Plans (89) iregon Heating" & Air Conditioning RECEIVED Pioneer Weatherproofing 14830 SW 72nd Ave MAR 14 2019 Tigard, OR 97224 CITY OF TIGARD BUILDING DIVISION Scope of Work Oregon Heating and Air Conditioning will perform the following scope of work: 1. Provide and install (1) 2 ton fan coil with 10KW strip heat. 2. Provide and install (1) 2 ton heat pump on i€0OF 3. Ducting and air distribution as drawn. Equipment Schedule AHI- Trane TEM4A0B24S21SB- 2 ton 208/1/60, 45MCA, 45 MOCP. 32,800 BTU heating through strip heat, 24,000 BTU heating through heat pump, 24,000 BTU cooling. HPI- Trane 4TWR4024A1000A- 2 ton. 208/1/60, 14 MCA, 24 MOCP. 24,000 Btu cooling, 14 SEER. Mechanical General Notes: 1. Cooling equipment does not exceed the load of the calculated requirement. 2. All steel ducting will be 26 ga minimum galvanized. Flex per Mfg. 3. Heating and cooling ducting to be designed to not exceed 0.5 wc positive(supply)and 0.5 wc negative(return). 4. Provide programmable thermostat. 5 degree deadband minimum. 7 day. Microprocessor. Set program for night energy savings. 5. Seal ducting with UL listed mastic or mastic tape. 6. Fan motor does not exceed allowable, first available above BHP. 7. Max leakage rate of OSA or exhaust dampers to be 4 cfm/sft @ 1.0 sp. 8. Provide 0 and M to building owner. OFFICE COPv CITY OF TIGARD REVIEWED FOR CODE COMPLIANCE Approved I OTC: M Permit #: r ec an 19 - no 19a Address: ) no w a ryve._ Suite #: OHAC By: Date: 9. Jo . ) q CCB # 137653 Oregon Heating & Air Conditioning, LLC 'o on_xoa s ; , aa.Condhtomns ®v.. PHONE NUMBER FAX NUMBER OPERATIONS CONTRACTOR LICENSE 503-691-9699 503-691-8556 19300 SW 115th Ave Oregon CCB 137653 1-800-Furnace Tualatin,OR 97062 WA OREGOHC85102 www.oregonheating.65m 0-4 z.�l� iia ipo cp-4. b, ,..„.I, .... lOw L �7c 1� �� PY � at r;'' 4 "t4 • P.:, I 11-0/t) F t L7`t�,i l I N iet .‘ e i ti ix Ir ? O c tr.rt° 18 a I Q. iTi • .fri:, ... -C..... { „®A) 001:1,L VI d •< xi' 4 PP) Ventilation Reauiren encs-based on 2014 OMSC table 403.3 AH1 single zone retail 644 eft breathable zone Persons-5 cfm X 10p/544sft=55 cfm C I t". 1 e i ti PJ Area-0..Oc m m/aft= 55 cfm Approved gr ��iVbz=55 Ez=0.8(supply and return in ceiling) M If voz=to cfm Date: LA Initials: RTU3- SA=800 cfm t' 'L RA=730 cfm HAC OSA=70 cfm .-- CCB ## 137653 Pioneer Waterproofing 1480 SW 72"d Ave Tigard, OR 97224 I d I Submittal 2 Ton Convertible Air Handler TEM4A0B24S21 SB 44000000- [Iv • • • • ;2 TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. January 2018 TEM4A0B24-SUB-IC-EN 40 Ingersoll Rand Outline Drawing 21.13 1.00 12.15 -I 7.98 MINIMUM UNIT CLEARANCE TABLE 100 � SERVICE ��_ CLEARANCE (RECOMMENDED) SIDES 2' FRONT 21' li Ill 01.38 BACK 0' BC INLET DUCT I' OUTLET DUCT N/A C'.�'I m" NOTE:THIS UNIT IS APPROVED FOR INSTALLATION "MI • 2 59 5.03 CLEARANCES AS STA ED ONTH UR NI ATING N MEPLATE 1.001 2.13 r' 02.00 2.13r 2.13 �{ t 93.88 2.11 t O i ---. •• 5.15 INe I I 6.88 P I o 02.00 01.38 7 A 0150 TIP 1.15 P e H .1I 6 f 6 i6 a LJ ® e I\. 17'2 + C ) 1.33- .81 18.75 1.12 a 3.69 a f 1.16 1� 2 PLCS .81 l 1I I .38 a iL 2.I5 L -E 77 -F--- ..1 D , .87 J PRODUCT DIMENSIONS Air Handler Model A B C D E F H Flow Gas Line Control Braze TEM4A0B24521SB 45.02 18.50 16.50 16.75 4.68 7.33 18.34 TXV 3/4 All dimensions are in inches 2 TE M4A0 B24-SUB-1 C-E N Product Specifications MODEL TEM4AOB24S21SB Coupling or Conn.Size— 3/4 in.Gas RATED VOLTS/PH/HZ 208-230/1/60 Coupling or Conn.Size— 3/8 RATINGS(a) See O.D.Specifications in.Liq. INDOOR COIL—Type Plate Fin DIMENSIONS H x W x D Rows—F.P.I. 3-14 Crated(In.) 46 x 21 x 24 Face Area(sq.ft.) 4.37 Uncrated 45-1/8 x 18-1/2 x 21-1/8 Tube Size(in.) 3/8 WEIGHT Refrigerant Control TXV Shipping(Lbs.)/Net(Lbs.) 116/110 Drain Conn.Size(in.)(b) 3/4 NPT ia) These Air Handlers are A.H.R.I certified with various Split System Air Conditioners and Heat Pumps(AHRI STANDARD 210/240).Refer to DUCT CONNECTIONS See Outline Drawing the Split System Outdoor Unit Product Data Guides for performance data. INDOOR FAN—Type Centrifugal (b) 3/4"Male Plastic Pipe(Ref:ASTM 1785-76) (c) Remote filter required. Diameter-Width(In.) 11 X 6 No.Used 1 Minimum Airflow CFM Drive-No.Speeds Direct-3 TEM4AOB24S21SB CFM vs.in.w.g. See Fan Performance Table Heater Minimum Heat Speed Tap No.Motors—H.P. 1-1/5 With Heat Without Heat Pump Pump I Motor Speed R.P.M. 1075 BAYHTR1504BRK, Volts/Ph/Hz 208-230/1/60 BAYHTR1504LUG, Med Low BAYHTR1505BRK, F.L.Amps 1.2 BAYHTR1505LUG FILTER BAYHTR1508BRK, BAYHTR1508LUG, Filter Furnished?() No BAYHTR1510BRK, Med Low BAYHTR151OLUG, REFRIGERANT R-410A BAYHTR351OLUG Ref.Line Connections Brazed TEM4AOB24-SUB-1 C-EN 3 Heater Pressure Drop Table TEM Air Handler Models Number of Racks Heater Racks Airflow 1 2 3 4 Heater Model No.of Racks CFM Air Pressure Drop-Inches W.G. BAYHTR1504 1 1800 0.02 0.04 0.06 0.14 BAYHTR1505 1 1700 0.02 0.04 0.06 0.14 BAYHTR1508 2 1600 0.02 0.04 0.06 0.13 BAYHTR1510 2 1500 0.02 0.04 0.06 0.12 BAYHTR3510 3 1400 0.02 0.04 0.06 0.12 BAYHTR1515 3 1300 0.02 0.04 0.05 0.11 BAYHTR1517 3 1200 0.01 0.04 0.05 0.10 BAYHTR3515 3 1100 0.01 0.03 0.05 0.09 BAYHTR3517 3 1000 0.01 0.03 0.04 0.09 BAYHTR1519 4 900 0.01 0.03 0.04 0.08 BAYHTR1520 4 800 0.01 0.03 BAYHTR1521 4 700 0.01 0.02 BAYHTR1525 4 600 0.01 0.02 4 TEM4A0B24-SUB-1 C-EN Performance and Electrical Data 1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters. 2. Heater model numbers may have additional suffix digits. Table 1. Air Flow Performance TEM4AOB24S21SB(a) EXTERNAL STATIC AIRFLOW (in w.g) Speed Taps-230 VOLTS Speed Taps-208 VOLTS High Med Low t High Med Low t 0.1 1094 927 773 1052 849 658 0.2 1032 880 735 990 807 624 0.3 955 818 678 915 750 578 0.4 864 739 601 826 679 518 I 0.5 759 645 505 723 591 441 0.6 639 534 389 606 490 0.7 505 408 476 374 1. Values are with wet coil,no filter,and no heaters 2. CFM Correction for dry coil=Add 3% 3. t=Factory setting (a) For TEM4A0B24S21SB,the recommended speed tap is medium at 0.4"external static pressure. Table 2. Electrical Data TEM4AOB24S21SB 240 Volt 208 Volt No.of Heater Model No. Circuits/ Capacity Heater Minimum Maximum Capacity Heater Minimum Maximum Phases Amps per Circuit Overload Amps per Circuit Overload kW BTUH Circuit Ampacity Protection kW BTUH Circuit Ampacity Protection No Heater 1.2* 2 15 1.2* 2 15 BAYHTR1504BRK 1/1 3.84 13100 16.0 22 25 2.88 9800 13.8 19 20 BAYHTR1504LUG BAYHTR1505BRK 1/1 4.80 16400 20.0 27 30 3.60 12300 17.3 23 25 BAYHTR1505LUG BAYHTR1508BRK 1/1 7.68 26200 32.0 42 45 5.76 19700 27.7 36 40 BAYHTR1508LUG BAYHTR1510BRK 1/1 9.60 32800 40.0 52 60 7.20 24600 34.6 45 45 BAYHTR1510LUG BAYHTR3510LUG 1/3 9.60 32800 23.1 30 30 7.20 24600 20.0 26 30 *=Motor Amps TE M4A0B24-SUB-1 C-E N 5 Features and Benefits • Painted metal cabinet with captured foil face • Draw Through Design insulation • Horizontal Drain pan • 2%or less air leakage • Single Color • R-4.2 Insulating Value • Fused 24V Power • Multi-Position UP/Down Flow,Horizontal Left/Right • 3 year warranty • ALL Aluminum Coil with Enhanced Patented Coil • 10-year warranty registered Fin • Optional extended warranty available • Electric Heaters with polarized plug connections (sold as accessory) Important:Condensate management kit is required for • R-410A Thermal Expansion Valve all 5 ton air handler models installed in • ECM Motor(3.5—5 Ton Models) down flow applications. • Low Voltage Pigtail Connections 6 TEM4A0B24-SUB-1 C-EN (ITA)ingersoii Rand® Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car®, Ingersoll Rand®, Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings;transport and protect food and perishables;and increase industrial productivity and efficiency.We are a global business committed to a world of sustainable progress and enduring results. Club Car (10 Ingersoll Rand N THERMO KING TRANE° ingersollrand.com ETA us Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. TEM4A0B24-SUB-1C-EN 09 Jan 2018 Supersedes TEM4A0B24-SUB-1B-EN (August 2017) ©2014 Ingersoll Rand , 1 0 TRANE • Submittal .,, Split System Heat Pump Y 4TWR4024G 1000A 11111101111111111111111.177,- �� _moi Note:"Graphics in this document are for representation only.Actual model may differ in appearance." TAG: A SAFETY WARNING Only qualified personnel should install and service the equipment.The installation,starting up,and servicing of heating,ventilating,and air-conditioning equipment can be hazardous and requires specific knowledge and training.Improperly installed,adjusted or altered equipment by an unqualified person could result in death or serious injury.When working on the equipment,observe all precautions in the literature and on the tags,stickers,and labels that are attached to the equipment. March 2016 4TWR4024G-SUB-IA-EN (ffi Ingersoll Rand . • . .. 0 TRANS° B • 4 Wililifil C c.hqNii(,t- ��' t� I SERVICE PANEL I — ll��[�l�����ELECTRICAL AND REFRIGERANT \OcWk,t,,, ,hi , ��'i; '- I '`"II l COMPONENT CLEARANCES `��`,' ````� 4, ♦ A.#4%���% PER PREVAILING CODES. /\.' •<•.-.1;(::' �j����4 / / TOP DISCHARGE AREA SHOULD BE UNRESTRICTED FOR AT LEAST 1524 15 FEET) ABOVE UNIT. UNIT SHOULD BE PLACED SO ROOF RUN-OFF WATER DOES NOT POUR DIRECTLY ON UNIT, AND SHOULD BE AT LEAST 305 112') FROM WALL AND ALL SURROUNDING SHRUBBERY ON TWO SIDES. OTHER TWO SIDES UNRESTRICTED. R- KNI IIi - -�iE 11i ELECTRICAL SERVICE PANE II 25 (I) IIII A lip 1I 22.2 (7/8) DIA. HOLE ii1II &__________LOW VOLTAGE 28.6 (I-1/81 DIA. N.O. WITH 22.2 17/8) DIA. HOLE IN CONTROL BOX BOTTOM FOR ELECTRICALPOWER SUPPLY H F ..ii . .. Aiui.uuw- lwu J I 8.0. FOR ALTERNATE B ELECTRICAL ROUTING LIQUID LINE SERVICE VALVE, 'E' I.D. FEMALE BRAZE CONNECTION WITH I/4' SAE GAS LINE 1/4 TURN BALL SERVICE VALVE, "D' FLARE PRESSURE TAP FITTINGS. I.D. FEMALE BRAZED CONNECTION WITH 1/4" SAE FLARE PRESSURE TAP FITTING. Model Base A B C D E F G H 3 K • 4TWR4024G 3 730 829 756 3/4 3/8 127 76 197 60 508 (28-3/4) (32-5/8) (29-3/4) (5) (3) (7-3/4) (2-3/8) (20) SOUND POWER LEVEL Model A-Weighted Sound Full Octave Sound Power[dB] • Power Level[dB(A)] 63 Hz* 125 Hz 250 Hz 500 Hz 1000 Hz 2000 Hz 4000 Hz 8000 Hz 4TWR4024G 71 77 72 68 68 69 60 53 47 Note:Rated in accordance with AHRI Standard 270-2008*For reference only. • 2 4TWR4024G-SUB-1A-EN • TRANS' Product Specifications OUTDOOR UNIT(a)(b) 4TWR4024G1000A (a) Certified in accordance with the Air-Source Unitary Air-conditioner POWER CONNS.—V/PH/HZ(r) 208/230/1/60 Equipment certification program,which is based on AHRI standard 210/240. MIN.BRCH.CIR.AMPACITY 14 (b) Rated in accordance with AHRI standard 270. BR.CIR.PROT.RTG.—MAX.(AMPS) 25 (c) Calculated in accordance with Natl.Elec.Codes.Use only HACR circuit breakers or fuses. COMPRESSOR CLIMATUFF®-SCROLL (d) This value shown for compressor RLA on the unit nameplate and on NO.USED—NO.STAGES 1—1 this specification sheet is used to compute minimum branch circuit ampacity and max.fuse size.The value shown is the branch circuit VOLTS/PH/HZ 208/230/1/60 selection current. R.L.AMPS(d)—L.R.AMPS 10.9—62.9 (e) No means no start components.Yes means quick start kit components.PTC means positive temperature coefficient starter. FACTORY INSTALLED Optional kit shown. (f) Standard Air—Dry Coil—Outdoor START COMPONENTS(e) YES (9) This value approximate.For more precise value see unit nameplate. INSULATION/SOUND BLANKET NO (h) Reference the outdoor unit ship-with literature for refrigerant piping COMPRESSOR HEAT NO length and lift guidelines.Reference the refrigerant piping software pub#32-3312-xx or refrigerant piping application guide SS- OUTDOOR FAN PROPELLER APG006-xx for long line sets or specialty applications(xx denotes DIA.(IN.)—NO.USED 23—1 latest revision). (0 Trane outdoor condensing units are factory charged with the system TYPE DRIVE—NO.SPEEDS DIRECT—1 charge required for the outdoor condensing unit and 15 feet of tested CFM @ 0.0 IN.W.G.(9) 2675 connecting lines.If connecting line length exceeds 15 feet,then final refrigerant charge adjustment is necessary.Each additional foot over NO.MOTORS—HP 1—1/8 15 feet requires 0.6 ozs of refrigerant.See the Installer's Guide for full charging instructions. MOTOR SPEED R.P.M. 850 VOLTS/PH/HZ 208/230/1/60 F.L.AMPS 0.64 OUTDOOR COIL—TYPE SPINE FINT° ROWS—F.P.I. 1-24 FACE AREA(SQ.FT.) 16.3 TUBE SIZE(IN.) 3/8 REFRIGERANT CONTROL EXPANSION VALVE REFRIGERANT LBS.—R-410A(O.D.UNIT)(9) 6 LBS.,2 OZ FACTORY SUPPLIED YES LINE SIZE—IN.O.D.GAS(h)(I) 3/4 LINE SIZE—IN.O.D.LIQ. 3/8 CHARGING SPECIFICATIONS SUBCOOLING 10°F DIMENSIONS H X W X D CRATED(IN.) 34 x 33 x 30.1 WEIGHT SHIPPING(LBS.) 191 NET(LBS.) 163 4TWR4024G-SUB-1 A-EN 3 eTRINE Mechanical Specification Options General Compressor The Outdoor Units are fully charged from the factory The compressor features internal over temperature, for up to 15 feet of piping.This unit is designed to pressure protection and total dipped hermetic motor. operate at outdoor ambient temperatures as high as Other features include:Centrifugal oil pump and low 115°F Cooling capacities are matched with a wide vibration and noise. selection of air handlers and furnace coils that are AHRI Condenser Coil certified.The unit is certified to UL 1995. Exterior is designed for outdoor application. The outdoor coil provides low airflow resistance and efficient heat transfer.The coil is protected on all four Casing sides by louvered panels. Unit casing is constructed of heavy gauge,galvanized Low Ambient Cooling steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel.The As manufactured,this system has a cooling capacity to corner panels are prepainted.All panels are subjected 55°F The addition of an evaporator defrost control to our 1,000 hour salt spray test.The base is made of a permits operation to 40°F.The addition of an CMBP-G30 weatherproof material to resist corrosion. evaporator defrost control with TXV permits low ambient cooling to 30°F Refrigerant Controls Thermostats—Cooling only and heat/cooling(manual Refrigeration system controls include condenser fan, and automatic change over).Sub-base to match compressor contactor and high pressure switch. High thermostat and locking thermostat cover. and low pressure controls are inherent to the compressor.A factory supplied liquid line drier is Evaporator Defrost Control — See Low Ambient standard. Some models may require field installation. Cooling. A •id CERTIFIED,. wwwahridirectorynrg m ;4)us Unitary Small HP g�° AHRI Standard 210/240 annneab iru,T�niew zvaP u=�m,ninxai. Intertek Trane optimizes the performance of homes and buildings around the world.A business of Ingersoll Rand,the leader in creating and sustaining safe,comfortable and energy efficient environments,Trane offers a broad portfolio of advanced controls and HVAC systems,comprehensive building services,and parts. For more information,visit www.Trane.com. Trane has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. 02016 Trane 4TWR4024G-SUB-1A-EN 01 Mar 2016 � Ingersoll Rand Supersedesrsedes(New) COMcheck Software Version COMcheck-Web rft ill Mechanical Compliance Certificate Project Information Energy Code: 2018 IECC Project Title: Location: Tigard, Oregon Climate Zone: 4c Project Type: Alteration Construction Site: Owner/Agent: Designer/Contractor: 14830 SW 72nd Ave Tigard, Oregon 97224 Mechanical Systems List Quantity System Type&Description 1 HVAC System(Single Zone): Split System Heat Pump Heating Mode:Capacity=24 kBtu/h, Proposed Efficiency=8.50 HSPF,Required Efficiency=8.20 HSPF Cooling Mode:Capacity=24 kBtu/h, Proposed Efficiency=14.00 SEER,Required Efficiency: 14.00 SEER Fan System: FAN SYSTEM 1 —Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,800 CFM, 1.0 motor nameplate hp,0.0 fan efficiency grade 1 HVAC System(Single Zone): Heating:1 each-Central Furnace,Electric,Capacity=24 kBtu/h No minimum efficiency requirement applies Cooling:1 each-Split System,Capacity=24 kBtu/h,Air-Cooled Condenser,No Economizer,Economizer exception:None Proposed Efficiency=14.00 SEER,Required Efficiency: 13.00 SEER Fan System: FAN SYSTEM 1 --Compliance(Motor nameplate HP method):Passes Fans: FAN 1 Supply,Constant Volume,800 CFM, 1.0 motor nameplate hp,0.0 fan efficiency grade r Mechanical Compliance Statement Compliance Statement: The proposed mechanical alteration project represented in this document is consistent with the building plans, specifications, and other calculations submitted with this permit application.The proposed mechanical systems have been designed to meet the 2018 IECC requirements in COMcheck Version COMcheck-Web and to comply with any applicable mandatory requirements listed in the Inspection Checklist Name-Title S g t Date Project Title: Report date: 03/11/19 Data filename: Page 1 of 10 COMcheck Software Version COMcheck-Web II Inspection Checklist Energy Code: 2018 IECC (PA Requirements: 0.0% were addressed directly in the COMcheck software Text in the "Comments/Assumptions" column is provided by the user in the COMcheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Section # Plan Review Complies? Comments/Assumptions & Req.ID C103.2 Plans, specifications, and/or Complies [PR2]1 calculations provide all information ❑Does Not AAD with which compliance can be determined for the mechanical DNot Observable systems and equipment and ONot Applicable document where exceptions to the standard are claimed. Load calculations per acceptable engineering standards and ;handbooks. Additional Comments/Assumptions: 1 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 2 of 10 Section Footing/Foundation Inspection Complies? Comments/Assumptions & Req.ID C403.12.2 Snow/ice melting system and freeze omplies /l protection systems have sensors and fl-Does Not lit C403.12.33controls configured to limit service for ENot Observable [FO9] pavement temperature and outdoor temperature.future connection to ❑Not Applicable controls. Additional Comments/Assumptions: H. High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 3 of 10 Section # Plumbing Rough-In Inspection Complies? Comments/Assumptions & Req.ID C404.5, Heated water supply piping conforms I❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ENot Observable [ lot Applicable C404.5, Heated water supply piping conforms ❑Complies C404.5.1, to pipe length and volume ❑Does Not C404.5.2 requirements. Refer to section details. [PL6]3 ENot Observable T.__t Applicable C404.6.3 Pumps that circulate water between a ❑Complies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ENot Observable cycle. of Applicable C404.6.3 Pumps that circulate water between a EComplies [PL7]3 heater and storage tank have controls ❑Does Not that limit operation from startup to <= 5 minutes after end of heating ❑Not Observable cycle. SNot Applicable C404.7 Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or ❑Not Observable appliance and limits the temperature ot Applicable of the water entering the cold-water piping to 104°F. C404.7 Demand recirculation water systems ❑Complies [PL8]3 have controls that start the pump ❑Does Not upon receiving a signal from the action of a user of a fixture or ENot Observable appliance and limits the temperature fAlot Applicable of the water entering the cold-water piping to 104°F. Additional Comments/Assumptions: ill High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 4 of 10 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C402.2.6 Thermally ineffective panel surfaces of'KComplies [ME41]3 sensible heating panels have ❑❑Does Not insulation >= R-3.5. � ❑Not Observable inIk ❑Not Applicable C403.11.3HVAC piping insulation insulated inComplies [ME61]2 accordance with Table C403.11.3. Does Not Insulation exposed to weather is M r� protected from damage and is ['Not Observable ! ` provided with shielding from solar ❑Not Applicable radiation. .v. C403.11.3 HVAC piping insulation insulated in Complies [ME61]2 accordance with Table C403.11.3. EDoes Not Insulation exposed to weather is protected from damage and is ['Not Observable provided with shielding from solar ❑Not Applicable radiation. C403.8.4 Motors for fans that are not less than '.Complies [ME142]2 1/12 hp and less than 1 hp are ❑Does Not /(1V0 electronically commutated motors or have a minimum motor efficiency of ❑Not Observable 70 percent.These motors have the ❑Not Applicable means to adjust motor speed. C403.8.4 '.Motors for fans that are not less than # omplies [ME142]2 1/12 hp and less than 1 hp are '[❑]Does Not electronically commutated motors or have a minimum motor efficiency of ENot Observable 70 percent.These motors have the ` Jot Applicable means to adjust motor speed. C403.8.5 Each DX cooling system > 65 kBtu ❑Complies [ME143]2 and chiller water/evaporative cooling ❑Does Not system with fans > 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with )'dot Applicable detailed requirements of this section. C403.8.5 Each DX cooling system > 65 kBtu ❑Complies [ME143]2 and chiller water/evaporative cooling ❑Does Not system with fans > 1/4 hp are designed to vary the indoor fan airflow ❑Not Observable as a function of load and comply with Not Applicable detailed requirements of this section. C403.12.1'Systems that heat outside the building'❑Complies [ME71]2 envelope are radiant heat systems ❑Does Not controlled by an occupancy sensing ❑Not Observable device or timer switch. lot Applicable C403.2.3 HVAC equipment efficiency verified. Eomplies See the Mechanical Systems list for values. [ME55]2 ❑Does Not ❑Not Observable ❑Not Applicable C403.2.2 Natural or mechanical ventilation is omplies [ME59]1 provided in accordance with ❑❑Does Not International Mechanical Code Chapter 4. Mechanical ventilation has ❑Not Observable capability to reduce outdoor air supply ❑Not Applicable to minimum per IMC Chapter 4. C403.7.1 :Demand control ventilation provided ;❑Complies [ME59]1 for spaces >500 ft2 and >25 ❑Does Not people/1000 ft2 occupant density and served by systems with air side ['Not Observable economizer, auto modulating outside [Jot Applicable air damper control, or design airflow >3,000 cfm. 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 5 of 10 Section # Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.7.2 Enclosed parking garage ventilation ❑Complies [ME115]3 has automatic contaminant detection ❑Does Not and capacity to stage or modulate fans to 50%or less of design capacity. Not Observable pot Applicable C403.7.6 HVAC systems serving guestrooms in ❑Complies [ME141]3 Group R-1 buildings with > 50 ❑Does Not guestrooms: Each guestroom is provided with controls that Not Observable' automatically manage temperaturelot Applicable setpoint and ventilation (see sections C403.7.6.1 and C403.7.6.2). C403.7.4 Exhaust air energy recovery on ❑Complies [ME57]1 systems meeting Table C403.7.4(1) ❑Does Not and C403.7.4(2). ❑Not Observable VrOot Applicable C403.7.5 Kitchen exhaust systems comply with !❑Complies [ME116]3 replacement air and conditioned ❑Does Not supply air limitations, and satisfy hood ❑Not Observable. rating requirements and maximum exhaust rate criteria. Not Applicable C403.11.1 HVAC ducts and plenums insulated inomplies accordance with C403.11.1 and ❑Does Not C403.11,2 constructed in accordance with [ME60]2 C403.11.2, verification may need to ['Not Observable occur during Foundation Inspection. ❑Not Applicable C403.4.3. Closed-circuit cooling tower within ❑Complies 3.2 heat pump loop have either automatic ❑Does Not [ME121]3 bypass valve or lower leakage positive closure dampers. Open-circuit tower Not Observable within heat pump loop have automatic r. ot Applicable valve to bypass all heat pump water flow around the tower. Open-or closed-circuit cooling towers used in conjunction with a separate heat exchanger have heat loss by shutting down the circulation pump on the cooling tower loop. Open-or closed circuit cooling towers have a separate heat exchanger to isolate the cooling tower from the heat pump loop, and heat loss is controlled by shutting down the circulation pump on the cooling tower loop. _ C403.4.1. Heating for vestibules and air curtains ❑Complies 4 with integral heating include ❑Does Not [ME63]2 automatic controls that shut off the heating system when outdoor air ❑Not Observable temperatures > 45F.Vestibule Slot Applicable heating and cooling systems / controlled by a thermostat in the vestibule with heating setpoint<= 60F and cooling setpoint>= 80F. C403.3.3 Hot gas bypass limited to: <=240 ❑Complies [ME35]1 kBtu/h-50% >240 kBtu/h-25% ❑Does Not ❑Not Observable ot Applicable C408.2.2. Air outlets and zone terminal devices omplies ft 1 1 have means for air balancing. Does Not [ME53]3 ❑Not Observable ❑Not Applicable 1 High Impact(Tier 1) 1 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 6 of 10 Section Mechanical Rough-In Inspection Complies? Comments/Assumptions & Req.ID C403.5, Refrigerated display cases,walk-in ❑Complies C403.5.1, coolers or walk-in freezers served by ❑Does Not C403.5.2 remote compressors and remote [ME123)3 condensers not located in a ONot Observable condensing unit, have fan-powered �Rot Applicable condensers that comply with Sections C403.5.1 and refrigeration compressor systems that comply with C403.5.2.. Additional Comments/Assumptions: 1 High Impact(Tier 1) t Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 7 of 10 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C303.3, Furnished O&M manuals for HVAC Complies aM C408.2.5. systems within 90 days of system Does Not 3 acceptance. [F18]3 ❑Not Observable: ❑Not Applicable C403.2.2 HVAC systems and equipment ' I omplies [FI27]3 capacity does not exceed calculated LJDoes Not itiL , loads. 'ENot Observable E Not Applicable C403.2.4. Heating and cooling to each zone isomplies 1 controlled by a thermostat control. !❑Does Not [FI47]3 Minimum one humidity control device ENot Observable per installed humidification/dehumidification ENot Applicable system. C403.2.4. `;Heating and cooling to each zone is ❑Complies 1 controlled by a thermostat control. ❑Does Not [FI47]3 Minimum one humidity control device per installed ❑Not Observable humidification/dehumidification " Not Applicable system. 11 C403.2.4. Heat pump controls preventomplies 1.1 supplemental electric resistance heat EDoes Not [F142]3 from coming on when not needed. ENot Observable E Not Applicable C403.4.1. Thermostatic controls have a 5 °Fomplies 2 deadband. JDoes Not [F138]3 ENot Observable E Not Applicable C403.2.4. Temperature controls have setpoint Complies 1.3 overlap restrictions. ❑Does Not [FI20]3 ['Not Observable ❑Not Applicable C403.2.4. Each zone equipped with setback Complies 2 controls using automatic time clock or ❑Does Not b [F139]3 programmable control system. ENot Observable ENot Applicable C403.2.4. Automatic Controls: Setback to 55°F Complies 2.1, (heat)and 85°F (cool); 7-day clock, 2- ❑Does Not f'.l> C403.2.4. hour occupant override, 10-hour 2.2 backup ENot Observable [FI40]3 ENot Applicable C403.2.4. Systems include optimum startomplies 2.3 controls. ❑Does Not [FI41]3 ENot Observable ❑Not Applicable C403.2.4. Systems include optimum start 'omplies 2.3 controls. LJDoes Not [F141]3 ENot Observable ENot Applicable C408.2.1 Commissioning plan developed by EComplies [FI28]1 registered design professional or ❑Does Not approved agency. ❑Jot Observable of Applicable rIJHigh Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 8 of 10 Section # Final Inspection Complies? Comments/Assumptions & Req.ID C408.2.3. HVAC equipment has been tested to 1,51.2omplies 1 ensure proper operation. ❑Does Not [FI31]1 ❑Not Observable ❑Not Applicable C408.2.3. HVAC control systems have been omplies 2 tested to ensure proper operation, [[]]__Does Not [FI10]1 ,calibration and adjustment of controls. ❑Not Observable ❑Not Applicable C408.2.4 !Preliminary commissioning report 'FComplies [FI29]1 completed and certified by registered (❑Does Not design professional or approved agency. ❑Not Observable ❑Not Applicable C408.2.5. Furnished HVAC as-built drawings ':I omplies 1 submitted within 90 days of system ❑Does Not [FI7]3 acceptance. ❑Not Observable j❑Not Applicable j C408.2.5. An air and/or hydronic system ;❑Complies 3 balancing report is provided for HVAC ❑Does Not [FI43]1 systems. ❑Not Observable ,prtlot Applicable C408.2.5. :Final commissioning report due to ❑Complies 4 I building owner within 90 days of ❑Does Not [F130]1 receipt of certificate of occupancy. ❑Not Observable Not Applicable Additional Comments/Assumptions: I 1 High Impact(Tier 1) 2 Medium Impact(Tier 2) 3 Low Impact(Tier 3) Project Title: Report date: 03/11/19 Data filename: Page 9 of 10 ru:./ CERTIFIED° www.ahridirectory.org Certificate of Product Ratings AHRI Certified Reference Number:8908427 Date:03-11-2019 Model Status:Active AHRI Type:HRCU-A-CB Series:XR14 Outdoor Unit Brand Name:TRANE Outdoor Unit Model Number (Condenser or Single Package):4TWR4024G1 Indoor Unit Model Number(Evaporator and/or Air Handler):TEM4AOB24S21+TDR The manufacturer of this TRANE product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of ANSI/AHRI 210/240 with Addenda 1 and 2,Performance Rating of Unitary Air-Conditioning&Air-Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored,independent,third party testing: Cooling Capacity(A2)-Single or High Stage(95F),btuh:23800 SEER: 14.00 EER(A2)-Single or High Stage(95F): 11.50 Heating Capacity(H12)-Single or High Stage(47F):22400 HSPF(Region IV):8.50 t"Active"Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale;OR new models that are being marketed but are not yet being produced"Production Stopped"Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is still selling or offering for sale. Ratings that are accompanied by WAS indicate an involuntary re-rate. The new published rating is shown along with the previous(i.e.WAS)rating. DISCLAIMER AHRI does not endorse the product(s)listed on this Certificate and makes no representations,warranties or guarantees as to,and assumes no responsibility for, the product(s)listed on this Certificate.AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s),or the unauthorized alteration of data listed on this Certificate.Certified ratings are valid only for models and configurations listed in the directory at www.ahridirectory.org. TERMSAND CONDITIONS ALUM' This Certificate and its contents are proprietary products of AHRI.This Certificate shall only be used for individual,personal and confidential reference purposes.The contents of this Certificate may not,in whole or in part,be reproduced;copied;disseminated; • entered into a computer database;or otherwise utilized,in any form or manner or by any means,except for the user's individual, personal and confidential reference. AIR-CONDITIONING,HEATING, CERTIFICATE VERIFICATION &REFRIGERATION INSTITUTE The information for the model cited on this certificate can be verified at www.ahridirectory.org,click on"Verify Certificate"link we make life better'" and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above,and the Certificate No.,which is listed at bottom right. ©2019Air-Conditioning, Heating,and Refrigeration Institute CERTIFICATE NO.: 131968097827332994