Plans (3) $ - - $ EWP Studio Client: Lennar Date: 1/23/2019 Page 1 of 3 Project: Designer: Peter Rezac 40 40, SiMIMI:3n StrOng-Tie® Address: Touchstone Townhomes Bldg 3 Job Name: 190049 -7V P Component SOILItiOnsTM Units 12-16 Project#: J4 RFPI 90 16.000" - PASSED Level:Main Floor OFFICE COPY mil 2 " il V 1 .. ato= IHIHIHWilHrF REfl'eq ,.."' 'I ' ' iliitii!Hil 1 [EB 7 2013 ., ,„ -- - - '''i CITY1,2;FifAr,s,i D 14 1 / . 3 .1L ) 01rli01 " - (8] / 1 Hanger 2 Hanger(IUS3.56/16(Min)) / / /---/ 86 1/83 1/2"" / / 86 1/8" Member Information Reactions UNPATTERNED lb(Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wind Const Spacing: 21"o.c. Design Method: ASD 1 301 113 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 295 111 0 0 0 Deflection LL: 480 Load Sharing: No Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-I- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General LoadBearings Vibration Span: 26-5-6(31%) Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF 1 - 3.000" 25% 113/301 414 L D+L Hanger Analysis Results 2- 2.000" 28% 111/295 406 L D+L Analysis Actual Location Allowed Capacity Comb. Case Hanger Moment 817 ft-lb 43 9/16" 13865 ft-lb 0.059(6%) D+L L Shear 397 lb 2 1/8 2330 lb 0.170(17%) D+L L LL Defl inch 0.012(U8578) 43 5/8" 0.206(L/480) 0.060(6%) L L TL Defl inch 0.016(L/6239) 43 5/8" 0.412(L/240) 0.040(4%) D+L L LL Bare Defl 0.012(L/8084) 43 5/8" 0.275(L/360) 0.040(4%) L 40 PSF L Design Notes 1 Fill all hanger nailing holes. 2 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Part.Uniform 0-0-0 to 8-6-2 0-10-8 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Tie-In 0-0-0 to 8-6-2 (Span)1-9-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF to 1-9-0 MST2019-00041—8933 SW ELENA LN MST2019-00048—8895 SW ELENA LN MST2019-00042—8929 SW ELENA LN MST2019-00049—8891 SW ELENA LN MST2019-00043—8925 SW ELENA LN MST2019-00050—8887 SW ELENA LN MST2019-00045—8921 SW ELENA LN MST2019-00051—8883 SW ELENA LN MST2019-00046—8917 SW ELENA LN MST2019-00052—8879 SW ELENA LN u 1 •-•1 14 —:8" ELEN° LN > < to 000,, Manufacturer Info Notes chemicals 5 Provide lateral support at bearing points A':ril a'-iii7,-,ZAfra,,,oR lateral disMacement and rotahon Calculated Structured Designs is responsible only of the Handling&InstallationRoseburg Forest Products USA 6.Web stiffeners for point load as shown Minimum structural adequacy of this component based on the 1 Moist flanges must not be cut or drilled point load bearing length>. incines 4500 Riddle By-pass Rd 97071 responsibility ytendef theenddudtlooamdernrgasddishorothwnd.coldtizorththe 2..Refer to latest copy of the IJoist product information 7.For pending roofs provide proper inches to prevent Riddle, OR 97469 503-981-4424 details for framing details,stiffener tables,Web hole ensure the component suitability of the intended chat,bridging details,multi-ply fastening details and (541)784-4005 application.and to venfy the dimensions and loads. hadingrerectron details www.roseburg.com Lumber 3.Damaged!Joists must not be used APA:PR-L259,ICC-ES:ESR-1251 4.Design assumes tap flange to be laterianilyenrgesntreazdead d sons,unless noted otherwise by attached sheathing or as specified 31:nestenNoitcteochentreated oath fire retardant or corrosive notes. This design is valid until 7/10/2021 ECM EWP Studio Version 18.32.163 Powered by iStructiim =MI - 7.7— cs EWP Studio Client: Lennar Date: 1/23/2019 Page 2 of 3 41 k,40, Simpson Strong-Tie® Project: Designer: Peter EWP Component SolutionsTM Address: Touchstone Townhomes Bldg 3 Job Name: 190049 Units 12-16 Project#: J5 RFPI 90 16.000" - PASSED Level:Main Floor 2 1 ''':;";'''''':: :7,''t`:''':,—..;:x; .. ,...,. O / 1 Hanger 2 SPF / 10'9 1/2" / /--/3 1/2" / 10'9 1/2" / Member Information Reactions UNPATTERNED lb(Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wind Const Spacing: 24"o.c. Design Method: ASD 1 428 161 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 435 163 0 0 0 Deflection LL: 480 Load Sharing: No Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-l- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General Load Vibration Span: 25-5-9(41%) Bearings Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF 1- 3.000" 35% 161/428 589 L D+L Hanger Analysis Results 2-SPF 4.000" 32% 163/435 598 L D+L Analysis Actual Location Allowed Capacity Comb. Case Moment 1474 ft-lb 5'4 1/4" 13865 ft-lb 0.106(11%) D+L L Shear 569 lb 10'6 3/8" 2330 lb 0.244(24%) D+L L LL Defl inch 0.026(L/4872) 64 1/4" 0.259(L/480) 0.100(10%) L L TL Defl inch 0.035(L/3543) 54 1/4" 0.518(L/240) 0.070(7%) D+L L LL Bare Defl 0.028(L/4486) 5'4 1/4" 0.345(L/360) 0.080(8%) L 40 PSF L Design Notes 1 Fill all hanger nailing holes. 2 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Part.Uniform 0-0-0 to 10-9-8 1-0-0 15pSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Part.Uniform 0-0-0 to 10-9-8 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF Notes °hemi°ala 5.Provide lateral support at hearing punts to avoid Manufacturer Info Capital Lumber Calculated Structured Designs is responsible only of the Handling&Installation lateralsdifenens for and rotation 2980 National Way,OR 6.web ed bene for point load as shown Minimum 4500 Riddleg By-pass ass Rd USA structure)adequacy of this component based on the 1.IJoist flanges mustnot becut or&lied point loadbeannglength>=3.Sinches 4500 By-pass Rd 97071 rdesponsibiliiteri fthe eustomergand/or the cantrecmrtito 2.Refer to latest copy of the IJoist product information 7.For flat roofs provide proper drainage to prevent Riddle,OR 97469 503-981-4424 e the component suitability of the intended charts for framing details,stiffener tables,web hole ponding 784-4005 application,and to veri the dimensiene and loads. chart,bridging details,multi-pty fastening details and (541) N handling/erection details www.roseburg.com Lumber 3.DamagedlJoissmustnetbeused APA:PR-L259,ICC-ES:ESR-1251A -,11 t.Dry service conditions,unless noted otherwise 4.Design assumes tap flange to be laterally restrained 2.IJoist notto he treated with fire retardant or corrosive by asached sheathing or as specified in engineering TAL This design is valid until 7/10/2021 EWP Studio Version 18.32.163 Powered by iStructnu I lit EWP Studio Client: Lennar Date: 1/23/2019 Page 3 of 3 Project: Designer: Peter Rezac ,,„, SiMp5On ent StrOnSOlUtiOnSTm Address: Touchstone Townhomes Bldg 3 Job Name: 190049 CoMpOn Units 12-16 Project#: J6 RFPI 90 16.000" - PASSED Level:Main Floor . . ililiThi 1111M11111: 2 iiiiltiljiljiiiikiiiiHill01.111111HWThill!!!jilH/iiii.fli!:111j! !!1- ------- ----------L------------------------- - ------- 1 ----- --------- ------- ---------- --------- -- - ,,,,.% ,,-.d, -,-- .:= , -------4 ,... I _ , ,,T,"2...; .„-,-,--*,:- I , -.,„,,v .7,,7., ----14 -"! . . . ., I / 14" / 1 Hanger 2 SP, 3 Hanger / 910 1/2" 0 44" / / / /—/ 910 1/2" 44" 3 1/2" / / 142 1/2" Member Information Reactions UNPATTERNED lb(Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wind Const Spacing: 24"o.c. Design Method: ASD 1 361 135 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 691 259 0 0 0 Deflection LL: 480 Load Sharing: No 3 85 32 0 0 0 Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-l- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General Load Bearings Vibration Span: 28-2-4(34%) Floor Live: 40 PSF Vibration Span: 28-2-4(15%) Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF Blocking: 910 1/2" 1 - 3.000" 30% 134/361 496 L_ D+L ' Hanger Analysis Results 2-SPF 5.500" 27% 263/700 963 LL D+L Analysis Actual Location Allowed Capacity Comb. Case 3- 3.000" 12% 29/173 202(-51) _L D+L Neg Moment -584 ft-lb 910 1/2" 13865 ft-lb 0.042(4%) D+L LL Hanger Unbraced -553 ft-lb 910 1/2" 12396 ft-lb 0.045(4%) D+L L_ Pos Moment 1031 ft-lb 46 1/16" 13865 ft-lb 0.074(7%) D+L L_ Shear 594 lb 910 1/2" 2330 lb 0.255(25%) D+L LL LL Defl inch 0.019(L/6262) 411 3/16" 0.242(L/480) 0.080(8%) L L_ TL Defl inch 0.025(L/4566) 411 1/8" 0.485(L/240) 0.050(5%) D+L L_ LL Bare Defl 0.020(L/5910) 411" 0.323(L/360) 0.060(6%) L 40 PSF L Design Notes 1 Fill all hanger nailing holes. 2 Tie-down connection required at bearing 3 for uplift 51 lb(Combination D+L,Load Case L_). 3 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Part.Uniform 0-0-0 to 14-2-8 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Part.Uniform 0-0-0 to 14-2-8 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF Manufacturer Info I Capital Lumber Notes 5.Provide lateral support at bearing points to avoid Id 2980 National VVay,OR lateraisplacement and rotation Calculated Structured Designs is responsible only of the Handling&Installation 6.Web stiffeners for point load as shown Minimum Roseburg Forest Products I USA structural adequacy of this component based on the 1.hoist flanges must not be cut or drilled point load bearing lengthb=3.5 inches 4500 Riddle By-pass Rd I 97071 design criteria and loadings shown. It . the 2,Refer to latest copy of the!Joist product information 7.For flat roofs provide proper drainage to prevent responsibility of the customer and/or the contactor to details for framing details,stiffener tables,web hole bonding Riddle,OR 97469 503-981-4424 ensure the component suitability of the intended chart,bridging details,multi-ply fastening details and (541)784-4005 application,and to verify the dimensions and loads. handling/erection details WWW.roseburg.com Lumber 3.Damaged!Joists must not be used APA:PR-L259,ICC-ES:ESR-1251 AIIPITAL .Desgn assumes top flange to be laterally restrained 2.Deist not to be treated with fire retardant or corrosive notes. This design is valid until 7/10/2021 EWP Studio Version 18.32.163 Powered by iStruct. ...gmi. It EWP StudioClient: Lennar Date: 1/23/2019 Page 1 of 3 Simpson Strong-Tie® Project: Designer: Peter Rezac Address: Touchstone Townhomes Bldg3 Job Name: 190049 Component SolutionsTM Units 12-16 Project#: J5 RFPI 90 16.000" - PASSED Level:Upper Level Idl,it)iji 11=',iiia flfiH1 iIt W 2 1 / ri - 1.4.. z / 1 Hanger 2 Hanger(IUS3.56/16(Min)) / 10'9 1/4" /--/3 1/2" / 10'9 1/4" Member Information Reactions UNPATTERNED lb(Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wind Const Spacing: 24"o.c. Design Method: ASD 1 434 163 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 428 160 0 0 0 Deflection LL: 480 Load Sharing: No Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-l- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General Load Vibration Span: 25-5-9(41%) Bearings Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF 1- 3.000" 36% 163/434 597 L D+L Hanger Analysis Results 2- 2.000" 40% 160/428 588 L D+L Analysis Actual Location Allowed Capacity Comb. Case Hanger Moment 1516 ft-lb 5'5 1/8" 13865 ft-lb 0.109(11%) D+L L Shear 578 lb 2 1/8" 2330 lb 0.248(25%) D+L L LL Defl inch 0.027(L/4735) 5'5 1/8" 0.262(L/480) 0.100(10%) L L TL Defl inch 0.037(L/3444) 5'5 1/8" 0.525(U240) 0.070(7%) D+L L LL Bare Defl 0.029(L/4356) 55 1/8" 0.350(L/360) 0.080(8%) L 40 PSF L Design Notes 1 Fill all hanger nailing holes. 2 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Part.Uniform 0-0-0 to 10-9-4 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Part.Uniform 0-0-0 to 10-9-4 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF Notes chemicals 5.Provide lateral support at bearing points to avoid Manufacturer Info Capital Lumber lateral displacement and rotation 2980 National Way,OR Roseburg Forest Products USA Calculated Structured Designs is responsible only of the Handling&Installation s Web stiffeners for point load as shown Minimum structural adequacy of this component based on Me 1,Moist flanges must not be cut or drilled point load bearing length>=3.5 inches 4500 Riddle By-pass Rd 97071 design criteria and loadings shown. It is the 2,Refer to latest copy of the(Joist product information 7.For flat roofs provide proper drainage to prevent Riddle,OR 97469 503-981-4424 responsibility of the customer and/or the contractor to details for framing details,stiffener tables,web hole ponding ensure the component suitability of the intended chart,bridging details,multiply fastening details and (541)784-4005 application,and to verify the dimensions and loads. handling/erection details www.roseburg.com Lumber 3.Damaged[Joists must not be used APA:PR-L259,ICC-ES:ESR-1251 I 1.Dry service conditions,unless noted otherwise 4.Design assumes tap flange to be laterally restrained AP/`SAL 2.!Joist not to be treated vats fire retardant or corrosive by attached sheathing or as specified in engineering notes. This design is valid until 7/10/2021 EWP Studio Version 18.32.163 Powered by iStruct° si.i r EWP Studio Client: Lennar Date: 1/23/2019 Page 2 of 3 1 ;> Simpson Strong-Tie® Project: Designer: Peter Rezac [WP Component SolutionsTM Address: Touchstone Townhomes Bldg 3 Job Name: 190049 Units 12-16 Project#: J6 RFPI 90 16.000" - PASSED Level:Upper Level — 2 1 y ., I itil .:, ,-,. , N - 01.4., 1 Hanger 2 Hanger / // x/31/2" / / 14'2 1/2" Member Information Reactions UNPATTERNED lb(Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wind Const Spacing: 24"o.c. Design Method: ASD 1 568 213 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 568 213 0 0 0 Deflection LL: 480 Load Sharing: No Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-l- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General Load Bearings Vibration Span: 25-5-9(54%) Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF 1- 3.000" 47% 213/568 781 L D+L Hanger Analysis Results 2- 3.000" 47% 213/568 781 L D+L Analysis Actual Location Allowed Capacity Comb. Case Hanger Moment 2639 ft-lb 7'1 1/4" 13865 ft-lb 0.190(19%) D+L L Shear 762 lb 2 1/8" 2330 lb 0.327(33%) D+L L LL Defl inch 0.064(L/2588) 71 5/16" 0.346(L/480) 0.190(19%)L L TL Defl inch 0.088(L/1882) 71 5/16" 0.693(L/240) 0.130(13%)D+L L LL Bare Defl 0.071(L/2333) 71 5/16" 0.462(L/360) 0.150(15%) L 40 PSF L Design Notes 1 Fill all hanger nailing holes. 2 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 4 —Part.Uniform — 0-0-0 to 14-2-8 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Part.Uniform 0-0-0 to 14-2-8 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF chemicals 5.Provide lateral support et bearing points to void Manufacturer Info Capital Lumber Notes lateral displacement and rotation 2980 National Way,OR Calculated Structured Designs is responsible only of the Handling&Installation 6.Web stiffeners for point load as shown Minimum Roseburg Forest Products USA structural adequacy of tins component based on the 1.IJoistflanges must not be cut or drilled point load bearing length>=3.5 inches 4500 Riddle By-pass Rd 97071 design criteria and loadings shown. It is the 2.Refer to latest copy of the!Joist product information 7.For flat roofs provide proper drainage to prevent Riddle,OR 97469 503-981-4424 responsibility of the customer and/or the contractor to details for framing tletails,stiffener tables,weh hole ponding (541)784-4005 e the component suitability of the intentled chart,bridging details,multiply fastening tletails and application,and to verify the dimensions and loads. handling/erection details www.roseburg.com Lumber 3.Damaged IJcists must not be used APA:PR-L259,ICC-ES:ESR-1251 API ram. t.Dry service conditions,unless noted otherwise 4.Design assumes top flange to be laterally restrained 2.!Joist not to be treated with fire retardant ar corrosive no attached sheathing or as specified in engineering tes. This design is valid until 7/10/2021 EWP Studio Version 18.32.163 Powered by iStructoo Client: Lennar Date: 1/23/2019 Page 3 of 3 EWP Studio , ,,, Simpson Strong-T.ie 0 Project: Designer: Peter Rezac Component SOIUOnSTM Address: Touchstone Townhomes Bldg 3 Units 12-16 Job Name: 190049 Project#: J7 RFPI 90 16.000" - PASSED Level:Upper Level 01001 lillir 0101100I ' ..-- 2 3 --<- --' --- 4__ 000000000001100 000I0 --- 1 I: 3 / 1'4" A ' t233 / i I i 1 1 SPF 2 SPF / / 773/4" / / 77 3/4" Member Information Reactions UNPATTERNED lb (Uplift) Type: Joist Application: Floor Brg Live Dead Snow Wnd Const Spacing: 24"o.c. Design Method: ASD 1 217 82 0 0 0 Moisture Condition: Dry Building Code: IBC/IRC 2015 2 217 82 0 0 0 Deflection LL: 480 Load Sharing: No Deflection TL: 240 Deck: 1-1/8 APA Rated Sturd-l- Importance: Normal FloorOSB Nailed and Glued Temperature: Temp<=100°F Vibration: OK General LoadBearings Vibration Span: 25-5-9(27%) Floor Live: 40 PSF Bearing Length Cap. React D/L lb Total Ld.Case Ld.Comb. Dead: 15 PSF 1-SPF 5.688" 16% 82/217 299 L D+L 2-SPF 5.688" 16% 82/217 299 L D+L Analysis Results Analysis Actual Location Allowed Capacity Comb. Case Moment 473 ft-lb 39 7/8" 13865 ft-lb 0.034(3%) D+L L Shear 274 lb 4 13/16" 2330 lb 0.117(12%) D+L L LL Defl inch 0.006 39 15/16'. 0.171(L/480) 0.030(3%) L L (L/14148) TL Defl inch 0.008 39 15/16" 0.342(L/240) 0.020(2%) D+L L (L/10289) LL Bare Defl 0.008(L/9858) 39 15/16" 0.228(L/360) 0.040(4%) L 40 PSF L Design Notes 1 Bottom flange braced at bearings. ID Load Type Location Trib Width Dead 0.9 Live 1 Snow 1.15 Wind 1.6 Const. 1.25 Comments 1 Part.Uniform 0-0-0 to 7-7-12 1-0-0 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 2 Tie-In 0-0-0 to 0-10-3 (Span)0-1-1 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF to 0-11-4 3 Part.Uniform 0-10-3 to 6-9-9 0-5-10 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF 4 Tie-In 6-9-9 to 7-7-12 (Span)0-11-4 15 PSF 40 PSF 0 PSF 0 PSF 0 PSF to 0-1-1 Capital Lumber Notes chemicals 5.Provide lateral support at bearing points to avoid Manufacturer Info 2980 National Way,OR Calculated Structured Designs is responsible only of the Handling&Installation e Wreltnter:rr gidntritoeras shown Minimum Roseburg Forest Products I USA structural adequacy of this component based on the 1.!Joist flanges must not be cut or drilled point load bearing length>.3.5 inches 4500 Riddle By-pass Rd 97071 design criteria and loadings shown. It is the responsibility of the customer and/or the contractor to 2.Refer to latest copy of the!Joist product information 7.For flat roofs provide proper drainage to prevent Riddle,OR 97469 503-981-4424 details for framing details,stiffener tables,web hole ponding ensure Sre component suitability of the intended chart.bridging details,multiply fastening details end (541)784-4005 applicaton.and to verify the dimensions and loads. handling/erection details www.roseburg.com Lumber 3.Damaged!Joists roust not be used APA:PR-L259,ICC-ES:ESR-1251 AIPIITAL 4.Design assumes top flange to he laterally restrained 1.Dry service conditions,unless noted otherwise by attached sheathing or as specified in engineering 2.IJoist not to be treated Mth fire retardant or corrosive notes. This design is valid until 7/10/2021 EWP Studio Version 18.31163 Powered by iStrucfm 1=1 MEP