Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans (75)
MST2019-00036 114214 SW GOLD COAST TER run. icr, MST2019-00037 114208 SW GOLD COAST TER MST2019-00038 114204 SW GOLD COAST TER FEBs '7 2-019 MST2019-00039 114200 SW GOLD COAST TER 1t'� a Mlie k® MST2019 00040 1 14194 SW GOLD COAST TER CM' g �� OFFICE COPY MiTek USA, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Re: PL18-347_UPPER Fax 916/676-1909 POLYGON The truss drawing(s)referenced below have been prepared by MiTek USA, Inc.under my direct supervision based on the parameters provided by Pacific Lumber&Truss Co.. Pages or sheets covered by this seal: R55803484 thru R55803498 My license renewal date for the state of Oregon is June 30, 2019. `S�� F Fe 74GNE4\ 87022PEr -57 Aj, OREGON ci5:) / Of-) 4/SER 1.��Q�O A. H . EXP RES: 06/31/ 119 October 12,2018 Hernandez,Marcos IMPORTANT NOTE:Truss Engineer's responsibility is solely for design of individual trusses based upon design parameters shown on referenced truss drawings. Parameters have not been verified as appropriate for any use. Any location identification specified is for file reference only and has not been used in preparing design. Suitability of truss designs for any particular building is the responsibility of the building designer, not the Truss Engineer, per ANSI/I-PI-1, Chapter 2. Job Truss Truss Type Qty Ply POLYGON R5580)484. PL18-347_UPPER F01 Floor 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:13 2018 Page 1 I D:SeV?tdjYi Iz0X2xysi FDVpzsmU O-UCKzNysVerr6x5d1 WOjtaNByTxd KxNrBF9jrL0yL19Hu 1-9-12 I 2-6-0 Scale=1:17.7 1.5x3 II 3x4 = 1.5x3 II 3x4 = 1.5x3 H 1 2 3 4 5 Op? 8OJx�/> 7 0 w " 3x5 3x4 = 3x4= 9-8-4 I 0-1-b 9-6-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (Ioc) I/deft Lid PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.01 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.16 Vert(TL) -0.06 6-7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.01 6 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:47 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=420/0-4-0,8=420/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-688/0,3-4=-688/0 BOT CHORD 7-8=0/430,6-7=0/536 WEBS 4-6=-626/0,2-7=0/300,2-8=-557/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �<, 'kk° PROF Fs S.D. ANG I N EER cSj%29 870 2PE v (J) N - SAT OREGON tic3 OWN �C'�SA•�BER �' ' ' A. EXPIRES: 06/30/2019 October 12,2018 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 11111 Design valid for use only with MiTekSt connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSUTPI1 Quality Criteria,DSB-89 and BCSI Building Component 777757 re Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job a Truss Truss Type Qty Ply POLYGON PL18-347_UPPER F02 Floor R55803485 12 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:13 2018 Page 1 D:SeV?tdjYi IzOX2xysiFDVpzsmUO-UCKzNysVerr6x5dl WOjtaNByNxbIxJOBF9jrLOyU9 Hu 1 0-9-4 1 2-6-0 Scale=1:23.4 1.5x3 II 4x8 = 1.5x3 II 3x4 = 1.5x3 II 3x5 = 1.5x3 II 1 23 7 0 4 5 6 m o —.. N - 1/°1/°/'— 0 e 11 10 9 8 4x4 = 4x8 = 3x8= 3x5= 01118 13-9-4 0-1-8 13-7-12 I Plate Offsets(X,Y)— f11:Edoe,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.04 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.26 Vert(TL) -0.09 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.42 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight 67 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=600/0-1-8,11=600/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1028/0,3-4=-1028/0,4-5=-1282/0,5-6=-1282/0 BOT CHORD 10-11=0/323,9-10=0/1326,8-9=0/834 WEBS 6-8=-973/0,6-9=0/523,4-10=-349/0,2-10=0/822,2-11=-680/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. eA),0 PR Open • 041 �� 9 2 87022PE vr- v' N �-$, OREG N do Q4� On LIBER til S A. H ERCP EXPIRES: 06/30/2019 October 12,2018 t AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. .1111 Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not , a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MI ire IC is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights.CA 95610 Job Truss Truss Type Qty Ply POLYGON R5580-";486, PL18-347_UPPER F03 Floor 22 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:14 2018 Page 1 I D:SeV?tdjYi Iz0X2xysiFDVpzsmUO-yOuLbIt7P9zzZFCU46E66bk73LxPgn9 LTpSOtSyU9Ht 2-1-4I 2-6-0 Scale=1:25.6 1.5x3 II 4x6 = 1.5x3 II 3x4 = 1.5x3 II 3x8= 1.5x3 II 1 2 3 4 5 6 7 e H17,7 o _ o _ 0 I) o a o 10 9 8 3x5 = 4x8= 3x8 = 3x5 = 15-1-4 I 00-1-8 14-11-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.06 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.30 Vert(TL) -0.10 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.36 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:71 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=659/0-1-8,11=659/0-1-12 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-1418/0,3-4=-1418/0,4-5=-1476/0,5-6=-1476/0 BOT CHORD 10-11=0/811,9-10=0/1620,8-9=0/931 WEBS 6-8=-1086/0,6-9=0/636,2-10=0/709,2-11=-995/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. <��ti0 PROFFS 44/ 17 't 87022PE c' N -111.44r-1N yt‘Aj, OREGON t1,, Q4v� 'A�,ok',1,S ER 1' A. HE EXPIRES: 06/30/2019 October 12,2018 1 • A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. ; Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall Wel( design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB7777 -89 and BCSI Building Component 7777 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803487 'L18-347_UPPER F04 Floor 6 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:14 2018 Page 1 ID:5eV?tdpifilz0X2xysiFDVpzsmUO-yOuLbIt7P9zzZFCU46E66bk79LyAgm?LTpSOtSyUgHt P-4- 2-6-0 Scale=1:22.6 5x8= 1.5x3 II 1.5x3 II 3x4 = 1.5x3 II 3x5 = 1.5x3 II 1 2 3 4 5 6 7 L 7 9 o e p 11 10 9 8 5x5 = 4x8= 3x6 = 3x4= 01118 13-4-0 0-1-8 13-2-8 Plate Offsets(X.Y)— (11:Edae,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.04 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.25 Vert(TL) -0.08 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.43 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:65 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=581/0-1-8,11=581/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-899/0,3-4=-899/0,4-5=-1219/0,5-6=-1219/0 BOT CHORD 9-10=0/1230,8-9=0/802 WEBS 6-8=-936/0,6-9=0/486,4-10=-387/0,2-10=0/855,2-11=-670/0 NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �ti,`v° PR0re ,NI- �NG�NEFR /a2 87022PE 9r u) w Is 41),OREGON tis Q�N or, MBER 1 S A. Heck • EXPIRES: 06/30/2019 October 12,2018 I t A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design.Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Oty Ply POLYGON ' R55803488. PL18-347 UPPER F05 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:15 2018 Page 1 I D:5eV?tdjYi Iz0X2xysiFD VpzsmUO-QaSjoeulAT5pAOnhepl LfoGDKIFOPBtUiTCxPvyU9Hs' 1-10-4 2-6-0 Scale=1:25.1 3x4 II 4x10 = 1.5x3 II 3x4= 1.5x3 II 4x10 = 3x4 II 1 12 2 13 3 14 4 15 16 5 17 6 18 19 7 • o m / o 0 9 of 10 ® e 4x8 = 4x10= 4x8= 4x8 = I 15-1-4 I 15-1-4 Plate Offsets(X,Y)— 11:Edae,0-1-81,[8:Edge,0-1-81,111:Edae,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.47 Vert(LL) -0.09 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.44 Vert(TL) -0.15 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.52 Horz(TL) 0.04 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight 75 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=1049/0-5-8,8=1092/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2144/0,3-4=-2144/0,4-5=-2274/0,5-6=-2274/0 BOT CHORD 10-11=0/1265,9-10=0/2471,8-9=0/1569 WEBS 6-8=-1819/0,6-9=0/823,5-9=-278/0,4-10=-382/0,3-10=-307/0,2-10=0/1027,2-11=-1603/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)152 lb down at 13-2-8,152 lb down at 2-3-0,117 lb down at 1-5-7,112 lb down at 3-0-10,112 lb down at 4-7-13,112 lb down at 6-3-0,112 lb down at 7-10-3, 112 lb down at 9-5-6,112 lb down at 11-0-9,and 112 lb down at 12-7-12,and 118 lb down at 14-2-15 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LCASEStandard 1)OAD Dead+Floor(S)Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 �,'L O P R°FFS Uniform Loads(plf) c,'8 G)NE c5'� Vert:8-11=-5,1-7=-50 ���, oN FR 02� Concentrated Loads(Ib) Vert:6=-112(F)3=-112(F)2=-152(F)12=-117(F)13=-112(F)14=112(F)15=-112(F)16=-112(F)17=-112(F)18=-152(F) C 87022PE r 19=-118(F) yN N �Aj, OREGON q, O 'AOr) BER \\�Q� ka A. H,GR EXPIRES: 06/30/2019 October 12,2018 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. mit Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803489 ?L18-347_UPPER F06 FLOOR GIRDER 2 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:17 2018 Page 1 ID:5eV?tdjYi Iz0X2xysiFDVpzsmUO-NzaUDKv?i4LXQix3lEopkDLesYat9Vn9nh2UnyU9Hq 1-10-4 I 2-6-0 Scale=1:25.1 3x4 II 3x5 = 1.5x3 II 3x4= 1.5x3 II 3x4 = 3x4 II 1 2 3 4 5 6 7 • 0 ro e o - Cr ,111111, 10 g 3x6 = 3x6 = 3x6 = 3x6 = I 15-1-4 15-1-4 Plate Offsets(X,Y)— 11:Edge,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.13 Vert(LL) -0.04 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.20 Vert(TL) -0.07 8-9 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.26 Horz(TL) 0.01 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight 75 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 11=408/0-5-8,8=408/0-5-8 Max Uplift 11=-122(LC 6),8=-122(LC 7) Max Gray 11=487(LC 3),8=487(LC 2) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 1-2=-262/262,2-3=-957/163,3-4=-957/164,4-5=-1006/150,5-6=-1006/150, 6-7=-348/348 BOT CHORD 10-11=-251/634,9-10=-144/1068,8-9=-229/734 WEBS 6-8=-858/275,6-9=-304/615,4-9=-411/388,4-10=-432/373,2-10=-293/674, 2-11=-730/221 NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Provide mechanical connection(by others)of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)except(jt=lb) 11=122,8=122. 3)This truss has been designed for a total drag load of 2000 lb.Lumber DOL=(1.33)Plate grip DOL=(1.33) Connect truss to resist drag loads along bottom chord from 0-0-0 to 15-1-4 for 132.4 plf. 4)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. �ED PR Qp- Strongbacks to be attached to walls at their outer ends or restrained by other means. �• ., NG N SFR sip -"4 87022P 9r >• " -y << 1.... OREGON 45) vb 9On ER '\'\\•••\‘'4..)� A. HER EXPIRES: 06/30/2019 October 12,2018 I t 1 __ A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,notligt a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803490. PL18-347 UPPER F07 Floor 4 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mari 1 2018 MiTek Industries,Inc. Fri Oct 12 12:38:17 2018 Page 1 ID:5eV?tdjYi Iz0X2xysiFD VpzsmU O-NzaU DKv?i4LXQix3l EopkDLeVY0ftDsn9nh2UnyU9Hq 0-11-4 2-6-0 I 1 1.5x3 II 2 3x4 = 3 1.5x3 II Scale=1:11.1 II II II WM II O O I Ailli I FAN F2 5 72'-' LI 3x4= 3x4 = d-1- 3-8-4I 3-6-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) 0.00 5 **** 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.07 Vert(TL) -0.02 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.04 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-P Weight:20 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-8-4 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=157/0-4-0,5=157/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. (¢vo PR R OFFss ,,( -Nc NEF'4 /029 � 87022PE r (f).11--/-4-9N y �'$, OREGON rt-;) 4qtr On A. HES EXPIRES: 06/30/2019 October 12,2018 t f A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIITPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803491 Pp8-347_UPPER F08 Floor 14 1 Job Reference(optional) Pacific,Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:19 2018 Page 1 I D:5eV?tdjYi Iz0X2xysiFDVpzsmUO-JMh EeOxGEhcFf04StfgHpeRzSMi I K7D4d5A9YgyU9Ho 2-6-0 I 0-11-12 I 0-6-12 4x41= 1 1.5x3 II 2 3x4= 3 3x4 I I 4 Scale=1:11.1 J / . 7 S 5 1.5x3 II 3x4 = 40o-4 10-4 , 1 3-7-4 3r8-1R I 4-6-8 I 3-7-4 0.1-8 0-8-4 0-1-8 Plate Offsets(X,Y)- 14:0-1-8,Edoel LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.21 Vert(LL) 0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.06 Vert(TL) -0.01 6-7 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-P Weight:28 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-6-8 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 7=128/Mechanical,6=385/0-6-0 Max Gray 7=152(LC 3),6=385(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)125 lb down at 4-5-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) c ) PR OF es Vert:Concentrated Loads'(lbj_-60 �Co� AGI NES- 6/^ Vert:4=125(F) ,. .Z 87022P -17_._. d CV n �Aj, OREGON cp 4v4 '9Or, ER '\'`�Q�O A. He EXPIRES: 06/30/2019 October 12,2018 4 t A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. mil- Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803492 PL18-347_UPPER F09 Floor 15 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:19 2018 Page 1 I D:5eV?tdjYilz0X2xysi FDV pzsmUO-JMh Ee0xGEhcFf04StfgHpeRzXMIZK784d5A9YgyU9Ho I 2-6-0I 0-5-12 I 0-6-12 4x41= 1 1.5x3 II 2 4x4 = 3 3x4 II 4 Scale=1:11.1 • 0 C S1.5x3 II 7 5 3x4= 4r34 I 3-1-4 3t2-1l 1 4-0-8 I 3-1-4 41- 0-8-4 0-1-8 Plate Offsets(X,Y)— j4:0-1-8,Edciej LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/dell L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.20 Vert(LL) 0.00 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.04 Vert(TL) -0.01 6-7 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.06 Horz(TL) 0.00 6 n/a n/a BCDL 5.0 Code IBC2012ITP12007 Matrix-P Weight:27 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 4-0-8 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. REACTIONS. (lb/size) 7=102/Mechanical,6=368/0-6-0 Max Gray 7=129(LC 3),6=368(LC 1) FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Unbalanced floor live loads have been considered for this design. 2)Refer to girder(s)for truss to truss connections. 3)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 4)CAUTION,Do not erect truss backwards. 5)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)125 lb down at 3-11-12 on top chord. The design/selection of such connection device(s)is the responsibility of others. 6)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 Uniform Loads(plf) � ,$),..1)cPROpen Vert:5-7=-8,1-4=-80 C.: (' G Concentrated Loads(lb) \ �Nv i.• Vert:4=-125(F) � k 87022PE T" N 7" IV y LIN 7" OREGON (-P 4 �C,n BER \\ •' .. A. HEP EXPIRES: 06/30/2019 October 12,2018 t ) A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MI1-7473 rev.10/03/2015 BEFORE USE. Mit Design valid for use only with MiTek8t connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing M iTek" is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 • Job Truss Truss Type Qty Ply POLYGON PL18-347 UPPER F10 R55803493 Floor 6 1 Job Reference(optional) Pacifip Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:20 2018 Page 1 ID:SeV?tdjYi IzOX2xysiFDVpzsmUO-nYFcrLyu??k6HAfeQM LWMsz9im2g3ZUDsIvi56yU9Hn 0-5-4 2-6-0 I 1 1.5x3 II 2 4x4 = 3 1.5x3 II Scale=1:11.2 5 • 454 = 3x4 = 3-2-4 1 3-0-12 Plate Offsets(X,Y)— I5:Edge,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) 0.00 5 ***' 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.05 Vert(TL) -0.01 4-5 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.05 Horz(TL) 0.00 4 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-P Weight 18 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 3-2-4 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 4=135/0-4-0,5=135/Mechanical FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. NOTES- 1)Refer to girder(s)for truss to truss connections. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. `3'��/ 4GINE4\ cc 87022PE 9r N �'oj`OREGON (15)Q�N O MSER. On A. H E¢�P EXPIRES: 06/30/2019 October 12,2018 4 4 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. mit Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not _ a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TPII Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON r R55803494, PL18-347_UPPER F11 Floor 33 1 , Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:20 2018 Page 1, ID:SeV?tdjYi Iz0X2xysiFDVpzsmUO-nYFcrLyu??k6HAfeQM LWMsz9Ym_u3U WDsIvi56yU9Hn 1-11-4 I 2-6-0 I Scale=1:25.4 1.5x3 II 4x6= 1.5x3 II 3x4 = 1.5x3 II 3x6= 1.5x3 II 1 2 3 4 5 6 7 U i e _ e 0 0 o 8 1'4 10 9 3x5 = 3x5 = 4x8 = 3x8= 14-11-4 I 0-1-8 14-9-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.06 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.29 Vert(TL) -0.10 8-9 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.37 Horz(TL) 0.02 8 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight:71 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 8=651/0-1-8,11=651/0-1-12 FORCES. (lb)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1369/0,3-4=-1369/0,4-5=1452/0,5-6=-1452/0 BOT CHORD 10-11=0/748,9-10=0/1583,8-9=0/919 WEBS 6-8=-1072/0,6-9=0/622,2-10=0/725,2-11=-945/0 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)8,11. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 'cti�°D PRQFFs NG►NSFS/ , NFR 0 t. 87022PE -r_.... f� N -1 �'OT OREGON tis QiN 'A�'OSMBEFt �� P� A. HE EXPIRES: 06/30/2019 October 12,2018 I, AWARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. 111",t Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall MiTek' building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSITTPII Quality Criteria,DSB-89 and BCSI Building Component 7777777 Greenback Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 • Job • Truss Truss Type Qty Ply POLYGON PL18-347_UPPER F12 Floor 24 1 R55803495 Pacific Lumber&Truss Co., Beaverton,Oregon Job Reference(optional) 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:21 2018 Page 1 ID:SeV?tdjYi Iz0X2xysiFDVpzsm UO-Fkp_3hyWmJszuJEg_4slv3 WKR9MnoytN4PfGdYyU9Hm I 0-10-0 I I 2-6-0 I Scale=1:19.2 1.5x3 II 3x4 = 1.5x3 II 1 4x4 = 2 3x4= 1.5x3 I ° 3 4 5 6 L 0 2 ° 1oXX 9 ® ° 4x5= 8 1.5x3 II 3x5 = 7 3x4 = I 11-4-0 11-4-0 Plate Offsets(X,Y)— 11:Edcte,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.18 Vert(LL) -0.02 8 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.19 Vert(TL) -0.07 7-8 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.30 Horz(TL) 0.01 7 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight 56 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 10=493/0-4-0,7=493/0-1-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 1-10=-501/0,1-2=-309/0,2-3=-309/0,3-4=-927/0,4-5=-927/0 BOT CHORD 8-9=0/795,7-8=0/656 WEBS 5-7=-766/0,5-8=0/315,3-9=-567/0,1-9=0/584 NOTES- 1)Provide mechanical connection(by others)of truss to bearing plate at joint(s)7. 2)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. ,,_ 'Q2 87022PE yr N 7 j,OREGON c15) 11N C MBER1� �S A. HE��P EXPIRES: 06/30/2019 October 12,2018 t , ®WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MIl-7473 rev.10/03/2015 BEFORE USE. alla Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall . building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the MiTek- fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/TP11 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON R55803496• PL18-347_UPPER F13 FLOOR GIRDER 3 1 , Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:21 2018 Page 1F I D:SeV?tdjYi Iz0X2xysiFDVpzsmUO-Fkp_3hyWmJszuJEq-4SIv3WKe9HZopfN4PfGdYyU9H m 1-2-12 1-10-0 1-8-8 Scale=1:24.8 3x4 II 6x12 = 3x4 II 3x4 = 1.5x3 II 3x4 = 1.5x3 II 4x8 = 3x4 II 2 3 4 5 6 7 8 a - I/ . ob tr 13 ® 12 11 5x8 = 6x16= 3x5 = 4x10 = 4x6 = 14-11-4 II 14-11-4 Plate Offsets(X 11— [1:Edae,0-1-8],f10:Edge,0-1-81.[14:Edde,0-1-81 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) 1/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.16 Vert(LL) -0.08 12 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.46 Vert(TL) -0.13 12-13 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.89 Horz(TL) 0.04 10 n/a n/a Weight:80 lb FT=0%F,50%E BCDL 5.0 Code IBC2012/TP12007 Matrix-R LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 14=1285/0-5-8,10=832/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-2457/0,3-4=-2458/0,4-5=-2473/0,5-6=-2473/0,6-7=-1673/0,7-8=-1673/0 BOT CHORD 13-14=0/1086,12-13=0/2559,11-12=0/2168,10-11=0/960 WEBS 8-10=-1222/0,8-11=0/920,6-11=-638/0,6-12=0/393,3-13=-967/0,2-13=0/1745,2-14=-1646/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)825 lb down at 3-6-0 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead 1 •• '.- .. . --.- - -- -- -- _ - -= is Uniform Loads ����') P R Qp- Vert:10-10-1 4=-8,1-9=-80 Concentrated Loads(lb) •� ,,‘,AGINE .. si0 Vert:3=-825(F) mc.? ?/. ct 87022PE r /1°64N 9 R`,o OREGON q5) 4/ ��C�pSM14 BER 1 \Q A HEPs EXPIRES: 06/30/2019 October 12,2018 4 —� 4 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII.7473 rev.10/03/2015 BEFORE USE. mit Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and property incorporate this design into the overall MiTek'design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 7777 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSIR PI7 Quality Criteria,DSB-89 and BCSI Building Component 7 Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suras Heights,CA 95610 Job • s ' Truss Truss Type Qty Ply POLYGON PL18-347 3 1 UPPER F14 FLOOR GIRDER R55803497 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:22 2018 Page 1 ID:5eV?tdjYilz0X2xysiFDVpzsmUO-jxNNG1z8Xc gWTpIYnN_RH3RCZfAXM?WJ30p9?yU9H1 1-8-4 I 2-6-0 Scale=1:24.8 3x4 II 4x8 = 1.5x3 II 3x4 = 1.5x3 II 4x8 = 3x4 II 1 12 2 13 14 3 15 4 16 5 17 6 18 4 --. /. 2 m p 10 9 4x6 = 4x10= 4x8= 4x6 = I 14-11-4 14-11-4 Plate Offsets(X,Y)— [1:Edge,0-1-8],f8:Edge,0-1-81 LOADING (psf) SPACING- 1-0-0 CSI. DEFL. in (Icc) 1/defl L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.37 Vert(LL) -0.07 9-10 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.37 Vert(TL) -0.12 9-10 >999 360 BCLL 0.0 Rep Stress Incr NO WB 0.50 Horz(TL) 0.03 8 n/a n/a BCDL 5.0 Code IBC2012/TPI2007 Matrix-R Weight:74 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (Ib/size) 11=873/0-5-8,8=833/0-5-8 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(Ib)or less except when shown. TOP CHORD 2-3=-1758/0,3-4=-1758/0,4-5=-1867/0,5-6=-1867/0 BOT CHORD 10-11=0/921,9-10=0/2041,8-9=0/1245 WEBS 6-8=-1444/0,6-9=0/726,4-10=-331/0,3-10=-308/0,2-10=0/977,2-11=-1209/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. 2)Hanger(s)or other connection device(s)shall be provided sufficient to support concentrated load(s)129 lb down at 3-11-8,129 lb down at 13-3-0,100 lb down at 0-8-9,95 lb down at 2-3-12,89 lb down at 5-6-2,89 lb down at 7-1-5,89 lb down at 8-8-8,and 89 lb down at 10-3-11,and 89 lb down at 11-10-14 on top chord. The design/selection of such connection device(s)is the responsibility of others. 3)In the LOAD CASE(S)section,loads applied to the face of the truss are noted as front(F)or back(B). LOAD CASE(S) Standard 1)Dead+Floor Live(balanced):Lumber Increase=1.00,Plate Increase=1.00 `��°D PR OFFS Uniform Loads(plf) Vert:Loads(lb) ��5 NGINEF �/O Concentrated Loads R Vert:6=89(F)4=-89(F)12=-100(F)13=-95(F)14=-129(F)15=-89(F)16=-89(F)17=-89(F)18=-129(F) 0 $7022 PE �r -0j`OREGON , O4i O� OREGON � SSA. HEA EXPIRES: 06/30/2019 October 12,2018 t A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MII-7473 rev.10/03/2015 BEFORE USE. Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not < a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing Mel(' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSITTPI1 Quality Criteria,DSB-89 and BCSI Building Component 7777 Greenback Lane Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Suite 109 Citrus Heights,CA 95610 Job Truss Truss Type Qty Ply POLYGON • , R55803498• PL18-347_UPPER F15 Floor 3 1 Job Reference(optional) Pacific Lumber&Truss Co., Beaverton,Oregon 8.130 s Mar 11 2018 MiTek Industries,Inc. Fri Oct 12 12:38:22 2018 Page 1_, ID:5eV?tdjYilz0X2xysiFDVpzsmUO-jxNNG 1 z8Xc_gWTp1 YnN_RH3UCZiVXR8 WJ3Op9?yU9Hl I 1-5-12 2-6-0 Scale=1:17.1 1.5x3 II 3x4 = 1.5x3 II 3x4 = 1.5x3 II 1 2 3 4 5 m 7 e 8 e 0 ./ 3x5 = 3 3x4= x4 = 9-4-4 j 0-1-8 9-2-12 LOADING (psf) SPACING- 1-7-3 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 40.0 Plate Grip DOL 1.00 TC 0.17 Vert(LL) -0.01 7 >999 480 MT20 220/195 TCDL 10.0 Lumber DOL 1.00 BC 0.15 Vert(TL) -0.07 6-7 >999 360 BCLL 0.0 Rep Stress Incr YES WB 0.17 Horz(TL) 0.01 6 n/a n/a BCDL 5.0 Code IBC2012/TP12007 Matrix-R Weight 46 lb FT=0%F,50%E LUMBER- BRACING- TOP CHORD 2x4 DF No.1&Btr(flat) TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2x4 DF No.1&Btr(flat) except end verticals. WEBS 2x4 DF Stud/Std(flat) BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 6=406/0-4-0,8=406/0-4-4 FORCES. (Ib)-Max.Comp./Max.Ten.-All forces 250(lb)or less except when shown. TOP CHORD 2-3=-639/0,3-4=-639/0 BOT CHORD 7-8=0/356,6-7=0/511 WEBS 4-6=-597/0,2-7=0/330,2-8=-504/0 NOTES- 1)Recommend 2x6 strongbacks,on edge,spaced at 10-0-0 oc and fastened to each truss with 3-10d(0.131"X 3")nails. Strongbacks to be attached to walls at their outer ends or restrained by other means. �n D PR OFFS ��\�� �NC'I NE -,,,,, EER `S/p�9 87022PE / r N "5.y SAT OREGON ti�oti ��'QSMBER \��Q� A. HE EXPIRES: 06/30/2019 October 12,2018 t11110 A WARNING-Verify design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE M11-7473 rev.10/03/2015 BEFORE USE. NI Design valid for use only with MiTek®connectors.This design is based only upon parameters shown,and is for an individual building component,not a truss system.Before use,the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MiTek" building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only.Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 77 Greenback Lane fabrication,storage,delivery,erection and bracing of trusses and truss systems,see ANSI/7PII Quality Criteria,DSB-89 and BCSI Building Component 77 77 it7 re Safety Information available from Truss Plate Institute,218 N.Lee Street,Suite 312,Alexandria,VA 22314. Citrus Heights,CA 95610 Symbols Numbering System A General Safety Notes PLATE LOCATION AND ORIENTATION j 314" Center plate on joint unless x,y I 6-4-8 ( dimensions shown in ft-in-sixteenths Failure to Follow Could Cause Property 4 offsets are indicated. (Drawings not to scale) Damage or Personal Injury r� IErDimensions are in ft-in-sixteenths. h Apply plates to both sides of truss and fully embed teeth. 1 2 3 1. Additional stability bracing for truss system,e.g. TOP CHORDS diagonal or X-bracing,is always required. See BCSI. -1/16" O1"2 c2-3 2. Truss bracing must be designed by an engineer.For lilip,Mr 4 wide truss spacing,individual lateral braces themselves may require bracing,or alternative Tor I 11117RIE bracing should be considered. INIRIllip !)_ 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. O p 4. Provide copies of this truss design to the building For 4 x 2 orientation, locate °7-8 O6"' O5.8 H designer,erection supervisor,property owner and plates 0- 1r1/' from outside BOTTOM CHORDS all other interested parties. edge of truss. 8 7 6 5 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE joint and embed fully.Knots and wane at joint required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO locations are regulated by ANSI/TPI 1. connector plates. THE LEFT. 7. Design assumes trusses will be suitably protected from CHORDS AND WEBS ARE IDENTIFIED BY END JOINT the environment in accord with ANSI/TPI 1. *Plate location details available in MiTek 20/20 NUMBERS/LETTERS. software or upon request. 8. Unless otherwise noted,moisture content of lumber shall not exceed 19%at time of fabrication. PLATE SIZE PRODUCT CODE APPROVALS 9. Unless expressly noted,this design is not applicable for ICC-ES Reports: use with fire retardant,preservative treated,or green lumber. The first dimension is the plate 10.Camber is a non-structural consideration and is the 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 responsibility of truss fabricator.General practice is to to slots.Second dimension is ER-3907, ESR-2362,ESR-1397, ESR-3282 camber for dead load deflection. the length parallel to slots. 11.Plate type,sizeorientation andrequirelocationments.dimensions indicated are minimum plating LATERAL BRACING LOCATION 12.Lumber used shall be of the species and size,and /� Trusses are designedin all respects,equal to or better than that �i Indicated by symbol shown and/or for wind loads in the plane of the specified. by text in the bracing section of the truss unless otherwise shown. 13.Top chords must be sheathed or purlins provided at output. Use T or I bracing spacing indicated on design. if indicated. Lumber design values are in accordance with ANSI/TPI 1 14.Bottom chords require lateral bracing at 10 ft.spacing, section 6.3 These truss designs rely on lumber values BEARING or less,if no ceiling is installed,unless otherwise noted. established by others. 15.Connections not shown are the responsibility of others. II Indicates location where bearings (supports)occur. Icons vary but ©2012 MiTek®All Rights Reserved 16.Do not cut or alter truss member or plate without prior k=I# reaction section indicates joint approval of an engineer. 1.= number where bearings occur. 17.Install and load vertically unless indicated otherwise. Min size shown is for crushing only. �� E4 0 18.Use of green or treated lumber may environental,health or performane risks. with Industry Standards: project engineer before use. ANSI/TPI1: National Design Specification for Metal III19.Review all portions of this design(front,back,words Plate Connected Wood Truss Construction. and pictures)before use.Reviewing pictures alone DSB-89: Design Standard for Bracing. is not sufficient. I �' BCSI: Building Component Safety Information, '� 20.Design assumes manufacture in accordance with Guide to Good Practice for Handling, ANSI/TPI 1 Quality Criteria. Installing&Bracing of Metal Plate Connected Wood Trusses. MiTek Engineering Reference Sheet:MII-7473 rev.10/03/2015