Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Plans
BU P2017 - 003 11 2 0F 2 OFFICE COPY , ,., cry 0 ED D x 110 Li iii MILDREN DESIGN GROUP, P.C. ARCHITECTURE • SPACE PLANNING 7650 S.W. Beveland, Suite 120 Tigard, Oregon 97223-8692 (543) 244-4552 2 0 7 0 SW D ,a o aTfioQro or , 00n ,,e.,, ,. ,, ECEIVED Nov 30 2017 CITY OF TIGARD BUILDING DIVISION Code Analysis Sheet Index BASED ON THE 2012 INTERNATIONAL BUILDING CODE (IBC) WITH AO.1 COVER SHEET AND SITE PLAN 2014 OREGON STRUCTURAL AND SPECIALTY CODE AMENDMENTS A2.1 FLOOR PLAN A2.2 REFLECTED CEILING PLAN OCCUPANCY AND CONSTRUCTION PER OSSC 304 AND 311 OCCUPANCY: B CONSTRUCTION TYPE: III-B AVL" ``r> General Notes �`� "> FIRE-RESISTANCE RATING REQUIREMENTS: PER OSSC TABLE 601 AND 602 A. ALL HARDWARE IN ACCORDANCE WITH ANSI 117.1. 305. STRUCTURAL FRAME: 0 HRS. B. PROVIDE SIGN AT MAIN EXIT DOOR PER IBC 1008.1.8.3, 2.2 .'. tiii, ik”.31 EXTERIOR BEARING WALLS: 2 HRS. • STATING "THIS DOOR MUST REMAIN UNLOCKED WHEN BUILDING IS �IA��' `� ' - EXTERIOR NON-BEARING WALLS: 0 HRS. OCCUPIED". INTERIOR INTERIOR NON-BEARING WALLS: 0 HRS. 4 OF 16LFLOOR CONSTRUCTION: 0 HRS. Keynotes 0 -- �� C. NEW PAINT IN (2) COLORS THROUGHOUT WALLS TO RECEIVE 1' ROOF CONSTRUCTION: 0 HRS. LEVEL 4 FINISH : (1) COAT PRIMER, (2) COATS ACRYLIC LATEX. 1. EXISTING ACCESSIBLE PARKING STALL, AISLE AND SIGNAGE LEVEL OF GYPSUM BOARD FINISH TO BE PER ASTM C840. COLORS TO BE SELECTED BY TENANT. Client: BUILDING HEIGHT AND AREA PER OSSC TABLE 503 D. FURNISH THREE SILENCERS FOR SINGLE ACTING SINGLE DOORS; DO ALLOWABLE AREA: B: 19,000 SF NOT FURNISH SILENCERS FOR DOORS WITH WEATHERSTRIPPING OR CryoPDX ALLOWABLE HEIGHT: 2 STORIES GASKETING. ACTUAL BUILDING AREA: 27,200 SF n 0 \\\ \` / \\ / E. WOOD STUDS AT CONTRACTOR'S OPTION. ACTUAL HEIGHT: 1 STORY \ F. PROVIDE OUTSIDE AIR PER OCCUPANT PER MECHANICAL CODE. ti\ G. NEW CARPET AND 4" RUBBER BASE THROUGHOUT OFFICE. AREA MODIFICATION PER OSSC 506 \ `\ �\ H. HVAC TO REMAIN 1N WAREHOUSE. ] - `\` N. \ I. REPLACE STAINED AND BROKEN CEILING TILES AS REQUIRED. At=12,000sf, is-300 sprinkled one story, 1f-100[(F/P)-0.25](W/30), \\\\\- \ �, • J. RELOCATE LIGHTS AS REQUIRED FOR NEW WALL PLACEMENT. F=840 lineal feet, P=840 lineal feet, W=30, - 1. �� K. PROVIDE 1 APPROVED FIRE EXTINGUISHER WITH RATING OF NOT1128 NW 13th Ave. ( )1f-100[(355/710) 0.25](30/30) — .75, Aa=19000+[19000x.75X % ook\ 0 Portland, Oregon 97209 Aa=19000+14,250=33,250 SF c c\` .� LESS THAN 2-A: 10B FOR EACH 3,000 SQ.FT. OF FLOOR AREA g c\`\ TRAVEL FROM ANY PORTION OF BUILDING NOT TO EXCEED 75'. rcc, ' \ �� WHERE PROVIDED IN CIRCULATION PATH, FIRE EXTINGUISHERS Pro ect: FLAME SPREAD INDEX: PER OSSC SECTION 802 AND TABLE 803.9 % �� SHALL. BE PROVIDED IN SEMI-RECESSED CABINET. CABINET SHALL J1. 76-200 NOT PROJECT FROM WALL MORE THAN 4".opqAREA OF WORKT- SMOKE DEVELOPED INDEX: PER OSSC SECTION 802 AND TABLE 803.9 es4 ` • NOT MORE THAN 450 \\locos" for B OCCUPANCY: COMMON PATH OF EGRESS TRAVEL DISTANCE DOES NOT \` EXCEED 75'-O" PER OSSC SECTION 1014.3 % \i' •/ CryoPDX EXIT ACCESS TRAVEL DISTANCE DOES NOT EXCEED % \ \\�,\ 200'-0" PER OSSC SECTION 1016.2 \\ \ \ 14: • �, i 12070 SW Garden Place EGRESS ILLUMINATION: PER OSSC SECTION 1006 % \ p \ Deferred Submittals MEANS OF EGRESS, INCLUDING EXIT DISCHARGE, SHALL �•0 • Tigard, Oregon 97223 BE Ski • ILLUMINATED AT ALL MINIMUMS1 THE BLUMINATION AT •�� " -41 //t/Alle DOCUMENTS FOR DEFERRED SUBMITTAL ITEMS SHALL BE THE FLOOR LEVEL. a/'Q�enf�' , SUBMITTED TO THE REGISTERED DESIGN PROFESSIONAL IN Sheet Title: I�� \\:"Z‘:/. ; RESPONSIBLE CHARGE WHO SHALL REVIEW THEM AND FORWARD EMERGENCY LIGHTING: IN THE EVENT OF POWER SUPPLY FAILURE, AN l I aC@ `, \ / THEM TO THE BUILDING OFFICIAL WITH A NOTATION INDICATING EMERGENCY ELECTRICAL SYSTEM SHALL. AUTOMATICALLY # �� \ A THAT THE DEFERRED SUBMITTAL DOCUMENTS HAVE BEEN over Sheet ILLUMINATE THE PORTION OF THE EXTERIOR EXIT I I i‘ — • �� �\ / / REVIEWED AND BEEN FOUND TO BE IN GENERAL CONFORMANCE TO DISCHARGE IMMEDIATELY ADJACENT TO EXIT DISCHARGE giiiiik 1 �r \ ` . �Z THE DESIGN OF THE BUILDING. THE DEFERRED SUBMITTAL ITEMS DOORWAYS IN BUILDINGS REQUIRED TO HAVE TWO 0RI i I #.... .�\ SHALL NOT BE INSTALLED UNTIL THE DESIGN AND SUBMITTAL MORE EXITS WITH THE EXIT ILLUMINATION DOCUMENTS HAVE BEEN APPROVED BY THE BUILDING OFFICIAL. SUPPLEMENTED WITH AN EMERGENCY POWER SUPPLY1 4: . i ► NOTE: SUBMIT SHOP DRAWINGS FOR REVIEW OF DESIGN INTENT CAPABLE OF PROVIDING POWER FOR A DURATION OF ��\ ��� , COMPLIANCE PRIORTOFABRICATION OF THEFOLLOWING• NOT LESS THAN 90 MINUTES PER OSSC SECTION1006.3• ' 1. MECHANICAL DESIGN' I / 2. ELECTRICALDESIGNPLUMBING FIXTURES ,. Il 3. EGRESS ILLUMINATIONOCCUPANT LOAD PER OSSC TABLE 2902.1tail /B OCCUPANCY: 5,610 SF/100 = 56 PERSONS • � ' C' 0 ,� - .. - - ---, • .1- 4*- a - • OFF COPY28 MALE, 28 FEMALE , .• . > M/ k ",k�'d'i� 3 `� a r1>. -A'a -'^:� d r 7 '_,:` a r *3 r �r�. / a:=d' 1'7 t� r '� s ��*fix "�+ r z K. � �'_ •`,� �, t '' rte ° , , y, �� p�b t, Revisions:� t i . �'')� , CITY of TIGARD REQUIRED PROVIDED 4l4 ,...- •`� �, < •7 1 Il !I I 1 \ \ C J`� _ n.�, i11 a �`t(� _ w.,.„....•„,;,: !` �+�.t � kr g stt- EaA� °4f i • - A-3 ti� - ., _ RE►IEWED)FOR CODE COMPLIANCE LAVATORIES ` Pati mss'► `,. .�, r MALE 1 2 R' k f 'r1`N� � 3 � x' °y, Apjrovc 1 j :IvS�L� 1 1�\a FEMALE 1 2 ` g--„,'„,.- w�,! �� 1 WATER CLOSETS '4;tf: PPG l , r, . UTC. j MALE 1 2 ' Pcmat#: ag 5/Via! 7—c,1 iii FEMALE 1 Site Plan * Y � p �` p - x s 9 �0 4 ,~ SITE LOCATION 4" ' j r a , f�lc�ce" f ,`"0". 'rAL • r*-. 4 $al>Iid URINALS MALE 0 1 Mr r. A ' 0 30 60 120 = fir ' r,- " ,(e x } xtt , $fir, ---J. Date: 30- 2 SINKS 0 1 ' SW GARDEN PL °_:;1__,,::::::;:: , it'-:,,,,L-t.‹. ., ,• 5',,... ,„1 p'„ -,..,-,A,, ,, . --, : g� i 4 , w • - H.' �-V x'5' ,1 x� �, RIGHTSNRESERVEDQUP. P.C.: 2017. ALL WV ::':',.',''' x THESE DRAWINGS ARE THE PROPERTY OF s �� y �; y Nti ' i ac p MILDREN DESIGN GROUP, P.C., AND ARE 5 _ ,,, ' r , 4 ,,, A" NOT TO BE USED OR REPRODUCED 1N ANY G x '� -a .' 4 f ',. } MANNER, EXCEPT WITH THE PR[OR WRITTEN .1., Fav1:1 , ft PERMISSION OF MILDREN DESIGN GROUP, P.C. " 3 � ,!,.!:-1,11 Date: 22 November 2017 1� -it r F« L N"- ' -' � _ Drawn by: Checked by: i BK WEM 'ik� 3 ,-tV_ 'A'4',itt .- .'M.. - z.- , ..Ar X5,5 .' `.�� Job Number: 117190 'TY OF TiGARDA- Vicinity Map Sheet Approved b Ian Ing Date: 11 3o11l N.T.S. initials: �''' g_IF ;� Permit Submittal - November 2017 AO. 1 h,---4..„.......„ 4 6 8 Door Schedule Keynotes }' �. NOMINAL SIZE FRAME DOOR HARDWARE REMARKS 1. NEW WALL FLUSH WITH EXISTING MARKWIDTH HEIGHT THICK. MAT'L FINISH MAT'L FINISH TYPE GROUP 2. EQUIPMENT BY TENANT MILDREN DESIGN GROUP, P.0 ARCHITECTURE • SPACE PLANNIN( 108 3'–0" 7'–0" 1-3/4" MTL FF SC ST A 1 7650 S.W. Beveland, Suite 120 109 3'–O" T-0" 1-3/4" MTL FF SC ST A 1 Tigard, Oregon 97223-8692 (503) 244-0552 LEGEND FF FACTORY FINISH MTL METAL A - _____ P PAINT SC SOLID CORE ST STAIN Finish Schedule ROOM NAME Door Hardware Floor Finish N.- A4BB9 X. EXISTING TO REMAIN GROUP 1 1i PAIR BUTTS 1 LOCKSET Base 1 GASKET B C 1 STOP 4" RUBBER BASE X. EXISTING TO REMAIN Skg) ill/PC 1 Wall Finish 305. =� --CIE), L , E tiR.)l T I ;\� A. GYPSUM BOARD AND PAINT •, II ,' EXISTING ! EXISTING, OFFICE EXISTING OFFI E Door Type X. EXISTING TO REMAIN -'1.1 , ti 4 TREATMENT ! EXISTING CeilingFinish '� RM. ! C' 5 BREAK RM. . 4' OF 0 � -z�E -r\ i X. EXISTING TO REMAIN (--- -4;.„) EXIT TRAVEL DISTANCE=79'-3" TREATMENT RM. 1 ( . Client: 108 XX i! - _ _ - \ Ceiling Height EXISTING 111.04 S.F. 1! Da { CryoPDX X. EXISTING TO REMAIN TREATMENT I /100 = 1.11 i (,::-::::: I �r RM. \ B:EXITS 1 6:-. co, \ I ' --4-Ti 4 DF Df - = j0 x w }- t, f OPEN EXISTING OFFICE EXISTING (3 ° EXISTING o j1 ' f--- --1 ,-N- A l , WOMEN MEN EXISTING — 8~ l L– IT �� 2 1128 NW 13th Ave. TREATMENT Wall Legend Portland, Oregon 97209 L i L J RM. r -I / { EXISTING WALL TO REMAIN L J a2.I - - NEW WALL TO BOTTOM OF CEILING Project: �-0 Ail T.I. NITR•GEN/STORAGE for 140A XJX XX Symbol Legend CryoPDX 96.32 S.F. y g /10C = 0.96 . . . B:EXITS 1 101 NEW DOOR 12070 SW Garden Place EXISTING EXISTING DOOR Tigard, Oregon 97223 PHYSICAL THERAPY RM. TOP TO ST (1) 20 GA. 3/$" NOMINAL METAL STUD BRACING TO STRUCTURE ABOVEWHERE IS LESSOF THANWALL 5'-9" PROVIDERUCTURE (1) BRACE AT 8'–O" 0/C TO ONE Sheet Title: WITH (2) #8 SHEET METAL SIDE ONLY, STAGGER SIDES. WHERE SCREWS AT EACH END; PROVIDE Floor Plan 1 DOUBLE STUD BRACE WHEN N /1DISTANCE IS GREATER THAN 5'-9", ,\ DISTANCE TO STRUCTURE ABOVE >i I \ / I PROVIDE BRACES EACH DIRECTION AT / IS GREATER THAN 5'-9". BRACING EXISTING V I ti / 8'-0" 0/C TO BE PROVIDED WHERE DISTANCE 4+ ELECTRIC RM. I / 7 / \ BETWEEN PERPENDICULAR / INTERSECTING WALLS OR I / \ HORIZONTAL BRACING BETWEEN \ WALLS EXCEEDS 8'-0" (DO NOT © r EXTEND BRACING INTO EXPOSED I 1 - 1 STRUCTURE AREAS) L 1%2" x 1%2" x 16 GA x 1 ;7 3" WITH 4 8 SCREWS � ) # ,4/110 SUSPENDED CEILING Revisions: r EACH SIDE f- 24" 0/C STUD CHART: 140-T-t CASING BEAD USG 200–A • 362 S 125-18 TO 9'-3" ATTACH STUD TRACK �_ I • 362 S 137-33 TO 17'-6" TO BRACING THROUGH 11 • 400 S 162-33 TO 19'-10" OVERSIZED HOLE IN �! 5/s„ GYPSUM BOARD EACH SIDE • 600 S 162-33 TO 25'-1" SECURE TO STUDS WITH TYPE 'S' GRID SCREWS AT 5" - 7" 0/C iiiit r �''. NOTES: Floor Plan } ` 4111), SEE DETAIL 2/A2.1 FOR STUD • SEE AVE FOR ALTERNATE SIZES HART • ALLOWABLE HEIGHTS BASED ON 5 PSF LATERAL LOAD, 1/120 glir C DEFLECTION, NON–COMPOSITE, FULLY BRACED CONDITION. SEE 0 2 4 8 16 3 " SOUND ATTENUATION BATT DETAILS FOR FULLY BRACED 4" RUBBER BASE _...... • VALUES BASED ON AISI S100-07 WITH SUPPLEMENT S2-10 AS TYPICAL '`�� REFERENCED BY 2014 IBC • STUDS AS MANUFACTURED BY SCAFCO STEEL STUD COMPANY POWER–ACTUATED FASTENERS: OR APPROVED EQUAL , AD MILDREN DESIGN GROUP, P.C.. 2017, ALL •0.145"o x " MIN. EMBED AT 12" 0/C WALL TO 22'-0" RIGHTS RESERVED THESE DRAWINGS ARE THE PROPERTY OF •0.145"� x " MIN. EMBED AT MILDREN DESIGN GROUP, P.C., AND ARE 6" 0/C, WALL TALLER THAN NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITEN 22'-0" PERMISSION OF MILDREN DESIGN GROUP,P.C. 1 Wall to Suspended Ceiling 2 Stud Height Chart Date: 22 November 2017 3"=1'–O„ A2.1 1 a1 d–r8 ~�.� Stud Height Cart Drawn by: Checked by: BK WEM Job Number: 117190 Sheet Permit Submittal - November 2017 A2. 1 4 6 8 Keynotes MILDREN DESIGN GROUP, RC 1. EXISTING SUSPENDED CEILING AND LIGHTS ARCHITECTURE ■ SPACE PLANNIM 2. EXISTING GYPSUM BOARD AND LIGHTS TO REMAIN 7650 S.W. Beveland, Suite 120 Tigard, Oregon 97223-8692 (503) 244-0552 A , I I Electrical Symbols ,....,... EXISTING 2x4 FLUORESCENT LAY—IN FIXTURE WITH B , ........ PARABOLIC LENS <OD ARC EXISTING 2—TUBE CHAIN HUNG FLUORESCENT OR LED LIGHTS I---il ,I______it 11---t I U-----1 1 VERIFY MOUNTING HEIGHT WITH TENANT , FT- — ----1 C j.\\ r I- EN 0 EXISTING EXHAUST FAN, CEILING MOUNTED, VENTED THROUGH ROOF , , = OF 7 ---- f[ n /6 __ an,43._________ ti _ , - 4110 0 EXISTING LIGHTED EXIT SIGN — . _ ,-- _ . . _I--, Client: D MU IIIIIII BM MU IN CryoPDX .___. . .... , ,, .., ... ... . . " . . [-. _ , • ... ______ .,, . 1128 NW 13th Ave .. . , . ... . . . . _._ • NB at : . , , . . ...• , . . • . .._ - ,___ : - 0- . . . . . . 1 CI Portland, Oregon 97209 . — — - , — - Project: II , T.I. Ir-11 , L. • for . _ _ CryoPDX I- - - - _ _ , D I . _ — ___ — — 12070 SW Garden Place D Tigard, Oregon 97223 — — — — — — Sheet Title: _ _ _ _ I — , Reflected - _ Ceiling Plan ._; _ . 1 0 I JI — ANNEM---11111111.111ii. 1 .__ I I_ " Revisions: At Reflected Ceiling Plan lip 0 2 4 8 16 MILDREN DESIGN GROUP, P.C., 2017, ALL RIGHTS RESERVED 0 THESE DRAWINGS ARE THE PROPERTY OF MILDREN DESIGN GROUP, P.C., AND ARE NOT TO BE USED OR REPRODUCED IN ANY MANNER, EXCEPT WITH THE PRIOR WRITTEN PERMISSION OF MILDREN DESIGN GROUP, P.C. Date: 22 November 2017 Drawn by: Checked by: BK WEM Job Number: 117190 Sheet Permit Submittal - November 2017 A2.2