Loading...
Plans (17) I 5T Project: -Untitled1 03/18/2019 Prepared By: 03:35PM VALIDITY OF PERMIT RECEIVED THE ACTIVATION OF A L). . , THE ISSUANCE OFA PERMIT SMOKE DETECTOR SHALL BASED ON CONSTRUCTION ACTIVATE A VISIBLE AND i DOCUMENTS AND OTHER APR 4 2019 DATA SHALL NOT PREVENT CITY OF TIGARD AUDIBLE SUPERVISORY THE CODE OFFICIAL FROM BUILDING DIVISION SIGNAL AT A CONSTANTLY REQUIRING THE CORRECTION ATTENDED LOCATION OF ERRCtit. OSSC 105.4 OMSC 606.4.1 Tag Cover Sheet Unit Report Certified Drawing Performance Report OFFICE COP" CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approvcd:� OTC: [ Permit#: Address: 7 y no s imet k Lt, Suite#: By: J Date: - 1 • Packaged Rooftop Builder 1.49p Page 1 of 8 Unit Report For 5T Project: —Untitled1 03/18/2019 Prepared By: 03:35PM Unit Parameters Dimensions(ft. in.)&Weight(lb.)*** Unit Moder 48KCEA06A2A5-0A0A0 Unit Length. 6' 2.375" Unit Size. 06(5 Tons) Unit Width 3' 10.75" Volts-Phase-Hertz' 230-3-60 Unit Height 3'5.375" Heating Type. Gas *•* Total Operating Weight 666 lb Duct Cfg. Vertical Supply/Vertical Return Medium Heat *** Weights and Dimensions are approximate. Weight does Single Stage Compressor Models not include unit packaging. Approximate dimensions are provided primarily for shipping purposes.For exact dimensions and weights,refer to appropriate product data catalog. Lines and Filters Return Air Filter Type. Throwaway Return Air Filter Quantity' 4 Return Air Filter Size 16 x 16 x 2 Unit Configuration Medium Static Option Belt Drive Al/Cu-Al/Cu Base Electromechanical Controls Standard Packaging Warranty Information 1-Year parts(std.) 5-Year compressor parts(std.) 10-Year heat exchanger-Aluminized(std.) No optional warranties were selected. NOTE: Please see Warranty Catalog 500-089 for explanation of policies and ordering methods. Ordering Information Part Number Description Quantity 48KCEA06A2A5-0A0A0 Rooftop Unit 1 Base Unit Medium Static Option Belt Drive None Accessories CRECOMZR020A02 Standard Low Leak Vertical EconoMi$er IV with solid-state controller 1 Packaged Rooftop Builder 1.49p Page 2 of 8 Certified Drawing for 5T Project: -'Untitledl 03/18/2019 Prepared By: 03:35PM NOTES: UNITED P.O.BOY ADDS THIS DOCUMENT[5 THE PROPERTY Df CARRlEI CORPORATION SUBMISSION Of TRUE DRAWINGS OR DOCUMENTS TECHNOLOGIES sluOusE.XT AXD IS DEE IYFRED UPAS TRE EMPRESS CORDITITH TXAT TRE DOES NOT CONSTITUTE PANT PERFORMANCE OR CONTENTS 5ILL ROT or DISCLOSED OR USED WITHOUT CARRIER 1. DIMENSIONS ARE IN INCHES DIMENSIONS UNIT J N 11 PHASE) K f3 PHASE) CARRIER 13221 CORPORATION'S WRITTEN CONSENT. ACCEPTANCE Of CONTRACT. IN I I ARE IN MILLIMETERS. 48KC 04 33 3/8 ,14077,1; 14 7/8 2.f9 CENTER OF GRAVITY [8411 13771 CONNECTION SIZES 33 3/8 14 7/8 18 5/8 4""05 [8471 13771 [4721 A 1 3/8' [351 DIA FIELD POWER SUPPLY HOLE 3.MON,DIRECTION OF AIR FLOW 41 3/8 14 7/8 18 5/8 0 2' [50] DIA POWER SUPPLY KNOCKOUT 48KC 06 [1051] [3771 [472] C 1 3/4' [511 DIA GAUGE ACCESS PLUG D 7/8" I22]DIA FIELD CONTROL WIRING HOLE 33-3/8 [848] E 3/4"-14 NPT CONDENSATE DRAIN F 1/2"-14 NPT GAS CONNECTION G 2 1/2' [641 DIA POWER SUPPLY KNOCK-OUT 32-1/4 ECONOMIZER HOOD 16 1818] (OPTIONAL) [4061 THRU-THE-BASE CHART FILTER ACCESS PANEL4 THESE HOLES REQUIRED FOR USE • (TOOL•LESS) COMP. 1 CONDENSER I CRBTNPWROOIA01, 003601 • ACCESS COIL •PANEL +," •• •• THREADED WIRE REO'D HOLE INR COIL //0\. - E + CONDUIT SIZE USE SIZES(MAX.) ACCESS PANEL I �� `_ W 1/2' ACC. 7/8"122.21 ��i�\ 25-5/8 (2-7/8 ♦ % 1/2' 24Y 7/8"[22.2] Ar y M 16521 NIAIR _ [2771 RETURN Y r 3/4" 1001,003) POWER 1 1/8' [28.1] ',,i •��-1 W11il ] 44 SLI '', �, AIR ZWW (003)1/2' FPT GAS 1 3/16" [30.0] 111171 � "�-�� (3 , . \�\ � I FOR INGSUFORE ONLYE0,8' lFACTORY OPTION, ANDLE 2.5/8—I \ ��'� - FITTINGS FOR ONLY%,Y, S 2 ARE PROVIDED BACK TYP E ALT W SELECT EITHER 3/4'OR I/O' IYP . •W • CONDENSATE - 17-3/4 ` FOR POWER, DEPENDING ON WIRE SIZE CURBI co DRAIN OPENING [451] 10011 PROVIDES 3//'FPT THRU CURB WIDTH I .Y IN OPENING 29-3/e •. SUPPLY 26-1/2 FLANGE 8 FITTING. 18-1/8 I Z AIR [6731 [7/7] SUPPLY [4591 AIR 161118 1461/4 12-1/4 - •• `I � _ 1611] [363] [312] SEE THRU THE 6- 14 BASE CHART W[1571 . i- , 1 1 �_ f --- 3 3/8 12-1/8 �[85] 25 LUE [307] [636] [100] HOOD 18-1/2 11 rc TOP 14701 d-5/8 10-1/2 1-1/4 11181 [2651 (32] • _ ELECTRICAL .. • • DISCONNECT LCATION 'r CONDENSER =_ �1/1 CONTROL BOX • INDOOR BLOWER E STD. I I ILTER COIL =A. ACCESS PANEL ACCESS • CONDENSATE =G• DRAIN• 25-1/B —.. =G J _ 6301 OPTIONAL == - im 16-3/4 I RETURN OUTSIDE I FACTORY —ill- OPTIONAL - „FE f� I'. [d21] I AIR AIR INSTALLED �- 19-1/2 FACTORY F4�• „HANDLE 11-3/8 --SUPPLY AIR— Ay' L�j/ CONVENIENCE r INSTALLED -e L OUTLET -M. I [1681 1494] DISCONNECT O O I I =. O O 2891[1558 I O L ry 539]4 3-3/4 HANDLE -8-3/8 —6-5/8 7 6 (951 46-3/4 30-1/8 [2131 11601 [171] [152] 111871 [7641 26-7/8 7/-3/8 [682] BAROMETRIC [1888] 31-1/4 RELIEF 17931 FLOW LEFT AIRPLY f RETURN FRONT AIR RIGHT SHEET DATE SUPERCEDES 48KC 04-06 SINGLE ZONE ELECTRICAL REV 1 OF 2 09-16-14 - COOLING WITH GAS HEAT 48KC000Z81 Packaged Rooftop Builder 1.49p Page 3 of 8 Certified Drawing for 5T Project: -Untitledl 03/18/2019 Prepared By: 03:35PM OOIE5 9P.Da.ACO,48 STD. UNIT CORNER CORNER CORNER CORNER C.G. HEIGHT C1ACOdNNIDlY PC1OD5ADTCDIEfN0RL1FIINYL'STEE AWEISRD I TIYTBNPOFEE NX CONSENT. ONSENTR. CONTRACT. OENOr 9RCCAXgR9R[ID0IEI1NR 1IW0INHONPYTOXIARCATTHTiAwHREIER SIDRDIMfINSNMIOT ANCCCMOENPSTlTAX1NE1NCEETFa DAPNNPSFRqFOl UNIT WEIGHT WEIGHT(A) WEIGHT(B) WEIGHT(Cl WEIGHT(D) ONOANCY[IEEONIR _ LBS. KG. LBS. NG. LBS. KG. LBS. KG. LBS. KG. X Y 2 48KC 04 490 222 120 54 111 50 125 56 135 61 35 3/4 19081 24 3/4[6281 18 7/8[479] 48KC 05 544 246 130 58 126 57 142 6/ 146 66 36 3/4 19331 24 3/4[6281 18 7/8[4791 48KC 08 597 270 141 84 156 70 158 71 142 84 39 1/8 19931 23 1/2[597] 20 1/8[511] STANDARD UNIT WEIGHT IS WITH LOW GAS HEAT AND WITHOUT PACKAGING. FOR OTHER OPTIONS AND ACCESSORIES, REFER TO THE PRODUCT DATA CATALOG. CORNER A CORNER B 0 • lllll(11111���\� 1: 484848 i • CORNER D L CORNER C X TOP • _ _ - _ • • •o �. �. : oov FRONT SHEET 081E SNPEACEDIS 48KC 04-06 SINGLE ZONE ELECTRICAL REV 20F2 09-16-14 - COOLING WITH GAS HEAT 48KC000281 _ Packaged Rooftop Builder 1.49p Page 4 of 8 Certified Drawing for 5T Project: -'Untitledl 03/18/2019 Prepared By: 03:35PM Service Clearance y% y y * ..0_,..... 0 COS337 LOCATION DIMENSION CONDITION 48-in(1219 mm) •Unit disconnect is mounted on panel A 18-in(457 mm) •No disconnect,convenience outlet option •Recommended serviceclearance 12-in(305 mm) •Minimum clearance 42-in(1067 mm) -Surface behind servicer is grounded(e.g.,metal,masonry wall) 8 36-in(914 mm) -Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special -Check for sources of flue products within 10-ft.of unit fresh air intake hood C 36-in(914 mm) •Side condensate drain is used 18-in(457 mm) •Minimum clearance 48-in(1219 mm) •No flue discharge accessory installed,surface is combustible material 42-in(1067 mm) •Surface behind servicer is grounded(e.g.,metal,masonry wall,another unit) D 36-in(914 mm) •Surface behind servicer is electrically non-conductive(e.g.,wood,fiberglass) Special •Check for adjacent units or building fresh air intakes within 10-ft.of this unit's flue outlet NOTE:Unit not designed to have overhead obstruction.Contact Application Engineering for guidance on any application planning overhead obstruction or vertical clearances. cs i,2-2 Packaged Rooftop Builder 1.49p Page 5 of 8 Performance Summary For 5T Project: —Untitled1 03/18/2019 Prepared By: 03:35PM Part N um ber:48KCEA06A2A5-0A0A0 ARI SEER. 14.10 Base Unit Dimensions Unit Length. 74.4 in Unit Width 46.8 in Unit Height 41.4 in Operating Weight Base Unit Weight 597 lb Medium Heat 9 lb Medium Static Option Belt Drive. 10 lb Accessories Standard Low Leak Vertical EconoMi$er IV with solid-state controller 50 lb Total Operating Weight 666 lb Unit Unit Voltage-Phase-Hertz. 230-3-60 Air Discharge. Vertical Fan Drive Type. Belt Actual Airflow. 2000 CFM Site Altitude. 0 ft Cooling Performance Condenser Entering Air DB. 95.0 F Evaporator Entering Air DB. 80.0 F Evaporator Entering Air WB. 67.0 F Entering Air Enthalpy 31.44 BTU/lb Evaporator Leaving Air DB. 58.6 F Evaporator Leaving Air WB. 57.3 F Evaporator Leaving Air Enthalpy 24.57 BTU/lb Gross Cooling Capacity 61.84 MBH Gross Sensible Capacity. 46.23 MBH Compressor Power Input 5.19 kW Coil Bypass Factor 0.058 Heating Performance Heating Airflow. 2000 CFM Entering Air Temp' 70.0 F Leaving Air Temp. 113.1 F Gas Heating Input Capacity ____ 115.0 MBH Gas Heating Output Capacity 93.0 MBH Temperature Rise 43.1 F Thermal Efficiency(%) 81.0 Supply Fan External Static Pressure. . 0.50 in wg Options/Accessories Static Pressure Economizer 0.12 in wg Total Application Static(ESP + Unit Opts/Acc.). 0.62 in wg Fan RPM- 1248 Fan Power 1.22 BHP NOTE. Selected IFM RPM Range: 1035-1466 Electrical Data Voltage Range. 187-253 Compressor#1 RLA. 15.9 Compressor#1 LRA. 110 Outdoor Fan Motor Qty 1 Packaged Rooftop Builder 1.49p Page 6 of 8 } Performance Summary For 5T Project: -Untitled1 03/18/2019 Prepared By: 03:35PM Outdoor Fan FLA(ea). 1.4 Indoor Fan Motor Type. MED Indoor Fan Motor FLA' 8.3 Combustion Fan Motor FLA(ea). 0.48 Power Supply MCA. 30 Power Supply MOCP(Fuse or HACR). 45 Disconnect Size FLA. 29 Disconnect Size LRA• 185 Electrical Convenience Outlet' None Control Panel SCCR:5kA RMS at Rated Symmetrical Voltage Acoustics Sound Power Levels, db re 10E-12 Watts Discharge Inlet Outdoor 63 Hz 87.5 87.2 87.5 125 Hz 82.7 79.5 82.5 250 Hz 75.5 66.6 76.1 500 Hz 71.2 63.9 73.6 1000 Hz 67.8 63.2 71.3 2000 Hz 62.1 57.3 67.1 4000 Hz 63.9 53.2 64.1 8000 Hz 59.5 45.7 60.0 A-Weighted 74.6 69.2 77.0 Advanced Acoustics tik E 0 161 r N.w Advanced Accoustics Parameters 1. Unit height above ground. 30.0 ft 2. Horizontal distance from unit to receiver 50.0 ft 3. Receiver height above ground. 5.7 ft 4. Height of obstruction. 0.0 ft 5. Horizontal distance from obstruction to receiver 0.0 ft 6. Horizontal distance from unit to obstruction. 0.0 ft Detailed Acoustics Information Octave Band Center Freq. Hz 63 125 250 500 1k 2k 4k 8k Overall A 87.5 82.5 76.1 73.6 71.3 67.1 64.1 60.0 89.2 Lw B 61.3 66.4 67.5 70.4 71.3 68.3 65.1 58.9 76.7 LwA C 55.1 50.1 43.7 41.2 38.9 34.7 31.7 27.6 56.8 Lp D 28.9 34.0 35.1 38.0 38.9 35.9 32.7 26.5 44.3 LpA Packaged Rooftop Builder 1.49p Page 7 of 8 h Performance Summary For 5T Project: —Untitledl 03/18/2019 Prepared By: 03:35PM Legend A Sound Power Levels at Unit's Acoustic Center, Lw B A-Weighted Sound Power Levels at Unit's Acoustic Center, LwA C Sound Pressure Levels at Specific Distance from Unit, Lp D A-Weighted Sound Pressure Levels at Specific Distance from Unit, LpA Calculation methods used in this program are patterned after the ASHRAE Guide; other ASHRAE Publications and the AHRI Acoustical Standards. While a very significant effort has been made to insure the technical accuracy of this program, it is assumed that the user is knowledgeable in the art of system sound estimation and is aware of the tolerances involved in real world acoustical estimation. This program makes certain assumptions as to the dominant sound sources and sound paths which may not always be appropriate to the real system being estimated. Because of this, no assurances can be offered that this software will always generate an accurate sound prediction from user supplied input data. If in doubt about the estimation of expected sound levels in a space, an Acoustical Engineer or a person with sound prediction expertise should be consulted. Fan Curve zo 3 1900RPM ,, 2100RPM 18 1B ' 1� 6 1.4 \ .segHPS \ \ `, , 12 \ L — 9 W i10 �'. 2 d U og i6 _ \ \ (f) 7t](FiPM 3.00=.P \ \111111=16k 200 5JCRPM1 '11PBHP — 1 100 07581-P 02 00 —� . 1 i 1A f ` 4. -I 1 , 1 1 00 03 06 09 12 15 18 21 24 21 33 33 Airflow(CFM-thousands) RPM=1248 BHP=1.22 MaximumRPM=2100 MaximumBHP=2.90 Note:Pleasecontactapplicationengineeringforselectionsoutsidetheshadedregion. SC-System Curve RP-RatedPoint Packaged Rooftop Builder 1.49p Page 8 of 8 co GCS rn0-11 rn Sa Q rn )c. �1Ci5'�Int[iUN�r LAAIDMA23L_L...A4E.-. fi„fT un�tr vtit G4 ic'r' a� r✓ TP-Ne CLtilt 7466 LA-N ma tZtc. LA NE LSA-2.1), bQ