Permit (30) CITY OF TIGARD MASTER PERMIT
111
a ' ' COMMUNITY DEVELOPMENT Permit#: MST2019-00121
Date Issued: 04/17/2019
T I(:A f) 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2439
Parcel: 2S109DB09300
Jurisdiction:
Site address: 13114 SW BLACK WALNUT ST
Subdivision: SUMMIT RIDGE NO.5 Lot: 161
Project: MASLANIK
Project Description: Solar photovoltaic system.
BUILDING
Floor Areas Required Setbacks Required
Stories: 0 Bedrooms: 0 First: 0 sf Basement: 0 sf Left: 0 Parking Spaces: 0
Height: 0 Bathrooms: 0 Second: 0 sf Garage: 0 sf Front: 0 Smoke
Dwelling Units: 0 Third: 0 sf Right: 0 Detectors:
Total: 0 sf Value: $18,900.00 Rear: 0
PLUMBING
Sinks: 0 Water Closets: 0 Washing Mach: 0 Laundry Trays: 0 Rain Drain: 0 Urinals: 0
Lavatories: 0 Dishwashers: 0 Floor Drains: 0 Sewer Lines: 0 SF Rain Storm Sewer: 0
Tubs/Showers: 0 Garbage Disp: 0 Water Heaters: 0 Water Lines: 0 Drains: Catch Basins: 0
Bckflw Prevntr: 0
Footing Drain: 0 Ice Maker: 0 Hose Bib: 0 Backwater Value: 0
Other Fixtures: 0
Drywell-Trench Drain: 0
Other Fixture Units:
MECHANICAL
Fuel Types Air Conditioning: N Vent Fans: 0 Clothes Dryers: 0
Heat Pump: N Hoods: 0 Other Units: 0
Furn<100K: 0 Vents: 0 Woodstoves: 0 Gas Outlets: 0
Furn>=100K: 0
ELECTRICAL
Residential Unit Service Feeder Temp Srvc/Feeders Branch Circuits
1000 sf or less: 0 0-200 amp: 0 0-200 amp: 0 W/Svc or Fdr: 0
Ea add!500 sf: 0 201-400 amp: 0 201-400 amp: 0 W/O Svc/Fdr: 0
Mfd Home/Feeder/Svc: 0 401-600 amp: 0 401-600 amp: 0
601-1000 amp: 0 601+amp-1000v: 0
1000+amp/volt: 0
ELECTRICAL-RESTRICTED ENERGY
SF Residential
Audio&Stereo: N HVAC: N Security Alarm: N Vaccuum System: N Garage Opener: N All
Other: Y Other Description: Roof top PV system 7.56 kW Ecompasing: N
BUILDING INFO
Class of Work: Type of Use: Type of Constr: Occupancy Group: Square Feet
ALT SF VB R-3 0
Owner: Contractor:
MASLANIK,DANIEL&SAMANTHA AURIC SOLAR LLC Required Items and Reports(Conditions)
13114 SW BLACK WALNUT ST 9530 SW TUALATIN-SHERWOOD RD
TIGARD,OR 97224 TUALATIN,OR 97062
PHONE: 541-619-4371 PHONE: 503-716-3055
FAX:
Total Fees: $365.19
This permit is issued subject to the regulations contained in the Tigard Municipal Code, State of OR. Specialty Codes and all other applicable law. All work will
be done in accordance with approved plans. This permit will expire if work is not started within 180 days of issuance, or if work is suspended for more the 180
days. ATTENTION: Oregon law requires you to follow the rules adopted by the Oregon Utility Notification Center. Those rules are set forth in OAR
952-001-0010 through, 52-00 -0090 You may obtain a copy of the ules or direct questions to OUNC by calling 503.232.1987 or 1.800.332.2344.
r
Issued By: .Gj .� Permittee Signature: 'ai .5Z4.,-1(..2 ..= -----..
/ Call 503.639.4175 by 7:00 a.m.for the next available inspection date.
This permit card shall be kept in a conspicuous place on the job site until completion of the project
Approved plans are required on the job site at the time of each inspection.
Building Permit Application
Residential r)r .:' ' !r7I jFOR OFFICE USE ONLY
1
City of Tigard p� Received �j� /
a A p R 1 0 2019 Date/By: y I 1' t ' /� "l/t/�
13125 SW Hall Blvd.,Tigard,OR 97223 ,E E Plan Review
a Phone: 503.718.2439 Fax: 503.598.1960Other Permit:
Date/By: 1 9
-t 1 C;4 R 1) Inspection Line: 503.639.4175 ' y i Date Ready/By: / / is: ® See Page 2 for
Internet: www.tigard-or.gov ; ,,rra ',DIVISION, JN o tried/Method: ! /� Supplemental Information
,y
,., t,.,,,,,•, illi•_ ...... ..:......... illi. •..... ...•,
❑New construction 0 Demolition Permit fees*are based on the value of the work performed.
Indicate the value(rounded to the nearest dollar)of all
0 Addition/alteration/replacement ®Other:Solar PV equipment,materials,labor,overhead,and the profit for the
Cr 8 1 work indicated on this application.
.....
® 1-and 2-family dwelling 0 Commercial/industrial Valuation: $18,900
❑Accessory building 0 Multi-family Number of bedrooms:
❑Master builder 0 Other: Number of bathrooms:
; )fl Total number of floors:
Job site address: 13114 SW Black Walnut St New dwelling area: square feet
City/State/ZIP:Tigard,OR 97224 Garage/carport area: square feet
Suite/bldg./apt.no.: 1 Project name:Maslanik 177199 Covered porch area: square feet
Cross street/directions to job site: `- Deck area: square feet
-/
'] . at K-wl Other structure area: square feet
.n., ATA RC[ t Ku
Subdivision: 1 Lot no.: Permit fees*are based on the value of the work performed.
Tax map/parcel no.: Indicate the value(rounded to the nearest dollar)of all
equipment,materials,labor,overhead,and the profit for the
t i 1 ` o, O r ®l work indicated on this application.
nw itm ..•..c .......-... .. nr .neg. illi., illi, u .:. g..
7.56 kW Rooftop Solar PV Installation Valuation: $
Existing building area: square feet
New building area: square feet
a .e 4, 1 ••,...-� Number of stories:
Name:Samantha Maslanik Type of construction:
Address:13114 SW Black Walnut St Occupancy groups:
City/State/ZIP:Tigard,OR 97224 Existing:
Phone:(541)619-4371 Fax:( ) New:
P rm I ra Z
.. ,..,,illi-m. E ....... •, ,...„�__...., ............... ...........
IR-
......u;-, illi ..reit;,. ,..,�,,, •.t :h. : ..,vw.0^,_ ___._•••.•E
Business name:Auric Solar LLC
Structural plan review fee(or deposit):
Contact name:Mitchell Hampton
FLS plan review fee(if applicable):
Address:9530 SW Tualatin-Sherwood Rd
Total fees due upon application:
City/State/ZIP:Tualatin,OR 97062
Amount received:
Phone:(971)803-1803 Fax::( )
E-mail: tJLT 1 1 at P� .IligtOMN
Commercial and residential prescriptive installation of
p
,:i u:.�. ....• t. .., . ...... ....•,mill,_ .....:.v, ......, roof-top mounted Photo Voltaic Solar Panel System.
Business name:Auric Solar LLC Submit two(2)sets of roof plan with connection details
and fire department access,along with the 2010 Oregon
Address:9530 SW Tualatin-Sherwood Rd Solar Installation Specialty Code checklist.
City/State/ZIP:Tualatin,OR 97062 Permit Fee(includes plan review $180.00
and administrative fees):
Phone:(971)803-1803 Fax:( )
hie(.2a Total
surcharge(12%of permit fee): $21.60
CCB lic.:212831 // Total fee due upon application: $201.60
Authorized signature: "/% � n This permit application expires if a permit is not obtained
/ within 180 days after it has been accepted as complete.
Print name:Mitchell Hampton Date:4/10/2019 *Fee methodology set by Tri-County Building Industry
Service Board.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
w
Building Permit Application Checklist
One- and Two-Family Dwelling FOR OFFICE USE ONLY
" City Tigard Ti d Received • ,:
Date/By: Permit No.:
_ 13125 SW Hall Blvd.,Tigard,OR 97223 Associated permits:
Phone: 503.718.2439 Fax: 503.598.1960
TIGNED
24-Hour Inspection Line: 503.639.4175 ❑ Electrical ❑ Plumbing ❑ Mechanical
Internet: www.tigard-or.gov 0 Other: ,
THE FOLLOWING ITEMS ARE REQUIRED FOR PLAN REVIEW Yes No N/A
1 Land use actions completed. See jurisdiction criteria for concurrent reviews. ❑ ❑ Cl
2 Zoning. Flood plain,solar balance points,seismic soils designation,historic district,etc. ❑ ❑ ❑
3 Verification of approved plat/lot. 0 0 0
4 Fire district approval required. Name of district: 0 ❑ 0
5 Septic system permit or authorization for remodel. Existing system capacity ❑ ❑ ❑
6 Sewer permit. ❑ 0 0
7 Water district approval. ❑ ❑ ❑
8 Soils report. Must carry original applicable stamp and signature on file or with application. 0 ❑ 0
9 Erosion control 0 plan ❑permit required. Include drainage-way protection,silt fence design and location of catch- ❑ ❑ ❑
basin protection,etc.
10 3 Complete sets of legible plans. Must be drawn to scale,showing conformance to applicable local and state ❑ 0 ❑
building codes. Lateral design details and connections must be incorporated into the plans or on a separate full-size
sheet attached to the plans with cross references between plan location and details. Plan review cannot be completed if
copyright violations exist.
11 Site/plot plan drawn to scale. The plan must show lot and building setback dimensions;property corner elevations(if 0 ❑ 0
there is more than a 4-ft.elevation differential,plan must show contour lines at 2-ft.intervals);location of easements
and driveway;footprint of structure(including decks);location of wells/septic systems;utility locations;direction
indicator;lot area;building coverage area;percentage of coverage;impervious area;existing structures on site;and
surface drainage.
12 Foundation plan. Show dimensions,anchor bolts,any hold-downs and reinforcing pads,connection details,vent size ❑ ❑ ❑
and location.
13 Floor plans. Show all dimensions,room identification,window size,location of smoke detectors,water heater, ❑ ❑ ❑
furnace,ventilation fans,plumbing fixtures,balconies and decks 30 inches above grade,etc.
14 Cross section(s)and details. Show all framing-member sizes and spacing such as floor beams,headers,joists,sub- ❑ ❑ ❑
floor,wall construction,roof construction. More than one cross section may be required to clearly portray
construction. Show details of all wall and roof sheathing,roofing,roof slope,ceiling height,siding material,footings
and foundation,stairs,fireplace construction,thermal insulation,etc.
15 Elevation views. Provide elevations for new construction;minimum of two elevations for additions and remodels. 0 ❑ ❑
Exterior elevations must reflect the actual grade if the change in grade is greater than four foot at building envelope.
Full-size sheet addendums showing foundation elevations with cross references are acceptable.
16 Wall bracing(prescriptive path)and/or lateral analysis plans. Must indicate details and locations;for non- ❑ ❑ ❑
prescriptive path analysis provide specifications and calculations to engineering standards.
17 Floor/roof framing. Provide plans for all floors/roof assemblies,indicating member sizing,spacing,and bearing ❑ ❑ ❑
locations. Show attic ventilation.
18 Basement and retaining walls. Provide cross sections and details showing placement of rebar. For engineered 0 ❑ ❑
systems,see item 22,"Engineer's calculations."
19 Beam calculations. Provide two sets of calculations using current code design values for all beams and multiple joists 0 ❑ ❑
over 10 feet long and/or any beam/joist carrying a non-uniform load.
20 Manufactured floor/roof truss design details. ❑ ❑ ❑
21 Energy Code compliance. Identify the prescriptive path or provide calculations. A gas-piping schematic is required ❑ ❑ ❑
for four or more appliances.
22 Engineer's calculations. When required or provided,(i.e.,shear wall,roof truss)shall be stamped by an engineer or ❑ ❑ ❑
architect licensed in Ore:on and shall be shown to be a..licable to the .ro'ect under review.
JURISDICTIONAL SPECIFICS
23 Three(3)site plans are required for Item 11 above. Site plans must be 8-1/2"x 11"or 11"x 17". ❑ ❑ ❑
24 Two(2)sets each are required for Items 16, 19,20 and 22 above. ❑ ❑ ❑
25 Building plans shall not contain red lines or tape-ons. "Mirrored"building plans will not be accepted. ❑ ❑ ❑
26 "Reversed"building plans must meet criteria outlined in the Permit&System Development Fees document. 0 ❑ 0
27 "Drawn to scale"indicates standard architect or engineer scale. ❑ ❑ ❑
28 Site plan to include tree size,type and location per approved project street tree plan(if applicable),and City of Tigard ❑ 0 ❑
Street Tree List.
29 Site plan to include trees and tree protection measures as required by conditions of approval. Tree locations,driplines, ❑ ❑ ❑
and protection measures must be drawn to scale and must include the project arborist's signature of approval.
30 A Clean Water Services'Sensitive Area Pre-Screening Site Assessment form is required for all building additions, 0 ❑ ❑
including decks,patio covers(over non-impervious surface)and accessory structures to existing residential dwellings
on a lot of record approved prior to September 9, 1995.
I:\Building\Permits\BUP-RESPermitApp.doc 02/24/2011 440-4613T(11/02/COM/WEB)
, 1
Electrical Permit Application REc 7 77 - 1014 OFFICE: t su:()Ni.‘
III
City of Tigard Received
EVIZEIN22rM
• 13125 SW Hall Blvd.,Tigard,OR 97223 APR 1 0 2019 Zltiel:23e1iew
ll Phone: 503.718.2439 Fax: 503.598.1960 „,,_ Date/B : Related Permit#:
Inspection Line: 503.639.4175 '--, ) l' .• • .:,r -Ready Date/By: Juns: 0 See Page 2 for
TI GA RD
- Internet: www.tigard-or.gov BUILDIN-Q L;i.r:;': Notified/Method: Supplemental Information
NUSigaMeiliglirgalPliiiic: 2ZiTaldigatzitiaMPIireggiliT 11201,44WW:il; 0:TriT7';79450014aljam
0 New construction 0 Addition/alteration/replacement- Please check all that apply(submit a,sets of plans w/items checked):
E Service or feeder 400 amps or more i: Building over three stories.
0 Demolition ISI Other:Solar PV Array where the available fault current 0 Marinas and boatyards
- y' st” tj' exceeds 10,000 amps at 150 volts or 0 Floating buildings.
IZI 1-and 2-family dwelling 0 Commercial/industrial 0 Accessory building less to ground,or exceeds 14,000 0 Commercial-use agncultural
amps for all other installations, buildings.
0 Multi-family 0 Master builder 0 Other: 0 Fire pump. 0 Installation of 150 KVA or
111•1111MatinfEltririrle;Vilurioinlitinftlain 00 Emergency system' larger separately derived
Job#: 177199 Job site address: 13114 SW Black Walnut St _AI:: of new motor load of 0 system.
Job
"1_2,,"1-3",o Six or more residential units, occupancy.
or more.
City/State/ZIP:Tigard,OR 97224 0 Health-care facilities 0 Recreational vehicle parks
Suite/bldg./apt.#: Project name:Samantha Maslanik 177199 0 Hazardous locations. 0 Supply voltage for more than
Q Service or feeder 600 amps or more. 600 volts nominal,
SI.., „..
Cross street/directions to job site: 31,11110211.1140 :::nlinIMINIIIRM
I *
I Each f
Description
f Qty. - i'ot;i
New residential single-or multi-family dwelling unit.
Subdivision: Lot#: Includes attached garage.
1,000 sq.ft.or less 168.54 4
Tax map/parcel#:
Ea.add'l 500 sq.ft.or portion 33.92 1
75.00 2
7.56 kW rooftop Solar PV Array (with above sq.ft.)
Limited energy,multi-family
75.00 2
residential(with above sq.ft.)
11,111.1 ,7***Pir::ErEITHENINEMAINFISIOWAWIMEIN ISI:ii•Iveilveasblorr tneedreTTs installation,alteration,and/or relocation
Name:Samantha Maslanik 200 amps or less 100.70 2
Address:13114 SW Black Walnut St 201 amps to 400 amps 133.56 2
401 amps to 600 amps 200.34 2
City/State/ZIP:Tigard,OR 97224
601 amps to 1,000 amps 301.04 2
Phone:(541)6194371 Fax:( ) Over 1,000 amps or volts 552.26 2
Temporary services or feeders installation,alteration,and/or
Email: relocation
Owner installation:This installation is being made on property that I own which is not 200 amps or less 59.36 1
intended for sale,lease,rent,or exchange,according to ORS 447,449,670,and 701. 201 amps to 400 amps 125.08 2
Owner signature: Date: 401 amps to 599 amps 168.54 2
1,51,111[68: 71;1,111111111111111,latik:0055 *11601 1/3‘7:1;ocrill;:auniCh itIcett7t's alteration,ior extension,
per panel
Business name:Auric Solar LLC above service or feeder fee,
7.42 2
each branch circuit
Contact name:Mitchell Hampton B.Fee for branch circuits without
service or feeder
56.18 2
first 1
Address:9530 SW Tualatin-Sherwood Rd 56.18
branch circuit City/State/ZIP:Tualtain,OR 97062 Each add'l branch circuit 7.42 2
Miscellaneous(service or feeder not included)
Phone:(971)803-1803 Fax: :( ) Each manufactured or modular
67.84 2
dwelling,service and/or feeder
Email:mitchell.hampton@auricenergy.com Reconnect only
67.84 2
MINEIVISMIESSEEYnn'RilillegilINIMPIMEM Pump or irrigation circle 67.84 2
Business name:Auric Solar LLC Sign or outline lighting 67.84 2
Signal circuit(s)or limited-energy 0 See Page 2
2
Address:2310 S 1300 W
Each additional inspection over allowable in any of the above
City/State/ZIP:Salt Lake City,UT
Additional inspection(1 hr min) 66.25/hr
Phone:(503)716-3055 Fax:( ) Investigation(1 hr min) 90.00/hr
Industrial plant(1 hr min) 78.18/hr
Email:rob.smith@auricsolar.com
Inspections for which no fee is 90.00/hr
CCB Lic.: 212831 Electrical Lic.: C1243 Suprv.Lic.: 6122S , pially Jisted('/hr min),,
ifilliatikrANIg*:3.,:tiat F: 211111ME
Suprv.Electrician signature,required:
C...,.._...
Subtotal:
Print name: Thaniel Bishop Date: 4/10/2019
0 Plan Review Required(25%of permit fee):
State surcharge(12%of permit fee):
Authorized signature: c1640 /44r TOTAL PERMIT FEE:
This permit application expires if a permit is not obtained within 180
Print name: Rob Smith Date: 4/10/2019 days after it has been accepted as complete.
Electrical Permit Application—City of Tigard
Page 2—Supplemental Information
Limited Energy Permit Fees: Renewable Energy Permit Fees:
.. . ��' +`� '* "„ .aa , ..... .,,. rm'.a. 173- a �, i ,wai�
Description Qty. Each Total
Fee for all residential systems combined: $75.00 Renewable electrical energy systems:
Check Type of Work Involved: s kva or less 100.70 2
5.01 to 15 kva 1 133.56 133.56 2
❑ Audio and Stereo Systems* 15.01 to 25 kva 200.34 2
Wind generation systems in excess of 25 kva:
❑ Burglar Alarm 25.01 to 50 kva 301.04 2
50.01 to 100 kva 552.26 2
❑ Garage Door Opener* >100 kva(fee in accordance
with OAR 918-309-0040) 552.26 2
❑ Heating, Ventilation and Air Conditioning Solar generation systems in excess of 25 kva:
System*
Each additional kva over 25 7.42 3
❑ Vacuum Systems* >100 kva-no additional charge 0.0 3
Each additional inspection over allowable in any of the above:
❑ Other: Each additional inspection is 66.25/hr 1
charged at an hourly(1 hr min)
Inspections for which no fee is 90.00/hr
specifically listed(%hr mm)
Subtotal(Enter on Page
Fee for each commercial system: $75.00 1):
* Number of inspections allowed per permit.
(SEE OAR 918-309-0000)
Check Type of Work Involved:
❑ Audio and Stereo Systems
❑ Boiler Controls
❑ Clock Systems
❑ Data Telecommunication Installation
❑ Fire Alarm Installation
❑ HVAC
❑ Instrumentation
❑ Intercom and Paging Systems
❑ Landscape Irrigation Control*
❑ Medical
❑ Nurse Calls
❑ Outdoor Landscape Lighting*
❑ Protective Signaling
❑ Other:
Total number of commercial systems:
*No licenses are required. Licenses are required for all
other installations
I:\Building\Permits\ELC_PermitApp_ELR_ERE.doe Rev 06/17/2015
S-
ICity of Tigard � {
., '� Building Division �{.�,--7,1117D
. 13125 SW Hall Blvd,Tigard, OR 97223
Phone: 503.718.2439 Fax: 503.598.1960 APR 10.2019
TjI G A R D Inspection Line: 503.639.4175
www.tigard-or.gov
2010 Oregon Solar Installation Specialty Code
Check List for Prescriptive Installation of Roof-Mounted
PhotoVoltaic Solar Panel System
Property Information
Installation Address: 13114 SW Black Walnut St
City: Beaverton Zip: 97224
Owner's Name: Samantha Maslanik Date: 4/10/2019
Contractor's Name: Auric Solar LLC CCB #: 212831
Design Parameters of the Property/Structure
If"Yes", does not
Flood Hazard Is the installation El Yes qualify for the
Area Located in a flood prescriptive path, follow
plain/flood way? a No OSSC or ORSC for
design requirements.
Wind Exposure Is the wind exposure ® Yes If"Yes", qualifies for
"C" or less? ❑ No the prescriptive path.
Installations on detached Is the Ground Snow
single/two-family Load 70 psf or less?
dwelling/single/two- If"Yes", qualifies for
family townhomes ® Yes the prescriptive path.
and/or their accessory
Ground structures. ❑ No
Snow Load Is the Ground Snow
Installations on all Load 50 psf or less?
structures other than If"Yes", qualifies for
® Yes the prescriptive path.
above
❑ No
1
I:/Building/Forms/Photo Voltaic-Checklist.docx
Is the construction
material wood and does ® Yes
Type of If"Yes", qualifies for
the construction qualify
Construction as "conventional light ElNo the prescriptive path.
frame" construction?
Is the spacing 24 inches
or less?
Pre-engineered trusses. ® Yes
If"Yes", qualifies for
the prescriptive path.
❑ No
Roof framing
members Is the spacing 24 inches
or less?
Nominal lumber. If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Is the combined weight ® Yes
of the PV modules and If"Yes", qualifies for
racking less than or ❑ No the prescriptive path.
Solar equal to 4.5 psf?
installation Is the solar installation
layout in accordance ® Yes
with Section 305.4(3) of If"Yes", qualifies for
the 2010 Oregon Solar ❑ No the prescriptive path.
Code?
❑ Metal
Single layer If roofing material is
Roofing Check the type of ® of wood one of the three types
material roofing material shingle/shake checked, qualifies for
Max. two layers the prescriptive path.
❑ of composition
shingle.
Is the roof mounted ® Yes
Connections of solar assembly
the solar assembly connected to roof If"Yes", qualifies for
❑ No the prescriptive path.
to the roof framing or blocking
directly?
2
I:/Building/Forms/PhotoVoltaic-Checklist.docx
❑ Yes If"Yes", qualifies for
Is the gauge 26 or less? ❑ No the prescriptive path.
115 lbs for 60 inch
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Minimum Uplift rating
of Clamps? 75 lbs for 48 inches
spacing or less?
If"Yes", qualifies for
❑ Yes the prescriptive path.
❑ No
Attachment of
roof mounted Minimum 24 inches If the spacing falls
solar systems Spacing of clamps? within 24 inches and 60
directlyto inches inches, qualifies for the
Maximum 60 inches prescriptive path.
standing seam
metal panels Width of roofing If the width of the panel
panels? 18 inches or less is less than 18 inches,
inches qualifies for the
prescriptive path.
Minimum#10 at 24
inches o/c?
Size and spacing of If"Yes", qualifies for
fastener? 111 Yes the prescriptive path.
❑ No
Is the roof decking of
WSP min. 'A"thickness, ❑ Yes
decking connected to If"Yes", qualifies for
framing members ❑ No the prescriptive path.
w/min. 8d nails @
6"/12"o/c?
Is the height less than or
Maximum 18 inches equal to 18 inches?
Height of the from the top of the If"Yes", qualifies for
solar modules module to the roof ® Yes the prescriptive path.
surface. ❑ No
3
I:/Building/Forms/PhotoVoltaic-Checklist.docx
Submittal Documents required for Prescriptive Installations
Show the location of the PV system in relation to buildings, structures,
property lines, and, as applicable, flood hazard areas.
Site Plan Details must be clear and easy to read.
Minimum size of the plan is 8.5 x 11 inches.
Attach a simple structural plan showing the roof framing(rafter size, type, and
spacing) and PV module system racking attachment.
System must be shown in sufficient detail and clarity to assess whether it
Structural Plan meets the prescriptive construction requirements as listed earlier above in the
matrix.
Minimum size of the plan is 8.5 x 11 inches.
PV Modules
Manufacturer: REC
Model Number: 315NP 315W Modules
Listing Agency: UL 1703
4
I:/Building/Fonns/PhotoVoltaic-Checklist.docx
City of Tigard
Tel: 503.718.2439
Location: Inspection Date:
13114 SW BLACK WALNUT ST, TIGARD,
OR, 97224
Record Type: Record ID:
Residential - Master Permit MST2019-00121
Inspection Type: Inspector:
199 Electrical final David Young
Result:
PASS
Comments:
Violation Summary:
Inspector Contractor
City of Tigard
Tel: 503.718.2439
Location: Inspection Date:
13114 SW BLACK WALNUT ST, TIGARD,
OR, 97224
Record Type: Record ID:
Residential - Master Permit MST2019-00121
Inspection Type: Inspector:
299 Final inspection David Young
Result:
PASS - NoCofO
Comments:
Violation Summary:
Inspector Contractor