Loading...
Report (43) (N G`- -CA-1053 - �5 \ \ \,,L) (9L 14 S��'V, SUBMITTAL AC018MNADCH/AA, AC018MXSCCC/AA l Pagelof3 ■.■ Samsung,Low Ambient Cooling,High-Wall Evaporator,Split System www.SamsuPage 1.corn Job Name Centene 3rd Floor Location Purchaser Oregon-Aire Engineer- Submitted to Matt Tidwell Reference I I Approval I v I Construction I Unit Designation CRAC-1 /CRCU-1 Schedule/# OUTPOO6? UNI! 1,.0C 0N. ROCS ,566- M40 i--dCeTION 51;; AO D pe-r.A 1 L ,��,, , Specifications k .-, Model Indoor Unit Model Number AC018MNADCH/AA _.. Outdoor Unit Model Number AC018MXSCCC/AA Nominal Capacity Btu/h 18,000 •Wall-mounted evaporator RECEIVED Performance Capacity Range Btu/h 4,000-20,000 SEER/EER 18.8/9.05 •Low ambient cooling to-40° AHRI Certification Number 10491544 QPR � •The outdoor unit shall supply power to indC4enrt via +f Q 3 power wire Voltage l o/V/Hz 1/208-230/60 Working Voltage Range(VAC) 176-2s4(max.3%deviation from each) •Auto-restart after power loss CITY OF TIGARD Power Operating Current min./std./max. 1.5/8.5/10.5 ���� �� �*Setting to prevent Max.Breaker Amps 15 •The outdoor unit shall have a snow a Min.Circuit Ampacity(A) 13.0 snow drifting against an idle outdoor unit. W X H X D Indoor Unit 35 5/16 X 10 5/16 X 10 5/16 .The indoor unit shall have a removable EEPROM that stores system programming Dimensions (in.) Outdoor Unit 34 5/8 X 25 1/8 X 12 3/16 information,unit name,and other data Weight Indoor Unit 23.81 (lbs.) Outdoor Unit 79.81 •All indoor unit addressing and option settings shall be done digitally;the indoor unit does l Heat Exchanger l Indoor&Outdoor Unit Type Aluminum Fin/Copper Tube I not contain rotary dials or setting switches. Sound Pressure Indoor Unit dB(A) (Silent)/L/M/H 29/32/37/42 .The outdoor unit shall have a night time quiet mode option to reduce operating sound Level Outdoor Unit dB(A) High 48 during the night. Operating Outdoor °F 23 5 T S 115 Construction Temperatures 40 5 T 5 115 whvind baffle The outdoor unit shall be galvanized steel with a baked on powder coated finish for Indoor °F 61 5 T 590 durability Indoor&Outdoor High side(flare) 1/4" Low side(flare) 1/2" i indoor unit chassis simile be UL94 VO with a galvanized steel mounting plate Pipe Connections Maximum(ft.) 98 Maximum Vertical Separation(ft.) 66 The indoor unit shall have easy-access to wire,pipe,and drain connections via access Condensate Connection 11/16"OD panel on front of unit for easier installation and service Type R410A Control Method Electronic Expansion Valve Heat Exchanger Refrigerant Factory Charge oz. 45.85 The indoor unit and outdoor unit heat exchangers shall be mechanically Charged for 25 ft bonded aluminum fin to copper tube Additional Refrigerant 0.11 oz/ft over 25 ft Controls Manufacturer Samsung Control signal shall be a DDC type signal Compressor Type Inverter Driven,BLDC,Rotary RLA 'Amps 9.0 Advanced configuration options for high room temperature alerts using MIM-814 Type BLDC with Crossf ow fan(1) external contact control to enable a backup system and/or to notify a BMS(refer to Evaporator Fan Air Volume l CFM(LIM/H) 265/336/406 technical documents available at www.DVMdownload.com for full details). Output(W)/FLA(A) 27 W/0.70 A Motor DLDC With Axial Type Fan(1) Interconnect control wire between outdoor indoor unit shall be 16AWG X 2 shielded Condenser Fan FLA/W/CFM(max.) 0.9 A/89 W/1,412 CFM Wired or wireless controls must be purchased separately Simplified 1=1 MWR-SHOON Wired Controller Simplified Touch Controller I-1 MWR-SH1ON Connection to optional wired controllers shall be 2 X 16AWG shielded wire Premium w/scheduling =I MWR-WE11 N - Wireless Controller -"t=1 MR-EH000 Controls shall integrate with a BMS system - Wi-Fi Adapter —=MIM H03UN The system shall integrate with the Samsung NASA Controls Solution External Temperature Sensor =MRW-TA Optional External Contact Control O MIM-B14 No additional interface modules/adapters are required when connecting to Samsung Accessories Central Control Interface Module for Connection 0 MIM-N01 NASA DVM S central control options(MIM-DO1AUN,MIM-B17BUN,MIM-B18BUN, to DVM Plus Controls(non-NASA) _ MCM-A300N). Wall Bracket(for outdoor unit) O CKN-250 Wind Baffles Front O WBF-5M Refrigerant System Back =WBB-6M The refrigerant shall be R410A Line Sets-insulated and flared,interconnect 0 25'-ILS2507 cables included p 50'-1135007 The compressor shall be hermetically sealed,inverter controlled,BLOC Rotary Certifications I ETL(UL 1995) Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit Safety Devices:PCB fuses,indoor unit terminal block thermal fuse,current transformer,over-voltage protection,crankcase heating,temperature limit protection logic,compressor overload sensing Soft-start to reduce current demand during compressor start •Nominal cooling capacities are based on:Indoor temperature:60°F DB,67°F WB.Outdoor temperature:95°F DB,75°F WB. Samsung HVAC maintains a policy of ongoing development,specifications are subject to change without notice.Refer to Warranty www.AHRldirectory.org for current reference numbers. 7 Years compressor,5 years parts with registration F/ Notice:US Federal law requires that the above model to be installed in all U.S.states and territories except In AZ,CA, NN, ARAN and NV.Federal law prohibits Installation of this unh In these states. ruN.a CERTIFIED. ©2017 Samsung HVAC 888-699-6067 AMStitidv1z`11. "'�° SHA-CAC-11202017 www.SamsungHVAC.com Intertek S■ M s U N 0 SUBMITTAL AC018MNADCH/AA, AC018MXSCCC/AA Page 2 of 3 Samsung,Low Ambient Cooling,High-Wall Evaporator,Split System AC018MNADCH/AA Dimensional Drawing r — --T-r 0 0 o Q_ _u.—=—= — — RIGHT TOP 10 3/8" LEFT 35 1/4" —...m — .. "=�lam'-.,`..,...—.....;.T....„--____=___:___- --=------ _�---- � ■ .--_.lam�• --- �'--- e 0 zo to ...albs_ .." - _.... .. �... I� th co FRONT Knockout hole for \IR receiver/ right piping 1 7/8" Knockout hole for ON/OFF button left piping ../..Iii\ • 0 0 . ii ,i''\'' BOTTOM W- 2 1/4" w 4 15/16" i 35 1/4" .4 w- -... - OD 7 1/2" 7 1/2" t 11.1 IF °A "v 3 1/2" 0.,, A Q 00 °oQ ° �,o°� O o°O° O°o°�° ° oo; r 15/16" ec. 2. ° 000 ° ° ca .. a_ oo ° o � ' ' •\N III . , , Li .8.. , n in .6. I stallat o Plate 1 1 in ft) iz"-- 14 15/16" 3 5/16" 3 5/16" Wall hole for r"F111.' II 111P. ill O. Left Rear Piping 7 15/16" 3 3/16" Wall hole for RightRear Piping No. Name Description 1 Liquid pipe connection 1/4" 2 Gas pipe connection 1/2" 3 Drain pipe connection 11/16"OD 4 Power supply&Communication wiring conduit - 888-699-6067 www.SamsungHVAC.com S A M S U N G SUBMITTAL AC018MNADCH/AA, AC018MXSCCC/AA Page 3 of 3 •y, Samsung,Low Ambient Cooling,High-Wall Evaporator,Split System AC018MXSCCC/AA Dimensional Drawing 36 9/16" MIIIIIIIIMIIMINFIC 111=111111 Zo n � — u 34 5/8" 12 3/16" ® Q. -?/,/iii.— .�:•l.`s.-\A�.il\Y: I!i 11IIII °N�`�ic i:Eei� llllilIIIIII IIIIt•-•1a •lig l)a lllh `_$ __ L_ III 9 1/4" 4115/161.1..„.„ 26" , % IF:: All © r 11! ' iiiip.pgra4- L.---N-#3. 1101 t..., ,,, ri 'I1 1/4" i � 6 9/16" No. Name Description p Gas Pipe Connection 0 1/4"Flare (lLiquid pipe Connection 0 1/2'Flare © Drain Hole - 888-699-6067 www.SamsungHVAC.com