PFI2019-00070 111111 CITY OF TIGARD PUBLIC FACILITIES IMPROVEMENT PERMIT COMMUNITY DEVELOPMENT Permit#: PFI2019-00070 13125 SW Hall Blvd.,Tigard OR 97223 503.718.2421 Date Issued: 03/06/2019 TIGARD g Parcel: SEG2086 Jurisdiction: Tigard Site address: Subdivision: Lot: Project: PGE Job M2495679 Project Description: SEG2086, 2087, 2110, 2111, 2133, 2134, 2135.Work associated with 9580 SW Lakeside Drive. 12 segments of underground primary. See attached site plan. PGE Job M2495679 Owner: FEES Description Date Amount PFI Permit Fee 03/05/2019 $752.50 PHONE: Contractor: PHONE: FAX: Applicant: PHIL MERRIMAN 10800 SW AVERY STREET TUALATIN, OR 97062 PHONE: 503-612-2918 Total $752.50 Please sign below to indicate acceptance of conditions and return a copy with the proposed work schedule along with names and contact information of responsible parties before beginning work. Permittee/Applicant Signature: -?t-- a_ pu ,-, Issued By: Aff1/1A2 Z Special Conditions(See Attached) Note:THIS PERMIT DOES NOT COVER WORK ON PRIVATE PROPERTY Conditions for PFI2019-00070 Type: Condition Name: Status: Severity: PFI_Utilities 01 -WORK SITE REQUIREMENTS Applied Notice Applicant must comply with all applicable provisions of federal and state law, the Tigard Municipal Code, and the terms of any agreement with the City of Tigard regarding work to be done pursuant to this permit. PFI_Utilities 02-WORK SITE AREA Applied Notice The work area and approach roads shall be maintained in a clean condition, free from obstructions and hazards. The spreading of mud or debris or storage of materials or equipment of any kind upon any public roadway is strictly prohibited and violation shall be cause for immediate cancellation of the permit. The City may at any time order immediate clean-up and suspension of work to accomplish clean-up. PFI_Utilities 03-WORK SITE EROSION CONTROL Applied Notice Prior to starting work, effective and approved erosion control devices must be installed and maintained meeting the Clean Water Services and DEQ requirements. The City may at any time order corrective action and suspension of work to accomplish effective erosion control. PFI_Utilities 04-WORK SITE REPAIRS Applied Notice Disturbed landscaped areas shall be restored or replaced. Existing signs, pavement markings, mailboxes, etc. shall be reinstalled or replaced, with like kind of material. Obtain City approval of restoration work. PFI_Utilities 05-TRAFFIC CONTROL SPECIFICATIONS Applied Notice Applicant shall provide traffic control according to the current edition of the"Manual on Uniform Traffic Control Devices [MUTCD]for Streets and Highways", U.S. Dept. of Transportation, FHWA, current edition, American Traffic Safety Services Association[ATSSA], and Oregon Temporary Traffic Control Handbook[OTTCH]. PFI_Utilities 06-TRAFFIC CONTROL PLAN Applied Notice Submit a job specific traffic control plan. A copy of the approved traffic control plan shall be readily available at the work area. Traffic control devices, flag persons, etc., shall be in place prior to initiation of construction work and shall be effectively maintained. PFI_Utilities 07-TRAFFIC CONTROL ROAD CLOSURE Applied Notice Public roadway shall not be closed to traffic, at any time, without obtaining written approval from the City Engineer. The applicant is responsible to provide 48 hour advance notice of traffic flow disruptions to affected businesses, residents and area wide Emergency Services: 503-629-0111 (Tigard Police Dept., Tualatin Fire&Rescue)and to 503-962-8140(Tri-Met) and 503-431-2345(Tigard School District)and other service providers impacted by such closure. PFI_Utilities 08-TRAFFIC CONTROL ADVANCE WARNING Applied Notice Advance warning of traffic disruption shall be provided to the public by placement of an approved advance notification sign at each end of the construction area 72 hours(min.)before initiation of construction work. PFI_Utilities 09-TRAFFIC CONTROL PROPERTY ACCESS Applied Notice Access to existing properties shall be maintained at all times, including normal delivery service and mail service. Obtain City approval of any access closures. PFI_Utilities 10-TRAFFIC CONTROL WORK HOURS Applied Notice Work is permitted in daylight between the hours of 7:00 a.m.to 7:00 p.m. Mon-Fri unless otherwise authorized by the City. PFI_Utilities 11 -TRAFFIC CONTROL LIMITED WORK HOURS Applied Notice Hours of construction work on collector and arterial roads will be limited to 9:00 a.m.to 3:00 p.m. unless authorized by the City Engineer. Work will not be permitted on collector and arterial roads between 3:00 p.m.to 9:00 a.m. unless authorized by the City Engineer. PFI_Utilities 12-TRAFFIC CONTROL MODIFICATION Applied Notice The City reserves the right to add to or modify traffic control requirements as necessary to effectively control traffic and to assure public safety. PFI_Utilities 13-DRAINAGE CONTROL Applied Notice Drainage shall be controlled within the work site and shall not adversely affect adjacent private property, public property and the receiving system. The City may at any time order corrective action and suspension of work to accomplish effective drainage control. PFI_Utilities 14-UTILITY NOTIFICATION Applied Notice Oregon law requires following the rules adopted by the Oregon Utility Notification Center. Said rules are set forth in OAR 952-001-0100 through OAR 952-001-0080. Copies of said rules may be obtained from the Center by calling 503-246-1987. If you have any question about the rules, contact the Center. NOTE: Damage to utilities shall be corrected at the permit holder's expense. PFI_Utilities 15-UTILITY LOCATION CONFLICT Applied Notice Applicant must verify all existing utilities for both vertical elevation and horizontal location prior to start of work(pothole before digging if necessary). Should conflicts arise and redesign or relocation of facilities be necessary, it shall be done at the applicant's expense. Changes must be approved by the City in advance of work.Applicant shall coordinate the work with affected utility agencies. PFI_Utilities 16-TEMPORARY PATCH Applied Notice A temporary hard-surface patch shall be placed on trenches within roadways at the end of each work shift. Obtain advance approval of patching method. No trench shall be left at any time in an un-safe condition. Applicant is responsible for and is liable for hazards or damage resulting from the prosecution of the work. PFI_Utilities 17-REPAIR OF EXISTING FACILITIES Applied Notice Work under this permit shall include repair of existing facilities(roads, ditches, etc.)as may be necessary, as determined by the Inspector, to overcome deterioration or damage which occurred in conjunction with the work authorized by the permit. Corrective work shall be done at the applicant's expense. PFI_Utilities 19-PRECONSTRUCTION MEETING Applied Notice Before initiating any construction activity, the applicant shall coordinate with the City's inspector, <Insert Name>at<Insert Phone#>, to establish a preconstruction meeting. PFI_Utilities 20-NOTICE TO COMMENCE WORK Applied Notice The applicant shall notify the City's Inspector twenty-four(24) hours prior to commencing work, prior to any staged inspection, and after completing work covered by the permit. PFI_Utilities 21 -PERMIT/PLAN ON SITE Applied Notice A copy of the permit including a Certificate of Insurance, and all attachments, and a copy of the approved construction plan and all amendments shall be readily available at the work area. All work shall conform to the permit terms, conditions and provisions and to the City approved permit plans, and approved plan amendments and to the City's standards and specifications and to these General Conditions. Changes to any of these must be approved by the City, in advance of work performance. PFI_Utilities 22-DAILY INSPECTION REPORTS Applied Notice Applicant shall submit daily inspection reports, on a weekly basis, to the City's Inspector. PFI_Utilities 23-MONUMENT PROTECTION Applied Notice Existing monuments, property corners, and survey markers shall be protected. Replacement shall be at the permit holder's expense. PFI_Utilities 24-VALIDATION OF MATERIAL/CONSTRUCTION Applied Notice The City's Inspector may, at his discretion, require tests and or reports from the applicant to validate claims of material or construction adequacy/compliance. Such tests/reports shall be provided at the applicant's expense. PFI_Utilities 25-EMERGENCY CONTACTS Applied Notice Provide to the City inspector, in writing,the names and 24 hour emergency telephone number of two(2)persons who have authority to resolve problems,take corrective action and, in general, will be responsible in case of any emergency. The applicant shall notify the City Inspector, in writing, of any/all assignment changes. PFI_Utilities 26-RIGHT OF ENTRY/EASEMENTS Applied Notice Applicant to obtain proper right-of-entry and/or easements prior to starting work. Proof of right-of-entry or properly executed easements, shall be provided to the City. The City shall in no way be construed to be liable for the applicant's failure to obtain or provide for proof of right-of-entry or easements. PFI_Utilities 27-PRIVATE PROPERTY AGREEMENTS Applied Notice Provide the City a copy of an executed agreement[s]from the owner for each private property disturbed by construction activity. PFI_Utilities 28-AS-BUILT DRAWING Applied Notice 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). 1,2,3,4,5 28-AS-BUILT DRAWING One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). One as-built drawing showing all new public improvements, including any revision made to the previously approved construction plans and, also, any improvement which may impact an existing public system or facility, shall be provided to the City by a registered civil engineer along with an engineer's certification of installation compliance(Certificate of Compliance). PFI_Utilities 31 -OTHER Applied Notice Other RECEIVED a PUBLIC 11111 I City of TigWORKSard— ENGINEERING FEB 2 7 2019 CITY OF TIGARD Public FacilityIm rovement (PFI) P1ThtENGINEERING TIGARD +e TYPE OF WORK DESCRIPTION OF WORK(in the right-of-way) V TYPE 1-Ijranchise Utility Work Check one: VUtilities ❑Sidewalk/driveway approach ❑ Streetimprovements performed by NWN, PGE Detailed description: 12 SEGMENTS OF UNDER GROUND PRIM AR Y and/or utility agency. 13CW-4,&air G9`e-9 i- ❑ TYPE 2—Sidewalk/Driveway/Sewer PGE Job M2495679 Work performed for the purpose of: • Sidewalk installation or repair. • Driveway approach installation Property address/location(s): 9580 S W LAKESIDE DR. and/or repair jt 2135Z 110 f i j Tigard, OR 97224 • Sanitary sewer lateral installation 1 ' LA16 14,E 2,13.-I L..1 i 1 and/or main line tap PGENance Stone V El TYPE 3—Full scale Development (Submitted Applicant: by ) Work performed with Land use Address: 10800 SW Avery Street approval which includes any of City/state: Tualatin, OR Zip: 97062 the following: Phone: 503-612-2918 Email: preregcoord@pgn.com • Subdivisions or Partitions Contact name: Phil Merriman Phone: 971-804-3579 • Street widening • Mainline installation for Sanitary Contractor Potelco, Inc. sewer, Storm sewer, Tigard water and/or"Tigard Water Service Area CCB#: 76668 Expiration: Address: 3884 Pacific Hwy SUBMIT COMPLETED APPLICATION TO: City/state: Hubbard, OR Zip: 97032 City of Tigard Planning/Engineering Phone: 503-902-0244 Email: jrlarsen@potelco.net 13125 SW Hall Blvd. Contact name: Jason Larsen Phone: 971-275-6954 Tigard,OR 97223 ,5.'G3 93 -'9,4 g Applications for"minor work in right-of-way" Engineer: only may be emailed to: rowpermits(a'�,tigard-or.gov Address: I OR S 111 I l SI O\I.l City/state: Zip: Phone: Email: Case No.: P H H 2.0 0 H O 0 40 Contact name: Application submittal fee(.007%of Engineer's Estimate) $ Estimated value of work is required(if over$5,000):$ Additional fees: $ 7 2 0439 (within the public right-of-way) Application accepted: Is work related to a LAND-USE DECISION? El Yes I/No By: - Date: 12714-1 41 If so,please specify (MLP,SDR, SUB, etc.) case #: Applicatio wed: By: Date: Is work related to a BUILDING PERMIT? ❑ Yes tiNo Applicant notified: If so,please specify(BUILDING PERMIT)case#: By: 3�� Date: - -1 t I:\ENG\PermitApplications\pfi_application Rev.10/16/2017 City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page I of APPLICANTS NOTE: Person specified as"Applicant"shall be designated"Permittee"and shall provide financial assurance for work,if required by the city pursuant to TMC 15.041.140. * With the exception of a utility operating pursuant to a valid franchise with the City of Tigard,when the owner and the applicant are different people,the applicant must be the purchaser of record or a lessee in possession with written authorization from the owner or an agent of the owner. The owner(s)must sign this application in the space provided or submit a written authorization with this application. Franchised Utilities are not required to obtain the owner's signature on the application BY SIGNING BELOW,THE APPLICANT(S) SHALL CERTIFY THAT: • The above request does not violate any recorded deed restrictions that may be attached to or imposed upon the subject property. • If the application is granted,the applicant will exercise the rights granted in accordance with the terms and subject to all the conditions and limitations of the approval. • All of the above statements and the statements in any plot plan,attachments,and exhibits transmitted herewith,are true;and the applicants so acknowledge that any permit issued,based on this application,may be revoked if it is found that any such statements arc false. • The applicant has read the entire contents of the application,including the policies and criteria,and understands the requirements for approving or denying the application. Vinh D Nguyen, Digitally signed by Vinh D Nguyen,PE PE Date:2019.02.2712:27:48-08'00' Vinh Nguyen Applicant/Authorized Agent's signature Print name Date SIGNATURES of each owner of the subject property,if required. Owner's signature Print name Date Owner's signature Print name Date Owner's signature Print name Date PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • www.tigard-or.gov • 503-718-2421 • Page 2 of DEVELOPMENT ENGINEERING FEES FOR STAFF USE ONi_\ Public Facility Improvement(PFI)Permit: DETAILED SUBMITTAL APPLICATION FEE REQUIREMENTS Part 1: Required submittal fee$300.00(minimum) FRANCHISE UTILITY AND SIDEWALK/ DRIVEWAY AND UTILITY PERMIT FEE CONNECTIONS,ETC. Part 2: All non-water system improvements (work in the right of way) Engineer's estimate X 5%(less$300.00 minimum submittal fee) Sketch Engineer's estimate X 2%Plan Review (including information below) ❑ Dimensions WATER SYSTEM FEE ❑ Street Name Part 3: All public water system improvements ❑ Site Address Engineer's estimate X 12% FULL SCALE DEVELOPMENT PFI Permit Fee Exemptions: (Subdivisions/Partitions and Street Improvements) There will be no permit fee charged,or assurance required for the following types of work: Design Plans • Sidewalk repair(less than 20 lineal feet) (6 sets,24x36 or 22x34) • Relocate or replace mailbox ❑ Cover—Site,Vicinity,Abbreviation,Legend • Ditch cleaning that does not involve regrading. ❑ General Notes(City,Water,Sewer,etc.) • Weep hole repair ❑ Street(Plan,Profile) • Curb repair or replacement(less than 20 lineal feet) 0 Water,Storm and Sanitary(Plan Profile) • Lawn sprinkler system installation or repair ❑ Water Quality Facilities • Street tree pruning or planting ❑ Grading • Planter strip landscape maintenance Cl Landscaping/Tree Plan • Test wells ❑ Composite Utility Plan(Electrical,Phone,Gas, Storm,Sanitary,Water,Signage,Street Lights,etc) ❑ Details Note: A cash/bond assurance may be CI Traffic Sight Distance required per TMC 15.04.140. ❑ Signing and Striping (customer deposit) ❑ Street Light Plan and Photometric ❑ Engineers seal/signature ❑ Sheet label(project land use name,revision and plan log block,dates and sheet numbers.) Additional Submittals (per Land Use conditions) ❑ Traffic Report ❑ Storm water Drainage Calculations ❑ Geotechnical Report ❑ Preliminary Access Report(Sight Distance) ❑ Proposed Plat ❑ Pathway Design(if applicable) ❑ Water Department Approval ❑ Engineer's Construction Estimate PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 3 of4 SAMPLE SKETCH: fc) Iv •• x _ .1. I Edge of P avement --"i°42/61 Ditch _•,... 0 Streetlight I --i ty ,,, , .i.—.—.—.—•!•—r—.: Ram Dram `I ."'.'` r ® r _ _4 -....- .,...-a" ti 1 ,fes. �� �"1 I Ir • T— Pr'o'os�ct"S'eali NA ei flnnee I P I .: Existing House -til I Existing r • Driveway I 0 ,,,,,cit i4)ri gl IT-1 O1 asII I • e U5�iF j I El c/a01 01r I I I' °r I Existing Shop Powerpole 1 I .- 1 a I r� 1111\ fir,,,- • I I 1 --------157operiyLine----------- r I 1 0 . Fire Hydrant(FH) I I I ■ I I Scale: I'=30' 1 • 1' I I I I. 1 I MINIMUM SKETCH REQUIREMENTS(Put"N/A"if Not Applicable): North arrow Property lines &dimension Slope of property Street &street name(s) Existing building, structures Utility& street light poles Proposed work Existing curb or edge Trees Existing S/W or of pavement Existing utility locations D/W apron (sewer,water,storm) PUBLIC FACILITY IMPROVEMENT PERMIT City ofTigard • 13125 SW Hall Blvd. • Tigard,Oregon 97223 • wwwtigard-or.gov • 503-718-2421 • Page 4 of LEGEND � ,,. 28 W� 2117 P0-I5451 EXISTING OPENVA12 PU-15516 A+w - IF, - EAsnNc OPEN POTION IAT 1..,� WLte VT-301 10#2 EPR in 2"HDPE CONDUIT WWII '.�;•�4�, BOTIOu v.Ull •"',;S / �K�je�j WALT .roki viuLi �swt Q '! sA �;. ,'-S �f 1 20#2 EPR in 4"HDPE CONDUIT 0 �I tikt \� ` t pm ..� ~ \�/• tT ... � ' 1 { ,°•y 1Wthairi15T NAMTAM s FT.NOR12WTAL SEPARAIpx FRg1 O . F; •�' �!�)�� + _•• RATER YAMS AND 1 FT.VERTICAL SEPARATION BELOW. j, ■lam 2.1lSF 45'/90'B[NDS fOR CKN BO110A1 vAIILR._! ,1.. = �l!molio X s� ! It.' FGD CUT BLVD ABM MARC TO PROVIDE SLATS, %6�.'' ` ` WW. ~'r s.REiOpl:ac�p•"tROIRoI R°�DDs K"assn i'coRRDsa°I DISCO..DARING CON51110.. J NST.l S 5[ we TD masy. TO P9'.-41552,1 5 CHECK COOROMATDN OF SME,L.,RS. ag00" NIII IE NMI W.I TI --4 ,-15.57 FAS'LE`.EL OF RANYORwCR�TO PD-'55' A GOAD ABAIDd4D CARE RR LC77Q11N). WLS VI-1096) WLB PU-15511 MLI}VI-15306 NL19 PD-1551/ NL15 PD-162/9 FASTING VAULT �— CASTING OPENi. EASING VAULT [ASTINt OKM » [%STING OPEN `16 , BOITON VAULT gIOL VAVII +�._ .�,y 1: BOTlp4 VAULT AIL••• II�I ', 11(0 ' r, El:_....,.7' 10 vT-M) .0,,,;::::; IV —410 Vi-Tt) 10 PD-15316E-i `_ATO vi-301 10 PL-131.1 V R1-9 V7-387 WL14 VI-15305 WL1U PO-15516 y�p� �°p CASTING CP[N up .U�` 4s7 5 LACI / CO vY / X50 B°TTOw vAulT ;- 0741-011 imicat. Fes_ y! rYV f I '-',.,/,p 1111k.„-IT/0X ". 4111010 _ - °°"\ �`.<o l3Jto I .i.°4". � :,e vAUT1 5 P0-I551)E-, IllWILIF IS A+ - Y.110.-,5b20 fS ` .05 V1-15304 WL21 91-A43 K or /�.e ANVPN 9. --,•,•• ...ti, <>4411'0idrileit \ ro5 . . ... ` ..1011414.0 1 'U._N . 4 r a' ,; ' - I ` r EAs1rD vAuti .‹,5` ,r. WL6 1,-15452 WL11 PO-15519 WL17 PD-+5523 %21 PD-15524 PST.OPEN CASnNG •OPEN EASnxG OPE, CASTMGVOMx • 01TOU VAULT .... sOTll ULT BOTTOw VWLT _ �'� BOnDN ULI ....... i --- '', - A iam�• ''.. 1,11----___ 1. _W _..... .4,„,_,, , .. 10 PD-15516E-+ ...,1,.,_)„. .,,,..,,,..... ,,...... I->T0 V1-36' v-2' TO vT-.43E-I I-,TO VD-16915 NNW INA X rr.R. lir L.,. JC FIS M per.."' .41 TRITON CALL SI I BEFOGS POO DIG OAlE00NU W FEMMESYOU M FOLLOW RUES ADOPTED811. THINK wTT.RUES SE1..'Mtn+ulroNm0,0 TK.ISE RUES MCSEFVW M O AFICMdES 010 SAFErI' 41RAiN4MONdpO rauAwvnet calFsal FIRST' .7:=4:=7"7::=7........-Rg7.V'Ar2V-Z112.GALL2NFO,7''' K.....,[e6r6W urAm V°TFrunt±N,,,,,, ,,,,,,,N%2 CN Wen you Hs PGE CONSTRUCTION DRANIJC' SOPAHENO REVIEW I AS-BIAL TBYDESIGNER: AS-BUILT VERIFICATION 6 NESS VIOLATIONS CORRECTED mr:e°�N.e„I ettrm%AA..P•.:.M,creta�nrP�. OF: DIM: °•.'F'12/0//2016 ui11F MS 1......”10)0001 IA`q'1066007 1111 +/2^.::332242_ Ma \ UNJAUNJACKETED CARE REPLACEMENT-FARMMCTTON SOLGN J-T.070FT CC [M1BEl14fANY r 2.40 CKETEDWINNER ST,KSI&OR,92002 wwwww 72 SEOYENTS OF IRIDE:OROUD PRILG9L. ry A4C v4N pooKAT9w WASHINGTONWASHINGTONC1119L,CMM C1119B.C11190 Nr .a3 IeA:aMTER CAl.wer 221.3 SW MP.* PHIL MERMAN 971404-3A141HEIDI SOOT.: ![1DFkTPN.6R NrM GP°RRRxO aEAERA'ELECTRIGM-ALL NKAN23 r.sERVEo Page 84 2011 Edition N Stationary Lane Closure with Flagging Diagram 320 Diagram 320 covers total closure of one lane of a two-lane, two-way N roadway. See the detail inset for the layout if using a single flagger to control both directions of traffic on low volume roads (less than 400 ADT)with good sight distance as discussed below. 1. Use truck-mounted flashing warning lights on work and protection vehicles. See Section 4.3— Lights and Lighted Signs for exceptions. 2. For added visibility, a truck-mounted arrow board or PCMS in caution mode may be used. 3. Flaggers at each approach are required if any of the following conditions exist: a. Night Operations. b. Work space is over 200 feet in length. c. Sight distance is less than 750 feet from each approach through the lane closure. d. Traffic volumes are greater than 400 ADT. 4. The length between the Flagger Ahead signs shall not exceed one mile. Use Diagram 340— Lane Closure with Pilot Car if exceeding one mile. 5. Cones should be used to outline the work space when curves or other roadway alignments prevent clear direction for the motorists to pass the work space safely. 6. Cones along the work space are recommended when posted speeds are 45 mph or greater, when working under heavy traffic or when travel lanes are narrower than 11 feet. 7. Extended queue signing (see Diagram 5-4) should be used when traffic queues extend beyond the initial advance warning sign. 8. When flagging near an intersection, the "Flagger Ahead" (CW23-2) sign should be visible to traffic entering from any side road. Additional advance warning and Flagger Ahead symbol signs may be placed on the side road(s). 9. Sign set-up and flagger placement shown may be used for intermittent full road closures of 20 minutes or less. 10. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues are expected. Chapter 5 December 2011 2011 Edition Page 85 N v Stationary Lane Closure with Flagging Diagram 320CD CN X'c 2 C cr / o ES 3 W a`) o o� o 0 0hi C.: l Tas a 4--------- wa 0 m a� m LL 0Eic_1 a 4.1 • 7) o,t I. A • O E. al 0 i, 1 A .2.+8'6 A1 1 m • +-Qa�i mom - E 1, § aM� ` I TE• IIII� 3 c • ii 0 ..-, loi • a • I • CD m30 •cT \ / LL If' i 8 o �' wa ow I m'� wi t 1r V CO CSign Spacing and Buffer Lengths(feet) V \ w a Posted Spacing Between Signs Buffer U p 2 0 FL Speed A B C Space V zz cc Q O 20 50 ' 25 100 100 100 75 \ ' 30 100 35 125 0 Y 40 350 350 350 150 O O 45 _ 180 IX 50 500 500 500 210 55 250 December 2011 Chapter 5 Page 118 2011 Edition Lane Closure at Intersection with Flagging Diagram 620 Diagram 620 covers work within an intersection when normal traffic control must be interrupted. Work vehicles may or may not be in the work space. 1. During flagging, traffic signals shall be turned off. Contact the road jurisdiction for approval and assistance (see Chapter 3). 2. For multi-lane facilities, traffic approaching the intersection shall be reduced to a single lane on each approach. See Chapter 3 for information on flagging through intersections. 3. There should be one flagger for each approach. One flagger may control two adjacent approaches if sight distance, low volumes on side roads, and flagger position allows for safe operation and clear direction to motorists. For low traffic volume intersections (fewer than 400 entering vehicles per day), one flagger may be used. 4. The "ONE LANE ROAD AHEAD" (W20-4) sign is optional and should be considered on high volume or high speed roads, or when extended queues may be expected. Sign Spacing and Buffer Lengths(feet) Posted Spacing Between Signs Buffer Speed A B C Space 20 50 25 100 100 100 75 30 100 35 125 40 350 350 350 — 150 45 _ — 180 50 500 500 500 210 55 250 Chapter 5 December 2011 2011 Edition Page 119 Lane Closure at Intersection with Flagging Diagram 620 ROAD WORK A AHEAD ONE C + 1 1 (Optional) ROAD E W AHEAD B BE PREPARED - TO STOP W B• -• W A (Optional) ELANE ROAD 100 ft Max. • PREPE.,� AHEAD ROAD • TO STOP WORK • AHEAD ABBCI ► Buffer • \ • ® CD ...0 �. irl. _. E5 K .: K K 1 !-------------1004_Max. C B B A I ROADBE • T WORK PREPARED • AHEAD TO STOP • 100 R Max. . LANE ROAD . AHEAD • (°Pda"al A V BE V PREPARED TO STOP B pow,* V ONE LANE I 1 HE D C AHEAD ROAD V WORK AHEAD December 2011 Chapter 5 1—LINE DIAGRAM 0 ,5•4«71,,: NA,xk. .,,,x ,„ A...,..n�° ,0.;i " a52 «,� -1".0=7,3, A ► ► �` .:: C2 1-11B C7 1-ifA C21.12 eon Al AMA n,, ..__ i L. nx :►n.,» 11 444,5• :l x,nR, . .ru. _, '. ran •r, w" i11 1 SS '1-1 46 I g '. ig DA. ulL ,r.'3' ,w-. m.•4 rm: Pk.up 4•11,1110. Is, l ii..rn - -- _ en, „ ' vr,. I`yn., Iv?''' ; •.,..,,, p___`,.. ,t.,,„;;;,.•,- riZt.,,, . •num,«-n, .irtitl, Oil.»»ev, „4aa R" ,r ,,,., r,,«, •r,«„ e» ," i q" 1r1� o Ax ,x, .�,`I- : x,., ►.....�.. ,,,, ; .'n., NEL ASIC �1 nnV u 0.-5,,, •»,im A w".N, 0.. ANL.mAAr. N.A. j,n,a" .nn t„:„Ne�'t pt.vi , NwAK ;ORIAREA Op ”. i�' y,.. emer a .,, c ` ' c», l ” uew» A r,,,,r,-11"''r,-11"'''''- . n.. _i I--4' -Scar :"., LT. aen» —n.r- i a„e »ren, ,o!MI r. n ,. -_ n VT-.1•0 n '.° ,,,,,r4:.... , , 1 2C • 1012 ""7.,'.,», »,,. » :,, ea„ :::::: • ANY DEVIATION FROM THIS DESIGN MUST ,a,- A nts,„.'»� "' n '0 ��" �,• - ix u n, RE APPROVED BY THE PGF PROJECT MANAGE, n can » . n FAIT;Il lFF01E YOU 0l' '�,, E c� • as /HIN\ 8'' ,», 715•4 SAFETY Z,`7°`"M`:',,.l",T''' 8p FIRST a.a:w,,,.,.,_ Rrn rout urRrrr 7ce7rsrulr7o.T.. +... c» Noi UM USINESSUTpMDAYS IONTOECAArlfa UDR YI"•,en� - r: N/noN SHEET MYf 11.70 BIATID^ IS•gUIIT VcPFlOI/ION 1 NESL'WNW.Alx,n, »fe,il ,» N., T ;E/SSW LAKESIDE DR.iK3MD.OR v. N , G ATH'IN x wnY .wm .SEGMENTSa UNDERGROUND PRIMARY SfcTrdvS w.. �ING ONI C:,t,C CIt,tO I .OF. , er wrnrIt»,wx e. /..".. "1:1',04 ••••...'.r gn,rL n»oMN SWIM LELEPINEN .1.741;:a. A. _ _ _ — / �� 1 PGE N In LEGEND n 4u .+woes 'S%5 p79 A 50 WI 29 r AMMO. 464 _T P4Rr 11�WM,�y SW DARNEL CT 1505'!`r 1992 ., ,. SCR!4095 51]197!4 r p0 ttB 1202, POLES 23,202.0. S-- POLE CUSS(1,2.J.0.111.M.SI �+ .>py5 roo, :16 MOVE 57 B 25 14379"1 - - POLE HEIGHT A 1541 275,✓T $ +5, ra..l SW TLUE LM SO- . PDd` 0' � CONDUCTORS JL1:1 a I R x,.0wa4e1r P Z e,3, „-T9raWr SW LADY 4' ••1 15,05 �' ro-35- r4J3�L _—_-- AMMONOR' C]06JJ76 ; .t- 9595nT.e4rmd•.O CAetr PEW lcUw., 5 u� + 02589111 rl a 0012• 4i.3 , , 3 �'' m gel ,x EQUIPMENT 99912 tr9 � 20M r IV,MN< .o r.tc r.nw4:4i w T-'4 ,999 w ouroMN runs R.4 W� R ` MCMr, 15 41034 x11.:2511 C2552T65 vA.r� + 3 ' • INSTALL MULL rNkr i a+ «o.Ac c 1511 ue A•C MAAC IP 1565576 WI,M.wR.wn illo 3W SATTLER Si u0AAC 15110 w, •," •7 254 To 15-N .,r 91015• . .+, ..\ aP• . ..,.,..Y . �J3 °A3 1512, 7' :y V. v y v,.,. .1 ~ 4061 20 r.. '?two a 1745_. 15x99::m4,Aar M-xmT.,n4-e3K _V +s:.9 ws,w,.. "'" .05 MOW eI.Jkmc4aE-/WK P�.0<GO 710 IVY. 1]215 ess. L IADSCAPWG NOTES M v�A 25 57520 •n d '� iR>7 w.t' w[, 'Side 132. ,5.., am WIZ PD-kT9n M1, 0 13271 Sy • POST LANDSCAPE-GRASS SEED !1 0 MI 3 PE•GR 3 15x[, B 10 SOS mm •u: 1w, 95� 152r 15x09 PRE UWSCAPE-255.1 BACK DM. PO4 — 00 210M ,s„s 1 POST LANDSCAPE ZBARk OUST 'C 50 28034 vT-� 1 [ N . .W •,.. • PRE LANDSCAPE:-TRN BACK SHRUB RR��(AT{�� mA Q 45255 :-:'-:::›11—1%4 POST LANAPE-BARK DUST A 254 51x Y 'roan• SoeS 10221,w,[ � 190' . rt1oN w,-xrorM,-rant �,.. • .. ,,,,�a���\VVV�••-lJJJJ Dl 410.4310I.<m ua[-c.� 1 152,0 e PD): m slorlrm-xro52. ,. C7608N a POST LAN NI 7110-BMKDUET + seau C2/4/C 4 uzM;; POST LANDSCAPE.B11Rk DV6T m Tuwwr.xroc.aE.wAt V V. - M rya4nWtn-xrouaA-Na MIA P0.7e,3 °'•. rr 4555 021 .... 15200 POST LANDSCAPE-BARN DUST �J y - -5137 W 26M MOW TJA1.-NAL 152,5„§ .7 rTi •Yi '.5285 r PE•ARK DU. 'wLero-r. - a. • w5,r 20.,4,1. POST LANDSCAPE REQUEST VEGETATE �� pe[s ISNR•w Nr.Ann Qom.. 1 ww. TO CUSTOMER RE0UE6T ,5290 )NS 9909 me•W art-xro Twa,:waL 4GMB ;,,.SL_____ ©CQ010N1 15215 mu•NrM-Jkm baiw M3 y2111PD-T ICAPE-TOP MSI • .ni 110 r7 „t i ,� n14 M0 M 4__--_ ••,• /// •3293 POST LANDSCAPE-TOP SOI rr ''SP' w B DR • -C2rLL. M.12 Pa7e15 1 %. Ii46 ll%1 0101.• L1 tetl PRE LANDSCAPE•REMOVE SHRUB ak•ro, >M -0 Q0802112 1:21 Ir.. SNN� a,n30 1200 jDJ71 ---- wNal9W w,.,Kmcnaa-w c sa 28085 -• • 1918 l%9 ._ wA`' n Y Cm SRI 1505 /y3 000 28349 Ny��- �[ 1'501�,R .' MAI Kzo %N• r 4;n3� t9k5 2920 I 1126 �, 1,-21 y� Ren 9473 9•o n- WV 94Y 9150 943D BUR' mon 0 ,. IN9 .,neu.m.Jkro Twat-en4 ww 9%a gun �� 9235 Neo '''(1.'"45 r-v�,3 .z.L,w•,w,.xro nwaa-NK 1114 t�tt+y `)N' ,.�sA• reg C•/ f0•} IW c00 21399 ` __---- - 6 N% 1K 2MM. uvr.m wWwusowwnANw<Rn•5.. ©• u N NOTES w • ,9 12.. 9121 r�wraW BAOwM-10(20 Wtr-4vN r,•reliWeR•AIroTJN4 Wl �, w !rel • I.MUST MAINTAIN 5 FT.HORIZONTAL SEPARATION FROM ,sem MIS 000,..•1 - .riu....... 1___ WA 151WM .... 1.6212.5.3,-242544.1.... WATER MAINS AND I FT.VERTICAL SEPARATION BELOW. [3,0 m, 0 Mn ., MxWL9nh TAAD ow clrLlwrtEwnS 2.MAINTAIN 1 FT.SEPARATION FROM CRY OF TIGARD Nen ALI mtwWrm-x42 Wueau 49239 CATCH BASKS. Y^xrs r,z sm. •'Nl �m4u9Wm-xro W...aw >r ]-USE 451I 921'BENDS,FOR OPEN BOTTOM VAULTS. ..Tut Or w.mr.74.20.13.121.22220 FIELD CUT BEND ABOVE GRADE TO PROVIDE SUCK 5 FOR SWITCHING.(PULL TENSIONS ASSUME 80-BEND). r..5 4.REPLACE GROUND RODS INF EXCESSIVE CORROSION �Rww.SKu-w•c.IrwwSQwww ,An IS DISCOVERED DURG CONSTRICTION. OPe.Nw 13104.444214 2221:07.3214,24,002 t r`•Qy lsux Y S.GROUND ABANDONED CABLE PER LC22035-I 7112109 IVAM Hn.132.2241•021•240 ,u5 I„= nor I.CHECK COORDINATION OF STREET LIGHT FUSING Ilt ,o4 W B50 71200 ,SM, . ts.R ANY DEVIATION FROM THIS DESIGN MUST C22-1TD SE APPROVED BY THE PGE PROECT MANAGER SW � DR 15w3 5 C 50 33716 830 7N0 1545, vT 555 2,W 421 SEMI!,YOU D.,Sw, /11111N/\(\ N9 vr �.+ 15457 SAFETY MOSE RUM .FOAwm 2401.10` 811� aa<.r,,mr99wm.,0...,9.ka. >+ 15,,..9, ,NIST b K "rb ::, '.,59 1,0.0,4 SSS +.,. n+ / rDAEOu4s,urrl:77,ArrSurlrNrnar...,r.•a.... w,e UTrun Nornfrerinw trw,IP,1111.1111 Call rlaeti4k 2 eusrNlss n9r+r•,r�v r�r aT.S-..r,. ARE cm.NMC11ON Mumma 15.9: Asan.,yr v B ea 18118 R1M5 FI_ r. E24emmt Ale • ..n Genpl kw.. pr,e 155010785 SCPWENG REVIEW VSBLJLT81 IFSMNER F�e� -V141111- 5,4 � .9x05 V,-7 v,-ne , + 05018364 T24T20121 In.705 I6L1'070001 r100000T634 I k12U.. S9' ro• , 2534 N111711. e Sita VILE \ UNJACKETED GABLE REPUCEeENI.DUIUN NORTH I-J.e05Fi �� � ,an / pURHAAF6ATTLER 1331[11 �1•ai zp K r9,$1Y SUMNERFTE 9'a 4 t - 9590 x530 sem yv �s• A ;E/,:e0 SW LAKESIDE DR RGARD,D s N m'SA 4Il• pj 125Ed%ENTS OF UNDERGROUND PRIMARi e If won 0 40 AO 160 `^'6° - 55 ••n ,. .+,n re.•r. ....e.,a..•,.cS.V.Br TON!02,11 C.C2111D I 1Gi3 ,5509 x3b.e. a.wwn r • 1 1 ...........„,.........------1610 350.. s ww PHIL LERIWAN 571.881.357)KYLE LEMPNEN r N HI,NO arorw,r,sCSW GO.Nl RCVS N3L5'er0 RECEIVED MAR 0 4 2019 .... . CITY OF Ti(jAiirlip 15020 15570 PLANNINR4ENeihre*KG -,..r.,'.. - . 4113 31114211 14357 99-4 SW DARNEL CT .57 ,,,,,, ,952 1.551 .115 15134 .":''''''' •ill 59 56•1111 ,/.9. PD.119 15114 POLES Pew 74,43404= 1---POLE CLASS(I.Z 3.4.141.HZ S) Izet 3434 IRV NORIUT 1O-CL 0,1 •24 1437ermi Vs!: ''' 1:.'": Ns. .. 15.5 .i. I--POLE HEIGHT 1002, 1555 g 1554i ANTI., 20,4 :01 I MPS WW2 19% , i PISZSI e .- CONDUCTORS in i WAS •5107 g 9047 I ‘ SW LADY f1. ss, _ C Br' "n1 15125 ,..„ 97, 3.1 i I 1•11%. C 2.11.4111 1...„ 05•4 ;24 4*-4 WE PD. E0UIPAIE7IT UM NAUNImm ,,, .„ 1949. 4114 41E4 Tir,tt'S f 16 41034 C MINN 4Iii?",'.' C MI ININV rx 135•••••4:• - II Wt VI IS% '4,4 g "Ni i••r, 51010 t..t,,,,,••set.y.L sLAo 15165 5559 51110.151,J1,0 CAM-PM ., .. c Non.mow tart 'n LANDSCAPING NOTES V 5240 95, •15. 9.2 ''...' 15_15 ...11"11 V 84 4 ' 51e1 irt 5.53 •457 132X 0 POST UNDSCAPE-GRASS SEED WI.3 PO-A797 PRE LANDSCAPE•TAN BACK SHRUB ‘,.. a , POST UWDSCAPE-MIRY.DUST N MN (.1. WI.•PO-2 11i, 1 j..,-_- C.2.5.5 V.g 1St, ,9'.: ' UO pr, NZILrem: . PRE LANDSCAPE-TANA BACK SHRUB ,elafr....--......, wa, +Mi. . . '<Ai ANAVOT,N100.08•104 9/47 15,55 POST UNDSCAPE-BARE DUST WL 6 P0-3. AN, I 011:-.93. 1„,..,.,,,„ . r.‘,....._.... 1110 a NA] :'1 I POST UNDSCAPE-SARK DUST WI 7 P11.78 , C NNW ..14.6....NoCamt6460. ... D2 546D .IT, 15265:1 POST LANDSCAPE-BARK DUST .1 WL 9M-791J ED F1110wor•...111CANF•FM .'.,' WIS .792 DS. 11124 4.4 es. MM Inv I -4.......:,..,..,........:1,..„,i..::i 1 ‘w., POST UNDSCAPE-BARK DUST 1,41, '5137 15265 WL 9 PD-7414 if ...:7-' •F 9571 ,„.,•,• POST UNOSC.PE-BARK DUST It VEGETATE TOLL/STU...ER REQUEST ,.4 • Pt F11049917,111CAMENAl 0 :, ONSUM9 AP•AND cANE.N. POST LANWLDS'CAPTf TOP SOL 4.2 . NM .55 9925 ,"PI" MILINNI NT 4WD CMLIEWL ID.1.110.9911-9110.1101-41. WL 11 PD-7815 9449 .1 WN MN .•• ‘,:„ ..-.-• -----------i.[AL- ;; '''' •E2,.. POST UNOSCAPE-TOP SOIL WI 12 PD-7015 i.: . ..., ,...I\ i .. .... ..--,...,_... RRE LANDSCAPE•REMOvE SHRUB MST UNDSCAPE•BARN DUST A VEGETATE . •.4, m....' 2414 110.7•14 sni. . 0 10 CUSIONER REOUL SI --Al RR, (Z) SNOWS,ST '-;$1.1.1911-NT0 W.94244 0 s ir k 5725 DV .7.• .•----;2,-- ... ,,,,,,, PI ZION ;.2. Pro r „ ... ... 1•3515 9970 ,,\ z W71 ...:, .' .. re ellown•4011 EANS-NAL , , 0::.„./--"‘ - a : 3.. .2. \ 7.,.....0,,,.• 1.MUST MANTAIN 5 FT.HORIZONTAL SEPARATION FROM „,,., wv, ....TELSOW KIT-NTS GME-SIN WATER IAAMS ANO 1 FT.VERTICAL SEPARATION BELOW. 1 sse4 •e 2 I,--,,,,,,--- .•a_: .. . MO 151115 '7r ,„, V c,,.....•19.„=.STANDOFF 2.MMNTAIN 1 FT SEPARARON FROM CITY OF MARC/ 7.`,,:.7" CATCH BASINS. 'XI' WV MDSOW NT•ALTDCAOLS,MAL M. 29-4 W17 4 r OteLNAS NT-ALTDDSOLS-NAL 111711 3.USE 45,110.BENDS.FOR OPEN BOTTOM VAULTS. FIELD CUT BEND ABOVE OFIADE TO PROVIDE$LACK MAMA.OFINVOL NEVINTO NE mem 1342.s v FOR SWITCNNG.(PULL TENSIONS ASS)11&KT BEND/. "...::r'' 4.FtEPLACE GROUND ROOS IF EXCESSIVE CORROSK. 154130 IS DLSCOVERED DURING CONSTRUCTION. ....trC 112 tit ISFAS ,,,.. I 5.GROUND ABANDONED CABLE PER LC22035-7. .4 tNowlr.Am=4.4. Pos 6.CHECK COORDINATION Of STREET UNIT FUSING. "7,4)...1.614 kiuMNIMMAN.A 17;;.1. 1900 ,•101, 15561 .....:.b..., 1 # ANY DIVIATION FROM TH5 DESIGN MUST 'W7 /55•10 Cl 5110 SE APPROVED BY THE POE PROJECT MANAGER RV IN1ONWID OA 'CO 3•7111 '""•SI''11111 1551 4, 114110 /pill./ 0 •,,, NVSE 0240.41.2 Ift FORTH.01114.0 05.2 002 OM SAFE,. 200220001222 1202.0.M0 KW kW 012.2 CONDO, .. •• TM 11/5,5 11V r4t11/45 Mr cmtraorr LRAM 154,6 15475 13:?;t: \\F,IRS/1, 22072220.20200 21421221 00.00022022000.(302-2.12•10212 70 020212 2 r 072022 200‘22 2.11 TUE 0012604.........1.1. •5597 0 15465 UM frr NOW,AVON 21022/2 II I AT 1.5/ 01111.100.201. 2 IUSINE55 02,2 MON',I 00,2010022 ..1. 11•LI•16101•02t0221.20.2.6061..'' ''' '-'....M. 11.1M 1.95 %T ,,,,,,,N .1.111111111611114111.MI.. ... ' WS 96, 9.5 v555 .45 15540 , WO iallWI ••11.11.111.1111.1161111.1 SI INN 1110/21111bMW.4;17001 NO0007634 PL.22.M. 6.......33-4..... .1.11132.-•iO......,..511.0.1.ia 402r.1.1 telTrE101111110121 1911 P..* 1171 -..':11' I 4.0 BYt LAKEN.DR 11GARD OR No. ., ..• 12 EEOMIENTE Of UNDERGROUND PRIMARY ..41:".i 1974 . 19711 19r4 714 91 TO MOD fa, N. ,,,, ISST4 ,...„,,, irligtdrinIMINEIM 110 111 94, .44.. FL0,1 15.0 leitTn11.121!!! 'l 1-LINE DIAGRAM JAN 1.14 Lagi /IT.00 IT 2. r Ii ; ". 4. ee. Nn . + ,F. 001. LJ i Ct 1.1113 ii c as A vw r' f • xuwimoc.e, -'a'x !�.'le's=II,44 , 1w» ;I'''. i''''''.. TA:UT00.41) »a • 1 I I 0 I AR ! waw, t1li " n w� uv a a. .. s WORK ale-rE oRaea x�,.' o a.r.e, » .r .,. ! 111 .». di Op Ow sill c OL>r,,,... W ,/...'. l''.""" ' '11.*11:44 _.-\\ir ._wr 1,.. ..r.:-.= .. (,:1.11 q ,-+N C2 1-11D rT.'-'i.a.,�, ..e_.. <ro.r ...pp:. ,., .n:,u ='�'JP6 "� .w, ros 6.16 ew/��,�,�c r... .ee.» JE r.s'a n'°.^ 'w IIrr:. - it. .:r... " _ ro+. „, ,r---- ww..�,'-n, _ C'” p'- ,°� ' • wr0"'+r Tey ` bea �r _ 1OJi ma, M. rcrr2ro. rm.III W RrM _ /THIN\ 811 ' ..... __-:_.___:- _t"_-.....� , SAFETY + ✓ A_ ",w, a '� .��; .__.._ \FIRS .7,,,,a..r.,..u.,.r,...o.,� »„—az sane. ea w..illl�'+11k a»a+RR„„ xe »r c.�E.l..lary R 25,5 N[ OR 10 a v -5C..""".” C 0 r=fr.'"IINL.,. .....\•,..../c..? NlfdVl/RGt1,dN 011A1..1. are. S BUILT VCRiFi. TIONS tORRCLTi.-i` dflIPt PUT SFS'• G:.:70: Orl.. A1r_w A�V, VERip7h�P'webYnaw,m,a.fw)N..,rt»-yY.� r / HS&.t.1 B{{Y��LwwFSRilg1.• A 4P �J—. / r� n_,. re, r11n.5011 �10f0001 x 100000TL11 E11.Qs5TR ,i'l '� UNACKETEU CABLE REPLACEMENT-W1.1.NORTH I JIEOS, t111111111 ) ,„...,. � x»r. en \ BIINNIA..-9ATTLER I x3.J, Ccna ram \ ;E/YstOswLAKEsoEoPcTgARp.OR i .nrev ti•I,re I NIB Di U.gERGRouNO MiMMv e 60 lie i.B Teel '"' ,»e+ AD ill � cror/�ixlirc,ez,ue „�1pR""� zoiz v,.0 N ren.PIQ MFARMAN p1.lM.YST9 ELFWYf_r. ti n n new.A BSx..'m�..�P.P.it-eeatc RECEIVE`;, MAR 0 4 2019 CITY OF TIGA LEGE NNING/ENGINEEI ----- 10#2 EPR in 2"HDPE CONDUIT PD-8796 PD-7816 • • I PD-28 I NpiFe. 1 PL-5213 1. MUST MAINTNN 5 FT.HORIZONTAL SEPARATION FROM WATER MAINS AND 1 FT.VERTICAL SEPARATION BELOW. 2- MAINTAIN 1 FT.SEPARATION FROM OTT CF RGARD INSTALLED ON M2495688 CATCH BASINS.IP-5— PD-2 IP 6 S. USE 45'/90 BENDS,FOR OPEN BOTTOM VAULTS FIELD CUT BEND ABOVE GRADE TO PROVIDE SUCK y DURHAM-NORTH K FOR SNITCHING.(PULL TENSIONS ASSUME 90'BEND). PD-3Asr IP-7 4. REPLACE GROUND RODS IF EXCESSIVE CORROSION IS IP-3 / 5. GROUND DISCOVERED DURING CONSTRUCTION. ABANDONED CABLES PER22035. 7. IP-4 Jyly 6. CHECK COORDINATION OF STREET UGHT FUSING. PD-8797 IP-1 ► PD-7814 PD-7815 VT-81—' 0 PD-7813 VT-191 J IP-2 PD-2 INSTALLED ON M2495688 DURHAM-NORTH K o.+.l WL2 HU-8196 c+.., WL6 PD-3 WL10 PD-2 m•r. I • EXISTING OPEN EXISTING OPEN EXISTING OPEN _ TRENCH—FOOT TABLE TRANSFORMER LOADING �— BOTTOM �� BOTTOM vs 4.:"4isno..r. VAULT )g.w'R VAULT .ITOM '..u.—au(n� PIMfE S� t0/ RIM NEWT PN 01411117 AUL r sa Ire ��=,„, T C !Y II63{ 52 NO MO • N ri'e w.,a r LST SR Cr" I IHKM IB16TM c 39 299 n No N0 (Inl tESI6N ALTIIAL C sD WW1 4t No NO _. Vi'-''': .,.... FROM TO IN IRI C 6 2S6i1 N NO NO t __- PISIII /0096 Z 7S [ SO 614 6 NO NO •� �9� IOS))6 705007 2 p5 C 50 7156 S NO NO �61�.. POEM IP1 2 320 C so CO 56 NO No ' r.r. �rrr�' xA`.a1 ma �`'- IM PM : W C SO MN 14 NO NO I (` m M2 t m C SO 21195 47 NO NO `-ATO Pp-8]9] 70 VT-81�J L-ATO PD-26 !0 PD-7R'.« --'TO PD-,816 . VT11 2 A TO PL--521.} WU V3 2 30 Ml PCB 2 10 WS POW 2 ffi I+v.8 .0_7 00-379/ n.r. Oil P0-28 t...e WL1T PU-78111 /n N 2 2M G "'$TING rTV, .r e'STING OPEN M POA13 2 SO pwrsv....'"10770:44 " Pa.ii.r..,. BOTTOM 4-Aar.s,.r 7 - u.,.a..u.� ..IP��w 80001? M NIS 2 ffi rD@nrI f..a>aa VAULT /�L°'^ VAULT ronr n.t !i' VAULT _.... ... - --.. ..s•u.s. IPI !01614 2 70- " r'.-w rw WI PO2 I ]iD PO2 !6 2 135 M6 PERM 2 is M6 M7 2 40 { •1111 ., „„. W7707125 : Y ..r..3, 7r _rw r. I M] vn9t : u9 M L..Ir r.•w Lir....... N. .... ft)v,-2�:-- —•'t1 Pl-R]„ 0On WO. 1j _irMOcYmo.i M —BTU P ,.J/ 'n Pn-2 TO vu-)Elti r 7010 6, •T.r/G0. r o MI ,_ ®� Taal len ILS o....00 .r. T.. +o PD-7915 MO A, r r' O ra. • N *� r EXISTING OPEN -".STING OPEN AM Or NIT•TN.. ` .r.mom.� Mm + �, RDTTnu •I P� BOTTOM ®P., ..r fir" - .DN.., i AIIL- r®..., --EL..... VAULT VAULT PRIMARY CABLE&CONDUIT TABLE r �. CONOIACAL.P. --54C.•.EILN0_,.--- IIT PNIMYIG'CAN25 ASNNLT NNPOM41LT1ON ILST S� 011' I Oum.EN. mem nNl suit GYNE DESIGN IEIIOTII - CAU 811 BEFORE YOU DIG {` I 1oe..A•GN.IN.14 ATTEN71ON' 811'. Tr- _ (inl OBION ACTUAL NEV OC31GN ACTUAL OREGON UWREOIIIRES YOU TO FOLLOW RUES ADOPTED MOM ro 191 IRI Ohl IIM1 S.6TYIx I01 MI 0002 THINK BY 7HE OREGON IMUTY NOTIFICATION CENTER. I • PL411 701296 A n u �Al.M 123 — 7NOSE RULES ARE SET PORIH IN OAR 952-001,010 1 { '1'1701X71/952401-0098.YW MAY OBTAIN COPES OF l..lrr..., ur.... L.ir.... P01716 PISA/ /1S 11 A nuEM 411 i S.�FET- PE RUES BY CALLING THE OREGONUD, �. 1 1 POSON) ►112 SW M u 12 ALM 161 FIRST! NOTIFICATION CENTER AOMV/IS103110N®(503-232458]) TO VT-814- „c. d;97 -o V:_'qK--- PO2 VM 710 41 41 nuUM MO ro0F>UFSr!/I0'Iry LOCATES CAI THE Out GUN II/.1 50.10/ 33./A PON CENTER V.I/30Vo I Cr 2.3011 you 014 W�r W Know whel'a beb.Y "11-]814 TO VT-81 r0 PD-]Bt6 V112 700 p 7 6 1200'EPR SII 2,,S,I.'ESE OA,PR',R TO EYCAVATIOn' P1S Pott ns 61 6 V ALCM 4u PGE CONSTRUCTION DRAWING vm P071113 !61 6 !t auv6 r '504-PGE VAULTWL5 VT-81 ,,.+w WL9 PD-7814 .. •-• 00761 Pu/+u as 76 A auIR OW SDPIWENG RENEW: IAS-BURT BY DESIGNER: 15�us.a N r O,5 N! EXISTING OPEN .. u;- EXISTING VAULT POAM Hu XII 41 53 GALE^' 7O I AS-BUILT VERIFICATION&NESC VIOLATIONS CORRECTED p a'o uR 11001 S � P ~' NEN. BOTTOM .•um.w..w.nn a Pal Poll. 17S A u aulM 411 �O / I vAUtr 'W" n>rfwt M WNI rivals 6'y yl 42 nuEPll i)0 Thedornmen1 eccucntay mnrn.cents FIELD cons Murton / -Q'"- 707125 VT101 300 2f a CAERA WO FOIemN1• Date: �. -�Y . l-. nu EPR GF: Defy. YY..IB.. �♦ 1.. nuc\� ------ nu EM ..EGF: ' NTS lAc.....1070001 IAN/'.:1000o0�J.....M2495679— 'a . ./I nuFM �1I.yyµµ66qpa� o• - - RAIN J Rl NJACKETED CABLE REPLACEMENT-DURHAM NORTH I.3,005ST PS.•Y'uEt:.c��ie J� � `I` RUEM `\ CSCUIT SOE /// I.•Ir r..., ` a .7 n u�N _ / \ DURHAM-SATTLER I 22%34 .-. `1 '1'-f/ nu1M �E LouTKw nuEM 9560 SW LAKESIDE DR.TIGARD.OR sc 4th MUS 1E06 rD VD-1 0 0D-/HI.'. T� GESCMPTNNN NPN N 12 SEGMENTS OF UNDERGROUND PRIMARY 'WAS rm.' N'glbP.wM 1.l ET 40100NLLf WASHINGTON C2111C,C21110 I- 7GF4 te.CEMER CESKW 8Y AAYIE OAAWN 6Y 9440 SW SOECIT/AIRO.PHIL MIERRIMAN 971.504.3579 1 KYLE LEM*TNEN NxSONV'''OR PAA 0 PORTLAND GENERAL ELECTRIC CO.-All maws RESERVED