Report J7 MAIN 1-25-16 0 Roseburg2:26pm A Forest Products Compan1 of 1 CS Beam 2015.7.0.1 kmBeamEngine 4.13.10.1 Materials Database 1543 Member Data Description: Member Type:Joist Application: Floor Top Lateral Bracing: Continuous Bottom Lateral Bracing: Continuous Standard Load: Moisture Condition: Dry Building Code: IBC/IRC Live Load: 40 PSF Deflection Criteria: L/480 live, L/240 total Dead Load: 12 PSF Deck Connection: Glued&Nailed Filename: Beam1 si`2 ,v,3 far »,'i xmx t -'r r mg,,imgr 3m`..a 4 mf,: .. r 'tT: ^r > 11 0 0 14 6 0 9 2560 Bearings and Reactions Input Min Gravity Gravity Location Type Material Length Required Reaction Uplift 1 0' 0.000" Wall DFL Plate(625psi) 3.500" 1.750" 312# -15# 2 11' 0.000" Wall DFL Plate(625psi) 3.500" 3.500" 1103# -- 3 25' 6.000" Wall DFL Plate(625psi) 3.500" 1.750" 418# -- Maximum Load Case Reactions Used for applying point loads(or line loads)to carrying members Live Dead 1 257#(192p11) 55#(42p10 2 849#(637p1f) 255#(191p1f) 3 327#(245p1f) 91#(68p1f) Design spans 10' 9.375" 14' 3.375" Product: 9 1/2" RFPI-20 16.0" O.C. PASSES DESIGN CHECKS Design assumes continuous lateral bracing along the top chord. Design assumes continuous lateral bracing along the bottom chord. Lateral support is required at each bearing. Allowable Stress Design Actual Allowable Capacity Location Loading Positive Moment 1254.'# 2820.'# 44% 19.57' Even Spans D+L Negative Moment 1441.'# 2820.'# 51% 11' Total Load D+L Shear 596.# 1220.# 48% 11' Total Load D+L End Reaction 418.# 1151.# 36% 25.5' Even Spans D+L Int.Reaction 1103.# 1775.# 62% 11' Total Load D+L TL Deflection 0.2167" 0.7141" L/790 18.85' Even Spans D+L LL Deflection 0.1753" 0.3570" L/977 18.85' Even Spans L Control: Max Int.React. DOLs: Live=100% Snovv=115% Roof=125% Wind=160% SIMPSON All product names are trademarks of their respective owners KAMI L HENDERSON EWP MANAGER Strong-Tie Copyright(C)2015 by Simpson Strong-Tie Company Inc.ALL RIGHTS RESERVED. PACIFIC LUMBER&TRUSS "Passing is defined as when the member,floor joist,beam or girder,shown on this drawing meets applicable design criteria for Loads,Loading Conditions,and Spans listed on this sheet.The design BEAVERTON,OREGON must be reviewed by a qualified designer or design professional as required for approval.This design assumes product installation according to the manufacturers spedfications. 503-858-9663