Loading...
Plans (68) ��ED PROpSS � J l�l��V�C%- <- Co W ,.14/ <c, 3 94/E � lack O7 C Alpine,an ITW Company •"••• 8351 Rovana Circle Sacramento,CA 95828 ALPINE Phone:(800)877-3678(916)387-0116 OREGON Fax:(916)387-1110 154,061,:o7 'Z�y 14 2000 ec sacseals@itwbcg.com l Tah 12/07/2018 Renewal 6/30/2020 DECEIVED APR 4 2019 CITY OF TIGARD 3UILDING DIVISION Site Information: Page 1: Customer: Oregon Truss Job Number: 40 stockOTC Job Description: 40 stock OTC Address: Job Engineering Criteria: Design Code: IBC 2015 View Version: IBC 2015 JRef#. 1WGO4350001 Wind Standard: ASCE 7-10 Roof Load(pdf): 25.00-7.00-0.00-1.00 Wind Speed(mph): 120 Floor Load(psf): None This package contains general notes pages,2 truss drawing(s)and 1 detail(s). Item Seal# Truss Item Seal# Truss 1 341.18.0856.39283 40-4_STOCK 2 341.18.0858.13703 40-4_STOCK_GE Printed 12/7/2018 9:23:13 AM General Notes Truss Design Engineer Scope of Work, Design Assumptions and Design Responsibilities: The design responsibilities assumed in the preparation of these design drawings are those specified in ANSI/TPI 1, Chapter 2; and the National Design Standard for Metal Plate Connected Wood Truss Construction, by the Truss Plate Institute. The truss component designs conform to the applicable provisions of ANSI/TPI 1 and NDS, the National Design Specification for Wood Construction by AF&PA. The truss component designs are based on the specified loading and dimension information furnished by others to the Truss Design Engineer. The Truss Design Engineer has no duty to independently verify the accuracy or completeness of the information provided by others and may rely on that information without liability. The responsibility for verification of that information remains with others neither employed nor controlled by the Truss Design Engineer. The Truss Design Engineer's seal and signature on the attached drawings, or cover page listing these drawings, indicates acceptance of professional engineering responsibility solely for the truss component designs and not for the technical information furnished by others which technical information and consequences thereof remain their sole responsibility. The suitability and use of these drawings for any particular structure is the responsibility of the Building Designer in accordance with ANSI/TPI 1 Chapter 2. The Building Designer is responsible for determining that the dimensions and loads for each truss component match those required by the plans and by the actual use of the individual component, and for ascertaining that the loads shown on the drawings meet or exceed applicable building code requirements and any additional factors required in the particular application. Truss components using metal connector plates with integral teeth shall not be placed in environments that will cause the moisture content of the wood in which plates are embedded to exceed 19% and/or cause corrosion of connector plates and other metal fasteners. The Truss Design Engineer shall not be responsible for items beyond the specific scope of the agreed contracted work set forth herein, including but not limited to: verifying the dimensions of the truss component, calculation of any of the truss component design loads, inspection of the truss components before or after installation, the design of temporary or permanent bracing and their attachment required in the roof and/or floor systems,the design of diaphragms or shear walls, the design of load transfer connections to and from diaphragms and shear walls, the design of load transfer to the foundation, the design of connections for truss components to their bearing supports, the design of the bearing supports, installation of the truss components, observation of the truss component installation process, review of truss assembly procedures, sequencing of the truss component installation, construction means and methods, site and/or worker safety in the installation of the truss components and/or its connections. This document may be a high quality facsimile of the original engineering document which is a digitally signed electronic file with third party authentication. A wet or embossed seal copy of this engineering document is available upon request. Temporary Lateral Restraint and Bracing: Temporary lateral restraint and diagonal bracing shall be installed according to the provisions of BCSI chapters B1, B2, B7 and/or B10 (Building Component Safety Information, by TPI and SBCA), or as specified by the Building Designer or other Registered Design Professional. The required locations for lateral restraint and/or bracing depicted on these drawings are only for the permanent lateral support of the truss members to reduce buckling lengths, and do not apply to and may not be relied upon for the temporary stability of the truss components during their installation. Permanent Lateral Restraint and Bracing: The required locations for lateral restraint or bracing depicted on these drawings are for the permanent lateral support of the truss members to reduce buckling lengths. Permanent lateral support shall be installed according to the provisions of BCSI chapters B3, B7 and/or B10, or as specified by the Building Designer or other Registered Design Professional. These drawings do not depict or specify installation/erection bracing, wind bracing, portal bracing or similar building stability bracing which are parts of the overall building design to be specified, designed and detailed by the Building Designer. Connector Plate Information: Alpine connector plates are made of ASTM A653 or ASTM A1063 galvanized steel with the following designations, gauges and grades: W=Wave, 20ga, grade 40; H=High Strength, 20ga, grade 60; S=Super Strength, 18ga, grade 60. Information on model code compliance is contained in the ICC Evaluation Service report ESR-1118, available on-line at www.icc-es.orq. Page 1 of 2 General Notes (continued) Key to Terms: Information provided on drawings reflects a summary of the pertinent information required for the truss design. Detailed information on load cases, reactions, member lengths, forces and members requiring permanent lateral support may be found in calculation sheets available upon written request. BCDL = Bottom Chord standard design Dead Load in pounds per square foot. BCLL = Bottom Chord standard design Live Load in pounds per square foot. Des Ld =total of TCLL, TCDL, BCLL and BCDL Design Load in pounds per square foot. HORZ(LL)= maximum Horizontal panel point deflection due to Live Load, in inches. HORZ(TL)= maximum Horizontal panel point long term deflection in inches, due to Total Load, including creep adjustment. HPL =additional Horizontal Load added to a truss Piece in pounds per linear foot or pounds. L/#= user specified divisor for limiting span/deflection ratio for evaluation of actual L/defl value. L/defl = ratio of Length between bearings, in inches, divided by the immediate vertical Deflection, in inches, at the referenced panel point. Reported as 999 if greater than or equal to 999. Loc= Location, starting location of left end of bearing or panel point(joint) location of deflection. Max BC CSI = Maximum bending and axial Combined Stress Index for Bottom Chords for of all load cases. Max TC CSI = Maximum bending and axial Combined Stress Index for Top Chords for of all load cases. Max Web CSI= Maximum bending and axial Combined Stress Index for Webs for of all load cases. NCBCLL= Non-Concurrent Bottom Chord design Live Load in pounds per square foot. PL = additional Load applied at a user specified angle on a truss Piece in pounds per linear foot or pounds. PLB = additional vertical load added to a Bottom chord Piece of a truss in pounds per linear foot or pounds PLT=additional vertical load added to a Top chord Piece of a truss in pounds per linear foot or pounds. PP = Panel Point. R= maximum downward design Reaction, in pounds, from all specified gravity load cases, at the indicated location (Loc). -R= maximum upward design Reaction, in pounds, from all specified gravity load cases, at the identified location (Loc). Rh = maximum horizontal design Reaction in either direction, in pounds,from all specified gravity load cases, at the indicated location (Loc). RL = maximum horizontal design Reaction in either direction, in pounds, from all specified non-gravity(wind or seismic) load cases, at the indicated location (Loc). Rw= maximum downward design Reaction, in pounds,from all specified non-gravity(wind or seismic) load cases, at the identified location (Loc). TCDL =Top Chord standard design Dead Load in pounds per square foot. TCLL=Top Chord standard design Live Load in pounds per square foot. U = maximum Upward design reaction, in pounds,from all specified non-gravity(wind or seismic) load cases, at the indicated location (Loc). VERT(CL) = maximum Vertical panel point deflection in inches due to Live Load and Creep Component of Dead Load in inches. VERT(LL)= maximum Vertical panel point deflection in inches due to Live Load. VERT(TL)= maximum Vertical panel point long term deflection in inches due to Total load, including creep adjustment. W=Width of non-hanger bearing, in inches. Refer to ASCE-7 for Wind and Seismic abbreviations. Uppercase Acronyms not explained above are as defined in TPI 1. References: 1. AF&PA: American Forest&Paper Association, 1111 19th Street, NW, Suite 800, Washington, DC 20036; www.afandpa.orq. 2. ICC: International Code Council;www.iccsafe.orq. 3. Alpine, a division of ITW Building Components Group Inc.: 13723 Riverport Drive, Suite 200, Maryland Heights, MO 63043; www.alpineitw.com. 4. TPI: Truss Plate Institute, 218 North Lee Street, Suite 312, Alexandria, VA 22314;www.tpinst.orq. 5. SBCA: Wood Truss Council of America, 6300 Enterprise Lane, Madison, WI 53719;www.sbcindustry.co Page 2 of 2 SEAN:55365 T1 COMN Ply: 1 Job Number. 40 stockOTC Gust:R435 JRef:1WG04350001 FROM:ER Qty: 30 40 stock OTC DrwNo: 341.18.0856.39283 Truss Label: 40-4 STOCK CY / RTT 12/07/2018 6'8" 12'11"820' 271"8 33'4" 40' 68" 6'3"8 I 7'0"8 -I- 7'0"8 -I 6,3"8 I 6'8" H0710 T2 E T3 ;H0508 �, H0508 4 12 ,5 C[7] D F 5X5[24] i co 3X7 3X7 B H Nopp _ ya III I el N M • B2 L K J P Pft H1015(B9R) =3X5 =SS0508 =5X8[17] =880508 =3X5 =H1015(B9R) A 40' j 10' I 10' 10' 10 10' 20' 30' 40' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria A Maximum Reactions(lbs) TCLL: 25.00 Wind Std: ASCE 7-10 Pg:25.0 Ct:1.2 CAT:II PP Deflection in loc L/defl L/# Gravity Non-Gravity TCDL: 7.00 Speed:120 mph Pf:25.0(specified) Ce:1.0 VERT(LL): 0.716 L 665 240 Loc R+ /R- /Rh /Rw /U /RL BCLL: 0.00 Enclosure:Part.Enc. Lu: - Cs:0.94 VERT(CL):0.956 L 498 180 0 4673 /- /- /1976 /1509 /323 BCDL: 1.00 Risk Category:II Snow Duration:1.15 HORZ(LL): 0.226 J - - P 4673 /- /- /1976 /1509 /- EXP:B Kzt:NA g HORZ TL:0.302 J - - Wind reactions based on MWFRS Des Ld: 33.00 Mean Height:17.96 ft ( ) Code/Misc Criteria CreepFactor:2.0 0 Brg Width=5.5 Min Req=5.0 NCBCLL:0.00 TCDL:3.0 psf P Brg Width=5.5 Min Req=5.0 Soffit: 0.00 BCDL:0.6sf Bldg Code: IBC 2015 Max TC CSI: 0.976 P Bearings 0&P area rigid surface. Load Duration:1.15 MWFRS Parallel Dist:0 to h/2 TPI Std: 2014 Max BC CSI: 0.996 Spacing:84.0" C&C Dist a:4.00 ft Rep Fac:No Max Web CSI:0.973 Members not listed have forces less than 375# P 9 Maximum Top Chord Forces Per Ply(lbs) Loc.from endwall:Any FT/RT/PT:6(0)/3(0)/1(0) Chords Tens.Comp. Chords Tens. Camp. GCpi:0.55 Plate Type(s): Wind Duration:1.60 HS,WAVE,18SS VIEW Ver:18.02.00.1016.21 A-B 7047-11370 E-F 4972 -7374 Lumber In lieu of purlins on the bottom chord at 44"o/c, C-D 4938 17531 F- 4938 -0323 the bottom chords of trusses placed each side C-D 4938-7533 G-H H 6508-10321 Top chord 2x6 DF-L 2100f-1.8E:T2,T3 2x6 DF-L D-E 4972-7374 H-I 7047-11370 1800f-1.8E: of supporting poles may be braced with purlins at Bot chord 2x6 DF-L 2100f-1.8E:B2 2x6 DF-L 20'0"o/c maximum spacing and H-brace blocking: 1800f-1.8E: (H)2X6 DF-L#2 or better continuous reinforcing Maximum Bot Chord Forces Per Ply(lbs) Webs 2x4 DF-L Standard:W4 2x4 DF-L 1800f-1.8E: member(match pole width).Attach to each truss Chords Tens.Comp. Chords Tens. Comp. :Lt Wedge 2x6 DF-L 1800f-1.8E: ply with 16D common nails(0.162"x3.5")at 12"o/c. :Rt Wedge 2x6 DF-L 1800f-1.8E: 111 el) / A-N 10616-6365 L-K 9168 -5315 1 N-M 9168-5313 K-J 9168 -5315 Bracing M-L 9168-5313 J-I 10616 -6364 (a)Continuous lateral restraint,equally spaced on member. Maximum Web Forces Per Ply(lbs) Webs Tens.Comp. Webs Tens. Comp. Plate Shift Table JT Plate Chord JT Plate Chord B-N 969-1218 L-G 1845 -2957 No Size Shift Bite No Size Shift Bite N-C 818 -592 G-J 818 593 [7] 5X5 2.25 L 3.00 [17] 5X8 S 1.50 C-L 1845-2957 J-H 969 -1218 [24] 5X5 2.25 R 3.00 E-L 2975-1907 Loading /S-1,agatTig1 Truss checked for 60#live and 0#dead movable A. �,6 t%N E . ��O. load along Bottom Chord,non-concurrent with any (2 y other live loads. 83294PE 7 Purlins .„,1„,,„,...-- ' In lieu of structural panels or rigid ceiling use purlins to brace TC @ 24"oc,BC @ 44"oc. OREGON Wind Member design based on both MWFRS and C&C. (/ �lY 14,2e� t0 Uplifts based on an elevation at or above 1000 ft. *sell Tar Renewal 6/3012020 12/07/2018 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Oregon Truss *IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS 17900 SE Wallace Rd. Trusses require extreme care in fabricating,handlin shipping,installing,and bracing. Refer to and follow the latest edition of BCSI(Building Dayton OR 97114 Component Safety Information,by TPI and SBCA)for safety practices prior to performing these functions. Installers shall provide temporaryry (�)581-8787 Ext bracing per SCSI.Unless noted otherwise,top chord shall have properly attached structural sheathing and bottom chord shall have aprogenyattached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracing installed per BCSI sections B3,B7 or B10, as applicable. Applplates to each face of truss and position as shown above and on the Joint-Details, unless noted otherwise. Refer to ALPINE drawings 160A-Z for standard plate positions. Alpine,a division of ITW Buildin Components Group Inc.,shall not be responsible for any deviation from this drawing,any failure to build the AN my COWAN, truss in conformance with ANSI/TPI 1,or for handling ita shipping,installation and bracing of trussesA seal on this drawing or cover page listing this drawing,indicates acceptance of pro essional engineering responsibility solely for the design shown. The suitability and use of this rawing for any structure is the responsibility of the Building Designer per ANSIITPI 1 Sec.2. 8801 Folsom Blvd.,Suite 101 For more information see this lob's general notes page and these web sites: ALPINE:www.alpineitw.com;TPI: www.tpinst.org;SBCA:www.sbcindustry.com;ICC:www.iccsafe.org Sacramento,CA 95826 • s SEQN:55372 T2 GABL Ply: 1 Job Number: 40 stockOTC Cust:R435 JRef: 1WG04350001 FROM:ER Qty: 10 40 stock OTC DrwNo: 341.18.0858.13703 Truss Label: 40-4 STOCK GE CY / RTT 12/07/2018 777^0"1 2 9"9 27 66��-12 11 5 2 5'6"14 16'8'12 11'6'14 I1 �'p11"8 17'6"14 I 20' I 22'5"� 27'0"8 fIT./'6-1 L. 5"2 32'11"15 91'4-'L1 40 5'6"14 1'1 4'6"13 1d"J,�!'15 477 2'5'2 2'5.2' 47"7 119 5 4'6"13 '462 5'6"14 m5x6 =5X6 =5X6 - 4X4 =4X6 T2 H •4X6= eH0508 �4X4 X4 =2X4 �H0508 G I T3 -2X4 22X4 12 =4X5 "2X4 J =2X4 _ 4 V DYE-2X4 0 • • - KAL L5 m .J4;..,. 1 14- 0 3X6 A O 1/41 AR T S B2 R Q P AS eH1015(B9R) =3X5 =SS0508 5X6 =SS0508 =3X5 =H1015(B9R) =5X8 1 40' 1 10' 10' 10' 10' f• I10' 20' I 30' 40' Loading Criteria(psf) Wind Criteria Snow Criteria(Pg,Pf in PSF) Defl/CSI Criteria ♦Maximum Reactions(lbs) TCLL: 25.00 Wind Std: ASCE 7-10 Pg:25.0 Ct:1.2 CAT:II PP Deflection in loc Lldefl L/# Gravity Non-Gravity TCDL: 7.00 Speed: 120 mph Pf:25.0(specified) Ce:1.0 VERT(LL): 0.677 R 703 240 Loc R+ /R- /Rh /Rw /U /RL BCLL: 0.00 Enclosure:Part.Enc. Lu: - Cs:0.94 VERT(CL):0.904 R 527 180 AR 4673 I- /- /1976 /1509 /323 BCDL: 1.00 Risk Category:II Snow Duration:1.15 HORZ(LL): 0.226 P - - AS 4673 I- I- /1976 /1509 /- EXP:B Kzt:NA HORZ L:0.301 P - - Wind reactions based on MWFRS Des Ld: 33.00 Mean Height:17.96 ft � ) ARWidth=5.5 Min Req5.0 NCBCLL:0.00 Code/Misc Criteria Creep Factor:2.0Brg = TCDL:3.0 psf BldgCode: IBC 2015 Max TC CSI: 0.948 AS Brg Width=5.5 Min Req=5.0 Soffit: 0.00 BCDL:0.6 psf Bearings AR&AS are a rigid surface. Load Duration:1.15 MWFRS Parallel Dist 0 to h/2 TPI Std: 2014 Max BC CSI: 0.996 RepFac:No Max Web CSI:0.891 Members not listed have forces less than 375# Spacing:84.0" C&C Dist a:4.00 ft Maximum Top Chord Forces Per Ply(lbs) Loc.from endwall:Any FT/RT/PT:6(0)/3(0)/1(0) Chords Tens.Comp. Chords Tens. Comp. GCpi:0.55 Plate Type(s): Wind Duration:1.60 HS,WAVE,18SS VIEW Ver:18.02.00.1016.21 A-C 7021-11287 H-I 2652 -4001 Lumber In lieu of purlins on the bottom chord at 44"o/c,the C-D 5465 -8530 I-J 42 -6498 bottom chords of truss(es)may be braced with D-E 5465-8550 J-K 421111 -6498 Top chord 2x6 DF-L 2100f-1.8E:T2,T3 2x6 DF-L purlins at 10'0"o/c maximum spacing and T-brace E-F 4211 -6498 K-L 5465 -8550 1800f-1.8E: blocking: F-G 4228-6338 L-M 6468-10434 Bot chord 2x6 DF-L 2100f-1.8E:B2 2x6 DF-L (T)2X6 DF-L#2 or better continuous reinforcing G-H 2652-4001 M-O 7021 -11287 1 Webs 2x4.8E: member Attach to bottom chord with 16D DF-L Standard:W4 2x4 DF-L 1800f-1.8E: common nails(0.162"x3.5")at 12"o/c. Maximum Bot Chord Forces Per Plylbs :Lt Wedge 2x6 DF-L 1800f-1.8E: (lbs) :Rt Wedge 2x6 DF-L 1800f-1.8E: ri to Chords Tens.Comp. Chords Tens. Comp. Bracing A-T 10525-6345 R-Q 9216 -5433 (a)Continuous lateral restraint,equally spaced on T-S 9216-5431 Q-P 9216 -5433 member. T-""`"'""ion vie" S-R 9216-5431 P-O 10525 -6343 (b)2x4#3 or better"T"reinforcement.80%length of web member.Attach with 16d Box or Gun nails Maximum Web Forces Per Ply(lbs) (0.135"x3.5",min.)@ 6"oc. Webs Tens.Comp. Webs Tens. Comp. Plating Notes C-T 814-1142 R-K 1035 -2158 T-E 1232 -822 K-P 1232 -822 All plates are 1.5X4 except as noted. E-R 1035-2158 P-M 814 -1142 Purlins CO���EO PROFESS' H-R 2136-1340 In lieu of structural panels or rigid ceiling use purlins tiG I N F �q to brace TC @ 24"oc,BC @ 44"oc. (� �� F11 2 Maximum Gable Forces Per Ply(lbs) 83294PE 1, Gables Tens.Comp. Gables Tens. Comp. Wind ir „ow-- D-Y 1188-1796 AE-I 1844 -2360 Member design based on both MWFRS and C&C. V-AA 1382-2078 AF-AJ 1404 -2105 Uplifts based on an elevation at or above 1000 ft. AA-AF 1404-2105 AJ-AL 1382 -2078 Additional Notes OREGON G-AE 1844-2360 AL-L 1188 -1796 Building designer is responsible for lateral forces, 13 `-tidy 14 200`'' C including bracing for horizontal wind forces.Laterally yes ,(0brace end wall and face of truss.Bracing shown or a 18 Tari noted is designed only to restrain members against buckling due to gravity and in-plane wind loads. Renewal 6/30/2020 12/07/2018 **WARNING** READ AND FOLLOW ALL NOTES ON THIS DRAWING! Oregon Truss **IMPORTANT** FURNISH THIS DRAWING TO ALL CONTRACTORS INCLUDING THE INSTALLERS 17900 SE Wallace Rd. Trusses require extreme care in fabricating,handling,shipping,in;talling,and bracing. Refer to and follow the latest edition of BCSI(Building Dayton OR 97114 Component Safety Information,by TPI grid SBCA)TO!.safety practices prior to performing these functions. Installers shall provide temporary (503)561-8767 Ext bracing per BCSI.Unless noted oTherwise,top chord shall have properly attached structural sheathingq and bottom chord shall have a properly attached rigid ceiling. Locations shown for permanent lateral restraint of webs shall have bracingst inalled per BCSI sections B3,67 or B10, as applicable. Applplates to each face of truss and position as shown above and on the JoinfDetails, unless noted otherwise. Defer to ALPINE drawings 160A-Z for standard plate positions. Alpine,a division of ITW Buildingg Components Group Inc.shall not be responsible for any deviation from this drawing,any failure to build the AN mk COWAN, truss in conformance with ANSI/TPI 1,or for handling,shipping,installation and bracing of trussesA seal on this drawing or cover page, listing this drawing indicates acceptance of professional engineering responsibility solely for the design shown. The suitability 8801 Folsom Blvd.,Suite 10" and use of this drawing for any structure is the responsibility of the Building Designer per ANSI/TPI 1 Sec.2. For more information see this job's general notes page and these web sites:ALPINE:www.alpineitw.com;TPI:www.tpinst.org;SBCA: www.sbcindustry.com;ICC:www.iccsafe.org Sacramento,CA 95826 4 H - BRACE DETAIL FOR TRUSSES ATTACHED TO EITHER SIDE OF A 6x_ OR 8x_ POST (B) 2x6 DF—L #2 OR BETTER CONTINUOUS REINFORCING MEMBER, IN A POST—FRAME STRUCTURE, REINFORCING MEMBERS AS SHOWN ATTACH TO EACH TRUSS PLY WITH 10d BOX NAILS (0.128'x3') BELOW MAY BE USED TO ELIMINATE OR MINIMIZE ROWS OF AT 6' O.C. CONTINUOUS LATERAL BRACING. ALTERNATE WEB BRACE, AS AN ALTERNATE TO ONE OR TWO ROWS OF REFER TO ENGINEERED TRUSS DESIGN FOR SPECIFIC PARAMETERS CONTINUOUS LATERAL BRACING SPECIFIED ON A WEB ON THE SUCH AS SPAN, LIVE AND DEAD LOADS, ETC. ENGINEERED DESIGN, APPLY 2x6 OR 2x8 DF—L #2 OR BETTER CONTINUOUS REINFORCING MEMBER, MATCHING SIZE TO GAP BETWEEN TRUSSES. ATTACH FULL—LENGTH BLOCK TO EACH TRUSS PLY WITH 10d BOX NAILS (0.128'x3') AT 6' O.C. BOTTOM CHORD BRACING, SEE ENGINEERED TRUSS DESIGN FOR USE OF THIS DETAIL TO INCREASE SPACING BETWEEN ROWS OF BOTTOM CHORD LATERAL BRACES. APPLY 2x6 OR 2x8 DF—L #2 OR BETTER CONTINUOUS REINFORCING MEMBER, MATCHING SIZE TO GAP BETWEEN TRUSSES. ATTACH TO EACH TRUSS PLY WITH 10d BOX NAILS (0.128'x3') AT 6' O.C. BUTT ENDS OF REINFORCING MEMBERS AT PURLINS ATTACHMENT LOCATIONS. HEEL DETAIL WEB OR BOTTOM CHORD 0 0 r (B) SUPPORT POLES AND CONNECTIONS BY OTHERS. OBLIQUE SECTION VIEW t,T O PRORSS ma/AMONG.READ ATI FOLLOW w1 RITES MI THIS IRAWIIO ppOLtTANTss FURNISH THIS]CAWING TO ON ALL CONTRACTORS=LIA G TRE INSTALLERS. I LL PSF REF H—BRACE a Trusses require esti-me care m inst.,fabricati g,handling, bracing. Rehr to oriel- _(� follow the latest edition rn on of HCS[®Wlarip Canpgnt Safety Infaotlon.by TPI and SHCA)for safety DL PSF DATE 10/01/14 practices pace to powers-rata these functions Installers shall provide teepwary bracing per 9CSL Unless natal otherwise,tap chard shah have property attached structural sheathing and batt.A dined B DL PSF DRWG HBRACE1014 shalt have a property attached swnw setting. Locations own for peat lateral restraint Of webs A(LIR 1 E OWMw etl l b acig instalper HEST sections HH,HT or HIS appltaae. AFIAY plates to fact,face O I\V' shaltof trss and position as shown above antl an the.mint Demi:, otherwise.tefs noted other. . B! LL PSF Refer to...haws 160A-2 far standard puree posltbna OREGON PIpM,a dAsan of Tic Huildmg Conpvan[s Cra�p Inc snail not he responsible for ony deolaaan frog 'IT. LD. PSF AN fRV COHAMNY Yss a•aamgS ony Pasure to trusses the truss h conioreonce aYn ANSIrtPI 1,ar Io-Mooing,shbpkg, lnetasmn a twang ng covSLY 14,10 A vel on p;drawing O cover pope listing the drawing,YeaoaNty acceptance of this Am*, toesnoany s responsibility is etw Far the the whom The sultDer per and 191 of toes awwbq *e 13389 Lakefront Dove far a^Y sYteclere s Yee refpaMsity of the Hlabg Designer ANSI/IPI t Yec.g. e''Tar _ Earth City.MO 03045 Far nate information see Yes Job's general notes page and these warn sites. ALPINE.wseolphMtaconl TPH ww.tpinstargl SHG.rwssbcmtlustry.argiICC.welccfafe dg Renewal 03082020 4L/U/JLU16