85.1 97.2 Gas Connection Natural 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 (inches)° Propane 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 Vent Connection Size E(inches 4 4 4 4 4 4 5 5 5 5 5 6 6 6 diameter) Control Amps(24 volt) 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 Full Load Amps(115 volt) 1.9 2.4 2.4 3.3 3.9 5.1 3.8 3.8 4.6 7.5 7.5 11.0 11.0 11.0 Maximum Over Current Protection 15 15 15 15 15 15 15 15 15 15 15 20 F 20 20 Normal Power Consumption 109 155 155 217 276 354 392 392 491 747 747 1086 1086 1086 (mss) . Discharge Air Temperature Rise 50 55 60 60 60 60 60 60 60 60 60 60 60 60 i°F) Air Volume CFM 456 629 769 961 1345 1537 1921 2242 2562 2882 3202 3843 4483 5123 M3/minute 12.9 17.8 21.8 27.5 36.7 45.9 54.4 63.5 72.5 81.6 90.7 108.8 126.9 145.1 Discharge Air Opening ft2 0.96 0.96 1.25 1.25 2.01 2.01 2.56 2.56 2.56 3.51 3.51 4.79 4.79 4.79 Area M2 0.09 0.09 0.12 0.12 0.19 0.19 0.24 0.24 0.24 0.33 0.33 0.45 0.45 0.45 Output Velocity FPM 475 656 616 770 668 763 752 877 1003 820 911 802 936 1069 M/minute 145 200 188 238 196 245 229 267 306 250 278 244 285 326 Fan Motor HP c Open 0.02 0.03 0.03 0.06 1/30 1/20 1/6 1/6 1/6 1/4 1/4 1/2 1/2 1/2 Enclosed 0.06 0.06 0.06 0.06 1/4 1/4 1/4 1/4 1/4 1/4 I 1/4 1/2 1/2 1/2 Fan Motor RPM 1550 1550 1550 1550 1050 1050 1050 1050 1050 1050 1050 1050 1050 1050 Fan Diameter(inches) 10 10 12 12 16 16 18 18 18 20 20 24 24 24 Sound Level dba @ 40 40 40 49 54 55 51 52 53 56 56 59 61 62 Approximate Net lbs 54 59 67 72 96 101 172 187187 203 215 269 294 306 Weight kk 24 - 27 30 33 44 46 78 85 85 92 98 122 133 139 Approximate Ship lbs 61 66 74 79 118 123 204 219 219 245 257 321 346 358 Weight kg 27 30 33 36 54 56 93 100 100 111 117 146 157 163 °CSA rating for altitudes to 2000 R °Size shown is for gas connection to a single stage gas valve,not supply line size. e Smaller or larger vent pipe diameters may be allowed;refer to the Venting Installation Manual,Form I-V-PV.If vent diameter is different from vent connection,reducer/enlargers will be rield.required. °MOP=2.25 x largest motor FLA+remaining load.Answer is rounded down to the next size of commercially available circuit breaker or fuse. °All other information in this table is based on a heater equipped with a standard 115 volt open fan motor. For installations where dirt dust and other air borne contamination is present in the Indoor environment it is recommended to use separated combustion units(Model UDAS).These models use air from outside the space for combustion.This will help reduce the build up of contaminates on the burner which would affect the combus- tion process.Refer to the installation manuals for recommended frequency of maintenance and cleaning. Form RZ-C-UH(Version H)Page 9 • Page Number of DIMENSIONS Model UDAP ±1/16"(2mm) - Size A B C D E F G H J K M N P Q R 30,45 12 1/8 25 5/8 10 13 13/16 26 21 9/16 5 3/16 6 112 2 11/16_ 3 7/8 17 3/8_ 11/16 4 5/16 13 9 9/16 60 15 1/8 25 5/8 13 13 13/16 27 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 75 15 1/8 25 5/8 13 13 13/16 27 5/8 21 9/16 7 7/8 6 1/2 5 1/2 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 100 23 1/8 25 5/8 21 13 13/16 28 5/8 21 9/16 14 1/2_ 6 1/2 _ 8 3/4 3 7/8_ 17 3/8 11/16 4 5/16 13 10 1/2 125 23 1/8 25 5/8 21 13 13/16_ 29 3/8 21 9/16 14 1/2 6 12 8 3/4 3 7/8 17 3/8 11/16 4 5/16 13 10 1/2 150,175, 200 20 1/8 38 3/16 16 23 42 35 3/8 I 8 12 8 1/4 5 7/16 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 16 3/8 225,250 26 1/8 38 3/16 22 23 42 35 3/8 13 1/16 8 13/16 9 6 1/2 25 11/16 1 3/8 8 3/16 22 3/16 15 5/8 300, 34 1/8 41 30 23 42 35 3/8 17 1/16 9 11 13/16 7 5/16 27 11/16 1 3/8 8 3/16 22 3/16 16 3/16 400 Size A B C D E F G H J _ K M N P Q R 30,45 (308) (651) (254) (351) (660) (548) (132) (165) (68) (98) (441) (17) (110) (330) (243) 60 (384) (651) (330) (351) _ (686) (548) (200) (165) (140) (98) (441) (17) (110) (330) (267) 75 (384) (651) (330) (351) (702) (548) _ (200) (165) _ (140) (98) (441) (17) (110) (330) (267) 100 (587) (651) (533) (351) (727) , (548) _ (368) (165) (222) (98) (441) (17) (110) (330) (267) 125 (587) (651) (533) (351) (746) (548) (368) (165) (222) (98) (441) (17) (110) (330) (267) 150,175, (511 200 ) (970) (406) (584) (1,067) (899) (216) (210) (138) (165) (652) (35) (208) (564) (416) 225,250 (664) (970) (559) (584) (1,067) (899) (332) (224) (229) (165) (652) (35) (208) (564) (397) 300,400 350, (867) (1,041) (762) (584) (1,067) (899) (433) (229) (300) (186) (703) (35) (208) (564) (411) N -4 M + R-Hanger - Dimension for 12ptSuspension P • T Combustion Air Inlet PandQ R L Hanger Thermostat • REAR - Dimensions C TOP VIEW t Connection VIEW �.aj.-- ...\ for 4-pt (30-125 Vertical; v -_- __ _ _ 150-400 Horizontal) - - Suspension O •...:: 3/8%16 Female Thread I T _ all suspension points1/4„ •-`�-•••.••. T _--- •..] , i • • / Line Voltage 1,F K External Vent Connection • I I• • Inlet(connects �---H • Gas (see Technical at circuit board) Connection Data for size) k B > c E D I < F .I FRONT 0 RIGHT SIDE lr.........�. VIEW Z VIEW — A C (( _. _ N (Access Panel) i1t ._11 `'. ..7 � I ILLIit .mss — 1 I iiimmummilinimimmii CLEARANCES FROM COMBUSTIBLES Flue Access Non-Access Top Connector Panel' Side Bottom'' Rear'- Size inches mm inches mm inches mm inches mm inches mm inches mm 30-125 1 25 6 152 18 457 1 25 1 25 18 457 150-400 4 102 6 152 18 457 2 51 1 25 18 457 'Access Panel clearance is required for service clearance to controls .Suspend the heater so that the bottom is a minimum of 5'(15M)above the floor. Rear clearance is required for air movement.Rear clearance should be measured from the fan motor Form RZ-C-UH(Version H)Page 10