Loading...
Report (64) Prescriptive Energy Code Compliance for All Climate Zones in Washington Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver, WA 98682 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb a n/a n/a Ceilingk 49' 0.026 Wood Frame Wall9' 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 30g 0.029 Below Grade Wall'' 10/15/21 int+TB 0.042 Slabd R-Value& Depth 10, 2 ft n/a "Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. [j2. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. 03. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. ❑4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope la 0.5 111 0.5 1b Efficient Building Envelope 1 b 1.0 ❑ 1c Efficient Building Envelope 1c 2.0 ❑ ld Efficient Building Envelope ld 0.5 ❑' 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 1.0 1.0 3b High Efficiency HVAC 3b 1.0 3c High Efficiency HVAC 3c 1.5 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 ❑ 5a Efficient Water Heating 5a 0.5 0 0.5 5b Efficient Water Heating 5b 1.0 ❑ 5c Efficient Water Heating 5c 1.5 1.5 5d Efficient Water Heating 5d 0.5 ❑ 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums.When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. Reserved. g Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter-or joist-vaulted ceilings, the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. Prescriptive Energy Code Compliance for All Climate Zones in Washington 'Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver, WA 98682 This project will use the requirements of the Prescriptive Path below and incorporate the the minimum values listed. In addition, based on the size of the structure,the appropriate number of additional credits are checked as chosen by the permit applicant. Authorized Representative Date All Climate Zones R-Valuea U-Factora Fenestration U-Factorb n/a 0.30 Skylight U-Factor n/a 0.50 Glazed Fenestration SHGCb e n/a n/a Ceilingk 49' 0.026 Wood Frame Wall9mn 21 int 0.056 Mass Wall R-Value' 21/21h 0.056 Floor 309 0.029 Below Grade Wand 10/15/21 int+TB 0.042 Slabd R-Value& Depth 10, 2 ft n/a *Table R402.1.1 and Table R402.1.3 Footnotes included on Page 2. Each dwelling unit in a residential building shall comply with sufficient options from Table R406.2 so as to achieve the following minimum number of credits: 1. Small Dwelling Unit: 1.5 credits ❑ Dwelling units less than 1500 square feet in conditioned floor area with less than 300 square feet of fenestration area. Additions to existing building that are greater than 500 square feet of heated floor area but less than 1500 square feet. [112. Medium Dwelling Unit: 3.5 credits All dwelling units that are not included in#1 or#3. Exception: Dwelling units serving R-2 occupancies shall require 2.5 credits. LLI3. Large Dwelling Unit: 4.5 credits Dwelling units exceeding 5000 square feet of conditioned floor area. [ ]4. Additions less than 500 square feet: .5 credits Table R406.2 Summary Option Description Credit(s) la Efficient Building Envelope la 0.5 0.5 1 b Efficient Building Envelope 1 b 1.0 ❑ lc Efficient Building Envelope lc 2.0 ❑ 1 d Efficient Building Envelope ld 0.5 ❑ 2a Air Leakage Control and Efficient Ventilation 2a 0.5 ❑ 2b Air Leakage Control and Efficient Ventilation 2b 1.0 ❑ 2c Air Leakage Control and Efficient Ventilation 2c 1.5 ❑ 3a High Efficiency HVAC 3a 1.0 [i 1.0 3b High Efficiency HVAC 3b 1.0 ❑ 3c High Efficiency HVAC 3c 1.5 ❑ 3d High Efficiency HVAC 3d 1.0 ❑ 4 High Efficiency HVAC Distribution System 1.0 ❑ 5a Efficient Water Heating 5a 0.5 0.5 5b Efficient Water Heating 5b 1.0 ❑ 5c Efficient Water Heating 5c 1.5 Li 1.5 5d Efficient Water Heating 5d 0.5 ❑ 6 Renewable Electric Energy 0.5 *1200 kwh 0.0 Total Credits 3.50 *Please refer to Table R406.2 for complete option descriptions Table R402.1.1 Footnotes For SI: 1 foot .= 304.8 mm, ci .= continuous insulation, int .= intermediate framing. a R-values are minimums. U-factors and SHGC are maximums. When insulation is installed in a cavity which is less than the label or design thickness of the insulation,the compressed R-value of the insulation from Appendix Table A101.4 shall not be less than the R-value specified in the table. b The fenestration U-factor column excludes skylights.The SHGC column applies to all glazed fenestration. "10/15/21.+TB" means R-10 continuous insulation on the exterior of the wall, or R-15 on the continuous insulation on the interior of the wall, or R-21 cavity insulation plus a thermal break between the slab and the basement wall at the interior of the basement wall. "10/15/21.+TB" shall be permitted to be met with R-13 cavity insulation on the interior of the basement wall plus R-5 continuous insulation on the interior or exterior of the wall. "10/13" means R-10 continuous insulation on the interior or exterior of the home or R-13 cavity insulation at the interior of the basement wall. "TB" means thermal break between floor slab and basement wall. d R-10 continuous insulation is required under heated slab on grade floors. See R402.2.9.1. e There are no SHGC requirements in the Marine Zone. Reserved. g Reserved. h Reserved. The second R-value applies when more than half the insulation is on the interior of the mass wall. Reserved. k For single rafter-or joist-vaulted ceilings,the insulation may be reduced to R-38. Reserved. m Int. (intermediate framing) denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. Table R402.1.3 Footnote a Nonfenestration U-factors shall be obtained from measurement, calculation or an approved source or as specified in Section R402.1.3. Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, some values will be calculated for you. If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver,WA 98682 Heating System Type: PiI Other Systems (Meat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions ( Design Temperature Difference(AT) 48 ✓ll 7.1 ift AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 2,687 Average Ceiling Height Conditioned Volume Instructions Average Ceiling Height(ft) 8.7 23,377 Glazing and Doors U-Factor X Area = UA Instructions 0.30 303 90.75 Skylights U-Factor X Area = UA Instructions 0.50 8 4.00 Insulation Attic U-Factor X Area = UA instructions eg 0.026 1,617 42.04 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA instructions „ ' ' r1No Vaulted Ceilings in the prole( r. '-- 0 Above Grade Walls(see Figure 1) U-Factor X Area UA Instructions r” 0.056 2,633 147.45 9 R 21•nteimedrate ",t. Floors U-Factor X Area UA InstructionsR $ "'" ' 0.025 1,643 41.08 Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions No Below Grade Jails in ths5 preject ♦a --- --- Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions No Slab Below Grade in this project Slab on Grade**Figure 1) F-Factor X Length UA Instructions --- reda No Slab on Diode In the project. ;," • J e " 99 7"uCtKtia ��mf9 Ri te -. Location of Ducts InstructionsDuct Leakage Coefficient Unconditioned Space V 1.10 Sum of UA 325.32 Envelope Heat Load 15,615 Btu/Hour Figure 1. Sum of UA X AT Air Leakage Heat Load 12,119 Btu/Hour VolumeX 0.6X AT X.018 £, Above Grade , Building Design Heat Load 27,734 Btu/Hour Air Leakage+Envelope Heat Loss Building and Duct Heat Load 30,507 Btu/Hour Ducts in unconditioned space:Sum of Building Heat Loss X 1.10 Ducts in conditioned space Sum of Building Heat Loss X 1 M xim m Heat E ui ment Output 42,710 Btu/Hour a uq p p Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Simple Heating System Size: Washington State This heating system sizing calculator is based on the Prescriptive Requirements of the 2015 Washington State Energy Code(WSEC)and ACCA Manuals J and S.This calculator will calculate heating loads only.ACCA procedures for sizing cooling systems should be used to determine cooling loads. The glazing(window)and door portion of this calculator assumes the installed glazing and door products have an area weighted average U-factor of 0.30. The incorporated insulation requirements are the minimum prescriptive amounts specified by the 2015 WSEC. Please fill out all of the green drop-downs and boxes that are applicable to your project.As you make selections in the drop-downs for each section, some values will be calculated for you.If you do not see the selection you need in the drop-down options,please call the WSU Energy Extension Program at(360)956-2042 for assistance. Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver,WA 98682 Heating System Type: (amu Other Systems Meat Pump To see detailed instructions for each section,place your cursor on the word"Instructions". Design Temperature Instructions ___ Design Temperature Difference(AT) 48 V a" ' ` ,a AT=Indoor(70 degrees)-Outdoor Design Temp Area of Building Conditioned Floor Area Instructions Conditioned Floor Area(sq ft) 2,687 Average Ceiling Height Conditioned Volume Inst uctior:s Average Ceiling Height(ft) 8.7 23,377 Glazing and Doors U-Factor X Area = UA Instructions 0.30 303 90.75 Skylights U-Factor X Area = UA Instructions 0.50 8 4.00 Insulation Attic U-Factor X Area = UA Instructions ae y,,' 0.026 1,617 42.04 Single Rafter or Joist Vaulted Ceilings U-Factor X Area UA Instructions t 0 No dacIted Cetengs an stes project ♦e;%' r ayY,",Fr1?j Above Grade Walls fsee Figure 1) U-Factor X Area UA Instructions t,tEnterneda¢e a+ 0.056 2,633 147.45 Floors U-Factor X Area UA Instructions R " r 0.025 1,643 41.08 Below Grade Walls(see Figure 1) U-Factor X Area UA Instructions t 'vo"'. No Below cmsde'Walls In t9s project V f --- --- Slab Below Grade(see Figure 1) F-Factor X Length UA Instructions Ivo Stab B ov.Grade in this project Slab on Grade(see Figure 1) F-Factor X Length UA Instructions ' No t ab on Grade in this project. Location of Ducts Instructions Duct Leakage Coefficient ` u G-ed,tioned Space ♦ 1.10 Sum of UA 325.32 Envelope Heat Load 15,615 Btu/Hour Figure 1. Sum of UA X AT .,- Air Leakage Heat Load 12,119 Btu/Hour VolumeX 0.6 XAT X.018 Above Grade Building Design Heat Load 27,734 Btu/Hour ., / .,—.,,.--,—,..-- Air Leakage+Envelope Heat Loss �n »•ri"`" Building and Duct Heat Load 30,507 Btu/Hour Ducts in unconditioned space Sum of Building Heat Loss X 1.10 Ducts in conditioned space:Sum of Building Heat Loss X1 Maximum Heat Equipment Output 42,710 Btu/Hour Building and Duct Heat Loss X 1.40 for Forced Air Furnace Building and Duct Heat Loss X 1.25 for Heat Pump (07/01/13) Window,Skylight and Door Schedule Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver,WA 98682 Width Height Ref. U-Factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door(24 sq.ft. max.) Manf. 0.50 1 3 0 6 8 20.00, 10.00 Exempt Glazed Fenestration(15 sq.ft. max.) 0.00 0.00 Vertical Fenestration(Windows and Doors) Component Width Height Description Ref. U-Factor Qt. Feet Inch Feet Inch Area UA Entry 0.28 1 4 6 1 0 4.50 1.26 Entry 0.28 1 1 0 5 6 5.50 1.54 Entry 0.28 2 2 0 2 0 8.00 2.24 Dining Room 0.28 1 5 0 2 0 10.00 2.80 Kitchen 0.28 2 3 0 4 0 24.00 6.72 Nook 0.28 1 6 0 7 10 47.00 13.16 Great Room 0.28 1 5 0 5 0 25.00 7.00 Great Room 0.28 2 2 0 2 0 8.00 2.24 Master Bedroom 0.28 2 2 6 4 0 20.00 5.60 Master Bedroom 0.28 1 3 0 4 0 12.00 3.36 Master Bedroom 0.28 3 2 0 2 0 12.00 3.36 Master Bath 0.28 1 5 0 2 0 10.00 2.80 Master Bath 0.28 3 2 6 3 0 22.50 6.30 W.I.C. 0.28 2 2 0 2 0 8.00 2.24 Bedroom#4 0.28 1 5 0 4 0 20.00 5.60 Bedroom#2 0.28 1 5 0 4 0 20.00 5.60 Bedroom#2 0.28 2 2 0 2 0 8.00 2.24 Bedroom#3 0.28 2 2 0 2 0 8.00 2.24 Bedroom#4 0.28 2 3 0 5 0 30.00 8.40 Sum of Vertical Fenestration Area and UA I 302.50 84.70 Vertical Fenestration Area Weighted U = UA/Area 0.28 Overhead Glazing(Skylights) Component Width Height Description Ref, U-Factor Qt. Feet Inch Feet Inch Area UA Sky Light Manf. 0.50 1 2 0 4 0 8.00 4.00 Manf. 0.50 0.00 0.00 Manf. 0.50 0.00 0.00 Manf. 0.50 0.00 0.00 Manf. 0.50 0.00 0.00 Sum of Overhead Glazing Area and UA 8.00 4.00 Overhead Glazing Area Weighted U = UA/Area 0.50 Total Sum of fenestration and UA(for heating system sizing calculations) 310.501 88.70 Window,Skylight and Door Schedule Project Information Contact Information Pacific Lifestyle Homes Ryan Styger 360.213.0839 11815 NE 99th St. Model: 2687 Milvio Vancouver,WA 98682 Width Height Ref. U-Factor Qt. Feet Inch Feet Inch Area UA Exempt Swinging Door(24 sq.ft. max.) Manf. 0.50 1 3 0 6 8 20.00 10.00 Exempt Glazed Fenestration(15 sq.ft. max.) 0.00 0.00 Vertical Fenestration(Windows and Doors) Component Width Height Description Ref. U-Factor Qt. Feet Inch Feet Inch Area UA Entry 0.28 1 4 6 1 0 4.50 1.26, Entry 0.28 1 1 0 5 6 5.50 1.54 Entry 0.28 2 2 0 2 0 8.00 2.24 Dining Room 0.28 1 5 0 2 0 10.00 2.80 Kitchen 0.28 2 3 0 4 0 24.00 6.72 Nook 0.28 1 6 0 7 10 47.00 13.16 Great Room 0.28 1 5 0 5 0 25.00 7.00 Great Room 0.28 2 2 0 2 0 8.00 2.24 Master Bedroom 0.28 2 2 6 4 0 20.00 5.60 Master Bedroom 0.28 1 3 0 4 0 12.00 3.36 Master Bedroom 0.28 3 2 0 2 0 12.00 3.36 Master Bath 0.28 1 5 0 2 0 10.00 2.80 Master Bath 0.28 3 2 6 3 0 22.50 6.30 W.I.C. 0.28 2 2 0 2 0 8.00 2.24 Bedroom#4 0.28 1 5 0 4 0 20.00 5.60 Bedroom#2 0.28 1 5 0 4 0 20.00 5.60 Bedroom#2 0.28 2 2 0 2 0 8.00 2.24 Bedroom#3 0.28 2 2 0 2 0 8.00 2.24 Bedroom#4 0.28 2 3 0 5 0 30.00 8.40 Sum of Vertical Fenestration Area and UA 1 302.50 84.70 Vertical Fenestration Area Weighted U = UA/Area 0.28 Overhead Glazing(Skylights) Component Width Height Description Ref. U-Factor Qt. Feet Inch Feet Inch Area UA Sky Light Manf. 0.50 1 2 0 4 0 8.00 4.00 Manf. 0.50 0.00 0.00 Manf. 0.50 0.00 0.00 Manf. 0.50 0.00_ 0.00 Manf. 0.50 0.00 0.00 Sum of Overhead Glazing Area and UA 8.00_ 4.00 Overhead Glazing Area Weighted U = UA/Area 0.50 Total Sum of fenestration and UA(for heating system sizing calculations) 310.501 88.70